Differential temperature controller with 4 relays and 4 inputs

General Data
The control unit ST501-LN1KV.04FS is designed for differential controll applications with special error inputs.
The unit works together with resistance sensors (PTC, PT100 or PT1000).
The unit offers beyond the temperature regulation a wide range of other functions.
The outputs can be programmed to different functions (Parameter A90-A93 ).
The inputs can be configured with the parameters A94-A97

°C
1
2

E1 E2 E3 E4

SET F1 F2

Description
key 1: UP
Pressing the the UP-key together with the SET-key invreases the Setpoint value.

key 2: DOWN
Pressing the the DOWN-key together with the SET-key devreases the Setpoint value.
With the DOWN key it is also possible to cancel the alarm buzzer.

key 3: SET
The display normally shows the actual value. When the SET button is pressed , the display changes
SET to show the Control Setpoint.

key 4:
Different functions for this key can be selected by parameters.(see Parameter A85)
F1
The selected value is shown as long as the key is pressed and additional 4seconds.

key 5:
Different functions for this key can be selected by parameters.(see Parameter A86)
F2
The selected value is shown as long as the key is pressed and additional 4seconds.

key 6:
The Stand-By function for this key can be selected by setting the parameter A82. The key has to be
pressed for at least half a second.

ST501-LN1KV.04FS 1
First level (Setpoint Adjustment)
Display of the Set Values

The display normally shows the actual value of the process temperature. When the SET button is pressed ,
SET the display changes to show the Control Setpoint (Desired temperature)

Simultaneously press the SET button with either the UP or DOWN button to increase or decrease
the Setpoint. Please release the UP or DOWN button before releasing the SET button and the new
value is loaded into the non-volatile memory.

Para- Function Adjustable range Standard Customer


meter Setting Setting
S1 Setpoint P4...P5 0,0 °C

LED's
"1" Status of pump contact
"2" Status of control output 1
"3" Status of control output 2

upper fixed setpoint control actvated


lower fixed setpoint control actvated
Alarm

E1 Status of input E1
E2 Status of input E2
E3 Status of input E3
E4 Status of input E4

ST501-LN1KV.04FS 2
Second level (P-level)
Setting of control parameters
In order to prevent accidental or unauthorised changes to the pre-set parameter values, access to the P-
Level has been made difficult.
Simultaneously pressing the UP and DOWN button for about 3 seconds switches the controller to the P-
Level, and allows adjustment of the P parameters. The display now shows P1
To display and adjust the value of P1, press the SET button and the existing value of P1 is displayed.
By simultaneously pressing the SET button and either the UP or DOWN button this value can be increased or
decreased as required. Release the UP or DOWN button before releasing the SET button and the new value
is saved into the non-volatile memory.
Use the UP or DOWN button to select the remaining P-parameters, and these can be adjusted in a similar
manner.

To return to the operating mode: Simultaneously press the UP and DOWN button for aprox. 3 seconds and
the display will again show the process temperature. In any case if no adjustment of the parameters is made
for 30 seconds, the controller will automatically return to the operating mode.

Paramete Functions Adjustable range Standard Customer


r Setting setting
P1 Setpoint 2 -99...+999°C
Delta W -99...+99 K 10 K
P2 Hysteresis K1 0,5...99,9 °K 1,0 °K
P3 Hysteresis K2 0,5...99,9 °K 1,0 °K
P4 Control Range Limitation Minimum Setpoint -99...P5 -99 °C
P5 Control Range Limitation Maximum Setpoint P4...999 °C 999 °C
P19 Keyboard lock 0: Not locked 0
( Setpoint Lock ) 1: Locked
P20 display of actual value sensor F1 - -
P21 actual value correction sensor F1 -20...20,0 K
P22 display of actual value sensor F2
P23 actual value correction sensor F2 -20...20,0 K
P30 Lower Boundary Value for alarm sensor F1 -99...999 °C -99 °C
P31 Upper Boundary Value for alarm sensor F1 -99...999 °C 999 °C
P32 Lower Boundary Value for alarm sensor F2 -99...999 °C -99 °C
P33 Upper Boundary Value for alarm sensor F2 -99...999 °C 999 °C
P34 Hysteresis alarm values ( one-side ) 0,5...99,9 °K 1,0 °K

