THD %
even check the quality of an electrical system ,with good Run Hours (min current >50mA) resettable Temperature:
K M
stability and high accuracy. ON hours (lifetime counter) Ambient temperature: -10° C to 55° C
MAX AL1 MIN
ENT
SET-UP SCROLL RS 485 serial port with standard MODBUS RTU protocol. Storage temperature: -10° C to 70° C
SL 6300 Measures Minimum value of VLN,VLL,I,A. Relative Humidity: <95%, Non-condensing
SERIES
Measures Maximum value of VLN,VLL,I,A. Net Weight: 550 gm(approx)
R
Measures Maximum Demand Value. Gross Weight: 600 gm(approx)
www.nippenco.com
Error Indication of Phase sequence and CT reverse.
1 4
PAGEWISE DETAILS
LED’S LED’S Model
Description S.No Display Description
UNIQUE FEATURES Monitors Energy kWh,Import & Export, Reactive of capacitive, S.No Display “ON” Model “ON”
1 VLN VLN Voltage line to Neutral All model 23 h s Run hours (Life Time Counter) All model
True RMS measurement & 4 quadrant operation. Reactive of Inductive,kVAh. 2 VLL VLL Voltage line to line All model 24 hrs Load hours (re-settable) All model
3 A A Line current All model 25 acet E Total Active Energy (kwh) consumed (EB) All model
Simultaneous sampling of volts & amps . Dual Source(DG) sensing with energy. K
4 F E HZ Frequency All model 26 aeet E
K Energy Export (EB) All model
0.5 % accuracy in Multifunction Metering. Pulse 1000 pulses/kWh. 5 W W Active power All model 27 a et E
K Energy Import (EB) All model
6 VAr Var Reactive power All model 28 eet E Reactive Energy Total (Algebraic Sum) (EB) All model
%Harmonics measurement for voltage and current Minimum & maximum values stored for VLN,VLL,I,Hz. 7 VA VA Apparent power All model
K
29 cet E
K Capacitive reactive Energy (EB) All model
8 P F. P.F. Power Factor of system All model 30 let E Inductive reactive Energy (EB) All model
K
(up to 31st Harmonic) 9 VLN THD%
VLN
% Harmonics for Voltage All model
INPUTs THD%
A
31 apet E
K Apparent Energy (EB) KVAh All model
10 A THD% % Harmonics for Current All model 32
c
RS 485 communication port(Modbus-RTU) All model
CT reverse polarity Auto detecting. THD%
Maximum Demand
11 k W o r k VA MD MD model 33 ac. E Total Active Energy (kwh) consumed (DG) DG model
Voltage Input : 80 to 500VAC K DG
Phase sequence error indication. 12 RTC Real Time Clock All model 34 ae E DG Energy Export (DG) DG model
K
CT primary setting from 5A-9999A 13 Ala AL 1 Alarm status All model
c Maximum Demand Relay status MD model
35 a E
K DG Energy Import (DG) DG model
14
Single Relay output for alarm trip.(VLN,VLL,HZ,Amps,THD %,kw,PF) PSE- Phase sequence error 36 e E
K DG Reactive Energy Total (Algebraic Sum) (DG) DG model
Auxiliary Supply : 80 - 300VAC/DC. 15 E psE - CT reverse phase wise 37 c E DG Capacitive reactive Energy (DG) DG model
All model K
Manual and Auto scrolling facility. l E Inductive reactive Energy (DG)
Frequency : 45 to 60Hz 16 a ug VLN Average voltage line to Neutral All model 38 K DG DG model
Password protection. 17 a ug VLL Average voltage Phase to Phase All model 39 ap E
K DG Apparent Energy (DG) KVAh DG model
Power factor : 0.5lead - Unity-0.5Lag
18 a ug A Average Current All model
User configurable (Editable) Password. 19 o l W Total Active Power ie W, kW etc All model
Communication with PCs, PLCs, DCS through an optional RS485 20 o l kVAr Total Reactive Power VAr kVAr etc All model
21 o l kVA Total Apparent Power VA, kVA etc All model
Serial Port (MODBUS RTU). 22 a ug P.F Average PF All model
2 5
3 6
1 SL6300 2 SL6300 3 SL6300 4 SL6300 5 SL6300 6 SL6300 7 SL6300 8 SL6300 9 SL6300 10 SL6300
1.000
E E E E
VLN VLN VLN VLN VLN VLN VLN VLN VLN VLN
VLL VLL VLL VLL VLL VLL VLL VLL VLL VLL
Hz Hz Hz Hz Hz Hz Hz Hz Hz Hz
220.0 380.0 5.000 5.000 0.00 0.00 1.000 0.99 0.00 0.00
A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE
P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F.
