Demetrio Carranza Peña

INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

ANALISIS GRANULOMETRICO POR TAMIZADO ASTM D 6913

SOLICITANTE PROESTECH

PROYECTO CALLES HUAMACHUCO

CALICATA MUESTRA 01 FECHA 09/04/2019


MUESTRA M-1 CLASE DE SUELO ARCILLA GRAVOSA

Tamiz Abertura Peso % Parcial % Retenido % Que Peso de la muestra 2000.00 gr


# mm reten. (gr) retenido acumulado pasa Peso seco lavado 1340.29 gr
3" 76.200 Pedida por lavado 659.71 gr
2 1/2" 63.500 100.0 Limites de Consistencia
2" 50.300 0.0 0.0 0.0 100.0 Limite liquido 24.04 %
1 1/2" 38.100 0.0 0.0 0.0 100.0 Limite plastico 16.00 %
1" 25.400 76.0 3.8 3.8 96.2 Indice de plasticidad 8.04 %
3/4" 19.050 56.0 2.8 6.6 93.4 % de material
3/8" 9.525 180.0 9.0 15.6 84.4 Grava 26.1 %
#4 4.760 209.0 10.5 26.1 74.0 Arena 40.9 %
# 10 2.000 210.0 10.5 36.6 63.5 Fino 33.1 %
# 20 0.840 128.0 6.4 43.0 57.1 Humedad 11.52 %
# 40 0.426 71.0 3.6 46.5 53.5 Clasif. SUCS CL
# 60 0.250 107.0 5.4 51.9 48.2 Clasif. AASTHO A-2-4 (0)
# 100 0.149 136.0 6.8 58.7 41.4 Coheficientes
# 200 0.075 165.0 8.3 66.9 33.1 D10 mm ----
Plato 662.0 33.1 100.0 0.0 D30 mm ----
Sumatoria 2000.00 D60 mm ----
Cu ----
Cc ----

CURVA GRANULOMETRICA
Cc
100
Porcentaje que pasa %

90
80
70
LL
60
LP
50 IP
40
30
20
10
0
100.00 10.00 1.00 0.10 0.01
Abertura (mm)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

