FLASHWAVE FW4570

ENGINEERING & MAINTENANCE

1
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Overview of FW4570 Training Content

FW4570 product Introduction


Product Application Engineering
System Components and Configuration Rules
Unit Description
Configuration Guides
Protection Mechanism
Basic Operation and Maintenance

2
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Product Introduction

3
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Shelf Overview

 Physical Size:
498mm(W)x1068mm(H)x278mm(D)
 Fit to ETSI and 21’’ rack (300 mm
depth and 600mm width)
 Contain up to 1 chassis with 1
extension chassis in one ETSI Rack
(2200 x 600 x 300 mm)
 Cards dimension:
HOCC 338mmx216.6mmx33mm
SI & IO 338mmx176.6mmx33mm
LC & SC 338mmx216.6mmx25.4mm

4
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Overview

• Multi Service Platform for PDH, SDH, and Data Integration


• 340G@VC-4 and 40G@VC-12 / VC-3 Switching Granularity
• Packet fabrics (L2 Eth Switch & RPR)
• Extended ptp and L2 Ethernet functionalities
• Extensive protection features (HW, SNCP, MSP, 2F/4F MS-SPRing,
DNI)
• High density 10G systems.

5
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Positioning
FW4570
HOCC LOCC
Product Positioning
Matrix Matrix

340G 40/20G High end 10G Systems, Backbone core switching

 Position:
 Multi-ring Termination @ N x STM-64, N x STM-16
 Carrier grade Ethernet machine
 Services: TDM + Ethernet (E1/E3/DS3/STM-n/ Ethernet (FE/GE) with
L2 function and features

6
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Technical Concept Highlights
 Future Proof Data and Control Architecture:
 High capacity architecture: 15 x 20G + 4x 10G traffic slots
 Well established 2.5 Gbit/sec based data infrastructure for backplane traffic
 Internal LAN (100 Base-T) for NE internal control
 Straight-forward cross-connect architecture

 HW Redundancy for all relevant parts of the equipment (system controller, switching fabric,
system clock, fan, electrical interfaces)
 Optimal scale of integration: e.g. up to 20G per slot, 126 ports per E1 card
 Intelligent "Smart Cards" to offload the system controller from card-related tasks
 40G protected, non blocking VC-12, VC-3 switching fabric
 Pluggable optics for grey, DWDM, CWDM applications
 RPR, GbEth and 10GbEth Layer 2 support
 GMPLS capable
 Enabled for universal extension shelf concept

7
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Product Application Engineering

8
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Network Topology: Flexible topology

FLASHWAVE 4570 can be used in any kind of


network topology, including:
•Terminal-to-terminal topologies
•Linear topologies with add/drop
function (Chains)
•Ring topologies with add/drop
function
•Meshed networks

9
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Traditional and New SDH Applications and
Services:
Connection to the Metro Rings
providing Ethernet private LAN Multi-Service Access
UHC layer services
or SDH connectivity
STM-
1/4/16/64
Customer B FW4570 FW4570

Customer A
STM-1/4/16/64
STM-1/4 low speed 100BT
PDH (VC-12, VC-3) GbE
Customer A

Ring Mux/Partial Ring Extensions/Overlays


Meshed Networks

Local XC
FW4x70
FW4x70

VC-4

FW4x70
FW4x70
VC-3, VC12

10
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 - Ethernet over SDH

Services
Services
• Eth, FE, GBE (802.3x/802.1q/802.1p)
• Double tagged VLAN
• Flexible composition of TDM plus
Services
Ethernet
• Quality of Service guarantee

P2P/ /RPR
P2P RPR/ /L2
L2/ /GFP
GFP/ /LCAS
LCAS
P2P • RPR acc. IEEE 802.17
RPR / L2 • Service aggregation
GFP / LCAS • RSTP/MSTP
• Hitless capacity adjustment

SDH
SDH
• High availability
SDH • Full set of protection mechanisms
• Mature and proven technology
• Optimised network configuration
• Advanced TMN capabilities

11
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – Enterprise Leased
Lines
Traditional TDM Leased Lines + Ethernet Leased Lines

STP SS7 Switch


Internet
PSTN / ISDN

Ethernet
TDM
PBX
TDM

TDM STM-n
PBX

Ethernet
Ethernet Ethernet
TDM

PBX

• Point to point connections with TDM interfaces (E1, E3, STM-1) and with
Data Interfaces (10/100baseT, FX, GbE)
• Data interfaces uses now GFP technology, optimizing the transport
• Transparent to the customer

12
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – DSLAM Aggregation
IP DSLAMs aggregation with L2 switch card

FW4x70 GbE
FE
BRAS 1

FW4570
FE
Subscribers

FW4570/ FW4x70
FE FW4570

FE
FW4570

VLANS
GbE BRAS 2
FE
FW4570/ FW4x70

FE

13
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – DSLAM Aggregation
IP DSLAMs aggregation with 10GbE + 6 x GbE/A

GbE
RSTP/ESR
4xGbE (10GbE)

STM-16/64
GbE (1GbE/10GbE)
ESR and P2MP solution Today
STM4/16
Double Play: Each
DSLAM has
GbE 200/250Mbps traffic

Triple Play: Each DSLAM


has 400/500Mbps traffic

25k/35k 50/80 DSLAMs 7/12 PoPs (FW4570)


Subscribers

14
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – Fixed Mobile Network
Switch
Fixed part of mobile networks HLRVLR
Mobility

S
Switch S
G

BTS/Node B
MSC
STM-16/64

BSC/RNC
BTS/Node B

BSC/RNC

BTS/Node B STM-1/4

BTS/Node B
BTS/Node B

15
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Carriers’ Applications – DSLAM Aggregation
IP DSLAMs aggregation with RPR card RPR ring

FW4570 RPR GbE


GE
BRAS 1

FW4570 RPR
FE
Subscribers

GE

FW4570 RPR
GE
VC4-8v ring FW4570 RPR

BRAS 2
GbE
FE
FW4570 RPR

FE

16
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Which Applications Demand Ethernet Services?
Corporate Interconnections Broadband Traffic Aggregation

Traffic Differentiation “All in one”


IP-TV

Multimedia

Internet
P2P

Mobile

17 Fujitsu and Fujitsu Customer Use Only


SDH/FW4570/022-02 Traffic Differentiation
Ethernet over SDH: The Best Solution for Your
Network
Carrier Class Availability
• Known Layer 1 protection (BSHR, MSP, SNC) can be used together with the
Ethernet services to guarantee Carrier Class 50ms protection switching

• Layer 2 protections like STP/RSTP/MSTP and Link Aggregation can also be used
to assure logical protection and compatibility with the pure data network

Scalability
• Equipments design assure a “pay as you grow” strategy, while still gaining
revenues from the legacy TDM services

Flexibility

• Ring, chain, point to point or meshed topologies can be build

• Separation of the traffic can be logically or physically done, using same


infrastructure

18
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
System Components And
Configuration Rules

19
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 – General Block Diagram
20G
Low Order
Q / Q-F2 / Qext Low Order
System Switch
MDO/MDI Switch
Clock
User Channel
System Unit 340G
EOW Interface
VC-3/12
VC-3/12
T4
T3

20G
Low Order
Central VC-4 Switch Low Order
Switch
Controller Switch

VC-3/12
VC-3/12

Packet
SDH Ethernet PDH L2 Fabric
Card Card Card Ethernet
Card
.....
... ... ...

