Você está na página 1de 4

TOTAL CONTROL

TEMPERATURE HUMIDITY HYGIENE AIR MOVEMENT IAQ

TOTAL CLIMATE CONTROL BY


CARYAIRE SYSTEMS
Total Conditioning Systems (TCS) that Integrates HVAC Solutions to Provide Year Round Performance.
• Independent control of temperature, humidity, filtration, purification, air movement, fresh air and noise levels.
• Year round operation
• Flexibility
• Highly Energy efficient
• Fully functional with all controls
• Meets IAQ requirements

Individual, Custom-Specific, Optimum “HVAC“ Solutions.


Systems for applications around the world that require air ambience adjusted to specific customer needs within the defined parameters of
temperature, humidity, cleanliness, movement, IAQ, noise, and energy recoveries.

A Completely New Innovation.


Units with built-in and non overlapping controls of one or more functions of cooling / heating / humidification / dehumidification to provide a
single solution to your air conditioning requirements.
• Very high & consistent comfort levels
• Fully factory assembled (no site work)
• Low Energy consumption
• Excellent price/quality ratio
• Reduced installation time on-site & costs
• Reduced maintenance costs

Design Your Unit Range


• Modular construction • Delivered air flow rate : 1000 – 50000 cmh
• Advanced housing design • Air temperature : -10 deg. C to 70 deg C (consistency up to +- 0.2 C)
• Double wall construction • Air humidity : <1% to 90% RH (consistency up to +-1 %)
• Cold bridge free • Plenum design : up to +- 2000 Pa
• Energy performance standards • Outdoor air ratio : up to 100%
• Insulation choice • Energy recoveries : up to 85% (sensible & latent)
• Custom options

Mechanical Characteristics Compliant Rating and Performance Compliant to EN 13053


to EN 1886 • Air flow
• Pressure
• Thermal transmittance : Class T2 • Electrical power input
• Thermal bridge : Class TB2 • Heating & cooling capacity
• Casing leakage : Class B • Heat recovery
• Filter bypass leakage : Class F9
• Casing strength : Class 1A, 2A • Sound power
Industrial Applications
Food
Biscuit manufacturing; cookie drying; fruit / vegetables dehydration; dried milk powder conveying, packing;
chewing gum mfg.; brewery; chocolate mfg.; confectionary; cold rooms; sugar conveying; yeast making

Pharmaceuticals
Soft gelatine capsules drying, tablet coating, capsule filling, strip packing, effervescent tablets/powders,
ampicillin mfg. areas, vitamin tableting & packing

Paper & Printing


Library, archives storage, gravure printing, currency printing, paper & fibre molding, paper storage, pulp and
paper pre-conditioning

Electrical & Electronics


Filament winding capacitor winding, high voltage transformer mfg., compressor assembly-white rooms, glove
box for thermal battery

Glass
Automotive / Construction Glass Lamination

Corrosion prevention
Storage of military equipment, power plant lay up, Tyre creel rooms, Electronics production and storage, Water
treatment facilities.

Product drying
Candy coating, Yeast production, Fruit and vegetable processing, Plastic resin molding

Moisture Regain Prevention


Pharmaceutical processing, Storage and Packaging, Candy Production and Packaging.

Mold and Fungus Prevention


Schools and Universities, Restaurants, Breweries, Hospitals, Archive Storage, Seed Storage.

Condensation Prevention
Ice skating rinks, Injection molding, Plastic extrusion, Blow molding operations, Water treatment facilities

Marine | Clean Rooms | Semi conductor | Defence | Power | Dry Storage | Super stores| Recreations
Dairies | Corrosion | Cold Rooms | Product drying | Hospitals | Water Damage| Construction | Hotels |
Indoor Stadiums | Manufacturing | Optical | Leather | Textiles | Plastics & Rubber | Fertilizer | Museums
& Archive | Breweries | Chemical plants | Tea / Coffee| Seeds | Laboratories Preservation

CARYAIRE FOR EVERY INDUSTRY


PHARMA | FOOD | ELECTRONICS | OPTICAL | AGRICULTURE | STORAGE
Total Conditioning Systems of Highest Quality at a Competitive Cost
CASING: Al or steel frame with double skin galvinized, painted, stainless steel or aluminium sheets.
Options: Weather proof / Hygienic.
FAN: Aerofoil, Backward inclined, Forward curved or Radial.
FILTRATION: EU2 thru EU13.
COOLING: Refrigerant, Chilled water, Chilled brine.
HEATING: Electric, Hot water, Steam, Thermic fluid, LPG/CNG.
DEHUMIDIFICATION: Refrigeration/Desiccant.
HEAT RECOVERY: Rotary, Plate, Heat pipe, Coil-loop recovery.

DEHUMIDIFIER SECTION
BLOWER SECTION

POST COOL SECTION

POST FILTER
SECTION

PRE FILTER SECTION


ENTHALPY RECOVERY

HEATER SECTION

COIL SECTION

ACCESS SECTION

Caryaire Equipments India Pvt. Ltd Mumbai Office Bangalore Office


A-10, Sector 59, NOIDA - 201 301(U.P) 207, Blue Rose Industrial Estate, No. 452, 11th Main, 23rd Cross,
India Off Westren Express Highway, Sector - 7, HSR Layout,
Tel :+91 120 2580553, 54, 55, 56 Borivli (E) MUMBAI - 400 066, India Bangalore - 560 034
Fax :+91 120 2580557 Tel :+91 22 55702056, 557002057 Tel :080 - 25727830 / 1
Email :sales@caryaire.com Fax :+91 22 28547314 Fax :080 - 25727833
Web :www.caryaire.com Email :mumbai@caryaire.com Email :caryaireblr@vsnl.net

Você também pode gostar