Você está na página 1de 3

Lighting

MASTER HPI-T Plus


MASTER HPI-T Plus 400W/645 E40 1SL/12
Quartz metal halide lamps with clear outer bulb

Product data

General Information Operating and Electrical


Cap-Base E40 [ E40] Power (Rated) (Nom) 382 W

Operating Position P20 [ Parallel +/-20D or Horizontal(HOR)] Lamp Current Run-Up (Max) 6A

Life to 5% Failures (Nom) 5000 h Lamp Current (EM) (Nom) 3.4 A

Life to 10% Failures (Nom) 7500 h Ignition Supply Voltage (Max) 198 V

Life to 20% Failures (Nom) 11000 h Ignition Supply Voltage (Min) 198 V

Life to 50% Failures (Nom) 20000 h Ignition Time (Max) 10 s

System Description Horizontal Operating Position Voltage (Max) 135 V

Voltage (Min) 115 V

Light Technical Voltage (Nom) 125 V

Color Code 645 [ CCT of 4500K]

Luminous Flux (Rated) (Min) 30000 lm Controls and Dimming


Luminous Flux (Rated) (Nom) 32000 lm Dimmable No

Color Designation Cool White (CW)

Lumen Maintenance 10000 h (Nom) 70 % Mechanical and Housing


Lumen Maintenance 2000 h (Min) 75 % Bulb Finish Clear

Lumen Maintenance 2000 h (Nom) 90 %

Lumen Maintenance 20000 h 60 % Approval and Application


Lumen Maintenance 5000 h (Min) 65 % Energy Efficiency Label (EEL) A+

Lumen Maintenance 5000 h (Nom) 80 % Mercury (Hg) Content (Nom) 29.5 mg

Chromaticity Coordinate X (Nom) 361 Energy Consumption kWh/1000 h 420 kWh

Chromaticity Coordinate Y (Nom) 372

Correlated Color Temperature (Nom) 4500 K Luminaire Design Requirements


Luminous Efficacy (Rated) (Nom) 84 lm/W Bulb Temperature (Max) 600 °C

Color Rendering Index (Nom) 65 Cap-Base Temperature (Max) 250 °C

Datasheet, 2018, May 14 data subject to change


MASTER HPI-T Plus

Product Data Numerator - Packs per outer box 12

Full product code 871150020345815 Material Nr. (12NC) 928481600092

Order product name MASTER HPI-T Plus 400W/645 E40 1SL/12 Net Weight (Piece) 0.210 kg

EAN/UPC - Product 8711500203458

Order code 928481600092

Numerator - Quantity Per Pack 1

Warnings and Safety


• Use only in totally enclosed luminaire, even during testing (IEC61167, IEC 62035, IEC60598)
• The luminaire must be able to contain hot lamp parts if the lamp ruptures
• For use with control gear designed for high-pressure mercury or sodium lamps
• A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove
the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a
vacuum cleaner.

Dimensional drawing

D Product D (max) O L C (max)

MASTER HPI-T Plus 400W/645 E40 1SL/12 47 mm 30.5 mm 168 mm 286 mm


O

C
L

HPI-T Plus 400W/645 E40

Photometric data

210° 180° 150° 210° 180° 150° 600


[μW / (m2 . 5nm . 1000 lux)]

500
240° 120° 240° 120°
400

270° 100 50
90° 270° 100 50
90° 300

200

300° 60° 300° 60° 100

330° 0° 30° 330° 0° 30° 300 400 500 600 700 λ[nm]

HPI-T MASTER HPI-T Plus

Datasheet, 2018, May 14 2 data subject to change


MASTER HPI-T Plus

Lifetime

Lumen in %
100 100
Survival in %

90 90

80 80

70 70

60 60
50 50
0 5000 10000 15000 20000 0 5000 10000 15000 20000
Burning hours Burning hours

HPI-T Life Expectancy HPI-T Lumen Maintenance

© 2018 Philips Lighting Holding B.V. All rights reserved. Philips Lighting reserves the right to make changes in specifications

and/or to discontinue any product at any timewithout notice or obligation and will not be liable for any consequences resulting www.lighting.philips.com

from the use of this publication. 2018, May 14 - data subject to change