BORZOUYEH PETROCHEMICAL CO. 4th AROMATICS PLANT Consortium Work No. : BA-0512
CONSORTIUM OF :
VENDOR DOCUMENT COVER
TEC SAZEH LG E&C
SHEET
INDEX
D D.L.L. H
M.L.L
Hb
L.L.L.L.
1
100
GEOMETRIC CAPACITY : VG
VG = × D2 × H = 23,169 m3
4
NET CAPACITY : VN
VN = × D2 × ( M.L.L) = 21,174 m3
4
VM = × D2 × × ( M.L.L ) - × D2 × × Hb ( H.L. ) + × D2 × Hb
4 3 12
= 21,061 m
Where,
td : Design shell thickness, in mm
tt : Hydrostatic test shell thickness, in mm
D : Nominal diameter of tank, in m
D = 44.2 m
H’ : Height from bottom of course under consideration to design liquid level
including design internal pressure. (m)
= H+P/G
H : Height from bottom of course under consideration to the design liquid
level. (m)
P : Design pressure = 0.02 barg = 0.204 mAq.
G : Design specific gravity of the liquid to be stored = 0.846
Gravity of hydrostatic test water = 1.023
c : Corrosion allowance, in mm
c = 3 mm for 1st. shell
c = 2.5 mm for 2nd. and above shell
M = ZI (C1 Ws Xs + C1 Wr Ht + C1 W1 X1 + C2 W2 X2)
Where,
C1 : Lateral earthquake force coefficient ....................... 0.6
C2 : Lateral earthquake force coefficient determined per
API ST’D 650 appendix E para. E.3.3. .................. 0.06825
When T is less than or equal 4.5 : C2 = 0.75 S/T
When T is greater than 4.5 : C2 = 3.375 S/T2
Where, T = Natural period of first mode sloshing, in
seconds. T may be determined from the
following equation.
T = KD1/2 = 7.70336 (sec)
K = Factor obtained from figure E-4 of API st’d
650 app’x E for the ratio D/H .... 3.2029
Ws : Total weight of tank shell 2,359 KN
Xs : Height from bottom of tank shell to center of gravity of shell
6.548 m
Wr : Total weight of tank roof 1,341 KN
Ht : Gravity center of roof 18.061 m
W1 : Weight of effective mass of tank contents which moves in unison with
tank shell 62,846 KN
File : C:\DOCUME~1\gs\LOCALS~1\Temp\_AZTMP35_\C3363FD012(1).doc / 148 kB
TKK JOB NO.
REV.
TOYO KANETSU K.K. SPEC. NO. C3363F-D-01 2
T01-3363 TOKYO, JAPAN
SHEET NO. 7 OF 43
Where,
WL : Maximum weight of tank contents of shell circumference which may be
utilized to resist the shell overturning moment N/m
tb : Thickness of the annular bottom plate after corroded
= 9-3 = 6 mm
Fby : Minimum specified yield strength of annular bottom plate
205 MPa
Then,
WL = 2.906 × 104 N/m
1) Unanchored tank
The maximum longitudinal compression force at the bottom of the shell may be
determined as follows
M
2
< 0.785
D (Wt + WL)
b 1.273 M
c = = (Wt + ) / 1,000t
1,000t D2
M
0.785 < 2
< 1.5
D (Wt + WL)
b + WL
obtained from figure E-5 (API 650)
Wt + WL
b
c =
1,000t
M
1.5 < 2
< 1.57
D (Wt + WL)
M
1.57 < 2
D (Wt + WL)
b 1.273 M
c = = (Wt + ) / 1,000t
1,000t D2
Where,
c : The maximum longitudinal compressive stress in the shell
N/mm2
b : Maximum longitudinal shell compression force of shell circumference
1.336 × 105 N/m
Wt : Weight of tank shell and portion of roof supported by shell
2.664 × 104 N/m
M
1.57 > 2 = 1.192 > 0.785
D (Wt + WL)
c = 7.26 N/mm2
G H D2
> 44
t2
83 t
Fa = < 0.5 Fty
D
G H D2
< 44
t2
83 t
Fa = + 7.5 G H < 0.5 Fty
2.5 D
Where,
Fa : Maximum allowable longitudinal compressive stress in the shell
N/mm2
t : Thickness of the bottom shell course, excluding any corrosion allowance
18.4 mm
Fty : Minimum specific yield strength of the shell
205 MPa
G H D2
= 67 > 44
t2
Fa = 35.47 N/mm2
c < Fa
5.1 The maximum height of unstiffened shell length shall not exceed the following value
according to API ST’D 650 10TH EDITION, 1998 para. 3.9.7.
