AD00.19-N-9039GA Fault code list for front module (FM) control unit 11.1.

08
MODEL 930, 932, 933, 934

Fault code Fault code description


0109 Internal error in control unit FM front module
010A Internal error in control unit FM front module
0201 Overvoltage at terminal 30
0202 Undervoltage at terminal 30
0203 Circuit 30 has failed.
033C Failure of the frame CAN bus(GM-FM)
033D Communication problem on the frame CAN bus(GM-FM)
0346 Communication fault with control unit BS Brake control
0347 Communication fault with control unit BS Brake control
034A Communication fault with control unit FR drive control
0352 Communication fault with control unit INS Instrument
0355 Communication fault with control unit MTCO Modular tachograph
0357 Communication fault with control unit GM Base module
0358 Communication fault with control unit GM Base module
0359 Communication fault with control unit GM Base module
035B Communication fault with control unit MSF Modular switch panel (switch module 4 'Master')
035C Communication fault with control unit MSF Modular switch panel (switch module 4 'Master')
0365 No CAN message 'Vehicle speed' from control module FR drive control or message is faulty.
0366 No CAN message 'Engine speed' from control module FR drive control or message is faulty.
0371 No CAN message 'System and (or) update time' from control module GM Base module or message is faulty.
0373 No CAN message 'Failure of the frame CAN bus' from control module GM Base module or message is faulty.
037E No CAN message 'Current time' from control module MTCO Modular tachograph or message is faulty.
037F No CAN message 'Current date' from control module MTCO Modular tachograph or message is faulty.
0381 No CAN message 'Generator signal (D+)' from control module GM Base module or message is faulty.
0383 The CAN message 'Request of inter-axle lock' from control unit MSF modular switch panel (switch module 4 'Master') is
missing or faulty.
0384 The CAN message 'Front axle inter-wheel differential lock request' from control unit MSF modular switch panel (switch
module 4 'Master') is missing or faulty.
0385 The CAN message 'Rear axle inter-wheel differential lock request' from control unit MSF modular switch panel (switch
module 4 'Master') is missing or faulty.
0386 The CAN message 'Transfer case position request' from control unit MSF modular switch panel (switch module 4 'Master')
is missing or faulty.
0388 The CAN message 'Specified value of headlamp range adjustment' from control unit MSF modular switch panel (switch
module 4 'Master') is missing or faulty.
03E6 Implausible wake-up signal on the frame CAN bus(GM-FM)
043C Failure of the frame CAN bus(FM-HM)
043D Communication problem on the frame CAN bus(FM-HM)
045E Communication fault with control unit HM Rear module(FM-HM)
045F Communication fault with control unit HM Rear module(FM-HM)
0475 No CAN message 'Failure of the frame CAN bus' from control module HM Rear module or message is faulty.
048A The CAN message 'Specified current of shock absorbers on front axle' from control unit HM Rear module is missing or
faulty.
048B The CAN message 'Interaxle differential lock at rear axle' from control unit HM Rear module is missing or faulty.
048C The CAN message 'Interwheel differential lock at rear axle 1' from control unit HM Rear module is missing or faulty.
048D The CAN message 'Interwheel differential lock at rear axle 2' from control unit HM Rear module is missing or faulty.
048E The CAN message 'Interaxle differential lock at transfer case' from control unit HM Rear module is missing or faulty.
0615 Wake-up signal of frame CAN bus has Short circuit to ground.(FM-HM)
06E6 Implausible wake-up signal on the frame CAN bus(FM-HM)
0719 Emergency power supply by the base module is active.
0F0F Internal error in control unit FM front module
0F10 Internal error in control unit FM front module
1432 The ground line of the position sensor for front axle level control has Open circuit.
1433 The ground line of the position sensor for front axle level control has Short circuit to ground.
1434 The ground line of the position sensor for front axle level control has Short circuit to positive.
1532 Position sensor for front axle level control has Open circuit.
1533 Position sensor for front axle level control has Short circuit to ground.
1534 Position sensor for front axle level control has Short circuit to positive.
1535 The coil resistance of the position sensor at the front axle is outside the permissible range.
2C0F Internal error in control unit FM front module
2C10 Roll control parameters contain invalid values.
321E Common ground line for the proportioning valves in the shock absorbers of the front axle has Open circuit.
321F Common ground line for the proportioning valves in the shock absorbers of the front axle has Short circuit to ground.
3220 Common ground line for the proportioning valves in the shock absorbers of the front axle has Short circuit to positive.
331E Proportioning valves in the shock absorbers on the front axle have Open circuit.