LIMITES DE CONSISTENCIA MALLA 200 ASTM D4318


SOLICITANTE PROESTECH

PROYECTO CALLES HUAMACHUCO

CALICATA MUESTRA 01 FECHA 09/04/2019


MUESTRA M-1
PROF (m): 1.50

LIMITE PLASTICO LIMITE LIQUIDO

PRUEBA Nº 1 2 1 2 3

FRASCO Nº --- --- --- --- ---

Nº DE GOLPES 15 25 33

PESO DEL FRASCO (gr) 16.240 13.110 16.550 11.350 10.800

1 PESO FRASCO + SUELO HUMEDO (gr) 22.520 17.700 43.030 48.210 45.650

2 PESO FRASCO + SUELO SECO (gr) 21.650 17.070 37.520 41.020 39.350

4 PESO AGUA (1-2) (gr) 0.870 0.630 5.510 7.190 6.300

5 PESO SUELO SECO (2-3) (gr) 5.410 3.960 20.970 29.670 28.550

6 CONTENIDO DE HUMEDAD(4/5*100) (%) 16.081 15.909 26.276 24.233 22.067

L.P. = 16.00 L.L. = 24.04

I.P. = 8.04

DIAGRAMA DE FLUIDEZ
30

29

28
Contenido de humedad %

27

26

25

24

23

22

21

20
15 17 19 21 23 25 27 29 31 33 35
N° de Golpes

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

ANALISIS GRANULOMETRICO POR TAMIZADO ASTM D 6913

SOLICITANTE PROESTECH

PROYECTO CALLES HUAMACHUCO

CALICATA MUESTRA 02 FECHA 09/04/2019


MUESTRA M-1 CLASE DE SUELO ARCILLA LIMOSA CON GRAVA

Tamiz Abertura Peso % Parcial % Retenido % Que Peso de la muestra 2000.00 gr


# mm reten. (gr) retenido acumulado pasa Peso seco lavado 1384.19 gr
3" 76.200 Pedida por lavado 615.81 gr
2 1/2" 63.500 100.0 Limites de Consistencia
2" 50.300 0.0 0.0 0.0 100.0 Limite liquido 22.49 %
1 1/2" 38.100 0.0 0.0 0.0 100.0 Limite plastico 17.41 %
1" 25.400 101.0 5.1 5.1 95.0 Indice de plasticidad 5.08 %
3/4" 19.050 131.0 6.6 11.6 88.4 % de material
3/8" 9.525 180.0 9.0 20.6 79.4 Grava 31.2 %
#4 4.760 211.0 10.6 31.2 68.9 Arena 38.0 %
# 10 2.000 182.0 9.1 40.3 59.8 Fino 30.9 %
# 20 0.840 108.0 5.4 45.7 54.4 Humedad 11.97 %
# 40 0.426 63.0 3.2 48.8 51.2 Clasif. SUCS SC-SM
# 60 0.250 103.0 5.2 54.0 46.1 Clasif. AASTHO A-2-4 (0)
# 100 0.149 145.0 7.3 61.2 38.8 Coheficientes
# 200 0.075 158.0 7.9 69.1 30.9 D10 mm --
Plato 2.2 0.1 69.2 30.8 D30 mm --
Sumatoria 1384.19 D60 mm --
Cu --
Cc --

CURVA GRANULOMETRICA
Cc
100
Porcentaje que pasa %

90
80
70
LL
60
LP
50 IP
40
30
20
10
0
100.00 10.00 1.00 0.10 0.01
Abertura (mm)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

LIMITES DE CONSISTENCIA
SOLICITANTE PROESTECH

PROYECTO CALLES HUAMACHUCO

CALICATA MUESTRA 02 FECHA 09/04/2019


MUESTRA M-1
PROF (m): 1.50

LIMITE PLASTICO LIMITE LIQUIDO

PRUEBA Nº 1 2 1 2 3

FRASCO Nº --- --- --- --- ---

Nº DE GOLPES 17 24 31

PESO DEL FRASCO (gr) 13.390 13.090 17.250 12.600 12.120

1 PESO FRASCO + SUELO HUMEDO (gr) 17.610 18.090 41.340 43.570 40.060

2 PESO FRASCO + SUELO SECO (gr) 17.000 17.330 36.480 37.830 35.310

4 PESO AGUA (1-2) (gr) 0.610 0.760 4.860 5.740 4.750

5 PESO SUELO SECO (2-3) (gr) 3.610 4.240 19.230 25.230 23.190

6 CONTENIDO DE HUMEDAD(4/5*100) (%) 16.898 17.925 25.273 22.751 20.483

L.P. = 17.41 L.L. = 22.49

I.P. = 5.08

DIAGRAMA DE FLUIDEZ
26

25

24
Contenido de humedad %

23

22

21

20

19

18

17

16
15 17 19 21 23 25 27 29 31 33 35
N° de Golpes

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

PROCTOR Y CBR MUESTRA N° 1

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

ENSAYO PROCTOR MODIFICADO


MTC E 115 - ASTM D 1557 - AASHTO T-180 D

SOLICITANTE : DISTRIBUIDORA NORTE PACASMAYO SRL :


PROYECTO : INGº RESP. :
MUESTRA : SUBRASANTE - MUESTRA 01 FECHA : 09/04/2019
CANTERA : HECHO POR :
PRODUCCION : DEL KM :
UBICACIÓN : CALLES -HUAMACHUCO AL KM :
COMPACTACIÓN
MÉTODO DE COMPACTACIÓN : "B"
NUMERO DE GOLPES POR CAPA : 25
NUMERO DE CAPAS : 5
NÚMERO DE ENSAYO 1 2 3 4
PESO (SUELO + MOLDE) (gr) 6100 6241 6314 6244
PESO DE MOLDE (gr) 4177 4177 4177 4177
PESO SUELO HÚMEDO (gr) 1923 2064 2137 2067
VOLUMEN DEL MOLDE (cm 3) 948 948 948 948
DENSIDAD HÚMEDA (gr/cm 3) 2.028 2.177 2.254 2.180
DENSIDAD SECA (gr/cm 3) 1.910 2.017 2.065 1.970
CONTENIDO DE HUMEDAD
RECIPIENTE Nº s/n s/n s/n s/n
PESO (SUELO HÚMEDO + TARA) (gr) 93.17 114.01 106.95 97.29
PESO (SUELO SECO + TARA) (gr) 88.47 106.84 99.37 89.52
PESO DE LA TARA (gr) 12.89 16.80 16.54 16.74
PESO DE AGUA (gr) 4.70 7.17 7.58 7.77
PESO DE SUELO SECO (gr) 75.58 90.04 82.83 72.78
CONTENIDO DE HUMEDAD (%) 6.22 7.96 9.15 10.68
MÁXIMA DENSIDAD SECA (gr/cm 3) 2.065 ÓPTIMO CONTENIDO DE HUMEDAD (%) 9.24

