Você está na página 1de 248

Model 101

Load Cell
DESCRIPTION
Model 101 load cells is engineered to measure bending
forces and still achieve an impressive 0.02 % accuracy. Small
dimensions allow easy unit integration into existing systems.
Model 101 uses foil gages and is available for load ranges from
50 grams to 1000 pounds.

FEATURES
• 50 kg to 1000 kg range
• ±0.02 % accuracy
• Integral cable
• Cost efficient
• One-piece, nickel-plated alloy steel construction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 101

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Codes Range
Load ranges 3
50, 100, 250, 500, 1000 kg LF 50 kg
Accuracy ±0.02 % full scale LH 100 kg
Output 2 mV/V (nominal) LL 250 kg
Creep (max.) ±0.02 % full scale (30 minutes) LN 500 kg
LQ 1000 kg

ENVIRONMENTAL SPECIFICATIONS
MOUNTING DIMENSIONS
Characteristic Measure
Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F] Load (kg) H mm [in] Recommended bolt
torque (N-m)
Temperature, compensated -20 °C to 55 °C [-4 °F to 130 °F]
50 to 2250 18 [0.71] 60
Temperature effect, zero 0.02 % full scale/10 °C
500, 1000 24 [0.94] 60
Temperature effect, span 0.02 % full scale/10 °C

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc to 12 Vdc
Excitation (max.) 15 Vdc
Insulation resistance >5000 mOhm
Bridge resistance (toler- 400 ohm ±10 ohm (nominal)
ance) - input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) 3 m flying leads

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % full scale1
Material Nickel plated alloy steel
Deflection < 2 mm

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large black shield

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 101 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage2. Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift of performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit is calibrated to Metric (non-Imperial) units.
or replace, at its option, without charge those items it finds
TYPICAL SYSTEM DIAGRAM defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008674-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 102
Load Cell
DESCRIPTION
The Model 102 load cells combines both a compact form and
high precision to offer a superior tension force transducer. The
one-piece S-shaped design achieves a maximum non-linearity
of 0.02 % full scale for load ranges from 20 kg to 1000 kg.
Additional features include minimal temperature effects on zero
and span of 0.002 %/°C and 0.002 %/°C, respectively.

FEATURES
• 20 kg to 1000 kg range
• ±0.02 % accuracy
• One-piece, nickel-plated alloy steel construction
• Integral cable
• Cost efficient

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 102

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 3
20, 50, 100, 200, 300, 500, 1000 kg LD 20 kg
Accuracy ±0.02 % full scale LE 30 kg
Output 2.0 mV/V LF 50 kg
Creep (max.) ±0.02 % full scale (30 minutes)
LG 75 kg
LH 100 kg
ENVIRONMENTAL SPECIFICATIONS
LJ 150 kg
Characteristic Measure
LK 200 kg
Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F]
LL 250 kg
Temperature, compensated -20 °C to 55 °C [-4 °F to 131 °F]
LM 300 kg
Temperature effect, zero ±0.02 % full scale/10 °C
LN 500 kg
Temperature effect, span ±0.02 % full scale/10 °C
Protection class IP67 LQ 1000 kg

ELECTRICAL SPECIFICATIONS MOUNTING DIMENSIONS


Characteristic Measure Load D (thread) L
Strain gage type Bonded foil 20 kg to 150 kg M8 x 1.25 12 mm [0.47 in]
Excitation (acceptable) 10 Vdc to 12 Vdc 200 kg to 500 kg M12 x 1.75 20 mm [0.79 in]
Excitation (max.) 15 Vdc 700 kg to 1000 kg M12 x 1.75 25 mm [0.98 in]
Insulation resistance > 5000 mOhm
Bridge resistance (toler- 400 ohm ±10 ohm (nominal)
ance) - Input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - Output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) 3 m [9.84 ft] flying leads

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 full scale1
Material Nickel plated alloy steel or stainless
steel
Deflection Less than or equal to 0,5 mm [0.02 in]

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large Black Shield

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 102 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit is calibrated to Metric (non-Imperial) units.
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008662-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 103
Load Cell
DESCRIPTION
Model 103 load cell is engineered to measure bending forces
and still achieve an impressive 0.02% full scale accuracy. Small
dimensions allow easy unit integration into existing systems.
Model 103 uses foil gages and is available for load ranges from
100 kg to 10000 kg.

FEATURES
• Low cost
• 100 kg to 10000 kg range
• ±0.02 % accuracy
• Integral cable
• Cost efficient
• One-piece, nickel-plated alloy steel construction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 103

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Codes Range
Load ranges 3
100, 200, 300, 500, 1000, 2000, 3000, LH 100 kg
5000, 10000 kg
LL 250 kg
Accuracy ±0.02 % full scale
LM 300 kg
Output 2 mV/V (nominal)
LN 500 kg
Creep (max.) ±0.02 % full scale (30 minutes)
LQ 1000 kg

ENVIRONMENTAL SPECIFICATIONS LS 2000 kg

Characteristic Measure LU 5000 kg

Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F] LW 10000 kg

Temperature, compensated -20 °C to 55 °C [-4 °F to 130 °F]


Temperature effect, zero ±0.02 % full scale/10 °C TYPICAL SYSTEM DIAGRAM
Temperature effect, span ±0.02 % full scale/10 °C

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc to 12 Vdc
Excitation (max.) 15 Vdc
Insulation resistance >5000 mOhm
Bridge resistance (toler- 400 ohm ±10 ohm (nominal)
ance) - input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) 3 m flying leads
100 kg to 300 kg
Electrical termination (std) 5 m flying leads
1000 kg to 5000 kg
Electrical termination (std) 8 m flying leads
10000 kg

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % full scale1
Material Nickel plated alloy steel
Deflection < 1,5 mm

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large black shield

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Load Cell

MOUNTING DIMENSIONS
Load A mm B mm C mm D mm E mm F mm G mm H mm L mm M mm Recom-
(kg) [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] mended
bolt
torque
(N-m)
100 to 135 [5.31] 36 [1.42] 26 [1.02] 18 [0.71] 75 [2.95] 25 [1.0] 32 [1.26] 58 [2.28] 11,5 11,5 60
300 [0.45] [0.45]
500 to 135 [5.31] 38 [1.5] 30 [1.18] 18 [0.71] 75 [2.95] 25 [1.0] 34 [1.34] 58 [2.28] 13,5 13,5 100
2000 [0.53] [0.53]
300 to 170 [6.69] 48 [1.89] 38 [1.5] 20 [0.79] 85 [3.35] 50 [2.0] 39 [1.54] 79 [3.11] 18 [0.71] 18,5 255
5000 [0.73]
10000 263 60 [2.36] 60 [2.36] 30 [1.18] 118 [4.65] 90 [3.54] 52 [2.05] 134 [5.28] 26 [1.02] 26 [1.02] 860
[10.35]

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 103 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage2. Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift of performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit is calibrated to Metric (non-Imperial) units.
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008675-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 123
Load Cell
DESCRIPTION
The Model 123 load cells combines both a compact form and
high precision to offer a superior tension force transducer. The
one-piece S-shaped design achieves a maximum non-linearity of
0.03 % full scale for load ranges from 1000 kg to 20000 kg.

FEATURES
• 1000 kg to 20000 kg range
• ±0.03 % accuracy
• Built-in overload resistance
• One-piece, nickel-plated alloy steel construction
• Integral cable
• Cost efficient

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 123

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 4
1000 kg to 20000 kg LQ 1000 kg
Accuracy ±0.03 % full scale LR 1500 kg
Output 2.0 mV/V LS 2000 kg
Creep (max.) ±0.03 % full scale (30 minutes)
LT 3000 kg
LU 5000 kg
ENVIRONMENTAL SPECIFICATIONS LV 7500 kg
Characteristic Measure LW 10000 kg
Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F]
LY 15000 kg
Temperature, compensated -20 °C to 55 °C [-4 °F to 131 °F]
LZ 20000 kg
Temperature effect, zero ±0.03 % full scale/10 °C
Temperature effect, span ±0.03 % full scale/10 °C
Protection class IP673 MOUNTING DIMENSIONS
Range (kg) A B C D
ELECTRICAL SPECIFICATIONS 1000, 1500 80 mm 70 mm 25 mm M12 x 1.75
[3.15 in] [2.76 in] [0.98 in]
Characteristic Measure
2000, 3000, 108 mm 95 mm 25 mm M18 x 1.5
Strain gage type Foil
5000 [4.25 in] [3.75 in] [0.98 in]
Excitation (acceptable) 10 Vdc to 12 Vdc
7500, 10000 178 mm 130 mm 51 mm [2.0 M30 x 2
Excitation (max.) 15 Vdc [7.00 in] [5.12 in] in]
Insulation resistance > 5000 mOhm 15000, 20000 190 mm 160 mm 60 mm M30 x 2
Bridge resistance (toler- 400 ohm ±10 ohm (nominal) [7.48 in] [6.3 in] [2.36 in]
ance) - Input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - Output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) 6 m [19.69 ft] of 5 mm [0.2 in] diameter
cable

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 120 % full scale1
Later load limit 100 % full scale
Material Nickel plated alloy steel

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large Black Shield

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 123 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. IP68 rating for load ranges 7500 kg and greater.
4. This unit is calibrated to Metric (non-Imperial) units. or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008663-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 125
Load Cell
DESCRIPTION
The Model 125 load cells combines both a compact form and
high precision to offer a superior tension force transducer. The
one-piece S-shaped design achieves a maximum non-linearity of
0.03 % full scale for load ranges from 100 kg to 500 kg.

FEATURES
• 100 kg to 500 kg range
• ±0.02 % accuracy
• One-piece, nickel-plated alloy steel construction
• Mating connector and 5 m cable included
• Cost efficient

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 125

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 3
100, 200, 300, 500 kg LH 100 kg
Accuracy ±0.02 % full scale LK 200 kg
Output 2.0 mV/V LM 300 kg
Creep (max.) ±0.02 % full scale (30 minutes)
LN 500 kg

ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure MOUNTING DIMENSIONS
Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F]
Temperature, compensated -20 °C to 55 °C [-4 °F to 131 °F]
Temperature effect, zero ±0.02 % full scale/10 °C
Temperature effect, span ±0.02 % full scale/10 °C
Protection class IP67

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (acceptable) 10 Vdc to 12 Vdc
Excitation (max.) 15 Vdc
Insulation resistance > 5000 mOhm
Bridge resistance (toler- 400 ohm ±10 ohm (nominal)
ance) - Input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - Output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) Mating connector and 5 m [16.40 ft]
cable (included)

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Material Nickel plated alloy steel

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large Black Shield

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 125 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit is calibrated to Metric (non-Imperial) units.
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008665-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 127
Load Cell
DESCRIPTION
The Model 127 load cells combines both a compact form and
high precision to offer a superior tension force transducer. The
one-piece S-shaped design achieves a maximum non-linearity of
0.03 % full scale for load ranges of 50 kg and 100 kg.

FEATURES
• 50 kg, 100 kg range
• ±0.03 % FS accuracy
• Built-in overload resistance
• One-piece, nickel-plated alloy steel construction
• Integral cable
• Cost efficient

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 127

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 3
50 kg, 100 kg LF 50 kg
Accuracy ±0.03 % full scale LH 100 kg
Output 3.0 mV/V
Creep (max.) ±0.03 % full scale (30 minutes)
MOUNTING DIMENSIONS

ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F]
Temperature, compensated -20 °C to 55 °C [-4 °F to 131 °F]
Temperature effect, zero ±0.03 % full scale/10 °C
Temperature effect, span ±0.03 % full scale/10 °C
Protection class IP67

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (acceptable) 10 Vdc to 12 Vdc
Excitation (max.) 15 Vdc
Insulation resistance > 5000 mOhm
Bridge resistance (toler- 400 ohm ±10 ohm (nominal)
ance) - Input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - Output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) 5 m [16.40 ft] flying leads

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % full scale1
Material Nickel plated alloy steel

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large Black Shield

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 127 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit is calibrated to Metric (non-Imperial) units.
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008664-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 129
Load Cell
DESCRIPTION
The Model 129 load cells combines both a compact form and
high precision to offer a superior tension force transducer. The
one-piece S-shaped design achieves a maximum non-linearity of
0.02 % full scale for load ranges from 1000 kg to 5000 kg.

FEATURES
• 1000 kg to 5000 kg range
• ±0.02 % accuracy
• One-piece, nickel-plated alloy steel construction
• Integral cable
• Cost efficient

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 129

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 3
1000, 2000, 3000, 5000 kg LQ 1000 kg
Accuracy ±0.02 % full scale LS 2000 kg
Output 2.0 mV/V LY 3000 kg
Creep ±0.02 % full scale (30 minutes)
LU 5000 kg

ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure MOUNTING DIMENSIONS
Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F]
Temperature, compensated -20 °C to 55 °C [-4 °F to 131 °F]
Temperature effect, zero ±0.02 % full scale/10 °C
Temperature effect, span ±0.02 % full scale/10 °C
Protection class IP67

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (acceptable) 10 Vdc to 12 Vdc
Excitation (max.) 15 Vdc
Insulation resistance > 5000 mOhm
Bridge resistance (toler- 400 ohm ±10 ohm (nominal)
ance) - Input resistance
Bridge resistance (toler- 352 ohm ±2 ohm (nominal)
ance) - Output resistance
Zero balance (tolerance) ±1 % full scale
Electrical termination (std) 5 m [16.40 ft] flying leads

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Material Nickel plated alloy steel

WIRING CODES
Cable
Red (+) supply
Black (-) supply
Green (+) output
White (-) output
Large Black Shield

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 129 Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit is calibrated to Metric (non-Imperial) units.
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008666-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 53
Low Cost Load Cell
DESCRIPTION
Model 53 load cells are bonded foil strain gage transducers term stability and reliability under severe operating conditions.
designed for cost efficient production and testing applications The Model 53 compression-only load cell has an integral load
(i.e. press calibration). Engineered compression force button machined as part of the load cell. The Model 53 must be
measurements up to 50000 lb., this model achieves a maximum mounted on a smooth flat surface for proper operation. Three
non-linearity of 0.25 % full scale. Precision gaging techniques tapped holes are provided for mounting.
and a stainless steel construction provides excellent long-

FEATURES
• 5 lb to 50000 lb
• Stainless steel
• Mini footprint
• Button-style design
• mV/V output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 53
PERFORMANCE SPECIFICATIONS RANGE CODES
Characteristic Measure Range Available ranges Range Available ranges
Load ranges5 5 lb to 50000 lb Code Code
Linearity (max.) ±0.25 % full scale AT 5 lb DN 3000 lb

Hysteresis (max.) ±0.2 % full scale AV 10 lb DP 4000 lb

Non-repeatability (max.) ±0.1 % full scale BL 25 lb DR 5000 lb

Output (tolerance) 2 mV/V (nominal) BN 50 lb DT 7500 lb

Operation Compression BR 100 lb DV 10000 lb

Resolution Infinite CN 250 lb EJ 15000 lb


CR 500 lb EL 20000 lb
CV 1000 lb EN 30000 lb
ENVIRONMENTAL SPECIFICATIONS
DL 2000 lb EP 50000 lb
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
DEFLECTIONS AND RINGING FREQUENCIES
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature effect, zero 0.005 % full scale/°F Capacity Deflection @ Natural ring- Weight with
(lb) full scale (in) ing frequency cable g [lb]
Temperature effect, span 0.01 % full scale/°F (Hz)
5 0.001 2000 59 [0.13]
10 0.001 3000 59 [0.13]
ELECTRICAL SPECIFICATIONS
25 0.001 16000 62 [0.136]
Characteristic Measure
50 0.001 21000 63 [0.138]
Strain gage type Bonded foil
100 0.001 28000 64 [0.141]
Excitation (calibration) 5 Vdc
5 lb to 100 lb 250 0.001 25000 72 [0.158]

Excitation (calibration) 10 Vdc 500 0.001 32000 72 [0.158]


250 lb to 50000 lb 1000 0.001 42000 75 [0.165]
Insulation resistance 5000 mOhm @ 50 Vdc 2000 0.001 53000 77 [0.17]
Bridge resistance (toler- 350 ohm (nominal) 3000 0.001 27000 137 [0.30]
ance)
4000 0.001 31000 138 [0.304]
Zero balance (tolerance) ±3 % full scale
5000 0.001 34000 140 [0.306]
Shunt calibration data Included
7500 0.001 41000 142 [0.313]
Electrical termination (std) Teflon cable 1.83 m [5 ft]
10000 0.001 47000 145 [0.32]
15000 0.002 24000 368 [0.811]
MECHANICAL SPECIFICATIONS
20000 0.002 28000 372 [0.820]
Characteristic Measure
30000 0.002 33000 377 [0.831]
Weight See table
50000 0.003 24000 1270 [2.8]
Material 17-4 PH stainless steel
Maximum allowable load 150 % full scale1
Deflection full scale See table
Natural frequency See table

WIRING CODES
Cable Unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Low Cost Load Cell
MOUNTING DIMENSIONS
Ranges lb D1 mm [in] D2 mm [in] H mm [in] L mm [in] A in B mm [in] G mm [in]
5, 10, 25, 50, 100 25,4 [1.00] 5,33 [0.21] 15,75 [0.62] 1,27 [0.05] #4-40 UNC 5,59 [0.22] 19,05 [0.750]
250, 500, 1000, 2000 31,75 [1.25] 8,13 [0.32] 9,91 [0.39] 1,78 [0.07] #6-32 UNC 6,35 [0.25] 25,4 [1.000]

3000, 4000, 5000, 38,1 [1.50] 10,16 [0.40] 16,0 [0.63] 2,03 [0.08] #6-32 UNC 6,35 [0.25] 31,75 [1.250]
7500, 10000
15000, 20000, 30000 50,8 [2.00] 15,24 [0.60] 25,4 [1.00] 3,05 [0.12] #6-32 UNC 6,35 [0.25] 41,28 [1.625]
50000 76,2 [3.00] 19,81 [0.78] 38,1 [1.50] 4,57 [0.18] #6-32 UNC 6,35 [0.25] 60,33 [2.375]

OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000,
ranges 5000, 7500, 10000, 15000, 20000, 30000, 50000 lb
Tempera- 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F
ture com- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F
pensation 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output
amplifiers
Electrical 6d. Microtec DR-4S-4H 4-pin 6h. Integral cable:
termination 6e. Integral cable: Teflon Silicone
6f. Integral cable: PVC 6i. Integral underwa-
6g. Integral cable: Neoprene ter cable3
6v. Phoenix connector
on end of cable
Special 9a. 10 point (5 up/5 down) 20 % increments @ 68 °F
calibration 9b. 20 point (10 up/10 down) 10 % increments @ 68 °F
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module4

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 53 Low Cost Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. Dimension “H” may increase with option 6i. Consult factory. Maxi-
mum temperature is 180 °F. or replace, at its option, without charge those items it finds
4. TEDS available with integral cable units only. defective. The foregoing is buyer’s sole remedy and is in lieu
5. This unit calibrated to Imperial (non-Metric) units.
6. Signature calibration only available as inline module. of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
TYPICAL SYSTEM DIAGRAM event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this datasheet is for
reference only. DO NOT USE this document as product
Find out more installation information.
Honeywell serves its customers • Complete installation, operation and maintenance
through a worldwide network of information is provided in the instructions supplied with
each product.
sales offices, representatives
Failure to comply with these instructions could result in
and distributors. For application
death or serious injury.
assistance, current specifica-
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
008638-2-EN IL50 GLO 
Golden Valley, MN 55422 January 2010
Copyright © 2010 Honeywell International Inc. All rights reserved.
www.honeywell.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 41
Precision Low Profile Load Cell
DESCRIPTION
Model 41 is a low profile “pancake” type load cells. These reduce off-center and side-loading effects. It provides high
bonded foil, strain gage load cells are engineered to measure performance in non-linearity, hysteresis, and repeatability speci-
loads from 5 lb to 500,000 lb. The tension/ compression fications for such applications as tube mills, extruding processes
Model 41 is designed with the threaded hole running completely and weighing. Each unit has a welded construction and can be
through the center of the cell. Model 41 utilizes two stabilizing hermetically sealed for added durability. Model 41 load cells are
diaphragms, which are welded to the sensing member to available with optional 0 Vdc to 5 Vdc or 4 mA to 20 mA output.

Approved Approved Approved


Intrinsically safe amp

FEATURES
• 0.1 % accuracy
• 5 lb to 500000 lb
• mV/V output (standard); 4 mA to 20 mA and 0 Vdc to 5 Vdc
(optional) outputs
• Double diaphragm design
• Intrinsically safe available (2N option only)16
• CE approved17

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 41

PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS


Characteristic Measure Characteristic Measure
Load ranges 18
5 lb to 500000 lb Maximum allowable load 150 % FS 1
Non-linearity, 5 lb to 25 lb ±0.2 % full scale Weight See table
Hysteresis, Material 17-4PH stainless steel
±0.1 % full scale
50 lb to 500000 lb Less than 200,000 lb
Hysteresis, 5 lb to 25 lb ±0.1 % full scale Material greater than or Carbon steel
Hysteresis, equal to 300000 lb
±0.08 % full scale
50 lb to 500000 lb Deflection See table
Non-repeatability, 5 to 25 lb ±0.1 % full scale Natural frequency See table
Non-repeatability,
±0.03 % full scale
50 lb to 500000 lb
Output (tolerance), RANGE CODES
2 mV/V ±0.5 % full scale
5 lb to 25 lb Range Available ranges Range Available ranges
Output (tolerance), Code Code
3 mV/V ±0.5 % full scale
50 lb to 500000 lb AT 5 lb DV 10000 lb
Operation Compression/tension13 AV 10 lb EJ 15000 lb
Resolution Infinite BL 25 lb EL 20000 lb
5-point calibration: 0 %, 50 % and 100 BN 50 lb EN 30000 lb
Standard calibration
% of full scale in tension only
BR 100 lb EP 50000 lb
CN 250 lb ER 75000 lb
ENVIRONMENTAL SPECIFICATIONS CR 500 lb ET 100000 lb
Characteristic Measure CV 1000 lb FJ 150000 lb
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] DL 2000 lb FL 200000 lb
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] DN 3000 lb FN 300000 lb
Temperature effect, zero 0.002 % full scale/°F DP 4000 lb FP 400000 lb
Temperature effect, span 0.002 % full scale/°F DR 5000 lb FR 500000 lb
DT 7500 lb
ELECTRICAL SPECIFICATIONS
Characteristic Measure WIRING CODES
Strain gage type Bonded foil Connector Unamplified (Std.)
Excitation (calibration) 10 Vdc A (+) excitation
Insulation resistance 5000 mOhm @ 50 Vdc B (+) excitation
Bridge resistance 350 ohm (nominal) C (-) excitation
(tolerance) D (-) excitation
Zero balance (tolerance) ±1 % full scale E (-) output
Shunt calibration data Included F (+) output
Electrical termination (std) PTIH-10-6P
5 lb to 5000 lb
Electrical termination (std) MS3102E-14S-6P
DEFLECTIONS AND RINGING FREQUENCIES
7500 lb to 500000 lb Capacity (lb) Deflection @ Natural ringing Weight
Mating connector PT06A-10-6S or equiv. (AA111) full scale (in) frequency (Hz) (lb)
5 lb to 5000 lb (not incl.) 5 to 25 0.001 2000 0.8
Mating connector MS3106A-14S-6S (AA121) 50 to 1000 0.002 4600 1.5
7500 to 500000 lb (not incl.)
2000 to 5000 0.002 10000 2.0
7500 to 15000 0.003 6000 8.8
20000 to 50000 0.004 8000 11.0
75000 to 100000 0.006 5500 30.9
150000 to 200000 0.010 4500 46.3
2 Honeywell • Sensing and Control 300000 to 500000 0.010 4100 130.1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Low Profile Load Cell

iNTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2b put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal ±5 V 0-5 V or ±5 V @ 0-10 V or ±10 V 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
45 mA @ 45 mA
Input power (voltage) ±15 Vdc or 26-32 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. response 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db
Operating temperature -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse volt. protection Yes Yes Yes Yes Yes Yes
Short circuit protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt Cal 1 E Shunt Cal 1 E Shunt Cal 1 E Shunt Cal 1 E Case ground E Case ground
F Shunt Cal 2 F Shunt Cal 2 F Shunt Cal 2 F Shunt Cal 2 F No connection F No connection

Wiring code: cable R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output com* Bl Output com* Bl Output com* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt Cal 1 B Shunt Cal 1 B Shunt Cal 1 B Shunt Cal 1
Br Shunt Cal 2 Br Shunt Cal 2 Br Shunt Cal 2 Br Shunt Cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS


Capacity (lb) Side load Bending Torque
(lb) (lb-in) (lb-ft)
5 to 25 50 % 40 % 25 %
50 to 1000 45 % 35 % 25 %
2000 to 5000 30 % 25 % 25 %
7500 to 30000 20 % 20 % 15 %
50000 to 100000 20 % 20 % 15 %
150000 to 200000 20 % 20 % 15 %
300000 20 % 20 % 10 %
400000 20 % 20 % 10 %
500000 20 % 20 % 10 %

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 41
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 5000, 3000, 4000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000, 150000,
200000, 300000, 400000, 500000 lb
Temperature 1a. 60 °F to 160 °F 1d. -20 °F to 130 °F 1g. 70 °F to 325 °F14 1j. 0 °C to 50 °C
compensation 1b. 30 °F to 130 °F 1e. -20 °F to 200 °F 1h. 70 °F to 400 °F14 1k. -20 °C to 85 °C
1c. 0 °F to 185 °F 1f. 70 °F to 250 °F 1i. -65 °F to 250 °F14 1m. -25 °C to 110 °C
Internal 2b. 4 wire, ±5 Vdc 2j. 4-20 mA (three-wire) 2n (2N) 4 mA to 20 mA (wire) 2u. Unamplified, mV/V output
amplifiers 10 2c. 0-5 Vdc output output intrinsically safe20
2k. 4 mA to 20 mA (two- 2t. 0 Vdc to 10 Vdc
wire)20
Internal ampli- 3a. Input/output isolation19
fier enhance- 3d. Remote buffered shunt calibratrion8
ments
Overload 4a. Overload stops
stops
Electrical 6a. Bendix PTIH-10-6P 6-pin 6f. Integral cable: PVC 6i. Integral underwater 6q. Molded integral cable poly-
termination (ranges to 5000 lb) 6g. Integral cable: Neo- cable9 urethane9
6b. MS3102E-14S-6P (rang- prene9 6j. 1/2-14 conduit fitting with 6v. Phoenix connector on end of
es 7500 lb and up)9 6h. Integral cable: Silicone 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon cable
Shunt calibra- 8a. Precision internal resistor14
tion
Special cali- 9a. 10 point (5 up/5 down) 20 % increments @ 68 °F
bration 9b. 20 point (10 up/10 down) 10 % increments @ 68 °F
9c. ASTM E-74 calibration
Bridge resist- 12b. 5000 ohm (foil)
ance
Zero and span 14a. No access to pots
adjustment 14b. Top access to pots
Electrical con- 15a. Horizontal electrical exit port orientation 15c. Radial electrical exit port orientation
nector orienta- 15b. Vertical electrical exit port orientation 15d. Connector on end of cable
tion
Special cali- 30a. Compression only calibration, positive in compression
bration 30b. Tension and compression calibration, positive in tension
30c. Compression only calibration, negative in compression
30d. Tension and compression calibration, positive in compression
Bridge type 31a. Dual bridge
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration14
53t. TEDS IEEE 1451.4 module15

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Low Profile Load Cell

MOUNTING DIMENSIONS
Ranges D mm H mm H*** F# ØG ØK mm T A mm A* mm B mm B* mm C mm
lb [in] [in] mm mm [in] [in] [in] [in] [in] [in] [in]
[in] B.C. thru
5, 10, 25 63,5 20,32 44,45 6 50,8 4,83 1/4-28 20,83 63,5 19,05 22,86 31,75
[2.50] [0.80] [1.75] [2.000] [0.19] UNF [0.82] [2.5] [0.75] [0.9] [1.25]
50, 100, 76,2 25,4 44,45 6 57,15 7,11 3/8-24 20,83 63,5 19,05 22,86 31,75
250, 500, [3.00] [1.00] [1.75] [2.250] [0.28] UNF [0.82] [2.5] [0.75] [0.9] [1.25]
1000
2000, 88,9 25,4 44,45 6 66,68 8,64 1/2-20 20,83 63,5 19,05 22,86 31,75
3000, [3.50] [1.00] [1.75] [2.625] [0.34] UNF [0.82] [2.5] [0.75] [0.9] [1.25]
4000,
5000
7500, 139,7 45,7 45,7 8 114,3 10,16 1-14 31,75 58,42 38,1 38,1 50,8
10000, [5.50] [1.80] [1.80] [4.500] [0.40] UNS [1.25] [2.3] [1.50] [1.5] [2.00}
15000
20000, 152,4 45,7 45,7 8 123,83 13,46 1 1/2-12 31,75 58,42 38,1 38,1 50,8
30000, [6.00] [1.80] [1.80] [4.875] [0.53] UNF [1.25] [2.3] [1.50] [1.5] [2.00}
50000
75000, 228,6 63,5 63,5 12 196,85 16,76 2-12 UN 31,75 58,42 38,1 38,1 50,8
100000 [9.00] [2.50] [2.50] [7.750] [0.66] [1.25] [2.3] [1.50] [1.5] [2.00}
150000, 279,4 63,5 63,5 12 241,3 19,81 2 1/2-12 31,75 58,42 38,1 38,1 50,8
200000 [11.00] [2.50] [2.50] [9.500] [0.78] UN [1.25] [2.3] [1.50] [1.5] [2.00}
300000, 355,6 107,95 107,95 12 298,45 26,16 3 1/2-8 31,75 58,42 38,1 38,1 **
400000, [14.00] [4.25] [4.25] [11.750] [1.03] UN [1.25] [2.3] [1.50] [1.5]
500000
* Length of load cell with amplified option (see option codes)
** C dimension varies on high ranges. Consult factory
*** H dimension with 2n(2N) amplifier
TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 41 Precision Low Profile Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads - maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed with specific warranty details. If warranted goods are returned to
safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-
vides 50 % (unamplified units), 75 % (4 mA to 20 mA 3-wire units) or or replace, at its option, without charge those items it finds
80 % (voltage amplified units) of full scale output for quick calibration. defective. The foregoing is buyer’s sole remedy and is in lieu
Shunt calibration comes standard with internal amplifier option 2b, 2c,
2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector.
event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Adding any internal amplifiers on 5 lb to 25 lb ranges will increase
delivery time. While we provide application assistance personally, through our
7. Option 2n (2N) on 5 to 5000 lb. ranges will typically take 12 weeks for literature and the Honeywell web site, it is up to the customer to
delivery.
8. Option 3d is not available with option 2n (2N) or 2k. determine the suitability of the product in the application.
9. Not available with option 1c, 1e, 1f, 1g, 1h or 1i.
10.Consult factory. Specifications may change without notice. The information we
11.Availability varies with range, consult factory. supply is believed to be accurate and reliable as of this printing.
12.Option only pertinent when option 2n (2N) selected. However, we assume no responsibility for its use.
13.Standard calibration for tension/compression load cells is in tension
only. For more information about Sensing and Control products, visit
14.Not available with amplified output.
15.Consult factory for TEDS availability with amplified models. www.honeywell.com/sensing or call +1-815-235-6847
16.Range dependent; consult factory. Termination dependent; consult Email inquiries to info.sc@honeywell.com
factory.
17.Internal amp and termination dependent; consult factory.
18.This unit calibrated to Imperial (non-Metric) units. WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008609-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 43
Precision Low Profile Load Cell
DESCRIPTION
Model 43 is a low profile “pancake” type load cells. These bond- applications as tube mills, extruding processes and weighing.
ed foil, strain gage load cells are engineered to measure loads Each unit has a welded construction and can be hermetically
from 5 lb to 500,000 lb. The compression-only Model 43 has a sealed for added durability. Model 43 is available with optional 0
load button which is fixed as an integral part of the load cell and Vdc to 5 Vdc or 4 mA to 20 mA output.
cannot be removed or changed. It provides high performance in
non-linearity, hysteresis, and repeatability specifications for such
Approved Approved Approved
Intrinsically safe amp

FEATURES
• 0.10 % accuracy
• 5 lb to 500000 lb
• mV/V output (standard); 0 Vdc to 5 Vdc or 4 mA to 20 mA
(optional)
• Stainless steel
• Double diaphragm design

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 43

PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS


Characteristic Measure Characteristic Measure
Load ranges 9
5 lb to 500000 lb Maximum allowable load 150 % FS2
Non-linearity, 5 lb to 25 lb ±0.2 % full scale Weight See table
Hysteresis, Material 17-4PH stainless steel
±0.1 % full scale
50 lb to 500000 lb Less than 200,000 lb
Hysteresis, 5 lb to 25 lb ±0.1 % full scale Material greater than or Carbon steel
Hysteresis, equal to 300000 lb
±0.08 % full scale
50 lb to 500000 lb Deflection See table
Non-repeatability, 5 to 25 lb ±0.1 % full scale Natural frequency See table
Non-repeatability,
±0.03 % full scale
50 lb to 500000 lb RANGE CODES
Output (tolerance), Range Available ranges Range Available ranges
2 mV/V ±0.5 % full scale
5 lb to 25 lb Code Code
Output (tolerance), AT 5 lb DV 10000 lb
3 mV/V ±0.5 % full scale
50 lb to 500000 lb
AV 10 lb EJ 15000 lb
Operation Compression
BL 25 lb EL 20000 lb
Resolution Infinite
BN 50 lb EN 30000 lb
Standard calibration 5-point calibration, compression only
BR 100 lb EP 50000 lb
CN 250 lb ER 75000 lb
ENVIRONMENTAL SPECIFICATIONS
CR 500 lb ET 100000 lb
Characteristic Measure
CV 1000 lb FJ 150000 lb
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
DL 2000 lb FL 200000 lb
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
DN 3000 lb FN 300000 lb
Temperature effect, zero 0.002 % full scale/°F
DP 4000 lb FP 400000 lb
Temperature effect, span 0.002 % full scale/°F
DR 5000 lb FR 500000 lb
DT 7500 lb
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
DEFLECTIONS AND RINGING FREQUENCIES
Excitation (calibration) 10 Vdc Capacity (lb) Deflection @ Natural ringing Weight
full scale (in) frequency (Hz) kg (lb)
Excitation (acceptable) Up to 15 Vdc or Vac
5 to 25 0.001 2000 0.36 [0.8]
Insulation resistance 5000 mOhm @ 50 Vdc
50 to 1000 0.002 4500 0.68 [1.5]
Bridge resistance 350 ohm (nominal)
(tolerance) 2000 to 5000 0.002 11000 0.73 [1.6]

Zero balance (tolerance) ±1 % full scale 7500 to 30000 0.003 9000 2.90 [6.4]

Shunt calibration data Included 50000 to 100000 0.004 13000 2.99 [6.6]

Electrical termination (std) PTIH-10-6P 150000 to 200000 0.004 11000 5.31 [11.7]
5 lb to 5000 lb 300000 0.005 10000 10.8 [23.8]
Electrical termination (std) MS3102E-14S-6P 400000 0.007 8400 12.02
7500 lb to 500000 lb [26.5]
Mating connector PT06A-10-6S or equiv. (AA111) 500000 0.007 4800 41.00
5 lb to 5000 lb (not incl.) [90.4]
Mating connector MS3106A-14S-6S (AA121)
7500 to 500000 lb (not incl.)

