Escolar Documentos
Profissional Documentos
Cultura Documentos
VENTILADOR CENTRÍFUGO
2019 – I
INDICE
1. INTRODUCCIÓN ____________________________________________________ 3
2. OBJETIVOS ________________________________________________________ 4
3. FUNDAMENTO TEÓRICO _____________________________________________ 5
4. QUIPOS UTILIZADOS ________________________________________________ 8
5. PROCEDIMIENTO __________________________________________________ 10
6. DATOS EXPERIMENTALES ___________________________________________ 11
7. CÁLCULOS Y RESULTADOS __________________________________________ 13
8. GRÁFICAS ________________________________________________________ 15
9. CONCLUSIONES ___________________________________________________ 16
10. BIBLIOGRAFÍA ____________________________________________________ 17
TIPOS DE PRESIÓN
PRINCIPIO DE BERNOULLI
Donde:
Donde:
TIPOS DE FLUJO
Motor Eléctrico:
Marca: US ELECTRIC MOTOR
Pot. Placa: 2HP
Voltaje: 230/460 v
Intensidad: 7.2/3.6 A
Velocidad: 1600rpm
Frecuencia: 60 Hz.
En primer lugar, se fijó con el tacómetro una velocidad de giro del motor
(valores cercanos a 2500 RPM, 2000 RPM, 1800RPM y 1500 RPM)
.
Una vez definida la velocidad, se reguló la posición del cono en la salida
del flujo de aire.
Luego, con ayuda del tubo de Pitot y el manómetro digital se midió las
presiones totales y estáticas del aire de tal modo que la presión de
velocidad sea siempre máxima (punto de medida casi a la mitad del
cilindro).
1260 RPM
PUNTO F(Lb) P(mmH2O) Pv(mmH2O)
1 0.6 25.2 0.2
2 0.67 16.9 1.6
3 0.6 11 2.6
4 0.75 8.1 3
5 0.78 6.2 2.9
6 0.79 5.3 3.5
7 0.79 4.7 3.7
8 0.79 4.3 3.6
1500 RPM
PUNTO F(Lb) P(mmH2O) Pv(mmH2O)
1 0.68 35.3 0.3
2 0.81 22.7 2.1
3 0.81 15.4 3.6
4 0.81 11.44 4.3
5 0.81 8.7 4.6
6 0.81 7.3 4.8
7 0.82 6.4 4.9
8 0.82 6 5.1
1800 RPM
PUNTO F(Lb) P(mmH2O) Pv(mmH2O)
1 1.1 51.5 0.2
2 1.2 34 1.5
3 1.15 22.5 4.9
4 1.15 17.3 6
5 1.15 13 6.8
6 1.15 11 7.2
7 1.15 9.6 7.4
8 1.15 9 7.6
2100 RPM
PUNTO F(Lb) P(mmH2O) Pv(mmH2O)
1 1.28 69.4 0.3
2 1.43 44.8 1.4
3 1.5 30 4.9
4 1.5 22 8
5 1.43 17.1 8.8
6 1.43 14.4 9.3
7 1.43 12.6 9.6
8 1.43 11.8 10
Para realizar los respectivos cálculos, se tomaron algunas consideraciones tales como:
𝑉𝑚á𝑥 2
𝑃𝑉 = 𝑃𝑇 − 𝑃𝐸 =
2𝑔
𝑉𝑚 = 0.82 ∗ 𝑉𝑚á𝑥
𝑉𝑚 ∗ 𝜋𝐷 2
𝑄=
4
𝑃𝑇
𝐻𝑉 = = 𝐻𝑎𝑖𝑟𝑒
𝛾𝑎𝑖𝑟𝑒
𝑃𝑒𝑗𝑒 = 𝐹 ∗ 𝑏 ∗ 𝑁
𝑃𝑎𝑖𝑟𝑒
𝑛=
𝑃𝑒𝑗𝑒
1500 RPM
Vm(m/s) Qaire (m3/s) H(m) Paire(W) Pm(W) nv(%)
1.9388 0.1415 33.5281 55.8369 105.7596 52.7961
5.1297 0.3743 21.5606 94.9995 125.9783 75.4094
6.7163 0.4901 14.6270 84.3836 125.9783 66.9826
7.3403 0.5356 10.8658 68.5088 125.9783 54.3814
7.5921 0.5540 8.2633 53.8870 125.9783 42.7748
7.7553 0.5659 6.9336 46.1880 125.9783 36.6635
7.8357 0.5717 6.0788 40.9133 127.5336 32.0804
7.9940 0.5833 5.6988 39.1311 127.5336 30.6830
1800 RPM
Vm(m/s) Qaire (m3/s) H(m) Paire(W) Pm(W) nv(%)
1.5831 0.1155 48.9149 66.5133 171.0817 38.8781
4.3354 0.3163 32.2934 120.2570 186.6346 64.4345
7.8357 0.5717 21.3706 143.8357 178.8581 80.4189
8.6707 0.6327 16.4316 122.3792 178.8581 68.4225
9.2307 0.6735 12.3475 97.9002 178.8581 54.7363
9.4983 0.6931 10.4479 85.2403 178.8581 47.6580
9.6293 0.7026 9.1181 75.4177 178.8581 42.1662
9.7586 0.7120 8.5482 71.6532 178.8581 40.0614
Altura vs Caudal
70
60
1260 RPM
50
1500 RPM
Altura (m)
40 1800 RPM
2100 RPM
30
20
10
0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
Caudal (m3/s)
Eficiencia vs Caudal
90 90.0000
80 80.0000
70 70.0000
60 60.0000
Eficiencia (%)
50 50.0000
40 40.0000
1260 RPM
30 30.0000
1500 RPM
20 20.0000
1800 RPM
10 10.0000
2100 RPM
0 0.0000
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
Caudal (m3/s))