Escolar Documentos
Profissional Documentos
Cultura Documentos
1
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Overview of FW4570 Training Content
2
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Product Introduction
3
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Shelf Overview
Physical Size:
498mm(W)x1068mm(H)x278mm(D)
Fit to ETSI and 21’’ rack (300 mm
depth and 600mm width)
Contain up to 1 chassis with 1
extension chassis in one ETSI Rack
(2200 x 600 x 300 mm)
Cards dimension:
HOCC 338mmx216.6mmx33mm
SI & IO 338mmx176.6mmx33mm
LC & SC 338mmx216.6mmx25.4mm
4
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Overview
5
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Positioning
FW4570
HOCC LOCC
Product Positioning
Matrix Matrix
Position:
Multi-ring Termination @ N x STM-64, N x STM-16
Carrier grade Ethernet machine
Services: TDM + Ethernet (E1/E3/DS3/STM-n/ Ethernet (FE/GE) with
L2 function and features
6
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Technical Concept Highlights
Future Proof Data and Control Architecture:
High capacity architecture: 15 x 20G + 4x 10G traffic slots
Well established 2.5 Gbit/sec based data infrastructure for backplane traffic
Internal LAN (100 Base-T) for NE internal control
Straight-forward cross-connect architecture
HW Redundancy for all relevant parts of the equipment (system controller, switching fabric,
system clock, fan, electrical interfaces)
Optimal scale of integration: e.g. up to 20G per slot, 126 ports per E1 card
Intelligent "Smart Cards" to offload the system controller from card-related tasks
40G protected, non blocking VC-12, VC-3 switching fabric
Pluggable optics for grey, DWDM, CWDM applications
RPR, GbEth and 10GbEth Layer 2 support
GMPLS capable
Enabled for universal extension shelf concept
7
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Product Application Engineering
8
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Network Topology: Flexible topology
9
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Traditional and New SDH Applications and
Services:
Connection to the Metro Rings
providing Ethernet private LAN Multi-Service Access
UHC layer services
or SDH connectivity
STM-
1/4/16/64
Customer B FW4570 FW4570
Customer A
STM-1/4/16/64
STM-1/4 low speed 100BT
PDH (VC-12, VC-3) GbE
Customer A
Local XC
FW4x70
FW4x70
VC-4
FW4x70
FW4x70
VC-3, VC12
10
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Ethernet over SDH
Services
Services
• Eth, FE, GBE (802.3x/802.1q/802.1p)
• Double tagged VLAN
• Flexible composition of TDM plus
Services
Ethernet
• Quality of Service guarantee
P2P/ /RPR
P2P RPR/ /L2
L2/ /GFP
GFP/ /LCAS
LCAS
P2P • RPR acc. IEEE 802.17
RPR / L2 • Service aggregation
GFP / LCAS • RSTP/MSTP
• Hitless capacity adjustment
SDH
SDH
• High availability
SDH • Full set of protection mechanisms
• Mature and proven technology
• Optimised network configuration
• Advanced TMN capabilities
11
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – Enterprise Leased
Lines
Traditional TDM Leased Lines + Ethernet Leased Lines
Ethernet
TDM
PBX
TDM
TDM STM-n
PBX
Ethernet
Ethernet Ethernet
TDM
PBX
• Point to point connections with TDM interfaces (E1, E3, STM-1) and with
Data Interfaces (10/100baseT, FX, GbE)
• Data interfaces uses now GFP technology, optimizing the transport
• Transparent to the customer
12
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – DSLAM Aggregation
IP DSLAMs aggregation with L2 switch card
FW4x70 GbE
FE
BRAS 1
FW4570
FE
Subscribers
FW4570/ FW4x70
FE FW4570
FE
FW4570
VLANS
GbE BRAS 2
FE
FW4570/ FW4x70
FE
13
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – DSLAM Aggregation
IP DSLAMs aggregation with 10GbE + 6 x GbE/A
GbE
RSTP/ESR
4xGbE (10GbE)
STM-16/64
GbE (1GbE/10GbE)
ESR and P2MP solution Today
STM4/16
Double Play: Each
DSLAM has
GbE 200/250Mbps traffic
14
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – Fixed Mobile Network
Switch
Fixed part of mobile networks HLRVLR
Mobility
S
Switch S
G
BTS/Node B
MSC
STM-16/64
BSC/RNC
BTS/Node B
BSC/RNC
BTS/Node B STM-1/4
BTS/Node B
BTS/Node B
15
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – DSLAM Aggregation
IP DSLAMs aggregation with RPR card RPR ring
FW4570 RPR
FE
Subscribers
GE
FW4570 RPR
GE
VC4-8v ring FW4570 RPR
BRAS 2
GbE
FE
FW4570 RPR
FE
16
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Which Applications Demand Ethernet Services?