P35 Lower value for fixed setpoint control on -99...999°C -99°C -10°C
following sensor
(only avtive if differential control)
P36 Upper value for fixed setpoint control on -99...999°C +999°C 99,9°C
following sensor
(only avtive if differential control)

ST501-LN1KV.04FS 3
Second level, P-Parameters
P1: Setpoint 2 or Delta W
Two types of output relay control are available (see A5 for selection method).
The first control variation :
Contacts K1 and K2 are linked together with an adjustable switch separation Delta W (operation with Delta W).
This separation can have either a positive or negative value to provide a leading or trailing second contact. In this
variation the controller can also be used as a three-point controller.

The second control variation


Contacts K1 and K2 are independent of each other and are freely adjustable. (operation with Setpoint 2).
Contact K1 operates at Setpoint 1, and K2 operates at Setpoint 2 and can be set as a limit value.
Note: With PID control of contact K2, both contacts K1 and K2 work towards Setpoint 1

P2/P3: Hysteresis K1/K2


The hysteresis for contact K1 can be either symmetrical about the Setpoint, or to one side of the Setpoint (parameter
A40). If symmetrical hysteresis has been selected, then one half of the total hysteresis is above and half below the
Setpoint.
If one side of Setpoint has been selected, then the total hysteresis is below the Setpoint in the heating mode and above
the Setpoint in the cooling mode (see Figure 4).
Please note that small hysteresis values lead to an increased switching frequency and that the lifetime of the output
relays is decreased correspondingly. In critical cases, the controller can be equipped with semiconductor relays.

P4/P5: Control range limitation - minimum/maximum Setpoint


Upper and lower control range limits can be set for the Setpoint. This prevents the end user from adjusting the controller
to unattainable or dangerous Setpoints.

P19: Keyboard lock


The keyboard lock disables the controller keypad and prevents operator adjustment of the Setpoint.

P20: Actual value sensor F1


This parameter allows to see the actual value, without leaving the programming level

P21: Actual value correction sensor F1


A + or - calibration adjustment can be made to the Actual Value indication. It is effective over the entire measurement
range.

P22: Actual value sensor F2


This parameter allows to see the actual value, without leaving the programming level

P23: Actual value correction sensor F3


A + or - calibration adjustment can be made to the Actual Value indication. It is effective over the entire measurement
range.

P30/P31: Lower/Upper boundary value for alarm sensor F1


the alarm values have an adjustable hysteresis (see P34). It can be set to operate as either a boundary or a range
alarm.

P32/P33: Lower/Upper boundary value for alarm sensor F2


the alarm values have an adjustable hysteresis (see P34). It can be set to operate as either a boundary or a range
alarm.

P34: Hysteresis alarm


The hysteresis for the alarm is allways to one side of the Setpoint.

P35: Lower value for fixed setpoint control on following sensor


IThe differential control is deactvated if the temperature goes below the value set in this parameter.

P35: Upper value for fixed setpoint control on following sensor


IThe differential control is deactvated if the temperature goes above the value set in this parameter.

ST501-LN1KV.04FS 4
Third level (A-level)
Simultaneously press the UP and DOWN button for about 3 seconds and ‘P1’ appears in the display.
Press the UP button until the highest p number is displayed. Keep the UP button pressed for a further 15 seconds and
the display will change to ‘PA’. Simultaneously press the UP and DOWN button until ‘A1’ is displayed.
To return to the operating mode: Simultaneously press the UP and DOWN button for aprox. 3 seconds and the display
will again show the process temperature. In any case if no adjustment of the parameters is made for 30 seconds, the
controller will automatically return to the operating mode.