20
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Overall System Architecture

21
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Chassis Slots and Backplane Capacity
PWR PWR

H H H H H Equipment Core slots


I I I I S S S S S I I I I I
S HS slots, 20G & LOCC slots
O O O O / / / / / O O O O O
I
1 2 3 4 E E E E E 5 6 7 8 9
1 1 1 1 1 HS slots, 20G backplane w.DS3/STM-1E
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

Fiber Space HS slots, 20G backplane

HS slots, 10G backplane w. E1 STM-1E


H H H H H H H
S H H H H H H H H H S HS slots, 20G backplane w. E1 STM-1E
O O S S S S S
C S S S/LOCC
S S S S S S C
C C / / / / /
IO slots
C C E E E E E
Note: The small italic number indicates slot number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
HS =High speed slot (20G)
Fiber Duct HS/E =HS & also support DS3/STM-1E
Fan Tray HS/E1 =10G High Speed & E1 STM-1E
Fan Tray HOCC =High Order Cross-Connect slot
SC =System Controller slot
Air Filter Tray PWR =Power Supply slot, fixed with chassis
FW4570

22
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Cross connect capacity

High Order cross connect: VC4


 HO cross connect: 340G

LO cross connect: 20G (VC12/VC3)


 LO cross connect: 40G
maximum total capacity: 2 x 20G(W) + 2 x 20G(P)

23
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Service Access Capacity of FW4570 Chassis
Service FW4570

STM-64 34

STM-16 136

STM-4/1o 152

STM-1 E 64 (with 1:4 card protection)

10GE 19

GE 152

FE 228

38 (2 channels in 8xGE/T card can be


1G FC
configured as 1G FC)

E3/DS3 48 (with 1:4 card protection)

E1 504 (with 1:4 card protection)

24
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Common Components for FW4570 System
The Core is composed of

 1 Chassis (Backplane included)

 2 Fan Trays

 2 Power Modules (fixed into Chassis)

 1 SI Card

 1 SC Card

 1 HOCC Card

25
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 – Card Types and Port Density
PDH and SDH cards Data cards

 STM-256 (Architecture ready)


 8xGE/T(2 ports supporting 1G FC)
 STM-64, 2 ports/card using XFP
 6xGE + 4xFEGE/A
 STM-16, 8 ports/card using grey,
 1x10GE/T
 STM-4/1O, 8 ports/card
 1x10GE+10xGE/L2
 STM-1E, 8 ports/card
 2xGE+12xFE RPR
 E3/DS3, 12 ports/card
 E1, 126 ports/card
 Optical Amplifiers

26
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Summary of service cards
Card Name Position (Slot) Cabling Connector Interface Type
LOCC 5,6,7,8
2xSTM-64 2,3,4,5,6,7,8,11,12, From panel of card LC XFP:S-64.2,L-64.2
13,14,15,16,17,28
For slot 24,25,26,27, only the last
port of 2xSTM-64 is applicable
8xSTM-16 2,3,4,5,6,7,8,11,12, 13, From panel of card LC SFP:S-16.1,L-16.1,L-16.2,V16.2,
14,15,16,17,28 CWDM SFP,DWDM SFP
For slot 24,25,26,27, only the last 4
ports of 8xSTM-16 are applicable
8xSTM-4/1 2,3,4,5,6,7,8,11,12,13, From panel of card LC SFP:S-4.1,L-4.1,L-4.2,V4.2,
14,15,16,17,24,25,26,27,28 S-1.1,L-1.1,L-1.2,V1.2,
Electrical STM-1 SFP
8xSTM-1E G1:13,14,15,16,17(P) From the paddle board
G2:24,25,26,27,28(P)
8xSTM-1E G1:30,31,32,33 From panel of card CC4 75OHM STM-1 Elec. interface
Paddle G2:19,20,21,22,
12xE3/DS3 13,14,15(P),16,17 From the paddle board
(W/P)
12xE3/DS3 30,31,32,33 From panel of card CC4 75OHM E3/DS3 interface
Paddle
126xE1 24,25,26(P),27,28 From the paddle board
(W/P)
63xE1 (19,20),(21,22),(29,30),(31,32) From panel of card 2mm 75OHM and 120OHM
Paddle connector configuration by software

27
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Summary of service cards

Card Name Position (Slot) Cabling Connect Interface Type


or
1x10GE/T 2,3,4,5,6,7,8,11,12, 13,14,15, From panel of card LC 10 GE XFP
16,17,24,25,26,27,28
8xGE/T 2,3,4,5,6,7,8,11,12, 13,14,15, From panel of card LC GE-SX(850nm),GE-LX(1310nm),
16,17,24,25,26,27,28 GE-LH(1310),GE-LZ(1550nm),
Electrical GE SFP
6xGE+4xFEGE/A 2,3,5,6,7,8,11,12, 13,14,15,17, From panel of card LC GE-SX(850nm),GE-LX(1310nm),
only maximum 4 cards is allowed GE-LH(1310),GE-LZ(1550nm),
to be equipped in one FW4570. Electrical GE SFP
2xGE+12xFE 2,3,4,5,6,7,8,11,12, 13,14,15, From panel of card GE:LC GE-SX(850nm),GE-LX(1310nm),
RPR 16,17,24,25,26,27,28 FE:RJ45 GE-LH(1310),GE-LZ(1550nm),
10/100 BASE-T, Electrical GE SFP
OA 2,3,4,5,6,7,8,11,12, 13,14,15, From panel of card LC Booster OA (13dBm)
16,17,24,25,26,27,28 Booster OA (15dBm)
Booster OA (18dBm)
Pre_Amp(20dB 1555.75nm)

28
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Card Special Limitation Rules
 6GE+4GEFE/A
Only can be equipped in the lower slots.
Maximum numbers should be no more than four.
Slot 4 and slot 16 are not recommended to equip this card.

 8xSTM-16
Upper 4 ports is equipped with dedicated DWDM SFP cage with heat sink
for insuring DWDM application even in utmost 45 centigrade ambient
temperature.
Lower 4 ports is still equipped with normal SFP cage.
All 8 ports is allowed to equip DWDM SFPs whereas it is not guaranteed that
DWDM SFPs of lower 4 ports can keep normal operation when under 45
ambient temperature.

