Certificate Number: 17-HS1686631-PDA

29/JAN/2018

Confirmation of Product Type Approval


Please refer to the "Service Restrictions" shown below to determine if Unit Certification is required for this product.
This certificate reflects the information on the product in the ABS Records as of the date and time the certificate is
printed.
Pursuant to the Rules of the American Bureau of Shipping (ABS), the manufacturer of the below listed product held
a valid Manufacturing Assessment (MA) with expiration date of 04-DEC-2022. The continued validity of the
Manufacturing Assessment is dependent on completion of satisfactory audits as required by the ABS Rules.
And; a Product Design Assessment (PDA) valid until subject to continued compliance with the Rules or standards
used in the evaluation of the product.
The above entitle the product to be called Product Type Approved.
The Product Design Assessment is valid for products intended for use on ABS classed vessels, MODUs or facilities
which are in existence or under contract for construction on the date of the ABS Rules used to evaluate the
Product.
ABS makes no representations regarding Type Approval of the Product for use on vessels, MODUs or facilities
built after the date of the ABS Rules used for this evaluation.
Due to wide variety of specifications used in the products ABS has evaluated for Type Approval, it is part of our
contract that; whether the standard is an ABS Rule or a non-ABS Rule, the Client has full responsibility for
continued compliance with the standard.

Product Name: Fire Stop System


Model Name(s): STI Marine Firestop Sealant
Presented to:
STI MARINE, A DIVISION OF SPECIFIED TECHNOLOGIES I
210 EVANS WAY
NJ 08876
United States

Intended Service: Marine & Offshore Applications: 1) Pipe Penetrations in A0 - A60 and H0 - H60
Deck and A0 - A60 and H0 - H120 Bulkhead (steel). 2) Single or Multiple Cable
penetration in A-0, A-60 deck and bulkhead (steel). 3) Bundle Cable penetrations
in A-0, A-60 deck and bulkhead (steel). 4) Pipe and bundle Cable penetration in
A-0, A-60 deck and A-0, A-60 bulkhead (steel). 5) Single armored cable
penetration in A-0, A-60 deck (steel).
Description: Pipe, bundle Cable, or mixture of bundle Cable and Pipe penetrating through fire
rated divisions (Steel). For Pipe penetration: 1a) Steel sleeve: Max 152 mm OD,
152 mm long for pipes, 7 mm wall thickness. 1b) Steel pipe, iron pipe, or rigid steel
conduit: Max 102 mm diameter size. 1c) Sealant installed to a depth of 13 mm and
flush with ends of sleeve. 1d) Min 50 mm thick insulation wrapped around steel
conduit and around pipe for a distance of 305 mm above the deck and 457 mm
beyond the bulkhead on insulated side and secured in place with steel tie wire. Use
128 kg/m3 for H-Class Insulation and 96 kg/m3 for A-Class Insulation. For Single
or Multiple Cable penetration: 2a) 169 mm dia x 150 mm deep x 8 mm thick steel
sleeve welded to the deck or bulkhead. 2b) Single cable or five of multiple cable
insulated with 400 mm length of 25 mm thick 96 kg/m3 insulation. 2c) Sleeve tightly
packed with 96 kg/m3 insulation, recessed from both sides for sealant. 2d) Marine
Firestop Sealant applied to 13 mm thickness, flush with both ends of the sleeve.
2e) 300 mm by 300 mm 75 mm thick 96 kg/m3 insulation installed over steel sleeve
and pin welded to the unexposed side of deck or bulkhead. 2f) One layer of 300

01/29/2018 7:24:36 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 1 of 4
Certificate Number: 17-HS1686631-PDA

