Você está na página 1de 17

TEAMTEC INCINERATORS

Market leaders since 1972 - More than 11 000 units sold worldwide

OG120C.
Capacity: 190.000 kcal/h (220 kW).

TEAMTEC Incinerator LOW OPERATION COSTS


model OG120C Our unique high temperature cyclone
burning principle ensures that all the
incinerators in TEAMTEC product range
can incinerate sludge oil (waste oil) with
water content up to 50% without using
The smallest incinerator in our support fuel, leaving our incinerators as
range. The sturdy, compact one of the most economical incinerators
design and high performance on the market.
make the OG120C an obvious TEAMTEC incinerators have no strainers
first choice for the waste or filters in the sludge oil system and this
treatment onboard small and in addition to several other advantages
keeps the maintenance costs to an
medium sized vessels. absolute minimum.

COMPACT DESIGN MODULAR CONSTRUCTION


The TEAMTEC high capacity incinerator All our incinerators are of a modular
models have one of the world’s smallest construction and can, if required, be
footprints and overall size. The delivered as a flat-packed unit for
incinerators can easily be installed in a assembling onboard the vessel/installation
corner. – no parts are bigger than a normal ship
door. No welding is needed.
Our incinerators are made from high quality
marine components only. This construction also benefits the life-time
maintenance works.
AUTOMATIC CONTROL
TEAMTEC incinerators are all controlled by
a high technology PLC ensuring a simple
and reliable operation, maximum
capacity utilisation and minimum fuel
consumption.

Minimum attendance is needed during MED APPROVED


operation and remote supervision is
possible.
TECHNICAL DATA – OG120C model:
version : C CW
190 000 kcal/h 190 000 kcal/h
Calorific capacity:
220 kW 220 kW
Sludge oil capacity *: 29 l/h N/A
Bilge water capacity: N/A N/A
Solid waste capacity: 200 l/load 200 l/load
Feeding sluice: - -
Self cleaning nozzle: Yes N/A
Total weight : 1 450 kg 1 350 kg
Dimensions (L x W x H
1033x1445x1836 1013x1445x1834
mm):
Footprint (L x W mm): 700x700 700x700
Fuel oil consumption: 11 kg/day 10 kg/h
Rated el. power (440V): 11 kW 7 kW

* IMO-defined sludge oil, 20% water content.

ALL VERSIONS:
Temperature in
Combustion chamber: 850 - 1 200 °C
Surface temperature: max. 15 °C above ambient temp.
Flue gas temperature: 350 °C (Optional 200oC)
Flue gas back pressure: max. 150 mm W.C.
Negative pressure in
Combustion chamber: from 10 to 35 mm W.C.

The C-version burns simultaneously sludge


oil and solid waste.

TEAMTEC incinerators are designed and


certified in compliance with the IMO
resolution MEPC 244(66) (prev. 76 (40))
and IMO MARPOL ANNEX VI.

MED certified and type approved by all


major classification societies, incl. US
Coast Guard.

OPTIONS:
• Skid/base mounted units
• Containerized units
• Remote control panel / slave panel
• Sludge oil and diesel oil tanks
• Diesel oil transfer and booster pumps
• Sludge tank level indicator in operator
display
• Heat tracing control for the sludge
circulation line
• Frequency controlled flue gas fan
• Flue gas stack components
• Solutions for ambient temp. above
o
55 C
• Project versions
Technical Specification
TEAMTEC INCINERATOR OG120C
Edition: TG5 (TeamTec Generation 5)
Market leaders since 1972 - More than 11 000 units sold worldwide

The incinerator consist of a combustion chamber with burner unit, sludge burning equipment, and
electric control panel, all assembled in one complete unit resting on four (4) feet or pads to be welded
or bolted to the deck or platform. Flue gas damper and cooling fan are delivered as separate units to
be installed in the flue gas duct or funnel.

TECHNICAL DATA – INCINERATOR:


