Você está na página 1de 2

PHILIPPINE TONAN CORPORATION

Cebu Factory(Main)
3rd St., Mactan Economic Zone 1,
Ibo, Lapu - Lapu City, Cebu 6015, Philippines

Date (Month/Day) :
Model : Serial No.: Machine No.:
ANNUAL GENERATOR INSPECTION CHECKLIST
NO. CHECK ITEMS INDICATE STATUS REMARKS
COOLING SYSTEM
1 Engine coolant level G/NG
2 Radiator core/heat exchanger G/NG
3 Coolant lines/connections/hoses G/NG
4 Water jacket heater(s) G/NG
D.C. ELECTRICAL SYSTEM
5 Battery(s) electrolyte level G/NG
6 Battery comparment G/NG
7 Battery connections/cables/casing G/NG
8 Shutdown mechanism G/NG
9 Elecrical Starter/alternator G/NG
10 Elecrtrical system, accessories & components G/NG
A.C. ELECTRICAL SYSTEM
11 A.C wiring G/NG
12 Battery charger G/NG
13 Control panel/ switch gear G/NG
14 AC generator voltage regulator G/NG
15 Electrical system, accessories & components G/NG
AIR INDUCTION & EXHAUST SYSTEM
16 Air cleaner units G/NG
17 Air induction piping and connections G/NG
18 Turbocharger/blower G/NG
19 Exhaust manifold/piping/connections G/NG
POWER UNIT
20 Generator structure G/NG
21 Clutch assembly (power take off) G/NG
22 Couplings G/NG
LUBRICATION SYSTEM
23 Engine oil level G/NG
24 Engine oil filter G/NG
25 Crankcase G/NG
26 Oil leaks(hoses, connectors) G/NG
27 Engine governor oil level G/NG
28 Fan drive bearings G/NG
29 Generator bearings G/NG
30 Gauges & safety mechanism G/NG
31 Accessory drives G/NG
FUEL SYSTEM
32 Fuel level G/NG
33 Fuel filters G/NG
34 Fuel system components/hoses/piping G/NG
35 Gauges & safety mechanism G/NG

LEGENDS GENSET ACTUAL RUNNING HOURS


G Good NG Not Good GENSET LOAD TEST(20mins)

Inspected by: Noted by:

Technician/Maintenance Personel Maintenance Supervisor

Você também pode gostar