mm by 300 mm with 100 mm thick 96kg/m3 insulation under sleeve and pin welded
to the exposed side of deck. For Single or Bundle Cable penetration: 3a) 222 x 521
x 152 mm deep x 8 mm thick with a 111 mm radius steel sleeve welded to the deck
or bulkhead. Sleeve centered in opening. 3b) Single cable insulated with 450 mm
length of 25 mm thick 96 kg/m3 insulation. 3c) 50mm diam. cable bundle insulated
with 450 mm length of 25mm thick 96 kg/m3 insulation. 3d) Sleeve tightly packed
with 96kg/m3 insulation, recessed from both sides for sealant. 3e) Marine Firestop
Sealant applied to 13 mm thickness, flush with both ends of the sleeve. 3f) 370 mm
by 670 mm 75 mm thick 96kg/m3 insulation over steel sleeve and pin welded to the
unexposed side. 3g) For deck, one layer of 370 mm by 670 mm with 100 mm thick
96kg/m3 insulation under sleeve and pin welded to the exposed side. For Bundle
Cable and Pipe penetration: 4a) Same arrangements as Single or Bundle Cable
penetration except item 4b through 4f. 4b) 29 mm (1" Trade Size) copper tube (1.3
mm thick) insulated with 610 mm length of 2 layers of 25mm thick 128 kg/m3
insulation. Insulation extending 137 mm into sleeve. 4c) 50 mm diam. cable bundle
insulated with 500 mm length of 1 layers of 25mm thick 128 kg/m3 insulation.
Insulation extending 137 mm into sleeve. 4d) 60 mm (2" Trade Size) rigid metallic
conduit (3.7 mm thick) insulated with 400 mm long section of 40 mm thick 96kg/m3
insulation installed flush with section of mineral wool on unexposed side. 4e)
169mm (6" Trade Size) Sch 40 steel pipe (6.8 mm thick) insulated with 400 mm
long section of 40 mm thick 96 kg/m3 insulation flush with section of mineral wool
on unexposed side. 4f) For deck, two additional layers of 370mm wide by 670 long
section of 50mm thick 96kg/m3 insulation under sleeve and pin welded to the
exposed side of deck. For Single armored cable penetration in A-0, A-60 deck: 5a)
102mm OD armored cable centered in opening. See attached drawings for further
detailed arrangements.
Tier: 3
Ratings: 1) For Pipe penetration: A0, A15, A30, A60, H0, H15, H30, H60 Decks and A0,
A15, A30, A60, H0, H15, H30, H60, H90, H120 Bulkheads. Watertightness up to 6
bar and Gastightness up to 1 bar. Item 2, 3, 4, and 5 are not rated for watertight or
gas tight penetrations. 2) For Single and Multiple Cable penetration: A0, A60 Deck
and Bulkhead. 3) For bundle Cable penetration: A0, A60 Deck and Bulkhead. 4)
For bundle Cable and Pipe penetration: A0, A60 Deck and A0, A60 Bulkhead. 5)
For Single armored cable penetration: A-0, A-60 Deck.
Service Restrictions: Unit Certification is not required for this product. If the manufacturer or purchaser's
requests an ABS Certificate for compliance with a specification or standard, the
specification or standard, including inspection standards and tolerances, must be
clearly defined. Item (1) The approval for steel pipe penetrations passing through
watertight bulkhead is not to be construed as a substitute for flag Administration's
approval for the purpose of SOLAS (Consolidated Edition 2014), as amended. Item
(1) When requested to be used in watertight bulkheads on passenger ships or
special purpose ships, the penetration system has to comply with the requirements
given in SOLAS (Consolidated Edition 2014), as amended, Ch. II- Reg. 13.2.3.
This approval of penetrations passing through watertight bulkhead is not to be
constructed as a substitute for flag Administration’s approval for the purpose of
SOLAS (Consolidated Edition 2014), as amended. Item (1) H-class insulation
material must be minimum 128 kg/sq. meter density ceramic wool, or H-60
approved type and installed in accordance with the manufacturer's ABS approved
installation drawings to the satisfaction of the Surveyors. Items (1, 2, 3, 4, 5)
A-class insulation material must be minimum 96 kg/sq. meter density ceramic wool,
or A-60 approved type and installed in accordance with the manufacturer's ABS
approved installation drawings to the satisfaction of the Surveyors. The deck and
bulkhead is to be covered by approved A-60 insulation for A-class penetration. For
A-0 deck penetrations (item 2, 3, 4), 100mm thick 96kg/m3 mineral wool pipe
insulation installed under the deck sleeve itself and beside 200 mm around the
sleeve flush with the bottom edge of the sleeve. No more than tested inside
cross-sectional area should be occupied by the cables and/or pipes. The tested
results obtained from a given configuration are generally valid for the tested cables
of sizes equal or small than those tested in accordance with IMO Res.
MSC.307(88) Annex I:Part 3 Appendix A.IV.2.2.6.1. A reduction factor (0.85) in
accordance with 4-8-2/7.7.1(c) of the 2015 Steel Vessels Rules is to be applied to
the current carrying capacity of the cables regardless of the size and number of
bunched cables since temperature rise report is not submitted. Not to be used in
tank boundaries.