MD MD MD MD MD MD MD MD MD MD
THD % THD % THD % THD % THD % THD % THD % THD % THD % THD %
K M K M K M K M K M K M K M K M K M K M
SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP ENT SET-UP ENT
SCROLL SCROLL
MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1MIN MAX AL1 MIN MAX AL1 MIN MAX AL1MIN MAX AL1 MIN
Voltage Line-Neutral(L1,L2,L3) Voltage Line-Line(L1L2,L2L3,L3L1) Current(I1,I2,I3) Frequency Hz Active power(kW) Reactive power(kVAr) Apparent power(kVA) Power Factor THD%VLN THD% AMPERE (I)
LEAD P.F- indicate by -ve sign
LAG P.F- indicate by without +ve sign
11 SL6300 12 SL6300 13 SL6300 14 SL6300 15 SL6300 16 SL6300 17 SL6300 18 SL6300 19 SL6300 20 SL6300
00
VA VA VA VA VA VA VA VA
0000 20-
E
pse
E E E E E E E E E
VLN VLN VLN VLN VLN VLN VLN VLN VLN VLN
VLL VLL VLL VLL VLL VLL VLL VLL VLL VLL
0000
Hz Hz Hz Hz Hz Hz Hz Hz Hz Hz
THD % THD % THD % THD % THD % THD % THD % THD % THD % THD %
K M K M K M K M K M K M K M K M K M K M
SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP ENT SET-UP SCROLL ENT SET-UP SCROLL ENT
SCROLL
MAX AL1 MIN MAX AL1 MIN MAX AL1MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1MIN MAX AL1MIN
Maximum demand REAL TIME CLOCK ALARM STATUS MD relay status ERROR Page Average Line Neutral Average Line Line Total active power kW Total Reactive power kVAr
L1 - Present demand 30min
Average Ampere
L2 - Predictive demand 15min PSE - Phase seq.error
L3 - Instantaneous demand rrr - CT polarity reverse
21 SL6300 22 SL6300 23 SL6300 24 SL6300 25 SL6300 26 SL6300 27 SL6300 28 SL6300 29 SL6300 30 SL6300
0.00 0.99 00.99 00.99 0000 0000 0000 0000 0000 0000
A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE
P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F.
MD MD MD MD MD MD MD MD MD MD
RL1 RL1 RL1 RL1 RL1 RL1
THD % THD % THD % THD % THD % THD % THD % THD % THD % THD %
K M K M K M K M K M K M K M K M K M K M
SET-UP ENT SET-UP ENT SET-UP ENT SET-UP ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP ENT SET-UP ENT
SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL
MIN MAX MIN MAX MIN MAX MIN MAX MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN
RUN Hours LOAD Hours Maximum Value(VLn) Minimum Value(VLn) Maximum Value(VLL) Minimum Value(VLL) Maximum Value(Ampere) Minimum Value(Ampere)
Total apparent power kVA Average Power factor
31 SL6300 32 SL6300 33 SL6300 34 SL6300 35 SL6300 36 SL6300 37 SL6300 38 SL6300 39 SL6300 40 SL6300
0000 0000 0.099 0.099 00.99 00.99 00.99 00.99 00.99 00.99
A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE A PULSE
P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F. P.F.