Corporate Interconnections Broadband Traffic Aggregation
Multimedia
Internet
P2P
Mobile
• Layer 2 protections like STP/RSTP/MSTP and Link Aggregation can also be used
to assure logical protection and compatibility with the pure data network
Scalability
• Equipments design assure a “pay as you grow” strategy, while still gaining
revenues from the legacy TDM services
Flexibility
18
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
System Components And
Configuration Rules
19
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 – General Block Diagram
20G
Low Order
Q / Q-F2 / Qext Low Order
System Switch
MDO/MDI Switch
Clock
User Channel
System Unit 340G
EOW Interface
VC-3/12
VC-3/12
T4
T3
20G
Low Order
Central VC-4 Switch Low Order
Switch
Controller Switch
VC-3/12
VC-3/12
Packet
SDH Ethernet PDH L2 Fabric
Card Card Card Ethernet
Card
.....
... ... ...
20
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Overall System Architecture
21
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Chassis Slots and Backplane Capacity
PWR PWR
22
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Cross connect capacity
23
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Service Access Capacity of FW4570 Chassis
Service FW4570
STM-64 34
STM-16 136
STM-4/1o 152
10GE 19
GE 152
FE 228
24
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Common Components for FW4570 System
The Core is composed of
2 Fan Trays
1 SI Card
1 SC Card
1 HOCC Card
25
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 – Card Types and Port Density
PDH and SDH cards Data cards
26
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Summary of service cards
Card Name Position (Slot) Cabling Connector Interface Type
LOCC 5,6,7,8
2xSTM-64 2,3,4,5,6,7,8,11,12, From panel of card LC XFP:S-64.2,L-64.2
13,14,15,16,17,28
For slot 24,25,26,27, only the last
port of 2xSTM-64 is applicable
8xSTM-16 2,3,4,5,6,7,8,11,12, 13, From panel of card LC SFP:S-16.1,L-16.1,L-16.2,V16.2,
14,15,16,17,28 CWDM SFP,DWDM SFP
For slot 24,25,26,27, only the last 4
ports of 8xSTM-16 are applicable
8xSTM-4/1 2,3,4,5,6,7,8,11,12,13, From panel of card LC SFP:S-4.1,L-4.1,L-4.2,V4.2,
14,15,16,17,24,25,26,27,28 S-1.1,L-1.1,L-1.2,V1.2,
Electrical STM-1 SFP
8xSTM-1E G1:13,14,15,16,17(P) From the paddle board
G2:24,25,26,27,28(P)
8xSTM-1E G1:30,31,32,33 From panel of card CC4 75OHM STM-1 Elec. interface
Paddle G2:19,20,21,22,
12xE3/DS3 13,14,15(P),16,17 From the paddle board
(W/P)
12xE3/DS3 30,31,32,33 From panel of card CC4 75OHM E3/DS3 interface
Paddle
126xE1 24,25,26(P),27,28 From the paddle board
(W/P)
63xE1 (19,20),(21,22),(29,30),(31,32) From panel of card 2mm 75OHM and 120OHM
Paddle connector configuration by software
27
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Summary of service cards
28
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Card Special Limitation Rules
6GE+4GEFE/A
Only can be equipped in the lower slots.
Maximum numbers should be no more than four.
Slot 4 and slot 16 are not recommended to equip this card.
8xSTM-16
Upper 4 ports is equipped with dedicated DWDM SFP cage with heat sink
for insuring DWDM application even in utmost 45 centigrade ambient
temperature.
Lower 4 ports is still equipped with normal SFP cage.
All 8 ports is allowed to equip DWDM SFPs whereas it is not guaranteed that
DWDM SFPs of lower 4 ports can keep normal operation when under 45
ambient temperature.
29
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Unit Description
30
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Controller module summary
31
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SC (System Controller)
The SC card is the main control unit for FLASHWAVE 4570. It
performs system initialization, configuration, monitoring, and
maintenance.
A Compact Flash (CF) memory card is equipped in the SC card. The
NE database, Management Information Base (MIB), system software,
and configurations are stored in this nonvolatile memory card,
which supports quick recovery in the event of power failure, node
failure, or unit replacement.
32
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SI (System Interface module)
The SI card provides the following main functions:
FLEXR L and FLEXR C R3 access (LCT & NMS connection)
Station clock synchronization
MDI access
MDO access
Alarm output
Alarm Cut Off (ACO)
Alarm Suppress (SUP)
User channel access
Extension shelf management (future release)
SI board is without E1/E2 EOW function, the board can be plug-able
and replaceable.
33
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
HOCC (High order cross connect module)
340G capacity
FLASHWAVE 4570 supports a 340 Gbps high order fabric capacity that can interconnect AU4s between any
SDH and Ethernet port accessing the system.
The switch fabric provides non-blocking switching of traffic at VC-4, VC-4-4c, VC-4-16c, and VC-4-64c levels.
34
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
LOCC (Low order cross connect module)
20G LO capacity per card (VC-12/VC-3 level)
Protected:
20 G LOCC: slot 6 working and slot 7 protection
40 G LOCC: slot 5 and 6 working and slot 7 and 8 protection
The LOCC can be upgraded from 20 G to 40 G without any traffic interruption by adding new LOCC cards to slot 5 and 8.