CURVA DE COMPACTACIÓN Generar Gráfico

2.180

2.100
DENSIDAD SECA (gr/cm3)

2.020

1.940

1.860

1.780

1.700
4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0

CONTENIDO DE HUMEDAD (%)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
LABORATORIO MECANICA DE SUELOS CONCRETOS Y PAVIMENTOS
RELACION DE SOPORTE DE CALIFORNIA (C.B.R.)
(NORMA MTC E-132, AASHTO T-193, ASTM D 1883)
SOLICITANTE DISTRIBUIDORA NORTE PACASMAYO SRL :
PROYECTO INGº RESP. :
MUESTRA SUBRASANTE - MUESTRA 01 FECHA : 09/04/2019

CANTERA HECHO POR


:
PRODUCCION DEL KM :
UBICACIÓN CALLES -HUAMACHUCO AL KM :
DATOS DEL PROCTOR
MAXIMA DENSIDAD SECA : 2.065 g/cm3 CAPACIDAD : 10000 Lbs.
OPTIMO CONTENIDO DE HUMEDAD : 9.24 % ANILLO : 1

ENSAYO DE CBR
MTC E 132 - ASTM D 1883 - AASHTO T-193
Molde Nº 4 8 11
Nº Capa 5 5 5
Golpes por capa Nº 56 25 12
Cond. de la muestra NO SATURADO SATURADO NO SATURADO SATURADO NO SATURADO SATURADO

Peso molde + suelo húmedo (gr) 13245 11632 13005 11539 12763 11864
Peso de molde (gr) 8470 8470 8476 8476 8476 8476
Peso del suelo húmedo (gr) 4775 3162 4529 3063 4287 3388
Volumen del molde (cm3) 2102 2102 2102 2102 2104 2104
Densidad húmeda (gr/cm3) 2.272 1.504 2.155 1.457 2.038 1.610
Humedad (%) 9.97 16.08 9.47 16.12 9.52 16.19
Densidad seca (gr/cm3) 2.066 1.296 1.969 1.255 1.861 1.386
Tarro Nº S/N 65 S/N 67 S/N 69
Tarro + Suelo húmedo (gr) 118.10 1161.00 122.14 1073.10 106.25 1063.10
Tarro + Suelo seco (gr) 108.56 1043.00 112.75 967.00 98.34 958.00
Peso del Agua (gr) 9.54 118.00 9.39 106.10 7.91 105.10
Peso del tarro (gr) 12.84 309.00 13.62 309.00 15.24 309.00
Peso del suelo seco (gr) 95.72 734.00 99.13 658.00 83.10 649.00
Humedad (%) 9.97 16.08 9.47 16.12 9.52 16.19
Promedio de Humedad (%) 9.97 16.08 9.47 16.12 9.52 16.19

EXPANSION
TIEMPO EXPANSION EXPANSION EXPANSION
FECHA HORA DIAL DIAL DIAL
Hr. mm % mm % mm %
24/03/2019 16:00
25/03/2019 16:00 24 0.01 0.0 0.0
26/03/2019 16:00 48 0.01 0.0 0.0 0.26 0.0 0.0 0.05 0.0 0.0
27/03/2019 16:00 72 0.01 0.0 0.0 0.29 0.0 0.0 0.12 0.0 0.0
28/03/2019 16:00 96 0.02 0.0 0.0 0.35 0.0 0.0 0.17 0.0 0.0

