Support document for installation of

new cable for iPASOLINK

3rd System Group


Mobile Wireless Solutions Division
NEC Corporation
1. Power Cable

Page 2 © NEC Corporation 2014 NEC Group Internal Use Only


Summary

▌ Changed points
1. Type of Cable assembly
Before Change: 10/15m x 4 independent cables (iPaso 100E/100/200/400)/ IDU
10/15m x 10 independent cables (iPaso 1000)/ IDU
After Change : 0.45m x 1 Sub-Cable (Consisted by 4 x cables and swage) +
10m x 1 main Cable (supplied in a form of un-cut drum)
(iPaso 100E/100/200/400)/ IDU
0.45m x 1 Sub-Cable (Consisted by 10 x cables and swage) +
10m x 1 main Cable (supplied in a form of un-cut drum)
(iPaso 1000)/ IDU

Main cable shall be cut depending on the length required up to DC-PDB on site.
Main and Sub cables shall be assembled on site (required crimping tool supplied in
the first project).

2. Cable color
Before Change: Red & Blue
After Change : Blue & Black

Page 3 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 100/200/400)
 What to be supplied

1. Sub-cable (Assembled) 1EA/ Site


Cable Sleeve (Unfixed)

Power 1.0sqmm
Connector

2. Main Cable (Drum)


2.08 sqmm (AWG #14)

Drum of Main Power Cable
10m x Number of Site*
* To be supplied in a form of drum (Un‐cut per site)

Page 4 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 100/200/400)
1. Insert the socket contacts into the power connector until they are locked.

2. Measure the length between power source and IDU. Cut the main power
cable with enough length.

Cut Cut

Page 5 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 100/200/400)
3. Remove 5.0mm to 10.0mm of insulation

5.0 to 10.0mm Main power cable

4. Insert the main power cable into connecting point and swage it.

Power
Connector

Page 6 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 100/200/400)
3. Cover the connection point with cable sleeve and heat

Power
Connector

4. Complete

Power
Connector

Page 7 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 1000)
 What to be supplied

1. Sub-cable (Assembled) 1EA/ Site


Cable Sleeve (Unfixed)

Power Sub-cables 1.0sqmm


Connector

0.45m
2. Main Cable (Drum)

5.2161 sqmm (AWG #10)

Drum of Main Power Cable
10m x Number of Site*
* To be supplied in a form of drum (Un‐cut per site)

Page 8 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 1000)
1. Insert the socket contacts into the power connector until they are locked.

2. Measure the length between power source and IDU. Cut the main power
cable with enough length.

Cut Cut

Page 9 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 1000)
3. Remove 5.0mm to 10.0mm of insulation

5.0 to 10.0mm Main power cable

4. Insert the main power cable into connecting point and swage it.

Power
Connector

Page 10 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure (iPaso 1000)
3. Cover the connection point with cable sleeve and heat it.

Power
Connector

4. Complete

Power
Connector

Page 11 © NEC Corporation 2014 NEC Group Internal Use Only


2. IF pig tail cable

Page 12 © NEC Corporation 2014 NEC Group Internal Use Only


Summary

▌ Changed points ODU New configuration

Connection between IDU and IF Cable


In addition to the standard installation material,
NEC shall provide 5m length of IF pig tail cable. 5D-FB IF Cable

This cable is used for connection of IDU and N-Type Connector


5D-FB IF cable. (Male)

ODU Old configuration


Arrestor

N-Type Connector
(Female)

3D-FB
5D-FB IF Cable
IF pig tail cable
Length: 5m
TNC Connector (Male)

iPasolink iPasolink
Arrestor TNC Connector (Male)

Page 13 © NEC Corporation 2014 NEC Group Internal Use Only


Installation Procedure
 What to be supplied

1. 3D-FB IF pig tail cable (5m)

Arrestor
IF cable IF pig tail cable

IDU

Main Earth

1. Follow the installation manual for procedure of connector assembly and cable connection to IDU
2. Lay the IF pig tail cable along the rack with cable tie and fix the other end connector on the cable rack.
3. Connect IF pig tale cable, arrestor and IF cable*.
4. Connect arrestor and main earth with grounding cable, and cover with insulation tape.
* In case connection part must be put outdoor, cover it with self-bonding tape is required for water proof.