Você está na página 1de 26

FSR-13

I. PILING ....................................................................................................... 14

II. EXCAVATION............................................................................................ 16

III. CONCRETE WORK .................................................................................. 18

IV. BRICKWORK AND BLOCKWORK........................................................... 23

V. ROOFING .................................................................................................. 24

VI. STRUCTURAL STEELWORK AND METALWORK.................................. 24

VII. WALL & FLOOR FINISHES ...................................................................... 28

VIII. PAINTING .................................................................................................. 29

IX. DRAINAGE WORK .................................................................................... 31

X. ROADS AND PAVING ............................................................................... 34

XI. OTHER EXTERNAL WORKS AND SERVICES ........................................ 36

2017 ISSUE CONTRACT RC111


FSR-14
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

I. PILING

A. TIMBER PILES

1. Bakau Piles
Supply and drive bakau pile
a) 75mm diameter ne 5.00m long No 15.00
b) 75mm diameter 5.00 - 10.00m long, including mild steel
pipe sleeves No 26.15

2. Mattress Piles
Supply and lay bakau roller
a) 75mm diameter m 4.05

B. CONCRETE PILES

1. Precast Concrete Piles


Supply and drive precast concrete pile complying with SS CP 4
a) 155 x 155mm cross-section m 30.45
b) 180 x 180mm cross-section m 34.60
c) 205 x 205mm cross-section m 38.40
d) 230 x 230mm cross-section m 42.85
e) 260 x 260mm cross-section m 50.20
f) 285 x 285mm cross-section m 55.05
g) 305 x 305mm cross-section m 63.70

C. STEEL PILES

1. Isolated Piles
Supply and drive steel 'H' piles complying with BS EN 10029, with corrosion
protection including extension by weld jointing
a) size 203 x 203mm x 53.57 kg/m m 143.65
b) size 254 x 254mm x 62.50 kg/m m 167.35
c) size 305 x 305mm x 78.87 kg/m m 204.00
d) size 330 x 330mm x 108.63 kg/m m 275.95
e) size 356 x 356mm x 132.44 kg/m m 326.40

2017 ISSUE CONTRACT RC111


FSR-15
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

D. BORED PILES

1. Grade 35 Concrete Piles


Supply and install bored cast in place concrete piles including temporary steel
casing (reinforcement measured separately)
a) diameter 500mm m 134.75
b) diameter 600mm m 148.65
c) diameter 900mm m 242.60
d) diameter 1200mm m 389.55
e) diameter 1500mm m 476.40
Supply and install bored cast in place concrete piles (temporary steel casing and
reinforcement measured separately)
f) diameter 500mm m 129.70
g) diameter 600mm m 142.75
h) diameter 900mm m 235.75
i) diameter 1200mm m 379.25
j) diameter 1500mm m 466.10

2. Grade 40 Concrete Piles


Supply and install bored cast in place concrete piles including temporary steel
casing (reinforcement measured separately)
a) diameter 500mm m 138.85
b) diameter 600mm m 159.60
c) diameter 900mm m 258.75
d) diameter 1200mm m 399.15
e) diameter 1500mm m 490.75
Supply and install bored cast in place concrete piles (temporary steel casing and
reinforcement measured separately)
f) diameter 500mm m 133.70
g) diameter 600mm m 157.25
h) diameter 900mm m 253.65
i) diameter 1200mm m 391.45
j) diameter 1500mm m 482.50

3. Steel Casing
a) Supply and drive steel casing to be left in for bored piles kg 2.60

2017 ISSUE CONTRACT RC111


FSR-16
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

E. MICROPILES

1. Bored Micropiles
Supply and install micropiles
a) 150mm diameter m 226.90
b) 200mm diameter m 257.65
c) 250mm diameter m 280.95
Cutting of pile to the required level including welding of the bearing plate
d) generally No 243.40

2. Driven Micropiles
Supply and drive steel micropiles complete with cement grouting to centre void
a) 114mm diameter (with working capacity of 20 ton each) m 96.45
Cutting of pile to the required level including welding of the bearing plate
b) Generally No 106.80

F. SUNDRIES

1. Pile Tests
Test loading of piles with the Kentledge reaction system including casting and
subsequent removal of temporary pile cap
a) generally t 69.45

II. EXCAVATION

A. SITE CLEARANCE

1. Clear Site Vegetation


Clear bushes, shrubs, undergrowth, saplings, grass, rubbish and small trees not
exceeding 600mm girth including grubbing up roots, filling voids and disposal of
materials off site
a) generally m2 3.00

2. Remove Trees
Cut tree including grubbing up roots, filling voids and disposal of materials off site
a) 600 - 1000mm girth No 347.70
b) 1000 - 1500mm girth No 585.30
c) 1500 - 2000mm girth No 911.65
d) 2000 - 2500mm girth No 1,136.95