29
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Unit Description

30
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Controller module summary

Card name Usage Interfaces Buttons LEDs

SC NE configuration 1 DB 9 (RS 232) 1 RESET 1 ACT (green)


1 PWR (green)
1 FAULT (red)
1 CF (green)

SI NE management 19 RJ 45 1 LED TEST 1 PWR (green)


1 ACO 1 FAULT (red)
1 SUP 1 CR (red)
1 MJ (orange)
1 MN (yellow)

SI-E NE management 20 RJ 45 1 LED TEST 1 PWR (green)


1 ACO 1 FAULT (red)
1 SUP 1 CR (red)
1 MJ (orange)
1 MN (yellow)

31
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SC (System Controller)
 The SC card is the main control unit for FLASHWAVE 4570. It
performs system initialization, configuration, monitoring, and
maintenance.
 A Compact Flash (CF) memory card is equipped in the SC card. The
NE database, Management Information Base (MIB), system software,
and configurations are stored in this nonvolatile memory card,
which supports quick recovery in the event of power failure, node
failure, or unit replacement.

32
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SI (System Interface module)
 The SI card provides the following main functions:
 FLEXR L and FLEXR C R3 access (LCT & NMS connection)
 Station clock synchronization
 MDI access
 MDO access
 Alarm output
 Alarm Cut Off (ACO)
 Alarm Suppress (SUP)
 User channel access
 Extension shelf management (future release)
 SI board is without E1/E2 EOW function, the board can be plug-able
and replaceable.

33
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
HOCC (High order cross connect module)
 340G capacity
FLASHWAVE 4570 supports a 340 Gbps high order fabric capacity that can interconnect AU4s between any
SDH and Ethernet port accessing the system.

The switch fabric provides non-blocking switching of traffic at VC-4, VC-4-4c, VC-4-16c, and VC-4-64c levels.

-Hitless switching (no error when switching)


-1+1 unit redundancy
-Mounted in Slot 9/10

34
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
LOCC (Low order cross connect module)
 20G LO capacity per card (VC-12/VC-3 level)
Protected:
20 G LOCC: slot 6 working and slot 7 protection
40 G LOCC: slot 5 and 6 working and slot 7 and 8 protection
The LOCC can be upgraded from 20 G to 40 G without any traffic interruption by adding new LOCC cards to slot 5 and 8.

Unprotected:
20 G LOCC: slot 6
40 G LOCC: slot 5 and 6
Figure 10 below shows the FLASHWAVE 4570 slot arrangement for installation and upgrade of the LOCC card. The arrows are
shown to indicate that the user must start with slots 5 and 6 for the first set of LOCC cards and then be upgraded using slots 6
and 8 for full 40 G capacity

-In 40G LOCC application, two physical 20G LOCC will be treated as one logical 40G LOCC.
-40G LOCC would be failure if one of the two 20G LOCC was failure or both were failure.
-Alarms and card based configuration are still based on each LOCC card. There is no logical group.
-40G LOCC card on other configuration.

35
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2 x STM-64 card
 2 x STM-64 ports/ card (XFP based)
: I-64.1, 1310 nm, 2 km, G.652 fiber
: S-64.2b, 1550 nm, 40 km, G.652 fiber
: L-64.2c, 1550 nm, 80 km, G.652 fiber

 Support 1+1MSP/ 1:N MSP/ SNCP/ 2F-BLSR


 Any pair of ports can be chosen to create an MSP or MS-SPRing
group

36
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-16 card
 8 x STM-16 ports/ card (SFP based)
 Short haul, long haul options:
: S-16.1, 1310 nm, 15 km, G.652 fiber
: L-16.1, 1310 nm, 40 km, G.652 fiber
: L-16.2, 1550 nm, 80 km, G.652/G.654 fiber
: L-16.3, 1550 nm, 80 km, G.653 fiber
 Very long, ultra-long haul with OA options:
: V-16.2, 1555.75 nm, 120 km, G.652 fiber with 13 dBm Booster
Optical Amplifier (BOA)
: U-16.2, 1555.75 nm, 160 km, G.652 fiber with 18 dBm BOA
: U-16.2, 1555.75 nm, 180 km, G.652 fiber with 18 dBm BOA and
20 dB Pre- Optical Amplifier (POA)

37
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-16 card
 Protection types are as follows:
: 2-fiber MS-SPRing
: 1 + 1 MSP (unidirectional/bidirectional, revertive/non-revertive)
: 1 : N MSP (bidirectional, revertive)
: SNCP (unidirectional/bidirectional)

 No limitation for port pairing for protection purpose within the


same card

38
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-4/1 card
 8 x STM-4/1 ports/ card
 Each port is software configurable (STM-1 or STM-4)

 The supported transmission protection types on the 8 x STM-16 card are as


follows:
: 2-fiber MS-SPRing (Applicable for STM-4 only)
: 1 + 1 MSP (unidirectional/bidirectional, revertive/non-revertive)
: 1 : N MSP (bidirectional, revertive)
: SNCP (unidirectional/bidirectional)
The supported SFP modules are as follows:
 STM-4 options:
- S-4.1, 1310 nm, 15 km, G.652 fiber
- L-4.1, 1310 nm, 40 km, G.652 fiber
- L-4.2, 1550 nm, 80 km, G.652/G.654 fiber
- L-4.3, 1550 nm, 80 km, G.653 fiber
- V-4.2, 1550 nm, 120 km, G.652 fiber

39
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8 x STM-4/1 card
 STM-1 optical SFP options:
- S-1.1, 1310 nm, 15 km, G.652 fiber
- L-1.1, 1310 nm, 40 km, G.652 fiber
- L-1.2, 1550 nm, 80 km, G.652/G.654 fiber
- L-1.3, 1550 nm, 80 km, G.653 fiber
- V-1.2, 1550 nm, 120 km, G.652 fiber
 STM-1 electrical SFP options:
- DIN 1.0/2.3 75 Ohm, 100 m, coaxial pair cable

40
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8xSTM-1e (WP)
 WP: With Protection function.
: The system supports STM-1e card which has 1:N(N<=4) equipment protection.
: The card provide 8 ports, and it must be installed accompanied by the 8xSTM-1e
IO card.

: SNCP/I,SNCP/N;MSP;EOW and DCC (including OSI-light, GRE tunnel, third-party


DCC transparency, etc.) should be supported by this card.

 Note:
: (1)not supporting MSP protection and EPG protection simultaneously
: (2)supporting SNCP and EPG simultaneously
: (3)EOW/DCC+EPG
: (4)timing switching together with STM-1e EPG

41
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8xSTM-1e I/O
 The card provides 8xSTM-1e interfaces at 75Ohm impedance with
CC4 Connectors. It also support the 1:N protection function against
the equipment failure on 8xSTM-1e function card.

42
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
12xE3/DS3 (WP)
 WP: With Protection function.
: The card provides 12 ports, and it must be installed
accompanied by the 12xE3/DS3 IO card.
: Each port is configurable to either E3 mode or DS3 mode
independently.

43
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
12xE3/DS3 I/O
 The card provides 12 E3/DS3 interfaces at 75Ohm impedance. It
also support the 1:N protection function against the equipment
failure on 12xE3/DS3(WP) function card.