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Low Profile Load Cell

INTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2a put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal 0 V to 5 V 0 V to 5 V or ±5 V 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA ±10 V @ 45 mA
Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
to 32 Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protec- Yes Yes Yes Yes Yes Yes
tion
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
(std)4 B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: cable4,5,6 R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS2 WIRING CODES


Capacity (lb) Side load Bending Torque Connector Unamplified (Std.)
(lb) (lb-in) (lb-ft) A (+) excitation
5 to 25 50 % 40 % 25 % B (+) excitation
50 to 1000 45 % 35 % 25 % C (-) excitation
2000 to 5000 30 % 25 % 25 % D (-) excitation
7500 to 30000 20 % 20 % 15 % E (-) output
50000 to 100000 20 % 20 % 15 % F (+) output
150000 to 200000 20 % 20 % 15 %
300000 20 % 20 % 10 %
400000 20 % 20 % 10 %
500000 20 % 20 % 10 %

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 43
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000,
150000, 200000, 300000, 400000, 500000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F11
compensation 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F11
1c. 0 °F to 185 °F 1i. -65 °F to 250 °F
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2a. Four wire, 0 Vdc to 5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe10
amplifiers 2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
2j. 4 mA to 20 mA (three-wire) output 2u. Unamplified, mV/V output
2k. 4 mA to 20 mA (two-wire)10
Internal amplifier 3a. Input/output isolation7
enhancements 3d. Remote buffered shunt calibration8
Electrical 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 °F) 6f. Integral cable: PVC
termination 6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6g. Integral cable: Neoprene
14S-6S) (max. 160 °F) (ranges above 5000 lb)12 6h. Integral cable: Silicone
6e. Integral cable: Teflon 6i. Integral underwater cable
6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
Shunt 8a. Precision internal resistor11
calibration
Special 9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
calibration 9b. 20 point (10 up/10 down) 10 % increments @ 70 °F
9c. ASTM E-74 calibration
Bridge 12. 5000 ohm (foil) (max. 250 °F)
resistance
Bridge type 31a. Dual bridge
Zero and span 14a. No access to pots
adjustment 14b. Top access to pots
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Special 30a. Compression only, positive output
calibration
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration11
53t. TEDS IEEE 1451.4 module8

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Low Profile Load Cell

MOUNTING DIMENSIONS

Ranges lb D1 mm [in] D2 mm [in] H mm F typ. ØG mm A mm A* mm B mm B* mm C mm


[in] dia. [in] B.C. [in] [in] [in] [in] [in]
5, 10, 25 63,5 [2.50] 9,4 [0.37] 24,89 #8 50,8 20,83 63,5 [2.5] 19,05 22,86 [0.9] 31,75
[0.98] [2.000] [0.82] [0.75] [1.25]
50, 100, 250, 76,2 [3.00]1 14,22 [0.56] 29,97 1/4 57,15 20,83 63,5 [2.5] 19,05 22,86 [0.9] 31,75
500, 1000 [1.18] [2.250] [0.82] [0.75] [1.25]
2000, 3000, 88,9 [3.50] 17,53 [0.69] 29,97 5/16 66,68 20,83 63,5 [2.5] 19,05 22,86 [0.9] 31,75
4000, 5000 [1.18] [2.625] [0.82] [0.75] [1.25]
7500, 10000, 114,3 [4.50] 38,1 [1.50] 50,8 [2.00] 3/8 96,27 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
15000, 20000, [3.790] [1.25]
30000
50000, 75000, 114,3 [4.50] 38,1 [1.50] 50,8 [2.00] 3/8 96,27 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
100000 [3.790] [1.25]
150000, 139,7 [5.50] 50,8 [2.00] 55,37 3/8 122,22 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
200000 [2.18] [4.812] [1.25]
300000 177,8 [7.00] 63,5 [2.50] 68,1 [2.68] 3/8 152,4 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
[6.00] [1.25]
400000 190,5 [7.50] 63,5 [2.50] 68,1 [2.68] 3/8 171,45 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
[6.750] [1.25]
500000 279,4 [11.0] 120,65 [4.75] 114,3 3/4 241,3 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
[4.50] [9.500] [1.25]
* Length of load cell with amplified option (see option codes)

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 43 Precision Low Profile Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. 0.12 mm [3.00 in] diameter has six mounting holes.
2. Allowable maximum loads - maximum load to be applied without Honeywell’s standard product warranty applies unless agreed
damage.3 to otherwise by Honeywell in writing; please refer to your
3. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue order acknowledgement or consult your local sales office for
life for long term use and structural integrity. All structurally critical specific warranty details. If warranted goods are returned to
applications (overhead loading, etc.) should always be designed
with safety redundant load paths. Honeywell during the period of coverage, Honeywell will repair
4. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal or replace, at its option, without charge those items it finds
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire
defective. The foregoing is buyer’s sole remedy and is in lieu
units) or 80 % (voltage amplified units) of full scale output for quick
calibration. Shunt calibration comes standard of all warranties, expressed or implied, including those of
with internal amplifier option 2a, 2b, 2c, 2t and 2j. merchantability and fitness for a particular purpose. In no
5. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
W=White; G=Green. Color specifying cable and number or letter event shall Honeywell be liable for consequential, special, or
specifying connector indirect damages.
6. No mating connector necessary for cable option.
7. Only available with option 2a or 2c. While we provide application assistance personally, through our
8. Consult factory for TEDS availability with amplified models.
9. This unit calibrated to Imperial (non-Metric) units. literature and the Honeywell web site, it is up to the customer to
10. 5000 ohm bridge required. determine the suitability of the product in the application.
11. Cannot be used with amplified option.
12. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008627-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 75
Precision Low Profile Load Cell
DESCRIPTION
Model 75 fatigue rated load cells are engineered for applications Model 75 measures tension/compression and must be used on a
such as materials or product fatigue testing, which involve an smooth flat surface to achieve rated specifications. The tension/
extremely large number of cycles or occasional overload condi- compression Model 75 is designed with the threaded hole run-
tions. These fatigue rated load cells have load ranges from 50 lb ning completely through the center of the cell. Model 75 utilizes
to 200,000 lbs and achieve a non-linearity of 0.1% full scale. The two stabilizing diaphragms, which are welded to the sensing
superior design of these bonded foil, strain gage compression member to reduce off-center and side-loading effects.
and/or tension load cells permits a fatigue life of 1 billion cycles
(zero to full scale).

Approved Approved Approved


Intrinsically safe amp

FEATURES
• 0.10 % accuracy
• 50 lb to 200000 lb
• mV/V output (standard); 4 mA to 20 mA or 0 Vdc to 5 Vdc
(optional) outputs
• Stainless steel
• Double diaphragm design
• Enhanced overload capacity
• Intrinsically safe available (2N option only)8
• CE approved9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 75

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Available ranges Range Available ranges
Load ranges 10
50 lb to 200000 lb Code Code
Non-linearity ±0.1 % full scale BN 50 lb DV 10000 lb

Hysteresis ±0.1 % full scale BR 100 lb EJ 15000 lb

Non-repeatability ±0.03 % full scale CN 250 lb EL 20000 lb

Output (tolerance) 2 mV/V ±0.5 % full scale CR 500 lb EN 30000 lb

Operation Compression/tension CV 1000 lb EP 50000 lb


DL 2000 lb ER 75000 lb
Resolution Infinite
DN 3000 lb ET 100000 lb
5-point calibration, 0 %, 50 %, and 100 DP 4000 lb FJ 150000 lb
Standard calibration
% of full scale in tension only
DR 5000 lb FL 200000 lb
DT 7500 lb
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure WIRING CODES
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Connector Unamplified (Std.)
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
A (+) excitation
Temperature effect, zero 0.002 % full scale/°F
B (+) excitation
Temperature effect, span 0.002 % full scale/°F
C (-) excitation
D (-) excitation
ELECTRICAL SPECIFICATIONS E (-) output
Characteristic Measure F (+) output
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Insulation resistance 5000 mOhm @ 50 Vdc
DEFLECTIONS AND RINGING FREQUENCIES
Bridge resistance 350 ohm Capacity (lb) Deflection @ Natural ring- Weight g [lb]
(tolerance) full scale (in) ing frequen-
cy (kHz)
Zero balance (tolerance) ±1 % full scale
50 to 500 0.001 2.5 730 [1.61]
Shunt calibration data Included
1000 to 2000 0.002 10 900 [1.98]
Electrical termination (std) PTIH-10-6P
50 lb to 2000 lb 3000 to 7500 0.002 8 4000 [8.82]
Electrical termination (std) MS3102E-14S-6P 10000 to 20000 0.003 10 5000 [11.02]
3000 lb to 200000 lb 30000 to 50000 0.003 8.2 8600 [18.96]
Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)
75000 to 100000 0.004 7.5 15000 [33.07]
50 lb to 2000 lb
150000 to 0.006 4.5 21000 [46.3]
Mating connector (not incl.) MS3106A-14S-6S (AA121)
200000
3000 to 200000 lb

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 200 % FS 2
Weight See table
Material < 100000 lb 17-4PH stainless steel
Material > 125000 lb Carbon steel
Life cycles (approx.) > 108 cycles fully reversed
Deflection See table
Natural frequency See table

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Low Profile Load Cell

INTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2b put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA ±10 V @ 45 mA
Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
to 32 Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protec- Yes Yes Yes Yes Yes Yes
tion
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
(std)4 B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: cable4,5,6 R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS2


Capacity (lb) Side load Bending Torque (lb-ft)
(lb) (lb-in)
50 to 500 75 % 60 % 35 %
1000 to 2000 45 % 35 % 35 %
3000 to 7500 30 % 30 % 25 %
10000 to 20000 30 % 30 % 25 %
30000 to 50000 30 % 30 % 15 %
75000 to 100000 30 % 30 % 15 %
150000 to 30 % 30 % 15 %
200000

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 75
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 150000, 200000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F13
compensation 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F13
1c. 0 °F to 185 °F 1i. -65 °F to 250 °F13
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2b. Four wire, ±5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12
amplifiers 2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
2j. 4 mA to 20 mA (three-wire) output 2u. Unamplified, mV/V output
2k. 4 mA to 20 mA (two-wire)12
Internal amplifier 3a. Input/output isolation11
enhancements 3d. Remote buffered shunt calibration8
Electrical 6a. Bendix PTIH-10-6P (ranges to 2000 lb) 6g. Integral cable: Neoprene
termination 6b. MS connector MS3102E-14S-6P (mates 6h. Integral cable: Silicone
with MS3106E-14S-6S) (max. 160 °F) 6i. Integral underwater cable
(ranges 2000 lb and above)14 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon
6f. Integral cable: PVC
Shunt calibration 8a. Precision internal resistor13
Bridge resistance 12b. 5000 ohm (foil) (max. 250 °F)
Bridge type 31a. Dual bridge
Zero and span 14a. No access to pots
adjustment 14b. Top access to pots
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Special 30a. Compression only calibration, positive in compression
calibration 30b. Tension and compression calibration, positive in tension
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration13
53t. TEDS IEEE 1451.4 module7

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Low Profile Load Cell

MOUNTING DIMENSIONS
Ranges D mm H mm F# ØG mm ØK mm T A mm A* mm B mm B* mm C mm
lb [in] [in] [in] B.C. [in] thru [in] [in] [in] [in] [in]
50 to 76,2 25,4 6 57,15 7,11 3/8-24 20,83 63,5 [2.5] 19,05 22,86 31,75
500 [3.00] [1.00] [2.250] [0.28] UNF [0.82] [0.75] [0.9] [1.25]
1000 to 88,9 25,4 6 66,68 8.64 1/2-20 20,83 63,5 [2.5] 19,05 22,86 31,75
2000 [3.50] [1.00] [2.625] [0.34] UNF [0.82] [0.75] [0.9] [1.25]
3000 to 139,7 45,72 8 114,3 10,16 1-14 UNS 31,75 58,42 38,1 38,1 [1.5] 50,8
7500 [5.50] [1.80] [4.500] [0.40] [1.25] [2.3] [1.50] [2.00]
10000 to 152,4 45,72 8 123,83 13,46 1 1/2-12 31,75 58,42 38,1 38,1 [1.5] 50,8
20000 [6.00] [1.80] [4.875] [0.53] UN [1.25] [2.3] [1.50] [2.00]
30000 to 190,5 50,8 8 152,4 19,81 2-12 UN 31,75 58,42 38,1 38,1 [1.5] 50,8
50000 [7.50] [2.00] [6.00] [0.78] [1.25] [2.3] [1.50] [2.00]
75000 to 228,6 63,5 12 196,85 16,76 2 1/2-12 31,75 58,42 38,1 38,1 [1.5] 50,8
100000 [9.0] [2.50] [7.75] [0.66] UN [1.25] [2.3] [1.50] [2.00]
150000, 355,6 107,95 12 298,45 26,16 3 1/2-8 31,75 58,42 38,1 38,1 **
200000 [14.00] [4.25] [11.750] [1.03] UN [1.25] [2.3] [1.50] [1.50]

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 75 Precision Low Profile Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. C dimension varies on high ranges. Consult factory.
2. Allowable maximum loads - maximum load to be applied without Honeywell’s standard product warranty applies unless agreed
damage.3 to otherwise by Honeywell in writing; please refer to your
3. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue life order acknowledgement or consult your local sales office for
for long term use and structural integrity. All structurally critical ap- specific warranty details. If warranted goods are returned to
plications (overhead loading, etc.) should always be designed with
safety redundant load paths. Honeywell during the period of coverage, Honeywell will repair
4. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal or replace, at its option, without charge those items it finds
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire
defective. The foregoing is buyer’s sole remedy and is in lieu
units) or 80 % (voltage amplified units) of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier of all warranties, expressed or implied, including those of
option 2a, 2b, 2c, 2t and 2j. merchantability and fitness for a particular purpose. In no
5. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
W=White; G=Green. Color specifying cable and number or letter event shall Honeywell be liable for consequential, special, or
specifying connector. indirect damages.
6. No mating connector necessary for cable option.
7. Consult factory for TEDS availability with amplified models. While we provide application assistance personally, through our
8. Range dependent; consult factory. Termination dependent; consult
factory. literature and the Honeywell web site, it is up to the customer to
9. Internal amp and termination dependent; consult factory. determine the suitability of the product in the application.
10. This unit calibrated to Imperial (non-Metric) units.
11. Input/output isolation only available with voltage output (2b or 2c) Specifications may change without notice. The information we
amplifiers.
12. 5000 ohm bridge required. supply is believed to be accurate and reliable as of this printing.
13. Cannot be used with amplified option. However, we assume no responsibility for its use.
14. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008611-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model UG
Ultra Precision Universal Canister Load Cell
DESCRIPTION
Model UG Ultra Precision Universal load cell achieves scale on both ends facilitate mounting in any position for tension,
quality and performance standards.The Model UG achieves compression, or universal force measurements. Model UG load
±0.03 % non-linearity with very little deflection (typically .0045 cells can be used in both static and dynamic applications.
in). It utilizes a four arm strain gage bridge which is bonded Stainless steel construction ensures high reliability.
and tested for high precision and dependability. Female threads

FEATURES
• 5 lb to 50000 lb
• 0.03 % non-linearity and hysteresis, respectively
• Stainless steel
• Mini footprint
• Button-style design
• mV/V output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model UG

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Available ranges Range Available ranges
Load ranges 12
100 lb to 150000 lb Code Code
Non-linearity ±0.03 % full scale1 BR 100 lb DV 10000 lb

Hysteresis ±0.03 % full scale1 CN 250 lb EJ 15000 lb

Non-repeatability ±0.02 % full scale CR 500 lb EL 20000 lb

Output (tolerance) 3 mV/V ±1 % CV 1000 lb EN 30000 lb

Load direction Tension/compression4 DL 2000 lb EP 50000 lb

Resolution Infinite DN 3000 lb ER 75000 lb

Creep (max.) 0.02 % (20 min.) DP 4000 lb ET 100000 lb


DR 5000 lb FJ 150000 lb

ENVIRONMENTAL SPECIFICATIONS DT 7500 lb

Characteristic Measure
MOUNTING DIMENSIONS
Temperature, operating -34 °C to 85 °C [-30 °F to 185 °F]5
Rang- H mm ØD1 ØD2 ØD3 A mm T
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]5
es lb [in] mm mm mm [in]
Temperature, storage -73 °C to 121 °C [-100 °F to 250 °F] [in] [in] [in]
Temperature effect, zero 0.0015 % full scale/°F 100 69,85 50,8 16,00 48,26 2,29 3/8-24 UNF
Temperature effect, span 0.0008 % full scale/°F [2.75] [2.00] [0.63] [1.9] [0.09] x 7/16 in
250, 69,85 50,8 16,00 48,26 4,57 3/8-24 UNF
500 [2.75] [2.00] [0.63] [1.9] [0.18] x 7/16 in
ELECTRICAL SPECIFICATIONS
1000, 104,90 63,5 19,05 50,8 4,57 1/2-20 UNF
Characteristic Measure 2000, [4.13] [2.50] [0.75] [2.00] [0.18] x 5/8 in
Strain gage type Bonded foil 3000,
4000
Excitation (calibration) 10 Vdc
5000, 149,35 88,9 39,62 76,2 4,83 1-14 UNF x
Insulation resistance 5000 mOhm @ 50 Vdc 7500, [5.88] [3.50] [1.56] [3.00] [0.19] 1 1/8 in
Bridge resistance 350 ohm 10000
Zero balance 1 % of full scale 15000, 215,9 127 60,45 109,22 16,00 1 1/2-12
Electrical termination (std) MS3102E-14S-6P 20000, [8.50] [5.00] [2.38] [4.3] [0.63] UNF x 2 in
30000
Mating connector (not MS3106A-14S-6S (AA121)
included) 50000, 304,8 152,4 92,20 139,7 17,53 2-12 UNF x
75000 [12.00] [6.00] [3.63] [5.5] [0.69] 2 1/2 in
100000, 401,32 190,5 121,92 172,72 17,53 3-8 UNF x 4
MECHANICAL SPECIFICATIONS 150000 [15.80] [7.5] [4.8] [6.8] [0.69] 1/2 in
Characteristic Measure
Maximum allowable load 150 % FS 2
Material Stainless steel

WIRING CODES
Connector Unamplified
A (+) excitation
B (+) excitation
C (-) excitation
D (-) excitation
E (-) output
F (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Ultra Precision Universal Canister Load Cell

INTERNAL AMPLIFIERS
Intrinsically
Amplifier Voltage output: Voltage output: Voltage output: Current three- Current two-
safe amp: Op-
specifications Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tion 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
(voltage) 32 Vdc 40 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage Yes Yes Yes Yes Yes Yes
protection
Short cir. pro- Momentary Momentary Momentary Yes Yes Yes
tection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector (std) B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable5,6,7 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model UG
OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500,
ranges 10000, 15000, 20000, 30000, 50000, 75000, 100000,
150000 lb
Tempera- 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F14
ture com- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F14
pensation 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F14
1d. -20 °F to 200 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2b. ±5 Vdc 2n (2N) 4 mA to 20 mA
amplifiers 2c. 0 Vdc to 5 Vdc (wire) intrinsically safe13
output 2t. 0 Vdc to 10 Vdc
2j. 4 mA to 20 mA (three- 2u. Unamplified, mV/V
wire) out output
2k. 4 mA to 20 mA (two-
wire)13
Electrical 6a. Bendix PTIH-10-6P 6g. Integral cable: Neo-
termination (or equivalent) 6-pin prene
(max. 250 °F) 6i. Submersible cable15
6b. MS connector 6j. 1/2-14 conduit fitting
MS3102E-14S- with 5 ft of 4 conductor
6P (mates with PVC cable
MS3106E-14S-6S) 6q. Integral cable: Poly-
(max 160 °F)16 urethane
6e. Integral cable: Teflon
Shunt cali- 8a. Precision internal resistor14
bration
Bridge 12b. 5000 ohm (foil)
resistance 11a. Square bridge14
11b. Symmetrical bridge14
11c. Square and symmetrical bridge14
Special 30a. Compression only calibration, positive in com-
calibration pression
30b. Tension and compression calibration, positive in
tension
30c. Compression only calibration, negative in com-
pression
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration14
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model UG Ultra Precision Universal Canister Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. ±0.05% full scale less than or equal to 250 lb and greater than or
equal to 75000 lb. Honeywell’s standard product warranty applies unless agreed
2. Allowable maximum loads - maximum load to be applied without to otherwise by Honeywell in writing; please refer to your
damage.3
3. Without damage – loading to this level will not cause excessive order acknowledgement or consult your local sales office for
zero shift or performance degradation. The user must consider specific warranty details. If warranted goods are returned to
fatigue life for long term use and structural integrity. All structur-
Honeywell during the period of coverage, Honeywell will repair
ally critical applications (overhead loading, etc.) should always be
designed with safety redundant load paths. or replace, at its option, without charge those items it finds
4. Standard calibration for tension/ compression load cells is in ten- defective. The foregoing is buyer’s sole remedy and is in lieu
sion only.
5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal of all warranties, expressed or implied, including those of
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire merchantability and fitness for a particular purpose. In no
units) or 80 % (voltage amplified units) of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier event shall Honeywell be liable for consequential, special, or
option 2b, 2c, 2t and 2j. indirect damages.
6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
W=White; G=Green. Color specifying cable and number or letter While we provide application assistance personally, through our
specifying connector.
7. No mating connector necessary for cable option. literature and the Honeywell web site, it is up to the customer to
8. Consult factory for extended temperature ranges. determine the suitability of the product in the application.
9. Consult factory for TEDS availability with amplified models.
10. Range dependent; consult factory. Termination dependent; consult Specifications may change without notice. The information we
factory.
11. Internal amp and termination dependent; consult factory. supply is believed to be accurate and reliable as of this printing.
12. This unit calibrated to Imperial (non-Metric) units. However, we assume no responsibility for its use.
13. 5000 ohm bridge required
14. Not available with amplified options. For more information about Sensing and Control products, visit
15. Temperature 82 °C [180 °F] max., non-shielded standard, shielded
available. www.honeywell.com/sensing or call +1-815-235-6847
16. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008643-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model AL-JP
High Output Load Cell
DESCRIPTION
Model AL-JP is a high output load cell (30 mV/V minimum). performance in non-linearity, hysteresis, and repeatability. Low
These semiconductor strain gage load cells are engineered to mechanical deflection allows for better response capability.
measure loads from 500 lb to 2000 lb. The tension/compression
Model AL-JP is designed with female threads. It provides high

FEATURES
• 500 lb, 1000 lb, and 2000 lb range
• Tension/compression
• High output/low bridge resistance (125 Ohm nominal)
• Drive meters without amplification
• Low mechanical deflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model AL-JP
PERFORMANCE SPECIFICATIONS WIRING CODES
Characteristic Measure Tension
Load ranges4 500, 1000, 2000 lb A (+) excitation
Accuracy (static error B (+) signal
±0.15 % full scale
band)1 C (-) signal
Non-repeatability ±0.05 % full scale D (-) excitation
Output 30 mV/V minimum E shield
Operation Tension/compression
Resolution Infinite Compression
A (+) excitation
ENVIRONMENTAL SPECIFICATIONS B (-) signal

Characteristic Measure C (+) signal

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] D (-) excitation

Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F] E shield

Temperature, storage -73 °C to 121 °C [-100 °F to 250 °F]


Temperature effect, zero 0.5 % full scale/°F RANGE CODES
Temperature effect, span 0.5 % reading/°F Range Codes Range
CR 500 lb
ELECTRICAL SPECIFICATIONS CV 1000 lb
Characteristic Measure DL 2000 lb
Strain gage type Bonded semiconductor
Excitation (calibration) 5 Vdc or Vac (RMS)
OPTION CODES
Insulation resistance 5000 mOhm @ 50 Vdc or V
Many range/option combinations are available
Bridge resistance 125 ohm nominal (input and output) in our quick-ship and fast-track manufacture
Zero balance 3.0 % full scale (max.) programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Electrical termination (std) 3106B-14S-5P connector mounted at
end of 10 ft cable Load range 500 lb, 1000 lb, 2000 lb
Temperature 10 °F to 120 °F
compensation
MECHANICAL SPECIFICATIONS
Internal 2u. Unamplified, mV/V output
Characteristic Measure amplifiers
Maximum allowable load 150 % full scale 2 Electrical 3106B-14S-5P connector mounted at end of 10 ft
Side load without damage 100 % termination cable
Weight See table Special 30a. Compression only (+) output
calibration 30b. Tension and compression (+,-) output
Material 17-4 PH stainless steel
30c. Compression only (-) output
Deflection See table
Natural frequency See table

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Output Load Cell
MOUNTING DIMENSIONS DEFLECTIONS AND RINGING FREQUENCIES
Capacity Axial deflec- Natural fre- Weight kg [lb]
tion at full quency (Hz)
scale mm [in]
500 lb 0,025 mm 5000 0,544 [1.2]
[0.0010]
1000 lb 0,038 mm 6000 0,544 [1.2]
[0.0015]
2000 lb 0,051 mm 6700 0,544 [1.2]
[0.0020]

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model AL-JP High Output Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Static error band is the recommended performance specifica-
Honeywell’s standard product warranty applies unless agreed
tion. The static error band is calculated as the best fit straight line
through zero, including the effects of non-linearity, hysteresis and to otherwise by Honeywell in writing; please refer to your
non-repeatability. order acknowledgement or consult your local sales office for
2. Allowable maximum loads – maximum load to be applied without
specific warranty details. If warranted goods are returned to
damage3.
3. Without damage - loading to this level will not cause excessive zero Honeywell during the period of coverage, Honeywell will repair
shift of performance degradation. The user must consider fatigue or replace, at its option, without charge those items it finds
life for long term use and structural integrity. All structurally critical defective. The foregoing is buyer’s sole remedy and is in lieu
applications (overhead loading, etc.) should always be designed
with safety redundant load paths. of all warranties, expressed or implied, including those of
4. This unit calibrated to Imperial (non-Metric) units. merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more WARNING


Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this catalogue is for
sales offices, representatives and reference only. DO NOT USE this document as product
distributors. For application as- installation information.
• Complete installation, operation and maintenance
sistance, current specifications,
information is provided in the instructions supplied with
pricing or name of the nearest each product.
Authorized Distributor, contact
Failure to comply with these instructions could result in
your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008673-2-EN IL50 GLO 
March 2009
www.honeywell.com Copyright © 2009 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model AL-SC
High Output Load Cell
DESCRIPTION
Model AL-SC is high-output load cell. These semiconductor linearity, hysteresis, and repeatability. Low mechanical deflection
strain gage load cells are engineered to measure loads from 500 allows for better response capability.
lb to 2000 lb. The tension/compression Model AL-SC is de-
signed with female threads. It provides high performance in non-

FEATURES
• 500 lb, 1000 lb, and 2000 lb range
• 0.15 % accuracy
• Tension/compression
• High output/low bridge resistance
• Low mechanical deflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model AL-SC

PERFORMANCE SPECIFICATIONS WIRING CODES


Characteristic Measure Tension
Load ranges 4
500, 1000, 2000 lb A (+) excitation
Accuracy (static error B (+) signal
±1.25 % full scale
band)1 C (-) signal
Non-repeatability ±0.10 % full scale D (-) excitation
Output 70 mV/V minimum E shield
Operation Tension/compression
Resolution Infinite Compression
A (+) excitation
ENVIRONMENTAL SPECIFICATIONS B (-) signal

Characteristic Measure C (+) signal

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] D (-) excitation

Temperature, compensated -12 °C to 49 °C [10 °F to 120 °F] E shield

Temperature, storage -73 °C to 121 °C [-100 °F to 250 °F]


Temperature effect, zero 0.5 % full scale/°F RANGE CODES
Temperature effect, span 1.0 % reading/°F Range Codes Range
CR 500 lb
ELECTRICAL SPECIFICATIONS CV 1000 lb
Characteristic Measure DL 2000 lb
Strain gage type Bonded semiconductor
Excitation (calibration) 24 Vdc or Vac (RMS)
OPTION CODES
Insulation resistance 5000 mOhm @ 50 Vdc
Many range/option combinations are available
Bridge resistance, input 1000 ohm (nominal)
in our quick-ship and fast-track manufacture
Bridge resistance, output 3000 ohm (nominal) programs. Please see http://sensing.honeywell.
Zero balance 1.5 % full scale (max.) com/TMsensor-ship for updated listings.

Electrical termination (std) MS3100A-14S-5P at end of 1 ft cable Load range 500 lb, 1000 lb, 2000 lb
Temperature 10 °F to 120 °F
compensation
MECHANICAL SPECIFICATIONS Internal 2u. Unamplified, mV/V output
Characteristic Measure amplifiers
Maximum allowable load 200 % full scale 2 Electrical 3106B-14S-5P connector mounted at end of 10 ft
termination cable
Side load without damage 25 % full scale
Special 30a. Compression only (+) output
Weight See table
calibration 30b. Tension and compression (+,-) output
Material 17-4 PH stainless steel 30c. Compression only (-) output
Deflection See table
Natural frequency See table

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Output Load Cell

MOUNTING DIMENSIONS DEFLECTIONS AND RINGING FREQUENCIES


Capacity Axial deflec- Natural fre- Weight kg [lb]
tion at full quency (Hz)
scale mm [in]
500 lb 0,025 mm 5000 0,544 [1.2]
[0.0010]
1000 lb 0,038 mm 6000 0,544 [1.2]
[0.0015]
2000 lb 0,051 mm 6700 0,544 [1.2]
[0.0020]

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model AL-SC High Output Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Static error band is the recommended performance specifica-
tion. The static error band is calculated as the best fit straight line Honeywell’s standard product warranty applies unless agreed
through zero, including the effects of linearity, hysteresis and non- to otherwise by Honeywell in writing; please refer to your
repeatability.
2. Allowable maximum loads – maximum load to be applied without order acknowledgement or consult your local sales office for
damage3. specific warranty details. If warranted goods are returned to
3. Without damage - loading to this level will not cause excessive zero
Honeywell during the period of coverage, Honeywell will repair
shift of performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical or replace, at its option, without charge those items it finds
applications (overhead loading, etc.) should always be designed defective. The foregoing is buyer’s sole remedy and is in lieu
with safety redundant load paths.
4. This unit calibrated to Imperial (non-Metric) units. of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008672-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 Low
Low Range Precision Miniature Load Cell
DESCRIPTION
Model 31 low range precision miniature load cells measure term stability for ranges 1000 grams and above.) A modification
both tension and compression load forces of 50 grams to 500 permits this model to be completely welded for underwater
g. These models are our highest accuracy, rugged miniature applications. The Model 31 tension/compression load cell has
load cells. Model 31’s welded, stainless steel construction is male threads attachments. High accuracies of 0.15 % to 0.25 %
designed to eliminate or reduce to a minimum, the effects of full scale are achieved. Each bonded strain gage unit is built of
off-axis loads. (The internal construction assures excellent long- welded 17-4 PH stainless steel for additional ruggedness.

FEATURES
• 50 g to 500 g
• mV/V output
• Stainless steel
• Miniature design
• Double diaphragm construction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 Low

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Codes Range
Load ranges 5
50 g, 150 g, 250 g, 500 g AJ 50 g
Linearity ±0.15 % full scale AL 150 g
Hysteresis ±0.15 % full scale AN 250 g
Non-repeatability ±0.1 % full scale AP 500 g
Tolerance on output
0,1 mV/V max.
50 g to 150 g
OPTION CODES
Tolerance on output
20 mV/V Many range/option combinations are available in
250 g to 500 g
our quick-ship and fast-track manufacture pro-
Operation Tension/compression 3
grams. Please see http://sensing.honeywell.com/
Resolution Infinite TMsensor-ship for updated listings.
Load range 50, 150, 250, 500 g

ENVIRONMENTAL SPECIFICATIONS Temperature 1a. 60 °F to 160 °F 1e. -20 °F to 200 °F


compensa- 1b. 30 °F to 130 °F 1j. 0 °F to 50 °C
Characteristic Measure tion 1c. 0 °F to 185 °F 1k. -20 °C to 85 °C
Temperature, operating -53 °C to 121 °C [-65 °F to 250 °F] 1d. -20 °F to 130 °F 1m. -25 °C to 110 °C
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] Internal am- 2u. Unamplified, mV/V output
plifiers
Storage temperature -73 °C to 148 °C [-100 °F to 300 °F]
Overload 4a. Overload stop
Temperature effect, zero 0.015 % full scale/°F
stops
Temperature effect, span 0.015 % full scale/°F
Electrical 6d. Microtec DR-4S-4H 6i. Integral underwater
termination 4-pin cable (max. 82 °C
6e. Integral cable: Teflon [180 °F])
ELECTRICAL SPECIFICATIONS 6f. Integral cable: PVC 6v. Phoenix connector
Characteristic Measure 6h. Integral cable: Sili- on end of cable
Strain gage type Semiconductor cone 15d. Connector on end
of cable
Excitation (calibration) 5 Vdc
Special cali- 30a. Compression only calibration, positive in com-
Insulation resistance 5000 Mohm @ 50 Vdc bration pression
Bridge resistance 500 ohm 30b. Tension and compression calibration, positive
in tension
Zero balance 1 % max.
30c. Compression only calibration, negative in com-
Electrical termination (std) Teflon cable (5 ft) pression
Shock and 44a. Shock and vibration resistance
vibration
MECHANICAL SPECIFICATIONS
Interfaces 4 53e. Signature calibration6
Characteristic Measure 53t. TEDS IEEE 1451.4 module
Maximum allowable load 5 lb1
Weight 90 g
MOUNTING DIMENSIONS
Material 17-4 PH stainless steel
Deflection full scale 0,020 mm [0.0008 in]
Natural frequency 740 Hz

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

6-32 UNC base thread

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 Low Low Range Precision Miniature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads - maximum load to be applied without
damage. 2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life or long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. Standard calibration for tension/compression load cells is in tension
only. or replace, at its option, without charge those items it finds
4. TEDS available with integral cable units only. defective. The foregoing is buyer’s sole remedy and is in lieu
5. This unit calibrated to Imperial (non-Metric) units.
6. Signature calibration only available as inline module. of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
TYPICAL SYSTEM DIAGRAM event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008629-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 Mid
Mid Range Precision Miniature Load Cell
DESCRIPTION
Model 31 mid range precision miniature load cells measure both The Model 31 tension/compression load cell has male threads
tension and compression load forces of 1000 g to 1000 lb. These attachments. High accuracies of 0.15 % to 0.25 % full scale are
models are our highest accuracy, rugged miniature load cells. achieved. Each bonded strain gage unit is built of welded 17-4
Model 31’s welded, stainless steel construction is designed to PH stainless steel for additional ruggedness. All load cells with
eliminate or reduce to a minimum, the effects of off-axis loads. ranges from 1 kg to 10 lb have an electrical balance module in
(The internal construction assures excellent long-term stability the lead wire (approximately 1 in x .087 in thick). This balance
for ranges 1000 grams and above.) A modification permits this module does not have to be the same temperature as the
model to be completely welded for underwater applications. transducer.

FEATURES
• 1000 g to 1000 lb
• mV/V output
• Stainless steel
• Miniature design

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 Mid

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 6
1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, AR 1000 g
250 lb, 500 lb, 1000 lb
AT 5 lb
Linearity 1000 g to 250 lb ±0.15 % full scale
AV 10 lb
Linearity 500 lb to 1000 lb ±0.2 % full scale
Hysteresis 1000 g to 250 lb ±0.15 % full scale
BL 25 lb

Hysteresis 500 lb to 1000 lb ±0.2 % full scale BN 50 lb

Non-repeatability 1000 g ±0.1 % full scale BR 100 lb

Non-repeatability
±0.05 % full scale
CN 250 lb
5 lb to 1000 lb
CR 500 lb
Tolerance on output 1000 g 1.5 mV/V (nominal)
CV 1000 lb
Tolerance on output
2 mV/V
5 lb to 1000 lb
Operation Tension/compression 3 WIRING CODES
Resolution Infinite Cable Unamplified
Red (+) excitation

ENVIRONMENTAL SPECIFICATIONS Black (-) excitation

Characteristic Measure Green (-) output

Temperature, operating -53 °C to 121 °C [-65 °F to 250 °F] White (+) output

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]


Storage temperature -73 °C to 148 °C [-100 °F to 300 °F] DEFLECTIONS AND RINGING FREQUENCIES
Temperature effect, zero 0.005 % full scale/°F Capacity Deflection at full Ringing fre- Weight
Temperature effect, span 0.005 % full scale/°F (lb) scale (in) quency (Hz) (g)
1000 g to 0,03 mm [0.001 in] 3000 Hz 21 g
10 lb
ELECTRICAL SPECIFICATIONS
25 lb to 100 0,03 mm [0.001 in] 10000 Hz 63 g
Characteristic Measure lb
Strain gage type Bonded foil 250 lb to 0,04 mm [0.0015 in] 12000 Hz 80 g
Excitation (calibration) 5 Vdc 1000 lb
1 kg to 10 lb
Excitation (calibration) 10 Vdc
25 lb to 1000 lb
Insulation resistance 5000 Mohm @ 50 Vdc
Bridge resistance 350 ohm
Zero balance 1 % max.
Electrical termination (std) Teflon cable (1524 mm [60 in])

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Weight See table
Material 17-4 PH stainless steel
Deflection full scale See table
Natural frequency See table

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Mid Range Precision Miniature Load Cell

MOUNTING DIMENSIONS
Ranges (lb) T H C F A B
1000 g, 5 lb, 10 lb #6-32 UNC 11,43 mm 6,35 mm 1,27 mm 7,87 mm 4,83 mm
[0.45 in] [0.25 in] [0.05 in] [0.31 in] [0.19 in]
25 lb, 50 lb, 100 lb #10-32 UNF 13,21 mm 6,35 mm 0,76 mm 12,7 mm 6,35 mm
[0.52 in] [0.25 in] [0.03 in] [0.50 in] [0.25 in]
250 lb, 500 lb, 1000 lb 1/4-28 UNF 13,21 mm 9,65 mm 0,76 mm 12,7 mm 6,35 mm
[0.52 in] [0.38 in] [0.03 in] [0.50 in] [0.25 in]

OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Load range 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb,
500 lb, 1000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F
compensation 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F
1c. 0 °F to 185 °F 1i. -65 °F to 250 °F
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 ° to 110 °C
Internal 2u. Unamplified, mV/V output
amplifiers
Overload 4a. Overload stops
stops
Electrical 6a. Bendix PTIH-10-6P 6h. Integral cable: Sili-
termination - 6 pin (max. 250 °F)5 cone
6d. Microtec DR-4S-4H 6i. Integral underwater
4 pin cable (max. 180 °F)
6e. Integral cable: 6v. Phoenix connector on
Teflon end of cable
6f. Integral cable: PVC 15d. Connector on end
of cable
Special 9a. 10 point (5 up/5 down) 20 % increments
calibration @ 20 °C
9b. 20 point (10 up/10 down) 10 % increments
@ 20 °C
Special 30a. Compression only calibration, positive in
calibration compression
30b. Tension and compression calibration, posi-
tive in tension
30c. Compression only calibration, negative in
compression
Shock and 44a. Shock and vibration resistance
vibration
Interfaces4 53e. Signature calibration7
53t. TEDS IEEE 1451.4 module

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 Mid Mid Range Precision Miniature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads - maximum load to be applied without
damage. 2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. Standard calibration for tension/compression load cells is in tension
only. or replace, at its option, without charge those items it finds
4. TEDS available with integral cable units only. defective. The foregoing is buyer’s sole remedy and is in lieu
5. Availability varies with range.
6. This unit calibrated to Imperial (non-Metric) units. of all warranties, expressed or implied, including those of
7. Signature calibration only available as inline module. merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
TYPICAL SYSTEM DIAGRAM indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008630-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 High
High Range Precision Miniature Load Cell
DESCRIPTION
Model 31 high range precision miniature load cells measure term stability for ranges 1000 grams and above.) A modification
both tension and compression load forces of 2000 lb to 10000 permits this model to be completely welded for underwater
lb. These models are our highest accuracy, rugged miniature applications. The Model 31 tension/compression load cell has
load cells. Model 31’s welded, stainless steel construction is male threads attachments. High accuracies of 0.15 % to 0.25 %
designed to eliminate or reduce to a minimum, the effects of full scale are achieved. Each bonded strain gage unit is built of
off-axis loads. (The internal construction assures excellent long- welded 17-4 PH stainless steel for additional ruggedness.