2017 ISSUE CONTRACT RC111


FSR-17
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

3. Oversite Excavation
Excavate over site, commencing from ground level, to reduce level
a) average 100mm deep m2 2.90
b) average 200mm deep m2 3.50
c) average 300mm deep m2 4.05
d) 300 - 1000mm deep m3 10.85

B. GENERAL EXCAVATION

1. Pit/Trench Excavation
Excavate to form trench, commencing from reduced level
a) ne 1.00m deep and cross sectional area ne 0.50m2 m 10.30
Excavate to form pit or trench, commencing from reduced level
b) ne 2.00m deep m3 19.35
c) 2.00 - 4.00m deep m3 28.65
d) 4.00 - 5.00m deep m3 40.95

2. Basement Excavation
Excavate to form basement, commencing from reduced level
a) ne 2.00m deep m3 18.05
b) 2.00 - 4.00m deep m3 25.15

3. Cutting
Excavate to form embankment, commencing from reduced level
a) generally m3 17.60

4. Break Up Obstructions
Extra over excavation for breaking up obstruction using mechanical means
a) brickwork and blockwork m3 30.15
b) mass concrete m3 47.05
c) reinforced concrete m3 96.10
d) rock m3 140.20

5. Break Up Surface Obstructions


Break up surface pavement
a) tarmacadam surface m3 26.95
b) mass concrete m3 52.10
c) reinforced concrete m3 100.70
d) brickwork and blockwork m3 34.25

2017 ISSUE CONTRACT RC111


FSR-18
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

Cut surface pavement using pavement diamond cutter to achieve a straight edge
e) ne 150mm deep m 18.75

C. FILLING

1. Backfilling
Backfilling around trench, column base, pile cap, foundation beam and pier hole
a) excavated material obtained within the site m3 6.20
b) earthfilling obtained from contractor's own source m3 18.80

2. Filling and Forming Embankments


Deposit, spread, level, compact and consolidate in layers of 150mm thick to make
up levels
a) excavated material obtained within the site m3 8.35
b) earthfilling obtained from contractor's own source m3 21.70

3. Hardcore and Aggregate


Spread, level, compact, ram and consolidate
a) hardcore, including blinding with sand m3 71.35
b) quarry waste m3 73.20
c) quarry dust (aggregate size 5mm down) m3 65.45
d) granite aggregate, including blinding with quarry waste m3 79.75
e) unwashed sand m3 51.40

D. DISPOSAL

1. Excavated Material
Remove excavated material off site
a) for suitable excavated material m3 14.60
b) for unsuitable excavated material m3 32.10

III. CONCRETE WORK


A. IN-SITU CONCRETE

1. Lean/Mass Concrete
Lean or Mass concrete complying with BS EN 1992-1-1
a) grade 10 m3 142.65
b) grade 15 m3 144.80
c) grade 20 m3 150.00

2017 ISSUE CONTRACT RC111


FSR-19
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

2. Reinforced Concrete
Reinforced concrete complying with BSEN 1992-1-1
a) grade 20 m3 151.35
b) grade 25 m3 154.15
c) grade 30 m3 156.85
d) grade 35 m3 159.00
e) grade 40 m3 162.80
f) grade 45 m3 166.65
g) grade 50 m3 171.35
h) grade 55 m3 178.40

3. Waterproofed Concrete
Waterproofed concrete complying with BSEN 1992-1-1 with approved waterproofing
compound
a) grade 30 m3 217.95
b) grade 35 m3 227.50

B. REINFORCEMENT

1. Bar Reinforcement
Mild steel bar reinforcement complying with SS 560
a) 6mm diameter kg 1.80
b) 10mm diameter kg 1.70
c) 13mm diameter kg 1.70
d) 16mm diameter kg 1.65
e) 20mm diameter kg 1.65
f) 22mm diameter kg 1.65
g) 25mm diameter kg 1.65
h) 28mm diameter kg 1.65
i) 32mm diameter kg 1.65
High tensile steel bar reinforcement complying with SS 560
j) 10mm diameter kg 1.60
k) 13mm diameter kg 1.55
l) 16mm diameter kg 1.55
m) 20mm diameter kg 1.55
n) 22mm diameter kg 1.55

2017 ISSUE CONTRACT RC111


FSR-20
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

o) 25mm diameter kg 1.55


p) 28mm diameter kg 1.55
q) 32mm diameter kg 1.55
r) 40mm diameter kg 1.55
s) 50mm diameter kg 1.65