01/29/2018 7:24:36 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 2 of 4
Certificate Number: 17-HS1686631-PDA

Comments: The Manufacturer has provided a declaration about the control of, or the lack of
Asbestos in this product. Approval not performed on behalf of any flag
Administration. The scope of Type Approval is to comply with MSC.1/Circ.1221
dated 11 December 2006. Production items are to be manufactured in accordance
with a quality control system which shall be maintained to ensure that items are of
the same standard as per tested/approved prototype. Installation is to be in
accordance with manufacturer's instructions. Please see attached sketch and
descriptions.
Notes / Documentation: This Product Design Assessment (PDA) is valid only for products intended for use
on ABS classed vessels, MODUs or facilities which are in existence or under
contract for construction on the date of the ABS Rules used to evaluate the
Product. 1) Approval of the piping penetration arrangements and materials based
on Southwest Research Institute, Project Number 01.17457.01.001a Test No. 13
dated 22 June 2012 and Project Number 1.17457.01.001b Test No. 17 dated 22
June 2012. Gastightness and Watertightness test performed in accordance with
the DNV Standards for Certification No.2.9, TAP 8-471.19-1. 2) Approval of the
bundle cable, and bundle cable and pipe penetration arrangements and materials
based on the UL Testing fire R14579, Project No 4786112337, System
No.C-DM-8002 (Page T1-30 of 70-Fig.29, Page T1-18 of 70-Fig.17) 3) Approval of
the single, multiple cable, or bundle cable and pipe penetration arrangements and
materials based on the UL Testing File No R14579, Project No 4786319568 (Page
T1-12 of 67-Fig.11, Page T1-37 of 67-Fig.36,Page T1-22 of 67-Fig.20, Page T1-34
of 69-Fig.33) 4) Approval of the single armored cable penetration arrangements
and materials based on the UL Testing File No R14579, Project No 4786873747.
(Page TR1-22 of 59-Fig.21) 5) Tests performed in accordance with the 2010 IMO
FTP Code. System#:MP0115 (Manufacture providing general arrangements
drawing)
Term of Validity: This Product Design Assessment (PDA) Certificate 17-HS1686631-PDA, dated
05/Dec/2017 remains valid until 04/Dec/2022 or until the Rules or specifications
used in the assessment are revised (whichever occurs first). This PDA is intended
for a product to be installed on an ABS classed vessel, MODU or facility which is in
existence or under contract for construction on the date of the ABS Rules or
specifications used to evaluate the Product. Use of the Product on an ABS classed
vessel, MODU or facility which is contracted after the validity date of the ABS Rules
and specifications used to evaluate the Product, will require re-evaluation of the
PDA. Use of the Product for non ABS classed vessels, MODUs or facilities is to be
to an agreement between the manufacturer and intended client.
ABS Rules: 2017 Rules for Condition of Classification, Part 1, 1-1-4/7.7, 1-1-A3 & 1-1-A4 (2017
Rules for Building and Classing Steel Vessel), which covers the following: 2017
Rules for Building and Classing Steel Vessel, 4-8-4/21.13 2017 Rules for Condition
of Classification-Offshore units and Structure, Part 1,1-1-4/9.7, 1-1-A2 & 1-1-A3,
which covers the following: 2017 Rules for Building and Classing Mobile Offshore
Drilling Units, 4-3-3/5.13 & 5-1-1/3.19 (I)
National Standards:
International Standards: Item 1: FTP Code, Annex 1, Part 3, IMO Resolution A.754 (18), (adopted on 4 Nov
1993). The test deviated from the standard by the furnace exposure conditions and
test duration, The test was conducted with the hydrocarbon time-temperature
relationship within the furnace in lieu of the standard time-temperature furnace
environment specified in IMO Resolution A.754 (18) and the test was conducted for
2 hours. Items 2, 3, 4, and 5: 2010 IMO FTP Code, Entered into force on 1 July
2012, Res. MSC.307(88) Annex I : Part 3
Government Authority:
EUMED:
Others: For item 1 Only - Gastightness and Watertightness test performed in accordance
with the DNV Standards for Certification No.2.9, TAP 8-471.19-1.

Model Certificate Model Certificate No Issue Date Expiry Date


PDA 17-HS1686631-PDA 11-DEC-2017 04-DEC-2022

01/29/2018 7:24:36 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 3 of 4
Certificate Number: 17-HS1686631-PDA

ABS Programs
ABS has used due diligence in the preparation of this certificate and it represents the information on the product in the ABS Records as of the
date and time the certificate was printed. Type Approval requires Drawing Assessment, Prototype Testing and assessment of the
manufacturer's quality assurance and quality control arrangements. Limited circumstances may allow only Prototype Testing to satisfy Type
Approval. The approvals of Drawings and Products remain valid as long as the ABS Rule, to which they were assessed, remains valid. ABS
cautions manufacturers to review and maintain compliance with all other specifications to which the product may have been assessed. Further,
unless it is specifically indicated in the description of the product; Type Approval does not necessarily waive witnessed inspection or survey
procedures (where otherwise required) for products to be used in a vessel, MODU or facility intended to be ABS classed or that is presently in
class with ABS. Questions regarding the validity of ABS Rules or the need for supplemental testing or inspection of such products should, in all
cases, be addressed to ABS.

01/29/2018 7:24:36 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 4 of 4

Você também pode gostar