FEATURES
• 2000 lb to 10000 lb
• mV/V output
• Stainless steel
• Miniature design
• Stabilized column construction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 High

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 5
2000 lb to 10000 lb DL 2000 lb
Linearity ±0.2 % full scale DN 3000 lb
Hysteresis ±0.2 % full scale DP 4000 lb
Non-repeatability ±0.05 % full scale DR 5000 lb
Tolerance on output 2 mV/V DT 7500 lb
Operation Tension/compression 3
DV 10000 lb
Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS DEFLECTIONS AND RINGING FREQUENCIES


Capacity Deflection at full Ringing Weight
Characteristic Measure
(lb) scale frequency
Temperature, operating -53 °C to 121 °C [-65 °F to 250 °F]
2000 lb, 0.03 mm [0.001 in] 26000 Hz 60 g
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] 3000 lb
Storage temperature -73 °C to 148 °C [-100 °F to 300 °F] 4000 lb, 0.04 mm [0.0015 in] 21000 Hz 125 g
Temperature effect, zero 0.005 % full scale/°F 5000 lb
Temperature effect, span 0.005 % full scale/°F 7500 lb, 0.04 mm [0.0015 in] 17000 Hz 250 g
10000 lb

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 5 Vdc
Insulation resistance 5000 Mohm @ 50 Vdc
Bridge resistance 350 ohm
Zero balance 1 % max.
Electrical termination (std) Teflon cable (1524 mm [60 in])

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Weight See table
Material 17-4 PH stainless steel
Deflection full scale See table
Natural frequency See table

WIRING CODES
Cable Unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Range Precision Miniature Load Cell

MOUNTING DIMENSIONS
Ranges (lb) T ØD C H
2000 lb, 3000 lb 3/8-24 UNF 25,4 mm [1.00 in] 12,7 mm [0.50 in] 18,29 mm [0.72 in]
4000 lb, 5000 lb 1/2-20 UNF 31,75 mm [1.25 in] 16 mm [0.63 in] 23,88 mm [0.94 in]
7500 lb, 10000 lb 3/4-16 UNF 35,05 mm [1.38 in] 22,35 mm [0.88 in] 27,94 mm [1.10 in]

OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Load range 2000 lb, 3000 lb, 4000 lb, 5000 lb, 7500 lb,
10000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F
compensation 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F
1c. 0 °F to 185 °F 1i. -65 °F to 250 °F
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 ° to 110 °C
Internal 2u. Unamplified, mV/V output
amplifiers
Electrical 6e. Integral cable: 6h. Integral cable: Sili-
termination Teflon cone
6d. Microtec DR-4S-4H 6i. Integral underwater
4 pin cable (max. 180 °F)
6f. Integral cable: PVC 6v. Phoenix connector on
6g. Integral cable: end of cable
Neoprene (max.
180 °F)
Bridge 12a. 1000 ohm (foil)
resistance 12b. 5000 ohm (foil)
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Special 30a. Compression only calibration, positive in
calibration compression
30b. Tension and compression calibration, posi-
tive in tension
30c. Compression only calibration, negative in
compression
30d. Tension and compression calibration, posi-
tive in compression
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module4

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 31 High High Range Precision Miniature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads - maximum load to be applied without
damage. 2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. Standard calibration for tension/compression load cells is in tension
only. or replace, at its option, without charge those items it finds
4. TEDS available with integral cable units only. defective. The foregoing is buyer’s sole remedy and is in lieu
5. This unit calibrated to Imperial (non-Metric) units.
6. Signature calibration only available as inline module. of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
TYPICAL SYSTEM DIAGRAM event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008631-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 34
Precision Miniature Load Cell
DESCRIPTION
Model 34 precision miniature load cells measure both tension The Model 34 tension/compression load cell has female threads
and compression load forces of 1000 g to 1000 lb. These attachments. High accuracies of 0.15 % to 0.25 % full scale are
models are our highest accuracy, rugged miniature load cells. achieved. Each bonded strain gage unit is built of welded 17-4
Model 34’s welded, stainless steel construction is designed to PH stainless steel for additional ruggedness. All load cells with
eliminate or reduce to a minimum, the effects of off-axis loads. ranges from 1 kg to 10 lb have an electrical balance module in
(The internal construction assures excellent long-term stability the lead wire (approximately 1 in x .087 in thick). This balance
for ranges 1000 grams and above.) A modification permits this module does not have to be the same temperature as the
model to be completely welded for underwater applications. transducer.

FEATURES
• 1000 g to 1000 lb
• Welded stainless steel
• Rugged, small size
• Tension/compression
• 0.15 %/0.20 % accuracy

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 34

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 6
1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, AR 1000 g
250 lb, 500 lb, 1000 lb
AT 5 lb
Linearity 1000 g to 250 lb ±0.15 % full scale
AV 10 lb
Linearity 500 lb to 1000 lb ±0.2 % full scale
Hysteresis 1000 g to 250 lb ±0.15 % full scale
BL 25 lb

Hysteresis 500 lb to 1000 lb ±0.2 % full scale BN 50 lb

Non-repeatability 1000 g ±0.1 % full scale BR 100 lb

Non-repeatability
±0.05 % full scale
CN 250 lb
5 lb to 1000 lb
CR 500 lb
Tolerance on output 1000 g 1.5 mV/V (nominal)
CV 1000 lb
Tolerance on output
2 mV/V
5 lb to 1000 lb
Operation Tension/compression3 WIRING CODES
Resolution Infinite Cable Unamplified
Red (+) excitation

ENVIRONMENTAL SPECIFICATIONS Black (-) excitation

Characteristic Measure Green (-) output

Temperature, operating -53 °C to 121 °C [-65 °F to 250 °F] White (+) output

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]


Storage temperature -73 °C to 148 °C [-100 °F to 300 °F] DEFLECTIONS AND RINGING FREQUENCIES
Temperature effect, zero 0.005 % full scale/°F Capacity Deflection at full Ringing fre- Weight
Temperature effect, span 0.005 % full scale/°F (lb) scale (in) quency (Hz) (g)
1000 g to 0,03 mm [0.001 in] 1000 Hz 40 g
10 lb [0.09 lb]
ELECTRICAL SPECIFICATIONS
25 lb to 0,03 mm [0.001 in] 3000 Hz 80 g
Characteristic Measure 100 lb [0.18 lb]
Strain gage type Bonded foil 250 lb to 0,05 mm [0.0015 in] 5000 Hz 100 g
Excitation (calibration) 5 Vdc 1000 lb [0.22 lb]
1 kg to 10 lb
Excitation (calibration) 10 Vdc
25 lb to 1000 lb
Insulation resistance 5000 Mohm @ 50 Vdc
Bridge resistance 350 ohm
Electrical termination (std) Teflon cable (1524 mm [5 ft]) with bal-
1000 g to 10 lb ance board
Electrical termination (std) Teflon cable (1524 mm [5 ft])
25 lb to 1000 lb

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Weight See table
Material 17-4 PH stainless steel
Deflection full scale See table
Natural frequency See table

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Miniature Load Cell

MOUNTING DIMENSIONS
Ranges D mm [in] H mm [in] A mm [in] B mm [in] C mm [in] F mm [in] G mm [in] T
1000 g, 5 lb, 10 lb 19,05 [0.75] 44,45 [1.75] 7,87 [0.31] 4,83 [0.19] 4,83 [0.46] 15,24 [0.60] 18,29 [0.72] 1/4-28 UNF
25 lb, 50 lb, 100 lb 25,4 [1.00] 44,45 [1.75] 12,7 [0.50] 6,35 [0.25] 4,83 [0.46] 13,21 [0.52] 18,29 [0.72] 1/4-28 UNF
250 lb, 500 lb, 1000 lb 25,4 [1.00] 50,8 [2.00] 12,7 [0.50] 6,35 [0.25] 4,83 [0.46] 19,05 [0.75] 19,05 [0.75] 1/4-28 UNF

OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Load range 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb,
500 lb, 1000 lb
Temperature 1a. 60 °F to 160 °F 1k. -20 °C to 85 °C
compensation 1b. 30 °F to 130 °F 1m. -25 ° to 110 °C7
1c. 0 °F to 185 °F 1f. 70 °F to 250 °F
1d. -20 °F to 130 °F 1g. 70 °F to 325 °F7
1e. -20 °F to 200 °F 1h. 70 °F to 400 °F7
1j. 0 °C to 50 °C 1i. -65 °F to 250 °F7
Internal 2u. Unamplified, mV/V output
amplifiers
Overload 4a. Overload stops
stops
Electrical 6a. Bendix PTIH-10-6P 6h. Integral cable: Sili-
termination - 6 pin (max. 250 °F)5 cone
6d. Microtec DR-4S-4H 6i. Integral underwater
4 pin cable (max. 180 °F)
6e. Integral cable: 6v. Phoenix connector on
Teflon end of cable
6f. Integral cable: PVC 15d. Connector on end
6g. Integral cable: of cable
Neoprene (max. 180 °F)
Special 9a. 10 point (5 up/5 down) 20 % increments
calibration @ 20 °C
9b. 20 point (10 up/10 down) 10 % increments
@ 20 °C
Special 30a. Compression only calibration, positive in
calibration compression
30b. Tension and compression calibration, posi-
tive in tension
30c. Compression only calibration, negative in
compression
Shock and 44a. Shock and vibration resistance
vibration
Interfaces4 53e. Signature calibration7
53t. TEDS IEEE 1451.4 module

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 34 Precision Miniature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
Honeywell’s standard product warranty applies unless agreed
damage.2
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue order acknowledgement or consult your local sales office for
life for long term use and structural integrity. All structurally critical
specific warranty details. If warranted goods are returned to
applications (overhead loading, etc.) should always be designed
with safety redundant load paths. Honeywell during the period of coverage, Honeywell will repair
3. Standard calibration for tension/compression load cells is in tension or replace, at its option, without charge those items it finds
only. defective. The foregoing is buyer’s sole remedy and is in lieu
4. Option 53e and 53t are external in-line interfaces.
5. Availability varies with range. of all warranties, expressed or implied, including those of
6. This unit calibrated to Imperial (non-Metric) units. merchantability and fitness for a particular purpose. In no
7. Not available with 500 g range. event shall Honeywell be liable for consequential, special, or
indirect damages.
TYPICAL SYSTEM DIAGRAM
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008636-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 34 Semi Precision Miniature Load Cell
Order Code AL312
n 50 g to 500 g
n mV/V Output
n Stainless Steel
n Miniature Design
n Double Diaphragm Construction

Dimensions Wiring Code


Cable/ Unamplified
2x 1/4-28 UNF ø1.00
0.38 in. deep
Red (+) Excitation
Black (-) Excitation
Green (-) Output
0.52 White (+) Output

1.75

0.52 4 conductor, 30 AWG,


Teflon insulated shielded
cable, 5 ft. long with 2”
spring strain relief

Load Ranges................50; 150; 250; 500 g


Performance Linearity................+/- 0.15% Full Scale
Hysteresis................+/- 0.15% Full Scale
Non-Repeatability................+/- 0.1% Full Scale
Tolerance on Output
50 to 150 g................0.1 mV/V/g max.
250 to 500 g................20 mV/V
Operation................Tension/ Compression (note 3)
Resolution................Infinite

Environmental Temperature, Operating................-65° to 250° F


Temperature, Compensated................60° to 160° F
Storage Temperature................-100° to 300° F
Temperature, Effect
Zero................0.015% Full Scale/° F
Span................0.015% Full Scale/° F

Electrical Strain Gage Type................Semiconductor


Excitation (calibration)................5 VDC
Insulation Resistance................5000 Megohms @ 50 VDC
Bridge Resistance................500 Ohms
Zero Balance................1% max.
Electrical Termination (std)................Teflon Cable (5 ft.)

Mechanical Maximum Allowable Load................5 lb. (note 1)


Weight................110 grams
Material................17-4 PH Stainless Steel
Deflection Full Scale................11 kg/ mm
Natural Frequency................400 Hz

1-888-282-9891 www.honeywell.com/sensotec
198
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 34 semi

Typical System Diagram Customer Supplied

Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
Model 34 Semi

In-Line Amplifiers
(Used with unamplified units only)

Amplifier Output
Display Units Universal In-Line Amplifiers
UV +/- 5 VDC
SC500 UV-10 +/- 10 VDC
SC1000 UBP 0 +/- 5 VDC
SC2000 U3W 4-20 mA (3 wire)
SC2001 DIN rail Mount In-Line Amplifiers
SC3004 DV-05 0 +/- 5 VDC (3 wire)
GM DA-05 4-20 mA (3 wire)
NK DV-10 0 +/- 10 VDC (3 wire)
HH

Options Range Codes


Built to Order Built from Scratch
Range Range Code
Load Range 50; 150; 250 grams 500 grams
50 g AJ
1a. 60° to 160° F
1b. 30° to 130° F 150 g AL
1c. 0° to 185° F 250 g AN
Temperature 1d. -20° to 130° F
Compensation 1e. -20° to 200° F 500 g AP
1j. 0° to 50° C
1k. -20° to 85° C
1m. -25° to 110° C
Internal Amplifiers 2u. Unamplified, mV/V output
6f. Integral cable: PVC
6e. Integral cable: Teflon 6g. Integral cable: Neoprene Special Customer
(max. 180° F)
Electrical
6d. Microtec DR-4S-4H 4 pin 6h. Integral cable: Silicone Requirements
Termination 6v. Phoenix connector on end of 6i. Integral underwater cable
cable (max. 180° F) (Consult Factory)
15d. Connector on end of cable
30a. Compression only calibration, OEM Labels
Positive in compression Radiation proof
Special Calibration 30b. Tension and Compression
calibration, Positive in tension Different cable lengths
30c. Compression only calibration,
Negative in compression
Shock & Vibration 44a. Shock and vibration resistance

Interfaces (note 4) 53e. Signature Calibration


53t. T.E.D.S. IEEE 1451.4 Module

Supplied as standard

Notes
1. Allowable Maximum Loads- Maximum load to be applied without damage (note 2).

2. Without Damage- loading to this level will not cause excessive zero shift or
performance degradation. The user must consider fatigue life for long term use and
structural integrity. All structurally critical applications (overhead loading, etc.)
should always be designed with safety redundant load paths.

3. Standard calibration for tension/ compression load cells is in tension only

4. TEDS available with integral cable units only.

How to Order
Combine the order code, the range code and the options code.
Sample Code: AL312 AJ 1b, 30a
Model Code Range Code Options Code

1-888-282-9891 www.honeywell.com/sensotec 199


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 11
Subminiature Load Cell
DESCRIPTION
Model 11 (tension/compression) subminiature load cell is The model achieves a non-linearity and hysteresis of 0.5 % full
designed to measure load ranges from 150 g to 1000 lb. With scale respectively and a frequency response of up to 58 kHz. A
subminiature dimensions, including diameters from .50 in to 0.75 balance module is included in the load cell’s lead wire cable for
in and height of 0.38 in, these units are easily incorporated into zero balance, and should not be removed.
systems having limited space.

FEATURES
• 150 g to 1000 lb
• mV/V output
• Subminiature design
• Single diaphragm construction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 11

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 7
150 g to 1000 lb AL 150 g
Linearity ±0.5 % full scale AN 250 g
Hysteresis ±0.5 % full scale
AP 500 g
Non-repeatability ±0.1 % full scale
AR 1000 g
Tolerance on output
10 mV/V (nominal) AT 5 lb
150 g to 500 g
Tolerance on output AV 10 lb
2 mV/V (nominal)
1000 g to 1000 lb BL 25 lb
Operation Tension/compression3
BN 50 lb
Resolution Infinite
BR 100 lb
Maximum permissible
4 in-lb CN 250 lb
torque 150 g to 100 lb
Maximum permissible CR 500 lb
20 in-lb
torque 250 lb to 1000 lb
CV 1000 lb

ENVIRONMENTAL SPECIFICATIONS WIRING CODES


Characteristic Measure Cable Unamplified
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] Red (+) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] Black (-) excitation
Temperature effect, zero 0.01 % full scale/°F Green (-) output
Temperature effect, span 0.02 % reading/°F White (+) output

ELECTRICAL SPECIFICATIONS MOUNTING DIMENSIONS


Characteristic Measure Ranges ØD T H A B
Strain gage type Semiconductor 150, 250, 500, 12,7 #4-40 7,37 mm 4,83 mm 4,57 mm
150 g to 500 g 1000 g; 5, 10, mm UNC [0.29 in] [0.19 in] [0.18 in]
Strain gage type Bonded foil 25, 50, 100 lb [0.50 in]
1000 g to 1000 lb 250, 500, 19,05 1/4-28 9,65 mm 7,87 mm 7,87 mm
Excitation (calibration) 5 Vdc 1000 lb mm UNF [0.38 in] [0.31 in] [0.31 in]
[0.75]
Insulation resistance 5000 mOhm @ 50 Vdc
Bridge resistance (toler- 500 ohm (nominal)
ance) 150 g to 500 g
Bridge resistance (toler- 350 ohm (nominal)
ance) 1000 g to 1000 lb
Zero balance (tolerance) ±3 % of full scale (nominal)
Shunt calibration data Included
Electrical termination (std) 1,83 m [5 ft] cable with balance board4

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load See table1
Weight See table
Material Stainless steel
Deflection @ full scale See table
Natural frequency See table

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Subminiature Load Cell

DEFLECTIONS AND RINGING FREQUENCIES


Capacity Deflection at full Ringing frequency Weight Weight with cable Max. allowable load1
scale (10-3 in) (kHz) (% FS)
150 g 0.05 10 5 g [0.011 lb] 13 g [0.029 lb] 500
250 g 0.04 14 5 g [0.011 lb] 13 g [0.029 lb] 500
500 g 0.03 22 5 g [0.011 lb] 13 g [0.029 lb] 500
1000 g 0.7 8 5 g [0.011 lb] 13 g [0.029 lb] 150
5 lb 0.6 11 5 g [0.011 lb] 13 g [0.029 lb] 150
10 lb 0.6 17 5 g [0.011 lb] 13 g [0.029 lb] 150
25 lb 0.5 24 5 g [0.011 lb] 13 g [0.029 lb] 150
50 lb 0.5 34 5 g [0.011 lb] 13 g [0.029 lb] 150
100 lb 0.5 48 5 g [0.011 lb] 13 g [0.029 lb] 150
250 lb 0.6 25 19 g [0.041 lb] 27 g [0.06 lb] 150
500 lb 0.7 33 19 g [0.041 lb] 27 g [0.06 lb] 150
1000 lb 1.0 40 19 g [0.041 lb] 27 g [0.06 lb] 150

OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load 150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb,
range 100 lb, 250 lb, 500 lb, 1000 lb
Tempera- 1a. 60 °F to 160 °F
ture 1b. 30 °F to 130 °F
compen- 1c. 0 °F to 185 °F
sation 1e. -20 °F to 200 °F5
1f. 70 °F to 250 °F5
Internal 2u. Unamplified, mV/V output
amplifiers
Electrical 5 ft integral cable with balance board4
termina- 6a. Bendix PTIH-10-6P - (or equivalent) 6 pin (max.
tion 120 °C) on end of cable
6e. Integral cable: Teflon
6v. Phoenix connector on end of cable
Electrical 15d. Connector on end of cable
termina-
tion orien-
tation
Special 30a. Compression testing only, positive in compres-
calibration sion
30b. Tension and compression testing only, positive in
tension
30c. Compression testing only, negative in compres-
sion
Shock and 44a. Shock and vibration resistance
vibration

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 11 Subminiature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. Standard calibration for tension/compression load cells is tension
only. or replace, at its option, without charge those items it finds
4. A small, 2 in circuit board is included in the cable, 2 ft from the load defective. The foregoing is buyer’s sole remedy and is in lieu
cell. Do not remove this board.
5. Only for ranges greater-than-or-equal-to 1000 g. of all warranties, expressed or implied, including those of
6. Specifications may vary with this option. merchantability and fitness for a particular purpose. In no
7. This unit calibrated to Imperial (non-Metric) units.
event shall Honeywell be liable for consequential, special, or
indirect damages.
TYPICAL SYSTEM DIAGRAM
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008637-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 13
Subminiature Load Cell
DESCRIPTION
Model 13 (compression only) subminiature load cell is designed frequency response and low deflection to achieve a combined
to measure load ranges from 150 g to 1000 lb. With subminiature non-linearity and hysteresis of 0.25 % to 0.5 % full scale. A
dimensions, including diameters from 0.38 in to 0.75 in and balance module is included in the load cell’s lead wire cable for
heights of 0.13 in to 0.25 in, these units are easily incorporated temperature compensation and should not be removed.
into systems having limited space. Model 13 combines high

FEATURES
• 150 g to 1000 lb
• 0.7 % accuracy
• mV/V output
• Subminiature design
• Single diaphragm construction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 13
PERFORMANCE SPECIFICATIONS RANGE CODES
Characteristic Measure Range codes Range
Load ranges6 150 g, 250 g, 500 g, 1000 g, 5 lb, AL 150 g
10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb,
1000 lb AN 250 g

Linearity ±0.5 % full scale AP 500 g

Hysteresis ±0.5 % full scale AR 1000 g


Non-repeatability ±0.1 % full scale AT 5 lb
Tolerance on output AV 10 lb
15 mV/V (nominal)
150 g to 500 g
BL 25 lb
Tolerance on output 1000 g 1.5 mV/V (nominal)
Tolerance on output
BN 50 lb
2 mV/V (nominal)
5 lb to 1000 lb BR 100 lb
Operation Compression only CN 250 lb
Resolution Infinite CR 500 lb

CV 1000 lb
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure WIRING CODES
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] Cable Unamplified
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] Red (+) excitation
Temperature effect, zero 0.01 % full scale/°F Black (-) excitation
Temperature effect, span 0.02 % reading/°F Green (-) output
White (+) output

ELECTRICAL SPECIFICATIONS
Characteristic Measure DEFLECTIONS AND RINGING FREQUENCIES
Strain gage type Semiconductor Capac- Deflec- Weight Weight with Max. al-
150 g to 500 g ity (lb) tion at cable lowable
Strain gage type Bonded foil
full scale load1 (%
1000 g to 1000 lb
(10-3 in) FS)
150 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500
Excitation (calibration) 5 Vdc
250 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500
Insulation resistance 5000 mOhm @ 50 Vdc
500 g 0.08 1 g [0.002 lb] 9 g [0.019 lb] 500
Bridge resistance (toler- 500 ohm (nominal)
ance)150 g to 500 g 1000 g 0.05 1 g [0.002 lb] 9 g [0.019 lb] 150
Bridge resistance (toler- 350 ohm (nominal) 5 lb 0.5 1 g [0.002 lb] 9 g [0.019 lb] 150
ance)1000 g to 1000 lb 10 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150
Zero balance (tolerance) ±3 % of full scale (nominal) 25 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150
Shunt calibration data Included 50 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150
Electrical termination (std) 1,83 m [5 ft] integral cable with balance 100 lb 0.4 3 g [0.006 lb] 11 g [0.024 lb] 150
board3
250 lb 0.5 3 g [0.006 lb] 11 g [0.024 lb] 150
MECHANICAL SPECIFICATIONS 500 lb 0.5 10 g [0.022 lb] 18 g [0.039 lb] 150
Characteristic Measure 1000 lb 0.6 10 g [0.022 lb] 18 g [0.039 lb] 150
Maximum allowable load See table
Weight See table
Material Stainless steel
Deflection @ full scale See table

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Subminiature Load Cell
MOUNTING DIMENSIONS
Ranges D1 D2 H B SR
150, 250, 500, 2,29 mm [0.09 in] 9,65 mm [0.38 in] 3,3 mm [0.13 in] 0,69 mm [0.027 in] 6,35 mm [0.25 in]
1000 g; 5, 10, 25, 50 lb
100, 250 lb 3,05 mm [0.12] 12,7 mm [0.50 in] 3,81 mm [0.15 in] 0,51 mm [0.020 in] 12,7 mm [0.50 in]
500 lb, 1000 lb 6,35 mm [0.25 in] 19,05 mm [0.75] 6,35 mm [0.25 in] 0,64 mm [0.025 in] 12,7 mm [0.50 in]

OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load range 150, 250, 500 g,
1000 g; 5, 10, 25, 50, 100, 250, 500, 1000 lb
Temperature 1a. 60 °F to 160 °F 1e. -20 °F to 200 °F
compensa- 1b. 30 °F to 130 °F 1j. 0 °C to 50 °C
tion 1c. 0 °F to 185 °F 1k. -20 °C to 85 °C
1d. -20 °F to 200 °F 1m. -25 ° to 110 °C
Internal 2u. Unamplified, mV/V output
amplifiers
Overload 4a. Overload stops
TYPICAL SYSTEM DIAGRAM stops
Electrical 5 ft integral cable with balance board3
termination 6v. Phoenix connector on end of cable
15d. Connector on end of cable
Special 9a. 10 point (5 up/5 down) 20 % increments @ 68 °F
calibration 9b. 20 point (10 up/10 down) 10 % increments @ 68
°F
Shock and 44a. Shock and vibration resistance
vibration

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 13 Subminiature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
Honeywell’s standard product warranty applies unless agreed
damage.2 Loads described allow for 100 % full scale axial loading
with the bending loads specified. Torque loading maximum is with- to otherwise by Honeywell in writing; please refer to your
out axial or other load. For any other combination, consult factory. order acknowledgement or consult your local sales office for
2. Without damage - loading to this level will not cause excessive zero
specific warranty details. If warranted goods are returned to
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical Honeywell during the period of coverage, Honeywell will repair
applications (overhead loading, etc.) should always be designed or replace, at its option, without charge those items it finds
with safety redundant load paths. defective. The foregoing is buyer’s sole remedy and is in lieu
3. A small, 2 in circuit board is included in the cable, 2 ft from the load
cell. Do not remove this board. of all warranties, expressed or implied, including those of
4. Only for ranges greater-than-or-equal-to 1000 g. merchantability and fitness for a particular purpose. In no
5. Specifications may vary with this option. event shall Honeywell be liable for consequential, special, or
6. This unit calibrated to Imperial (non-Metric) units.
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this datasheet is for
reference only. DO NOT USE this document as product
Find out more installation information.
Honeywell serves its customers • Complete installation, operation and maintenance
through a worldwide network of information is provided in the instructions supplied with
each product.
sales offices, representatives
Failure to comply with these instructions could result in
and distributors. For application
death or serious injury.
assistance, current specifica-
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008641-2-EN IL50 GLO 
April 2009
www.honeywell.com Copyright © 2009 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LFH-7I
Top Hat Subminiature Load Cell
DESCRIPTION
Model LFH-7I subminiature load cell is a low profile force accuracy of ±0.7 % full scale. The top of the load cell is the area
transducer for applications with minimal space and high where the force is applied and the base ring of the load cell
capacity requirements. This transducer utilizes foil strain gages must be placed on a hard, machine-ground flat surface to obtain
to measure compression loads of up to 10,000 lb and achieves optimum accuracy.

FEATURES
• 250 lb to 10000 lb range
• ±0.7 % accuracy
• Stainless steel
• Column construction
• mV/V output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LFH-7I

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 4
250 lb to 10000 lb CN 250 lb
Accuracy ±0.7 % full scale1 CR 500 lb
Tolerance on output 1.5 mV/V to 2.5 mV/V CV 1000 lb
Operation Compression only DL 2000 lb
DN 3000 lb
ENVIRONMENTAL SPECIFICATIONS DP 4000 lb
Characteristic Measure DR 5000 lb
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] DT 7500 lb
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] DV 10000 lb
Storage temperature -70 °C to 149 °C [-100 °F to 300 °F]
Temperature effect, zero 0.01 % full scale/°F
DEFLECTIONS AND RINGING FREQUENCIES
Temperature effect, span 0.01 % full scale/°F (nominal)
Capacity Deflection at full Ringing fre- Weight
scale quency (kHz)
ELECTRICAL SPECIFICATIONS 250 lb 0,0127 mm [0.0005 in] 30 10 g
[0.022 lb]
Characteristic Measure
500 lb 0,0127 mm [0.0005 in] 34 10 g
Strain gage type Bonded foil
[0.022 lb]
Excitation (calibration) 5 Vdc
1000 lb 0,03 mm [0.001 in] 37 10 g
Insulation resistance 5000 mOhm @ 50 Vdc [0.022 lb]
Bridge resistance 350 ohm 2000 lb 0,03 mm [0.001 in] 44 10 g
Zero balance 5 % max. [0.022 lb]
Electrical termination (std) Cable (1,83 m [5 ft]) 3000 lb 0,03 mm [0.001 in] 46 10 g
[0.022 lb]
5000 lb 0,03 mm [0.001 in] 47 30 g
MECHANICAL SPECIFICATIONS [0.066 lb]

Characteristic Measure 7500 lb 0,038 mm [0.0015 in] 44 30 g


[0.066 lb]
Maximum allowable load 150 % full scale 2

10000 lb 0,04 mm [0.002 in] 40 30 g


Weight See table [0.066 lb]
Material 17-4 PH stainless steel
Deflection full scale See table
Natural frequency See table

WIRING CODES
Cable Unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Top Hat Subminiature Load Cell

MOUNTING DIMENSIONS
Ranges ØD1 mm [in] ØD2 mm [in] H mm [in] F mm [in] W mm [in]
250 lb 12,7 [0.50] 6,86 [0.27] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43]
500 lb 12,7 [0.50] 7,11 [0.28] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43]
1000 lb 12,7 [0.50] 7,87 [0.31] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43]
2000 lb 12,7 [0.50] 10,41 [0.41] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43]
3000 lb 12,7 [0.50] 11,43 [0.45] 9,65 [0.38] 3,3 [0.13] 11,68 [0.46]
5000 lb 16,00 [0.63] 13,46 [0.53] 15,24 [0.60] 5,84 [0.23] 12,95 [0.51]
7500 lb 22,35 [0.88] 16,00 [0.63] 16,00 [0.63] 13,72 [0.54] 16,00 [0.63]
10000 lb 22,35 [0.88] 16,00 [0.63] 16,00 [0.63] 13,72 [0.54] 16,00 [0.63]

OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000
range lb
Tempera- 1a. 60 °F to 160 °F
ture 1b. 30 °F to 130 °F
compen- 1c. 0 °F to 185 °F
sation 1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output
amplifiers
Electrical 6e. Integral cable: Teflon
termina- 6h. Integral cable: Silicone
tion 6v. Phoenix connector on end of cable
15d. Connector on end of cable
Special 9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
calibration 9b. 20 point (10 up/10 down) 10 % increments @ 70 °F
Shock and 44a. Shock and vibration resistance
vibration

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LFH-7I Top Hat Subminiature Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Accuracies stated are expected for best-fit straight line for all errors
including linearity, hysteresis and repeatability through zero. Honeywell’s standard product warranty applies unless agreed
2. Allowable maximum loads – maximum load to be applied without to otherwise by Honeywell in writing; please refer to your
damage.3
3. Without damage - loading to this level will not cause excessive zero order acknowledgement or consult your local sales office for
shift or performance degradation. The user must consider fatigue specific warranty details. If warranted goods are returned to
life for long term use and structural integrity. All structurally critical
Honeywell during the period of coverage, Honeywell will repair
applications (overhead loading, etc.) should always be designed
with safety redundant load paths. or replace, at its option, without charge those items it finds
4. This unit calibrated to Imperial (non-Metric) units. defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
TYPICAL SYSTEM DIAGRAM merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008640-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 45
Fatigue Rated Universal Load Cell
DESCRIPTION
Model 45 Ultra Precision Fatigue-Rated Load Cell offers a low Model 45 is available in ranges 250 lb through 100,000 lb. and
profile design for both tension and compression applications. mounting dimensions are universally interchangeable within the
The all-welded stainless steel construction and stabilizing test and measurement industry. Options include hi-level outputs
diaphragms provide the same ruggedness which has made our of 4 mA to 20 mA or 0 Vdc to 5 Vdc as well as weatherproof or
Model 41 and 43 pancake type load cells so successful. The submersible cable configurations.

FEATURES
• Up to 0.04 % accuracy (see specification table for specific
range)
• 250 lb to 100000 lb
• Long fatigue life
• Intrinsically safe available (2N option only)12
• CE approved13

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 45

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Available ranges Range Available ranges
Load ranges 14
250 lb to 100000 lb Code Code
Accuracy Linearity Hysteresis CN 250 lb DW 12500 lb
(static er- CR 500 lb EM 25000 lb
ror band)1,2
CV 1000 lb EP 50000 lb
250 lb to 1000 lb ±0.04 % full ±0.04 % full ±0.03 % full
scale scale scale DM 2500 lb ET 100000 lb

2500 lb to 50000 lb ±0.05 % full ±0.05 % full ±0.05 % full DR 5000 lb


scale scale scale
100000 lb ±0.06 % full ±0.05 % full ±0.05 % full BASE PLATE ORDER INFORMATION
scale scale scale
Ranges Base plate Base plate Load button
Non-repeatability ±0.02 % full scale
order code weight kg order code
Output 2 mV/V [lb]
Tolerance on output ±1 % full scale 250 lb to 1000 lb AA229 1,59 [3.5] AA290
Creep in 20 min. (max.) 0.01 % 2500 lb to AA229 1,59 [3.5] AA290
5000 lb

ENVIRONMENTAL SPECIFICATIONS 12500 lb to AA230 4,99 [11] AA291


25000 lb
Characteristic Measure
50000 lb AA231 9,07 [20] AA292
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
100000 lb AA232 27,67 [61] AA293
Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F]
Temperature effect, zero 0.0008 % full scale/°F
Temperature effect, span 0.0008 % reading/°F
WIRING CODES
Connector Unamplified
A (+) excitation
ELECTRICAL SPECIFICATIONS
B (+) output
Characteristic Measure
C (-) output
Strain gage type Foil
D (-) excitation
Excitation (calibration) 10 Vdc
E no connection
Excitation (acceptable) 20 Vdc
F no connection
Insulation resistance 5000 mOhm @ 50 V
Bridge resistance 350 ohm (nominal)8
(tolerance) DEFLECTIONS AND RINGING FREQUENCIES
Zero balance (tolerance) ±1 % full scale
Capacity (lb) Deflection Natural ring- Weight g [lb]
Shunt calibration data Included @ full scale ing frequen-
Electrical termination (std) PC02A-10-6P (10-3 in) cy (Hz)
Mating connector PC06A-10-6S 250 1.5 2400 1406,1 [3.1]
(not included) 500 1.5 2400 1406,1 [3.1]
1000 1.5 3400 1406,1 [3.1]
MECHANICAL SPECIFICATIONS 2500 1 6800 1451,5 [3.2]
Characteristic Measure 5000 1 9100 1451,5 [3.2]
Maximum allowable load 200 % FS 3, 9
12500 2 5700 3994,6 [8.8]
Weight See table
25000 2 7000 3994,6 [8.8]
Case material Stainless steel
50000 2 6300 9979 [22]
Life cycles (approx.) > 108 cycles fully reversed
100000 2.5 4500 24947,58 [55]
Deflection See table
Natural frequency See table

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fatigue Rated Universal Load Cell

INTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2b put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA ±10 V @ 45 mA
Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
to 32 Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protec- Yes Yes Yes Yes Yes Yes
tion
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
(std)5 B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: cable5,6,7 R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.
TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 45

OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Load ranges 250, 500, 1000, 2500, 5000, 12500, 2500, 50000,
100000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F16
compensation 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F16
1c. 0 °F to 185 °F 1i. -65 °F to 250 °F16
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal ampli- 2b. ±5 Vdc output 2n (2N) 4 mA to 20 mA
fiers 2c. 0 Vdc to 5 Vdc (two-wire) intrinsically
2j. 4 mA to 20 mA safe15
(three-wire) output 2t. 0 Vdc to 10 Vdc
2k. 4 mA to 20 mA (two- output
wire)15 2u. Unamplified, mV/V
output
Internal 3d. Remote buffered shunt calibration
amplifier
enhancements
Electrical PC02A-10-6P
termination 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max.
250 °F)
6b. MS connector MS3102E-14S-6P (mates with
MS3106E-14S-6S) (max. 160 °F)17
Shunt 8a. Precision internal resistor16
calibration
Special 9c. ASTM E-74 calibration
calibration 30a. Compression only calibration, positive in
compression
30b. Tension and compression calibration, posi-
tive in tension
30c. Compression only calibration, negative in
compression
30d. Tension and compression calibration, posi-
tive in compression
Bridge type 31a. Dual bridge
11c. Square and symmetrical bridge16
Electrical 15a. Horizontal electrical exit port orientation
connector
orientation
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration16
53t. TEDS IEEE 1451.4 module11

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fatigue Rated Universal Load Cell

MOUNTING DIMENSIONS
LOAD CELL Ø D1 mm [in] H mm [in] T ØB mm [in] N mm [in] F1
Ranges lb
250, 500, 1000, 104,65 [4.12] 34,8 [1.37] 5/8-18 UNF-3B 34,0 [1.34] 3,05 [0.12] 9/32 in dia.,
2500, 5000 8 holes eq. sp., 3.50 B.C.
12500, 25000 153,92 [6.06] 44,45 [1.75] 1 1/4-12 UNF-3B 67,31 [2.65] 3,05 [0.12] 13/32 in dia., 12 holes eq. sp., 5.125
B.C.
50000 203,2 [8.00] 63,5 [2.50] 1 3/4-12 UNF-3B 95,50 [3.76] 6,35 [0.25] 17/32 in dia.,
16 holes eq. sp., 6.50 B.C.
100000 279,4 [11.00] 88,9 [3.50] 2 3/4-8 UNF-3B 122,17 [4.81] 12,7 [0.50] 11/16 in dia.,
16 holes eq. sp., 9.00 B.C.