2. Fabric Reinforcement
Welded steel fabric reinforcement complying with SS 561 and well lapped
(measured nett)
a) Reference No A5 m2 5.05
b) Reference No A6 m2 6.15
c) Reference No A7 m2 7.35
d) Reference No A8 m2 9.05
e) Reference No A9 m2 10.90
f) Reference No A10 m2 12.40
g) Reference No B5 m2 7.75
h) Reference No B6 m2 8.60
i) Reference No B7 m2 9.60
j) Reference No B8 m2 12.00
k) Reference No B9 m2 13.80
l) Reference No B10 m2 15.80
m) Reference No B11 m2 18.05
n) Reference No B12 m2 20.60
o) Reference No B13 m2 20.95
p) Reference No D6 m2 9.85
q) Reference No D7 m2 12.20
r) Reference No D8 m2 15.40
s) Reference No D9 m2 18.95
t) Reference No D10 m2 23.05
u) Reference No D11 m2 27.50
v) Reference No D12 m2 32.40

2017 ISSUE CONTRACT RC111


FSR-21
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

C. PRECAST CONCRETE

1. Kerb or Divider
Precast concrete kerb or divider in Grade 25 concrete including laying in alignment
and finishing fair on all exposed surfaces
a) 125 x 250mm Type K2A Kerb m 17.00
b) 125 x 275mm Type K2B Kerb m 17.25
c) 150 x 300mm Type D1 Divider m 16.45
Extra over Type K2A/B Kerb with slot hole
d) generally No 4.30

2. Cover Slab
Precast concrete Grade 30 cover slab all as detailed in SDRE – Drains & Culverts
a) 640 x 270 x 75mm No 11.45

D. FORMWORK

1. Sawn Formwork
Sawn formwork to in-situ concrete including strutting not exceeding 3.5m high
a) curved surface m2 44.55
b) plain surface m2 38.50

2. Wrought Formwork
Wrought formwork to in-situ concrete including strutting not exceeding 3.5m high
a) curved surface m2 52.90
b) plain surface m2 48.20

3. Strutting
Extra over for strutting exceeding 3.50m high
a) Every 1.50m high m2 5.45

E. WATER PROOFING TO CONCRETE

1. Damp Proof Membrane


Waterproofing sheet laid to top, side or underside of concrete structure
a) Medium weight (Basic wt: 280g/m2) approved building
paper m2 5.45
b) Heavy weight (Basic wt: 527g/m2) approved building
paper m2 5.95

2017 ISSUE CONTRACT RC111


FSR-22
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

2. Water-stops
PVC water-stop embedded in concrete at interfaces of structural elements
a) 200mm wide m 26.65
b) 250mm wide m 36.85

3. Protection
Polystyrene board fixed to external surface of concrete
a) 25mm thick, 16 kg/m3 grade m2 10.50

F. SUNDRIES

1. Expansion Joints
75mm high bitumen impregnated fibreboard joint filler
a) 12mm thick m 3.15
b) 20mm thick m 3.70
c) 25mm thick m 4.45
Polyethylene bond breaking strip to joint
d) 10mm diameter m 3.05
e) 15mm diameter m 3.40
f) 25mm diameter m 3.75
25mm wide polysulphide sealer to joint
g) 15mm deep m 18.15
h) 25mm deep m 29.30
15mm wide x 50mm deep heavy duty approved sealant
i) generally m 16.50
15mm wide x 175mm deep impregnated flexcell board
j) generally m 12.00

2. Trowelling
Labour trowel top surface of concrete to a smooth finish including additional cement
a) generally m2 7.35

3. Cutting To Concrete
Labour in cutting reinforced concrete to form groove not exceeding 100mm wide
including rendering with cement mortar (1:3)
a) ne 50mm deep m 9.20
b) 50 - 100mm deep m 17.70

2017 ISSUE CONTRACT RC111


FSR-23
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

4. Demolition
Break up existing concrete structure including cutting and bending reinforcement
and removal of debris off site
a) opening ne 0.10 m3 No 66.55
b) opening 0.10 - 0.20m3 No 91.25
c) opening exceeding 0.20m3 m3 441.95

IV. BRICKWORK AND BLOCKWORK

A. CLAY BRICKS

1. Common Brickwork (Standard Size)


Common brick (standard size 215 x 102.5 x 65mm) in cement mortar (1:4) with
mortar plasticiser
a) Half brick thick wall m2 37.10
b) One brick thick wall m2 70.25

B. CONCRETE BLOCKS

1. Hollow Blockwork
Hollow concrete block complying with SS271 : 1983 in cement mortar (1:4) with
mortar plasticiser
a) 75mm thick wall m2 23.85
b) 100mm thick wall m2 25.95
c) 150mm thick wall m2 34.35

C. GLASS BLOCKS

1. Walls/Panels
Glass block in wall or panel in cement mortar (1:4) with mortar plasticiser
a) 150 x 150 x 100mm thick m2 403.75
b) 190 x 190 x 100mm thick m2 307.55