© Daimler AG, 10/25/11, G/09/11, ad00.19-n-9039ga, Fault code list for front module (FM) control unit Page 1 of 4
MODEL 930, 932, 933, 934
331F Proportioning valves in the shock absorbers on the front axle have Short circuit to ground.
3320 Proportioning valves in the shock absorbers on the front axle have Short circuit to positive.
3321 The specified current for the proportioning valves in the shock absorbers on the front axle not reached.
370F Internal error in control unit FM front module
3710 Internal error in control unit FM front module
3C1E Common supply line of differential lock indicator switches has Open circuit.
3C1F Common supply line of differential lock indicator switches has Short circuit to ground.
3C20 Common supply line of differential lock indicator switches has Short circuit to positive.
3D28 Indicator switch 'Interwheel differential lock' at front axle 1 has Short circuit to ground
3D29 Indicator switch 'Interwheel differential lock' at front axle 1 has Short circuit to positive
3E28 Indicator switch 'Interwheel differential lock' at front axle 2 has Short circuit to ground
3E29 Indicator switch 'Interwheel differential lock' at front axle 2 has Short circuit to positive
3F28 Indicator switch 'Interaxle differential lock' at front axle has Short circuit to ground
3F29 Indicator switch 'Interaxle differential lock' at front axle has Short circuit to positive
42D2 Plausibility error when engaging interwheel differential lock at rear axle 1
42D3 Plausibility error when disengaging interwheel differential lock at rear axle 1
43D2 Plausibility error when engaging interwheel differential lock at rear axle 2
43D3 Plausibility error when disengaging interwheel differential lock at rear axle 2
44D2 Plausibility error when engaging interwheel differential lock at front axle 1
44D3 Plausibility error when disengaging interwheel differential lock at front axle 1
45D2 Plausibility error when engaging interwheel differential lock at front axle 2
45D3 Plausibility error when disengaging interwheel differential lock at front axle 2
46D2 Plausibility error when engaging interaxle differential lock at rear axle
46D3 Plausibility error when disengaging interaxle differential lock at rear axle
47D2 Plausibility error when engaging interaxle differential lock at front axle
47D3 Plausibility error when disengaging interaxle differential lock at front axle
48D2 Plausibility error when engaging interaxle differential lock at transfer case
48D3 Plausibility error when disengaging interaxle differential lock at transfer case
490F Internal error in control unit FM front module
4910 Differential lock parameters contain invalid values.
4B1E Common ground line for the differential lock solenoid valves has Open circuit.
4B1F Common ground line for the differential lock solenoid valves has Short circuit to ground.
4B20 Common ground line for the differential lock solenoid valves has Short circuit to positive.
4C1E Solenoid valve 'Interwheel differential lock at rear axle' has Open circuit.
4C1F Solenoid valve 'Interwheel differential lock at rear axle' has Short circuit to ground.
4C20 Solenoid valve 'Interwheel differential lock at rear axle' has Short circuit to positive.
4D1E Common ground line of solenoid valves has Open circuit.
4D1F Common ground line of solenoid valves has Short circuit to ground.
4D20 Common ground line of solenoid valves has Short circuit to positive.
4E1E Solenoid valve 'Interwheel differential lock at front axle' has Open circuit.
4E1F Solenoid valve 'Interwheel differential lock at front axle' has Short circuit to ground.
4E20 Solenoid valve 'Interwheel differential lock at front axle' has Short circuit to positive.
4F1E 'Inter-axle lock' solenoid valve has Open circuit.
4F1F 'Inter-axle lock' solenoid valve has Short circuit to ground.
4F20 'Inter-axle lock' solenoid valve has Short circuit to positive.
501E Common supply line for the brake wear sensors at front axle 1 has Open circuit.
501F Common supply line for the brake wear sensors at front axle 1 has Short circuit to ground.
5020 Common supply line for the brake wear sensors at front axle 1 has Short circuit to positive.
5132 Brake wear sensor at front axle 1, left, has Open circuit.
5133 Brake wear sensor at front axle 1, left, has Open circuit or Short circuit to ground.
5134 Brake wear sensor at front axle 1, left, has Short circuit to positive.
5136 Brake wear sensor at front axle 1, left, has exceeded the measurement range.
5137 Brake wear sensor at front axle 1, left, has fallen below measurement range.
5232 Brake wear sensor at front axle 1, right, has Open circuit.
5233 Brake wear sensor at front axle 1, right, has Open circuit or Short circuit to ground.
5234 Brake wear sensor at front axle 1, right, has Short circuit to positive.
5236 Brake wear sensor at front axle 1, right, has exceeded the measurement range.
5237 Brake wear sensor at front axle 1, right, has fallen below the measurement range.
551E Common supply line for the brake wear sensors at front axle 2 has Open circuit.
