Escolar Documentos
Profissional Documentos
Cultura Documentos
Building System
Sink - 24 - 20 - 480
Lav/Public - 4 - 15 - 60
Lav/Private - 26 - 2 - 52
Shower - 3 - *30 - 90
_____________
System provided = Two 100 gallon sealed direct vent water heaters with a recovery rate of 223 gph each
(1st hour storage availability of 80 gallons @140 degrees F + 223gph recovery @140 degrees F = 303 gph
available 1st hour usage with 223 gph thereafter per each heater)
Kitchen System
2 Comp Sink - 1 - 10 - 10
Hand Sink - 3 - 5 - 15
Mop Sink - 1 - 15 - 15
Dishwasher - 1 - 50 - 50
Prerinse Sprayer - 1 - 45 - 45
_____________
System provided = one 100 gallon sealed direct vent water heaters with a recovery rate of 223 gph each
(1st hour storage availability of 80 gallons @140 degrees F + 223gph recovery @140 degrees F = 303 gph
available 1st hour usage with 223 gph thereafter)
Kitchen heater could be installed with bypass line to Building System in the event of heater failure.