MATERIAL CLAUSE TEST FIELD/LAB TEST METHOD MIN QTY MATERIAL REQUIRED FREQUENCY OF TEST RESPONSIBILITY WITNESS

ASTM D4945-08, IS-


Dynamic Test FIELD 9716:1981 (IS : 2911) 0.01% of total number Site / Quality Engineer Client Representative
ASTM-D5882-00, IS –
Integrity Test FIELD 14893, IS-2911 50% of total number Site / Quality Engineer Client Representative

Particle size fileld/lab 45 m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Estimation organic inpuries field/lab IS 2386-PART 2 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Surface moister field/lab IS 2386 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Aggregate Determination of 10% fine value field/lab IS 2386 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Specific gravity field/lab IS 2386 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

bulk density field/lab IS 2386 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Agg.Crushing strength field/lab IS 2386 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Agg.compaction field/lab IS 2386 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative

Standard consistency of cement by


Vicats Apparatus Lab IS 4031 Part 6 Each Lot Every 50 tonnes or part thereof. Each brand of cement brought to site shall be tested as per this frequency Site / Quality Engineer Client Representative

Fineness Lab IS 4031 Part 2 Each Lot Every 50 tonnes or part thereof. Each brand of cement brought to site shall be tested as per this frequency Site / Quality Engineer Client Representative
Cement
Soundness Lab IS 4031 Part 3 Each Lot Every 50 tonnes or part thereof. Each brand of cement brought to site shall be tested as per this frequency Site / Quality Engineer Client Representative

Setting time (Initial & Final) Lab IS 4031 Part 5 Each Lot Every 50 tonnes or part thereof. Each brand of cement brought to site shall be tested as per this frequency Site / Quality Engineer Client Representative

Compressive strength Lab IS 4031 Part 6 Each Lot Every 50 tonnes or part thereof. Each brand of cement brought to site shall be tested as per this frequency Site / Quality Engineer Client Representative

Sieve Analysis field/lab IS 2386 Site / Quality Engineer Site / Quality Engineer Client Representative
F.A.
Silt content field/lab IS 2386 Site / Quality Engineer Site / Quality Engineer Client Representative
bulk density field/lab IS 2386(part 3) 10m^3 for every 45m^3 or part there of rcc work Site / Quality Engineer Client Representative
for every 15m^3 or part there of rcc work Site / Quality Engineer
Concrete 4.2.2 Slump test field/lab IS 526 10m^3 Client Representative
Cube strength field/lab IS 527 10m^3 for every 15m^3 or part there of rcc work Site / Quality Engineer Client Representative

10.1.1 Tensile Strength


Reinforce Bend lab IS 1599, 1608, 1786 20 Tonne Every 20 tonne Site / Quality Engineer Client Representative
me nt % Elongation
Chemical Properties
Unit Weight & Diameter

Solid Content Out-side Lab 1KG Once in 6 month


Chloride Content Out-side Lab 1KG Once in 6 month
Sulphate Content Out-side Lab 1KG Once in 6 month
Admixture PH Out-side Lab IS 9103 1KG Once in 6 month Site / Quality Engineer Client Representative
Specific Gravity Out-side Lab Every batch
Effect On Setting Time Site Lab Every batch
Effect On Strength Site Lab Every batch
Slump Retentation Site Lab Every batch

Chemical & Physical Properties


PH Value
Limits of Acidity
Limits of Alkality
Percentage of solids
(a) Chlorides Water from each source shall be got tested before the commencement of work & thereafter once in every three months till the
Water (b) Suspended matter Lab IS 3025 Site / Quality Engineer Client Representative
completion of work. Water from muncipal source need be tested only in once in six month.
(c) Sulphates

(d) Inorganic solids