MD MD MD MD MD MD MD MD MD MD
THD % THD % THD % THD % THD % THD % THD % THD % THD % THD %
K M K M K M K M K M K M K M K M K M K M
SET-UP ENT SET-UP ENT SET-UP ENT SET-UP ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT
SET-UP SCROLL ENT SET-UP SCROLL ENT SCROLL SCROLL SCROLL SCROLL
MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN
Maximum Value(Hz) Minimum Value(Hz) Active energy total(kWh) Active energy import(kWh) Active energy export(kWh) Reactive energy total (kVArh) Reactive capacitive energy Reactive inductive energy Apparent Energy KVAh Active energy total DG(kWh)
kVArh-capacitive kVArh-Inductive
41 SL6300 42 SL6300 43 SL6300 44 SL6300 45 SL6300 46 SL6300
ae a E c ap Programming Mode
W W W W W W
VAr VAr VAr VAr VAr VAr
VA VA VA VA VA VA
gen
A PULSE A PULSE A PULSE A PULSE A PULSE PULSE
K M K M K M K M K M K M
In order to operate for all the field programmable parameters, it is easy for user
SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT SET-UP SCROLL ENT
MAX AL1 MIN
SET-UP SCROLL ENT
MAX AL1 MIN
SET-UP SCROLL ENT interface by pressing the keys such as , , and . Once the display is in
MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN MAX AL1 MIN
Active energy export DG Active energy import DG Reactive energy total DG Reactive inductive energy Reactive capacitive energy Apparent Energy DG KVAh
Programming Mode, press key to move into the following programmable parameters:
(kVArh) DG kVArh-capacitive
parameter. 1)VLn,VLL,A,Hz,THD,kW,PF
(kWh) (kWh) DG kVArh-Inductive
3)Current tarrif
3)RTC Real Time clock
right side in programming mode.
cl e
4)ID to Rs485
1) a - Tarrif
ala
parameter
UP Direction key to scroll the alpha numeric value 0-9 in programming mode and To scroll the pages forward 5)c.run-Clear load Hours
ou
parameter
parameter
d
direction in RUN mode. To go into Scroll mode ON continuous press 7Sec. 6)C.HL-Reset min,max value
Down Direction key to scroll the alpha numeric value 9-0 in direction and To scroll the pages reverse direction in 7)PASS-Meter password
RUN MODE. To go into Scroll mode OFF continuous press 7Sec.
Complete the operation in programming mode once have done, ENTER. 7
Setting the Main CT Ratio Meter ID to RS 485 Setting Password 4. Then display goes TRIP1 of TARRIF1.Set demand valu
Press SET UP key on Run Mode for about FIVE Press SET UP key on Run Mode for about FIVE in trip relay 1 to relay 4. Set Value by pressing
In order to give actual current values in your systems,
seconds continuously, the unit will therefore enter seconds continuously, the unit will therefore enter , , , keys until desired value is received,
the main CT Ratio between the primary and secondary
into Programming Mode such as shown below. into Programming Mode such as shown below. Press enter key to go to trip relay 2 to relay 4.
current should be set accordingly. The CT Ratio can be
set from 5 A to 9999 A. GEN gen Once TARIFF1 done, Press ENTER key to set TRIP
relay 1 to TRIP4 of TARRIF2. Do same setting.
1. On pressing enter key once, the display will 1. On pressing enter key once, the display will
Press SET UP key on Run Mode for about FIVE
prompt c P .
prompt c P .
4 relay ouputs are indicates
p.1 p.2
p. p.3
p. p.4
p.
seconds continuously, the unit will therefore enter
into Programming Mode such as shown below. 2. Press key five time, the display will 2. Press key eight time, the display will
c relay 1 relay 2 relay 3 relay 4
gen
prompt . prompt pass.
