1. General
A. This section gives the procedures to clean the cross-bleed valve filter.
C. The cross-bleed valve is installed in the lower fairing area between the LH and RH air conditioning
packs.
E. The abbreviations and acronyms used in this section are given in the sequence below:
ABBREVIATION DESCRIPTION
TASK 36-10-01-130-801-A
EFFECTIVITY: ALL
(1) This task gives the procedure to do the cleaning of the cross-bleed valve filter in zone 191.
B. References
REFERENCE DESIGNATION
ZONES
LOCATION REFERENCE
ACCESS
D. Job Set-Up
WARNING: MAKE SURE THAT THE AIRCRAFT IS IN A SAFE CONDITION BEFORE YOU DO THE
MAINTENANCE PROCEDURES. THIS IS TO PREVENT INJURY TO PERSONS AND/
OR DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE LANDING GEAR SAFETY PINS ARE INSTALLED. THIS IS TO
PREVENT INJURIES TO PERSONS AND DAMAGE TO MATERIAL.
WARNING: DO NOT TOUCH THE DUCTS OR COMPONENTS OF THE AIR BLEED SYSTEM
IMMEDIATELY AFTER THE SYSTEM STOPS ITS OPERATION. THE HIGH AIR
TEMPERATURE CAN CAUSE INJURY TO PERSONS.
SUBTASK 940-001-A
(1) Do the procedure to make the aircraft safe for maintenance (AMM TASK
20-00-00-910-801-A/200 ).
SUBTASK 020-001-A
(2) Remove the cross-bleed valve filter (AMM TASK 36-10-01-000-802-A/400 ).
EFFECTIVITY: ALL
Cross-Bleed Valve Filter - Cleaning
Figure 701
ZONE
191
A
PLUG
PACKING LOCKWIRE A
SPRING
FILTER
EM170MPP360040A.DGN
CROSS−BLEED
VALVE (REF.)
TASK 36-10-01-100-801-A
EFFECTIVITY: ALL
(1) This task gives the procedure to do the cleaning of the cross-bleed valve filter in zone 191.
B. References
REFERENCE DESIGNATION
ZONES
LOCATION REFERENCE
ACCESS
REFERENCE DESIGNATION
E. Consumable Materials
F. Job Set-Up
WARNING: MAKE SURE THAT THE AIRCRAFT IS IN A SAFE CONDITION BEFORE YOU DO THE
MAINTENANCE PROCEDURES. THIS IS TO PREVENT INJURY TO PERSONS AND/
OR DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE LANDING GEAR SAFETY PINS ARE INSTALLED. THIS IS TO
PREVENT INJURIES TO PERSONS AND DAMAGE TO MATERIAL.
WARNING: DO NOT TOUCH THE DUCTS OR COMPONENTS OF THE AIR BLEED SYSTEM
IMMEDIATELY AFTER THE SYSTEM STOPS ITS OPERATION. THE HIGH AIR
TEMPERATURE CAN CAUSE INJURY TO PERSONS.
SUBTASK 940-003-A
(1) Do the procedure to make the aircraft safe for maintenance (AMM TASK
20-00-00-910-801-A/200 ).
SUBTASK 020-003-A
(2) Remove the cross-bleed valve filter (AMM TASK 36-10-01-000-802-A/400 ).
G. Cross-Bleed Valve Filter - Cleaning (Figure 702)
SUBTASK 100-002-A
(2) Spray the filter with Electro 140° Contact Cleaner - 00916 - Aerosol.
(5) Visually examine the filter screen for signs of blockage. Clean the filter (AMM TASK
36-10-01-130-801-A/700 ) as necessary.
NOTE: You can use a flashlight and a 10X magnifying lens as aids to do the
inspection.
H. Job Close-Up
SUBTASK 420-003-A
(1) Install the cross-bleed valve filter (AMM TASK 36-10-01-400-802-A/400 ).
EFFECTIVITY: ALL
Cross-Bleed Valve Filter - Cleaning
Figure 702
ZONE
191
A
PLUG
PACKING LOCKWIRE A
SPRING
FILTER
EM170MPP360040A.DGN
CROSS−BLEED
VALVE (REF.)