2017 ISSUE CONTRACT RC111


FSR-24
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

V. ROOFING

A. BUILT-UP ROOFING

1. Felt Roofs
Bituminous felt roofing on flat roof including sealing and bonding
a) 1-ply felt; 17.75 kg per 20m2 m2 30.75
b) 2-ply felt; 35.50 kg per 20m2 for each layer m2 55.85
c) 3-ply felt; first and second layers each weighing 27 kg
per 20m2 and third layer weighing 45 kg per 20m2 m2 73.65

150mm high bituminous felt skirting including sealing and bonding


d) 1-ply felt; 17.75 kg per 20m2 m 14.30
e) 2-ply felt; 35.50 kg per 20m2 for each layer m 35.10
f) 3-ply felt; first and second layers each weighing 27 kg
per 20m2 and the third layer weighing 45 kg per 20m 2 m 41.35

B. PROFILED SHEET ROOFING OR CLADDING

1. Steel Deckings
High tensile profile patent Colorbond/colorcote with zincalume coating roof or wall
cladding fixed to steel or timber framing (measured separately) with fixing clips and
self-tapping screws
a) 0.47mm thick sheet m2 41.95
b) 0.53mm thick sheet m2 46.95

VI. STRUCTURAL STEELWORK AND METALWORK

A. STRUCTURAL STEELWORK

1. Mild Steel Members


Mild steel member complying with BSEN 10029 in stanchion, beam, girder, roof
truss, purlin, cleat and bracket
a) solid section kg 5.70
b) hollow section kg 5.90

2017 ISSUE CONTRACT RC111


FSR-25
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

B. METALWORK

1. Mild Steel Members


Mild steel flat, rod, angle, channel, baluster and rail complying with BSEN 10029
a) generally kg 5.90

2. Mild Steel Plain Bolts


Mild steel plain bolts complying with BS 4190 including head, nut and washer
a) 12mm diameter grade 8.8 black bolt, ne 75mm long No 2.70
b) 12mm diameter grade 8.8 black bolt, 75 - 150mm long No 3.25
c) 12mm diameter holding down bolt, 300mm long
including grouting No 17.75

3. Mild Steel Galvanised Bolts


Mild steel galvanised bolt complying with BS 4190 including head, nut and washer
a) 12mm diameter grade 8.8 bolt, ne 75mm long No 2.35
b) 12mm diameter grade 8.8 bolt, 75 - 150mm long No 2.75
c) 12mm diameter holding down bolt 300mm long including
grouting No 17.80

C. VEHICULAR IMPACT GUARDRAIL

1. Vehicular Impact Guardrail


Hot dip galvanised vehicular impact guardrail fixed to steel channel post (post and
support measured separately) including bolt and nut as per SDRE – Guardrails
a) W-Beam 311 x 83 x 3mm m 100.10
b) Turned-down anchorage Type A – (4.05m long) with
post and concrete as per SDRE – Guardrails No 686.55

2. Post and Support


Post and spacer block with galvanised bolt and nut including concrete foundation, all
necessary excavation, and disposal of excavated material.
a) 150 x 110 x 18 x 4.3mm Hot dip galvanised channel
post cast in concrete foundation as per SDRE – Guardrails Set 150.45
b) 150 x 110 x 18 x 4.3mm Hot dip galvanised channel
post mounted on concrete structure including slip base plate
as per SDRE – Guardrails Set 277.85

2017 ISSUE CONTRACT RC111


FSR-26
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

Hot dip galvanised brace support (on one side) including post, spacer, brace with
mild steel plates welded, set in and including concrete foundation, all necessary
excavation, disposal of excavated material as per SDRE – Guardrails
c) 150 × 150 × 6mm SHS Set 453.40

3. End terminal
Design, supply and install end terminal complete with end terminal, post, support,
foundation, cable-anchor assembly, W-beam and all necessary fixings as per SDRE
– Guardrails
a) Type B - 10.1m long cable anchored terminal as per
SDRE – Guardrails Set 11,143.10
b) Thrie-Beam Transition consisting of thrie-beam
transition section, thrie-beam and end piece Set 6,611.10
Design, supply and install crash cushion in compliance with NCHRP 350 Test
complete with end terminal, post, support, foundation, W-beam and all necessary
fixings as per SDRE – Guardrails
b) Crash cushion Set 46,161.00

D. RAILING

1. Aluminium Alloy Railing


Aluminium alloy railing in powder coating finish consisting of tubular or square hollow
section set in and including concrete foundation, all necessary excavation and
disposal of excavated material from site as per SDRE – Railings
a) Type A m 224.15
b) Type B m 199.20
c) Type C m 162.95
d) Type D m 207.20
e) Type E m 180.00
f) Type F m 150.00