 The connectors are Stacked CC4 Connectors

44
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
126xE1/R (WP)
 WP: With Protection function.
: (1)The system supports 126xE1 card that has 1:N (N<=4) equipment
protection.
: (2)The card supports retiming function.
: (3)The card provides 126 ports, and it must be installed accompanied by
the corresponding IO card (each IO card can provide 63 interface, so one
126xE1 function card needs two IO cards)

 Following configuration via software should be supported:


: (1)Each port should support retiming function, retiming function can be
enabled or disabled based on per port.
: (2)As to port’s encode/decode mode: for E1 mode, it is fixed to HDB3
: (3)Each port supports inward and outward loopback.
: (4)Every E1 ports can be used as candidate timing reference source, but
maximum only four ports can be selected at the same time.

45
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
63xE1 I/O
 The card provides 63 E1 interfaces, the impedance of 75 Ohm and
120 Ohm can be configured by operator. It also support the 1:N
protection function against the equipment failure on 126xE1(WP)
card.
 The connector is based 2mm connector

46
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
1x10GE/T
 Key functions of this card are summarized as follows:
 GFP encapsulation (ITU-T G.7041/Y.1303)
 LCAS supported
 VC-4-Xv mapping
 SDH and Ethernet performance monitoring and alarms
 This module provides one 10Gigabit Ethernet optical interfaces
(XFP). It only supports transparent transmission function. The port
is transparently mapped to a VC-4-Xv via GFP, and LCAS supported.
 The physical card bandwidth connected to backplane is 10G.
 Each 10 GE optical XFP interface can be equipped with the following XFP modules:
 10GBASE-SR/SW Ethernet (850 nm, 300 m, multiple mode fiber)
 10GBASE-LR/LW (I-64.1, 1310 nm, 2 km, G.652 fiber)
 10GBASE-ER/EW (S-64.2b, 1550 nm, 40 km, G.652 fiber)
 10GBASE-ZR/ZL (L-64.2c, 1550 nm, 80 km, G.652 fiber)

47
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Ethernet ptp connections
1 x 10GbE Transparent Card - Block Diagram

4x2.5G LVDS
1x For Working

10GbE Base CC (W)


client signals
SerDes Circuits
EoS
10GE 4x2.5G LVDS
Ethernet GFP-F For Protection
XFP Tranceiver
Controller xVCGs CC (P)

Backplane

Client
Network
(LAN) transparent (WAN)
VCG

LAN

48
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
8xGE/T
 Key functions of this card are summarized as follows:
 Auto negotiation, flow control, IEEE 802.3, and Ethernet II frame
structure supported by the GE ports
 GFP encapsulation (ITU-T G.7041/Y.1303)
 LCAS supported on all layers, VC-4, VC-3, VC-12
 VC-4-Xv, VC-3-Xv, and VC-12-Xv mapping
 SDH and Ethernet performance monitoring and alarms

 Supported SFP modules:


 GE optical SFP options (in accordance to IEEE 802.3):
- 1 G FC/GE Multirate SFP (1000 Base-Sx, 850 nm, 500 m, 50 um MMF)
- 1 G FC/GE Multirate SFP (1000 Base-Lx, 1310 nm, 10 km, G.652 Single Mode Fiber (SMF))
- 1 G FC/GE Multirate SFP (1000 Base, 1310 nm, 40 km, G.652 SMF)
- 1 G FC/GE Multirate SFP (1000 Base-Zx, 1550 nm, 80 km, G.652 SMF)
 GE bi-directional electrical SFP option:
- GE-LX Module, Bidi 10km, Tx:1310, Rx:1490
- GE-LX Module, Bidi 10km, Tx:1490, Rx:1310
 GE electrical SFP option (in accordance to IEEE 802.3-2002 and IEEE 802.3ab):

- 1000 Base-T, 100 m, unshielded twisted-pair category-6 cable

49
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
6xGE+4FEGE/A
The 6 x GE + 4 x FEGE/A card provides 10 LAN ports and 36 WAN ports as
follows:

Front panel interface:


 6 GE optical or electrical SFP interfaces
 4 electrical 10/100/1000 Mbps auto negotiation interfaces (RJ 45)

Backplane side:
 12 GE (1000 Mbps) WAN ports
 24 FE (100 Mbps) WAN ports
The 6 x GE + 4 x FEGE/A card supports L2 switching, GFP, higher order virtual
concatenation, LCAS, and LAN/WAN port aggregation. Each GE port supports VC-4
Xv (X = 1 to 7) and VC-3-Xv (X = 1 to 21) bandwidth. Each FE supports VC-3-Xv (X = 1
to 3) and VC-12-Xv (X = 1 to 46) bandwidth.

50
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Ethernet ptmp and mptmp Connections
6 x GbE + 4 FEGE Layer 2 (Aggregation) Card - Block Diagram

#1
SFP
6 x 1000 Base
SX/LX 4x2.5G LVDS
client signals
Aggre- For Working CC (W)

#6 gation/ EoS
SFP
GE Switch GFP-F
4x2.5G LVDS
36xVCG
PHY For
CC (P)
RJ 45 Protection

4 x 10/100/1000
RJ 45
BaseT
client signals Backplane
RJ 45

RJ 45
WAN channels:
Aggregation 12x 1000M WAN
Network
Client WAN
LAN 24x 100M WAN (WAN)
(LAN) Up to 36 VCGs

51
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
6 x GbE + 4 FEGE Layer 2 (Aggregation) Card
- Principle

Virtual Con-
catenation
GFP #1 to VLAN #1 Group 1

GBE 1

SDH (WAN)
GFP #2 to VLAN #2 Virtual Con-
catenation
Group 2
GFP #2 to VLAN #3

GBE x GFP #2 to VLAN #4

Client Network
WAN
(LAN)
LAN (WAN)

Aggregation

52
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
6xGE+4FEGE/A
The main functions supported by this card are as follows:
 LAN/WAN ports aggregation
 Multicast IGMP snooping
 VLAN and double VLAN tagging
 ACL based on MAC addresses
 Per port rate limiting function: The rate range of each port is from 128 Kbps
to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and the rate provisioning
granularity is 128 Kbps.
 Per VLAN rate limiting function: The rate range of each VLAN is from 128 Kbps
to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and the rate provisioning
granularity is 128 Kbps.
 Auto negotiation, flow control, IEEE 802.3, and Ethernet II frame structure
supported by the FE/GE ports
 GFP encapsulation (ITU-T G.7041/Y.1303)
 VC-4-Xv (X = 1...7), VC-3-Xv (X = 1 to 21), and LCAS function supported by the
GE WAN port
 VC-3-Xv (X = 1 to 3) or VC-12-Xv (X = 1 to 46), and LCAS function supported by
the FE WAN port
 SDH and Ethernet performance monitoring and alarms
 GVRP function
 MSTP function

53
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2xGE+12xFE/RPR
The 2 x GE + 12 x FE/RPR card provides 14 LAN ports and 2 RPR WAN ports as follows:

Front panel interface:


 2 GE optical or electrical SFP interfaces
 12 electrical 10/100 Mbps auto negotiation interfaces using 6 RJ 45 ports

Backplane side:
 2 RPR WAN ports with 8 x VC-4 bandwidth each

An extra Ethernet connector converter must be used for the FE RJ 45 interfaces to split them
into two separate FE interfaces and connect customer equipment. Each RJ 45 interface has two
LEDs, one to indicate the send/receive status for each FE interface.