PULL PLATE Order code ØD2 mm L mm [in] T ØG mm F2


Ranges lb [in] [in]
250, 500, 1000, AA229 104,65 [4.12] 28,45 [1.12] 5/8-18 UNF-3B 31,75 [1.25] 1/4-28, 8 holes eq. sp., 3.50 B.C.
2500, 5000
12500, 25000 AA230 153,92 [6.06] 44,45 [1.75] 1 1/4-12 UNF-3B 57,15 [2.25] 3/8-24, 12 holes eq. sp., 5.125 B.C.
50000 AA231 203,2 [8.00] 50,8 [2.00] 1 3/4-12 UNF-3B 76,2 [3.00] 1/2-20, 16 holes eq. sp., 6.50 B.C.
100000 AA232 279,4 [11.00] 76,2 [3.00] 2 3/4-8 UNF-3B 114,3 [4.50] 5/8-18, 16 holes eq. sp., 9.00 B.C.

Honeywell • Sensing and Control 5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 45 Fatigue Rated Universal Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Static error band is the recommended performance specifica-
tion. The static error band is calculated as the best fit straight line Honeywell’s standard product warranty applies unless agreed
through zero, including the effects of non-linearity, hysteresis and to otherwise by Honeywell in writing; please refer to your
non-repeatability.
2. Values noted are typical values but fall within the static error. order acknowledgement or consult your local sales office for
3. Allowable maximum loads – maximum load to be applied without specific warranty details. If warranted goods are returned to
damage.4
4. Without damage - loading to this level will not cause excessive zero Honeywell during the period of coverage, Honeywell will repair
shift or performance degradation. The user must consider fatigue or replace, at its option, without charge those items it finds
life for long term use and structural integrity. All structurally critical
defective. The foregoing is buyer’s sole remedy and is in lieu
applications (overhead loading, etc.) should always be designed
with safety redundant load paths. of all warranties, expressed or implied, including those of
5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal merchantability and fitness for a particular purpose. In no
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire
units) or 80 % (voltage amplified units) of full scale output for quick event shall Honeywell be liable for consequential, special, or
calibration. Shunt calibration comes standard with internal amplifier indirect damages.
option 2c, 2t and 2j.
6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; While we provide application assistance personally, through our
W=White; G=Green. Color specifying cable and number or letter
specifying connector. literature and the Honeywell web site, it is up to the customer to
7. No mating connector necessary for cable option. determine the suitability of the product in the application.
8. 250 lb. range has 700 ohm bridge resistance.
9. Off axis loading maximum allowable 50 % full scale. Specifications may change without notice. The information we
10. Internal amplifier for ranges less than 12,500 lb may increase in
height. supply is believed to be accurate and reliable as of this printing.
11. Consult factory for TEDS availability with amplified models. However, we assume no responsibility for its use.
12. Range dependent; consult factory. Termination dependent; consult
factory. For more information about Sensing and Control products, visit
13. Internal amp and termination dependent; consult factory.
14. This unit calibrated to Imperial (non-Metric) units. www.honeywell.com/sensing or call +1-815-235-6847
15. 5000 ohm bridge required. Email inquiries to info.sc@honeywell.com
16. Cannot be used with amplified option.
17. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008612-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 47
Fatigue Rated Ultra Precision
Universal Load Cell
DESCRIPTION
Model 47 Ultra Precision Fatigue Rated Load Cell offers a low Model 47 is available in ranges 250 lb through 100,000 lb. and
profile design for both tension and compression applications. mounting dimensions are universally interchangeable within the
The all welded stainless steel construction and stabilizing industry. Options include hi-level outputs of 4 mA to 20 mA or
diaphragms provide the same ruggedness which has made our 0 Vdc to 5 Vdc as well as weatherproof or submersible cable
Model 41 and 43 pancake type load cells so successful. The configurations.

FEATURES
• Accuracy up to 0.02 % (see specification table for specific
range)
• 250 lb to 100000 lb
• Long fatigue life
• Pull plate attached
• Intrinsically safe available (2N option only)12
• CE approved13

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 47

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Available ranges Range Available ranges
Load ranges 14
250 lb to 100000 lb Code Code
Accuracy Linearity Hysteresis CN 250 lb DW 12500 lb
(static er- CR 500 lb EM 25000 lb
ror band)1,2
CV 1000 lb EP 50000 lb
250 lb to 1000 lb ±0.02 % full ±0.02 % full ±0.02 % full
scale scale scale DM 2500 lb ET 100000 lb

2500 lb to 5000 lb ±0.03 % full ±0.03 % full ±0.04 % full DR 5000 lb


scale scale scale
12500 lb to 50000 lb ±0.04 % full ±0.04 % full ±0.05 % full
scale scale scale WIRING CODES
100000 lb ±0.05 % full ±0.05 % full ±0.05 % full Connector Unamplified
scale scale scale
A (+) excitation
Non-repeatability ±0.01 % full scale
B (+) output
Output 2.0 mV/V
C (-) output
Tolerance on output ±1 % full scale
D (-) excitation
Creep in 20 min. (max.) 0.01 %
E no connection
F no connection
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
DEFLECTIONS AND RINGING FREQUENCIES
Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F] Capacity (lb) Deflection Natural ring- Weight g [lb]
@ full scale ing frequen-
Temperature effect, zero 0.0008 % full scale/°F (10-3 in) cy (Hz)
Temperature effect, span 0.0008 % reading/°F 250 1.5 2400 2,99 [6.6]
500 1.5 2400 2,99 [6.6]
ELECTRICAL SPECIFICATIONS 1000 1.5 3400 2,99 [6.6]
Characteristic Measure 2500 1 6800 3,04 [6.7]
Strain gage type Foil 5000 1 9100 3,04 [6.7]
Excitation (calibration) 10 Vdc 12500 2 5700 8,98 [19.8]
Excitation (acceptable) 20 Vdc 25000 2 7000 8,98 [19.8]
Insulation resistance 5000 mOhm @ 50 V
50000 2 6300 19,05 [42]
Bridge resistance 350 ohm (nominal)8
100000 2.5 4500 52,62 [116]
(tolerance)
Zero balance (tolerance) ±1 % full scale
Shunt calibration data Included
Electrical termination (std) PC02A-10-6P
Mating connector PC06A-10-6S
(not included)

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 200 % FS 3, 9
Weight See table
Case material Stainless steel
Life cycles (approx.) > 108 cycles fully reversed
Deflection See table
Natural frequency See table

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fatigue Rated Ultra Precision Universal Load Cell

INTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2b put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA ±10 V @ 45 mA
Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
to 32 Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protec- Yes Yes Yes Yes Yes Yes
tion
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
(std)5 B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: cable5,6,7 R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.
TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 47

OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honey-
well.com/TMsensor-ship for updated listings.
Load ranges 250, 500, 1000, 2500, 5000, 12500, 2500, 50000,
100000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F16
compensation 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F16
1c. 0 °F to 185 °F 1i. -65 °F to 250 °F16
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal ampli- 2b. ±5 Vdc output 2n (2N) 4 mA to 20 mA
fiers 2c. 0 Vdc to 5 Vdc (two-wire) intrinsi-
2j. 4 mA to 20 mA cally safe15
(three-wire) output 2t. 0 Vdc to 10 Vdc
2k. 4 mA to 20 mA (two- output
wire)15 2u. Unamplified, mV/V
output
Electrical 6a. Bendix PTIH-10-6P 6h. Integral cable:
termination (or equivalent) 6-pin Silicone
(max. 250 °F) 6i. Integral underwater
6b. MS connector cable
MS3102E-14S- 6j. 1/2-14 conduit
6P (mates with fitting with 5 ft of
MS3106-14S 6P) 4 conductor PVC
(max. 160 °F)17 cable
6e. Integral cable: 6q. Molded integral ca-
Teflon ble: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector
6g. Integral cable: on end of cable
Neoprene6 15d. Connector on end
of cable
Shunt 8a. Precision internal resistor16
calibration
Special 9a. 10 point (5 up/5 down) 20 % increments @ 70
calibration °F
9b. 20 point (10 up/10 down) 10 % increments @
70 °F
9c. ASTM E-74 calibration
9e. CE mark
30a. Compression only calibration, positive in com-
pression
30b. Tension and compression calibration, positive
in tension
30c. Compression only calibration, negative in
compression
30d. Tension and compression calibration, positive in
compression
Bridge type 31a. Dual bridge
11a. Square bridge16
11c. Square and symmetrical bridge16
Bridge 12b. 5000 ohm (foil) (max 250 °F)
resistance
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation

Shock and 44a. Shock and vibration resistance


vibration
Interfaces 53e. Signature calibration16
53t. TEDS IEEE 1451.4 module11

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fatigue Rated Ultra Precision Universal Load Cell

MOUNTING DIMENSIONS
LOAD CELL Ø D1 mm [in] H mm [in] T ØB mm [in] N mm [in] ØG mm [in]
Ranges lb
250, 500, 1000, 104,65 [4.12] 34,8 [1.37] 5/8-18 UNF-3B 34,0 [1.34] 3,05 [0.12] 31,75 [1.25]
2500, 5000
12500, 25000 153,92 [6.06] 44,45 [1.75] 1 1/4-12 UNF-3B 67,31 [2.65] 3,05 [0.12] 57,15 [2.25]
50000 203,2 [8.00] 63,5 [2.50] 1 3/4-12 UNF-3B 95,50 [3.76] 6,35 [0.25] 76,2 [3.00]
100000 279,4 [11.00] 88,9 [3.50] 2 3/4-8 UNF-3B 122,17 [4.81] 12,7 [0.50] 114,3 [4.50]

Honeywell • Sensing and Control 5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 47 Fatigue Rated Ultra Precision Universal Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Static error band is the recommended performance specifica-
tion. The static error band is calculated as the best fit straight line Honeywell’s standard product warranty applies unless agreed
through zero, including the effects of non-linearity, hysteresis and to otherwise by Honeywell in writing; please refer to your
non-repeatability.
2. Values noted are typical values but fall within the static error. order acknowledgement or consult your local sales office for
3. Allowable maximum loads – maximum load to be applied without specific warranty details. If warranted goods are returned to
damage.4
4. Without damage - loading to this level will not cause excessive zero Honeywell during the period of coverage, Honeywell will repair
shift or performance degradation. The user must consider fatigue or replace, at its option, without charge those items it finds
life for long term use and structural integrity. All structurally critical
defective. The foregoing is buyer’s sole remedy and is in lieu
applications (overhead loading, etc.) should always be designed
with safety redundant load paths. of all warranties, expressed or implied, including those of
5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal merchantability and fitness for a particular purpose. In no
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire
units) or 80 % (voltage amplified units) of full scale output for quick event shall Honeywell be liable for consequential, special, or
calibration. Shunt calibration comes standard with internal amplifier indirect damages.
option 2c, 2t and 2j.
6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; While we provide application assistance personally, through our
W=White; G=Green. Color specifying cable and number or letter
specifying connector. literature and the Honeywell web site, it is up to the customer to
7. No mating connector necessary for cable option. determine the suitability of the product in the application.
8. 250 lb range has 700 ohm bridge resistance.
9. Off axis loading maximum allowable 50% full scale. Specifications may change without notice. The information we
10. Internal amplifier for ranges less than 12500 lb may increase in
height. supply is believed to be accurate and reliable as of this printing.
11. Consult factory for TEDS availability with amplified models. However, we assume no responsibility for its use.
12. Range dependent; consult factory. Termination dependent; consult
factory. For more information about Sensing and Control products, visit
13. Internal amp and termination dependent; consult factory.
14. This unit calibrated to Imperial (non-Metric) units. www.honeywell.com/sensing or call +1-815-235-6847
15. 5000 ohm bridge required. Email inquiries to info.sc@honeywell.com
16. Cannot be used with amplified option.
17. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008613-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 73
Precision Fatigue-Rated Low Profile
Load Cell
DESCRIPTION
Model 73 fatigue-rated load cells are engineered for applications scale). Model 73 measures compression only. It must be used
such as materials or product fatigue testing, which involve an on a smooth flat surface to achieve rated specifications. The
extremely large number of cycles or occasional overload condi- load button on Model 73 is an integral part of the load cell and
tions. These fatigue rated load cells have load ranges from 50 cannot be removed or changed. Model 73 utilizes two stabilizing
lbs to 200,000 lbs and achieve a non-linearity of 0.1% full scale. diaphragms, which are welded to the sensing member to reduce
The superior design of these bonded foil, strain gage compres- off-center and side-loading effects.
sion load cells permits a fatigue life of 1 billion cycles (zero to full

Approved Approved Approved


Intrinsically safe amp

FEATURES
• 0.10 % accuracy
• 50 lb to 200000 lb
• mV/V output (standard); 4 mA to 20 mA or 0 Vdc to 5 Vdc
(optional) output
• Stainless steel
• Double diaphragm design
• Enhanced overload capacity
• Intrinsically safe available (2N option only)7
• CE approved8

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 73

PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS


Characteristic Measure Characteristic Measure
Load ranges 9
50 lb to 200000 lb Maximum allowable load 200 % FS2
Non-linearity ±0.1 % full scale Weight See table
Hysteresis ±0.1 % full scale Material 17-4PH stainless steel
Non-repeatability ±0.03 % full scale Life cycles (approx) > 108 cycles fully reversed
Output (tolerance) 2 mV/V ±0.5 % full scale Deflection See table
Operation Compression Natural frequency See table
Resolution Infinite
5-point calibration, 0 %, 50 %, and 100
Standard calibration
% F.S. in compression only
RANGE CODES
Range Available ranges Range Available ranges
ENVIRONMENTAL SPECIFICATIONS Code Code
BN 50 lb DV 10000 lb
Characteristic Measure
BR 100 lb EJ 15000 lb
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
CN 250 lb EL 20000 lb
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
CR 500 lb EN 30000 lb
Temperature effect, zero 0.002 % full scale/°F
CV 1000 lb EP 50000 lb
Temperature effect, span 0.002 % full scale/°F
DL 2000 lb ER 75000 lb
ELECTRICAL SPECIFICATIONS DN 3000 lb ET 100000 lb

Characteristic Measure DP 4000 lb FJ 150000 lb

Strain gage type Bonded foil DR 5000 lb FL 200000 lb

Excitation (calibration) 10 Vdc DT 7500 lb

Insulation resistance 5000 mOhm @ 50 Vdc


Bridge resistance 350 ohm (nominal)
(tolerance) DEFLECTIONS AND RINGING FREQUENCIES
Zero balance (tolerance) ±1 % full scale Capacity (lb) Deflection @ Natural ringing Weight g
full scale (in) frequency (Hz) (lb)
Shunt calibration data Included
50 to 500 0.001 4500 730 [1.6]
Electrical termination (std) PTIH-10-6P
50 lb to 2000 lb 1000 to 2000 0.002 8000 952,54 [2.1]
Electrical termination (std) MS3102E-14S-6P 3000 to 10000 0.002 9000 2948,35
3000 lb to 200000 lb [6.5]
Mating connector PT06A-10-6S or equiv. (AA111) 15000 to 50000 0.003 10000 2993,70
50 lb to 2000 lb (not incl.) [6.6]
Mating connector MS3106A-14S-6S (AA121) 75000 to 100000 0.004 13000 5443,10
3000 to 200000 lb (not incl.) [12.0]
150000 to 200000 0.006 11000 12020,19
[26.5]

WIRING CODES
Connector Unamplified (Std.)
A (+) excitation
B (+) excitation
C (-) excitation
D (-) excitation
E (-) output
F (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Fatigue-Rated Low Profile Load Cell

INTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2a put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal 0 V to 5 V 0 V to 5 V or ±5 V 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA ±10 V @ 45 mA
Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
to 32 Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protec- Yes Yes Yes Yes Yes Yes
tion
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
(std)4 B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: cable4,5,6 R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS2


Capacity (lb) Side load Bending Torque
(% FS) (lb-in) (lb-ft)
50 to 500 75 % 60 % 35 %
1000 to 2000 45 % 35 % 35 %
3000 to 10000 30 % 30 % 35 %
15000 to 50000 30 % 30 % 25 %
75000 to 100000 30 % 30 % 15 %
150000 to 200000 30 % 30 % 15 %

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 73
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please
see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000, 150000, 200000 lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F12
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F12
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F12
1d. -20 °F to 130 °F 1j. 0 °F to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2b. Four-wire, 0 Vdc to 5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe11
amplifiers 2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
2j. 4 mA to 20 mA (three-wire) output 2u. Unamplified, mV/V output
2k. 4 mA to 20 mA (two-wire)11
Internal 3a. Input/output isolation10
amplifier en- 3d. Remote buffered shunt calibration8
hancements
Electrical 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 °F) 6f. Integral cable: PVC
termination 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S- 6g. Integral cable: Neoprene
6S) (max. 160 °F) (ranges 2000 and above)13 6h. Integral cable: Silicone
6e. Integral cable: Teflon 6i. Integral underwater cable
6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
Shunt 8a. Precision internal resistor12
calibration
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Bridge type 31a. Dual bridge
Zero and 14a. No access to pots
span adjust- 14b. Top access to pots
ment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Special 30a. Compression only, positive output
calibration 9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
9b. 20 point (10 up/10 down) 10 % increments @ 70 °F
9c. ASTM E-74 calibration
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration12
53t. TEDS IEEE 1451.4 module6

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precision Fatigue-Rated Low Profile Load Cell

MOUNTING DIMENSIONS

Ranges D1 mm D2 mm [in] H mm ØF type. G mm A mm A* mm B mm [in] B* mm C mm [in]


lb [in] [in] dia. [in] B.C. [in] [in] [in]
50 to 500 76,2 [3.00] 14,22 [0.56] 29,97 1/4 57,15 20,83 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25]
[1.18] [2.250] [0.82]
1000 to 88,9 [3.50] 17,53 [0.69] 29,97 5/16 66,68 20,83 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25]
2000 [1.18] [2.625] [0.82]
3000 to 114,3 38,1 [1.50] 50,8 [2.00] 3/8 46,27 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
10000 [4.50] [3.790] [1.25]
15000 to 114,3 38,1 [1.50] 50,8 [2.00] 3/8 46,27 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
50000 [4.50] [3.790] [1.25]
75000 to 139,7 50,8 [2.00] 55,37 3/8 122,22 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
100000 [5.50] [2.18] [4.812] [1.25]
150000 to 190,5 63,5 [2.50] 68,1 [2.68] 3/8 171,45 31,75 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00]
200000 [7.50] [6.750] [1.25]

* Length of load cell with amplified option (see option codes)


TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 73 Precision Fatigue-Rate Low Profile Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads - maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal amplifier
option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Consult factory for TEDS availability with amplified models.
7. Range dependent; consult factory. Termination dependent; consult While we provide application assistance personally, through our
factory.
8. Internal amp and termination dependent; consult factory. literature and the Honeywell web site, it is up to the customer to
9. This unit calibrated to Imperial (non-Metric) units. determine the suitability of the product in the application.
10. Input/output isolation only available with voltage output (2b or 2c)
amplifier. Specifications may change without notice. The information we
11. 5000 ohm bridge required.
12. Cannot be used with amplified option. supply is believed to be accurate and reliable as of this printing.
13. Cannot be used with options 1c, 1e, 1f, 1g, 1g, or 1i. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008628-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 3149-FR
Low Capacity Fatigue Load Cell
DESCRIPTION
The 3149-FR tension/compression load cells are designed for The sensors have a nominal bridge resistance of 350 ohm and
demanding applications in automotive, aerospace and military can be powered by up to 15 Vac or Vdc. Safe overload range is
markets. 150% of rated capacity.

This model is offered in capacity ratings of 50, 100 and 300 lb. The load cells are offered with optional dual bridge output to
Standard output is 2.0 mV/V with an overall accuracy of 0.05%. provide force feedback and control or redundancy.

FEATURES
• Fatigue rated
• Compact size
• High accuracy
• Tension and compression
• Dual bridge output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3179-FR

PERFORMANCE SPECIFICATIONS MOUNTING DIMENSIONS


Characteristic Measure
OPTIONAL DUAL BRIDGE
Load range 1
50, 100, 300 lbf
Zero balance ±1.0 % of rated output
Non-linearity ±0.05 % of rated output 2.56 R

A
Hysteresis ±0.05 % of rated output 2.36
Non-repeatability ±0.01 % of rated output
Static error band ±0.05 % of rated output
Ø2.75
Creep ±0.03 % (reading in 20 minutes)

ENVIRONMENTAL SPECIFICATIONS Ø0.69


2 PLACES
Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] 0.03, 2 PLACES 1/4-28 UNF, 0.28 DEEP, 2 PLACES
Temperature, compensated -9 °C to 46 °C [15 °F to 115 °F] 1.50 [FOR METRIC VERSION:
m6 X 1.0, 7.1 DEEP, 2 PLACES]
Temperature effect, 0.08 % reading/100 °F
sensitivity TYPICAL SYSTEM DIAGRAM
Temperature effect, zero 0.15 % of rated output/100 °F
In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder
Alarm Panel
ELECTRICAL SPECIFICATIONS Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Characteristic Measure UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC
Excitation (recommended) 10 Vdc UBP 0 +/-5 VDC
U3W 4-20mA (3 wire)
Input resistance 700 ohm, +40/-3.5 ohm U2W 4-20mA (2 wire)
Output resistance 700 ohm ±3.5 ohm DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
Sensitivity (rated output) 2 mV/V (nominal) DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)
Insulation resistance, 5000 mOhm @ 50 Vdc
bridge/case
Honeywell
In-Line Amplifier
Output Input
Serial Number

MECHANICAL SPECIFICATIONS
Display Units
Characteristic Measure
SC500 SC1000 SC2000
Safe overload range 150 % of rated output
SC2001 SC3004
Weight 0.8 lb GM NK HH
7541 7558 7561-PSD
Flexure material Aluminum MODEL 3149FR

WIRING CODES OR
2003.1 lb.
L1 L2 L3 L4
VALUE CLEAR CHAN TARE

Cable UP DOWN SETUP ENTER EXIT

Red (+) excitation


Black (-) excitation Mating Connectors & Cables

Green (+) output 023-LW181-023-LF Mating Connector


7205-76-XX* Mating connector & 6 conductor cable
White (-) output (unamplified unit with sense leads but not shunt cal)
7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)

* XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3179-FR Low Capacity Fatigue Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008620-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3108
Tension/Compression Pancake Load Cell
DESCRIPTION
These general purpose designs have exceptional structural Available in capacities of five and ten pounds, they offer
capability to withstand extraneous loads, such as torque, maximum performance and enhanced accuracy.
bending moments, and side loads. This low-range cell has built- Minimum deflection and compactness make these general-
in temperature compensation. purpose load cells easy to install and use.

FEATURES
• 5 lb to 10 lb range
• 0.05 % accuracy
• Low sensitivity to extraneous loads
• Low deflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3108

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure
In-Line Amplifiers Customer Supplied
Load range 1
5, 10 lb (Used with unamplified units only) Chart Recorder
Non-linearity ±0.01 % of rated output Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.01 % of rated output Computer
UV +/-5 VDC
Repeatability ±0.05 % of rated output UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Output @ rated capacity 2 mV/V ±0.25 % (nominal) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Operation Tension/compression DIN rail Mount In-Line Amplifiers
Resolution Infinite DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) DV10 0 +/- 10 VDC (3 wire)

Honeywell
ENVIRONMENTAL SPECIFICATIONS In-Line Amplifier
Output Input
Serial Number

Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] SC500 SC1000 SC2000
Temperature effect, zero ±0.002 % of rated output/°F SC2001 SC3004
GM NK HH
Temperature effect, output ±0.002 % of reading/°F 7541 7558 7561-PSD
MODEL 3108

ELECTRICAL SPECIFICATIONS
2003.1 lb.
OR
Characteristic Measure VALUE
L1 L2 L3 L4
CLEAR CHAN TARE

Strain gage type Foil


UP DOWN SETUP ENTER EXIT

Excitation (maximum) 20 Vdc or Vac RMS


Mating Connectors & Cables
Insulation resistance > 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm 023-LW181-023-LF Mating Connector
(tolerance) 7205-76-XX* Mating connector & 6 conductor cable
(unamplified unit with sense leads but not shunt cal)
Number of bridges 1 or 2 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
Zero balance ±1.0 % 7205-83-XX* Mating connector & 6 conductor cable
Electrical termination PT02E-10-6P mates with PT06W-10-6S (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)

MECHANICAL SPECIFICATIONS * XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Natural frequency See table

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static over- Shear FX or Bending MX Torque MZ Deflection at Ringing fre-
load capacity FY (lb) or MY (lb-in) (lb-in) nominal load quency (Hz)
(% of nominal limit (in)
capacity)
5 20 150 30 30 3 0.005 500
10 50 150 40 40 4 0.005 900

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]
3108 6,98 [2.75] 0,55 [0.22] 0,32 [0.13] 4,44 [1.75] 5,60 [2.22] - [1/4-28]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in] N cm [in] P cm [in]


1,27 [0.38] 1,10 [0.44] 0,71 [0.28] 3,80 [1.50] 0,16 [0.06] 4,13 [1.63] 2,54 [1.00]

NOTE: the 3108 mounting configuration is similar to the 3397.

A SPANNER WRENCH
HOLE B DIA.
F THD. C DEEP
G DEEP
BOTH ENDS

RECEP.
PTO2E-10-6P
E

DUAL BRIDGE
OPTIONAL

H DIA.
J
C

P
K

L
N DIA.

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3108 Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008621-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3132
Tension/Compression Pancake Load Cell
DESCRIPTION
These general purpose designs have exceptional structural Minimum deflection and compactness make these general-
capability to withstand extraneous loads, such as torque, purpose load cells easy to install and use.
bending moments, and side loads.

Available in capacities of 500 lb to 5000 lb, they offer maximum


performance and enhanced accuracy.

FEATURES
• 500 lb to 5000 lb range
• Low sensitivity to extraneous loads
• Low deflection
• Rugged welded construction
• Built-in temperature compensation

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3132

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure In-Line Amplifiers Customer Supplied
Load range 1
500, 1000, 2000, 3000, 5000 lb (Used with unamplified units only) Chart Recorder
Non-linearity ±0.1 % of rated output Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.1 % of rated output Computer
UV +/-5 VDC
Repeatability ±0.05 % of rated output UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Output @ rated capacity 3 mV/V ±0.25 % (nominal) U3W 4-20mA (3 wire)
Operation Tension/compression U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Resolution Infinite DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) 0 +/- 10 VDC (3 wire)
DV10

Honeywell
ENVIRONMENTAL SPECIFICATIONS In-Line Amplifier
Output Input

Characteristic Measure
Serial Number

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]


Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
SC500 SC1000 SC2000
Temperature effect, zero ±0.002 % of rated output/°F SC2001 SC3004
Temperature effect, output ±0.002 % of reading/°F GM NK HH
7541 7558 7561-PSD
MODEL 3132
ELECTRICAL SPECIFICATIONS
Characteristic Measure 2003.1 lb.
OR L1 L2 L3 L4
Strain gage type Foil VALUE
UP
CLEAR
DOWN SETUP
CHAN
ENTER
TARE
EXIT

Excitation (maximum) 20 Vdc or Vac RMS


Insulation resistance > 5000 mOhm @ 50 Vdc
Mating Connectors & Cables
Bridge resistance 350 ohm
(tolerance) 023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable
Number of bridges 1 or 2 (unamplified unit with sense leads but not shunt cal)
Zero balance ±1.0 % 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
Electrical termination PT02E-10-6P mates with PT06W-10-6S 7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)
MECHANICAL SPECIFICATIONS
Characteristic Measure * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Natural frequency See table

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static over- Shear FX or Bending MX Torque MZ Deflection at Ringing fre-
load capacity FY (lb) or MY (lb-in) (lb-in) nominal load quency (Hz)
(% of nominal limit (in)
capacity)
500 2K 150 1400 2800 1100 0.005 1600
1K 5K 150 2000 3900 1100 0.005 2000
2K 10K 150 2800 5000 1100 0.005 3200
3K 15K 150 3400 5500 1100 0.005 4100
5K 20K 150 4200 5500 1100 0.005 5000

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]
3132 6,65 [2.62] 1,60 [0.63] 8,89 [3.50] 2,54 [1.0] 3,02 [1.19] 4,45 [1.75]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in]


0,64 [0.25] 8,70 [0.34] 5,08 [2.0] 3,33 [1.31] 2,54 [1.0]

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3132 Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008624-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 3140-CS
Tension/Compression Pancake Load Cell
DESCRIPTION
The Model 3140-CS load cell series has been designed as compression load cells can be used when accuracy is a high
a reference standard for calibration labs in automotive, priority requirement. Some advantages of these load cells are:
aerospace, military or industrial markets. These tension/ compact size, high accuracy and availability.

FEATURES
• Enhanced accuracy, up to 0.02 %
• 300 lb to 100000 lb range
• Universal tension and compression loading
• Low profile
• 150 % full scale safe overload capability
• Available in single or optional dual bridge configuration
• Metric sizes available
• Factory installed calibration adapters
• Eccentric load compensated
• High precision base installed

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3140-CS

PERFORMANCE SPECIFICATIONS WIRING CODES


Characteristic Measure Cable
Load range 1
300, 500, 1000, 2000, 5000, 10000, Red (+) excitation
25000, 50000, 100000 Black (-) excitation
Operation Tension/compression Green (+) output
Resolution Infinite White (-) output
Standard calibration Tension (+) and compression (-)
TYPICAL SYSTEM DIAGRAM
300 lb to 5K lb to 25K lb to
2K lb 10K lb 100K lb In-Line Amplifiers Customer Supplied
Non-linearity error ±0.02 % ±0.04 % ±0.04 % (Used with unamplified units only) Chart Recorder
(of full scale) Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis error (of ±0.02 % ±0.04 % ±0.05 %
UV +/-5 VDC Computer
full scale)
UV-10 +/-10 VDC PLC
Non-repeatability (of ±0.005 % ±0.005 % ±0.005 % UBP 0 +/-5 VDC
full scale) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Output @ rated ca- 2.0 mV/V 4.0 mV/V 4.0 mV/V DIN rail Mount In-Line Amplifiers
pacity (nominal) DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)
ENVIRONMENTAL SPECIFICATIONS
Honeywell
Characteristic Measure In-Line Amplifier
Output Input

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] Serial Number

Temperature, compensated -9 °C to 46 °C [15 °F to 115 °F]


Display Units
Temperature effect, zero 0.08 % of rated output/100 °F
SC500 SC1000 SC2000
Temperature effect, output 0.08 % of reading/100 °F MODEL 3143CS SC2001 SC3004
GM NK HH
ELECTRICAL SPECIFICATIONS 7541 7558 7561-PSD

Characteristic Measure
Strain gage type Foil 2003.1 lb.
OR L1 L2 L3 L4
Excitation (maximum) 10 Vdc or Vac RMS VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

Insulation resistance > 5000 mOhm @ 50 Vdc


Input resistance (tolerance) 350 ohm ±40/-3.5 ohm
Mating Connectors & Cables
Output resistance 350 ohm ±3.5 ohm
(tolerance) 023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable
Zero balance (tolerance) ±1.0 %
(unamplified unit with sense leads but not shunt cal)
Electrical termination PT02E-10-6P mates with PT06W-10-6S 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
MECHANICAL SPECIFICATIONS (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
Characteristic Measure (for connection to instrument 7541)
Static overload capacity 150 % of nominal capacity
* XX represents length in feet 100ft maximum
Material Carbon steel ** XX represents length in feet 20ft maximum
Creep ±0.01 %
Off-centered load sensitivity ±0.10 %
300 lb to 2K lb
Off-centered load sensitivity ±0.25 %
5K lb to 100K lb
Side load sensitivity ±0.10 %
300 lb to 2K lb
Side load sensitivity ±0.25 %
5K lb to 100K lb

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM

In-Line Amplifiers Customer Supplied In-Line Amplifiers Customer Supplied


(Used with unamplified units only) Chart Recorder (Used with unamplified units only) Chart Recorder
Alarm Panel Alarm Panel
Amplifier Output Amplifier Output
Universal In-Line Amplifiers Data Acquisition Universal In-Line Amplifiers Data Acquisition
UV +/-5 VDC Computer UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC UBP 0 +/-5 VDC
U3W 4-20mA (3 wire) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire) U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire) DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire) DV10 0 +/- 10 VDC (3 wire)

Honeywell Honeywell
In-Line Amplifier
In-Line Amplifier
Output Input
Serial Number Output Input
Serial Number

Display Units Display Units


SC500 SC1000 SC2000 SC500 SC1000 SC2000
MODEL 3144CS SC2001 SC3004 MODEL 3145CS SC2001 SC3004
GM NK HH GM NK HH
7541 7558 7561-PSD
7541 7558 7561-PSD

2003.1 lb.
OR L1 L2 L3 L4 2003.1 lb.
VALUE CLEAR
OR L1 L2 L3 L4
CHAN TARE
UP DOWN SETUP ENTER EXIT VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

Mating Connectors & Cables


Mating Connectors & Cables
023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable 023-LW181-023-LF Mating Connector
(unamplified unit with sense leads but not shunt cal) 7205-76-XX* Mating connector & 6 conductor cable
7205-75-XX** Mating connector & 4 conductor cable (unamplified unit with sense leads but not shunt cal)
(unamplified unit without sense leads but not shunt cal) 7205-75-XX** Mating connector & 4 conductor cable
7205-83-XX* Mating connector & 6 conductor cable (unamplified unit without sense leads but not shunt cal)
(for connection to instrument 7541) 7205-83-XX* Mating connector & 6 conductor cable
7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)
(for connection to instrument 7541) 7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3140-CS
MOUNTING DIMENSIONS
Model Capacity ØA B in C in D in E in F in G in Ø H in J Thread Ø K in L Thread M in.
(lb) in
3143-CS-300 300 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20 UNF 3A 6.00 1/2-20 UNF 3B 0.88
3143-CS-500 500 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20 UNF 3A 6.00 1/2-20 UNF 3B 0.88
3143-CS-1K 1000 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20 UNF 3A 6.00 1/2-20 UNF 3B 0.88
3143-CS-2K 2000 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20 UNF 3A 6.00 1/2-20 UNF 3B 0.88
3144-CS-5K 5000 4.12 0.13 1.25 2.50 3.44 4.19 0.03 1.25 5/8-18 UNF 3A 6.00 5/8-18 UNF 3B 0.88
3144-CS-10K 10000 4.12 0.13 1.25 2.50 3.44 4.19 0.03 1.25 5/8-18 UNF 3A 6.00 5/8-18 UNF 3B 0.88
3145-CS-25K 25000 6.06 0.13 1.63 3.50 4.94 6.44 0.03 1.25 1¼-12 UNF 3A 6.00 1¼-12 UNF 3B 1.50
3145-CS-50K 50000 6.06 0.13 1.63 3.50 4.94 6.44 0.03 2.25 1¼-12 UNF 3A 6.00 1¼-12 UNF 3B 1.50
3146-CS-100K 100000 8.00 0.25 2.25 4.50 6.13 7.88 0.03 3.00 1¾-12 UNF 3A 12.00 1¾-12 UNF 3B 1.75
RECEP. F
PT02E-10-6P
E

ØK R

ØH
ØA

B L THD.
J THD. C M DEEP

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3140-CS Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
TYPICAL SYSTEM DIAGRAM order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Honeywell during the period of coverage, Honeywell will repair
Chart Recorder
Alarm Panel or replace, at its option, without charge those items it finds
Amplifier Output
Universal In-Line Amplifiers Data Acquisition defective. The foregoing is buyer’s sole remedy and is in lieu
UV +/-5 VDC Computer
PLC of all warranties, expressed or implied, including those of
UV-10 +/-10 VDC
UBP 0 +/-5 VDC merchantability and fitness for a particular purpose. In no
U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire) event shall Honeywell be liable for consequential, special, or
DIN rail Mount In-Line Amplifiers indirect damages.
DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
Honeywell determine the suitability of the product in the application.
In-Line Amplifier
Output Input

Specifications may change without notice. The information we


Serial Number

supply is believed to be accurate and reliable as of this printing.


Display Units
However, we assume no responsibility for its use.
SC500 SC1000 SC2000
MODEL 3146CS SC2001 SC3004 For more information about Sensing and Control products, visit
GM NK HH
7541 7558 7561-PSD www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

OR
2003.1 lb.
L1 L2 L3 L4
WARNING
VALUE
UP
CLEAR
DOWN SETUP
CHAN
ENTER
TARE
EXIT PERSONAL INJURY
• DO NOT USE these products as safety or emergency
Mating Connectors & Cables stop devices or in any other application where failure of
the product could result in personal injury.
023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable Failure to comply with these instructions could result in
(unamplified unit with sense leads but not shunt cal) death or serious injury.
7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541) WARNING
7205-82-XX** Mating connector & 4 conductor cable MISUSE OF DOCUMENTATION
(for connection to instrument 7541)
• The information presented in this catalogue is for
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008626-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 3140-P
Tension/Compression Pancake Load Cell
DESCRIPTION
Designed for general purpose use in demanding applications in
automotive, aerospace, and military applications. Some advan-
tages of these tension/compression load cells include compact
size, high accuracy, and cost efficiency. The 3140-P has smaller
maximum off-center load and moment error than the standard
3140 Series.

