ABSTRACT
Gas absorption is a process in which the soluble parts of mixture are transferred to a
liquid.Gas absorption is done in a packed column .This report are done as to examine the
air pressure drop across the column as a function of air flow rate for different water flow
rates through the column. When the air pressure drop to certain limit, the phenomena
known as ‘flooding’ will occur in which the system can no longer operate as it is. Hence
1
the ‘flooding point’ is to be determined as to make sure that the process should be made
INTRODUCTION
Gas absorption is a process in which the soluble parts of a gas mixture are transferred to
. Therefore there will be mass transfer of the component of the gas from the gas phase to
2
the liquid phase. The solute transferred is said to be absorbed by the liquid. In gas
desorption (or stripping), the mass transfer is in the opposite direction, of which the
transfer is from the liquid phase to the gas phase. The principles for both systems are the
same. But from here and on, we are only interested in gas absorption .
absorption,depending on whether there is any chemical reaction between the solute and
the solvent(absorbent).
When water and hydrocarbon oils are used as absorbents, no significant chemical
reactions occur between the absorbent and the solute, and the process is commonly
used as the absorbent to dissolve an acid gas, absorption is accompanied by a rapid and
irreversible neutralization reaction in the liquid phase and the process is referred to as
AIMS
To examine the air pressure drop across the column as a function of air flow rate for
THEORY
is brought into contact with a liquid and during this contact a component is transferred
3
between the gas stream and the liquid stream. The gas may be bubbled through the liquid,
or it may be passed over streams of the liquid, arranged to provide a large surface through
which the mass transfer can occur. The liquid film in this latter case can flow down the
sides of columns or over packing, or it can cascade from one tray to another with the
liquid falling and the gas rising in the counter flow. The gas, or components of it, either
dissolves in the liquid (absorption) or extracts a volatile component from the liquid
(desorption). [2]
In every packed tower with a given size of packing and type , has an upper limit to the
rate of gas flow known as flooding velocity of which the tower cannot operate above the
velocity mentioned earlier. At low gas velocities the liquid flows downward through the
packing uninfluenced by the upward gas flow. As the gas flow rate increases at low gas
velocities the pressure drop starts to rise at higher rate. The liquid accumulation increases
as the gas flow rate is increased . At the flooding point, the liquid will no longer have the
ability to flow down through the pack column and later is blown out with or by the gas.
[3]
APPARATUS
4
5
METHODOLOGY / PROCEDURES
A) General start-up
3. The valve on the compressed air supply line is opened. The supply pressure is setted
4. The shut-off valve on CO2 gas cylinder is opened. The CO2 gas cylinder pressure is
ensured to be sufficient.
6
Presssure Drop)
2. The receiving vessel B2 is filled with 50 L of water by opening valve V3 and V5.
3. Valve V3 is closed.
4. Valve V10 and valve V9 are slightly opened. The flow of water from vessel B1
5. Pump 1 is switched on then valve V11 is slowly opened and adjusted to give a water
flow rate of around 1 L/min. Water is allowed to enter the top of column K1, flow
down the column and accumulate at the bottom until it overflows back to vessel B1.
6. Valve 11 is opened and and adjusted to give a water fow rate of 0.5 L/min into
column K1.
7. Valve V1 is opened and adjusted to give an air flow rate of 40L/min into column K1.
8. The liquid and gas flow in the column 1 are observed , the pressure drop across the
9. Steps 6 to 7 are repeated with different values of air flow rate, where each time is
10. Steps 5 to 8 are repeated with different values of water flow rate, of which each time
3. The valves on the compressed air supply line is closed and the supply pressure is
7
exhausted by turning the regulator knob counterclockwise all the way.
6. All iquid from receiving vessels B1 and B2 are drained by opening valves V7 and
V8.
8
Figure 1: Pressure Drop vs. Air Flow Rate
Sample Calculations
Data:
GG = GyXp / A
9
3
20L 1min 1.175kg 1m
= min 60 sec m3 1000L
0.0050207
=0.0779kg/m2s
0.1
13.1(GG )2 F p ( L )
= L
G (PL PG )
0.1
2 0.001 )
= 13.1(0.0779) 900( =0.0154
996
1.175(996 1.175)
GL X p
=
A
1L1min 1.175kg 1m3
= min 60 sec m3 1000L
0.005027
( G )
GL
x-axis =
GG L
10
=3.032
(L/min) r (y-axis)
20 0.0779 0.0154 1.0 LPM 2.0LPM 3.0LPM
11
Table 3 :Air Flowrate ,gas flow rate (kg/m2s) abrv. GG ,capacity parameter and flow
parameter.
12
(L/min) Flooding Air Flooding Air
DISCUSSION
In this experiment, the interest is to examine the air pressure drop across the column as a
function of air flow rate for different water flow rates through the column. The
experiment based on the flow rate of liquid and gas in the packed.
Firstly the water flow rate is kept constant to 1 L/min and the air flow rate is then
recorded after a 1 minute interval. Air flow rate is kept rising at constant by 20 L/min by
each 5 minutes. All reading of pressure drop are then recorded until the flooding point is
reached. The pressure drop for flow rate of air are 0,2,6,7,9,10,13,21,58 mm H20
The flow rate of water is then adjusted to 2 L/min, the data recorded are 8,2,0,3,9,30,53
13
mm H20 respectively to 20,40,60,80,100,120,140,160 L/min of air. It cannot reach 180
L/min of air flow rate as the water will sprayed out from the column due to the high flow
rate. Theoretically, the pressure drop will increase as the air flow rate of air is increased,
however at the beginning of the experiment , the pump suddenly failed to work as an
As the water flow rate is increased to 3 L/min, the datas are , 0,2,7,13,39 mm H20
respectively to 20,40,60 and 80 L/min of air . Beyond 80 L/min of air , the flooding
occurs.
The graph of column Pressure Drop vs. Air Flow Rate is plotted and in which the results
from the plotted graph shown the higher the gas flow rate , the higher the pressure drop.
For correlated value of the pressure drop,calculations has ben made and a graph of
capacity parameter against flow rate parameter is plotted. The capacity parameter is
CONCLUSION
In conclusion, the air pressure drop across the column increases as the air flow rate
increases as well as the water flow rate through the column. From the experiment, the
value of experimental pressure drop is higher compared to the correlated values for
packed column. For packed column of water flowrate of 1 LPM, the error invovled is the
lowest that is 11.1 %, followed by that of water flowrate of 2 LPM which is 14.28 % . At
water flowrate of 3 LPM, the error involved is 20% . These percentage errors between
theoretical and correlated calculations of flooding point are slightly high due to some
unexpected instrumental error as the pump suddenly shut off in the middle of the
experiment. Hence, all instruments must be checked before any experiment is conducted
to ensure the accuracy of the outcomes.
14
RECOMMENDATIONS
Some suggestion in improving the safety are to always check and rectify any leak and all
operating instructions supplied with the unit must be carefully read and understood before
attempting to operate the unit. Next, be extremely careful when handling hazardous,
flammable or polluting materials such as CO2. Make sure the system is sufficiently
REFERENCES
[1] Perry, Robert H., and Green. Perry's Chemical Engineers' Handbook. New York:
http://www.nzifst.org.nz/unitoperations/conteqseparation8.htm
[3] Geankoplis, C.J. (2003). Transport Processes and Separation Process Principle, 4th
15
(http://www.separationprocesses.com
16
APPENDIX
17