Parameter Functions Adjustable Range Standard


Setting
A1 Switch mode control output 1 0: Heating contact 0
(not active when A98 = 1) 1: Cooling contact
A2 Switch mode control output 2 0: Heating contact
(not active when A98 = 1) 1: Cooling contact 1
A3 function of control output 1 0: Relay off 0
in case sensor error 1: Relay on
A4 function of control output 2 0: Relay off 0
in case sensor error 1: Relay on
A5 Setpoint 2 or 0: Setpoint 2 0
Delta W 1 1: Delta W1
A8 Actual value display ( Parameters 0: Whole numbers
remain 0.1 °K resolution ) 1: 0,5 °K resolution 1
1: 0,1 °K resolution
A19 Parameter Locking 0: No lock 0
1: A-Parameters locked
2: A&P-Parameters locked
A20 Reset error at E1 0: manual reset
message "F3" 1: automatic reset 1
A21 Reset error at E2 0: manual reset
message "F4" 1: automatic reset 1
A22 Reset error at E4 0: manual reset
message "F6" 1: automatic reset 1
A23 Reset alarm values sensor F1 0: manual reset
message "F7" 1: automatic reset 1
A24 Reset alarm values sensor F2 0: manual reset
message "F8" 1: automatic reset 1
A30 function alarm output 0: Boundary alarm relative boundaries 0
1: Boundary alarm, absolute boundaries
A31 Other alarm functions 0:Without function 0
1:Display flashing
2:Buzzer
3:Buzzer+Display flashing
A32 Setpoint display 0:not activated 0
1:Setpoint display only
A40 Hysteresis control output 1 0: Symmetrical
1: One side of Setpoint 1
A41 Hysteresis control output 2 0: Symmetrical
1: One side of Setpoint 1

ST501-LN1KV.04FS 5
A50 Minimum ON Time control output 1 0…600 sec 0 sec
A51 Minimum OFF Time control output 1 0…600 sec 0 sec
A52 Minimum ON Time control output 2 0…600 sec 0 sec
A53 Minimum OFF Time control output 2 0…600 sec 0 sec
A54 Time Delay for control after Mains ON 0…999 sec 0 sec
A56 Alarm Signal Delay after Mains ON 0...60 min 20 min
A57 Low pressure alarm Delay after first 0…600 sec 0 sec
compressor start
A58 Low pressure alarm Delay after 0…120 sec 0 sec
"low pressure alarm"
A59 time for number of low pressure alarms 0...60 min 45 min
defined in parameter A60
A60 number of low pressure alarms 0....100 8
before compressor stop
A65 Sensor selection 11: PT100 2-wire Dependent
21: KTY81-121 2-wire on
22: PT1000 2-wire Hardware
A70 Software time constant 1: not active
2...31: average value of "n" values 2
A80 Temperature Scale and 0: Fahrenheit and "AUS"
Display at Stand-By 1: Celsius and "AUS" 1
2: Fahrenheit and "OFF"
3: Celsius and "OFF"
A85 Function key F1 0: No function
1: actual value of sensor F2(leading value)
2: display of control setpoint
3: display of actual differential value
A86 Function key F2 00: No function
1: actual value of sensor F2(leading value)
2: display of control setpoint
3: display of actual differential value
A87 Function key 6 (Stand-By) 0: Not activated
1: Controller ON/OFF (Stand-By)
A90 function K1 1: Connected to pump 1
A91 function K2 2: Connected to control output 1 2
A92 function K3 3: Connected to control output 2 3
A93 function K4 4: Connected to alarm function 4
A94 Switch mode control input E1 0: active when open
pump 1: active when closed
A95 Switch mode control input E2 0: active when open 0
High pressure alarm only 0 is possible
A96 Switch mode control input E3 0: active when open 0
Low pressure alarm 1: active when closed
A97 Switch mode control input E4 0: active when open 0
motor protection compressor, fan 1: active when closed
A98 Activation of bypass control 0: No bypass
1: controll with bypass
A99 Control characteristics 0: Normal temperature control
F2 is deactivated
1: Differential control
2: Normal temperature control
F2 is active for alarme values
Pro Program Version - -

ST501-LN1KV.04FS 6
Third level, A-Parameters
A1: Switch mode control output 1
A2: Switch mode control output 2
Contact direction, i.e. cooling or heating function, can be individually set for each output relay.
Heating function - The output relay contact opens when the Setpoint is reached to switch the heating OFF
Cooling function - The output relay contact closes when the temperature is higher than the Setpoint and
switches the cooling power ON.