FEATURES
• Static error band 0.02 % to 0.04 %
• English threads
• Enhanced accuracy version of standard 3140 Series
• Low profile
• Low sensitivity to magnetic fields
• Output to 4 mV/V

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3140-P

PERFORMANCE SPECIFICATIONS WIRING CODES


Characteristic Measure Cable
Load range 1
300 lb, 500 lb, 1000 lb, 2000 lb, 5000 lb, Red (+) excitation
10000 lb, 25000 lb, 50000 lb, 100000 lb Black (-) excitation
Non-linearity 300 lb to 2K lb ±0.02 % of rated output Green (+) output
Non-linearity White (-) output
±0.04 % of rated output
5K lb to 100K lb
Hysteresis ±0.02 % of rated output
TYPICAL SYSTEM DIAGRAM
Non-repeatability ±0.01 % of rated output
Static error band
In-Line Amplifiers Customer Supplied
±0.02 % of rated output (Used with unamplified units only) Chart Recorder
300 lb to 2K lb
Alarm Panel
Static error band Amplifier Output
±0.03 % of rated output Universal In-Line Amplifiers Data Acquisition
5K lb to 10K lb Computer
UV +/-5 VDC
Static error band UV-10 +/-10 VDC PLC
±0.04 % of rated output UBP 0 +/-5 VDC
25K lb to 100K lb
U3W 4-20mA (3 wire)
Output @ rated capacity 4 mV/V (nominal) U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Operation Tension/compression DV-05 0 +/- 5 VDC (3 wire) Power Supply
Resolution Infinite DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)
Standard calibration Tension (+) and compression (-)
Honeywell
In-Line Amplifier
ENVIRONMENTAL SPECIFICATIONS Output
Serial Number
Input

Characteristic Measure
Display Units
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
Temperature, compensated -9 °C to 46 °C [15 °F to 115 °F] SC500 SC1000 SC2000
SC2001 SC3004
Temperature effect, zero ±0.008 % of rated output/°F GM NK HH
Temperature effect, output ±0.008 % of reading/°F MODEL 3143P 7541 7558 7561-PSD

ELECTRICAL SPECIFICATIONS OR
2003.1 lb.
Characteristic Measure VALUE
L1 L2 L3 L4
CLEAR CHAN TARE

Strain gage type Foil


UP DOWN SETUP ENTER EXIT

Excitation (maximum) 10 Vdc or Vac RMS


Insulation resistance > 5000 mOhm @ 50 Vdc Mating Connectors & Cables

Input resistance (tolerance) 350 ohm +40/-3.5 ohm 023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable
Output resistance 350 ohm ±3.5 ohm (unamplified unit with sense leads but not shunt cal)
(tolerance) 7205-75-XX** Mating connector & 4 conductor cable
Sensitivity 300 lb to 2K lb 2 mV/V of rated output (unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
Sensitivity 5K lb to 100K lb 4 mV/V of rated output (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
Zero balance (tolerance) ±1.0 %
(for connection to instrument 7541)

* XX represents length in feet 100ft maximum


MECHANICAL SPECIFICATIONS ** XX represents length in feet 20ft maximum
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material See table on next page
Creep ±0.03 %
Off-centered load sensitivity ±0.10 %
Side load sensitivity ±0.10 %

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

MECHANICAL CHARACTERISTICS
Nominal load limit
capacity Fz
Model lb N Static overload Weight (lb) Weight with base Flexure
capacity (% of (lb) material
nominal capacity)
3143-P 300 1K 150 1.0 2.5 Aluminum
3143-P 500 2K 150 1.0 2.5 Aluminum
3143-P 1K 5K 150 1.0 2.5 Aluminum
3143-P 2K 10K 150 1.0 2.5 Aluminum
3144-P 5K 22K 150 2.9 6.5 Steel
3144-P 10K 45K 150 2.9 6.5 Steel
3145-P 25K 110K 150 9.1 21.5 Steel
3145-P 50K 200K 150 9.1 21.5 Steel
3146-P 100K 500K 150 23.5 52.5 Steel

TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM


In-Line Amplifiers Customer Supplied In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder (Used with unamplified units only) Chart Recorder
Alarm Panel Alarm Panel
Amplifier Output Amplifier Output
Universal In-Line Amplifiers Data Acquisition Data Acquisition
Universal In-Line Amplifiers
UV +/-5 VDC Computer UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC UBP 0 +/-5 VDC
U3W 4-20mA (3 wire) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire) U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire) DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire) DV10 0 +/- 10 VDC (3 wire)

Honeywell Honeywell
In-Line Amplifier In-Line Amplifier
Output Input Output Input
Serial Number Serial Number

Display Units Display Units

SC500 SC1000 SC2000 SC500 SC1000 SC2000


SC2001 SC3004 SC2001 SC3004
GM NK HH GM NK HH
7541 7558 7561-PSD 7541 7558 7561-PSD

MODEL 3144P MODEL 3145P


2003.1 lb. 2003.1 lb.
OR L1 L2 L3 L4 OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE VALUE CLEAR CHAN TARE

UP DOWN SETUP ENTER EXIT UP DOWN SETUP ENTER EXIT

Mating Connectors & Cables Mating Connectors & Cables

023-LW181-023-LF Mating Connector 023-LW181-023-LF Mating Connector


7205-76-XX* Mating connector & 6 conductor cable 7205-76-XX* Mating connector & 6 conductor cable
(unamplified unit with sense leads but not shunt cal) (unamplified unit with sense leads but not shunt cal)
7205-75-XX** Mating connector & 4 conductor cable 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal) (unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable 7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541) (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable 7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541) (for connection to instrument 7541)

* XX represents length in feet 100ft maximum * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum ** XX represents length in feet 20ft maximum

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3140-P
MOUNTING DIMENSIONS
Model Capac- Ø A in Ø B in C in D in E F in G in ØH J in K L in
ity (lb) Thread Thread
3143-P-300 300 4.12 1.29 0.13 2.50 1/2-20 1.12 1.25 1.25 0.03 1/2-20 0.88
UNF 3B UNF 3B
3143-P-500 500 4.12 1.29 0.13 2.50 1/2-20 1.12 1.25 1.25 0.03 1/2-20 0.88
UNF 3B UNF 3B
3143-P-1K 1000 4.12 1.29 0.13 2.50 1/2-20 1.12 1.25 1.25 0.03 1/2-20 0.88
UNF 3B UNF 3B
3143-P-2K 2000 4.12 1.29 0.13 2.50 1/2-20 1.12 1.25 1.25 0.03 1/2-20 0.88
UNF 3B UNF 3B
3144-P-5K 5000 4.12 1.29 0.13 2.50 5/8-18 1.12 1.25 1.25 0.03 5/8-18 0.88
UNF 3B UNF 3B
3144-P-10K 10000 4.12 1.29 0.13 2.50 5/8-18 1.12 1.25 1.25 0.03 5/8-18 0.88
UNF 3B UNF 3B
3145-P-25K 25000 6.06 2.34 0.13 3.50 1¼-12 1.50 1.63 1.25 0.03 1¼-12 1.50
UNF 3B UNF 3B
3145-P-50K 50000 6.06 2.58 0.13 3.50 1¼-12 1.50 1.63 2.25 0.03 1¼-12 1.50
UNF 3B UNF 3B
3146-P- 100000 8.00 3.76 0.25 4.50 1¾-12 2.25 2.25 3.00 0.03 1¾-12 1.75
100K UNF 3B UNF 3B

PT02E-10-6P CONNECTOR

ØB ØH
ØA

C
E THD. K THD.
F DEEP G L DEEP

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3140-P Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
TYPICAL SYSTEM DIAGRAM order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder Honeywell during the period of coverage, Honeywell will repair
Alarm Panel or replace, at its option, without charge those items it finds
Amplifier Output
Universal In-Line Amplifiers Data Acquisition defective. The foregoing is buyer’s sole remedy and is in lieu
UV +/-5 VDC Computer
of all warranties, expressed or implied, including those of
UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC merchantability and fitness for a particular purpose. In no
U3W 4-20mA (3 wire)
4-20mA (2 wire)
event shall Honeywell be liable for consequential, special, or
U2W
DIN rail Mount In-Line Amplifiers indirect damages.
DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire) While we provide application assistance personally, through our
DV10 0 +/- 10 VDC (3 wire)
literature and the Honeywell web site, it is up to the customer to
Honeywell determine the suitability of the product in the application.
In-Line Amplifier

Specifications may change without notice. The information we


Output Input
Serial Number

supply is believed to be accurate and reliable as of this printing.


Display Units
However, we assume no responsibility for its use.
SC500 SC1000 SC2000
SC2001 SC3004 For more information about Sensing and Control products, visit
GM NK HH www.honeywell.com/sensing or call +1-815-235-6847
7541 7558 7561-PSD
Email inquiries to info.sc@honeywell.com
MODEL 3146P
2003.1 lb.
WARNING
OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE
PERSONAL INJURY
UP DOWN SETUP ENTER EXIT

• DO NOT USE these products as safety or emergency


stop devices or in any other application where failure of
Mating Connectors & Cables the product could result in personal injury.
023-LW181-023-LF Mating Connector Failure to comply with these instructions could result in
7205-76-XX* Mating connector & 6 conductor cable
(unamplified unit with sense leads but not shunt cal)
death or serious injury.
7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable WARNING
(for connection to instrument 7541) MISUSE OF DOCUMENTATION
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541) • The information presented in this catalogue is for
* XX represents length in feet 100ft maximum
reference only. DO NOT USE this document as product
** XX represents length in feet 20ft maximum installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008625-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3167
Tension/Compression Pancake Load Cell
DESCRIPTION
These general purpose designs have exceptional structural Minimum deflection and compactness make these general-
capability to withstand extraneous loads, such as torque, purpose load cells easy to install and use.
bending moments, and side loads.

Available in capacities of 25 lb to 300 lb, they offer maximum


performance and enhanced accuracy.

FEATURES
• Up to 0.05 % accuracy
• 25 lb to 300 lb range
• Integral cable (standard)
• Low sensitivity to extraneous loads
• Low deflection
• Built-in temperature compensation

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3167

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure
In-Line Amplifiers Customer Supplied
Load range 1
25, 50, 100, 200, 300 lb (Used with unamplified units only) Chart Recorder
Non-linearity ±0.05 % of rated output Alarm Panel
Amplifier Output
Hysteresis ±0.05 % of rated output Universal In-Line Amplifiers Data Acquisition
UV +/-5 VDC Computer
Repeatability ±0.02 % of rated output UV-10 +/-10 VDC PLC
Output @ rated capacity 2 mV/V ±0.25 % (nominal) UBP 0 +/-5 VDC
U3W 4-20mA (3 wire)
Operation Tension/compression U2W 4-20mA (2 wire)
Resolution Infinite DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
Standard calibration Tension (+) and compression (-) DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)

ENVIRONMENTAL SPECIFICATIONS Honeywell


In-Line Amplifier
Characteristic Measure Output
Serial Number
Input

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]


Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] Display Units
Temperature effect, zero ±0.002 % of rated output/°F SC500 SC1000 SC2000
Temperature effect, output ±0.002 % of reading/°F SC2001 SC3004
GM NK HH
7541 7558 7561-PSD
ELECTRICAL SPECIFICATIONS MODEL 3167
Characteristic Measure
2003.1 lb.
Strain gage type Foil OR L1 L2 L3 L4

Excitation (maximum) 20 Vdc or Vac RMS VALUE


UP
CLEAR
DOWN SETUP
CHAN
ENTER
TARE
EXIT

Insulation resistance > 5000 mOhm @ 50 Vdc


Bridge resistance 350 ohm
(tolerance)
Number of bridges 1
Zero balance ±5.0 %
Electrical termination 15 ft of Belden 8723 four-conductor
shielded cable

MECHANICAL SPECIFICATIONS
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Natural frequency See table

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static over- Shear FX or Bending MX Torque MZ Deflection at Ringing fre-
load capacity FY (lb) or MY (lb-in) (lb-in) nominal load quency (Hz)
(% of nominal limit (in)
capacity)
25 125 150 150 150 40 0.003 2100
50 200 150 150 150 40 0.003 2800
100 500 150 250 180 40 0.003 3800
200 1K 150 250 180 40 0.003 5400
300 1.5K 150 250 180 40 0.003 7000

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in]
3167 5,72 [2.25] - [1/4-28] 0,95 [0.38] 1,10 [0.44] 1,10 [0.44]

F cm [in] G cm [in] G cm [in] J cm [in] K cm [in]


0,24 [0.09] 3,80 [1.50] 0,16 [0.06] 4,44 [1.75] 6,98 [2.75]

B UNF THD.
C DEEP BOTH ENDS

A +/- H

FOUR COND. SHIELD CABLE


BELDEN 8723
15 FEET

E
F

D G

J DIA. H

K DIA.

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3167 Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008622-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3173
Tension/Compression Pancake Load Cell
DESCRIPTION
The Model 3173 covers the lower capacity ranges of 200 load cells are well suited to materials testing machines and other
pounds force to 3000 pounds force, while exhibiting the high applications requiring a rugged load sensor. Often ideal for high
performance characteristics of stiffness and accuracy. These cycle count applications.

FEATURES
• English threads
• Enhanced accuracy, 0.07 %
• Low deflection
• Fatigue-resistant design and enhanced performance
• Low full-scale capacity
• Low profile
• Decreased sensitivity to extraneous loading

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3173

PERFORMANCE SPECIFICATIONS WIRING CODES


Characteristic Measure Cable
Load range 1
200, 500, 1K, 2K, 3K lb Red (+) excitation
Accuracy 0.07 % Black (-) excitation
Non-linearity ±0.05 % of rated output Green (+) output
Hysteresis ±0.05 % of rated output White (-) output
Repeatability ±0.02 % of rated output
Output @ rated capacity
TYPICAL SYSTEM DIAGRAM
1.50 mV/V (nominal)
(200 lb to 1K lb)
In-Line Amplifiers Customer Supplied
Output @ rated capacity (Used with unamplified units only) Chart Recorder
2.00 mV/V (nominal)
(2K lb to 3K lb) Alarm Panel
Amplifier Output
Data Acquisition
Operation Tension/compression Universal In-Line Amplifiers
UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC
Resolution Infinite UBP 0 +/-5 VDC
U3W 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)

ENVIRONMENTAL SPECIFICATIONS
Honeywell
Characteristic Measure In-Line Amplifier
Output
Serial Number
Input

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]


Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Recommended Tension Base
Temperature effect, zero ±0.002 % of rated output/°F SC500 SC1000 SC2000
064-LW31684-1 SC2001 SC3004
Temperature effect, output ±0.002 % of reading/°F GM NK HH
7541 7558 7561-PSD
MODEL 3173
ELECTRICAL SPECIFICATIONS
2003.1 lb.
Characteristic Measure OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE

Strain gage type Foil UP DOWN SETUP ENTER EXIT

Excitation (maximum) 20 Vdc or Vac RMS


Mating Connectors & Cables
Insulation resistance > 5000 mOhm @ 50 Vdc
023-LW181-023-LF Mating Connector
Input resistance 700 ohm
7205-76-XX* Mating connector & 6 conductor cable
Output resistance 700 ohm (unamplified unit with sense leads but not shunt cal)
7205-75-XX** Mating connector & 4 conductor cable
Zero balance ±1.0 % (unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
Electrical termination PT02E-10-6P (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)

MECHANICAL SPECIFICATIONS * XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Fatigue life (0 to full fatigue 100 x 106 cycles
load)
Fatigue life (full fatigue ten- 50 x 106 cycles
sion to compression)
Natural frequency See table

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static overload Shear FX or FY Bending MX or Torque MZ Deflection at Ringing fre-
capacity (% of (lb) MY (lb-in) (lb-in) nominal load quency (Hz)
nominal capac- limit (in)
ity)
200 1K 150 100 4471 185 0.003 1500
500 2K 150 100 15625 466 0.003 2440
1K 5K 150 100 15500 911 0.003 3900
2K 10K 150 100 4000 2133 0.001 5500
3K 15K 150 100 5166 2818 0.001 7200

MOUNTING DIMENSIONS
G threads

M cm [in]
screws K

O cm [in]

Q cm [in]
A cm [in]

B cm [in]

C cm [in]

D cm [in]

H cm [in]

N cm [in]
E cm [in]

P cm [in]
Capacity

F cm [in]

L cm [in]
I cm [in]
English

holes J

Bolting
Model

No. of
N [lb]

3173 10,47 7,24 3,23 3,48 0,31 0,15 8.89 0,71 8 3,18 1,27 0,08 2,87 2,21 0,64
900-13.5K
[200-3K]

5/8-18 UNF-3B

1/4-28 hexhead*
[4.12] [2.85] [1.27] [1.37] [0.12] [0.06] [3.5] [0.28] [1.25] [0.50] [0.03] [1.13] [0.87] [0.25]

* tighten to 200 in-lbs

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3173 Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008618-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 3174-3176
Model 3174

Tension/Compression Pancake Load Cell Model 3174 with


tension base

DESCRIPTION
Models 3174, 3175, and 3176 are fatigue-resistant, low-profile These load cells are extremely resistant to extraneous bending
tension and compression load cells that are well suited to and side-loading forces. The structure virtually eliminates
materials testing machines and other applications requiring bending strains at the strain gage, minimizing the primary cause
a rugged load sensor, while exhibiting the high performance of load cell failures.
characteristics of stiffness and accuracy.

FEATURES
• English threads
• Enhanced accuracy, up to 0.07 %
• Low deflection
• Fatigue-resistant design and enhanced performance
• Tension/compression capacity
• Low profile
• Low sensitivity to extraneous loading

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3174-3176

PERFORMANCE SPECIFICATIONS WIRING CODES


Characteristic Measure Cable
Load range 1
5K, 10K, 20K, 50K, 100K lb Red (+) excitation
Non-linearity ±0.05 % of rated output Black (-) excitation
Hysteresis ±0.05 % of rated output Green (+) output
Repeatability ±0.02 % of rated output White (-) output
Output @ rated capacity 2.00 mV/V (nominal)
Creep ±0.025 % of rated output TYPICAL SYSTEM DIAGRAM
Resolution Infinite In-Line Amplifiers Customer Supplied
Standard calibration Tension (+) and compression (-) (Used with unamplified units only) Chart Recorder
Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Computer
ENVIRONMENTAL SPECIFICATIONS UV ±5 Vdc
PLC
UV-10 ±10 Vdc
Characteristic Measure UBP 0 ±5 Vdc
U3W 4-20mA (3 wire)
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] DV-05 0 ±5 Vdc (3 wire) Power Supply
DA-05 4-20mA (3 wire)
Temperature effect, zero ±0.002 % of rated output/°F DV10 0 ±10 Vdc (3 wire)
Temperature effect, output ±0.002 % of reading/°F
Honeywell
In-Line Amplifier
Output Input

ELECTRICAL SPECIFICATIONS
Serial Number

Characteristic Measure Display Units


Recommended Tension Base
Strain gage type Foil SC500 SC1000 SC2000
064-LW30774-1 SC2001 SC3004
Excitation (maximum) 20 Vdc or Vac RMS GM NK HH
7541 7558 7561-PSD
Insulation resistance > 5000 mOhm @ 50 Vdc
MODEL 3174
Bridge resistance 700 ohm
Number of bridges 1 2003.1 lb.
OR L1 L2 L3 L4
Zero balance ±1.0 % VALUE
UP
CLEAR
DOWN SETUP
CHAN
ENTER
TARE
EXIT

Electrical termination PT02E-10-6P


Mating Connectors & Cables

MECHANICAL SPECIFICATIONS 023-LW181-023-LF Mating Connector


7205-76-XX* Mating connector & 6 conductor cable
Characteristic Measure (unamplified unit with sense leads but not shunt cal)
7205-75-XX** Mating connector & 4 conductor cable
Static overload capacity 150 % of nominal capacity (unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
Material Carbon steel (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
Fatigue life (0 to full fatigue 100 x 106 cycles
(for connection to instrument 7541)
load)
* XX represents length in feet 100ft maximum
Fatigue life (full fatigue ten- 50 x 106 cycles ** XX represents length in feet 20ft maximum
sion to compression)
Natural frequency See table

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
Model lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
3174 5K 20K 150 100 11K 9K 12K 0.001 6500
3174 10K 50K 150 100 25K 27K 24K 0.001 7200
3174 20K 100K 150 100 55K 58K 35K 0.001 8600
3175 50K 200K 150 100 32K 33K 67K 0.001 12000
3176 100K 500K 150 100 78K 147K 196K 0.001 15000

TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM


In-Line Amplifiers Customer Supplied In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder (Used with unamplified units only) Chart Recorder
Alarm Panel Alarm Panel
Amplifier Output Amplifier Output
Universal In-Line Amplifiers Data Acquisition Data Acquisition
Computer Universal In-Line Amplifiers
UV ±5 Vdc UV ±5 Vdc Computer
UV-10 ±10 Vdc PLC PLC
UV-10 ±10 Vdc
UBP 0 ±5 Vdc
UBP 0 ±5 Vdc
U3W 4-20mA (3 wire)
U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
DV-05 0 ±5 Vdc (3 wire) Power Supply DIN rail Mount In-Line Amplifiers
DV-05 0 ±5 Vdc (3 wire) Power Supply
DA-05 4-20mA (3 wire)
DV10 0 ±10 Vdc (3 wire) DA-05 4-20mA (3 wire)
DV10 0 ±10 Vdc (3 wire)

Honeywell
In-Line Amplifier Honeywell
Output
Serial Number
Input
In-Line Amplifier
Output Input
Serial Number

Display Units
Display Units
Recommended Tension Base
SC500 SC1000 SC2000 Recommended Tension Base
SC2001 SC3004 SC500 SC1000 SC2000
064-LW31496-1
GM NK HH 064-LW31496-2 SC2001 SC3004
7541 7558 7561-PSD GM NK HH
MODEL 3175 7541 7558 7561-PSD
MODEL 3176

2003.1 lb.
OR L1 L2 L3 L4
2003.1 lb.
VALUE CLEAR CHAN TARE OR L1 L2 L3 L4
UP DOWN SETUP ENTER EXIT
VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

Mating Connectors & Cables


Mating Connectors & Cables
023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable 023-LW181-023-LF Mating Connector
(unamplified unit with sense leads but not shunt cal) 7205-76-XX* Mating connector & 6 conductor cable
7205-75-XX** Mating connector & 4 conductor cable (unamplified unit with sense leads but not shunt cal)
(unamplified unit without sense leads but not shunt cal) 7205-75-XX** Mating connector & 4 conductor cable
7205-83-XX* Mating connector & 6 conductor cable (unamplified unit without sense leads but not shunt cal)
(for connection to instrument 7541) 7205-83-XX* Mating connector & 6 conductor cable
7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)
(for connection to instrument 7541) 7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3174-3176
MOUNTING DIMENSIONS
Model Ca- A cm B cm C cm D cm E cm F cm G cm H cm Tap thru I J cm K cm No. Bolting M English
pacity [in] [in] [in] [in] [in] [in] [in] [in] English [in] [in] of
N [lb] holes
L
3174 20K- 15,39 10,99 6,35 4,45 0,310 0,13 5,72 2,06 1¼-12 13,02 10,3 12 3/8-24 hex head, 2¼
100K [6.06] [4.33] [2.42] [1.75] [0.12] [0.05] [2.25] [0.81] UNF-3B [5.13] [13/32] inches long, tighten to
[5K- 750 in-lb
20K]
3175 200K 20,32 13,15 7,98 6,35 0,30 0,08 7,98 n/a 1¾-12 16,51 13,50 16 ½-20 hex head, 3 3/8 in
[50K] [8.00] [5.18] [3.14] [2.50] [0.12] [0.03] [3.14] UN-3B [6.50] [17/32] long, tighten to 120 ft-lb,
grade 8 bolts
3176 500K 27,94 18,02 12,50 8,89 0,30 0,08 12,50 n/a 2¾-8 UN- 22,86 16,70 16 5/8-18 hex head, 4 5/8
[100K] [11.00] [7.09] [4.92] [3.50] [0.12] [0.03] [4.92] 3B [9.00] [21/32] in long, tighten to 290
ft-lb, grade 8 bolts

* tighten to 200 in-lbs

RECEP.
PT02E-10-6P (MATING
CONNECTOR FURNISHED)

J BOLT CIRCLE THIS SURFACE FLAT TO


0.0005 INCH TIR AND
FINISH TO 64 MAX

16
45
MODEL
3174
ONLY

2.25 INCH
A G
5.12 CM

K DIA. THRU
I TAP THRU L NUMBER OF HOLES
EQUALLY SPACED M RECOMMENDED
BOLTING SCREWS
C DIA. I TAP THRU
H
E F
D

Tension bases are recommended for all model 3174, 3175 and 3176 applications.
D When mounting without the tension base, attention must be given to the mating
surface with regard to flatness, hardness and stiffness.

F B DIA.
A DIA.

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3174-3176 Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008619-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3397
Tension/Compression Pancake Load Cell
DESCRIPTION
These general purpose designs have exceptional structural Minimum deflection and compactness make these general-
capability to withstand extraneous loads, such as torque, purpose load cells easy to install and use.
bending moments, and side loads.

Available in capacities of 25 lb to 300 lb, they offer maximum


performance and enhanced accuracy.

FEATURES
• Up to 0.05 % accuracy
• 25 lb to 300 lb range
• Low sensitivity to extraneous loads
• Low deflection
• Built-in temperature compensation

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3397

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure
In-Line Amplifiers Customer Supplied
Load range 1
25, 50, 100, 200, 300 lb (Used with unamplified units only) Chart Recorder
Non-linearity ±0.05 % of rated output Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.05 % of rated output UV +/-5 VDC Computer
Repeatability ±0.02 % of rated output UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Output @ rated capacity 2 mV/V ±0.25 % (nominal) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Operation Tension/compression DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
Resolution Infinite DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) DV10 0 +/- 10 VDC (3 wire)

Honeywell
In-Line Amplifier
ENVIRONMENTAL SPECIFICATIONS Output
Serial Number
Input

Characteristic Measure
Display Units
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
SC500 SC1000 SC2000
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
SC2001 SC3004
Temperature effect, zero ±0.002 % of rated output/°F GM NK HH
7541 7558 7561-PSD
Temperature effect, output ±0.002 % of reading/°F MODEL 3397

ELECTRICAL SPECIFICATIONS OR
2003.1 lb.
L1 L2 L3 L4

Characteristic Measure VALUE


UP
CLEAR
DOWN SETUP
CHAN
ENTER
TARE
EXIT

Strain gage type Foil


Excitation (maximum) 20 Vdc or Vac RMS Mating Connectors & Cables
Insulation resistance > 5000 mOhm @ 50 Vdc 023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable
Bridge resistance 350 ohm
(unamplified unit with sense leads but not shunt cal)
(tolerance) 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
Number of bridges 1 or 2
7205-83-XX* Mating connector & 6 conductor cable
Zero balance ±5.0 % (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
Electrical termination PT02E-10-6P mates with PT06W-10-6S (for connection to instrument 7541)

* XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum
MECHANICAL SPECIFICATIONS
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Natural frequency See table

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Pancake Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static over- Shear FX or Bending MX Torque MZ Deflection at Ringing fre-
load capacity FY (lb) or MY (lb-in) (lb-in) nominal load quency (Hz)
(% of nominal limit (in)
capacity)
25 125 150 150 150 40 0.003 2100
50 200 150 150 150 40 0.003 2800
100 500 150 250 180 40 0.003 3800
200 1K 150 250 180 40 0.003 5400
300 1.5K 150 250 180 40 0.003 7000

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]
3397 6,98 [2.75] 0,55 [0.22] 0,32 [0.13] 4,44 [1.75] 5,60 [2.22] - [1/4-28]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in] N cm [in] P cm [in]


1,27 [0.50] 1,10 [0.44] 0,24 [0.09] 3,80 [1.50] 0,16 [0.06] 4,44 [1.75] 2,54 [1.00]

A
SPANNER WRENCH
HOLE B DIA.
F THD. C DEEP
G DEEP
BOTH ENDS

RECEP.
PTO2E-10-6P
E
DUAL BRIDGE
OPTIONAL

H DIA.
C J

P
K

L
N DIA.

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3397 Tension/Compression Pancake Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008623-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3127
Tension/Compression Canister Load Cell
DESCRIPTION
The Model 3127 fatigue-resistant load cells are extremely minimizing the primary cause of load cell failure. Dual bridge
resistant to extraneous bending and side loading forces. The option available for feedback control and redundancy.
structure virtually eliminates bending strains at the strain gage,

FEATURES
• Optional dual bridge not shown
• English threads (metric threads available: 3127-118)
• Resist fatigue failure
• Low failure rate
• Multi-beam structure design
• 10000000 N capacity
• Bending moment resistance of 7500000 lb inches
• 450000 lb of shear resistance

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3127

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder
Load range 1
10M N
Alarm Panel
Non-linearity ±0.2 % of rated output Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.2 % of rated output UV +/-5 VDC Computer
Repeatability ±0.05 % of rated output UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Output @ rated capacity ±2 mV/V (nominal) U3W 4-20mA (3 wire)
Operation Tension/compression U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Resolution Infinite DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) DV10 0 +/- 10 VDC (3 wire)

Honeywell
ENVIRONMENTAL SPECIFICATIONS In-Line Amplifier
Output Input

Characteristic Measure Serial Number

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]


Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero ±0.003 % of rated output/°F SC500 SC1000 SC2000
MODEL 3127 SC2001 SC3004
Temperature effect, output ±0.003 % of reading/°F GM NK HH
7541 7558 7561-PSD

ELECTRICAL SPECIFICATIONS
Characteristic Measure
2003.1 lb.
OR L1 L2 L3 L4
Strain gage type Foil
VALUE CLEAR CHAN TARE

Excitation (maximum) 20 Vdc or Vac RMS


UP DOWN SETUP ENTER EXIT

Insulation resistance > 5000 mOhm @ 50 Vdc


Bridge resistance 700 ohm Mating Connectors & Cables
(tolerance) 064-LW13621 Mating connector
Number of bridges 1 or 2 7200-76-XX* Mating connector and six conductor cable
(unamplified unit with sense leads but not shunt cal)
Zero balance ±1.0 %
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
Electrical termination MS-3102E-14S-5P (unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
MECHANICAL SPECIFICATIONS 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
Characteristic Measure
Static overload capacity 150 % of nominal capacity * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Material Carbon steel
Fatigue life (0 to full fatigue 100 x 106 cycles
load)
Fatigue life (full fatigue ten- 50 x 106 cycles
sion to compression)
Natural frequency See table

WIRING CODES
Wire
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Canister Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
2000K 10M 100 50 450K 7500K 1500K 0.007 1900

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in] J cm [in]
3127 57,15 20,32 [8.0] 16,51 [6.50] 6,35 [2.50] 44,78 43,18 [17] 28,58 16,51 [6.50] 24,77 [9.75]
[22.50] [17.63] [11.25]

K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] Q cm [in] R cm [in] S cm [in] *T cm [in] *U cm [in]
7,62 [3] 30,48 [12] 3,81 [1.50] 6,35 [2.50] 8,89 [3.50] 20,96 [8.25] 1,03 [0.41] 1,27 [0.50] M150-4 M42-3
[6-8] [1.75-12]

* 3127-118 • T and U are metric thread measures


* 3127 standard • T and U are English thread measures

H DIA. 3/4-10 THD.


K DIA. BOTH ENDS M DEEP 2 HOLES
RECEP. AT 180 LIFTING
N
MS-3102E-14S-5P

J C
G

B A

U THD. P DEEP, 12 HOLES


EQUALLY SPACED ON L DIA.
BOTH ENDS
T THD. D
Q DEEP SPANNER WRENCH HOLES F DIA.
BOTH ENDS R DIA. S DEEP 6 HOLES BOTH ENDS
EQUALLY SPACED BOTH ENDS E

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3127 Tension/Compression Canister Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008646-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3129-121
Tension/Compression Canister Load Cell
DESCRIPTION
The Model 3129-121 fatigue-resistant load cells are extremely minimizing the primary cause of load cell failure. Dual bridge
resistant to extraneous bending and side loading forces. The option available for feedback control and redundancy.
structure virtually eliminates bending strains at the strain gage,

FEATURES
• Optional dual bridge (not shown)
• Metric threads (English threads availble: 3129-112)
• Resist fatigue failure
• Multi-beam structure design
• 1500000 N capacity
• Bending moment resistance of 840000 lb inches
• 65000 lb of shear resistance

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3129-121

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure
In-Line Amplifiers Customer Supplied
Load range 1
750000, 1000000, 1500000 N (Used with unamplified units only) Chart Recorder
Non-linearity ±0.2 % of rated output Alarm Panel
Amplifier Output
Hysteresis ±0.2 % of rated output Universal In-Line Amplifiers Data Acquisition
UV +/-5 VDC Computer
Repeatability ±0.05 % of rated output UV-10 +/-10 VDC PLC
Output @ rated capacity ±2 mV/V (nominal) UBP 0 +/-5 VDC
U3W 4-20mA (3 wire)
Operation Tension/compression U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Resolution Infinite Power Supply
DV-05 0 +/- 5 VDC (3 wire)
Standard calibration Tension (+) and compression (-) DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)

ENVIRONMENTAL SPECIFICATIONS Honeywell


In-Line Amplifier
Characteristic Measure Output
Serial Number
Input

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]


Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] Display Units

Temperature effect, zero ±0.003 % of rated output/°F SC500 SC1000 SC2000


MODEL 3127 SC2001 SC3004
Temperature effect, output ±0.003 % of reading/°F GM NK HH
7541 7558 7561-PSD
ELECTRICAL SPECIFICATIONS
Characteristic Measure
2003.1 lb.
Strain gage type Foil OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE

Excitation (maximum) 20 Vdc or Vac RMS UP DOWN SETUP ENTER EXIT

Insulation resistance > 5000 mOhm @ 50 Vdc


Bridge resistance 350 ohm Mating Connectors & Cables
(tolerance)
064-LW13621 Mating connector
Number of bridges 1 or 2 7200-76-XX* Mating connector and six conductor cable
Zero balance ±1.0 % (unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
Electrical termination MS-3102E-14S-5P (unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
MECHANICAL SPECIFICATIONS 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
Characteristic Measure for connection to 7541
Static overload capacity 150 % of nominal capacity * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Material Carbon steel
Fatigue life (0 to full fatigue 100 x 106 cycles
load)
Fatigue life (full fatigue ten- 50 x 106 cycles
sion to compression)
Natural frequency See table

WIRING CODES
Wire
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Canister Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
150K 750K 150 75 40K 625K 150K 0.004 3000
200K 1M 150 75 55K 730K 260K 0.004 3400
300K 1.5M 150 75 65K 840K 236K 0.004 4100

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]
3129 25,4 [10] 17,78 [7] 3,81 [1.50] 10,8 [4.25] 19,05 [7.50] 12,70 [5]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in] *M cm [in] *N cm [in]


6,35 [2.50] 12,7 [5] 3,81 [1.50] 13,97 [5.50] 8,41 [3.31] M27-2 [1-8] M76-2 [3-12]

* 3129-121 • M and N are metric thread measures


* 3129-112 standard • M and N are English thread measures
E

J
N THD.
3.0 DEEP M THD. 1/2 DEEP
BOTH ENDS 8 HOLES EQUALLY SPACED
ON H DIA. D

C A

RECEP.
MS-3102E-14S-5P
SPANNER WRENCH HOLES
L DIA.
13/32 DIA. 3/8 DEEP
G 6 HOLES EQUALLY SPACED
B DIA. AT BOTH ENDS

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3129-121 Tension/Compression Canister Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008647-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3130-131
Tension/Compression Canister Load Cell
DESCRIPTION
The Model 3130-131 fatigue-resistant load cells are extremely minimizing the primary cause of load cell failure. Dual bridge
resistant to extraneous bending and side loading forces. The option available for feedback control and redundancy.
structure virtually eliminates bending strains at the strain gage,

FEATURES
• Optional dual bridge (not shown)
• Metric threads
• Resist fatigue failure
• Multi-beam structure design
• Capacities to 5000000 N
• Bending moment resistance up to 6110000 lb inches
• Up to 180000 lb of shear resistance
• Flexible mounting configurations

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3130-131

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure In-Line Amplifiers Customer Supplied
Load range 1
2M, 3.5M, 5M N (Used with unamplified units only) Chart Recorder
Non-linearity ±0.2 % of rated output Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.2 % of rated output Computer
UV +/-5 VDC
Repeatability ±0.05 % of rated output UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Output @ rated capacity ±2 mV/V (nominal) U3W 4-20mA (3 wire)
Operation Tension/compression U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Resolution Infinite DV-05 0 +/- 5 VDC (3 wire) Power Supply

Standard calibration Tension (+) and compression (-) DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)

ENVIRONMENTAL SPECIFICATIONS Honeywell


In-Line Amplifier

Characteristic Measure
Output Input
Serial Number

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]


Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero ±0.003 % of rated output/°F SC500 SC1000 SC2000
SC2001 SC3004
Temperature effect, output ±0.003 % of reading/°F GM NK HH
MODEL 3130 7541 7558 7561-PSD

ELECTRICAL SPECIFICATIONS
Characteristic Measure
2003.1 lb.
Strain gage type Foil OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE

Excitation (maximum) 20 Vdc or Vac RMS UP DOWN SETUP ENTER EXIT

Insulation resistance > 5000 mOhm @ 50 Vdc


Bridge resistance 700 ohm Mating Connectors & Cables
(tolerance)
064-LW13621 Mating connector
Number of bridges 1 or 2 7200-76-XX* Mating connector and six conductor cable
Zero balance ±1.0 % (unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
Electrical termination MS-3102E-14S-5P (unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
MECHANICAL SPECIFICATIONS 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
Characteristic Measure for connection to 7541

Static overload capacity 150 % of nominal capacity * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Material Carbon steel
Fatigue life (0 to full fatigue 100 x 106 cycles
load)
Fatigue life (full fatigue ten- 50 x 106 cycles
sion to compression)
Natural frequency See table

WIRING CODES
Wire
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Canister Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
500K 2M 150 50 94K 4530K 820K 0.006 2500
800K 3.5M 150 50 180K 5450K 1050K 0.006 3100
1000K 5M 150 50 180K 6110K 1100K 0.006 3600

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in]
3130 31,75 [12.50] 3,81 [1.50] 17,78 [7.0] 5,08 [2.0] 1,91 [0.75] 32,29 [12.75] 31,12 [12.25]

H cm [in] J cm [in] K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] *Q cm [in] *R cm [in]


15,88 [6.25] 13,34 [5.25] 2,54 [1.0] 19,86 [7.82] 6,35 [2.50] 24,15 [9.50] 8,89 [3.50] M42-3 [1.75-12] M125-4 [5-8]

* 3130-131 • Q and R are metric thread measures


* 3130 standard • Q and R are English thread measures
3/8 16 THD. 5/8 DEEP
J DIA. 2 HOLES AT 180 LIFTING
R THD. 1.0 BOTH ENDS E
P DEEP
BOTH ENDS
D

C A

L
Q THD. 2.0 DEEP
8 HOLES EQUALLY SPACED
ON N DIA. BOTH ENDS SPANNER WRENCH HOLES
G DIA. BOTH ENDS
RECEP. 13/32 DIA. 3/8 DEEP 4 HOLES
M F DIA. EQUALLY SPACED BOTH ENDS
MS-3102E-14S-5P

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3130-131 Tension/Compression Canister Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008644-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3156
Tension/Compression Canister Load Cell
DESCRIPTION
The Model 3156 fatigue-resistant load cells are extremely minimizing the primary cause of load cell failure. Dual bridge
resistant to extraneous bending and side loading forces. The option available for feedback control and redundancy.
structure virtually eliminates bending strains at the strain gage,

FEATURES
• English threads (metric configuration available: 3156-133)
• Resist fatigue failure
• Minimize bending strains
• Dual bridges available on all models
• Multi-beam structure design
• Enhanced resistance to side loads and bending moments

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3156

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder
Load range 1
100K, 200K, 500K, 750K N
Alarm Panel
Non-linearity ±0.2 % of rated output Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.2 % of rated output UV +/-5 VDC Computer
Repeatability ±0.05 % of rated output UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Output @ rated capacity ±2 mV/V (nominal) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Operation Tension/compression DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
Resolution Infinite
DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) DV10 0 +/- 10 VDC (3 wire)

Honeywell
ENVIRONMENTAL SPECIFICATIONS In-Line Amplifier
Output Input
Serial Number

Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
SC500 SC1000 SC2000
Temperature effect, zero ±0.003 % of rated output/°F SC2001 SC3004
GM NK HH
Temperature effect, output ±0.003 % of reading/°F MODEL 3156 7541 7558 7561-PSD

ELECTRICAL SPECIFICATIONS
Characteristic Measure OR
2003.1 lb.
L1 L2 L3 L4
Strain gage type Foil VALUE
UP
CLEAR
DOWN SETUP
CHAN
ENTER
TARE
EXIT

Excitation (maximum) 30 Vdc or Vac RMS


Insulation resistance > 5000 mOhm @ 50 Vdc
Mating Connectors & Cables
Bridge resistance 350 ohm
064-LW13621 Mating connector
(tolerance)
7200-76-XX* Mating connector and six conductor cable
Number of bridges 1 or 2 (unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
Zero balance ±1.0 %
(unamplified sensor without sense leads)
Electrical termination MS-3102E-14S-5P 7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
MECHANICAL SPECIFICATIONS for connection to 7541
Characteristic Measure * XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Fatigue life (0 to full fatigue 100 x 106 cycles
load)
Fatigue life (full fatigue ten- 50 x 106 cycles
sion to compression)
Natural frequency See table

WIRING CODES
Wire
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Canister Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
25K 100K 150 100 2K 68K 10K 0.003 2100
50K 200K 150 100 6K 130K 20K 0.003 3000
100K 500K 150 100 10K 220K 85K 0.003 4200
150K 750K 150 100 20K 220K 85K 0.003 4800

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in]
3156 17,78 [7] 13,97 [5.50] 8,89 [3.50] 5,41 [2.13] 12,07 [4.75] 2,87 [1.13] 13,84 [5.45]

H cm [in] J cm [in] K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] *R cm [in]


9,12 [3.59] 8,89 [3.50] 0,79 [0.31] 0,95 [0.38] 5,08 [2] 3,18 [1.25] M20 x 2.5 [3/4-10] M52 x 2 [2-12]

* 3156-133 • P and R are metric thread measures


* 3156 standard • P and R are English thread measures
SPANNER WRENCH HOLES
H
L DIA. K DEEP
3 HOLES EQUALLY SPACED
BOTH ENDS
RECEP.
MS-3102E-14S-5P

R THD.
M DEEP
BOTH ENDS P THD. N DEEP 6 HOLES
EQUALLY SPACED ON J DIA.
BOTH ENDS

A
E

C
F

D
DIA.
B

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3156 Tension/Compression Canister Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008645-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RF
Rod End In-line Tension Load Cell
DESCRIPTION
Model RF, with female threads, is a high output rod end load cell The optional high output signal offers resistance to electrical
designed to be mounted inline to the load axis to measure ten- noise as well as additional signal resolution. Additional options
sion. The outputs for these load cells are ±5 Vdc or 10 Vdc, or include an internal buffered shunt calibration circuit for ease of
4 mA to 20 mA (two wire) all calibrated in tension. The mount- setup with an associated indicator, and a variety of thread selec-
ing thread configurations and the all welded stainless steel tions, including metric sizes.
construction make these tension load cells ideal for a variety of
rugged field applications as well as in the laboratory.