 The 2 x GE + 12 x FEGE/RPR card supports L2 switching, RPR MAC, GFP, and higher order
virtual concatenation.

54
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2 x GbE + 12 FEGE RPR Card - Block Diagram
SFP 8 x VC 4 east
to the backplane
GE
SFP 1xVCG VC-4-mv
PHY
(m=1..8)
EoS
RJ 45
GFP-F
12 x RPR-
RJ 45
10/100 BaseT MAC
client signals
RJ 45 EoS
(6 physical ifs with 100
12 access)
GFP-F
RJ 45 BaseT
PHY 8 x VC 4 west
RJ 45 to the backplane

RJ 45 1xVCG VC-4-mv
(m=1..8)

RPR / L2 switching
Client WAN
Network
LAN
(LAN) (WAN)
Up to 36 VCGs

55
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
2xGE+12xFE/RPR
The main RPR functions supported by this card are as follows:
: Source weighted fairness (class B and class C traffic only)
: 3 service of classes (class A, class B, and class C). Class A traffic can
occupy up to 50% of total RPR bandwidth and only the class A traffic
supports strict order transmission.
: Per port based service rate limiting function: The rate range of each
port is from 128 Kbps to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and
the rate provisioning granularity is 128 Kbps.
: Per VLAN based service rate limiting function: The rate range of each
VLAN is from 128 Kbps to 100 Mbps (FE) or 128 Kbps to 1 Gbps (GE), and
the rate provisioning granularity is 128 Kbps.
: RPR layer protection: steering or wrap protection (user provisional)
: Topology discovery
: Auto negotiation, flow control, IEEE 802.3, and Ethernet II frame
structure supported by the FE/GE ports
: GFP encapsulation (ITU-T G.7041/Y.1303)
: VC-4-Xv, VC-3-Xv, and VC-12-Xv mapping
: SDH and Ethernet performance monitoring and alarms

56
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Guides

57
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Chassis Slots and Backplane Capacity
PWR PWR

H H H H H Equipment Core slots


I I I I S S S S S I I I I I
S HS slots, 20G & LOCC slots
O O O O / / / / / O O O O O
I
1 2 3 4 E E E E E 5 6 7 8 9
1 1 1 1 1 HS slots, 20G backplane w.DS3/STM-1E
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

Fiber Space HS slots, 20G backplane

HS slots, 10G backplane w. E1 STM-1E


H H H H H H H
S H H H H H H H H H S HS slots, 20G backplane w. E1 STM-1E
O O S S S S S
C S S S S S S S S S C
C C / / / / /
IO slots
C C E E E E E
Note: The small italic number indicates slot number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
HS =High speed slot (20G)
Fiber Duct HS/E =HS & also support DS3/STM-1E
Fan Tray HS/E1 =10G High Speed & E1 STM-1E
Fan Tray HOCC =High Order Cross-Connect slot
SC =System Controller slot
Air Filter Tray PWR =Power Supply slot, fixed with chassis
FW4570

58
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Slot and plug-ins guide (Summary)
Interface Card type

STM
STM STM STM E3/
- LO
Ether1 Ether2 - - - D
Slot color Legend Slot Category 4 E1 C OA
*a *b 6 1 1 S
/ C
4 6 E 3
1

HS/LOCC
(Slot 5 – 8)
20G backplane x x x x x x x

HS
(Slot 2/3/4 +Slot11/12)
20G backplane x x x x x x

HS/E
(Slot 13 – 17)
20G backplane x x x x x x x x

HS/E1
(Slot 28)
20G backplane x x x x x x x

HS/E1
(Slot 24 – 27)
10G backplane x *1 *2 x x x x

Common Common

IO 1-9 Connector card

59
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Slot and plug-ins guide (Remarks)

*1: Only the last port of 2xSTM-64

*2: Only the last 4 ports of 8xSTM-16

*a: 1x10GE, 8xGE, 2xGE+12xFE/RPR

*b: 6xGE+4xFEGE/A (Only up to 4 cards in a


subrack)

60
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Service port density (Summary)
Service FW4570

STM-64 34

STM-16 136

STM-4/1o 152

STM-1 E 64 (with 1:4 card protection)

10GE 19

GE 152

FE 228

38 (2 channels in 8xGE/T card can be


1G FC
configured as 1G FC)

E3/DS3 48 (with 1:4 card protection)

E1 504 (with 1:4 card protection)

61
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
LOCC configuration Mounting guide
PWR PWR

H H H H H  There are 4 Slots (5,6,7,8) could


I I I I S S S S S I I I I I
O O O O
S
/ / / / / O O O O O
be used as LOCC slots.
I
1 2 3 4 E E E E E 5 6 7 8 9
1 1 1 1 1  protection group
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
20G LOCC : slot 6(W)/slot 7(P)
Fan Tray
Fiber Space 40G LOCC : slot 5,6(W)/slot 7,8(P)
 Upgrade Rule
L L H H H H H H H
S H H H H H H H S
O O O O S S S S S LOCC from 20G to 40G without
C S S S S S S S C
C C C C / / / / /
C C C C E E E E E traffic interruption
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Air Filer Tray
FW4570

62
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Scenario #1: Typical MADM64 MSPP
PWR PWR
 ADM64:
 8x GE/T 8x 8x 8x 8x 8x
H H H H
S S S S S
 6x GE+ 4FEGE/A I I I I S S S S I
S T T T T T
O O O O / / / / O
I M M M M M
 2x GE+ 12x FE/RPR 1 2 3 4 E E E E 5
|
1 1 1 1
 4x 8x STM-4/1 16 IO IO IO IO
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
 4x 8x STM-1E w. Protection Fiber Space
 4x STM-16 subtending ring 8 8 8 8
6 8x
8 x x x x x 2 2 8x 8x 8x 8x
 2x STM-64 Ring S
x G S S S S H H x x S S S S
S E R T S
G + T T T T O O S S T T T T
C 4 P M C
E M M M M C C T T M M M M
F R |
/ E 4 4 4 4 C C M M | | | |
G 1E
T E
/1 /1 /1 /1 64 64 1E 1E 1E 1E
1 2 3 4 5 6 7 8 9
(p)
10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray

FW4570

63
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Scenario #2: Typical MADM64 MSPP

 ADM64: PWR PWR

 504x E1 1 1 1 1 1 8x
 8x STM-1E with protection 63 63 63 63 2 2 2 2 2 63 63 63 63 S
x x x x S 6 6 6 6 6 x x x x T
 1x 10GE /T E1 E1 E1 E1 I E E E E E E1 E1 E1 E1 M
IO IO IO IO 1 1 1 1 1 IO IO IO IO
 8x GE/T g1 g2 (p) g3 g4 IO
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
 8x STM-4/1
Fiber Space
 2x GE+12x FE/RPR 8
1 8x
 2x STM-16 subtending Rings 8 x 2 2 8x 8x
x S
x S L L H H x x S S
10 R T S
 2x STM-64 Ring G T O O O O S S T T
G P M C
E M C C C C T T M M
E R |
/ 4 C C C C M M | |
/ 1E
T /1 64 64 16 1E
1 2
T3 4 5 6 7 8 9 10 11 12 13 14
(p)
15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray
FW4570

