Você está na página 1de 7

CURRICULUM VITAE

Name : ANANDABABU.U
Experience : 5.3Years
Position : Electrical Senior T&C Engineer
Nationality : Indian
E mail : babueee92@gmail.com
Mobile : +916303870027 (IND) ,+ 917502175733.

CARREER SUMMARY
Practical site work experience in Testing & Commissioning upto 765KV CRP Panels at
SIEMENCE LTD in Goa & Mumbai .I have handled Schneider Smart Grid SCADA & ADMS,NMS
networking Engg.Config of DELL servers(hardware/software), 400kv Switch yard Commisioning & GIS
exp also I have and creating Database,ICCP,FEP and RTU integration to SCADA. High Voltage, Low
Voltage Switch Gear, Relay Control Panels, Schemes, Motors , Switchgear control Interlocks ,FRTU
Field Engg T&C,IEC60870-104 Protocal & BCU Signal preparations has been done,.
PROFESSIONAL QUALIFICATION
 Diploma In Electrical & Electronics Engineering
Year of completion : April 2010
 Diploma In Automation ( PLC , SCADA )
Year of completion : April 2010

CAREER HISTORY

Organization :PDCS india Projects pvt ltd., India.


Designation : Testing & Commissioning Engineer
Period : Jan 2014 to July 2018 till now

TEST KIT FAMILIARITY


 AEL make AC High voltage test kit (0-100 kV ).
 Tan Delta kit (DELTA 4100,M4100) of Megger and Double,
 Scope CB Timing Test Kit & DCRM Kit.
 Primary Injection tester various types
 Scope MUT4 and Programma Timer Test Kit
 BM 11, 21 AVO Insulation Resistance Tester
 Primary Injection kit – Techno products, SUDARSAN, MEGGER 100
 Secondary injection Kit –SUDARSAN,Omicron CMC256
 CB Timing Test Kit – SCOPE, Technoproduct
 Insulation Resistance Tester – Meggar, KYORITSU, FLUKE
 High voltage test Kit – AEL make, lctech
 CRM KIT-SCOPE
 High voltage kit dc hipot
 High voltage kit vlf hipot
 Omicron cmc 356
Page 1 of 7
PROFESSIONAL EXPERIENCE - PROJECTS INDIA
Hyderabad Metro RailwayLtd(HMRL).
Metro projects Experience;

 HMRL –From all metro stations RTU’s communicated into control center & SCADA
Integration has been done.
 Micom relay &Fcom relay integration &modbus configurations has been done.
 SCADA signals local testing &E2E testing has been done.
 Testing transformer of 20MVA(Oil type) power transformer
3MVA,630KVA,1500KVA (Dry type) Distribution transformer has been done.

SCHEMES HANDLED:

 ABB
 BHEL
 SIEMENS
 ALSTOM
 SCHNIDER ELECTRIC
 L&T
 NARI
 PRAVEEN

RELAY SOFTWARE TOOLS HANDLED:

 AREVA – Micom S1 Studio.


 SIEMENS _ DIGSI4.90

SAS & ADMS SOFTWARES HANDLED;


CAT TOOL C264
S2K, XML PERSER,SMT,SCE,
PACIS OI.
For NMS_EVEREST Software,
For ADMS_) DMD RT,DMD NETWORK BUILDER,
DMD STG.,
For Metro Project_CLEAR SCADA VIEW X.

ADMS/NMS R-APDRP Project 1.3Year Experience in KERALA ;


 For (Triventrum ,Ernakulam, Kozhikode) city under R-APDRP Project.
Maintaining the data/database/Software implement and backups for SCADA/DMS
and FEP& ICCP,
 Techroutes Router, EFswitch and various peripheral devices.
 DMS/SCADA system problem identification and root cause analysis to determine
whether the fault is hardware or software and resolve the problem.
 Working knowledge of all phases of SCADA System Master Station and, consisting
of Servers, Front End Processors, Workstations, Displays, Remote Terminal Units,
Interface to Telecom Equipment, and all Associated SCADA Software Applications.
 FRTU Configurations & CMS Modem configuration has been done.
Page 2 of 7
 RVDU Router confic & control center vpn config has been done.