Version : C CW version : C CW
Main Dimension El. Power consumption
2008787 2008781 2.0 kW 2.0 kW
Drawing diesel oil heater
Dimensions (L x W x H 1033 x 1445 x 1013 x 1445 x Nominal total electrical
8 kW 6 kW
mm) 1836 1834 power consumption
Total weight, kg 1268 1230 Total rated electrical
11 kW 7 kW
power consumption
Feeding door clear Recommended supply
300 x 750 300 x 750 20 A 16 A
opening (W x H mm) fuse
Sluice feeder opening N/A N/A
Sluice capacity,
N/A N/A Secondary air fan N/A N/A
l/charge
190 000 kcal/h 190 000 kcal/h Compressed air
Incineration thermal 20 norm.m³/h
requirement (for sludge N/A
capacity 7 bar
220 kW 220 kW atomizing)
Sludge oil burning Pipe connection air
29 l/h N/A 15 N/A
capacity nominal ** (DN)
Solid Waste capacity, Pipe connection for
200 l/charge 200 l/charge diesel line 15 15
batch load
Solid Waste continuous (supply/return) (DN)
N/A N/A Pipe connection for
charging, kg/h
sludge oil line 25 N/A
Water Injection capacity N/A N/A (supply/return) (DN)
Negative pressure 5 – 20 mm WC 10 – 28 mm WC Pipe connection bilge
N/A N/A
water (DN)
Outer skin temperature
15°C 15°C Pipe connection for
above ambient
drain of spill collector - / 1” - / 1”
Working temperature
850 – 1150°C 850 – 1150°C (DN/BSP)
combustion chamber
Flue gas outlet
Max temperature 200 200
1200°C 1200°C dimension (DN)
combustion chamber
Minimum distance
Working temperature
250 – 350°C 250 – 350°C between incinerator flue
flue gas
gas outlet and first 2500 mm 2500 mm
Diesel oil viscosity
13 cSt at 40°C 13 cSt at 40°C component on the flue
(max)
gas line
Diesel oil consumption
when support burner is Incinerator body color RAL 6019 RAL 6019
10 / - 10 / -
in operation 1 / 2 Control panel color RAL 7035 RAL 7035
nozzles, l/h

** IMO-defined sludge oil, 20% water content.


TECHNICAL DATA – FLUE GAS DAMPER:
Version : C and CW
Main Dimension Drawing 3007338
Flange connection inlet
200
(from incinerator) (DN)
Flange connection outlet
200
(fan side) (DN)
Weight, kg 20
Color (heat resistant) Aluminum

TECHNICAL DATA – FLUE GAS FAN:


Version : C and CW
Main Dimension Drawing 4007653
Flue gas fan outer
863 x 856 x 800 mm
dimension (L x W x H)
Flue gas duct dimension
200 / 200
(inlet/outlet) (DN)
Weight, kg 175
Flue gas fan capacity,
3 500 m³/h
maximum
Ventilation requirement 1 750 m³/h
Back pressure, maximum 100 mm WC
Separate starter
N/A
recommended fuse
Rated power
consumption from N/A
separate supply
Color (heat resistant) Aluminum

TECHNICAL DATA – EXPANSION COMPENSATOR:


Version : C and CW
Flange connection (DN) 200
Acc. to SPS std
39- Spare part list
Article / Name 17982 / Minimum Spare Parts, OG120C, TG5

Art. no. Art. name Quantity Unit


15686 Bonded Stator, Blue mark 1,00 ea.
18925 TeamTec Incinerator Service Video (as USB-stick) 1,00 ea.
8334 Photo resistor. QRB 1B 1,00 ea.

RESPACK 16.09.2015 1 of 1
39- Spare part list
Article / Name 18241 / One year wear and tear parts, OG120C, TG4/5

Art. no. Art. name Quantity Unit


13530 Glassfibre Rope 15x20 3,00 M
15686 Bonded Stator, Blue mark 2,00 ea.
15688 Universal Joint 1,00 ea.
15731 V-belt, XPZ 987 2,00 ea.
15912 Rotor 1,00 ea.
17168 Stuffing Box Gasket 1,00 ea.
17691 Sealing Compound, NON DANGEROUS GOODS 1,00 ea.
6996 Cover gasket 2,00 ea.
9825 Nozzle 2,5 gph 30° 2,00 ea.

RESPACK 14.09.2015 1 of 1
39- Spare part list
Article / Name 18242 / Recommended on board repair parts, OG120C, TG4/5

Art. no. Art. name Quantity Unit


11069 Thermocouple with Pocket 1,00 ea.
11878 CALDE PATCH PT 88 U 25,00 KG
12500 Thermocouple Type "N-300" Assembly 1,00 ea.
12501 Thermocouple Type "K" Assembly 1,00 ea.
15556 Solenoid Valve, G1/4", 220V, 3-Way 1,00 ea.
15687 Seal Plate Gasket 1,00 ea.
15741 Mechanical Seal 1,00 ea.
17168 Stuffing Box Gasket 1,00 ea.
4078 Flue Gas Restriction Ring Brick OG 120C 2,00 ea.
4365 Ignition Electrodes 1,00 ea.
4374 Ignition Cable Compl. L=580 2,00 ea.
4995 Bearing, 2209 EK 2,00 ea.
5604 Spline Coupling Compl. for 210K 1,00 ea.
6406 Repair kit for sludge valve A6323 1,00 ea.
6987 Press. regulator kit, 10-21 bars 1,00 ea.
8126 Solenoid Valve, G1/4", 220V 1,00 ea.
8334 Photo resistor. QRB 1B 1,00 ea.
8454 Solenoid Valve, 1/8", 220V 1,00 ea.
8628 Blast Tube 1,00 ea.
8760 Flame Scrod, OG 120 1,00 ea.
8762 Nozzle Line 1,00 ea.
9272 Shaft seal kit 1,00 ea.
9731 Sludge Oil Burner Assembly 1,00 ea.

RESPACK 14.09.2015 1 of 1