2017 ISSUE CONTRACT RC111


FSR-27
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

E. GRATING

1. Pedestrian Grating
Mild steel grating in panels consisting of 80 x 38 x 4.6mm galvanised steel angle
frame, with 35 x 9mm galvanised mild steel flat all round, in filled with 25 x 5mm
galvanised mild steel flat, all joints and intersections whole welded, drilled and
including painting with one coat of inhibitive primer before delivery and built into
concrete surround including 3mm thick mild steel plate ≤ 3mm thick anti-slip coating,
and mild steel angle frame with 2mm thick polyurethane sound damper as per SDRE
– Gratings & Manhole Covers
a) generally m2 413.35

2. Vehicular Grating
Mild steel grating in panels consisting of 100 x 75 x 9.4mm thick galvanised angle
frame with 65 x 9mm fish-tailed mild steel flat welded at 30mm centres and infilled
with 12mm diameter mild steel bars at 85mm centres, all joints and intersections
whole welded, drilled and including painting with one coat of inhibitive primer before
delivery, built into concrete surround as per SDRE – Gratings & Manhole Covers
a) generally for drains m2 1,284.35

Mild steel grating in panels consisting of 100 x 100 x 10mm thick galvanised mild
steel angle frame with fish-tail mild steel flat welded and infilled with 25 x 6 mild steel
flat at 30mm centres and 90 x 22mm mild steel flat at 85mm centres. The complete
assembly except fishtails are to be hot-dipped galvanised. All the flats and angles
are to be fillet welded throughout and drilled before delivery, built into concrete
surround as per SDRE – Gratings & Manhole Covers.
b) generally for manholes m2 1,256.60

3. Aluminium Rung
300 x 230mm aluminium rung as per SDRE – Drains & Culverts fixed to concrete
wall in drain including drilling and grouting with cement mortar (1:3)
a) 25mm diameter No 22.75

F. SURFACE TREATMENT

1. Hot Dip Galvanising


Hot dip galvanising complying with ISO 1460 and ISO 1461 to structural steelwork
a) generally kg 1.75

2. Powder Coating Finish


Powder coating finish to metalwork complying with BS 4842
a) General Surfaces m2 16.25

2017 ISSUE CONTRACT RC111


FSR-28
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

b) Pipes, bars, angles not exceeding 100mm girth m 1.90


c) Ditto exceeding 100mm and not exceeding 200mm girth m 2.70
d) Ditto exceeding 200mm and not exceeding 300mm girth m 3.45

VII. WALL & FLOOR FINISHES

A. WALL & FLOOR FINISHES

1. Smooth Finished Plaster


Cement and sand (1:4) plaster mixed with mortar plasticiser to concrete or brick
surface including trowelling smooth
a) 13mm thick m2 19.00
b) 20mm thick m2 24.10
Cement and Sand (1:3) plaster mixed with mortar plasticiser and waterproofing
compound to concrete or brick surface including trowelling smooth
c) 13mm thick m2 20.95
d) 20mm thick m2 24.10

2. Plain Paving
Cement and sand (1:3) paving including trowelling smooth
a) average 20mm thick m2 15.00
b) average 25mm thick m2 17.40
c) average 32mm thick m2 18.55
20mm thick cement and sand (1:3) skirting with splayed or rounded top edge and
coved bottom including trowelling smooth
d) 100mm high m 7.00
e) 150mm high m 7.75

3. Hardened Paving
25mm thick cement and sand (1:3) paving mixed with hardener including trowelling
smooth
a) light duty non-metallic hardener (3kg per m2) m2 25.55
b) heavy duty non-metallic hardener (7kg per m2) m2 33.95

4. Granolithic Paving
Granolithic aggregate paving consisting of cement, sand and granite chippings of
5mm gauge (2:1:5) set out in panels with 15 x 15mm deep recessed joints laterally
at 1.20m centres including scrubbing to produce exposed aggregate finish
a) 25mm thick m2 40.00

2017 ISSUE CONTRACT RC111


FSR-29
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

b) 32mm thick m2 43.00


c) 40mm thick m2 45.90

5. Screed Bed
Cement and sand (1:3) screed to receive floor finishes
a) 20mm thick m2 16.00
b) 25mm thick m2 16.80
c) 32mm thick m2 17.50

VIII. PAINTING

A. PAINTING

1. Concrete or Plastered Surfaces


Painting concrete or plastered surface and the like
a) one coat of oil based anti-alkali sealer, one undercoat
and two finishing coat of acrylic emulsion paint m2 10.00

2. Timber Surfaces
Painting timber surface
a) two coats of aluminium wood primer m2 6.45
b) two coats of stain and two coats of wax polish m2 9.20
c) two coats of varnish m2 10.00
d) one coat of aluminium wood primer, one undercoat and
two finishing coats of enamel paint m2 12.40