0.004 % NO PRESENTA EXPANSIÒN

PENETRACION
CARGA MOLDE Nº 4 MOLDE Nº 8 MOLDE Nº 11
PENETRACION STAND. CARGA CORRECCION CARGA CORRECCION CARGA CORRECCION
pulg kg/cm2 Dial ( d iv) kg/cm 2 kg/cm 2 % Dial ( d iv) kg/cm 2 kg/cm 2 % Dial ( d iv) kg/cm 2 kg/cm 2 %
0 0 0
0.025 16.2 1 12.8 1 10.2 1
0.050 43.2 2 33.1 2 22.8 1
0.075 75.6 4 61.3 3 46.2 2
0.100 70.3 123.2 6 9.6 13.6 96.2 5 4.68 6.7 71.6 4 4.36 6.2
0.150 185.1 9 133.4 7 105.9 5
0.200 105.5 264.3 13 23.6 22.3 170.3 9 11.65 11.0 146.5 7 10.92 10.4
0.250 397.1 20 256.8 13 212.4 11
0.300 653.2 33 406.2 21 324.5 16
0.400 872.1 44 523.5 27 471.3 24
0.500 861.8 44 657.4 33 534.0 27

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

LABORATORIO MECANICA DE SUELOS CONCRETOS Y PAVIMENTOS


RELACION DE SOPORTE DE CALIFORNIA (C.B.R.)
(NORMA MTC E-132, AASHTO T-193, ASTM D 1883)
SOLICITANTE : DISTRIBUIDORA NORTE PACASMAYO SRL

PROYECTO : INGº RESP.

MUESTRA : SUBRASANTE - MUESTRA 01 FECHA : 09/04/2019


CANTERA : HECHO POR

PRODUCCION : DEL KM
UBICACIÓN : CALLES -HUAMACHUCO AL KM

GRAFICO DE PENETRACION DE CBR

2.18 Generar gráfico


2.15
2.12
RESULTADOS:
2.09
C.B.R. AL 100% DE M.D.S. (%) 0.1": 13.6 0.2": 22.3
2.06
C.B.R. AL 95% DE M.D.S. (%) 0.1": 5.5 0.2": 8.4
Densidad Seca (gr/cc)

2.03
C.B.R. AL 90% DE M.D.S. (%) 0.1": 6.2 0.2": 10.3
2.00
1.97
1.94 Datos del Proctor
1.91 Densidad Seca 2.065 gr/cc 1.962149
1.88 Optimo Humedad 9.24 %
1.85
1.82
OBSERVACIONES:
1.79
1.76
0 20 40 60 80
CBR (%)
X 5.5 13.6
CBR 0.1" CBR 0.2"
95%MDS 100%MDS Limite superior
Y 1.96 1.96 2.065 2.065
6.2
EC = 56 GOLPES EC = 25 GOLPES EC = 12 GOLPES

y = -921.61x 3 + 671.45x 2 - 15.766x y = -233.77x 3 + 213.49x 2 + 18.737x 1.86 1.86 y = -297.59x 3 + 249.38x 2 + 4.8934x
100.0 100.0 100.0

90.0 90.0 90.0

80.0 80.0 80.0

70.0 70.0 70.0


CARGA (Kg/cm2)

60.0 60.0 60.0

50.0 50.0 50.0

40.0 40.0
40.0
22.3 %
30.0 30.0
30.0

20.0 20.0
13.6 % 11 % 20.0
10.4 %
10.0
10.0
6.7 % 10.0 6.2 %

0.0
0.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6
0.0 0.1 0.2 0.3 0.4 0.5 0.6
PENETRACION (Pulg) PENETRACION (Pulg)
6.120864281 PENETRACION (Pulg)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

PROCTOR Y CBR MUESTRA N° 2

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

ENSAYO PROCTOR MODIFICADO


MTC E 115 - ASTM D 1557 - AASHTO T-180 D

SOLICITANTE : DISTRIBUIDORA NORTE PACASMAYO SRL :