64
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Configuration Scenario #3: Typical ADM64 MSPP

 ADM64: PWR PWR

 1512x E1 1 1 1 1 1 8x
(with 2 extension shelves) 63 63 63 63 2 2 2 2 2 63 63 63 63 S
 8x STM-1E with protection x x x x S 6 6 6 6 6 x x x x T
E1 E1 E1 E1 I E E E E E E1 E1 E1 E1 M
 2xGE + 12xFE /RPR IO IO IO IO 1 1 1 1 1 IO IO IO IO
g1 g2 (p) g3 g4 IO
 4xSTM-4 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

 12xSTM-1 Fiber Space


8 8 8
 2x STM-16 subtending rings 8x
x x x 2 2 8x 8x
S
 1x STM-64 Ring S S L L S H H x x S S
R T S
S T T O O T O O S S T T
P M C
 Slot 2 (8xSTM4/1) is used to C M M C C M C C T T M M
R |
connect with two extension 4 4 C C 4 C C M M | |
1E
/1 /1 /1 64 64 16 1E
shelves(FW4370) 1 2 3 4 5 6 7 8 9 10 11 12 13 14
(p)
15 16 17 18

 Each 2 STM-4 ports connect Fiber Duct


with CC cards (W+P) in one Fan Tray
extension shelf(FW4370) Fan Tray
Air Filter Tray
FW4570

65
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
W
R

SC
P

8
2
W
R
P

XCT2 w. LC
7

XCT 1 w. LC
6

Fan Tray
5

63xE1 (P)
4

63xE1 #4 (W)
Configuration Scenario #3: Typical ADM64 MSPP

FW4370

63xE1 #3 (W)
3

63xE1 #2 (W)
2

63xE1 #1 (W)
1
20

63 x E1 I/O #4
19

63 x E1 I/O #3

Fujitsu and Fujitsu Customer Use Only


63 x E1 I/O #2
18

63 x E1 I/O #1
17
 504x E1(with 2 extension shelves)

W
R

SC
P

8
2
 2xFW4370 (as extension shelf)

W
R
P

XCT2 w. LC

7
XCT 1 w. LC

Fan Tray
5
63xE1 (P)

4
63xE1 #4 (W)
63xE1 #3 (W)

FW4370
63xE1 #2 (W)

2
63xE1 #1 (W)

1
20
63 x E1 I/O #4

19
63 x E1 I/O #3

SDH/FW4570/022-02
63 x E1 I/O #2

18
63 x E1 I/O #1

17

66
Configuration Scenario #4:
PWR PWR

 4xS64.1 8 8 8 8
2
x x x x
x
 16xS16.1 I I I I S S S S I I I I I
S S
O O O O T T T T O O O O O
 12xS4.1 I T
1 2 3 4 M M M M 5 6 7 8 9
M
4 4 4 4
 24xS1.1 64
/1
19 20 21 22 23 24
/1
25
/1
27
/1
27 28 29 30 31 32 33
 4x1000BaseTx Fiber Space
8
8 2 8x 8x
x
x H H x S S
S S
S G O O S T T
T C
C E C C T M M
M
/ C C M | |
4
T 64 16 16
1 2 3 4
/1
5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray

FW4570

67
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Synchronization
The system interface panel of FW4570 interfaces:
 External clock source (T3): 2 input port, framed 2048kbit/s or
unframed 2048 kHz (75/120 Ohm)
 Synchronize output (T4): 2 output port, framed 2048kbit/s or
unframed 2048 kHz (75W/120W)

Selection of the following 4 timing references:


 Line/tributary timing (STM-1/-4/-16/-64 lines, or E1 tributary)
 External station clock input timing
 Internal clock (ITU-T G.813 option 1)
 E1 tributary timing (any E1 port can be selected as the timing
source)

Note:
The maximum number of total selected timing source per NE is 8. Any port of PDH or SDH
card can be used as candidate timing reference, but for each card, maximum 4 ports can
be selected.

68
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Protection Mechanism

69
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
FW4570 Protection Overview
• Protection Architectures (How they work):
• 1+1
• 1:1
• 1:N
• Protection Types (How they are applied):
• Equipment/Card protection
• Traffic protection
• Path protection (SNCP)
• Section protection (1+1 & 1:N MSP, MS-SPRing)
• DNI/ DRI
• Packet protection (via RPR)

70
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Network Protection
 SDH Layer Protection
 STM-64: 2F/4F MS-SPRING, MSP 1+1, SNCP/NI HO/LO
 STM-16: 2F/4F MS-SPRING, MSP 1+1, SNCP/NI HO/LO
 STM-4: 2F MS-SPRING, MSP 1+1, SNCP/NI HO/LO
 STM-1: MSP 1+1, SNCP/NI HO/LO
 STM-1E: MSP 1+1(MSP and EPG can not be configured
simultaneously), Hardware 1:4 protection, SNCP/NI HO/LO
 Support 1:N bidirectional revertive MSP (unidirectional 1:N MSP is
not supported)
 Ethernet Layer Protection
 GFP (Generic Framing Procedure) and LCAS (Link Capacity
Adjustment Scheme)
 RSTP/MSTP (Rapid/Multi Spanning Tree Protocol) per VLAN, or per
VLAN group
 RPR steering protection based on 802.17 MAC

71
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Equipment Protection
 HOCC-High Order Cross-Connect Card
 1+1 protection with timing protection together

 LOCC-Low Order Cross-Connect Card


 1+1 protection

 PWR-Power Supply Card


 1+1 protection

 STM-1E Card
 1:4 protection

 E3/DS3 Card
 1:4 protection

 E1 Card
 1:4 protection

72
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SNCP – Normal operation
Example (only one direction is shown):

PWR IO SNCP types (SNCP N/I):


VC-4-Xc (X = 1, 4, 16, 64), VC-3, and VC-12 levels
H H H H H
I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 E E E E E 5 6 7 8 9
1 1 1 1 1

19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
4
Fiber Space Tail end select

PWR IO

S H H H H H H H
H
O
H
O
H H
H H
S S
H
S
H
S
H
S
S SDH cloud
C S S S S S S S S S C
C C / / / / / H H H H H
C C E E E E E I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1 Pat 1 2 3 4 E E E E E 5 6 7 8 9
1 2 3 4 5 6 7 8
Fiber Duct hA 1 1 1 1 1

Fan Tray 19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
Fan Tray 4
Fiber Space
Pat
Air Filter Tray
h B
Head-end
broadcast S H H H H H H H
H H
H H
H H H H H
S
O O S S S S S
C S S S S S S S S S C
C C / / / / /
C C E E E E E

1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1
1 2 3 4 5 6 7 8
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray

73
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
SNCP – Failure event
Example (only one direction is shown):

PWR IO Unidirectional switch

H H H H H
I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 E E E E E 5 6 7 8 9
1 1 1 1 1

19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
4
Fiber Space Tail end select

