Você está na página 1de 8

Application examples for RVP

May, 2014
Table of contents

1. Dräger RVP 2400


2. Dräger RVP 3900
3. Dräger RVP 5000 / Dräger Vision32

2 | 33 Application examples for RVP | Helge Olsson | May 27, 2014


Table of contents

1. Dräger RVP 2400


2. Dräger RVP 3900
3. Dräger RVP 5000 / Dräger Vision32

3 | 33 Application examples for RVP | Helge Olsson | May 27, 2014


Application examples for RVP
Dräger Regard 2400 / 2410

Internal communication terminals on


Regard 2400 and 2410

Connection terminals of Regard 2400 Connection terminals of Regard 2410


18 35

+ S - + S - + S - + S - + D1 - + D2 -
Channel A Channel B Channel C Channel D Digital Digital
Input Input

Power Supply

Connection
RS 485

Alarm 1

Alarm 2
24V DC

Horn
Error
RS485 Interface only + - A B COM

for optional modules


1 17

RS485 Interface only


for optional modules

4 | 33 Application examples for RVP | Helge Olsson | May 27, 2014


Application examples for RVP
Dräger Regard 2400 / 2410

RS 485 External converter module RS485


4

A
B
Com
 The external converter module
PWR
RS485 is required to connect a
Dräger REGARD 2410 to a
RS232
Dräger RVP 2400 visualization
panel.
+24 V
Erde

 The connection port at the REGARD


0V

1
2410 is the RS232 interface on the
front plate.
Power
 The module is for DIN-Rail mounting
 It is NOT POSSIBLE to connect the
module to a REGARD 2400.

5 | 33 Application examples for RVP | Helge Olsson | May 27, 2014


Application examples for RVP
Dräger Regard 2400 / 2410

Internal converter module RS485:

 The internal converter module


RS485 is required to connect a
Dräger REGARD 2400 to a
Dräger RVP 2400 visualization
panel.

 The connection port at the


REGARD 2400 is the RS232
interface on the front plate.

 Installation inside of the REGARD


2400 unit.

6 | 33 Application examples for RVP | Helge Olsson | May 27, 2014


Application examples for RVP
Dräger RVP 2400

RS485 max 1200m

1 2

5 4 3

RS232/RS485 converter (SC00041)

7 | 33 Application examples for RVP | Helge Olsson | May 27, 2014


Application examples for RVP
Dräger RVP 2400

Connection of a Remote - Display

RVP 2400 Server RVP 2400 Remote

RS485
Slave Device 1 Master
RS485 RS485
24xx Slave Master
Slave Device 2
24xx Option
Slave Device 3 Card
24xx RS232/485
Slave Device 4
24xx
Slave Device 5
24xx

8 | 33 Application examples for RVP | Helge Olsson | May 27, 2014