Where,
H1 : Max. height of unstiffened shell, in mm
t : Top shell thickness in height H1, in mm
t = 8 mm
D : Nominal tank diameter, in m
D = 44.2 m
V : Wind velocity, mile/hour
Refer to doc. no. G3363-D-01
V = 44.6 m/sec.
= 99.8 mile/hr
Wtr = W × ( t / t act.)5
WE = Wtr
Where,
Wtr : Transposed width of each shell, in mm
W : Actual width of each shell, in mm
t act. : Actual shell thickness, in mm
WE : Total transposed width of shell, in mm
Result of Calculation
Applicable Code --- API ST’D 650 10TH EDITION, 1998 Para. 3.9.7
The required minimum section modulus of intermediate wind girder shall be determined
by the following equation.
Where,
Zws : Required min. section modulus, in cm3
D : Nominal tank diameter, in m = 44.2 m
H1 : Vertical distance between the intermediate wind girder and
compression ring, in m = 2.0 m
V : Wind Velocity, in mile per hour = 99.8 MPH
(44.6 m/sec.)
Actual section modulus Zas of intermediate wind girder as drawn below is,
1
252
L150×150×12
2
12
240
8.0
A Y A·Y A·Y2 Io
(cm2) (cm) (cm3) (cm4) (cm4)
1 40.32 15.4 620.9 9,562 2
2 34.77 4.14 143.9 595 740
Then,
y = (A · Y) / A = 10.18511 cm
I = ( A · Y2 + Io ) - A × y2 = 3,109 cm4
e = 12.16817 cm
Where,
As : Shell projectional area
As = H1 D m2
H1 : Shell height m
Ar : Roof projectional area m2
Hs : Center of gravity height for As m
Hr : Center of gravity height for Ar m
P : Wind pressure
(Refer to doc. no G3363-D-01)
2 Ww D
Tw = × kN-m
3 2
Where,
D : Tank inside dia. m
Ww : Weight of shell (after corroded) and dead weight supported by the
shell (excluding uplift from internal operating pressure) KN
P D H1 Hs Hr
(N/m2) (m) (m) (m) (m)
1,214.2 44.2 15.1 7.55 17.49
As Ar Mw Ww Tw
(m2) (m2) (KN-m) (KN) (KN-m)
668 177 9,883 1,338 19,713
Mw < Tw
2) Corrosion allowance
Roof plate = 1.5 mm
Roof structure = 0.75 mm
(Each side)
72 R4 Rafter
72 R3 Rafter
72 R2 Rafter
4,350 36 R1 Rafter
5,030
5,300
5,420
R2,000
R7,420
R12,720
R17,750 36 G1 Girder
72 G2 Girder
Center ring
72 G3 Girder
R22,100
R44,200
44,200
LR
Wi = ( r22 p + W’) / N (N)
r1/2
Hi Where,
h2 Wi p : Design load (N/m2)
h1
Point W’: Weight of center ring, etc. (to r2) (N)
N : Number of rafter
Hi
q1 = 2 r1p / N (N/m)
q2 = 2 r2p / N + Wg (N/m)
R
Where,
Wg = w × LR / r1 (N/m)
w : Weight of rafter (N/m)
A1 = r1 × q1 / 2 (N)
r1 r2 A2 = r1 × q2 (N)
r0
h1 = R2 - r22 - R2 - r02 (m)
q2 A2
Horizontal force
Hi = (Wi × r1 + A1 × r1 / 3 + A2 × r1 / 2) / h1
r1
(N)
Maximum bending moment at point “m”
Mmax.= (Wi × r1/2 + q1r12/48 + q2r12/8 - Hi × h2)
× 100 (N-cm)
Nominal force at point “m”
Vi = Wi + q1 × r1 / 8 + q2 × r1 / 2 (N)
Point
Axial force at point “m”
T
Hs = Hi × cos + Vi × sin (N)
Hs
Hi
Mmax.
Sb = z
Axial stress
Hs
Sc =
A
Where,
Z : Section modulus of rafter (cm3)
A : Section area of rafter (cm2)
Sb Sc
+ < 1
b c