PWR IO

S H H H H H H H
H
O
H
O
H H
H H
S S
H
S
H
S
H
S
S SDH cloud
C S S S S S S S S S C
C C / / / / / H H H H H
C C E E E E E I I I I S S S S S I I I I I
S
O O O O / / / / / O O O O O
I
1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1 Pat 1 2 3 4 E E E E E 5 6 7 8 9
1 2 3 4 5 6 7 8
Fiber Duct hA 1 1 1 1 1

Fan Tray 19 20 21 22 23 2 25 26 27 28 29 30 31 32 33
Fan Tray 4
Fiber Space
Pat
Air Filter Tray
h B
Head-end
broadcast S H H H H H H H
H H
H H
H H H H H
S
O O S S S S S
C S S S S S S S S S C
C C / / / / /
C C E E E E E

1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1
1 2 3 4 5 6 7 8
Fiber Duct
Fan Tray
Fan Tray
Air Filter Tray

74
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
1+1 MSP (for all STM-N)

 MSP 1+1 can be formed from any two STM-N ports regardless of
whether it's on the same card, different cards, or non-adjacent slots
(fully flexible)
 Non-Revertive/ Revertive mode supported & Uni/ Bi switching can be
configured
Example: Working port

Protection port

1+1 MSP 1+1 MSP

1+1 MSP

75
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
1:N MSP for traffic and port protection

 1:N port protection can be configured for:

 Traffic protection
1:N MSP (N ≤ 14)
1:3 port
protection,
 . Extra traffic can be transmitted on the protection path 1:4 port
protection

Extra traffic will be dropped off when there is switching occur

Working port

Protection port
 Important: Since card protection here is
based on MSP, client equipment must
FW4570
support MSP also! 1:N MSP on both ends!

PDH Protect. Slot


Only Bidirectional switching is supported.

CLU Slot

CLU Slot
PDH Slot

PDH Slot

PDH Slot

PDH Slot
LSU Slot

LSU Slot

LSU Slot

LSU Slot

LSU Slot

LSU Slot

LSU Slot

LSU Slot
201

215
214


203

204

206

207

209

210

211
202

205

208

212

213
Backplane

 Revertive/ Non-revertive

MSP Protection No.1

MSP Protection No.2

MSP Protection No.3

MSP Protection No.4

MSP Protection No.5


MSP Worker No.5
MSP Worker No.2
MSP Worker No.1

MSP Worker No.3

MSP Worker No.4


Client

311

312

313
301

302

303

308

309

310
304

305

306

307

314
76
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Mixed protection schemes

 It is possible to implement multiple protection schemes on a card (in conjunction with


other cards)

Example:

Working port
MS-SPRING: Up to 16 nodes
Protection port

wes
t 1+1 MSP,
eas
t 2-F MS-SPRing and
4-F MS-SPRing
at the same time
2-F MS-SPRing

we we ea east
st st st

4-F MS-SPRing

77
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
E1 Card 1:4 Protection
PWR PWR
 Provide up to 1 group 1:4 E1 card
protection in FW4570 system, 1 1 1 1 1
63 63 63 63 63 63 63 63
shown on the right figure 2 2 2 2 2
E1 E1 E1 E1 E1 E1 E1 E1 I
S 6 6 6 6 6
IO IO IO IO IO IO IO IO O
 Protection Pair: I E E E E E
9
1 1 1 1 1
g1 g1 g2 g2 g3 g3 g4 g4
 Slot 26 is the dedicated protected g1 g2 (p) g3 g4
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
slot, universal function card for
Fiber Space
both working and protection..

 Process IO Pairs
H H H H H H H
S H H H H H H H H H S
 Slot 19 (63 E1 IO), Slot 20 (63 E1 IO) C S S S S S S S
O O
S S
S S S S S
C
-- Slot 24 (126 E1) C C / / / / /
C C E E E E E
 Slot 21 (63 E1 IO), Slot 22 (63 E1 IO)
-- Slot 25 (126 E1) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
 Slot 29 (63 E1 IO), Slot 30 (63 E1 IO) Fan Tray
-- Slot 27 (126 E1) Fan Tray
 Slot 31 (63 E1 IO), Slot 32 (63 E1 IO) Air Filter Tray
-- Slot 28 (126 E1) FW4570

78
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
E3/DS3 Card 1:4 Protection
PWR PWR
 Provide up to 1 group 1:4 12x
E3/DS3 card protection in FW4570 E3 E3 E3 E3
H H H H H
system, shown on the right figure / / / /
I I I I S S S S S I
S DS DS DS DS
O O O O / / / / / O
I 3 3 3 3
 Protection Pair: 1 2 3 4 E E E E E 5
IO IO IO IO
1 1 1 1 1
 Slot 15 is the dedicated protected g1 g2 g3 g4
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
slot, universal function card for
Fiber Space
both working and protection.
E3 E3 E3 E3 E3
 Process IO Pairs
H H / / / / /
S H H H H H H H H H S
 Slot 30 (12 E3/DS3 IO) -- Slot 13 C S S S S S S S
O O
S S
DSDSDSDSDS
C
(12 E3/DS3) C C 3 3 3 3 3
C C
 - Slot 31 (12 E3/DS3 IO) -- Slot 14 g1 g2 (p) g3 g4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
(12 E3/DS3)
Fiber Duct
 - Slot 32 (12 E3/DS3 IO) -- Slot 16 FanFanTrayTray
(12 E3/DS3) Fan Tray
 - Slot 33 (12 E3/DS3 IO) -- Slot 17 Air Filter Tray
(12 E3/DS3) FW4570

79
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
STM-1E Card 1:4 Protection
 Provide up to 2 groups 1:4 8xSTM-1 el. card
PWR PWR
protection in FW4570 system, shown on the
right figure
S S S S S S S S S S S S S
 Protection Pair for group 1: T T T T T T T T T T T T T
I
 Slot 17 is the dedicated protected slot for M M M M S M M M M M M M M M
O
STM-1E, universal function card for both 1 1 1 1 I | | | | | 1 1 1 1
5
working and protection. IO IO IO IO 1E 1E 1E 1E 1E IO IO IO IO
 Process IO Pairs G1 G2 G3 G4 G1G2G3G4 (p) g1 g2 g3 g4
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
 Slot 30 (8 STM-1E IO) -- Slot 13 (8 STM-1E)
Fiber Space
 - Slot 31 (8 STM-1E IO) -- Slot 14 (8 STM-1E)
 - Slot 32 (8 STM-1E IO) -- Slot 15 (8 STM-1E) S S S S S
 - Slot 33 (8 STM-1E IO) -- Slot 16 (8 STM-1E) H H T T T T T
S H H H H H H H H H S
 Protection Pair for group 2:
O O M M M M M
C S S S S S S S S S C
C C | | | | |
 Slot 28 is the dedicated protected slot for
C C 1E 1E 1E 1E 1E
STM-1E, universal function card for both
g1 g2 g3 g4 (p)
working and protection.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
 Process IO Pairs Fiber Duct
 Slot 19 (8 STM-1E IO) -- Slot 24 (8 STM-1E) FAN Tray
 - Slot 20 (8 STM-1E IO) -- Slot 25 (8 STM-1E) FAN Tray
 - Slot 21 (8 STM-1E IO) -- Slot 26 (8 STM-1E) Air Filter Tray
 - Slot 22 (8 STM-1E IO) -- Slot 27 (8 STM-1E)
FW4570