3. Here user can set desired password. On pressing 5. Once TARRIF 2 to 4 done, On pressing ENTER key
3. Here meter ID to be set for RS 485 communication
On Pressing Enter key once, the display will prompt enter key once, the display indicates default the display will return to tarrif function.
protocol .On pressing enter key once, the display
C P indicates default 001on the display. Set meter ID value 0000. Set password by using , , ,
key until desired password value is received.
6. Then Press DOWN key , to display indicates
gen
prompt .
once the display indicates default value 0220. 2. Press key seven time, the display will
Set PT secondary by pressing , , keys until prompt c.hl 1. Press UP key twice, the display will prompt
2. Press ENTER key to set the maximum demand interval
3. Here maximum current demand Interval to be set
ou
desired PT value is received .Press enter key to 3. Here initially RESET the minimum ,maximum
conform the value stored. value of Vln, VLL, Ampere , Frequency.
Time of unit. here.The default value indicates 015 . Set interval
by pressing , , key until desired value is
On pressing enter key once, the display indicates 2. On pressing ENTER key , the display will prompt
4. If the CONTROL mode is not desired, Press key received.Then Press enter key to conform the
to go to the parameter . Or else, Press SET UP su e screen on the display.Then press enter key a Tarrif. value is stored.Then Press UP & down key to select
key twice to return into Run Mode. to conform the value is resetted. the Demand Type(kW or kVA)
3. Press ENTER key , to set the number of tarrif as
Example
4. If the CONTROL mode is not desired, Press key per required and enter to store the same. ac P - kW apP.p
- kVA
11KV/110V PTPR -1100 ; PTSC - 0011
to go to the desired parameter . Or else, Press
SET UP key twice to return into Run Mode. a - TARRIF. To set demand value(kW or kVA) 4. If the CONTROL mode is not desired, Press key
to go to the desired parameter . Or else, Press
22KV/110V PTPR -2200 ; PTSC - 0011
8 a .1 a .2 a .3 a .4 SET UP key twice to return into Run Mode.
Alarm configuration COMMUNICATION REGISTER MAP 2008 kVArh Capacitive ce 1
Parameters as follows 2010 le 1
I1
Press SET UP key on Run Mode for about FIVE kVArh Inducitive
Data Bits : 8 2012 kVAh - ape 1
seconds continuously, the unit will therefore enter Baud Rate : 9600Bps (19200Bps on Request) 2014 kWh DG ac 1
into Programming Mode such as shown below. Stop Bits : 1 ae
I2
2016 kWh DG Export - 1
gen
Parity : None
Data Format : Float 2018 kWh DG Import - a 1
2020 kVArh DG - e 1
1. On pressing key four time, the display will Address Parameter Mulitplier
1
ala
2022 c
I3
kVArh Capacitive
S32
80-300VAC/DC
N
AUX. SUPPLY
Here we can set ALARM trip point to relay output,for 1006 Current - I1 1
1008 Current - I2 1
S31
VLn,VLL,Current,Hz,THD% ,kW,PF .