Unprotected:
20 G LOCC: slot 6
40 G LOCC: slot 5 and 6
Figure 10 below shows the FLASHWAVE 4570 slot arrangement for installation and upgrade of the LOCC card. The arrows are
shown to indicate that the user must start with slots 5 and 6 for the first set of LOCC cards and then be upgraded using slots 6
and 8 for full 40 G capacity
-In 40G LOCC application, two physical 20G LOCC will be treated as one logical 40G LOCC.
-40G LOCC would be failure if one of the two 20G LOCC was failure or both were failure.
-Alarms and card based configuration are still based on each LOCC card. There is no logical group.
-40G LOCC card on other configuration.
35
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2 x STM-64 card
2 x STM-64 ports/ card (XFP based)
: I-64.1, 1310 nm, 2 km, G.652 fiber
: S-64.2b, 1550 nm, 40 km, G.652 fiber
: L-64.2c, 1550 nm, 80 km, G.652 fiber
36
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-16 card
8 x STM-16 ports/ card (SFP based)
Short haul, long haul options:
: S-16.1, 1310 nm, 15 km, G.652 fiber
: L-16.1, 1310 nm, 40 km, G.652 fiber
: L-16.2, 1550 nm, 80 km, G.652/G.654 fiber
: L-16.3, 1550 nm, 80 km, G.653 fiber
Very long, ultra-long haul with OA options:
: V-16.2, 1555.75 nm, 120 km, G.652 fiber with 13 dBm Booster
Optical Amplifier (BOA)
: U-16.2, 1555.75 nm, 160 km, G.652 fiber with 18 dBm BOA
: U-16.2, 1555.75 nm, 180 km, G.652 fiber with 18 dBm BOA and
20 dB Pre- Optical Amplifier (POA)
37
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-16 card
Protection types are as follows:
: 2-fiber MS-SPRing
: 1 + 1 MSP (unidirectional/bidirectional, revertive/non-revertive)
: 1 : N MSP (bidirectional, revertive)
: SNCP (unidirectional/bidirectional)
38
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-4/1 card
8 x STM-4/1 ports/ card
Each port is software configurable (STM-1 or STM-4)
39
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-4/1 card
STM-1 optical SFP options:
- S-1.1, 1310 nm, 15 km, G.652 fiber
- L-1.1, 1310 nm, 40 km, G.652 fiber
- L-1.2, 1550 nm, 80 km, G.652/G.654 fiber
- L-1.3, 1550 nm, 80 km, G.653 fiber
- V-1.2, 1550 nm, 120 km, G.652 fiber
STM-1 electrical SFP options:
- DIN 1.0/2.3 75 Ohm, 100 m, coaxial pair cable
40
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8xSTM-1e (WP)
WP: With Protection function.
: The system supports STM-1e card which has 1:N(N<=4) equipment protection.
: The card provide 8 ports, and it must be installed accompanied by the 8xSTM-1e
IO card.
Note:
: (1)not supporting MSP protection and EPG protection simultaneously
: (2)supporting SNCP and EPG simultaneously
: (3)EOW/DCC+EPG
: (4)timing switching together with STM-1e EPG
41
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8xSTM-1e I/O
The card provides 8xSTM-1e interfaces at 75Ohm impedance with
CC4 Connectors. It also support the 1:N protection function against
the equipment failure on 8xSTM-1e function card.
42
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
12xE3/DS3 (WP)
WP: With Protection function.
: The card provides 12 ports, and it must be installed
accompanied by the 12xE3/DS3 IO card.
: Each port is configurable to either E3 mode or DS3 mode
independently.
43
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
12xE3/DS3 I/O
The card provides 12 E3/DS3 interfaces at 75Ohm impedance. It
also support the 1:N protection function against the equipment
failure on 12xE3/DS3(WP) function card.
44
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
126xE1/R (WP)
WP: With Protection function.
: (1)The system supports 126xE1 card that has 1:N (N<=4) equipment
protection.
: (2)The card supports retiming function.
: (3)The card provides 126 ports, and it must be installed accompanied by
the corresponding IO card (each IO card can provide 63 interface, so one
126xE1 function card needs two IO cards)
45
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
63xE1 I/O
The card provides 63 E1 interfaces, the impedance of 75 Ohm and
120 Ohm can be configured by operator. It also support the 1:N
protection function against the equipment failure on 126xE1(WP)
card.
The connector is based 2mm connector
46
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
1x10GE/T
Key functions of this card are summarized as follows:
GFP encapsulation (ITU-T G.7041/Y.1303)
LCAS supported
VC-4-Xv mapping
SDH and Ethernet performance monitoring and alarms
This module provides one 10Gigabit Ethernet optical interfaces
(XFP). It only supports transparent transmission function. The port
is transparently mapped to a VC-4-Xv via GFP, and LCAS supported.
The physical card bandwidth connected to backplane is 10G.