80
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Mixed Protection 1
PWR PWR
 FW4570 can support 4 protection S
S
S 1 1 1 S E3 T
groups simultaneously. T 63 63 63 63
T 2 2 2 T / M
M E1 E1 E1 E1
S M 6 6 6 M DS 1
1 IO IO IO IO
 252 E1 (1:2 P) I | E E E | 3 E
E
1E 1 1 1 1E IO IO
 8 STM-1E (1:1 P) IO g2 g2 g3 g3
G1 g2 (p) g3 (p) g2 g4
G1
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
 8 STM-1E (1:1 P)
Fiber Space
 12 E3 (1:1 P)
E3 E3 S S
L L
H H / / T T
S H H H H O O H H H S
O O DSDS M M
C S S S S C C S S S C
C C 3 3 | |
C C
C C 1E 1E
g2 (p) g4 (p)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filer Tray
FW4570

81
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Mixed Protection 2
PWR PWR
 FW4570 can support 4 protection S
S 1 1 1 S E3 E3 E3
groups simultaneously. T 63 63
T 2 2 2 T
63 63
/ / /
M E1 E1 E1 E1
S M 6 6 6 M DS DS DS
1 IO IO IO IO
 252 E1 (1:2 P) I | E E E | 3 3 3
E
1E 1 1 1 1E IO IO IO
 8 STM-1E (1:1 P) IO g2 g2 g3 g3
G1 g2 (p) g3 (p) g2 g3 g4
G1
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
 36 E3 (1:3 P)
Fiber Space

E3E3 E3 E3
L L
H H H / / / /
S H H H H O O H H H S
O O S DSDSDSDS
C S S S S C C S S S C
C C / 3 3 3 3
C C
C C E
g2 (p) g3 g4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Fiber Duct
Fan Tray
Fan Tray
Air Filer Tray

FW4570

82
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Basic Operation and Maintenance

83
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Operating & Maintenance Features:

LCT Operation Administration task Maintenance task Troubleshooting

External Interfaces Operating tasks

NMS Operation
Few categories as described above:

84
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Maintenance task
Features for Maintenance task: Features for Operating task:

Loopback Performance management


AIS Injection Cross connect configuration and management
PRBS TP configuration and management
LED test Protection management
Active alarms Ethernet management
History alarms
Performance monitoring
Software backup/ download
Alarm Inhibit
Alarm severity
Alarm persistent time
Alarm Out
Audible alarm

85
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Loopback
Traffic will be interrupted when loopback is active

Towards equipment side (cross connect side)

Outer loop Inner loop

Interface port
FW4570

Towards outer side from physical port

The loopback feature is available for all SDH and PDH port + Optical interface of GE

86
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Laser Safety shutdown
• ALS compliant to ITU-T G.783 ITU G.664
• ALS features: Enabled/ Disabled Avoid direct eye contact
• Supported for all SDH interface port (STM-1/4/16/64) to laser output
(Class 1 laser warning)

ALS shall be set to Enabled mode for ALS feature to work


Software command: No command/ Manual Restart/ Manual Test

Power level When there is Loss, ALS is activated: Laser is shutdown


Short pulse of optical power
Normal operation
Manual restart/ Test

Time

60 ~ 90 seconds interval 60 ~ 90 seconds interval

87
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
LED test/ ACO/ SUP

LED color:
1 PWR (green)
1 FAULT (red) Alarm Cut Off:
Alarm Suppress:
1 CR (red) After Press ACO, office alarms
Visible alarms is not reported
1 MJ (orange) (Audible) will be cut
1 MN (yellow)

Pressing LED button: All cards equipped in shelf


shall FLASHING for a few seconds before going to
normal state

88
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
PRBS Feature
PRBS (pseudo-random binary sequence) is used to measure the bit-error performance of digital
systems by directly comparing a received pseudo-random test pattern with a locally generated
test pattern identical to the transmitted test pattern

Recommendations
Bit Recommendations
corresponding to Bit rate Test
rates corresponding to
digital line section/line tolerance Pattern PRBS is supported for
(kbps) multiplex system
system E1/E3
215 – 1,
1544 G.733 G.911, G.951, G.955 ± 50 · 10–6
220 – 1

2048 G.732 G.921, G.952, G.956 ± 50 · 10–6 215 – 1

34368 G.751 G.921, G.954, G.956 ± 20 · 10–6 223 – 1

44736 G.752 G.914, G.953, G.955 ± 20 · 10–6 215 – 1,

220 – 1

139264 G.751 G.921, G.954, G.956 ± 15 · 10–6 223 – 1

Note:
Activating PRBS test can cause service interruption

89
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Overall Fault Management Feature/ Mechanism
Understanding overall system features

Fault Management

Default: All alarms are inhibit


(alarms are monitored but not reported) Office alarms
Events/ Log PM
Types: MDO/MDI
Critical/Major/ Minor/Warning
Enable Viewing Alarms By LED indication Alarm persistent
Alarm monitor Active & History Time

By software:
LCT/ NMS Detection time Clearance time
(Def: 2s) (Def: 10s)
For all common alarms 0: Immediately report/ clear
(Alarms is not inhibited)
Enable alarms type
- RS-LOF/ TU-LOM/ TU-LOP/ AIS/ RDI/ TIM/ SLM

Refer to product manual for details:


I.E Alarms/ Performance Monitoring/ Etc

90
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Performance Monitoring
Current and previous values: 15 minute period and 24 hour period
Historical values: maximum 16 records for 15 minute periods, 1 record for 24 hour period

PM Monitoring options:
Performance Monitoring
Enabled/ Disabled per
card/ port base

SDH/PDH Ethernet

Functions:
•PM (processing and reporting) of parameters.
•Inquiry of current and historical values of the parameters.
•Supervision of parameter thresholds (Not for Ethernet)

91
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only
Performance Monitoring Parameter
 Depending on the supported protocols of the transponder, the following performance monitoring
parameters are supported:
 SDH: supports the following regenerator section and multiplex section performance parameters, counted
according to G.829:
 Background Block Error (BBE)
 Consecutive Severely Errored Second (CSES)
 Errored Second (ES)
 Out of Frame Second (OFS)
 Point Justification Count Negative (PJCN)
 Point Justification Count Positive (PJCP)
 Severely Errored Second (SES)
 Unavailable Second (UAS)
 No far-end PM parameters are defined for the SDH Regenerator Section.
 Ethernet performance monitoring supports the following parameters:
 Received Total Byte
 Received Total/Good/Bad/Unicast/Multicast/Broadcast/Fragment Packet
 Received Dropped/Undersize/Oversize Good Packet
 Receive Good Pause Packet

92
SDH/FW4570/022-02 Fujitsu and Fujitsu Customer Use Only