Escolar Documentos
Profissional Documentos
Cultura Documentos
1 Cuadro de areas
Area techada por nivel 381.46 m2
# Pisos 6.00
Area total 2,288.78 tonf 121%
2 Metrado de cargas
Tables à Model àStructure Data àMaterial List à Material List by Section
Cortante estatico
Porticos 25.0% 693.20
Albañileria 25.0% 693.20
4 Cortante estatico
VX VY
Story Load Case/Combo
tonf tonf
Story1 SDX Max -445.7635 0.00 -64%
Story1 SDY Max 0.00 -445.7635 -64%
5 Control de Derivas
R= 7.00
Derivas
Derivas
Piso Tipo de Carga Δelástica Deriva inelastica inelásticas
Δ(%)
Story6 SISMO X 0.000282 0.00197 0.20
Story5 SISMO X 0.000321 0.00225 0.22
Story4 SISMO X 0.000334 0.00234 0.23
Story3 SISMO X 0.000282 0.00197 0.20
Story2 SISMO X 9.40E-05 0.00066 0.07
Story1 SISMO X 6.70E-05 0.00047 0.05
R= 7.00
Derivas
Derivas
Piso Tipo de Carga Δelástica Deriva inelastica inelásticas
Δ(%)
Story6 SISMO Y 3.00E-05 0.00021 0.02
Story5 SISMO Y 3.10E-05 0.00022 0.02
Story4 SISMO Y 3.00E-05 0.00021 0.02
Story3 SISMO Y 2.50E-05 0.00018 0.02
Story2 SISMO Y 7.00E-05 0.00049 0.05
Story1 SISMO Y 5.70E-05 0.00040 0.04
6 Resistencia Albañileria
V L t
SENTIDO YY
M1 56.61 4.96 0.23
M2 48.02 3.97 0.23
M3 46.26 3.88 0.23
185.38 M4 34.49 3.29 0.23
VX VY
Story Load Case/Combo
tonf tonf
Story1 SDX Max 107.4669 13.7826
Story1 SDY Max 13.7826 130.0921
8 Escalamiento
VX VY
Load Case/Combo
tonf tonf
estatico -445.76 -445.76
dinámico 107.47 130.09
% -24% -29%
FS 3.7331 3.0839
9 Cortante Diseño
VX VY
Story Load Case/Combo
tonf tonf
Nivel 1 SDX[Diseño] Max 157.9245 48.1557
Nivel 1 SDY[Diseño] Max 48.0854 157.9264
S EN ETABS
losas s/c
L1 0.5
L2 0.5
L3 0.5
L4 0.5
L5 0.5
L6 0.5
Prom 0.5
0.70 0.28
0.70 0.32
0.70 0.33
0.70 0.28
0.70 0.09
0.70 0.07
0.70 0.03
0.70 0.03
0.70 0.03
0.70 0.03
0.70 0.07
0.70 0.06
1.14 4.96
0.91 5.26
0.89 5.18
0.76 4.56
2.94 4.49
1.14 4.21
2.94 0.68
2.94 1.02
2.94 1.59
-35.4%
-35.4%
AREA TOTAL 6,500.0000 5334.1595 m2
# BENEFICIARIOS 3 3 m2
AREA PARCELA 2,166.6667 1,778.0532 m2
PARCELA 3