551F Common supply line for the brake wear sensors at front axle 2 has Short circuit to ground.
5520 Common supply line for the brake wear sensors at front axle 2 has Short circuit to positive.
5632 Brake wear sensor at front axle 2, left, has Open circuit.
5633 Brake wear sensor at front axle 2, left, has Open circuit or Short circuit to ground.
5634 Brake wear sensor at front axle 2, left, has Short circuit to positive.
5636 Brake wear sensor at front axle 2, left, has exceeded the measurement range.
5637 Brake wear sensor at front axle 2, left, has fallen below measurement range.
5732 Brake wear sensor at front axle 2, right, has Open circuit.
5733 Brake wear sensor at front axle 2, right, has Open circuit or Short circuit to ground.
5734 Brake wear sensor at front axle 2, right, has Short circuit to positive.
© Daimler AG, 10/25/11, G/09/11, ad00.19-n-9039ga, Fault code list for front module (FM) control unit Page 2 of 4
MODEL 930, 932, 933, 934
5736 Brake wear sensor at front axle 2, right, has exceeded the measurement range.
5737 Brake wear sensor at front axle 2, right, has fallen below the measurement range.
590F Internal error in control unit FM front module
5910 Brake wear sensor parameters contain invalid values.
5F32 Oil temperature sensor of maintenance system at front axle has Open circuit.
5F33 Oil temperature sensor of maintenance system at front axle has Short circuit to ground.
5F34 Oil temperature sensor of maintenance system at front axle has Short circuit to positive.
5F36 Oil temperature sensor of maintenance system at front axle has exceeded the measurement range.
5F37 Oil temperature sensor of maintenance system at front axle has fallen below the measurement range.
630F Internal error in control unit FM front module
6310 Maintenance system parameters contain invalid values.
641E Left front turn signal lamp has Open circuit.
641F Left front turn signal lamp has Short circuit to ground.
6420 Left front turn signal lamp has Short circuit to positive.
651E Right front turn signal lamp has Open circuit.
651F Right front turn signal lamp has Short circuit to ground.
6520 Right front turn signal lamp has Short circuit to positive.
661E Left side turn signal lamp has Open circuit.
661F Left side turn signal lamp has Short circuit to ground.
6620 Left side turn signal lamp has Short circuit to positive.
671E Right side turn signal lamp has Open circuit.
671F Right side turn signal lamp has Short circuit to ground.
6720 Right side turn signal lamp has Short circuit to positive.
681E Left front end-outline marker lamp has Open circuit.
681F Left front end-outline marker lamp has Short circuit to ground.
6820 Left front end-outline marker lamp has Short circuit to positive.
691E Right front end-outline marker lamp has Open circuit.
691F Right front end-outline marker lamp has Short circuit to ground.
6920 Right front end-outline marker lamp has Short circuit to positive.
6A1E Left low beam lamp has Open circuit.
6A1F Left low beam lamp has Short circuit to ground.
6A20 Left low beam lamp has Short circuit to positive.
6B1E Left high beam lamp has Open circuit.
6B1F Left high beam lamp has Short circuit to ground.
6B20 Left high beam lamp has Short circuit to positive.
6C1E Left front standing lamp has Open circuit.
6C1F Left front standing lamp has Short circuit to ground.
6C20 Left front standing lamp has Short circuit to positive.
6D1E Supply line of left and right headlamp range adjustment has Open circuit.
6D1F Supply line of left or right headlamp range adjustment has Short circuit to ground.
6D20 Supply line of left or right headlamp range adjustment has Short circuit to positive.
6E1E Left front headlamp range adjustment has Open circuit.
6E1F Control voltage of left or right headlamp range adjustment has Short circuit to ground.
6E20 Control voltage of left or right headlamp range adjustment has Short circuit to positive.
6F1E Right low beam lamp has Open circuit.
6F1F Right low beam lamp has Short circuit to ground.
6F20 Right low beam lamp has Short circuit to positive.
701E Right high beam lamp has Open circuit.
701F Right high beam lamp has Short circuit to ground.
7020 Right high beam lamp has Short circuit to positive.
711E Right front standing lamp has Open circuit.
711F Right front standing lamp has Short circuit to ground.
7120 Right front standing lamp has Short circuit to positive.
721E Right front headlamp range adjustment has Open circuit.
721F Right front headlamp range adjustment has Short circuit to ground.
7220 Right front headlamp range adjustment has Short circuit to positive.
731E Right front headlamp range adjustment has Open circuit.