Each 10 GE optical XFP interface can be equipped with the following XFP modules:
10GBASE-SR/SW Ethernet (850 nm, 300 m, multiple mode fiber)
10GBASE-LR/LW (I-64.1, 1310 nm, 2 km, G.652 fiber)
10GBASE-ER/EW (S-64.2b, 1550 nm, 40 km, G.652 fiber)
10GBASE-ZR/ZL (L-64.2c, 1550 nm, 80 km, G.652 fiber)
47
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Ethernet ptp connections
1 x 10GbE Transparent Card - Block Diagram
4x2.5G LVDS
1x For Working
Backplane
Client
Network
(LAN) transparent (WAN)
VCG
LAN
48
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8xGE/T
Key functions of this card are summarized as follows:
Auto negotiation, flow control, IEEE 802.3, and Ethernet II frame
structure supported by the GE ports
GFP encapsulation (ITU-T G.7041/Y.1303)
LCAS supported on all layers, VC-4, VC-3, VC-12
VC-4-Xv, VC-3-Xv, and VC-12-Xv mapping
SDH and Ethernet performance monitoring and alarms
49
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
6xGE+4FEGE/A
The 6 x GE + 4 x FEGE/A card provides 10 LAN ports and 36 WAN ports as
follows:
Backplane side:
12 GE (1000 Mbps) WAN ports
24 FE (100 Mbps) WAN ports
The 6 x GE + 4 x FEGE/A card supports L2 switching, GFP, higher order virtual
concatenation, LCAS, and LAN/WAN port aggregation. Each GE port supports VC-4
Xv (X = 1 to 7) and VC-3-Xv (X = 1 to 21) bandwidth. Each FE supports VC-3-Xv (X = 1
to 3) and VC-12-Xv (X = 1 to 46) bandwidth.
50
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Ethernet ptmp and mptmp Connections
6 x GbE + 4 FEGE Layer 2 (Aggregation) Card - Block Diagram
#1
SFP
6 x 1000 Base
SX/LX 4x2.5G LVDS
client signals
Aggre- For Working CC (W)
#6 gation/ EoS
SFP
GE Switch GFP-F
4x2.5G LVDS
36xVCG
PHY For
CC (P)
RJ 45 Protection
4 x 10/100/1000
RJ 45
BaseT
client signals Backplane
RJ 45
RJ 45
WAN channels:
Aggregation 12x 1000M WAN
Network
Client WAN
LAN 24x 100M WAN (WAN)
(LAN) Up to 36 VCGs
51
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
6 x GbE + 4 FEGE Layer 2 (Aggregation) Card
- Principle
Virtual Con-
catenation
GFP #1 to VLAN #1 Group 1
GBE 1
SDH (WAN)
GFP #2 to VLAN #2 Virtual Con-
catenation
Group 2
GFP #2 to VLAN #3
Client Network
WAN
(LAN)
LAN (WAN)
Aggregation
52
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
6xGE+4FEGE/A
The main functions supported by this card are as follows:
LAN/WAN ports aggregation
Multicast IGMP snooping
VLAN and double VLAN tagging
ACL based on MAC addresses
Per port rate limiting function: The rate range of each port is from 128 Kbps
to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and the rate provisioning
granularity is 128 Kbps.
Per VLAN rate limiting function: The rate range of each VLAN is from 128 Kbps
to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and the rate provisioning
granularity is 128 Kbps.
Auto negotiation, flow control, IEEE 802.3, and Ethernet II frame structure
supported by the FE/GE ports
GFP encapsulation (ITU-T G.7041/Y.1303)
VC-4-Xv (X = 1...7), VC-3-Xv (X = 1 to 21), and LCAS function supported by the
GE WAN port
VC-3-Xv (X = 1 to 3) or VC-12-Xv (X = 1 to 46), and LCAS function supported by
the FE WAN port
SDH and Ethernet performance monitoring and alarms
GVRP function
MSTP function
53
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2xGE+12xFE/RPR
The 2 x GE + 12 x FE/RPR card provides 14 LAN ports and 2 RPR WAN ports as follows:
Backplane side:
2 RPR WAN ports with 8 x VC-4 bandwidth each
An extra Ethernet connector converter must be used for the FE RJ 45 interfaces to split them
into two separate FE interfaces and connect customer equipment. Each RJ 45 interface has two
LEDs, one to indicate the send/receive status for each FE interface.
The 2 x GE + 12 x FEGE/RPR card supports L2 switching, RPR MAC, GFP, and higher order
virtual concatenation.
54
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2 x GbE + 12 FEGE RPR Card - Block Diagram
SFP 8 x VC 4 east
to the backplane
GE
SFP 1xVCG VC-4-mv
PHY
(m=1..8)
EoS
RJ 45
GFP-F
12 x RPR-
RJ 45
10/100 BaseT MAC
client signals
RJ 45 EoS
(6 physical ifs with 100
12 access)
GFP-F
RJ 45 BaseT
PHY 8 x VC 4 west
RJ 45 to the backplane
RJ 45 1xVCG VC-4-mv
(m=1..8)
RPR / L2 switching
Client WAN
Network
LAN
(LAN) (WAN)
Up to 36 VCGs
55
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2xGE+12xFE/RPR
The main RPR functions supported by this card are as follows:
: Source weighted fairness (class B and class C traffic only)
: 3 service of classes (class A, class B, and class C). Class A traffic can
occupy up to 50% of total RPR bandwidth and only the class A traffic
supports strict order transmission.
: Per port based service rate limiting function: The rate range of each
port is from 128 Kbps to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and
the rate provisioning granularity is 128 Kbps.