P
1010 Current - I3 1
al .1 1012 kw-L1 1 ENERGY RESOLUTION
S22
3. Press enter key to indicates the display COM Common
1014 kw-L2 1
CT Primary& PT Wh VA h kW kVA
4. On pressing enter key again, the display indicates 1
S21
1016 kw-L3 Primary/Secondary Relay 1
R1
uln screen on the display. Suppose,we required 1018 kVAr (L1) 1 5Primary<=5 00000.000K 00000.000K 0.000K 0.000K
S12
VLL or current,Hz,THD,kW,PF. Press key to select 1020 kVAr (L2) 1 Relay 2
5>Primary<=50 000000.00K 000000.00K 00.00K 00.00K R2
1022 kVAr (L3) 1
the desired parameters. Once the desired parameters 50>Primary<=500
S11
1024 kVA (L1) 1 0000000.0K 0000000.0K 000.0K 000.0K
selected, Press enter key to display indicates oue 1026 kVA (L2) 1 500>Primary<=5000 00000000K 00000000K 0.000M 0.000M R3 Relay 3
It means over limit relay selected. Then Press ENTER 1028 kVA (L3) 1 000000.00M 000000.00M 0.000M 0.000M
N
5001>Primary<=9999
R4 Relay 4
key to conform or Press key to select under und 1030 PF-L1 1
<=5 & PT11KV/110V 000000.00K 000000.00K 000.0K 000.0K
L3
1032 PF-L2 1
00000000K 00000000K AL 1 Alarm Relay 1
5. Once OVER or UNDER selected,Press ENTER key to go 1034 PF-L3 1 <=5 & PT22KV/110V
L2
au o.It means relay works Automatically. Suppose, 1036 Total kW 1 5>to<=50 & PT11KV/110V 00000000K 00000000K 0.000M 0.000M
RS 485
1038 Total kVAr 1
Wiring Diagram
we require to works relay MANUAL, Press key to, 5>to<=50 & PT22KV/110V 000000.00M 000000.00M
L1
1040 Total kVA 1
select Manual operation an . 1042 Frequency 1 51>to<=500 & PT11KV/110V 000000.00M 000000.00M 00.00M 00.00M
6. Once Auto or Manual selected, Press ENTER key to 1044 CT Ratio 1 51>to<=500 & PT22KV/110V 0000000.0M 0000000.0M
1046 PT Ratio 1
select relay ON or OFF. 1
501>to<=5000 &PT11KV/110V 0000000.0M 0000000.0M 000.0M 000.0M
1048 THD VLN -L1
on - relay output on 1050 THD VLN -L2 1 5001>to<=9999&PT11KV/110V 00000000M 00000000M 0.000G 0.000G
(K&M (K&M
off- relay output off. But Alarm status ON in display. 1052 THD VLN -L3 1 PT22KV/110V Led ON) Led ON)
1054 THD ILN -L1 1
7. Once relay condition selected,Then Press enter key to 1056 THD ILN -L2 1
L1
L2
L3
Set the ON delay of relay. Set ON delay, by pressing 1058 THD ILN -L3 1
N
1060 MD Fast(Set time/60) 1
, , ,keys until desired value is received. 1
1062 MD Predict(Set time/2)
1064 MD Fast(Set time) 1
TEST CERTIFICATE
8. Once ON delay selected,Then Press enter key to
1066 VLL-L1L2 1
Set the OFF delay of relay. Set OFF delay, by pressing 1068 VLL-L2L3 1
, , ,keys until desired value is received. 1070 VLL-L3L1 1
1
Email : sales@nippenco.com/nippen@nippenco.com
1100 MAX VLN-L1
9. Once OFF delay selected,Then Press enter key to 1
1102 MAX VLN-L2
Tel : 022-29201581/1806/29253164
1116 MAX VLL-L3L1 1 b)Current Circuit and Earth
Or else, Press key twice to return into Run Mode. 1
1118 MIN VLL-L1L2 Parameter 100% 50% 5% Complied
UNO+
1120 MIN VLL-L2L3 1 0
PF Less than 1elect. Complied
Web : www.nippenco.com
1122 MIN VLL-L3L1 1
ADDRESS
AL1
SET-UP SCROLL ENT
1
Alarm status 1138 MIN Hz 1 1. MTE SWS 1.3 class0.1 S.No. 39822 S.No.22904
2000 kWh ace 1 2. YEW 2533E 31 class 0.1 S No 26BU006513
11. In display indicates 1 means alarm relay ON. 1
2002 kWh Export - aee >12 months WARRANTY
0 means alarm relay OFF. 2004 kWh Import - a e 1
Tested by :………… Approved by : ………… Date……………
2006 kVArh - ee 1
9