731F Right front headlamp range adjustment has Short circuit to ground.
7320 Right front headlamp range adjustment has Short circuit to positive.
761E Left fog lamp has Open circuit.
761F Left fog lamp has Short circuit to ground.
7620 Left fog lamp has Short circuit to positive.
771E Right fog lamp has Open circuit.
771F Right fog lamp has Short circuit to ground.
7720 Right fog lamp has Short circuit to positive.
781E Left side marker lamp has Open circuit.
781F Left side marker lamp has Short circuit to ground.
7820 Left side marker lamp has Short circuit to positive.
7822 At least one bulb is faulty in the left side-marker lamp.
© Daimler AG, 10/25/11, G/09/11, ad00.19-n-9039ga, Fault code list for front module (FM) control unit Page 3 of 4
MODEL 930, 932, 933, 934
791E Right side marker lamp has Open circuit.
791F Right side marker lamp has Short circuit to ground.
7920 Right side marker lamp has Short circuit to positive.
7922 At least one bulb is faulty in the right side-marker lamp.
7A1E Work lamp has Open circuit.
7A1F Work lamp has Short circuit to ground.
7A20 Work lamp has Short circuit to positive.
7B1E Left entrance lamp has Open circuit.
7B1F Left entrance lamp has Short circuit to ground.
7B20 Left entrance lamp has Short circuit to positive.
7C1E Right entrance lamp has Open circuit.
7C1F Right entrance lamp has Short circuit to ground.
7C20 Right entrance lamp has Short circuit to positive.
810F Internal error in control unit FM front module
8110 Exterior light parameters contain invalid values.
8C1E Common ground line of solenoid valves has Open circuit.
8C1F Common ground line of solenoid valves has Short circuit to ground.
8C20 Common ground line of solenoid valves has Short circuit to positive.
8D1E Solenoid valve 'Off-road gear' on transfer case has Open circuit.
8D1F Solenoid valve 'Off-road gear' on transfer case has Short circuit to ground.
8D20 Solenoid valve 'Off-road gear' on transfer case has Short circuit to positive.
8E1E Solenoid valve 'Neutral position' on transfer case has Open circuit.
8E1F Solenoid valve 'Neutral position' on transfer case has Short circuit to ground.
8E20' Solenoid valve 'Neutral position' on transfer case has Short circuit to positive.
8F0F Internal error in control unit FM front module
8F10 Transfer case parameters contain invalid values.
90D2 Plausibility error when engaging on-road gear in transfer case
90D3 Plausibility error when disengaging on-road gear in transfer case
91D2 Plausibility error when engaging neutral in transfer case
91D3 Plausibility error when disengaging neutral in transfer case
92D2 Plausibility error when engaging off-road gear in transfer case
92D3 Plausibility error when disengaging off-road gear in transfer case
9B1E The pulsed voltage supply of the pressure switch 'Steering oil level switch' has Open circuit.
9B1F The pulsed voltage supply of the pressure switch 'Steering oil level switch' has Short circuit to ground.
9B20 The pulsed voltage supply of the pressure switch 'Steering oil level switch' has Short circuit to positive.
9C28 Steering oil level switch has Short circuit to ground.
9C29 Steering oil level switch has Short circuit to positive.
9D1E The pulsed voltage supply of the pressure switch 'Power steering' has Open circuit.
9D1F The pulsed voltage supply of the pressure switch 'Power steering' has Short circuit to ground.
9D20 The pulsed voltage supply of the pressure switch 'Power steering' has Short circuit to positive.
9E28 Pressure switch 'Power steering' has Short circuit to ground.
9E29 Pressure switch 'Power steering' has Short circuit to positive.
9F0F Internal error in control unit FM front module
9F10 Steering parameters contain invalid values.
A532 Outside air temperature sensor has Open circuit
A533 Outside air temperature sensor has Short circuit to ground
A534 Outside air temperature sensor has Open circuit, Short circuit to positive
A536 Outside air temperature sensor has exceeded the measurement range.
A537 Outside air temperature sensor has fallen below the measurement range.
A90F Internal error in control unit FM front module
A910 Outside air temperature sensor parameters contain invalid values.
AA1E Ground line of signaling horn has Open circuit.
AA1F Ground line of signaling horn has Short circuit to ground.
AA20 Ground line of signaling horn has Short circuit to positive.
AB1E Signaling horn has Open circuit.
AB1F Signaling horn has Short circuit to ground.
AB20 Signaling horn has Short circuit to positive.
AE0F Internal error in control unit FM front module
AE10 Signaling horn parameters contain invalid values.