: Per VLAN based service rate limiting function: The rate range of each
VLAN is from 128 Kbps to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and
the rate provisioning granularity is 128 Kbps.
: RPR layer protection: steering or wrap protection (user provisional)
: Topology discovery
: Auto negotiation, flow control, IEEE 802.3, and Ethernet II frame
structure supported by the FE/GE ports
: GFP encapsulation (ITU-T G.7041/Y.1303)
: VC-4-Xv, VC-3-Xv, and VC-12-Xv mapping
: SDH and Ethernet performance monitoring and alarms
56
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Guides
57
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Chassis Slots and Backplane Capacity
PWR PWR
58
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Slot and plug-ins guide (Summary)
Interface Card type
STM
STM STM STM E3/
- LO
Ether1 Ether2 - - - D
Slot color Legend Slot Category 4 E1 C OA
*a *b 6 1 1 S
/ C
4 6 E 3
1
HS/LOCC
(Slot 5 – 8)
20G backplane x x x x x x x
HS
(Slot 2/3/4 +Slot11/12)
20G backplane x x x x x x
HS/E
(Slot 13 – 17)
20G backplane x x x x x x x x
HS/E1
(Slot 28)
20G backplane x x x x x x x
HS/E1
(Slot 24 – 27)
10G backplane x *1 *2 x x x x
Common Common
59
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Slot and plug-ins guide (Remarks)
60
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Service port density (Summary)
Service FW4570
STM-64 34
STM-16 136
STM-4/1o 152
10GE 19
GE 152
FE 228
61
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
LOCC configuration Mounting guide
PWR PWR
62
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Scenario #1: Typical MADM64 MSPP
PWR PWR
ADM64:
8x GE/T 8x 8x 8x 8x 8x
H H H H
S S S S S
6x GE+ 4FEGE/A I I I I S S S S I
S T T T T T
O O O O / / / / O
I M M M M M
2x GE+ 12x FE/RPR 1 2 3 4 E E E E 5
|
1 1 1 1
4x 8x STM-4/1 16 IO IO IO IO
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
4x 8x STM-1E w. Protection Fiber Space
4x STM-16 subtending ring 8 8 8 8
6 8x
8 x x x x x 2 2 8x 8x 8x 8x
2x STM-64 Ring S
x G S S S S H H x x S S S S
S E R T S
G + T T T T O O S S T T T T
C 4 P M C
E M M M M C C T T M M M M
F R |
/ E 4 4 4 4 C C M M | | | |
G 1E
T E
/1 /1 /1 /1 64 64 1E 1E 1E 1E
1 2 3 4 5 6 7 8 9
(p)
10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray
FW4570
63
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Scenario #2: Typical MADM64 MSPP
504x E1 1 1 1 1 1 8x
8x STM-1E with protection 63 63 63 63 2 2 2 2 2 63 63 63 63 S
x x x x S 6 6 6 6 6 x x x x T
1x 10GE /T E1 E1 E1 E1 I E E E E E E1 E1 E1 E1 M
IO IO IO IO 1 1 1 1 1 IO IO IO IO
8x GE/T g1 g2 (p) g3 g4 IO
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
8x STM-4/1
Fiber Space
2x GE+12x FE/RPR 8
1 8x
2x STM-16 subtending Rings 8 x 2 2 8x 8x
x S
x S L L H H x x S S
10 R T S
2x STM-64 Ring G T O O O O S S T T
G P M C
E M C C C C T T M M
E R |
/ 4 C C C C M M | |
/ 1E
T /1 64 64 16 1E
1 2
T3 4 5 6 7 8 9 10 11 12 13 14
(p)
15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray
FW4570
64
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Scenario #3: Typical ADM64 MSPP
1512x E1 1 1 1 1 1 8x
(with 2 extension shelves) 63 63 63 63 2 2 2 2 2 63 63 63 63 S
8x STM-1E with protection x x x x S 6 6 6 6 6 x x x x T
E1 E1 E1 E1 I E E E E E E1 E1 E1 E1 M
2xGE + 12xFE /RPR IO IO IO IO 1 1 1 1 1 IO IO IO IO
g1 g2 (p) g3 g4 IO
4xSTM-4 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
65
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
W
R
SC
P
8
2
W
R
P
XCT2 w. LC
7
XCT 1 w. LC
6
Fan Tray
5
63xE1 (P)
4
63xE1 #4 (W)
Configuration Scenario #3: Typical ADM64 MSPP
FW4370
63xE1 #3 (W)
3
63xE1 #2 (W)
2
63xE1 #1 (W)
1
20
63 x E1 I/O #4
19
63 x E1 I/O #3
63 x E1 I/O #1
17
504x E1(with 2 extension shelves)
W
R
SC
P
8
2
2xFW4370 (as extension shelf)
W
R
P
XCT2 w. LC
7
XCT 1 w. LC
Fan Tray
5
63xE1 (P)
4
63xE1 #4 (W)
63xE1 #3 (W)
FW4370
63xE1 #2 (W)
2
63xE1 #1 (W)
1
20
63 x E1 I/O #4
19
63 x E1 I/O #3
SDH/FW4570/022-02
63 x E1 I/O #2
18
63 x E1 I/O #1
17
66
Configuration Scenario #4:
PWR PWR
4xS64.1 8 8 8 8
2
x x x x
x
16xS16.1 I I I I S S S S I I I I I
S S
O O O O T T T T O O O O O
12xS4.1 I T
1 2 3 4 M M M M 5 6 7 8 9
M
4 4 4 4
24xS1.1 64
/1
19 20 21 22 23 24
/1
25
/1
27
/1
27 28 29 30 31 32 33
4x1000BaseTx Fiber Space
8
8 2 8x 8x
x
x H H x S S
S S
S G O O S T T
T C
C E C C T M M
M
/ C C M | |
4
T 64 16 16
1 2 3 4
/1
5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray
FW4570
67
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Synchronization
The system interface panel of FW4570 interfaces:
External clock source (T3): 2 input port, framed 2048kbit/s or
unframed 2048 kHz (75/120 Ohm)
Synchronize output (T4): 2 output port, framed 2048kbit/s or
unframed 2048 kHz (75W/120W)
Note:
The maximum number of total selected timing source per NE is 8. Any port of PDH or SDH
card can be used as candidate timing reference, but for each card, maximum 4 ports can
be selected.