3. Metal Surfaces
Painting metal surface
a) one coat anti-rust paint, one undercoat and two coats of
aluminium paint m2 15.45
b) one coat of zinc chromate primer, one undercoat and
two finishing coats of synthetic enamel paint m2 15.25

4. Road Marking
One coat of 1.5mm thick thermoplastic paint on road pavement as per SDRE –
Road Markings & Signs
a) 100mm wide line m 6.15
b) 150mm wide line m 9.20
c) 200mm wide line m 12.45
d) 300mm wide line m 17.10

2017 ISSUE CONTRACT RC111


FSR-30
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

e) exceeding 300mm wide line m2 48.50


One coat of 3.0mm thick thermoplastic paint on road pavement as per SDRE –
Road Markings & Signs
f) 100mm wide line m 13.70
g) 150mm wide line m 19.45
h) 200mm wide line m 27.45
i) 300mm wide line m 35.50
j) 455mm wide line m 54.50
k) exceeding 455mm wide line m2 124.25
l) go-straight arrow No 241.90
m) go-straight with right/left turn arrow No 278.75
n) right/left turn arrow No 270.00
o) merge arrow No 283.05
p) triple-head arrow No. 357.25
q) multi-head arrow for turning movements (3 lanes) No. 1,965.00
r) multi-head arrow for turning movements (4 lanes) No. 2,175.00
One coat of 5.00mm thick thermoplastic paint on road pavement as per SDRE –
Road Markings & Signs
s) 200mm wide line m 41.75
Raised profile markings (8mm thick) including 3.00mm thick thermoplastic paint on
road pavement as per SDRE – Road Markings & Signs
t) 200mm wide m 20.40
u) 300mm wide m 28.65
Non-skid yellow colour coating for Mandatory Give Way Bus Zone as per SDRE –
Road Markings & Signs
v) generally m2 53.75
8mm thick thermoplastic paint regulating strips on road pavement as per SDRE –
Traffic Management Measures
w) 300mm wide m 85.50
Erase existing thermoplastic road lines and markings including clearing all shavings
and making good
x) generally m2 20.00

2017 ISSUE CONTRACT RC111


FSR-31
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

IX. DRAINAGE WORK

A. DRAINAGE WORK

1. Drain Excavation
Excavate trench minimum 340mm wide for 100mm diameter pipe, not exceeding
2.00m deep including backfilling and disposal of surplus excavated material
a) average 600mm deep m 17.05
b) average 1000mm deep m 24.25
c) average 1500mm deep m 50.70
Excavate trench minimum 490mm wide for 150mm diameter pipe including
temporary supports, backfilling and disposal of surplus excavated material
d) ne 2.00m deep, average 1.50m deep m 49.60
e) 2.00 - 4.00m deep, average 3.00m deep m 72.90

2. Benchings & Haunchings


125mm thick concrete (Grade 35) bed under 250mm UPVC scupper pipe including
haunching to half height of pipe carried up and splayed tangentially and all
necessary formwork, reinforcement and lean concrete
a) 450mm wide, under 250mm diameter scupper pipe m 51.40

B. SUB-SOIL PIPES OR DRAINS

1. UPVC Pipes
Heavy duty unplasticised polyvinyl chloride Class C subsoil pipes 3/4 perforated
a) 100mm diameter m 31.85
b) 150mm diameter m 52.15

2. Filling Materials
a) Graded stone 20mm size m3 126.00

3. Drainage Layer
a) Geocomposite drainage layer as per SDRE – Drains &
Culverts m2 10.65

2017 ISSUE CONTRACT RC111


FSR-32
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

C. PRECAST CONCRETE CULVERTS

1. Pipe Culverts
Precast concrete pipe culverts Class 'L' complying with SS 183 butt jointed with
cement and sand (1:1) mortar
a) 300mm diameter m 50.35
b) 450mm diameter m 92.80
c) 600mm diameter m 138.95
d) 750mm diameter m 210.25
e) 900mm diameter m 264.20
f) 1,050mm diameter m 309.75
g) 1,200mm diameter m 376.75
h) 1,350mm diameter m 460.50
i) 1,500mm diameter m 577.20
Precast concrete pipe culverts Class 'M' complying with SS 183 butt jointed with
cement and sand (1:1) mortar
j) 300mm diameter m 75.55
k) 450mm diameter m 107.45
l) 600mm diameter m 151.75
m) 750mm diameter m 242.30
n) 900mm diameter m 314.75
o) 1,050mm diameter m 409.50
p) 1,200mm diameter m 438.50
q) 1,350mm diameter m 548.25
r) 1,500mm diameter m 699.20