PROYECTO : INGº RESP. :
MUESTRA : SUBRASANTE - MUESTRA 02 FECHA : 09/04/2019
CANTERA : HECHO POR :
PRODUCCION : DEL KM :
UBICACIÓN : CALLES - HUAMACHUCO AL KM :
COMPACTACIÓN
MÉTODO DE COMPACTACIÓN : "B"
NUMERO DE GOLPES POR CAPA : 25
NUMERO DE CAPAS : 5
NÚMERO DE ENSAYO 1 2 3 4
PESO (SUELO + MOLDE) (gr) 6130 6291 6329 6238
PESO DE MOLDE (gr) 4177 4177 4177 4177
PESO SUELO HÚMEDO (gr) 1953 2114 2152 2061
VOLUMEN DEL MOLDE (cm 3) 948 948 948 948
DENSIDAD HÚMEDA (gr/cm 3) 2.060 2.230 2.270 2.174
DENSIDAD SECA (gr/cm 3) 1.954 2.065 2.082 1.948
CONTENIDO DE HUMEDAD
RECIPIENTE Nº s/n s/n s/n s/n
PESO (SUELO HÚMEDO + TARA) (gr) 112.98 91.28 105.85 95.71
PESO (SUELO SECO + TARA) (gr) 107.82 85.49 98.13 87.06
PESO DE LA TARA (gr) 12.60 13.15 12.68 12.54
PESO DE AGUA (gr) 5.16 5.79 7.72 8.65
PESO DE SUELO SECO (gr) 95.22 72.34 85.45 74.52
CONTENIDO DE HUMEDAD (%) 5.42 8.00 9.03 11.61
MÁXIMA DENSIDAD SECA (gr/cm 3) 2.082 ÓPTIMO CONTENIDO DE HUMEDAD (%) 9.07

CURVA DE COMPACTACIÓN Generar Gráfico

2.180

2.100
DENSIDAD SECA (gr/cm3)

2.020

1.940

1.860

1.780

1.700
4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0

CONTENIDO DE HUMEDAD (%)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
LABORATORIO MECANICA DE SUELOS CONCRETOS Y PAVIMENTOS
RELACION DE SOPORTE DE CALIFORNIA (C.B.R.)
(NORMA MTC E-132, AASHTO T-193, ASTM D 1883)
SOLICITANTE DISTRIBUIDORA NORTE PACASMAYO SRL :
PROYECTO INGº RESP. :
MUESTRA SUBRASANTE - MUESTRA 02 FECHA : 09/04/2019

CANTERA HECHO POR


:
PRODUCCION DEL KM :
UBICACIÓN CALLES - HUAMACHUCO AL KM :
DATOS DEL PROCTOR
MAXIMA DENSIDAD SECA : 2.082 g/cm3 CAPACIDAD : 10000 Lbs.
OPTIMO CONTENIDO DE HUMEDAD : 9.07 % ANILLO : 1

ENSAYO DE CBR
MTC E 132 - ASTM D 1883 - AASHTO T-193
Molde Nº 4 8 11
Nº Capa 5 5 5
Golpes por capa Nº 56 25 12
Cond. de la muestra NO SATURADO SATURADO NO SATURADO SATURADO NO SATURADO SATURADO

Peso molde + suelo húmedo (gr) 13142 11632 13026 11539 12776 11864
Peso de molde (gr) 8332 8332 8472 8472 8470 8470
Peso del suelo húmedo (gr) 4810 3300 4554 3067 4306 3394
Volumen del molde (cm3) 2102 2102 2102 2102 2104 2104
Densidad húmeda (gr/cm3) 2.288 1.570 2.167 1.459 2.047 1.613
Humedad (%) 9.84 16.08 9.61 16.12 9.21 16.19
Densidad seca (gr/cm3) 2.083 1.353 1.977 1.256 1.874 1.388
Tarro Nº S/N 65 S/N 67 S/N 69
Tarro + Suelo húmedo (gr) 113.89 1161.00 116.45 1073.10 121.61 1063.10
Tarro + Suelo seco (gr) 104.86 1043.00 107.62 967.00 112.47 958.00
Peso del Agua (gr) 9.03 118.00 8.83 106.10 9.14 105.10
Peso del tarro (gr) 13.09 309.00 15.72 309.00 13.22 309.00
Peso del suelo seco (gr) 91.77 734.00 91.90 658.00 99.25 649.00
Humedad (%) 9.84 16.08 9.61 16.12 9.21 16.19
Promedio de Humedad (%) 9.84 16.08 9.61 16.12 9.21 16.19

EXPANSION
TIEMPO EXPANSION EXPANSION EXPANSION
FECHA HORA DIAL DIAL DIAL
Hr. mm % mm % mm %
24/03/2019 16:00
25/03/2019 16:00 24
26/03/2019 16:00 48 0.03 0.0 0.0 0.09 0.0 0.0 0.11 0.0 0.0
27/03/2019 16:00 72 0.08 0.0 0.0 0.14 0.0 0.0 0.13 0.0 0.0
28/03/2019 16:00 96 0.12 0.0 0.0 0.20 0.0 0.0 0.14 0.0 0.0