68
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Protection Mechanism
69
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 Protection Overview
• Protection Architectures (How they work):
• 1+1
• 1:1
• 1:N
• Protection Types (How they are applied):
• Equipment/Card protection
• Traffic protection
• Path protection (SNCP)
• Section protection (1+1 & 1:N MSP, MS-SPRing)
• DNI/ DRI
• Packet protection (via RPR)
70
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Network Protection
SDH Layer Protection
STM-64: 2F/4F MS-SPRING, MSP 1+1, SNCP/NI HO/LO
STM-16: 2F/4F MS-SPRING, MSP 1+1, SNCP/NI HO/LO
STM-4: 2F MS-SPRING, MSP 1+1, SNCP/NI HO/LO
STM-1: MSP 1+1, SNCP/NI HO/LO
STM-1E: MSP 1+1(MSP and EPG can not be configured
simultaneously), Hardware 1:4 protection, SNCP/NI HO/LO
Support 1:N bidirectional revertive MSP (unidirectional 1:N MSP is
not supported)
Ethernet Layer Protection
GFP (Generic Framing Procedure) and LCAS (Link Capacity
Adjustment Scheme)
RSTP/MSTP (Rapid/Multi Spanning Tree Protocol) per VLAN, or per
VLAN group
RPR steering protection based on 802.17 MAC
71
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Equipment Protection
HOCC-High Order Cross-Connect Card
1+1 protection with timing protection together
STM-1E Card
1:4 protection
E3/DS3 Card
1:4 protection
E1 Card
1:4 protection
72
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SNCP – Normal operation
Example (only one direction is shown):
19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
4
Fiber Space Tail end select
PWR IO
S H H H H H H H
H
O
H
O
H H
H H
S S
H
S
H
S
H
S
S SDH cloud
C S S S S S S S S S C
C C / / / / / H H H H H
C C E E E E E I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1 Pat 1 2 3 4 E E E E E 5 6 7 8 9
1 2 3 4 5 6 7 8
Fiber Duct hA 1 1 1 1 1
Fan Tray 19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
Fan Tray 4
Fiber Space
Pat
Air Filter Tray
h B
Head-end
broadcast S H H H H H H H
H H
H H
H H H H H
S
O O S S S S S
C S S S S S S S S S C
C C / / / / /
C C E E E E E
1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1
1 2 3 4 5 6 7 8
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray
73
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SNCP – Failure event
Example (only one direction is shown):
H H H H H
I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 E E E E E 5 6 7 8 9
1 1 1 1 1
19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
4
Fiber Space Tail end select
PWR IO
S H H H H H H H
H
O
H
O
H H
H H
S S
H
S
H
S
H
S
S SDH cloud
C S S S S S S S S S C
C C / / / / / H H H H H
C C E E E E E I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1 Pat 1 2 3 4 E E E E E 5 6 7 8 9
1 2 3 4 5 6 7 8
Fiber Duct hA 1 1 1 1 1
Fan Tray 19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
Fan Tray 4
Fiber Space
Pat
Air Filter Tray
h B
Head-end
broadcast S H H H H H H H
H H
H H
H H H H H
S
O O S S S S S
C S S S S S S S S S C
C C / / / / /
C C E E E E E
1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1
1 2 3 4 5 6 7 8
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray
74
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
1+1 MSP (for all STM-N)
MSP 1+1 can be formed from any two STM-N ports regardless of
whether it's on the same card, different cards, or non-adjacent slots
(fully flexible)
Non-Revertive/ Revertive mode supported & Uni/ Bi switching can be
configured
Example: Working port
Protection port
1+1 MSP
75
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
1:N MSP for traffic and port protection
Traffic protection
1:N MSP (N ≤ 14)
1:3 port
protection,
. Extra traffic can be transmitted on the protection path 1:4 port
protection
Working port
Protection port
Important: Since card protection here is
based on MSP, client equipment must
FW4570
support MSP also! 1:N MSP on both ends!