 All/controlcenter/equipments/like
(router,server,switch,firewall,workstations,)Discovered by NMS everest software
and graphics has been done.
a) MFT Configuration

b) Local Testing of the FRTU Signals (Internal Testing only before E2E Testing)

c) Communication with SCADA/DMS Control Center

d) E2E Testing with Control Center (With Customer)

e) E2E Testing with Control Center (With Customer)

a) E2E Testing with Control Center (With Customer)

 These RMU Type / Configuration cable scheme preparation has been done.

SAS T&C EXPERIENCE;

 Substation automation system supporting engineer to T&C Retrofitting of


400/220/132Kv gejwel substation in Hyderabad,
 Co-ordination with vendors attending the discussion with the client,modification of
schemes as build BCU signals drawing preparations,
 Co-ordinate with RTU,SCADA To ensure that the correct cable is connecting for
signaling,
 BCUs & Switch yard Signels prepation for as per customer requirements
 Cable schedule preparation has to be prepared as per the drawing,
 FRTU Configurations & MFT Configuration has been done,
 FRTU to RMU Wiring connections and signel preparetions as per customer
requirements,
 CMS –3G modem configurations has been done.
 ROUTER configurations ,LDMS PC Security configurations,
 FRTU E2E testings has been done,
 MFT For FRTU Configurations also..,

FACTORY TESTING

SIEMENS LTD,(GOA),INDIA..,

 Interpanel chart preparing and scheme modifications.


 I have 6 months testing experienced in( SIEMENSE Factory Verna at Goa) upto 11kv to 765
CRP panel scheme logics good experienced.
 DC Logic & AC Logics, CT, PT Secondary injection has to been done.
 All operations as per the scheme & any modification or correction has to been checked.

NR ELECTRIC CO. PVT. LTD., PANVEL, MAHARASHTRA, INDIA..,

 I have 6 months testing experienced in(NR ELECTRIC Factory Panvel At Mumbai) upto.
 DC Logic & AC Logics, CT, PT Secondary injection has to been done.
 All operations as per the scheme & any modification or correction has to be checked.
Page 3 of 7
 Interpanel chart preparing and scheme modifications

 11kv to 765 CRP panel scheme logics good experienced

ERECTION TESTING & COMMISIONING;


JINDAL POWER LTD, THERMAL POWER PLANT (4×250MW),CHATTISGHAR

 6.6KV CT,PT,Breakers ErectionT&C experienced.

HT& LT EQUIPMENTS TESTING EXPERIENCE;


RELIENCE LTD, GUJARAT, JAM NAGAR.

 Testing and commissioning of ESP, CHP, Boiler MCC, Station service MCC and
Emergency PMCC LT panels.
 I have 7 month experienced in CT, PT ,BREAKER, Testings of HT Switch gear Panels
handled in Relience ltd.., Jamnagar ,Gujarat.

SPECIALIZED SKILLS:

Testing & Commissioning:

 Relay & Control panels

 LT panel including all CT,PT,Breker testing and commissioning.


 HT panel including all CT,PT,Breker testing and commissioning..,

EXPERIENCE WITH RELAYS ;

 .FIRMARE UPDATION Of P141,P143,P543 & SIEMENSE DIGCI 5.0.. Initialization


Such the 7SJ60,7SJ61,7SJ62 Relays.
 O/C , E/F Relays has been tested.

BASIC KNOWLEDGE OF PROTECTION ;


1. Distance protection
2. Trafo differential protection
3. Busbar protection
4. Line differential protection

PROJECTS IN INDIA:

CLIENT : PGCIL(ORAI) UPGCIL


PROJECT : 765/400/33KV ORAI GIS S/S Tie,Ict,Bus Reactor,Line CRP With A/R
Schemes Quality checking and schemes modification.
CUSTOMER ; Siemense india ltd ,Goa.

CLIENT : Relience ltd,Jamnagar,Gujarat.


PROJECT : 6.6Kv HT Switch Gear Panels Testing &Commissioning,
CUSTOMER : Schneider Electric infrastructure ltd,Vadodara,Gujarat.

CLIENT : JSW Jindal power ltd at Raighar inChattisghar.


PROJECT : 6.6Kv HT Panels CT and Breakers (Erection Testing and Commissioning)
CUSTOMER : Schneider Electric infrastructure ltd,Chennai.

Page 4 of 7
CLIENT : Kerala State Electricity Board,Trivendrum Kerala,
PROJECT : (FRTU Field Testing and Commissioning),
CUSTOMER : Schneider Electric infrastructure ltd,Chennai.