0.003 % NO PRESENTA EXPANSIÒN

PENETRACION
CARGA MOLDE Nº 4 MOLDE Nº 8 MOLDE Nº 11
PENETRACION STAND. CARGA CORRECCION CARGA CORRECCION CARGA CORRECCION
pulg kg/cm2 Dial ( d iv) kg/cm 2 kg/cm 2 % Dial ( d iv) kg/cm 2 kg/cm 2 % Dial ( d iv) kg/cm 2 kg/cm 2 %
0 0 0
0.025 36.7 2 28.4 1 18.0 1
0.050 91.2 5 55.2 3 38.6 2
0.075 204.3 10 126.3 6 81.1 4
0.100 70.3 304.2 15 14.4 20.5 231.3 12 10.82 15.4 136.4 7 7.84 11.1
0.150 407.7 21 343.7 17 238.5 12
0.200 105.5 505.2 26 24.2 22.9 424.1 22 20.86 19.8 328.0 17 17.18 16.3
0.250 562.4 29 512.8 26 433.6 22
0.300 587.2 30 562.7 29 503.9 26
0.400 670.5 34 634.0 32 588.3 30
0.500 780.0 40 682.2 35 647.5 33

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com
Demetrio Carranza Peña
INGENIERO CIVIL
C.I.P. N° 191809

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

LABORATORIO MECANICA DE SUELOS CONCRETOS Y PAVIMENTOS


RELACION DE SOPORTE DE CALIFORNIA (C.B.R.)
(NORMA MTC E-132, AASHTO T-193, ASTM D 1883)
SOLICITANTE : DISTRIBUIDORA NORTE PACASMAYO SRL

PROYECTO : INGº RESP.

MUESTRA : SUBRASANTE - MUESTRA 02 FECHA : 09/04/2019


CANTERA : HECHO POR

PRODUCCION : DEL KM
UBICACIÓN : CALLES - HUAMACHUCO AL KM

GRAFICO DE PENETRACION DE CBR

2.16 Generar gráfico


2.13
RESULTADOS:
2.10
C.B.R. AL 100% DE M.D.S. (%) 0.1": 20.5 0.2": 22.9
2.07 C.B.R. AL 95% DE M.D.S. (%) 0.1": 14.3 0.2": 17.2
Densidad Seca (gr/cc)

2.04 C.B.R. AL 90% DE M.D.S. (%) 0.1": 11.1 0.2": 16.3

2.01
Datos del Proctor
1.98
Densidad Seca 2.082 gr/cc 1.977945
1.95
Optimo Humedad 9.07 %
1.92

1.89 OBSERVACIONES:
1.86
0 20 40 60 80
CBR (%)
X 14.3 20.5
CBR 0.1" CBR 0.2"
95%MDS 100%MDS Limite superior
Y 1.98 1.98 2.082 2.082
11.1
EC = 56 GOLPES EC = 25 GOLPES EC = 12 GOLPES

y = 214.51x 3 - 293.13x 2 + 171.01x y = -203.25x 3 + 21.428x 2 + 108.13x 1.87 1.87 y = -416.51x 3 + 234.66x 2 + 51.401x
100.0 100.0 100.0

90.0 90.0 90.0

80.0 80.0 80.0

70.0 70.0 70.0


CARGA (Kg/cm2)

60.0 60.0 60.0

50.0 50.0 50.0

40.0 40.0
40.0
22.9 %
30.0 30.0
19.8 % 30.0

20.0 20.5 % 16.3 %


20.0
20.0
15.4 %
10.0 11.1 %
10.0
10.0

0.0
0.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6
0.0 0.1 0.2 0.3 0.4 0.5 0.6
PENETRACION (Pulg) PENETRACION (Pulg)
6.120864281 PENETRACION (Pulg)

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ofi. Urb. Monserrate – Av. Santa Teresa de Jesús MZ E2 L. 09 - Trujillo - Telf. 044-279102 - 949908409
Resolución N° 5527-2019/DSD-INDECOPI Email. Geocons.srl@gmail.com; http://www.geoconsperu.com

Você também pode gostar