CLU Slot
CLU Slot
PDH Slot
PDH Slot
PDH Slot
PDH Slot
LSU Slot
LSU Slot
LSU Slot
LSU Slot
LSU Slot
LSU Slot
LSU Slot
LSU Slot
201
215
214
203
204
206
207
209
210
211
202
205
208
212
213
Backplane
Revertive/ Non-revertive
311
312
313
301
302
303
308
309
310
304
305
306
307
314
76
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Mixed protection schemes
Example:
Working port
MS-SPRING: Up to 16 nodes
Protection port
wes
t 1+1 MSP,
eas
t 2-F MS-SPRing and
4-F MS-SPRing
at the same time
2-F MS-SPRing
we we ea east
st st st
4-F MS-SPRing
77
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
E1 Card 1:4 Protection
PWR PWR
Provide up to 1 group 1:4 E1 card
protection in FW4570 system, 1 1 1 1 1
63 63 63 63 63 63 63 63
shown on the right figure 2 2 2 2 2
E1 E1 E1 E1 E1 E1 E1 E1 I
S 6 6 6 6 6
IO IO IO IO IO IO IO IO O
Protection Pair: I E E E E E
9
1 1 1 1 1
g1 g1 g2 g2 g3 g3 g4 g4
Slot 26 is the dedicated protected g1 g2 (p) g3 g4
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
slot, universal function card for
Fiber Space
both working and protection..
Process IO Pairs
H H H H H H H
S H H H H H H H H H S
Slot 19 (63 E1 IO), Slot 20 (63 E1 IO) C S S S S S S S
O O
S S
S S S S S
C
-- Slot 24 (126 E1) C C / / / / /
C C E E E E E
Slot 21 (63 E1 IO), Slot 22 (63 E1 IO)
-- Slot 25 (126 E1) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Slot 29 (63 E1 IO), Slot 30 (63 E1 IO) Fan Tray
-- Slot 27 (126 E1) Fan Tray
Slot 31 (63 E1 IO), Slot 32 (63 E1 IO) Air Filter Tray
-- Slot 28 (126 E1) FW4570
78
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
E3/DS3 Card 1:4 Protection
PWR PWR
Provide up to 1 group 1:4 12x
E3/DS3 card protection in FW4570 E3 E3 E3 E3
H H H H H
system, shown on the right figure / / / /
I I I I S S S S S I
S DS DS DS DS
O O O O / / / / / O
I 3 3 3 3
Protection Pair: 1 2 3 4 E E E E E 5
IO IO IO IO
1 1 1 1 1
Slot 15 is the dedicated protected g1 g2 g3 g4
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
slot, universal function card for
Fiber Space
both working and protection.
E3 E3 E3 E3 E3
Process IO Pairs
H H / / / / /
S H H H H H H H H H S
Slot 30 (12 E3/DS3 IO) -- Slot 13 C S S S S S S S
O O
S S
DSDSDSDSDS
C
(12 E3/DS3) C C 3 3 3 3 3
C C
- Slot 31 (12 E3/DS3 IO) -- Slot 14 g1 g2 (p) g3 g4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
(12 E3/DS3)
Fiber Duct
- Slot 32 (12 E3/DS3 IO) -- Slot 16 FanFanTrayTray
(12 E3/DS3) Fan Tray
- Slot 33 (12 E3/DS3 IO) -- Slot 17 Air Filter Tray
(12 E3/DS3) FW4570
79
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
STM-1E Card 1:4 Protection
Provide up to 2 groups 1:4 8xSTM-1 el. card
PWR PWR
protection in FW4570 system, shown on the
right figure
S S S S S S S S S S S S S
Protection Pair for group 1: T T T T T T T T T T T T T
I
Slot 17 is the dedicated protected slot for M M M M S M M M M M M M M M
O
STM-1E, universal function card for both 1 1 1 1 I | | | | | 1 1 1 1
5
working and protection. IO IO IO IO 1E 1E 1E 1E 1E IO IO IO IO
Process IO Pairs G1 G2 G3 G4 G1G2G3G4 (p) g1 g2 g3 g4
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
Slot 30 (8 STM-1E IO) -- Slot 13 (8 STM-1E)
Fiber Space
- Slot 31 (8 STM-1E IO) -- Slot 14 (8 STM-1E)
- Slot 32 (8 STM-1E IO) -- Slot 15 (8 STM-1E) S S S S S
- Slot 33 (8 STM-1E IO) -- Slot 16 (8 STM-1E) H H T T T T T
S H H H H H H H H H S
Protection Pair for group 2:
O O M M M M M
C S S S S S S S S S C
C C | | | | |
Slot 28 is the dedicated protected slot for
C C 1E 1E 1E 1E 1E
STM-1E, universal function card for both
g1 g2 g3 g4 (p)
working and protection.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Process IO Pairs Fiber Duct
Slot 19 (8 STM-1E IO) -- Slot 24 (8 STM-1E) FAN Tray
- Slot 20 (8 STM-1E IO) -- Slot 25 (8 STM-1E) FAN Tray
- Slot 21 (8 STM-1E IO) -- Slot 26 (8 STM-1E) Air Filter Tray
- Slot 22 (8 STM-1E IO) -- Slot 27 (8 STM-1E)
FW4570
80
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Mixed Protection 1
PWR PWR
FW4570 can support 4 protection S
S
S 1 1 1 S E3 T
groups simultaneously. T 63 63 63 63
T 2 2 2 T / M
M E1 E1 E1 E1
S M 6 6 6 M DS 1
1 IO IO IO IO
252 E1 (1:2 P) I | E E E | 3 E
E
1E 1 1 1 1E IO IO
8 STM-1E (1:1 P) IO g2 g2 g3 g3
G1 g2 (p) g3 (p) g2 g4
G1
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
8 STM-1E (1:1 P)
Fiber Space
12 E3 (1:1 P)
E3 E3 S S
L L
H H / / T T
S H H H H O O H H H S
O O DSDS M M