A3: Sensor error control output 1


A4: Sensor error control output 2
In the event of sensor open circuit or sensor short circuit, "F1-" flashes in the display.
Should this occur, each output relay can be independently programmed to switch ON or OFF..

A5: Selection Setpoint 2/Delta W


This gives a choice of either 2 independently adjustable contacts (Setpoint 2 operation),
or 2 interdependent contacts a pre-set distance apart (Delta W operation). See parameter "P1".

A8: Display mode


Option for setting the resolution of the display .

A19: Parameter locking


Allows graduated locking of the individual parameter levels. If locked the values can'
t be changed. The
display will show "===" if someone trys to change a locked value.

A20: Reset error at E1 ("F3")


With this parameter it is possible to define wether the the error F3 affords a manual reset or net

A21: Reset error at E1 ("F4")


With this parameter it is possible to define wether the the error F4 affords a manual reset or net

A22: Reset error at E4 ("F6")


With this parameter it is possible to define wether the the error F6 affords a manual reset or net

A22: Reset alarm values sensor F1 ("F7")


With this parameter it is possible to define wether the the error F7 affords a manual reset or net

A22: Reset alarm values sensor F1 ("F8")


With this parameter it is possible to define wether the the error F7 affords a manual reset or net

A30: Boundary Alarm function:


Boundary alarm:
If A30 is set to 0, K4 switches ON (contacts close) when the process temperature is above the upper or
below the lower boundaries. The values set in the parameters P30-P33 are related to the setpoint
If A30 is set to 1, K4 switches ON (contacts open) when the process temperature is above the upper or
below the lower boundaries. The values set in the parameters P30-P33 are absolute values.

A31: Other Alarm functions:


These parameters give the choice of a steady or flashing display with or without buzzer under alarm
conditions.

ST501-LN1KV.04FS 7
A32: Setpoint display:
The standard setting displays the process temperature. Setpoint 1 can be displayed momentarily by pressing
the SET button.
If setting 1 is chosen then the display shows Setpoint 1 only. i.e. there is no facility for displaying the process
temperature.

A40: Hysteresis mode control output 1 (K2)


The switch hysteresis can be adjusted to operate symmetrically or to one side about the setpoint. With
operation one side of Setpoint , the hysteresis is below Setpoint in heating application, and above Setpoint in
a cooling application.

A40: Hysteresis mode control output 2 (K3)


The switch hysteresis can be adjusted to operate symmetrically or to one side about the setpoint. With
operation one side of Setpoint , the hysteresis is below Setpoint in heating application, and above Setpoint in
a cooling application.

A50 Minimum ON time control output 1


A51 Minimum OFF time control output 1
A52 Minimum ON time control output 2
A53 Minimum OFF time control output 2

K1
A50

Switching behaviour t
(relay ON)

A51
K1

Switching behaviour t
(relay OFF)

A54: Time delay relay control output 1/2 after "Mains ON"
This parameter enables the operation to be delayed for a given period after "Mains ON"

ST501-LN1KV.04FS 8
A56: Alarm delay after "Mains ON"
This time delay prevents alarms from sounding after supply voltage has been switched on

A57: Low pressure alarm Delay after first compressor start


This time delay prevents alarms from sounding after the compressor has been switched the first tome on

A58: Low pressure alarm Delay after "low pressure alarm"


This time delay prevents alarms from sounding after low pressure alarm was on

A59: Alarm delay after "Mains ON"


This time delay prevents alarms from sounding after supply voltage has been switched on

A59: time for number of low pressure alarms defined in parameter A60
With this parameter you define the time for the number of low pressure alarms set in parameter A60, before
the compressor is blocked

A60: number of low pressure alarms


With this parameter you define the number of low pressure alarms during the time of parameter A59, before
the compressor is blocked

A70: Software time constant


This function controls the speed of response of the controller to any change in process temperature. It can be
used in applications where the sensor is too responsive to minor process temperature fluctuations, e.g.:
1 = No filter. Large variation in applications where the sensor is too responsive to minor process temperature
fluctuations. 6 = 96 sec. Extremely low variation in dynamic range, low sensitivity

A80: Temperatuer scale


This parameter enables the display to show readings in either Calsius or Fahrenheit. With this parameter you
also can configure the display showing "AUS" or "OFF" at Stand-By.