FEATURES
• 2000 lb to 200000 lb range
• Female/female threads
• Stainless steel, all-welded construction
• 0 Vdc to 5 Vdc or 4 mA to 20 mA outputs
• Up to 0.15 % linearity
• CE approved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RF
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
Characteristic Measure Characteristic Measure
Load ranges12 2000 lb to 200000 lb Maximum allowable load 150 % FS1
Linearity Weight See table
±0.2 % full scale
100 lb to 1000 lb
Material Stainless steel
Linearity
±0.15 % full scale Deflection full scale See table
2000 lb to 50000 lb
Natural frequency See table
Linearity
±0.2 % full scale
75000 lb to 20000 lb
Hysteresis RANGE CODES
±0.2 % full scale
100 lb to 1000 lb Range Available ranges Range Available ranges
Hysteresis Code Code
±0.15 % full scale
2000 lb to 50000 lb DL 2000 lb EL 20000 lb
Hysteresis DN 3000 lb EN 30000 lb
±0.2 % full scale
75000 lb to 20000 lb
DP 4000 lb EP 50000 lb
Non-repeatability ± 0.05 % full scale
DR 5000 lb ER 75000 lb
Output 2 mV/V
DT 75000 lb ET 100000 lb
Operation Tension
DV 10000 lb FJ 150000 lb
Resolution Infinite
EJ 15000 lb FL 200000 lb

ENVIRONMENTAL SPECIFICATIONS
WIRING CODES
Characteristic Measure
Connector Unamplified (Std.)
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
A (+) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
B (+) excitation
Temperature effect, zero 0.005 % full scale/°F
C (-) excitation
Temperature effect, span 0.005 % full scale/°F
D (-) excitation
E (-) output
ELECTRICAL SPECIFICATIONS
F (+) output
Characteristic Measure
Strain gage type Bonded foil DEFLECTIONS AND RINGING FREQUENCIES
Excitation (calibration) 10 Vdc
Capacity (lb) Deflection at Ringing fre- Weight kg
Excitation (acceptable) Up to 15 Vdc or Vac full scale mm quency (Hz) [lb]
Insulation resistance 5000 mOhm @ 50 Vdc [in]
Bridge resistance (toler- 350 ohm 2000 0,076 [0.003] 5000 0,58 [1.3]
ance) 3000 0,076 [0.003] 5000 0,58 [1.3]
Zero balance (tolerance) ±1% full scale 4000 0,076 [0.003] 5100 0,58 [1.3]
Shunt calibration data Included 5000 0,076 [0.003] 5200 0,58 [1.3]
Electrical termination (std) PTIH-10-6P or equivalent (hermetic 7500 0,076 [0.003] 8000 0,72 [1.6]
2000 lb to 50000 lb stainless)
10000 0,076 [0.003] 8500 0,72 [1.6]
Electrical termination (std) MS3102E-14S-6P or equivalent
15000 0,076 [0.003] 9000 0,72 [1.6]
75000 lb to 200000 lb
20000 0,102 [0.004] 9000 0,77 [1.7]
Mating connector (not in- PT06A-10-6S or equivalent (AA111)
cluded) 2000 lb to 50000 lb 30000 0,102 [0.004] 8000 1,58 [3.5]
Mating connector (not MS3106A-14S-6S or equivalent (AA121) 50000 0,127 [0.005] 8000 1,67 [3.7]
included) 75000 lb to 75000 to 0,152 [0.006] 3500 18,00 [39.7]
200000 lb 100000
150000 to 0,178 [0.007] 3000 33,02 [72.8]
200000

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier Intrinsically safe
Voltage output: Voltage output: Voltage output: Current three- Current two-
specifica- amp: Option 2n
Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tions (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to
(voltage) 32 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse Yes Yes Yes Yes Yes Yes
voltage
protection
Short cir. Momentary Momentary Momentary Yes Yes Yes
protection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector B Output common B Output common** B Output common** B Output common** B No connection B No connection
(std)5 C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable5,6,7 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RF
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F8
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F8
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F8
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2b. 4 wire, ±5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12
amplifiers 2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
2j. 4 mA to 20 mA (three-wire) output 2u. Unamplified, mV/V output
2k. 4 mA to 20 mA (two-wire)12
Internal amp 3a. Input/output isolation7
enhance- 3d. Remote buffered shunt calibration
ments
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) 6g. Integral cable: Neoprene
termination (ranges 50000 lb and below) 6h. Integral cable: Silicone
6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6), (max. 160 °F) (ranges above 50000 lb)6 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon 6q. Integral cable: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector on end of cable
Shunt 8a. Precision internal resistor8
calibration
Bridge type 11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Zero and 14a. No access to zero and span adjustment
span
adjustment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only Amplified only
Order code D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in]
(Unamp/Amp)
AL414/AL614 38,1 [1.50] 107,95 [4.25] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]
AL416/AL616 44,45 [1.75] 127 [5.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]
AL418/AL618 63,5 [2.50] 177,8 [7.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]

THREAD SIZES AND OPTION CODES


13a 13b 13c 13d 13e
Range (lb) 1/2-20 3/4-16 7/8-14 1-14 1 1/2-12
UNF UNF UNF UNF UNF
2000 to 5000 AL414 AL414 – – –
7500 to – AL416 AL416 AL416 AL418
15000
20000 – – AL416 AL416 AL418
30000 to – – – – AL418
50000
TYPICAL SYSTEM DIAGRAM
L2 mm [in] 19,05 24,13 24,13 25,4 38,1
[0.75] [0.95] [0.95] [1.0] [1.50]

NON-STANDARD RANGES - ORDER CODE AL412


Range (lb) Thread D mm [in] L1 mm L2 mm
type [in] [in]
75000 to 2 1/2-12 114,3 [4.50] 342,9 88,9 [3.50]
100000 UNF [13.50]
150000 to 3 1/2-8 UNF 139,7 [5.50] 457,2 114,3 [4.50]
200000 [18.00]

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RF Rod End In-Line Tension Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal ampli-
fier option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
7. Only available with option 2b or 2c. While we provide application assistance personally, through our
8. Not available with amplified option.
9. Consult factory for TEDS availability with amplified models. literature and the Honeywell web site, it is up to the customer to
10. Termination dependent; consult factory. determine the suitability of the product in the application.
11. This unit calibrated to Imperial (non-Metric) units.
12. 5000 ohm bridge required. Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more WARNING


Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this datasheet is for
sales offices, representatives reference only. DO NOT USE this document as product
and distributors. For application installation information.
• Complete installation, operation and maintenance
assistance, current specifica-
information is provided in the instructions supplied with
tions, pricing or name of the each product.
nearest Authorized Distributor,
Failure to comply with these instructions could result in
contact your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008656-2-EN IL50 GLO 
January 2010
www.honeywell.com Copyright © 2010 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RH
Rod End In-line Tension Load Cell
DESCRIPTION
Model RH, with male and female threads, is a high output rod The optional high output signal offers resistance to electrical
end load cell designed to be mounted inline to the load axis to noise as well as additional signal resolution. Additional options
measure tension. The outputs for these load cells are ±5 Vdc or include an internal buffered shunt calibration circuit for ease of
10 Vdc, or 4 mA to 20 mA (two wire) all calibrated in tension. The setup with an associated indicator, and a variety of thread selec-
mounting thread configurations and the all welded stainless steel tions, including metric sizes.
construction make these tension load cells ideal for a variety of
rugged field applications as well as in the laboratory.

FEATURES
• 2000 lb to 200000 lb range
• Male/female threads
• Stainless steel, all-welded construction
• 0 Vdc to 5 Vdc or 4 mA to 20 mA outputs
• Up to 0.15 % linearity
• CE approved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RH
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
Characteristic Measure Characteristic Measure
Load ranges12 2000 lb to 200000 lb Maximum allowable load 150 % FS1
Linearity Weight See table
±0.2 % full scale
100 lb to 1000 lb
Material Stainless steel
Linearity
±0.15 % full scale Deflection full scale See table
2000 lb to 50000 lb
Natural frequency See table
Linearity
±0.2 % full scale
75000 lb to 20000 lb
Hysteresis RANGE CODES
±0.2 % full scale
100 lb to 1000 lb Range Available ranges Range Available ranges
Hysteresis Code Code
±0.15 % full scale
2000 lb to 50000 lb DL 2000 lb EL 20000 lb
Hysteresis DN 3000 lb EN 30000 lb
±0.2 % full scale
75000 lb to 20000 lb
DP 4000 lb EP 50000 lb
Non-repeatability ± 0.05 % full scale
DR 5000 lb ER 75000 lb
Output 2 mV/V
DT 75000 lb ET 100000 lb
Operation Tension
DV 10000 lb FJ 150000 lb
Resolution Infinite
EJ 15000 lb FL 200000 lb

ENVIRONMENTAL SPECIFICATIONS
WIRING CODES
Characteristic Measure
Connector Unamplified (Std.)
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
A (+) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
B (+) excitation
Temperature effect, zero 0.005 % full scale/°F
C (-) excitation
Temperature effect, span 0.005 % full scale/°F
D (-) excitation
E (-) output
ELECTRICAL SPECIFICATIONS
F (+) output
Characteristic Measure
Strain gage type Bonded foil DEFLECTIONS AND RINGING FREQUENCIES
Excitation (calibration) 10 Vdc
Capacity (lb) Deflection at Ringing fre- Weight kg
Excitation (acceptable) Up to 15 Vdc or Vac full scale mm quency (Hz) [lb]
Insulation resistance 5000 mOhm @ 50 Vdc [in]
Bridge resistance (toler- 350 ohm 2000 0,076 [0.003] 5000 0,49 [1.1]
ance) 3000 0,076 [0.003] 5000 0,49 [1.1]
Zero balance (tolerance) ±1% full scale 4000 0,076 [0.003] 5100 0,49 [1.1]
Shunt calibration data Included 5000 0,076 [0.003] 5200 0,49 [1.1]
Electrical termination (std) PTIH-10-6P or equivalent (hermetic 7500 0,102 [0.004] 7500 0,81 [1.8]
2000 lb to 50000 lb stainless)
10000 0,102 [0.004] 7600 0,81 [1.8]
Electrical termination (std) MS3102E-14S-6P or equivalent
15000 0,127 [0.005] 8000 0,81 [1.8]
75000 lb to 200000 lb
20000 0,127 [0.005] 9800 0,81 [1.8]
Mating connector (not in- PT06A-10-6S or equivalent (AA111)
cluded) 2000 lb to 50000 lb 30000 0,127 [0.005] 8000 1,99 [4.4]
Mating connector (not MS3106A-14S-6S or equivalent (AA121) 50000 0,127 [0.005] 8200 1,99 [4.4]
included) 75000 lb to 75000 to 0,152 [0.006] 5000 16,01 [35.3]
200000 lb 100000
150000 to 0,178 [0.007] 4200 18,00 [39.7]
200000

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier Intrinsically safe
Voltage output: Voltage output: Voltage output: Current three- Current two-
specifica- amp: Option 2n
Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tions (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to
(voltage) 32 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse Yes Yes Yes Yes Yes Yes
voltage
protection
Short cir. Momentary Momentary Momentary Yes Yes Yes
protection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector B Output common B Output common** B Output common** B Output common** B No connection B No connection
(std)5 C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable5,6,7 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RH
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F8
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F8
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F8
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output 2k. 4 mA to 20 mA (two-wire)12
amplifiers 2b. 4 wire, ±5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12
2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
2j. 4 mA to 20 mA (three-wire) output
Internal amp 3a. Input/output isolation7
enhance- 3d. Remote buffered shunt calibration
ments
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) 6g. Integral cable: Neoprene
termination (ranges 50000 lb and below) 6h. Integral cable: Silicone
6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6), (max. 160 °F) (ranges above 50000 lb)6 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon 6q. Integral cable: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector on end of cable
Shunt 8a. Precision internal resistor8
calibration
Bridge type 11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Zero and 14a. No access to zero and span adjustment
span
adjustment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only Amplified only
Order code D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in]
(Unamp/Amp)
AL419/AL619 38,1 [1.50] 107,95 [4.25] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]
AL420/AL620 44,45 [1.75] 127 [5.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]
AL424/AL624 63,5 [2.50] 177,8 [7.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]

THREAD SIZES AND OPTION CODES


13a 13b 13c 13d 13e
Range (lb) 1/2-20 3/4-16 7/8-14 1-14 1 1/2-12
UNF UNF UNF UNF UNF
2000 to 5000 AL419/ AL419/ – – –
AL619 AL619
7500 to – AL420/ AL420/ AL420/ AL424/
15000 AL620 AL620 AL620 AL624
20000 – – AL420/ AL420/ AL424/
AL620 AL620 AL624
TYPICAL SYSTEM DIAGRAM
30000 to – – – – AL424/
50000 AL624
L2 mm [in] 19,05 24,13 24,13 25,4 38,1
[0.75] [0.95] [0.95] [1.0] [1.50]

NON-STANDARD RANGES - ORDER CODE AL425


Range (lb) Thread D mm [in] L1 mm L2 mm
type [in] [in]
75000 to 2 1/2-12 114,3 [4.50] 342,9 88,9 [3.50]
100000 UNF [13.50]
150000 to 3 1/2-8 UNF 139,7 [5.50] 457,2 114,3 [4.50]
200000 [18.00]

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RH Rod End In-Line Tension Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal ampli-
fier option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
7. Only available with option 2b or 2c. While we provide application assistance personally, through our
8. Not available with amplified option.
9. Consult factory for TEDS availability with amplified models. literature and the Honeywell web site, it is up to the customer to
10. Range dependent; consult factory. Termination dependent; consult determine the suitability of the product in the application.
factory.
11. Internal amp and termination dependent; consult factory. Specifications may change without notice. The information we
12. This unit calibrated to Imperial (non-Metric) units.
13. 5000 ohm bridge required. supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more WARNING


Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this datasheet is for
sales offices, representatives reference only. DO NOT USE this document as product
and distributors. For application installation information.
• Complete installation, operation and maintenance
assistance, current specifica-
information is provided in the instructions supplied with
tions, pricing or name of the each product.
nearest Authorized Distributor,
Failure to comply with these instructions could result in
contact your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008655-2-EN IL50 GLO 
January 2010
www.honeywell.com Copyright © 2010 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RM
Rod End In-line Tension Load Cell
DESCRIPTION
Model RM, with male threads, is a high output rod end load cell The optional high output signal offers resistance to electrical
designed to be mounted inline to the load axis to measure ten- noise as well as additional signal resolution. Additional options
sion. The outputs for these load cells are ±5 Vdc or 10 Vdc, or include an internal buffered shunt calibration circuit for ease of
4 mA to 20 mA (two wire) all calibrated in tension. The mount- setup with an associated indicator, and a variety of thread selec-
ing thread configurations and the all welded stainless steel tions, including metric sizes.
construction make these tension load cells ideal for a variety of
rugged field applications as well as in the laboratory.

FEATURES
• 2000 lb to 200000 lb range
• Male/male threads
• Stainless steel, all-welded construction
• 0 Vdc to 5 Vdc or 4 mA to 20 mA outputs
• Up to 0.15 % linearity
• CE approved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RM
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
Characteristic Measure Characteristic Measure
Load ranges11 2000 lb to 200000 lb1 Maximum allowable load 150 % FS1
Linearity Weight See table
±0.2 % full scale
100 lb to 1000 lb
Material Stainless steel
Linearity
±0.15 % full scale Deflection full scale See table
2000 lb to 50000 lb
Natural frequency See table
Linearity
±0.2 % full scale
75000 lb to 20000 lb
Hysteresis RANGE CODES
±0.2 % full scale
100 lb to 1000 lb Range Available ranges Range Available ranges
Hysteresis Code Code
±0.15 % full scale
2000 lb to 50000 lb DL 2000 lb EL 20000 lb
Hysteresis DN 3000 lb EN 30000 lb
±0.2 % full scale
75000 lb to 20000 lb
DP 4000 lb EP 50000 lb
Non-repeatability ± 0.05 % full scale
DR 5000 lb ER 75000 lb
Output (tolerance) 2 mV/V
DT 75000 lb ET 100000 lb
Operation Tension
DV 10000 lb FJ 150000 lb
Resolution Infinite
EJ 15000 lb FL 200000 lb

ENVIRONMENTAL SPECIFICATIONS
WIRING CODES
Characteristic Measure
Connector Unamplified (Std.)
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
A (+) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
B (+) excitation
Temperature effect, zero 0.005 % full scale/°F
C (-) excitation
Temperature effect, span 0.005 % full scale/°F
D (-) excitation
E (-) output
ELECTRICAL SPECIFICATIONS
F (+) output
Characteristic Measure
Strain gage type Bonded foil DEFLECTIONS AND RINGING FREQUENCIES
Excitation (calibration) 10 Vdc
Capacity (lb) Deflection at Ringing fre- Weight kg
Excitation (acceptable) Up to 15 Vdc or Vac full scale mm quency (Hz) [lb]
Insulation resistance 5000 mOhm @ 50 Vdc [in]
Bridge resistance (toler- 350 ohm 2000 0,076 [0.003] 5000 0,45 [1.0]
ance) 3000 0,076 [0.003] 5000 0,45 [1.0]
Zero balance (tolerance) ±1% full scale 4000 0,076 [0.003] 5100 0,45 [1.0]
Shunt calibration data Included 5000 0,076 [0.003] 5200 0,45 [1.0]
Electrical termination (std) PTIH-10-6P or equivalent (hermetic 7500 0,102 [0.004] 7500 0,68 [1.5]
2000 lb to 50000 lb stainless)
10000 0,102 [0.004] 7600 0,68 [1.5]
Electrical termination (std) MS3102E-14S-6P or equivalent
15000 0,127 [0.005] 8000 0,68 [1.5]
75000 lb to 200000 lb
20000 0,127 [0.005] 9800 0,68 [1.5]
Mating connector (not in- PT06A-10-6S or equivalent (AA111)
cluded) 2000 lb to 50000 lb 30000 0,127 [0.005] 8000 1,90 [4.2]
Mating connector (not MS3106A-14S-6S or equivalent (AA121) 50000 0,127 [0.005] 8200 1,90 [4.2]
included) 75000 lb to 75000 to 0,152 [0.006] 5000 7,34 [16.5]
200000 lb 100000
150000 to 0,178 [0.007] 4200 16,01 [35.3]
200000

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier Intrinsically safe
Voltage output: Voltage output: Voltage output: Current three- Current two-
specifica- amp: Option 2n
Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tions (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 18 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to
(voltage) 32 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse volt- Yes Yes Yes Yes Yes Yes
age protec-
tion
Short cir. Momentary Momentary Momentary Yes Yes Yes
protection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector B Output common B Output common** B Output common** B Output common** B No connection B No connection
(std)5 C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable5,6,7 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RM
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F8
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F8
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F8
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output 2k. 4 mA to 20 mA (two-wire)12
amplifiers 2b. 4 wire, ±5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12
2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
2j. 4 mA to 20 mA (three-wire) output
Internal amp 3a. Input/output isolation7
enhance- 3d. Remote buffered shunt calibration
ments
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) 6g. Integral cable: Neoprene
termination (ranges 50000 lb and below) 6h. Integral cable: Silicone
6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6), (max. 160 °F) (ranges above 50000 lb)6 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon 6q. Integral cable: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector on end of cable
Shunt 8a. Precision internal resistor8
calibration
Bridge type 11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Zero and 14a. No access to zero and span adjustment
span
adjustment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only Amplified only
Order code D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in]
(Unamp/Amp)
AL413/AL613 38,1 [1.50] 66,4 [2.60] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]
AL415/AL615 44,45 [1.75] 66,4 [2.60] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]
AL417/AL617 63,5 [2.50] 77,47 [3.05] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50]

THREAD SIZES AND OPTION CODES


13a 13b 13c 13d 13e
Range (lb) 1/2-20 3/4-16 7/8-14 1-14 1 1/2-12
UNF UNF UNF UNF UNF
2000 to 5000 AL413 AL413 AL413
7500 to AL415 AL415 AL415 AL417
15000
20000 AL415 AL415 AL417
30000 to AL417
50000
TYPICAL SYSTEM DIAGRAM
L2 mm [in] 24,13 24,13 24,13 31,75 38,1
[0.95] [0.95] [0.95] [1.25] [1.50]

NON-STANDARD RANGES - ORDER CODE AL411


Range (lb) Thread D mm [in] L1 mm L2 mm
type [in] [in]
75000 to 2 1/2-12 88,9 [3.50] 101,6 [4.00] 76,2 [3.00]
100000 UNF
150000 to 3 1/2-8 UNF 114,3 [4.50] 127 [5.00] 101,6 [4.00]
200000

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RM Rod End In-Line Tension Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal ampli-
fier option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i.
7. Only available with option 2b or 2c. While we provide application assistance personally, through our
8. Not available with amplified option.
9. Consult factory for TEDS availability with amplified models. literature and the Honeywell web site, it is up to the customer to
10. Termination dependent; consult factory. determine the suitability of the product in the application.
11. This unit calibrated to Imperial (non-Metric) units.
12. 5000 ohm bridge required. Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more WARNING


Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this datasheet is for
sales offices, representatives reference only. DO NOT USE this document as product
and distributors. For application installation information.
• Complete installation, operation and maintenance
assistance, current specifica-
information is provided in the instructions supplied with
tions, pricing or name of the each product.
nearest Authorized Distributor,
Failure to comply with these instructions could result in
contact your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008654-2-EN IL50 GLO 
January 2010
www.honeywell.com Copyright © 2010 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGF
Rod End In-line Compression/Tension Load Cell
DESCRIPTION
The Model RGF In-Line load cells are high quality, stainless steel completely controlled. The flexible mounting options make appli-
rugged load cells capable of withstanding significant off-axis cations easier to implement, and the all stainless steel, hermetic
loads, making them an ideal choice for in-line compression mea- construction is well suited to corrosive and very high humidity
surement or tension measurement where side loading cannot be environments.

FEATURES
• 2000 lb to 50000 lb range
• Female/female threads
• Stainless steel, all-welded construction
• 1 mV/V nominal (standard); 0 Vdc to 5 Vdc or 4 mA to 20
mA outputs (optional)
• Compression/tension
• 0.25 % accuracy
• CE approved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGF
PERFORMANCE SPECIFICATIONS RANGE CODES
Characteristic Measure Range Code Available ranges
Load ranges11 2000, 3000, 5000, 10000, 15000, 25000, DL 2000 lb
50000 lb
DN 3000 lb
Accuracy ±0.25 % full scale1
DR 5000 lb
Linearity ±0.25 % full scale
DV 10000 lb
Hysteresis ±0.25 % full scale
EJ 15000 lb
Non-repeatability ± 0.05 % full scale
EM 25000 lb
Output (tolerance) 1 mV/V (nominal)
EP 50000 lb
Operation Tension/compression
Resolution Infinite
WIRING CODES
Connector Unamplified (Std.)
ENVIRONMENTAL SPECIFICATIONS A (+) excitation
Characteristic Measure B (+) excitation
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] C (-) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] D (-) excitation
Temperature effect, zero 0.005 % full scale/°F E (-) output
Temperature effect, span 0.005 % full scale/°F F (+) output

ELECTRICAL SPECIFICATIONS
Characteristic Measure
DEFLECTIONS AND RINGING FREQUENCIES
Strain gage type Bonded foil Capacity (lb) Deflection at Ringing fre- Weight kg
full scale mm quency (Hz) [lb]
Excitation (calibration) 10 Vdc [in]
Excitation (acceptable) Up to 15 Vdc or Vac 2000 0,025 [0.001] 10000 0,55 [1.2]
Insulation resistance 5000 mOhm @ 50 Vdc 3000 0,025 [0.001] 12000 0,55 [1.2]
Bridge resistance (toler- 700 ohm 5000 0,050 [0.002] 15000 0,63 [1.4]
ance)
10000 0,050 [0.002] 10000 1,3 [2.9]
Shunt calibration data Included
15000 0,050 [0.002] 10000 1,3 [2.9]
Electrical termination (std) PTIH-10-6P or equivalent (hermetic
stainless) 25000 0,050 [0.002] 6500 4,3 [9.5]
50000 0,076 [0.003] 7000 4,49 [9.9]

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Case material Stainless steel
Life cycles (approx) >10 million cycles
Deflection full scale 0,076 mm [0.003 in]

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Compression/Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier Intrinsically safe
Voltage output: Voltage output: Voltage output: Current three- Current two-
specifica- amp: Option 2n
Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tions (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to
(voltage) 32 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse volt- Yes Yes Yes Yes Yes Yes
age protec-
tion
Short cir. Momentary Momentary Momentary Yes Yes Yes
protection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector B Output common B Output common** B Output common** B Output common** B No connection B No connection
(std)4 C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable4,5,6 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS2


Capacity (lb) Side load (lb) Torque (lb-in)
(% of load capac- (% of load capac-
ity) ity)
2000 20 % 20 %
3000 20 % 20 %
5000 20 % 20 %
10000 20 % 20 %
15000 20 % 20 %
25000 20 % 20 %
50000 20 % 20 %

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGF
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2K, 3K, 5K, 10K, 15K, 25K, 50K lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F8
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F8
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F8
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output 2j. 4 mA to 20 mA (three-wire) output
amplifiers 2b. 4 wire, ±5 Vdc output 2k. 4 mA to 20 mA (two-wire)13
2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
Internal amp 3a. Input/output isolation7
enhance- 3d. Remote buffered shunt calibration
ments
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) 6g. Integral cable: Neoprene
termination (ranges 50000 lb and below) 6h. Integral cable: Silicone
6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6), (max. 160 °F) (ranges above 50000 lb)6 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon 6q. Integral cable: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector on end of cable
Shunt 8a. Precision internal resistor8
calibration
Bridge type 11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Zero and 14a. No access to zero and span adjustment
span
adjustment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Compression/Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only Amplified only
Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in]
2000 to 5000 44,45 [1.75] 3/4-16 UNF 24,13 [0.95] 90,42 [3.56] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]
10000 to 15000 63,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 155,54 [6.12] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]
25000 to 50000 88,9 [3.50] 2-12 UNF 57,15 [2.25] 203,2 [8.00] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGF Rod End In-Line Compression/Tension Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal ampli-
fier option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
7. Only available with option 2b or 2c. While we provide application assistance personally, through our
8. Not available with amplified option.
9. Consult factory for TEDS availability with amplified models. literature and the Honeywell web site, it is up to the customer to
10. Termination dependent; consult factory. determine the suitability of the product in the application.
11. This unit calibrated to Imperial (non-Metric) units.
12. 5000 ohm bridge required. Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more WARNING


Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this datasheet is for
sales offices, representatives reference only. DO NOT USE this document as product
and distributors. For application installation information.
• Complete installation, operation and maintenance
assistance, current specifica-
information is provided in the instructions supplied with
tions, pricing or name of the each product.
nearest Authorized Distributor,
Failure to comply with these instructions could result in
contact your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008659-2-EN IL50 GLO 
January 2010
www.honeywell.com Copyright © 2010 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGH
Rod End In-line Compression/Tension Load Cell
DESCRIPTION
The Model RGH In-Line load cells are high quality, stainless cannot be completely controlled. The flexible mounting options
steel, rugged load cells capable of withstanding significant make applications easier to implement, and the all stainless
off-axis loads, making them an ideal choice for in-line compres- steel, hermetic construction is well suited to corrosive and very
sion measurement or tension measurement where side loading high humidity environments.

FEATURES
• 2000 lb to 50000 lb range
• Male/female threads
• Stainless steel, all-welded construction
• 1 mV/V nominal (standard); 0 Vdc to 5 Vdc or 4 mA to 20
mA outputs (optional)
• Compression/tension
• 0.25 % accuracy
• CE approved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGH
PERFORMANCE SPECIFICATIONS RANGE CODES
Characteristic Measure Range Code Available ranges
Load ranges 11
2000, 3000, 4000, 5000, 10000, 15000, DL 2000 lb
25000, 50000 lb
DN 3000 lb
Accuracy ±0.25 % full scale1
DP 4000 lb
Linearity ±0.25 % full scale
DR 5000 lb
Hysteresis ±0.25 % full scale
DV 10000 lb
Non-repeatability ± 0.05 % full scale
EJ 15000 lb
Output (tolerance) 1 mV/V (nominal)
EM 25000 lb
Operation Tension/compression
EP 50000 lb
Resolution Infinite

WIRING CODES
ENVIRONMENTAL SPECIFICATIONS Connector Unamplified (Std.)
Characteristic Measure A (+) excitation
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] B (+) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] C (-) excitation
Temperature effect, zero 0.005 % full scale/°F D (-) excitation
Temperature effect, span 0.005 % full scale/°F E (-) output
F (+) output
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
DEFLECTIONS AND RINGING FREQUENCIES
Excitation (calibration) 10 Vdc Capacity (lb) Deflection at Ringing fre- Weight kg
full scale mm quency (Hz) [lb]
Excitation (acceptable) Up to 15 Vdc or Vac [in]
Insulation resistance 5000 mOhm @ 50 Vdc 2000 0,025 [0.001] 10000 0,55 [1.2]
Bridge resistance (toler- 700 ohm 3000 0,025 [0.001] 12000 0,55 [1.2]
ance)
4000 0.038 [0.0015] 13000 0,59 [1.3]
Shunt calibration data Included
5000 0,050 [0.002] 15000 0,63 [1.4]
Electrical termination (std) PTIH-10-6P or equivalent (hermetic
stainless) 10000 0,050 [0.002] 10000 1,3 [2.9]
15000 0,050 [0.002] 10000 1,3 [2.9]
25000 0,050 [0.002] 6500 4,3 [9.5]
50000 0,076 [0.003] 7000 4,3 [9.5]
MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Case material Stainless steel
Life cycles (approx) >10 million cycles
Deflection full scale 0,076 mm [0.003 in]

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Compression/Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier Intrinsically safe
Voltage output: Voltage output: Voltage output: Current three- Current two-
specifica- amp: Option 2n
Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tions (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to
(voltage) 32 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse volt- Yes Yes Yes Yes Yes Yes
age protec-
tion
Short cir. Momentary Momentary Momentary Yes Yes Yes
protection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector B Output common B Output common** B Output common** B Output common** B No connection B No connection
(std)4 C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable4,5,6 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS2


Capacity (lb) Side load (lb) Torque (lb-in)
(% of load capac- (% of load capac-
ity) ity)
2000 20 % 20 %
3000 20 % 20 %
4000 20 % 20 %
5000 20 % 20 %
10000 20 % 20 %
15000 20 % 20 %
25000 20 % 20 %
50000 20 % 20 %

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGH
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F8
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F8
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F8
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output 2j. 4 mA to 20 mA (three-wire) output
amplifiers 2b. 4 wire, ±5 Vdc output 2k. 4 mA to 20 mA (two-wire)13
2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
Internal amp 3a. Input/output isolation7
enhance- 3d. Remote buffered shunt calibration
ments
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) 6g. Integral cable: Neoprene
termination (ranges 50000 lb and below) 6h. Integral cable: Silicone
6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6), (max. 160 °F) (ranges above 50000 lb)6 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon 6q. Integral cable: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector on end of cable
Shunt 8a. Precision internal resistor8
calibration
Bridge type 11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Zero and 14a. No access to zero and span adjustment
span
adjustment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Compression/Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only Amplified only
Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in]
2000 to 5000 44,45 [1.75] 3/4-16 UNF 24,13 [0.95] 66,80 [2.63] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]
10000 to 15000 63,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 114,3 [4.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]
25000 to 50000 88,9 [3.50] 2-12 UNF 57,15 [2.25] 146,05 [5.75] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGH Rod End In-Line Compression/Tension Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal ampli-
fier option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i.
7. Only available with option 2b or 2c. While we provide application assistance personally, through our
8. Not available with amplified option.
9. Consult factory for TEDS availability with amplified models. literature and the Honeywell web site, it is up to the customer to
10. Termination dependent; consult factory. determine the suitability of the product in the application.
11. This unit calibrated to Imperial (non-Metric) units.
12. 5000 ohm bridge required.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this datasheet is for
reference only. DO NOT USE this document as product
Find out more installation information.
Honeywell serves its customers • Complete installation, operation and maintenance
through a worldwide network of information is provided in the instructions supplied with
each product.
sales offices, representatives
Failure to comply with these instructions could result in
and distributors. For application
death or serious injury.
assistance, current specifica-
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
008658-2-EN IL50 GLO 
Golden Valley, MN 55422 January 2010
Copyright © 2010 Honeywell International Inc. All rights reserved.
www.honeywell.com

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGM
Rod End In-line Tension/Compression Load Cell
DESCRIPTION
The Model RGM In-Line load cells are high quality, stainless cannot be completely controlled. The flexible mounting options
steel, rugged load cells capable of withstanding significant make applications easier to implement, and the all stainless
off-axis loads, making them an ideal choice for in-line compres- steel, hermetic construction is well suited to corrosive and very
sion measurement or tension measurement where side loading high humidity environments.