C S S S S C C S S S C
C C 3 3 | |
C C
C C 1E 1E
g2 (p) g4 (p)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filer Tray
FW4570
81
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Mixed Protection 2
PWR PWR
FW4570 can support 4 protection S
S 1 1 1 S E3 E3 E3
groups simultaneously. T 63 63
T 2 2 2 T
63 63
/ / /
M E1 E1 E1 E1
S M 6 6 6 M DS DS DS
1 IO IO IO IO
252 E1 (1:2 P) I | E E E | 3 3 3
E
1E 1 1 1 1E IO IO IO
8 STM-1E (1:1 P) IO g2 g2 g3 g3
G1 g2 (p) g3 (p) g2 g3 g4
G1
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
36 E3 (1:3 P)
Fiber Space
E3E3 E3 E3
L L
H H H / / / /
S H H H H O O H H H S
O O S DSDSDSDS
C S S S S C C S S S C
C C / 3 3 3 3
C C
C C E
g2 (p) g3 g4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filer Tray
FW4570
82
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Basic Operation and Maintenance
83
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Operating & Maintenance Features:
NMS Operation
Few categories as described above:
84
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Maintenance task
Features for Maintenance task: Features for Operating task:
85
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Loopback
Traffic will be interrupted when loopback is active
Interface port
FW4570
The loopback feature is available for all SDH and PDH port + Optical interface of GE
86
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Laser Safety shutdown
• ALS compliant to ITU-T G.783 ITU G.664
• ALS features: Enabled/ Disabled Avoid direct eye contact
• Supported for all SDH interface port (STM-1/4/16/64) to laser output
(Class 1 laser warning)
Time
87
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
LED test/ ACO/ SUP
LED color:
1 PWR (green)
1 FAULT (red) Alarm Cut Off:
Alarm Suppress:
1 CR (red) After Press ACO, office alarms
Visible alarms is not reported
1 MJ (orange) (Audible) will be cut
1 MN (yellow)
88
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
PRBS Feature
PRBS (pseudo-random binary sequence) is used to measure the bit-error performance of digital
systems by directly comparing a received pseudo-random test pattern with a locally generated
test pattern identical to the transmitted test pattern
Recommendations
Bit Recommendations
corresponding to Bit rate Test
rates corresponding to
digital line section/line tolerance Pattern PRBS is supported for
(kbps) multiplex system
system E1/E3
215 – 1,
1544 G.733 G.911, G.951, G.955 ± 50 · 10–6
220 – 1
220 – 1
Note:
Activating PRBS test can cause service interruption
89
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Overall Fault Management Feature/ Mechanism
Understanding overall system features
Fault Management
By software:
LCT/ NMS Detection time Clearance time
(Def: 2s) (Def: 10s)
For all common alarms 0: Immediately report/ clear
(Alarms is not inhibited)
Enable alarms type
- RS-LOF/ TU-LOM/ TU-LOP/ AIS/ RDI/ TIM/ SLM
90
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Performance Monitoring
Current and previous values: 15 minute period and 24 hour period
Historical values: maximum 16 records for 15 minute periods, 1 record for 24 hour period
PM Monitoring options:
Performance Monitoring
Enabled/ Disabled per
card/ port base
SDH/PDH Ethernet
Functions:
•PM (processing and reporting) of parameters.
•Inquiry of current and historical values of the parameters.
•Supervision of parameter thresholds (Not for Ethernet)
91
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Performance Monitoring Parameter
Depending on the supported protocols of the transponder, the following performance monitoring
parameters are supported:
SDH: supports the following regenerator section and multiplex section performance parameters, counted
according to G.829:
Background Block Error (BBE)
Consecutive Severely Errored Second (CSES)
Errored Second (ES)
Out of Frame Second (OFS)
Point Justification Count Negative (PJCN)
Point Justification Count Positive (PJCP)
Severely Errored Second (SES)
Unavailable Second (UAS)
No far-end PM parameters are defined for the SDH Regenerator Section.
Ethernet performance monitoring supports the following parameters:
Received Total Byte
Received Total/Good/Bad/Unicast/Multicast/Broadcast/Fragment Packet
Received Dropped/Undersize/Oversize Good Packet
Receive Good Pause Packet
92
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only