CLIENT : TSTRANSCO.
PROJECT : HMRL-Hyderabad metro rail ltd, (SAS Testing and Commissioning)
CUSTOMER : Schneider Electric infrastructure ltd,Chennai.

CLIENT : TSTRANSCO.
PROJECT : 400/220/132 SAS Retrofitting, (SAS Testing and Commissioning)
CUSTOMER : Schneider Electric infrastructure ltd,Chennai..

CLIENT :KSEB ,KERALA.


PROJECT :SCADA, DMS Integration with RMU, (FRTU Testing and Commissioning)
CUSTOMER : Schneider Electric infrastructure ltd,Chennai..

CLIENT : TSTRANSCO.
PROJECT : 400/220/132 Kalpaka Substation,(125kvar Reactor Bay Switch Yard Testing and
commissioning) ,
CUSTOMER : ALSTOM India ltd in Chennai..

CLIENT :KSEB ,KERALA.


PROJECT :SCADA, DMS Integration with RMU, (FRTU Testing and Commissioning)
CUSTOMER : Schneider Electric infrastructure ltd,Chennai..

Maintanence Experience,

EMPLOYER ; PDCS india projects p ltd,Chennai,


CLIENT : SCHNIDER ELECTRIC LTD,CHENNAI.
POSITION: Operation and Maintanence Engineer,
CUSTOMER: V.O.C PORT TRUST THERMAL POWER PLANT (5 UNITs 1050MW) ,
WORKING PLACE; TuticorinIN Tamilnatu.

1. Worked as a Maintanence Engineer,


2. Teasting of CT,PT,Breaker,CVT,Switchgear & power transformer operation and maintanence of
power and substations,
3. Trouble shooting of Electrical circuits.

SWITCH YARD EXP;

1. CT,CVT Testing done on 765KV UAT on SHRAVANTHI POWER LTD-KASHIPUR,


2. Energy meters caliberations done for Schneider Electric EM6400 Meters,
3. DCRM Testing done for 400KV SIEMENCE Breaker @HVDC PLANT,Alipurduar
4. DCRM Testing done for 400KV ALSTOM Breaker @HVDC PLANT,Kurukshetra,
5. DCRM Testing done for 800KV HVDC Breaker @HVDC PLANT,Kurukshetra,
6. DCRM Testing done for 400KV & 220KV @Chanditala,Howrah,
7. TANDELTA Testing done for 145MVA Trafo,

Page 5 of 7
8. 125MVAR Shunt Reactor and 160MVA trafo stablity testing also done.
9. 125MVAR Reactor SFRA Testings has been done,
10. TANDELTA Testing performed for 400KV CT,CVT at NTPC in Chakabura,Chhatisgarh,
11. Motor Testing performed for 425kw CGL make motor at RAMCO CEMENT

CIRCUIT BREAKER ANALYZER test upto 765KV;

1. Breker Timing done for 765KV & 800KV HVDC Breaker,ALSTOM-SIEMENCE,


2. Operating timing contacts ,auxiliary contacts,
3. Dynamic contact resistance measurement (DCRM) for SF6 Circuit breaker upto ±800KV
Breakers,
4. Contact travel measurement (contact travel wipe leanth ,total contact incertion)
5. Coil resistance check (trip coil and closing coil),PD check,
6. Static contact resistance measurement for main contacts,
7. Duty cycle check ,pole discrepancy check pickup voltage of the coils

Testing done for CT,CVT,PT upto 765KV;

1. Insulation resistance measurement


2. TANDELTA test,
3. Winding resistance test
4. Knee point voltage and Excitation Current test,
5. Radio test,
6. Polarity test

Page 6 of 7
PERSONAL DETAILS
Date of Birth : 15 June 1992
Marital Status : Single
Father’s Name : P.Ukkaravel
Languages Known : Tamil, English
Passport No. : M0759731
E mail : babueee92@gmail.com
Mobile number : +917502175733 & +916303870027
Permanent address : mutapuliyan Street, keezhmampattu (post),
Cuddalour (DT), Pin-607106, Tamil Nadu, India.
DECLARATION:

I hereby declare that the particulars of information and facts stated here in above are true, correct
and complete to the best of my knowledge and belief.

Yours sincerely
(ANANDABABU.U)

Page 7 of 7

Você também pode gostar