FEATURES
• 2000 lb to 50000 lb range
• Male/male threads
• Stainless steel, all-welded construction
• 1 mV/V nominal (standard); 0 Vdc to 5 Vdc or 4 mA to 20
mA outputs (optional)
• Compression/tension
• 0.25 % accuracy
• CE approved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGM
PERFORMANCE SPECIFICATIONS RANGE CODES
Characteristic Measure Range Code Available ranges
Load ranges 11
2000, 3000, 4000, 5000, 10000, 15000, DL 2000 lb
25000, 50000 lb
DN 3000 lb
Accuracy ±0.25 % full scale
DP 4000 lb
Linearity ±0.25 % full scale
DR 5000 lb
Hysteresis ±0.25 % full scale
DV 10000 lb
Non-repeatability ± 0.05 % full scale
EJ 15000 lb
Output (tolerance) 1 mV/V (nominal)
EM 25000 lb
Operation Tension/compression
EP 50000 lb
Resolution Infinite

WIRING CODES
ENVIRONMENTAL SPECIFICATIONS Connector Unamplified (Std.)
Characteristic Measure A (+) excitation
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] B (+) excitation
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] C (-) excitation
Temperature effect, zero 0.005 % full scale/°F D (-) excitation
Temperature effect, span 0.005 % full scale/°F E (-) output
F (+) output
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
DEFLECTIONS AND RINGING FREQUENCIES
Excitation (calibration) 10 Vdc Capacity (lb) Deflection at Ringing fre- Weight kg
full scale mm quency (Hz) [lb]
Excitation (acceptable) Up to 15 Vdc or Vac [in]
Insulation resistance 5000 mOhm @ 50 Vdc 2000 0,025 [0.001] 10000 0,55 [1.2]
Bridge resistance (toler- 700 ohm 3000 0,025 [0.001] 12000 0,55 [1.2]
ance)
4000 0.038 [0.0015] 13000 0,59 [1.3]
Zero balance (tolerance) ±3 % full scale
5000 0,050 [0.002] 15000 0,63 [1.4]
Shunt calibration data Included
10000 0,050 [0.002] 10000 1,3 [2.9]
Electrical termination (std) PTIH-10-6P or equivalent (hermetic
stainless) 15000 0,050 [0.002] 10000 1,3 [2.9]
25000 0,050 [0.002] 6500 4,3 [9.5]
50000 0,076 [0.003] 7000 4,3 [9.5]
MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Weight See table
Material Stainless steel
Life cycles (approx) >10 million cycles
Deflection full scale See table
Natural frequency See table

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Compression/Tension Load Cell
INTERNAL AMPLIFIERS
Amplifier Intrinsically safe
Voltage output: Voltage output: Voltage output: Current three- Current two-
specifica- amp: Option 2n
Option 2b Option 2c Option 2t wire: Option 2j wire: Option 2k
tions (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V 0 V to 10 V or ±10 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA V @ 45 mA
Input power ±15 V or 26 Vdc to 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to
(voltage) 32 Vdc 28 Vdc
Input power 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power supply 60 db 60 db 60 db 60 db 60 db 60 db
rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse volt- Yes Yes Yes Yes Yes Yes
age protec-
tion
Short cir. Momentary Momentary Momentary Yes Yes Yes
protection
Wiring code: A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
connector B Output common B Output common** B Output common** B Output common** B No connection B No connection
(std)4 C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
cable4,5,6 Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS2


Capacity (lb) Side load (lb) Torque (lb-in)
(% of load capac- (% of load capac-
ity) ity)
2000 20 % 20 %
3000 20 % 20 %
4000 20 % 20 %
5000 20 % 20 %
10000 20 % 20 %
15000 20 % 20 %
25000 20 % 20 %
50000 20 % 20 %

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGM
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F8
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F8
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F8
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal 2u. Unamplified, mV/V output 2j. 4 mA to 20 mA (three-wire) output
amplifiers 2b. 4 wire, ±5 Vdc output 2k. 4 mA to 20 mA (two-wire)12
2c. 0 Vdc to 5 Vdc 2t. 0 Vdc to 10 Vdc output
Internal amp 3a. Input/output isolation7
enhance- 3d. Remote buffered shunt calibration
ments
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 °F) 6g. Integral cable: Neoprene
termination (ranges 50000 lb and below) 6h. Integral cable: Silicone
6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6), (max. 160 °F) (ranges above 50000 lb)6 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon 6q. Integral cable: Polyurethane
6f. Integral cable: PVC 6v. Phoenix connector on end of cable
Shunt 8a. Precision internal resistor8
calibration
Bridge type 11a. Square bridge8
11b. Symmetrical bridge8
11c. Square and symmetrical bridge8
31a. Dual bridge
Bridge 12b. 5000 ohm (foil) (max. 250 °F)
resistance
Zero and 14a. No access to zero and span adjustment
span
adjustment
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration8
53t. TEDS IEEE 1451.4 module9

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rod End In-Line Compression/Tension Load Cell
MOUNTING DIMENSIONS
Unamplified only Amplified only
Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in]
2000 to 5000 44,45 [1.75] 3/4-16 UNF 24,13 [0.95] 66,80 [2.63] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]
10000 to 15000 63,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 88,9 [3.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]
25000 to 50000 88,9 [3.50] 2-12 UNF 57,15 [2.25] 88,9 [3.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50]

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model RGM Rod End In-Line Compression/Tension Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal Honeywell during the period of coverage, Honeywell will repair
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire or replace, at its option, without charge those items it finds
units) or 80 % (voltage amplified units) of full scale output for quick
defective. The foregoing is buyer’s sole remedy and is in lieu
calibration. Shunt calibration comes standard with internal ampli-
fier option 2a, 2b, 2c, 2t and 2j. of all warranties, expressed or implied, including those of
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; merchantability and fitness for a particular purpose. In no
W=White; G=Green. Color specifying cable and number or letter
specifying connector. event shall Honeywell be liable for consequential, special, or
5. No mating connector necessary for cable option. indirect damages.
6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.
7. Only available with option 2b or 2c. While we provide application assistance personally, through our
8. Not available with amplified option.
9. Consult factory for TEDS availability with amplified models. literature and the Honeywell web site, it is up to the customer to
10. Termination dependent; consult factory. determine the suitability of the product in the application.
11. This unit calibrated to Imperial (non-Metric) units.
12. 5000 ohm bridge required. Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more WARNING


Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this datasheet is for
sales offices, representatives reference only. DO NOT USE this document as product
and distributors. For application installation information.
• Complete installation, operation and maintenance
assistance, current specifica-
information is provided in the instructions supplied with
tions, pricing or name of the each product.
nearest Authorized Distributor,
Failure to comply with these instructions could result in
contact your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008657-3-EN IL50 GLO 
January 2010
www.honeywell.com Copyright © 2010 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3124
Tension/Compression In-Line Load Cell
DESCRIPTION
The small-diameter, cost-efficient load cells are designed to They may be directly attached to the piston rod of a hydraulic
be used in applications that require an ability to mount in an cylinder. Side-mounted cable connectors allow cable assemblies
existing system with restricted working area. They are commonly to be supported without affecting movement of the cell during
used in fluid power transfer systems. Their low cost and ease of tension or compression loading.
mounting allow simultaneous testing of multi-element systems.

FEATURES
• 5000 lb to 25000 lb range
• 0.25 % non-linearity
• 0.15 % hysteresis
• Adapts directly to hydraulic cylinder
• Small diameter allows mounting in restricted areas
• Low deflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3124

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Code Available ranges
Load range 1
5000, 10000, 15000, 20000, 25000 lb DR 5000 lb
Non-linearity ±0.25 % of rated output DV 10000 lb
Hysteresis ±0.15 % of rated output EJ 15000 lb
Repeatability ±0.05 % of rated output EL 20000 lb
Output @ rated capacity ±2 mV/V (nominal) EM 25000 lb
Operation Tension/compression
Resolution Infinite
TYPICAL SYSTEM DIAGRAM
Standard calibration Tension (+) and compression (-)
In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder
ENVIRONMENTAL SPECIFICATIONS Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Characteristic Measure Computer
UV +/-5 VDC
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] U3W 4-20mA (3 wire)
Temperature effect, zero ±0.002 % of rated output/°F U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Temperature effect, output ±0.002 % of reading/°F DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)
ELECTRICAL SPECIFICATIONS
Characteristic Measure Honeywell
In-Line Amplifier

Strain gage type Foil


Output Input
Serial Number

Excitation (maximum) 20 Vdc or Vac RMS


Display Units
Insulation resistance > 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm SC500 SC1000 SC2000
(tolerance) SC2001 SC3004
GM NK HH
Number of bridges 1 or 2 MODEL 3124 7541 7558 7561-PSD
Zero balance ±1.0 %

2003.1 lb.
MECHANICAL SPECIFICATIONS OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE

Characteristic Measure UP DOWN SETUP ENTER EXIT

Static overload capacity 150 % of nominal capacity


Material Carbon steel Mating Connectors & Cables
Natural frequency See table 064-LW13621 Mating connector
7200-76-XX* Mating connector and six conductor cable
(unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
(unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression In-Line Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
5K 20K 150 n/a 250 750 15000 0.005 4600
10K 50K 150 n/a 250 700 1100 0.005 6400
15K 75K 150 n/a 450 1300 2100 0.005 7700
20K 100K 150 n/a 650 2000 3000 0.005 8800
25K 125K 150 n/a 950 2700 4500 0.005 9600

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]
3124 11,43 [4.50] 2,54 [1.0] 0,97 [0.38] 2,06 [0.81] 3,81 [1.50] 3,51 [1.38] 6,20 [2.44] 4,37 [1.72]

RECEP.
MS-3102E-14S-5P
E
HEX

1.0-14 THD. H

F DIA. 1.0-14 THD.


B DEEP
E DIA.

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3124 Tension/Compression In-Line Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008661-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3161
Tension/Compression In-Line Load Cell
DESCRIPTION
The small-diameter, cost-efficient, fatigue-resistant load cells They may be directly attached to the piston rod of a hydraulic
are designed to be used in applications that require an ability to cylinder. Side-mounted cable connectors allow cable assemblies
mount in an existing system with restricted working area. They to be supported without affecting movement of the cell during
are commonly used in fluid power transfer systems. Their low tension or compression loading.
cost and ease of mounting allow simultaneous testing of multi-
element systems.

FEATURES
• 2000 lb to 25000 lb range
• 0.15 % linearity
• 0.1 % hysteresis
• Fatigue resistant
• Adapts directly to hydraulic cylinder
• Small diameter allows mounting in restricted areas
• Low deflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3161

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Code Available ranges
Load range 1
2000, 5000, 10000, 25000 lb DL 2000 lb
Non-linearity ±0.15 % of rated output DR 5000 lb
Hysteresis ±0.1 % of rated output DV 10000 lb
Repeatability ±0.05 % of rated output EM 25000 lb
Output @ rated capacity ±2 mV/V (nominal)
Operation Tension/compression
TYPICAL SYSTEM DIAGRAM
Resolution Infinite
In-Line Amplifiers Customer Supplied
Standard calibration Tension (+) and compression (-) (Used with unamplified units only) Chart Recorder
Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
ENVIRONMENTAL SPECIFICATIONS UV +/-5 VDC Computer
Characteristic Measure UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
DIN rail Mount In-Line Amplifiers
Temperature effect, zero ±0.002 % of rated output/°F DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
Temperature effect, output ±0.002 % of reading/°F DV10 0 +/- 10 VDC (3 wire)

ELECTRICAL SPECIFICATIONS Honeywell


In-Line Amplifier

Characteristic Measure
Output Input
Serial Number

Strain gage type Foil MODEL 3161


Display Units
Excitation (maximum) 20 Vdc or Vac RMS
SC500 SC1000 SC2000
Insulation resistance > 5000 mOhm @ 50 Vdc
SC2001 SC3004
Bridge resistance 350 ohm GM NK HH
(tolerance) 7541 7558 7561-PSD

Number of bridges 1 or 2
Zero balance ±1.0 %
2003.1 lb.
OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE

MECHANICAL SPECIFICATIONS UP DOWN SETUP ENTER EXIT

Characteristic Measure
Static overload capacity 150 % of nominal capacity Mating Connectors & Cables

Material Carbon steel 023-LW181-023-LF Mating Connector


7205-76-XX* Mating connector & 6 conductor cable
Natural frequency See table (unamplified unit with sense leads but not shunt cal)
7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)

* XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression In-Line Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static Fatigue Shear FX or Bending MX Torque MZ Deflection Ringing
overload capacity (% FY (lb) or MY (lb-in) (lb-in) at nominal frequency
capacity (% of nominal load limit (Hz)
of nominal capacity) (in)
capacity)
2K 10K 150 100 850 3800 3500 0.003 5000
5K 20K 150 100 850 3800 3500 0.003 6200
10K 50K 150 100 850 3800 3500 0.003 7100
25K 125K 150 100 2040 6750 9600 0.003 11000

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]
3161 17,48 [6.88] 2,54 [1.0] 11,28 [4.44] 4,29 [1.69] 6,05 [2.38] 1,27 [0.50] 4,14 [1.63] 0,64 [0.25]

RECEP.
PT02E-10-6P

1.0-14 THD.
OPTIONAL B DEEP
DUAL BRIDGE

D 1.0-14 THD.

C OPTIONAL
DUAL BRIDGE

9/32 DIA. M DEEP


4 HOLES EQUALLY SPACED
D FOR SPANNER WRENCH
F

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3161 Tension/Compression In-Line Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008660-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3336
Tension/Compression Donut Load Cell
DESCRIPTION
Model 3336 Tension/Compression Donut Load Cell features a The precision design and manufacture of this versatile
smooth thru-hole design for use in applications which require the transducer style is the result of our experience in the metal
load structure to pass through the cell. The hollow load cells are working industry and automotive applications.
available for tension-compression loads in capacities of 5K, 10K
and 20K lbs.

FEATURES
• 5000 lb to 5000 lb range
• Thru-hole design
• Compact column construction
• mV/V output
• 0.25 % linearity

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3336

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder
Load range 1
5000, 10000, 20000 lb
Alarm Panel
Non-linearity ±0.25 % of rated output Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.15 % of rated output UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC
Repeatability ±0.15 % of rated output UBP 0 +/-5 VDC
Output @ rated capacity ±2 mV/V (nominal) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Operation Tension/compression DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
Resolution Infinite
DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) DV10 0 +/- 10 VDC (3 wire)

Honeywell
ENVIRONMENTAL SPECIFICATIONS In-Line Amplifier
Output Input
Serial Number

Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] SC500 SC1000 SC2000
Temperature effect, zero ±0.002 % of rated output/°F SC2001 SC3004
GM NK HH
Temperature effect, output ±0.002 % of reading/°F 7541 7558 7561-PSD

MODEL 3336
ELECTRICAL SPECIFICATIONS
2003.1 lb.
Characteristic Measure OR L1 L2 L3 L4

Strain gage type Foil


VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

Excitation (maximum) 20 Vdc or Vac RMS


Insulation resistance > 5000 mOhm @ 50 Vdc Mating Connectors & Cables
Bridge resistance, 5K lb 350 ohm
064-LW13621 Mating connector
Bridge resistance, (tol.) 700 ohm 7200-76-XX* Mating connector and six conductor cable
10K, 20 K lb (unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
Number of bridges 1 or 2 (unamplified sensor without sense leads)
Zero balance ±1.0 % 7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
Electrical termination MS3102E-14S-5P
7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
* XX represents length in feet 100ft maximum
MECHANICAL SPECIFICATIONS ** XX represents length in feet 20ft maximum
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material Aluminum
Natural frequency See table

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tension/Compression Donut Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static over- Shear FX or Bending MX Torque MZ Deflection at Ringing fre-
load capacity FY (lb) or MY (lb-in) (lb-in) nominal load quency (Hz)
(% of nominal limit (in)
capacity)
5K 20K 150 550 12K 1850 0.005 1100
10K 50K 150 1400 31K 3750 0.005 1500
20K 100K 150 2650 62K 14K 0.005 2200

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]
3336 22,86 [9] 12,70 [5] 8,26 [3.25] 1,91 [0.75] 12,40 [4.88] 17,78 [7]

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3336 Tension/Compression Donut Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008652-2-EN IL50 GLO 
+1-815-235-6847 December 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3632
Compression Donut Load Cell
DESCRIPTION
Model 3632 Compression Donut Load Cell features a smooth available for compression only loads in capacities of 25K, 50K
thru-hole design for use in applications which require the load and 100K lbs. For optimum performance, this load cell must be
structure to pass through the cell. The hollow load cells are mounted between load surfaces which are flat and parallel.

FEATURES
• 25000 lb to 100000 lb range
• Thru-hole design
• Compact column construction
• mV/V output
• 0.15 % linearity

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3632

PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM


Characteristic Measure In-Line Amplifiers Customer Supplied
(Used with unamplified units only) Chart Recorder
Load range 1
25000, 50000, 100000 lb
Alarm Panel
Non-linearity ±0.15 % of rated output Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Hysteresis ±0.15 % of rated output UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC
Repeatability ±0.15 % of rated output UBP 0 +/-5 VDC
Output @ rated capacity 2 mV/V (nominal) U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Operation Compression DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
Resolution Infinite
DA-05 4-20mA (3 wire)
Standard calibration Tension (+) and compression (-) DV10 0 +/- 10 VDC (3 wire)

Honeywell
ENVIRONMENTAL SPECIFICATIONS In-Line Amplifier
Output
Serial Number
Input

Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] Display Units
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] SC500 SC1000 SC2000
Temperature effect, zero ±0.002 % of rated output/°F SC2001 SC3004
GM NK HH
Temperature effect, output ±0.002 % of reading/°F 7541 7558 7561-PSD
MODEL 3632
ELECTRICAL SPECIFICATIONS
2003.1 lb.
Characteristic Measure OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE

Strain gage type Foil UP DOWN SETUP ENTER EXIT

Excitation (maximum) 20 Vdc or Vac RMS


Insulation resistance > 5000 mOhm @ 50 Vdc Mating Connectors & Cables

Bridge resistance, 25K lb, 480 ohm 023-LW181-023-LF Mating Connector


7205-76-XX* Mating connector & 6 conductor cable
50K lb (unamplified unit with sense leads but not shunt cal)
Bridge resistance, 100K lb 240 ohm 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
Number of bridges 1 7205-83-XX* Mating connector & 6 conductor cable
Zero balance ±1.0 % (for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
Electrical termination PT02E-10-6P (for connection to instrument 7541)

* XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum
MECHANICAL SPECIFICATIONS
Characteristic Measure
Static overload capacity 150 % of nominal capacity
Material Carbon steel
Natural frequency See table

WIRING CODES
Cable
Red (+) excitation
Black (-) excitation
Green (+) output
White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compression Donut Load Cell

NATURAL FREQUENCY
Nominal load limit Static extraneous load limits
capacity Fz
lb N Static over- Shear FX or Bending MX Torque MZ Deflection at Ringing fre-
load capacity FY (lb) or MY (lb-in) (lb-in) nominal load quency (Hz)
(% of nominal limit (in)
capacity)
25K 125K 150 2750 18K 3K 0.005 5000
50K 200K 150 5500 36K 13K 0.005 7000
100K 500K 150 13K 91K 27K 0.005 10000

MOUNTING DIMENSIONS
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]
3632 10,16 [4] 5,08 [2] 7,62 [3] 5,08 [2] 2,54 [1] 8,26 [3.25] 0,15 [0.06] 4,78 [1.88]

A DIA.

B DIA.

RECEP.
PT02E-10-6P

F
E G

D H

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3632 Compression Donut Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008651-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MPB
High Capacity Compact Compression Load Cell
DESCRIPTION
The compact Model MPB Load Cells are designed for Applications include impact testing and mine shaft roof
applications requiring high capacity yet where space restrictions simulations. The diameter of these load cells range between
require that the cell be small in size. The Model MPB will 1.25 in and 10 in while the height ranges between approximately
measure compression load forces in ranges between 15,000 to 0.63 in and 14 in depending on the load range desired.
2,000,000 pounds.

FEATURES
• 8 ton to 1000 ton range
• Stainless steel
• mV/V output
• 0.25 % accuracy
• CE approved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MPB

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Available ranges Range Available ranges
Load ranges 9
1 ton to 1000 ton Code Code
Accuracy ± 0.25 % best fit straight line2 DL 1 ton ET 50 ton

Non-repeatability ± 0.02 % full scale DR 2.5 ton FL 100 ton

Output (tolerance) 2 mV/V (nominal)


DV 5 ton FR 250 ton
EL 10 ton FT 500 ton
Operation Compression
EP 25 ton FV 1000 ton
Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS WIRING CODES


Characteristic Measure Connector Unamplified
Temperature, operating -57 °C to 121 °C [-70 °F to 250 °F] A (+) excitation

Temperature, compensated 21 °C to 71 °C [70 °F to 160 °F] B (+) excitation

Temperature, storage -73 °C to 149 °C [-100 °F to 300 °F] C (-) excitation


Temperature effect, zero 0.005 % full scale/°F D (-) excitation
Temperature effect, span 0.005 % full scale/°F E (-) output
F (+) output

ELECTRICAL SPECIFICATIONS
Wire
Characteristic Measure
Red (+) excitation
Strain gage type Bonded foil
Black (-) excitation
Excitation (calibration) 10 Vdc
Green (-) output
Insulation resistance 5,000 mOhm @ 50 Vdc
White (+) output
Bridge resistance (toler- 350 ohm (nominal)
ance)
Zero balance (tolerance) ± 1% of full scale TYPICAL SYSTEM DIAGRAM
Shunt calibration data Included
Electrical termination (std) Cable
1 ton to 5 ton
Electrical termination (std) Connector
10 ton to 1000 ton

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS3
Material All welded stainless steel
Life cycles (approx.) 1 million cycles

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Capacity Compact Compression Load Cell

INTERNAL AMPLIFIERS
Amplifier Voltage out- Voltage out- Vehicle volt- Vehicle volt- Current three- Current two- Intrinsically
specifica- put: put: age output: age output: wire: wire: safe amp: Op-
tions Option 2a Option 2b Option 2c Option 2t Option 2j Option 2k tion 2n (2N)***
Output 0 V to 5 V ±5 V 0 V to 5 V or ±5 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
signal V @ 45 mA ±10 V @ 45 mA
Input power ±15 V or 26 Vdc ±15 V or 26 Vdc 18 Vdc to 28 15 Vdc to 28 22 Vdc to 32 9 Vdc to 32 Vdc 9 Vdc to
(voltage) to 32 Vdc to 32 Vdc Vdc Vdc Vdc 28 Vdc
Input power 45 mA 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
(current)
Freq. resp 3000 Hz 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
(amp)
Power sup- 60 db 60 db 60 db 60 db 60 db 60 db 60 db
ply rej.
Operating -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
temp.
Reverse Yes Yes Yes Yes Yes Yes Yes
voltage
protection
Short cir. Momentary Momentary Momentary Momentary Yes Yes Yes
protection
Wiring A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
code: B (-)Output/supply B (-)Output/supply B Output com- B (-) output B Output com- B No connection B No connection
connector C (-)Supply C (-)Supply mon** C Supply return mon** C No connection C No connection
(std) D (+) Output D (+) Output C Supply return ** D (+) Output C Supply return** D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 D (+) Output E Shunt cal 1 D (+) Output E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 E Shunt cal 1 F Shunt cal 2 E Shunt cal 1 F No connection F No connection
F Shunt cal 2 F Shunt cal 2

Wiring R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
code: Br (-) Supply Br (-) Supply Bl Output com- Bl Supply return Bl Output com- Bl (+) Output Bl (+) Output
cable4,5,6 O (-)Output/supply O (-)Output/supply mon* G (+) Output mon* W Case ground W Case ground
G (+) Output G (+) Output G Supply return* W (+) Output G Supply return*
B Shunt cal 1 B Shunt cal 1 W (+) Output B Shunt cal 1 W (+) Output
Y Shunt cal 2 Y Shunt cal 2 B Shunt cal 1 Br Shunt cal 2 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MPB
OPTION CODES NOTES
Many range/option combinations are available in 1. For standard configuration with spherical radius, a hardened
our quick-ship and fast-track manufacture pro- surface is recommended to maintain the best loading conditions.
grams. Please see http://sensing.honeywell.com/ RC42 is recommended minimum hardness. Bearing lubricant at
TMsensor-ship for updated listings. loading interface recommended for maximum life.
2. Accuracies stated are expected for best-fit, straight-line for all er-
Load ranges 1, 2.5, 5, 10, 25, 50, 100, 250, 500, 1000 ton
rors including linearity, hysteresis and non-repeatability thru zero.
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F10 3. Allowable maximum loads – Maximum load to be applied without
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F10 damage.4
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F10 4. Without damage – loading to this level will not cause excessive
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C zero shift or performance degradation. The user must consider
fatigue life for long term use and structural integrity. All structur-
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
ally critical applications (overhead loading, etc.) should always be
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C designed with safety redundant load paths.
Internal 2a. Four-wire, 0 Vdc to 5 2n (2N) 4 mA to 20 mA 5. Special wiring code.
amplifiers6, 7 Vdc output (two-wire) intrinsically 6. Not available with option 1e, 1f, 1g, 1h, or 1i.
2c. 0 Vdc to 5 Vdc safe11 7. Amplifier option not available with low ranges. Consult factory.
8. Consult factory for TEDS availability with amplified models.
2j. 4 mA to 20 mA (three- 2t. 0 Vdc to 10 Vdc
9. This unit calibrated to Imperial (non-Metric) units.
wire) output output 10. Non-amplified only.
2k. 4 mA to 20 mA (two- 2u. Unamplified, mV/V 11. 5000 ohm bridge required.
wire)11 output
Electrical 6a. Bendix PTIH-10-6P 6g. Integral cable:
termination (or equivalent), 6-pin Neoprene (0 °F to
(max. 250 °F) 180 °F)6
6b. MS3102E-14S-6P 6i. Integral underwater
connector (10 ton to cable (max. 180 °F)6
1000 ton range)5 6j. 1/2-14 conduit fitting
6e. Integral cable: Teflon 6q. Integral cable: Poly-
(1 ton to 5 ton range) urethane
6f. Integral cable: PVC 6v. Phoenix connector
(-20 °F to 160 °F) on end of cable
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
Shunt cali- 8a. Precision internal resistor (max. 250 °F)10
bration
Bridge type 11a. Square bridge10
11b. Symmetrical bridge10
11c. Square and symmetrical bridge10
31a. Dual bridge
Bridge resist- 12b. 5000 ohm (foil) (max. 250 °F)
ance
Special cali- 30a. Positive in compression, compression testing
bration only
9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
9b. 20 point (10 up/10 down) 10 % increments @
70 °F
9c. ASTM E-74 calibration
9e. CE mark
30c. Negative in compression, compression testing
only
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration5
53t. TEDS IEEE 1451.4 module8

4 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MPB High Capacity Compact Compression Load Cell
MOUNTING DIMENSIONS
Capaci- D0 mm [in] D1 mm [in] D2 mm [in] L1 mm [in] L2 mm [in] L3 mm [in] H mm [in] Thread Optional
ty (tons) lifting eye bottom
(v.s.) thread
1 6,6 [0.26] 22,1 [0.87] 9,4 [0.37] 19,05 [0.75] 0,51 [0.02] 1,52 [0.06] 9,53 [0.375] NA 8-32 UNC x
0.18 in deep
2.5 6,6 [0.26] 22,1 [0.87] 9,4 [0.37] 19,05 [0.75] 0,51 [0.02] 1,52 [0.06] 9,53 [0.375] NA 8-32 UNC x
0.18 in deep
5 10,41 [0.41] 24,89 [0.98] 13,46 [0.53] 22,35 [0.88] 1,02 [0.04] 1,52 [0.06] 9,53 [0.375] NA 8-32 UNC x
0.18 in deep
10 19,05 [0.75] 37,85 [1.49] 19,05 [0.75] 28,45 [1.12] 1,52 [0.06] 4,06 [0.16] 9,53 [0.375] NA 1/4-28 UNF x
0.25 in deep
25 29,97 [1.18] 49,78 [1.96] 29,97 [1.18] 44,96 [1.77] 3,05 [0.12] 7,62 [0.30] 19,05 [0.75] NA 1/4-28 UNF x
0.25 in deep
50 40,39 [1.59] 61,98 [2.44] 40,39 [1.59] 64,0 [2.52] 4,57 [0.18] 4,83 [0.19] 38,1 [1.5] NA 3/8-24 UNF x
0.38 in deep
100 57,15 [2.25] 81,03 [3.19] 57,15 [2.25] 85,85 [3.38] 6,35 [0.25] 17,53 [0.69] 38,1 [1.5] NA 3/8-24 UNF x
0.38 in deep
250 90,68 [3.57] 112,78 [4.44] 90,68 [3.57] 135,89 [5.35] 6,35 [0.25] 43,18 [1.7] 38,1 [1.5] 1/4-28 3/4-16 UNF x
0.75 in deep
500 128,27 [5.05] 163,58 [6.44] 128,27 [5.05] 192,28 [7.57] 6,35 [0.25] 66,04 [2.6] 38,1 [1.5] 1/4-28 3/4-16 UNF x
0.75 in deep
1000 181,36 [7.14] 214,38 [8.44] 181,36 [7.14] 264,41 6,35 [0.25] 101,6 [4.0] 38,1 [1.5] 3/8-16 1-12 UNF x
[10.41] 1.0 in deep

Warranty. Honeywell warrants goods of its manufacture as being


free of defective materials and faulty workmanship. Honeywell’s WARNING
standard product warranty applies unless agreed to otherwise by PERSONAL INJURY
Honeywell in writing; please refer to your order acknowledgement • DO NOT USE these products as safety or emergency
or consult your local sales office for specific warranty details. If stop devices or in any other application where failure of
warranted goods are returned to Honeywell during the period of the product could result in personal injury.
coverage, Honeywell will repair or replace, at its option, without
Failure to comply with these instructions could result in
charge those items it finds defective. The foregoing is buyer’s sole
death or serious injury.
remedy and is in lieu of all warranties, expressed or implied,
including those of merchantability and fitness for a particular
purpose. In no event shall Honeywell be liable for consequential,
WARNING
special, or indirect damages. MISUSE OF DOCUMENTATION
While we provide application assistance personally, through our
• The information presented in this catalogue is for
literature and the Honeywell web site, it is up to the customer to
reference only. DO NOT USE this document as product
determine the suitability of the product in the application.
installation information.
• Complete installation, operation and maintenance
Specifications may change without notice. The information we information is provided in the instructions supplied with
supply is believed to be accurate and reliable as of this printing. each product.
However, we assume no responsibility for its use.
Failure to comply with these instructions could result in
For more information about Sensing and Control products, visit www. death or serious injury.
honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008648-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model D
Thru-Hole Load Cell
DESCRIPTION
The Model D Donut Shaped Load Cell features a smooth thru- scale non-linearity and hysteresis of ±0.5 % F.S., respectively.
hole design often ideal for applications which require the load These models are used in compression applications and
structure to pass directly through the cell. Such applications are available in multiple hole and frame sizes. For optimum
include bolt force measurements, clamping forces, and performance, these cells must be mounted between load
monitoring overloads. Load ranges as low as 150 grams and as surfaces which are flat and parallel. The Model D miniature load
great as 30,000 pounds can be measured within a maximum full cell is designed to have a minimum thickness.

FEATURES
• 150 g to 30000 lb
• Thru-hole design
• Flexible configuration

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model D

PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS


Characteristic Measure Characteristic Measure
Load ranges 8
150 g to 30000 lb Maximum allowable load 150 % FS1
Accuracy 1% Weight note4
Linearity (max.) ±0.5 % full scale Material Stainless steel
Hysteresis (max.) ±0.5 % full scale Deflection full scale note4
Non-repeatability (max.) ±0.1 % full scale Natural frequency note4
Output (tolerance)
20 mV/V (nominal)
150 g to 1000 g
RANGE CODES
Output (tolerance)
2 mV/V (nominal) Range Available ranges Range Available ranges
5 lb to 30000 lb
Code Code
Operation Compression
AL 150 g CR 500 lb
Resolution Infinite
AN 250 g CV 1000 lb
AP 500 g DL 2000 lb
ENVIRONMENTAL SPECIFICATIONS
AR 1000 g DN 3000 lb
Characteristic Measure AT 5 lb DR 5000 lb
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] AV 10 lb DT 7500 lb
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] BL 25 lb DV 10000 lb
Temperature effect, zero 0.01 % full scale/°F BN 50 lb EJ 15000 lb
150 g to 1000 g BR 100 lb EL 20000 lb
Temperature effect, zero 0.005 % full scale/°F CN 250 lb EN 30000 lb
5 lb to 30000 lb
Temperature effect, span 0.02 % full scale/°F
150 g to 1000 g WIRING CODES
Temperature effect, span 0.010 % full scale/°F Wire
5 lb to 30000 lb Red (+) excitation
Black (-) excitation
ELECTRICAL SPECIFICATIONS Green (-) output

Characteristic Measure White (+) output

Strain gage type Semiconductor


150 g to 1000 g TYPICAL SYSTEM DIAGRAM
Strain gage type Bonded foil
5 lb to 30000 lb
Excitation (calibration) 5 Vdc
150 g to 1000 g
Excitation (calibration) 10 Vdc
5 lb to 30000 lb
Insulation resistance 5000 mOhm @ 50 Vdc
Bridge resistance (toler- 500 ohm (nominal)
ance)150 g to 1000 g
Bridge resistance (toler- 350 ohm (nominal)
ance) 5 lb to 30000 lb
Zero balance (tolerance) ±1 % of full scale
Shunt calibration data Included
Electrical termination (std) Teflon cable (5 ft)

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Thru-Hole Load Cell

MOUNTING DIMENSIONS

Ranges Order code ØOD mm ØID mm [in] H1 mm [in] H2 mm [in] H3 mm [in] ØD1 mm ØD2 mm
[in] [in] [in]
150, 250, BL912 12,7 [0.50] 2,54 [0.10] 3,81 [0.15] 0,51 [0.02] 0,25 5,08 [0.20] 11,43 [0.45]
500, 1000 g [0.01]
5, 10 lb BL912 25,4 [1.00] 5,08 [0.20] 7,11 [0.28] 0,76 [0.03] 0,51 [0.02] 6,60 [0.26] 21,59 [0.85]
25, 50, 100 BL912 25,4 [1.00] 5,08 [0.20] 7,11 [0.28] 0,76 [0.03] 0,51 [0.02] 9,14 [0.36] 21,59 [0.85]
lb
Frame A BL913 38,1 [1.50] See below 12,7 [0.50] 1,27 [0.05] 0,76 [0.03] 12,7 [0.50] 30,73 [1.21]
(100 to 2000
lb)
Frame B BL914 50,8 [2.00] See below 16,00 [0.63] 1,52 [0.06] 0,76 [0.03] 22,53 42,67 [1.68]
(250 to [0.88]
10000 lb)
Frame C BL915 76,2 [3.00] See below 25,4 [1.0] 2,03 [0.08] 0,76 [0.03] 43,18 [1.70] 62,48 [2.46]
(2000 to
30000 lb)
Listed above are four different order codes; BL912, BL913, BL914, BL915. The frame size selection guide below indicates that with a single shell size
(outside diameter), different thru holes are available for order codes BL913, BL914 and BL915 (frames A, B, and C, respectively). To choose a product,
first select the desired load capacity. Then, if applicable, choose the desired inner diameter and an appropriate frame size. For example, a 250 lb load
cell is available in the small frame size (A) with a nominal thru hole size of 1/8 in (P), 3/16 in (Q), 1/4 in (R) or 3/8 in (S) diameter, or in the medium frame
size (B) with thru hole sizes up to 5/8 in (V). We manufacture the actual hole dimensions to provide some clearance; for example the 1/8 in (P) dimen-
sion, the actual dimension is 0.128 in.