D. PRECAST CONCRETE DRAINS

1. Base Section of 'U' Drain


Precast concrete 'U' drain base section laid to even falls and jointed in cement and
sand (1:3) mortar, internal size
a) 600 x 600mm m 172.60
b) 750 x 600mm m 199.50
c) 900 x 600mm m 243.65
d) 1,050 x 600mm m 290.00
e) 1,200 x 600mm m 355.75

2017 ISSUE CONTRACT RC111


FSR-33
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

2. Composite Channels
Precast concrete composite channel or block drains laid to even falls and jointed in
cement and sand (1:3) mortar
a) Type C1 m 7.95
b) Type C2 m 8.55
c) Type C3 m 10.70
d) Type C4 m 11.75
e) Type C5 m 12.70
f) Type C5A m 13.40
g) Type C6 m 19.15
h) Type C7R m 31.45
i) Type C7R1 m 33.30
j) Type C7A m 19.50
k) Type C7B m 19.35
l) Type C8 m 84.85
m) Type C8A m 63.55
n) Type C8B m 67.60
o) Type B1 m 22.80
p) Type B2 m 25.20
q) Type B3 m 67.55
Precast concrete channel laid in precast 'U' drain base sections or precast concrete
culverts including concrete grade 20 benching
r) Type C3 m 20.00

3. Scupper Drain and Pipe


Scupper drain or pipe laid to even falls jointed in cement and sand (1:3) mortar
a) Type S1 drain m 34.45
b) 250mm diameter UPVC Pipe to SS141 m 31.15
c) 250mm diameter heavy duty UPVC pipe class AW m 66.20

4. Weepholes
Supply and fix UPVC pipe to SS141 as weephole
a) 65mm diameter ne 300mm long No 2.95
b) 65mm diameter exc 300mm long m 4.50
c) 75mm diameter ne 300mm long No 3.20
d) 75mm diameter exc 300mm long m 5.20

2017 ISSUE CONTRACT RC111


FSR-34
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

E. SUNDRIES

1. Drop Inlet Chamber


Precast concrete drop inlet chamber including hot dip galvanised mild steel framing
and grating laid on compacted sub-base and including forming proper connection to
scupper pipe as per SDRE – Drains & Culverts
a) 750 x 300 x 325mm Internal size No 254.80

2. Sump
Precast concrete sump for sub-soil drain including proper connections, concrete
benching and precast concrete cover slabs, internal size
a) 550 x 550 x 1300mm No 523.25

X. ROADS AND PAVING

A. PAVEMENT

1. Sub-base
Supply and lay Sub-base material
a) generally m3 70.45

2. Base Course
Supply and lay Coarse granite aggregate (crusher-run) base course and blinded with
fine aggregate
a) generally m3 116.85
Supply and lay Graded granite aggregate base course
b) generally m3 93.55
Supply and lay Recycled concrete aggregate base (RCA) base
c) generally m3 50.00

3. Asphalt Concrete
Supply and lay hot-mix asphalt concrete base, binder or wearing course including
soluble bitumen
a) mix-specification type B1 ton 116.25
b) mix-specification type B1G ton 121.25
c) mix-specification type W1 ton 118.00
d) mix-specification type W3 ton 118.00
e) mix-specification type W3B ton 116.25
f) mix-specification type Open-graded ton 141.20

2017 ISSUE CONTRACT RC111


FSR-35
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________
Supply and lay hot-mix asphalt concrete binder course mix type B1 including soluble
bitumen
g) 50mm (consolidated) thick m2 14.20
h) 75mm (consolidated) thick m2 21.05
i) 90mm (consolidated) thick m2 25.15
j) 120mm (consolidated) thick m2 33.40
Supply and lay hot-mix asphalt concrete binder course mix type B1G including
soluble bitumen
k) 75mm (consolidated) thick m2 19.75
l) 90mm (consolidated) thick m2 23.65
m) 120mm (consolidated) thick m2 31.60
Supply and lay hot-mix asphalt concrete wearing course mix type W3B including
soluble bitumen
n) 25mm (consolidated) thick m2 7.35
o) 40mm (consolidated) thick m2 11.70
p) 50mm (consolidated) thick m2 14.30
Supply and lay hot-mix open graded asphalt concrete special road mix including
modified binder
q) 25mm (consolidated) thick m2 8.00
r) 40mm (consolidated) thick m2 12.25
s) 50mm (consolidated) thick m2 15.30

4. Sundries
Brush, sweep and thoroughly clean to remove all loose and superfluous materials
and ensure a perfectly dry surface prior to the application of the tack coat and
asphalt concrete
a) existing bitumen or concrete surfaces m2 0.35
Supply and lay tack coat of bitumen emulsion sprayed at a rate of 0.54 litre per m2
b) existing bitumen or concrete surfaces m2 0.95