A85: Function key F1


A86: Function key F2
These parameters allow to give different functions to the keys F1 and F2.

A87: Function key 6 (StandBy)


This parameter allow to give different functions to the StandBy keys.

A90: Function output K1


A91: Function output K2
A92: Function output K3
A93: Function output K4
These parameters are fixed and can`t be changed at this controller.

A94: switch mode input E1


A95: switch mode input E2
A96: switch mode input E3
A97: switch mode input E4
With these parameters you set the input to normally closed or normally open activ.
Only E2 is fixed at normally closed and can`t be changed at this controller.

A98: Activation of bypass control

A99: Control characteristics

ST501-LN1KV.04FS 9
Error codes
Display error What to do
--- Keyboard lock active see Parameter P19 or A19
F1 sensor error sensor F1 new sensor
short circuit / open circuit
F2 sensor error sensor F1 new sensor
short circuit / open circuit
F3 input E1 activated (pump / niveau) Refill water and reset with DOWN-button
(if manual reset is activated) with
F4 input E2 activated (high pressure) maybee high ambient or water temperatur to high
reset with DOWN-button (if manual reset is activated)
F5 input E3 activated (low pressure) maybee low ambient or water temperatur to low
reset with DOWN-button (if manual reset is activated)
F5A compressor is blocked becaues the maybee low ambient or water temperatur to low
numberr of low pressure alarms was reset with DOWN-button
bigger than set in parameter A60
F6 input E4 activated (motor protection) check motor of compressor or fan.
reset with DOWN-button (if manual reset is activated)
F7 Temperature alarm sensor F1 cancel with ∇ button
F8 Temperature alarm sensor F2 cancel with ∇ button
EP lost of data in EE-Prom repair of controller

ST501-LN1KV.04FS 10
TECHNICAL DATA
Measuring Input
F1/F2: Resistance thermometer KTY 81-121
Measuring range: -50...150°C
Measuring accuray: +/- 1K or +/- 0,5%
of scale range, which ever is greater
or
Resistance thermometer Pt100
Measuring range: -80...400°C
Measuring accuray: +/- 1K or +/- 0,5%
of scale range, which ever is greater

switching input
E1: switching input for external potential free switch, function see Parameter A94
E2: switching input for external potential free switch, function see Parameter A95
E3: switching input for external potential free switch, function see Parameter A96
E4: switching input for external potential free switch, function see Parameter A97

Displays
One 3-digit, 13 mm high, red LED display
Three LED’s, diameter 3mm, for status display of the outputs K1, K2 and K3
Three LED’s, diameter 3mm, for status display of lower, upper fixed setpoint control and alarm
Foure LED’s, diameter 3mm, for status display of the inputs E1, E2, E3 and E4

Outputs
K1: Relay, 8(1,5) A, NO-contact, connected with supply voltage 12-24 AC/DC
K2: Relay, 8(1,5) A, NO-contact, connected with supply voltage 12-24 AC/DC
K3: Relay, 8(1,5) A, NO-contact, connected with supply voltage 12-24 AC/DC
K4: Relay, 8 A-contact (cosϕ=1), 250 V, changeover-contact, potential free

Power Supply
12...24 V=~, current consumption max. 20mA

Installation Data
Front panel: 106 x 68 mm
Panel cutout: 87,5mm x 56,5mm
Depth: approx. 85 mm incl. terminals
Mounting: 4 screws

Enclosure
Front IP65

Weight
approx. 160g

Ambient Conditions
Storage temperature: -20...+70 °C
Operating temperature: 0...+55 °C
Relative Humidity: max. 75% without dew

ST501-LN1KV.04FS 11
F1 F2 E1 E2 E3 E4

1 2 3 4 1 2 3 4 5 6 7 8
X8 X9

Spule K2

X5 X6 X7
1 2 1 2 3 4 1 2 3

K1 K2 K3 K4
je 8(1,5)A 250V~
12-24V =/~ 8(1,5)A

wiring diagramm

ST501-LN1KV.04FS 12