Você está na página 1de 1

LEMBAR KERJA

SAND CONDITION ANALYSIS


REF : The last version of WI-TSE-04-06, WI-TSE-04-07, WI-TSE-04-08 WI-TSE-04-09, WI-TSE-04-014

SAMPLE IDENTIFICATION
Sample Number 6807. Date Received 3/5/2019
Sample Source SAND JAMBI - TM Date Tested 3/5/2019
Sent By CILEGON Tested by AGUNG PERMANAH
Type of Test Regular Prepared by AGUNG PERMANAH
Testing Location Lab SRMI Plant Kebon Nanas
TEST RESULT
Item Reference Standard Result
Passing Mass No. 200, % AS 1141-12, WI-TSE-04-06 max. 5 1.62
Fineness Modulus ASTM C 136, AS 1141.11, WI-TSE-04-07 2.30 - 3.10 2.61
Water Absorption, % ASTM C 128, JMX WI-TSE-04-08 max. 5 2.54
Specific Gravity ASTM C 128, JMX WI-TSE-04-08 min. 2.5 2.55
Organik Impurities ASTM C 40, WI-TSE-04-09 max no. 3 no. 3

SIEVE ANALYSIS
Reference : ASTM C33-93, ASTM C136, AS 1141-11, JMX WI 044
Sieve Aperture Retained Mass
(mm) (gram) Σ % Retained Σ % Passing
9,5 0 0 100
4,75 8 0.66 99.3
2,36 75.3 6.21 93.8
1,18 275.1 22.7 77.3
0,6 631.8 52.1 47.9
0,3 994.2 82.0 18
0,15 1181.5 97.5 2.52
Pan 1212

Sand Grading Curve


Reference ASTM C33-93
100
90
80
70
% Passing

60
50
40
30
20
10
0
0.08 0.15 0.3 0.6 1.18 2.36 4.75 9.5
Sieve Aperture (m m )

M ax M in Result

Diperiksa Oleh: Diketahui Oleh:

Joel Alfonso Manurung Abdurakhman Rasyid


Product Development Engineer Product Development Sec Manager

No. Doc: WS-TSE-04-06-02.1 No. Rev: 1 Date: 12 Februari 2015 Page 1 of 1


Controlled Copy, Do Not Duplicate -- For Internal Use Only