2017 ISSUE CONTRACT RC111


FSR-36
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

XI. OTHER EXTERNAL WORKS AND SERVICES

A. STREET FURNITURE

1. Directional Signs
Single-face directional signs comprising aluminium sheeting 14SWG laminated with
approved reflective sheeting including all the required size of letters, numbers, logo(s)
and all necessary backings, welding and other types of connections as per SDRE –
Supports for Road Signs (supports to be measured separately)
a) Micro Prismatic Reflective Grade m2 1,061.35
Supports including foundation, excavation and disposal as per SDRE – Supports for
Road Signs
b) 75mm diameter cantilever supports (Type A) No 649.75
c) a pair of 100 x 100 x 6mm SHS supports (Type B) No 3,952.65
d) a pair of 120 x 120 x 8mm SHS supports (Type C) No 7,682.50
e) a pair of 150 x 150 x 6mm SHS supports (Type D) No 8,171.00

2. Traffic Signs
Single-faced silk screen traffic signs as regulatory signs, warning signs and
informative signs comprising 2mm thick aluminium sheets, approved Micro Prismatic
Grade reflective sheetings including appropriate diagrams, alphabets and numerals
(supports to be measured separately)
a) size 600 x 450mm No 214.00
b) size 600 x 600mm No 266.00
c) size 900 x 900mm No 411.05
d) other sizes m2 503.70
Supports for traffic signs
e) Supply and install 50 x 50 x 2.3mm thick galvanised square
hollow section vertical supports of traffic signs to all details as
shown in SDRE – Supports for Road Signs including excavation,
if any, and disposal of excavated materials from site, fixing and
fastening of maximum three traffic signs on any one face per
support, using 400 x 400 x 400mm concrete foundation with
built in expansion bolts No 133.15

3. Curved Alignment Marker

Curved alignment marker comprising of 2mm thick aluminium sheets and approved
Mirco Prismatic Fluorescent Yellow reflective sheetings as per SDRE – Road
Markings and Signs
a) size 600 x 750mm (for arterial road) No 317.50
b) size 750 x 900mm (for expressway) No 510.00

2017 ISSUE CONTRACT RC111


FSR-37
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

B. SUNDRIES

1. Turfing
Turfing consisting of grass, size 300 x 300mm not less than 50mm thick, including
50mm thick topsoil and sludge (3:1) top dressing
a) spot turf on horizontal surface m2 8.30
b) close turf on embankment exceeding 15º from the
horizontal m2 9.90

2. Pipes For Street Lighting


Excavation for concrete foundation, disposal of excavated materials from site,
concrete foundation shall be measured separately.
Pipe crossing complete with pilot fish wire excluding long bends.
a) 75mm diameter medium duty galvanised iron pipe m 40.65
b) 75mm diameter heavy duty galvanised iron pipe m 46.20
c) 75mm diameter Class AW heavy duty PVC pipe m 15.65
d) 75mm diameter Class B heavy duty PVC pipe m 11.15
e) 100mm diameter medium duty galvanised iron pipe m 54.20
f) 100mm diameter heavy duty galvanised iron pipe m 59.50
g) 100mm diameter Class AW heavy duty PVC pipe m 23.35
h) 100mm diameter Class B heavy duty PVC pipe m 11.95

3. Geotextile Membrane
Approved synthetic geotextile fabric membrane to pavement, troughs, french drains
etc. well lapped at joint (measured nett)
a) Type Class A m2 4.00
b) Type Class B m2 2.80

4. Tree Aeration Trough


Excavation for tree aeration trough, disposal of excavated materials from site,
250mm diameter UPVC scupper pipe as shown in SDRE – Planting Requirement
shall be measured separately.
Tree aeration trough consisting of 20mm granite aggregate wrapped around with
approved synthetic geotextile fabric membrane complete with 100mm diameter
perforated UPVC pipes complete with cover and galvanised steel clearing plate
welded to 10mm diameter mild steel rod, as per SDRE – Planting Requirement
a) 2000 x 2000 x 700mm No 494.65

2017 ISSUE CONTRACT RC111


FSR-38
ITEM DESCRIPTION UNIT RATE ($)
_______________________________________________________________________________________________________________

5. Paving Slabs
Precast concrete (grade 20) paving slab jointed and pointed in cement and sand (1:3)
including 50mm thick sand bed
a) size 300 x 300 x 50mm thick m2 55.65

6. Aeration Slabs
Precast concrete aeration slab of any pattern with top soil and turfing in voids
including 50mm thick sand bed
a) 65mm thick m2 46.50
b) 100mm thick m2 52.05

2017 ISSUE CONTRACT RC111

Você também pode gostar