Hole letters P Q R S T V W Y Z
ØID (nom) 1/8 in 3/16 in 1/4 in 3/8 in 1/2 in 5/8 in 3/4 in 1 in 1 1/4 in
ØID (act) 0.128 in 0.193 in 0.266 in 0.391 in 0.532 in 0.656 in 0.781 in 1.032 in 1.281 in
100 lb A A A A NA NA NA NA NA
250 lb A or B A or B A or B A or B B B NA NA NA
500 lb A or B A or B A or B A or B B B NA NA NA
1000 lb A or B A or B A or B B B B NA NA NA
2000 lb A, B, or C A, B, or C A, B, or C B or C B or C B or C C C C
3000 lb B or C B or C B or C B or C B or C C C C C
5000 lb B or C B or C B or C B or C B or C C C C C
7500 lb B or C B or C B or C B or C B or C C C C C
10000 lb B or C B or C B or C B or C B or C C C C C
15000 lb C C C C C C C C C
20000 lb C C C C C C C C C
30000 lb C C C C C C C C C

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model D Thru-Hole Load Cell
OPTION CODES Warranty. Honeywell warrants goods of its manufacture as
Many range/option combinations are available in being free of defective materials and faulty workmanship.
our quick-ship and fast-track manufacture pro- Honeywell’s standard product warranty applies unless agreed
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
Load ranges 150 g, 250 g, 500 g, 1000 g; 5, 10, 25, 50, 100, 250,
500, 1000, 2000, 3000, 5000, 7500, 10000, 15000, specific warranty details. If warranted goods are returned to
20000, 30000 lb Honeywell during the period of coverage, Honeywell will repair
Temperature 1a. 60 °F to 160 °F 1f. 70 °F to 250 °F or replace, at its option, without charge those items it finds
compensa- 1b. 30 °F to 130 °F 1g. 70 °F to 325 °F3 defective. The foregoing is buyer’s sole remedy and is in lieu
tion 1c. 0 °F to 185 °F 1h. 70 °F to 400 °F3
1d. -20 °F to 130 °F 1i. -65 °F to 250 °F of all warranties, expressed or implied, including those of
1e. -20 °F to 200 °F merchantability and fitness for a particular purpose. In no
Internal am- 2u. Unamplified, mV/V output event shall Honeywell be liable for consequential, special, or
plifiers indirect damages.
Electrical 6e. Integral cable: Teflon (5 ft)
While we provide application assistance personally, through our
termination 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max.
250 °F) on end of cable literature and the Honeywell web site, it is up to the customer to
6v. Phoenix connector on end of cable determine the suitability of the product in the application.
6i. Integral underwater cable6
Electrical 15d. Connector on end of cable5 Specifications may change without notice. The information we
connector supply is believed to be accurate and reliable as of this printing.
orientation However, we assume no responsibility for its use.
Load direc- 30a. Positive in compression, compression testing
tion only For more information about Sensing and Control products, visit
30c. Negative in compression, compression testing www.honeywell.com/sensing or call +1-815-235-6847
only Email inquiries to info.sc@honeywell.com
Shock and 44a. Shock and vibration resistance
vibration
WARNING
Interfaces 53s. Signature calibration5 (Inline)
53t. TEDS IEEE 1451.4 module7 (Inline) PERSONAL INJURY
• DO NOT USE these products as safety or emergency
NOTES stop devices or in any other application where failure of
1. Allowable maximum loads – maximum load to be applied without
the product could result in personal injury.
damage.2 Loads described allow for 100 % full scale axial loading Failure to comply with these instructions could result in
with the bending loads specified. Torque loading maximum is with-
out axial or other load. For any other combination consult factory.
death or serious injury.
2. Without damage – loading to this level will not cause excessive
zero shift of performance degradation. The user must consider
fatigue life for long term use and structural integrity. All structur-
WARNING
ally critical applications (overhead loading, etc.) should always be MISUSE OF DOCUMENTATION
designed with safety redundant load paths.
3. Only for ranges greater than or equal to 5 lb. • The information presented in this catalogue is for
4. Varies by features selected, consult factory. reference only. DO NOT USE this document as product
5. Be sure to specify electrical termination option 6a or 6v in option
code. For custom connector, consult factory.
installation information.
6. Dimension “H1” may increase with this option, consult factory. Not • Complete installation, operation and maintenance
available with option 1c, 1e, 1f, 1g, 1h, or 1i. information is provided in the instructions supplied with
7. Only available with integral cable units.
8. This unit calibrated to Imperial (non-Metric) units.
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847 008649-2-EN IL50 GLO 
December 2008
www.honeywell.com/sensing Copyright © 2008 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model TH
Thru-Hole Load Cell
DESCRIPTION
Model TH Donut Shaped Load Cell features a smooth thru- applications. For optimum performance, this load cell must be
hole design for use in applications which require the load mounted between load surfaces which are flat and parallel. The
structure to pass through the cell. Such applications include Model TH Donut Shaped Load Cell is designed to provide the
bolt force measurement, post or leg mount, and rolling mill customer with an internal hole diameter which is large relative
systems. Load ranges as low as 15,000 pounds and as great to the outside diameter. The Model TH is a small size, high
as 200,000 pounds can be measured within a maximum full capacity load cell.
scale non-linearity of ±0.25. This model is used in compression

FEATURES
• 15000 lb to 200000 lb range
• Thru-hole design
• Compact column construction
• mV/V output
• 0.25 % linearity

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model TH

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range codes Range
Load ranges 3
15000 lb to 200000 lb EJ 15000 lb
Accuracy 0.5 % EL 20000 lb
Linearity (max.) ±0.25 % full scale EN 30000 lb
Hysteresis (max.) ±0.25 % full scale
EP 50000 lb
Non-repeatability (max.) ± 0.1 % full scale
ER 75000 lb
Output (tolerance) 2 mV/V (nominal)
ET 100000 lb
Operation Compression
FJ 150000 lb
Resolution Infinite
FL 200000 lb

ENVIRONMENTAL SPECIFICATIONS
DEFLECTIONS AND RINGING FREQUENCIES
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F] Capacity (lb) Deflection at Ringing fre- Weight kg
full scale mm quency (kHz) [lb]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] [in]
Temperature effect, zero 0.005 % full scale/°F 15000 0,025 [0.001] 35 0,18 [0.4]
Temperature effect, span 0.005 % full scale/°F 20000 0,025 [0.001] 35 0,18 [0.4]
30000 0,051 [0.002] 17 0,45 [1.0]
50000 0,051 [0.002] 17 0,45 [1.0]
ELECTRICAL SPECIFICATIONS
75000 0,076 [0.003] 14 0,90 [2.0]
Characteristic Measure
100000 0,076 [0.003] 14 0,90 [2.0]
Strain gage type Bonded foil
150000 0,152 [0.006] 12 1,13 [2.5]
Excitation (calibration) 10 Vdc
200000 0,102 [0.004] 10 2,72 [6]
Insulation resistance 5,000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Zero balance ±1 % full scale
Electrical termination (std) Teflon cable (5 ft)

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150 % FS1
Weight See table
Case material Stainless steel
Deflection full scale See table
Natural frequency See table

WIRING CODES
Cable Unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Thru-Hole Load Cell

MOUNTING DIMENSIONS
Ranges (lb) H mm [in] OD mm [in] ID mm [in] D2 mm [in] D3 mm [in]
15000, 20000 38,1 [1.50] 38,1 [1.50] 19,3 [0.76] 26,92 [1.06] 29,21 [1.15]
30000, 50000 50,8 [ [2.00] 50,8 [ [2.00] 25,65 [1.01] 38,1 [1.50] 38,1 [1.50]
75000, 100000 63,5 [2.50] 63,5 [2.50] 32,60 [1.26] 47,75 [1.88] 47,75 [1.88]
150000 76,2 [3.00] 76,2 [3.00] 38,35 [1.51] 58,67 [2.31] 61,97 [2.44]
200000 88,9 [3.50] 88,9 [3.50] 44,70 [1.76] 69,85 [2.75] 88,9 [3.50]

OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load ranges 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F
compensa- 1b. 30 °F to 130 °F 1h. 70 °F to 400 °F
tion 1c. 0 °F to 185 °F 1i. -65 °F to 250 °F
1d. -20 °F to 130 °F 1j. 0 °C to 50 °C
1e. -20 °F to 200 °F 1k. -20 °C to 85 °C
1f. 70 °F to 250 °F 1m. -25 °C to 110 °C
Internal am- 2u. Unamplified, mV/V output
plifiers
Electrical 6a. Bendix PTIH-10-6P 6h. Integral cable:
termination (or equivalent), 6-pin Silicone
(max. 250 °F) 6i. Integral underwater
6b. MS connector cable
MS3102E-14S- 6j. 1/2-14 conduit fitting
6P (mates with with 5 ft of 4 conduc-
MS3106E-14S-6S) tor PVC cable
(max. 160 °F)4 6q. Integral cable: Poly-
6e. Integral cable: Teflon urethane
(5 ft range) 6v. Phoenix connector
6f. Integral cable: PVC on end of cable
6g. Integral cable: Neo- 15d. Connector on end
prene of cable
Shunt 8a. Precision internal resistor
calibration
Special 9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
calibration 9b. 20 point (10 up/10 down) 10 % increments
@ 70 °F
9c. ASTM E-74 calibration
30a. Positive in compression, compression testing
only
30c. Negative in compression, compression testing
only
Bridge type 31a. Dual bridge
Bridge 12b. 5000 ohm (foil)
resistance
Electrical 15a. Horizontal electrical exit port orientation
connector 15b. Vertical electrical exit port orientation
orientation 15c. Radial electrical exit port orientation
15d. Connector on end of cable
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration
53t. TEDS IEEE 1451.4 module
Honeywell • Sensing and Control 3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model TH Thru-Hole Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – maximum load to be applied without
damage.2 Honeywell’s standard product warranty applies unless agreed
2. Without damage - loading to this level will not cause excessive zero to otherwise by Honeywell in writing; please refer to your
shift or performance degradation. The user must consider fatigue
life for long-term use and structural integrity. All structurally critical order acknowledgement or consult your local sales office for
applications (overhead loading, etc.) should always be designed specific warranty details. If warranted goods are returned to
with safety redundant load paths.
Honeywell during the period of coverage, Honeywell will repair
3. This unit calibrated to Imperial (non-Metric) units.
4. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008650-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3719
Bolt and Engine Mount Force Sensor
DESCRIPTION
The bolt force sensor is a unique transducer which is essentially The beveled hole in this washer, which always faces away from
a hollow-compression strain gage load cell. It is designed to be the sensor, provides clearance for the bolt head radius. When
used with most strain gage indicators. The bolt force sensor is a torque wrench is used, a torque vs. clamp force curve can be
a three-piece assembly consisting of: 1. a large hardened and generated. The 3719 bolt force sensor is designed for use in
ground flat washer with one side beveled, 2. the sensor, and 3. a fastener testing where the compression loading of the sensor
small hardened and ground washer. is induced by the tensile loading of the fastener. The bolt force
sensor must be used with the size fastener for which it was
The three pieces are assembled for various applications. The
designed.
large washer isolates the sensor from the force application tool.

FEATURES
• Compact
• High output
• Standard models for bolts size no. 6 thru 2 in and
up to 20 mm
• Sensor and washers - carpenter 440C stainless steel
• Sensitive to neither bolt nor nut-applied torque

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3719
PERFORMANCE SPECIFICATIONS TYPICAL SYSTEM DIAGRAM
Characteristic Measure
Load range 1
1200 lb to 300000 lb
Non-linearity - ranges up to
±3.0 % of rated output
25K lb (67K N)
Non-linearity - ranges 30K
±4.0 % of rated output
lb and up (102K N)
Hysteresis
±5.0 % of rated output
ranges up to 25K lb (67K N)
Hysteresis - ranges 30K lb
±7.0 % of rated output
and up (102K N)
Repeatability ±0.10 % of rated output
±2 mV/V to 3.5 mV/V depending on size
Output @ rated capacity
(nominal)
Resolution Infinite
Standard calibration Compression

ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero ±0.01 % of full scale/°F
ranges up to 12K lb
Temperature effect, zero ±0.007 % of full scale/°F
ranges 18K lb and up
Temperature effect, output ±0.02 % of reading/°F
ranges up to 12K lb
Temperature effect, output ±0.0035 % of reading/°F
ranges 18K lb and up

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Excitation (maximum) 10 Vdc or Vac RMS
Insulation resistance, > 5000 mOhm @ 50 Vdc
bridge case
Bridge resistance 350 ohm
(tolerance)
Number of bridges 1
Zero balance ±1.0

MECHANICAL SPECIFICATIONS
Characteristic Measure
Static overload capacity 150 % of nominal capacity

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Bolt and Engine Mount Force Sensor
MOUNTING DIMENSIONS
Model Bolt size Capacity lb C in ØD in ØA in ØB in T in
3719-138 No. 6 1200 0.330 0.140 0.42 0.250 0.040
3719-164 No. 8 1800 0.330 0.166 0.47 0.300 0.040
3719-190 No. 10 2400 0.330 0.192 0.52 0.350 0.040
3719-250 1/4 5000 0.370 0.262 0.65 0.470 0.060
3719-312 5/16 7000 0.495 0.326 0.78 0.550 0.060
3719-375 3/8 10000 0.495 0.396 0.80 0.639 0.060
3719-437 7/16 12000 0.495 0.454 0.95 0.720 0.060
3719-500 1/2 20000 0.660 0.517 1.14 0.910 0.080
3719-562 9/16 25000 0.660 0.580 1.23 0.990 0.080
3719-625 5/8 30000 0.660 0.644 1.35 1.150 0.080
3719-750 3/4 45000 0.815 0.770 1.62 1.350 0.095
3719-875 7/8 60000 0.815 0.897 1.72 1.600 0.095
3719-1000 1 90000 0.815 1.024 2.00 1.800 0.095
3719-1125 1 1/8 80000 1.065 1.151 2.20 1.900 0.095
3719-1250 1 1/4 125000 1.125 1.279 2.40 2.250 0.125
3719-1500 1 1/2 190000 1.125 1.533 2.80 2.600 0.125
3719-1750 1 3/4 260000 1.300 1.787 3.20 3.000 0.150
3719-2000 2 300000 1.650 2.041 3.60 3.500 0.200
3719-6MM 6 mm 17000* 9,40* 6,0* 16,3* 10,7* 1,5*
3719-7MM 7 mm 27000* 12,57* 7,1* 16,8* 12,2* 1,5*
3719-8MM 8 mm 31000* 12,57* 8,3* 19,8* 14,5* 1,5*
3719-9MM 9 mm 36000* 12,57* 9,0* 20,3* 15,2* 1,5*
3719-10MM 10 mm 46000* 12,57* 10,1* 20,3* 16,2* 1,5*
3719-12MM 12 mm 67000* 15,75* 12,0* 27,9 22,1* 1,5*
3719-14MM 14 mm 102000* 16,76* 14,0* 31,8* 25,9* 2,0*
3719-15MM 15 mm 125000* 16,76* 15,5* 32,5* 26,4* 2,0*
3719-16MM 16 mm 135000 16,76* 16,1* 34,3* 29,2* 2,0*
3719-18MM 18 mm 156000 19,94* 18,1* 36,8* 31,8* 2,0*
3719-20MM 20 mm 220000 20,70* 20,1* 43,2* 36,8* 2,4*

* Capacities in Newtons, * Dimensions in millimeters

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3719 Bolt and Engine Mount Force Sensor
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. This unit calibrated to Imperial (non-Metric) units.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

Find out more


WARNING
Honeywell serves its customers MISUSE OF DOCUMENTATION
through a worldwide network of • The information presented in this catalogue is for
reference only. DO NOT USE this document as product
sales offices, representatives
installation information.
and distributors. For application
• Complete installation, operation and maintenance
assistance, current specifica- information is provided in the instructions supplied with
tions, pricing or name of the each product.
nearest Authorized Distributor, Failure to comply with these instructions could result in
contact your local sales office. death or serious injury.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 008653-2-EN IL50 GLO 
March 2009
www.honeywell.com Copyright © 2009 Honeywell International Inc. All rights reserved.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3663
Pedal Pressure Load Cell
DESCRIPTION
The pedal pressure sensor mounts directly to the brake pedal force measurements by the automotive industry, finds many
with its own mounting clamp. Load applied up to 1/2 inch off production applications. It adapts to any of the pedal or bar
center, produces less than a 0.5% error. Standard capacity operated devices used in all production facilities.
is 300 lbs. This load cell, which is used for brake pedal

FEATURES
• 50 lb, 100 lb, 200 lb, and 300 lb load capacity
• Low off-center loading error
• Easy mounting
• Rugged load surface
• Integral cable
• Compact size

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3663

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Codes Range
Load range 50, 100, 200, 300 lb BN 50 lb
Non-linearity ±0.25 % of rated output BR 100 lb
Hysteresis ±0.1 % of rated output CL 200 lb
Repeatability ±0.1 % of rated output CP 300 lb
Output @ rated capacity 2 mV/V (nominal)
Operation Tension/compression MOUNTING DIMENSIONS
Resolution Infinite
1 3/32

Standard calibration Tension (+) and compression (-)

2.0 DIA.

ENVIRONMENTAL SPECIFICATIONS 1 5/8 TWO ADJUSTABLE

Characteristic Measure BRAKE PEDAL


CLAMPS
FURNISHED
PAD
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
4 CONDUCTOR CABLE-8 FT.
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero ±0.003 % of rated output/°F
Temperature effect, output ±0.003 % of reading/°F RECEP.
PT06W-12-10P

TYPICAL SYSTEM DIAGRAM


ELECTRICAL SPECIFICATIONS
In-Line Amplifiers Customer Supplied
Characteristic Measure (Used with unamplified units only) Chart Recorder
Strain gage type Foil Alarm Panel
Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Excitation (maximum) 20 Vdc or Vac RMS +/-5 VDC Computer
UV
Insulation resistance > 5000 mOhm @ 50 Vdc UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Bridge resistance (toler- 350 ohm U3W 4-20mA (3 wire)
ance) U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Zero balance ±2.0 % DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
Electrical termination PT06W-12-10P DV10 0 +/- 10 VDC (3 wire)

Honeywell
MECHANICAL SPECIFICATIONS In-Line Amplifier
Output Input
Serial Number

Characteristic Measure
Static overload capacity 150 % of nominal capacity Display Units
Safe overload rating 150 % of nominal capacity SC500 SC1000 SC2000
SC2001 SC3004
GM NK HH
7541 7558 7561-PSD
MODEL 3663

2003.1 lb.
L1 L2 L3 L4
VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

Mating Connectors & Cables

023-LW181-023-LF Mating Connector


7220-109-XX** Mating connector & 4 conductor cable

** XX represents length in feet 20ft maximum

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3663 Pedal Pressure Load Cell
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008676-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3419
Seat Belt Load Cell
DESCRIPTION
The seat belt sensor’s design and calibration method essentially
make it independent of belt thickness, which may change under
load. It provides excellent repeatability without the need for the
extensive belt wrap.

FEATURES
• Up to .1 in of belt thickness
• Small size
• Installs without “threading”
• Low sensitivity to belt thickness change

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 3419

PERFORMANCE SPECIFICATIONS MOUNTING DIMENSIONS


Characteristic Measure 6 FT 4 CONDUCTOR
CABLE
1.0
Load range 3500 lb
Non-linearity ±2 % of rated output PIGTAILS

Hysteresis ±4 % of rated output 2.0

Repeatability ±1.0 % of rated output 3-3/32

Output @ rated capacity 2 mV/V (nominal)


Operation Tension/compression
Resolution Infinite
HINGE POINT FOR
BELT INSTALLATION REMOVABLE PIN
Standard calibration Tension (+) and compression (-) IS REINSERTED
& REMOVAL
BEFORE CLOSING

ENVIRONMENTAL SPECIFICATIONS 0.10 MAX


BELT THICKNESS
Characteristic Measure
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]
2.0
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero ±0.003 % of rated output/°F
Temperature effect, output ±0.003 % of reading/°F TYPICAL SYSTEM DIAGRAM

In-Line Amplifiers Customer Supplied


(Used with unamplified units only) Chart Recorder
ELECTRICAL SPECIFICATIONS Alarm Panel
Amplifier Output
Characteristic Measure Universal In-Line Amplifiers Data Acquisition
UV +/-5 VDC Computer
Strain gage type Foil UV-10 +/-10 VDC PLC
UBP 0 +/-5 VDC
Excitation (maximum) 20 Vdc or Vac RMS U3W 4-20mA (3 wire)
U2W 4-20mA (2 wire)
Insulation resistance > 5000 mOhm @ 50 Vdc DIN rail Mount In-Line Amplifiers
Bridge resistance (toler- 350 ohm DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
ance) DV10 0 +/- 10 VDC (3 wire)
Zero balance ±2.0 %
Honeywell
Electrical termination 6 ft of four-conductor cable In-Line Amplifier
Output Input
Serial Number

Display Units
MECHANICAL SPECIFICATIONS
SC500 SC1000 SC2000
Characteristic Measure SC2001 SC3004
Static overload capacity 150 % of nominal capacity GM NK HH
MODEL 3419 7541 7558 7561-PSD
Weight 8 oz
Band thickness 2,54 mm [0.10 in]
2003.1 lb.
Band width 50,8 mm [2.0 in] L1 L2 L3 L4
VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

RANGE CODES
Mating Connectors & Cables
Wire
023-LW181-023-LF Mating Connector
Red (+) excitation 7205-76-XX* Mating connector & 6 conductor cable
(unamplified unit with sense leads but not shunt cal)
Black (-) excitation 7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
Green (+) output 7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541)
White (-) output 7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)

* XX represents length in feet 100ft maximum


** XX represents length in feet 20ft maximum

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 3419 Seat Belt Load Cell
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008677-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 6443
X-Y Force Sensor
DESCRIPTION
The X-Y force sensor is constructed of two strain gage bridges, strength and to minimize crosstalk between the two transducers.
mounted at 90º, isolated by a flexure system. The complete This unique sensor has excellent linearity characteristics and
two-component system, including flexures, is machined from maximum structure life.
one specially prepared metal billet to provide unusual structure

FEATURES
• Compact size
• 0.1 % linearity and hysteresis, respectively
• Simultaneous dual-axis readings
• Minimal crosstalk

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model 6443

PERFORMANCE SPECIFICATIONS MOUNTING DIMENSIONS


RECEP.
Characteristic Measure MS-3102E-14S-5P (2)
13/32 4 HOLES
Load range 6443 (1000 lb X, 500 lb Y) EQUALLY SPACED
2-21/32
1.062
6443-105 (2000 lb X, 500 lb Y)
6443-106 (1500 lb X, 500 lb Y)
Non-linearity ±0.1 % of rated output
2-1/16 TYP.
Hysteresis ±0.1 % of rated output 7.0 DIA. 2.50 DIA.
0.75
BRG
BOTH ENDS BORE
Repeatability ±0.05 % of rated output 45
Output @ rated capacity 2 mV/V ±0.25 % (nominal)
6.25 DIA. B.C.
7/64 MAX.
Operation Tension/compression 1/8
1.0
Resolution Infinite
Standard calibration Tension (+) and compression (-)1 TYPICAL SYSTEM DIAGRAM
In-Line Amplifiers Customer Supplied
ENVIRONMENTAL SPECIFICATIONS (Used with unamplified units only) Chart Recorder
Alarm Panel
Characteristic Measure Amplifier Output
Universal In-Line Amplifiers Data Acquisition
Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F] UV +/-5 VDC Computer
UV-10 +/-10 VDC PLC
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F] UBP 0 +/-5 VDC
U3W 4-20mA (3 wire)
Temperature effect, zero ±0.002 % of rated output/°F U2W 4-20mA (2 wire)
Temperature effect, output ±0.002 % of reading/°F DIN rail Mount In-Line Amplifiers
DV-05 0 +/- 5 VDC (3 wire) Power Supply
DA-05 4-20mA (3 wire)
DV10 0 +/- 10 VDC (3 wire)
ELECTRICAL SPECIFICATIONS
Honeywell
Characteristic Measure In-Line Amplifier
Output Input
Serial Number

Strain gage type Foil


Excitation (maximum) 20 Vdc or Vac RMS Display Units
Insulation resistance > 5000 mOhm @ 50 Vdc SC500 SC1000 SC2000
Bridge resistance (toler- 350 ohm SC2001 SC3004
MODEL X-Y FORCE GM NK HH
ance) 7541 7558 7561-PSD
Crosstalk 1 % of full scale
Zero balance ±1.0 %
2003.1 lb.
Electrical termination MS-3102E-14S-5P (2) OR L1 L2 L3 L4
VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT

MECHANICAL SPECIFICATIONS
Mating Connectors & Cables
Characteristic Measure
064-LW13621 Mating connector
Safe overload capacity 150 % of rated capacity
7200-76-XX* Mating connector and six conductor cable
Material Carbon steel (unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
(unamplified sensor without sense leads)
RANGE CODES 7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
Wire 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
Red (+) excitation
* XX represents length in feet 100ft maximum
Black (-) excitation ** XX represents length in feet 20ft maximum

Green (+) output


White (-) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Models 6443 X-Y Force Sensor
NOTES Warranty. Honeywell warrants goods of its manufacture as
1. Standard calibration for tension/compression load cells is in ten- being free of defective materials and faulty workmanship.
sion only.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008836-1-EN IL50 GLO 
+1-815-235-6847 June 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MBH
Minigram Beam Load Cell
DESCRIPTION
Models MBH Minigram Beam Load Cells are engineered to dimensions allow easy unit integration into existing systems.
measure very low bending forces and still achieve an impressive Model MBH uses foil gages and is available for load ranges from
0.1% full scale non-linearity and hysteresis. Built-in overload 150 grams to 10 pounds.
stops are incorporated to provide additional reliability. Miniature

FEATURES
• 150 g to 10 lb range
• Miniature size
• 0.1 % linearity
• Small diameter
• Integral cable
• Calibrated in compression only

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MBH

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Codes Range
Load ranges 4
150, 250, 500, 1000 g; 5, 10 lb AL 150 g
Linearity (max.) ±0.1 % full scale AN 250 g
Hysteresis (max.) ±0.1 % full scale AP 500 g
Non-repeatability (max.) ±0.03 % full scale AR 1000 g
Output (tolerance) 2 mV/V (nominal) AT 5 lb
Operation Tension/compression1
AV 10 lb
Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS OPTION CODES


Characteristic Measure Many range/option combinations are available
Temperature, operating -18 °C to 71 °C [0 °F to 160 °F] in our quick-ship and fast-track manufacture
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Temperature, storage -73 °C to 93 °C [-100 °F to 200 °F]
Load range 150, 250, 500, 1000 g; 5, 10 lb
Temperature effect, zero 0.005 % full scale/°F
Temperature 1a. 60 °F to 160 °F
Temperature effect, span 0.005 % full scale/°F
compensation 1b. 30 °F to 130 °F
1c. 0 °F to 185 °F

ELECTRICAL SPECIFICATIONS Internal 2u. Unamplified, mV/V output


amplifiers
Characteristic Measure
Electrical 6e. Integral cable: Teflon
Strain gage type Bonded foil termination 6d. Microtec DR-4S-4H four-pin
Excitation (calibration) 5 Vdc Special 9a. 10 point (5 up/5 down) 20 % increments
Insulation resistance 5000 mOhm @ 50 Vdc calibration @ 70 °F
Bridge resistance 350 ohm
Zero balance ±5 % full scale MOUNTING DIMENSIONS
Electrical termination (std) Cable 1,83 m [5 ft]

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 400 % full scale or 20 lb, whichever is
less2
Weight 50 g
Material Aluminum

WIRING CODES
Cable Unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MBH Minigram Beam Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Positive in compression; calibrated in compression only.
2. Allowable maximum loads – maximum load to be applied without Honeywell’s standard product warranty applies unless agreed
damage.3 to otherwise by Honeywell in writing; please refer to your
3. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue order acknowledgement or consult your local sales office for
life for long term use and structural integrity. All structurally critical specific warranty details. If warranted goods are returned to
applications (overhead loading, etc.) should always be designed
Honeywell during the period of coverage, Honeywell will repair
with safety redundant load paths.
4. This unit calibrated to Imperial (non-Metric) units. or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008668-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MBL
Minigram Beam Load Cell
DESCRIPTION
Models MBL Minigram Beam Load Cells are engineered to dimensions allow easy unit integration into existing systems.
measure very low bending forces and still achieve an impressive Model MBL uses semiconductor gages and is available for load
0.1 % full scale non-linearity and hysteresis. Built-in overload ranges from 25 to 1000 grams.
stops are incorporated to provide additional reliability. Miniature

FEATURES
• 25 g to 1000 g
• Miniature size
• 0.1 % linearity
• Small diameter
• Integral cable
• Calibrated in compression only

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MBL

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Codes Range
Load ranges 4
25, 50, 100, 150, 250, 500, 1000 g AH 25 g
Linearity (max.) ±0.1 % full scale AJ 50 g
Hysteresis (max.) ±0.1 % full scale AK 100 g
Non-repeatability (max.) ±0.03 % full scale AL 150 g
Output (tolerance) 20 mV/V (nominal) AN 250 g
Operation Tension/compression1
AP 500 g
Resolution Infinite
AR 1000 g

ENVIRONMENTAL SPECIFICATIONS OPTION CODES


Characteristic Measure Many range/option combinations are available
Temperature, operating -18 °C to 93 °C [0 °F to 200 °F] in our quick-ship and fast-track manufacture
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Temperature, storage -73 °C to 93 °C [-100 °F to 200 °F]
Load range 25, 50, 100, 150, 250, 500, 1000 g
Temperature effect, zero 0.015 % full scale/°F
Temperature 1a. 60 °F to 160 °F
Temperature effect, span 0.02 % full scale/°F
compensation 1b. 30 °F to 130 °F
1c. 0 °F to 185 °F

ELECTRICAL SPECIFICATIONS Internal 2u. Unamplified, mV/V output


amplifiers
Characteristic Measure
Electrical 6e. Integral cable: Teflon
Strain gage type Bonded semiconductor termination 6d. Microtec DR-4S-4H four-pin
Excitation (calibration) 5 Vdc Special 9a. 10 point (5 up/5 down) 20 % increments
Insulation resistance 5000 mOhm @ 50 Vdc calibration @ 70 °F
Bridge resistance 500 ohm
Zero balance ±5 % full scale MOUNTING DIMENSIONS
Electrical termination (std) Cable 1,83 m [5 ft]

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 400 % FS2
Weight 50 g
Material Aluminum

WIRING CODES
Cable Unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output

2 Honeywell • Sensing and Control

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model MBL Minigram Beam Load Cell
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Positive in compression; calibrated in compression only.
2. Allowable maximum loads – maximum load to be applied without Honeywell’s standard product warranty applies unless agreed
damage.3 to otherwise by Honeywell in writing; please refer to your
3. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue order acknowledgement or consult your local sales office for
life for long term use and structural integrity. All structurally critical specific warranty details. If warranted goods are returned to
applications (overhead loading, etc.) should always be designed
Honeywell during the period of coverage, Honeywell will repair
with safety redundant load paths.
4. This unit calibrated to Imperial (non-Metric) units. or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
TYPICAL SYSTEM DIAGRAM of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.

While we provide application assistance personally, through our


literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008667-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LP
Force Sensing Clevis Pin

DESCRIPTION
Model LP load pins are designed to be installed where pins or less steel construction and is available with a standard PTIH-10-
bolts are carrying a load. Applications which involve the use of 6P connector or an optional submersible cable. These
shackle pins, clevis pins and pully shafts are prime examples of rugged clevis pins provide excellent long term stability and reli-
where force sensing clevis pins can provide accurate, real time able operation under severe operating conditions.
monitoring of load forces. The Model LP features welded stain-

FEATURES
• 2000 lb to 200000 lb range
• Up to 1 % accuracy
• All welded stainless steel construction
• Amplified output available
• Intrinsically safe available (2N option only)8
• CE approved9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LP

PERFORMANCE SPECIFICATIONS RANGE CODES


Characteristic Measure Range Available ranges Range Available ranges
Load ranges 10
2000, 3000, 5000, 6000, 10000, 12500, Code Code
20000, 30000, 50000, 75000, 100000, DL 2000 lb EN 30000 lb
125000, 150000, and 200000 lb
DN 3000 lb EP 50000 lb
Linearity (max.) from ±0.5 % full scale (consult factory)
DR 5000 lb ER 75000 lb
Hysteresis from ±0.5 % full scale (consult factory)
DS 6000 lb ET 100000 lb
Non-repeatability ±0.15 % full scale
DV 10000 lb FH 125000 lb
Tolerance on output 1 mV/V nominal
DW 12500 lb FJ 150000 lb
EL 20000 lb FL 200000 lb
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
INSTALLATION
Temperature, operating -54 °C to 93 °C [-65 °F to 250 °F]
Standard uses for clevis pins include tongue and yoke shackles
Temperature, compensated 15 °C to 54 °C [60 °F to 160 °F]
and tension pulleys. Clevis pins are also often ideal for use in web
Temperature effect, zero 0.003 % full scale/°F
tension applications. Consult factory for web tension measurement
Temperature effect, span 0.008 % of load/°F
kits from 200 lb to 500000 lb.

ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Foil
Excitation (calibration) 10 Vdc
Bridge resistance 5000 ohm
Electrical termination (std) PTIH-10-6P
Mating connector (not incl.) PT06A-10-6S or equivalent (AA111)

MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 200 % FS1
Case material 17-4 PH stainless steel

WIRING CODES
Connector Unamplified (Std.)
A (+) excitation
B (+) excitation
C (-) excitation
D (-) excitation
E (-) output
F (+) output

2 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Force Sensing Clevis Pin

INTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2a put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal 0 V to 5 V 0 V to 5 V or ±5 V 0 V to 10 V or 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
@ 45 mA ±10 V @ 45 mA
Input power (voltage) ±15 V or 26 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 9 Vdc to
to 32 Vdc 40 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protec- Yes Yes Yes Yes Yes Yes
tion
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
(std)4 B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return ** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Shunt cal 1 E Case ground E Case ground
F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F Shunt cal 2 F No connection F No connection

Wiring code: cable4,5,6 R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output common* Bl Output common* Bl Output common* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt cal 1 B Shunt cal 1 B Shunt cal 1 B Shunt cal 1
Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

TYPICAL SYSTEM DIAGRAM

Honeywell • Sensing and Control 3


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LP
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://
sensing.honeywell.com/TMsensor-ship for updated listings.
Load ranges 2k, 3k, 5k, 6k, 10k, 12.5k, 15k, 20k, 30k, 50k, 75k, 100k, 125k, 150k, 200k lb
Temperature 1a. 60 °F to 160 °F 1g. 70 °F to 325 °F3
compensation 1b. 30 °F to 130 °F 1i. -65 °F to 250 °F3
1c. 0 °F to 185 °F 1j. 0 °C to 50 °C
1d. -20 °F to 130 °F 1k. -20 °C to 85 °C
1e. -20 °F to 200 °F 1m. -25 °C to 110 °C
1f. 70 °F to 250 °F
Internal 2a. Four-wire 0 Vdc to 5 Vdc output 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe11
amplifiers 2c. 0 Vdc to 5 Vdc output 2t. 0 Vdc to 10 Vdc
2j. 4 mA to 20 mA (three-wire) output 2u. Unamplified, mV/V output
2k. 4 mA to 20 mA (two-wire) output11
Electrical amp 3a. Input/output isolation2
enhancements 3d. Remote buffered shunt calibration
Electrical 6a. Bendix PTIH-10-6P (or equivalent) 6-pin (max. 250 °F) 6h. Integral cable: Silicone
termination 6b. MS connector MS3102E-14S-6P (mates with MS3106E- 6i. Integral underwater cable
14S-6S) (max. 160 °F) 6j. 1/2-14 conduit fitting with 5 ft of four conductor PVC cable
6f. Integral cable: PVC 6q. Molded integral cable: Polyurethane
6g. Integral cable: Neoprene 6v. Phoenix connector at end of cable
15d. Connector on end of cable
Shunt 8a. Precision internal resistor3
calibration
Special 9e. CE mark
calibration 9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
9b. 20 point (10 up/10 down) 10 % increments @ 70 °F
9c. ASTM E-74 calibration
Bridge 12b. 5000 ohm (foil)
resistance
Zero and span 14a. No access to zero and span adjustment
adjustment
Special 30a. Compression only (+) output
calibration 30b. Tension and compression (+,-) output
30c. Compression only (-) output
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration3
53t. TEDS IEEE 1451.4 module7

4 Honeywell • Sensing and Control


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Force Sensing Clevis Pin

MOUNTING DIMENSIONS

Capac- A mm B mm C mm D mm F mm G mm H mm J mm Key mm SRG* N mm


ity lb [in]** [in] [in] [in] [in] [in] [in] [in] [in] [in]
2000, 12,7 12,7 19,05 38,1 101,09 6,35 5,08 6,35 NA 11,89 0,99
3000 [0.500] [0.50] [0.75] [1.50] [3.98] [0.25] [0.20] [0.25] [0.468] [0.039]
5000, 19,05 14,99 25,4 38,1 113,79 7,87 5,08 6,35 3,96 17,88 1,17
6000 [0.750] [0.59] [1.00] [1.50] [4.48] [0.31] [0.20] [0.25] [0.156] [0.704] [0.046]
10000, 25,4 16 [0.63] 25,4 38,1 120,4 12,7 5,08 6,35 5,56 23,88 1,17
12500 [1.00] [1.00] [1.50] [4.74] [0.50] [0.20] [0.25] [0.219] [0.940] [0.046]
15000, 31,75 20,57 35,05 50,8 144,53 16 [0.63] 6,86 6,35 5,56 29,87 1,42
20000 [1.250] [0.81] [1.38] [2.00] [5.69] [0.27] [0.25] [0.219] [1.176] [0.056]
30000 38,1 23,88 41,40 50,8 157,48 16 [0.63] 6,86 6,35 7,14 35,71 1,42
[1.50] [0.94] [1.63] [2.00] [6.20] [0.27] [0.25] [0.281] [1.406] [0.056]

Capac- A mm [in]** B mm [in] C mm [in] D mm [in] F mm [in] G mm [in] H mm [in] J mm [in] Key mm [in]
ity lb
50000 50,8 [2.000] 25,4 [1.00] 50,8 [2.00] 38,1 [1.50] 167,89 [6.61] 19,05 [0.75] 6,76 [0.266] 9,65 [0.38] 7,14 [0.281]
75000 63,5 [2.500] 31,75 [1.25] 63,5 [2.50] 50,8 [2.00] 193,29 [7.61] 19,05 [0.75] 6,76 [0.266] 12,7 [0.50] 7,14 [0.281]
100000 69,85 [2.750] 37,34 [1.47] 69,85 [2.69] 50,8 [2.00] 219,20 [8.63] 25,4 [1.00] 10,31 [0.406] 12,7 [0.50] 10,31 [0.406]
125000 76,2 [3.000] 36,58 [1.44] 76,2 [3.00] 50,8 [2.00] 225,55 [8.88] 25,4 [1.00] 10,31 [0.406] 16 [0.63] 10,31 [0.406]
150000 88,9 [3.500] 44,45 [1.75] 88,9 [3.50] 50,8 [2.00] 263,65 [10.38] 31,75 [1.25] 13,49 [0.531] 16 [0.63] 13,49 [0.531]
200000 101,6 [4.000] 57,15 [2.25] 101,6 [4.00] 50,8 [2.00] 301,75 [11.88] 31,75 [1.25] 13,49 [0.531] 19,05 [0.75] 13,49 [0.531]

*SRG - Snap ring groove diameter


**Tolerance = +0.000 in/-0.002 in

Honeywell • Sensing and Control 5


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model LP Force Sensing Clevis Pin
NOTES Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
1. Allowable maximum loads – Maximum load to be applied without
damage. Honeywell’s standard product warranty applies unless agreed
2. Only available with option 2b or 2c. to otherwise by Honeywell in writing; please refer to your
3. Not available with amplified option.
4. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal order acknowledgement or consult your local sales office for
provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire specific warranty details. If warranted goods are returned to
units) or 80 % (voltage amplified units) of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier Honeywell during the period of coverage, Honeywell will repair
option 2a, 2b, 2c, 2t and 2j. or replace, at its option, without charge those items it finds
5. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
defective. The foregoing is buyer’s sole remedy and is in lieu
W=White; G=Green. Color specifying cable and number or letter
specifying connector. of all warranties, expressed or implied, including those of
6. No mating connector necessary for cable option. merchantability and fitness for a particular purpose. In no
7. Consult factory for TEDS availability with amplified models.
8. Range dependent; consult factory. Termination dependent; consult event shall Honeywell be liable for consequential, special, or
factory. indirect damages.
9. Internal amp and termination dependent; consult factory.
10. This unit calibrated to Imperial (non-Metric) units. While we provide application assistance personally, through our
11. 5000 ohm bridge required.
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.

Specifications may change without notice. The information we


supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit


www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com

WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.

WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.

Sensing and Control


Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
008669-1-EN IL50 GLO 
+1-815-235-6847 May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com