Você está na página 1de 2

P/2016/00474

NOTES
100

1. Do not scale. All dimensions are in millimetres unless


shown otherwise.
Received 24.03.2016 2. This drawing is to be in conjunction with all other
relevant contract drawings
MH1
3. The contractor should site check all existing
dimensions as shown. Any discrepancies on this
drawing identified by the contractor should be brought
MH2 to the attention of the engineer prior to construction
on site.
MH4 4. The contractor shall conform to all statutory authority
requirements, checking with the employer/clent to
identify both below ground and overhead services.
50

Contractor to fully comply with all CDM, H&S and


party wall acts that are current. All BS references are
40

to current editions.
5. All temporary works for formwork, excavations etc., to
be the design responsibility of the contractor.
30

6. All levels are in metres (A.O.D)


7. Drawing based on information provided by
20

Staffordshire County Council, Base Design


16-02-16_2DMX, Amey Survey 04.01.16 2D MX
8. SuDS features designed in accordance with BRE
10

Digest 365 based on Infiltration rates surveyed


07.01.16 by CC Ground Investigation Ltd
0

9. Refer to following scheme drawings for drainage


information
A1

MH5 CDX8620/R05/01 General Arrangement


CDX8620/R05/04-08 Manhole Schedules
CDX8620/R05/09-10 Construction Details
CDX8620/R05/11 Pond Details
CDX8620/R05/12 Soakaway Details

Soakaway
DRAINAGE NOTES
MH6 MH7 1. All drainage works shall be carried out in accordance
Outfall with the contract specification
2. The contractor shall allow for keeping sewer trenches
and excavations as dry as practicable by pumping from
temporary sumps, dewatering and well pointing as
appropriate. The point and method of discharge to be
agreed with the drainage authority.
3. Manholes and inspection covers and frames shall
comply with the relevant provisions of BS EN124.
Manhole covers and frames to be a non-rocking design
Datum
with cushion inserts and kitemarked.
46.000mAOD
4. Manhole covers potentially subject to vehicular loads to

48.315 49.440

46.740 47.940

46.689 47.900

46.549 47.807
54.260

51.590 53.540

51.115 53.040
Cover have cover grade D400 all other covers to be B124
Level grade.
5. Contractor to take measures to protect operatives with
respect to the presence of gas in the sewer trenches

47.440

46.740

46.689

46.549
51.590

51.115
52.835

Invert
and manholes through the use of gas monitoring
Level
equipment and breathing apparatus as required.
6. Formation level for manhole bases and pipe trenches
12.31m PE Pipe
78.93m PE Pipe ref: 1.000 30.34m PE Pipe ref: 1.001 69.00m PE Pipe ref: 1.002 41.73m PE Pipe ref:1.003 ref: 1.004
36.36m PE Pipe ref: 1.005 to be free from soft spots, blinding concrete and/or
Pipe 225mm @ 1/63.4 225mm @ 1/63.9 225mm @ 1/24.6 300mm @ 1/59.6 300mm @
300mm @ 1/259.7
stone may be used as determines on site
Bedding Class S
Details Bedding Class S Bedding Class S Bedding Class S Bedding Class S 1/244.0
Combined Filter/ Carrier drain 7. Where significant excavation is required below the
Bedding Class S
manhole base/drainage trench formation level, due to
poor ground conditions, suitable excavated material,

47.881
51.171

47.826 49.892

47.827 49.358

47.819 48.887

47.814 48.483

47.814 48.173

220.00 47.828 47.942

47.834 48.106

250.00 47.836 47.855

260.00 47.827 47.829

268.72 47.819 47.807


49.720 53.015

48.696 52.578

48.040 51.703

47.862 51.130

47.826 50.505
Proposed
54.261

54.122 54.177

53.941 54.029

53.727 53.940

53.444 53.833

53.303 53.734

52.924 53.647

52.505 53.585

52.074 53.515

50.137 53.220

49.918 52.995
Ground gravel rejects or graded hardcore may be used as
Level backfill to formation level. Fill material is to be
compacted in layers with a vibratory roller complying

48.116

240.00 47.836
Existing
54.240

with method 2 of table 6 / 4, specification for highway


Ground
Trim to this line for A1

works. It is the responsibility of the contractor to


Level provide a suitable formation for manhole bases and
pipe trenches.

200.00

210.00

230.00
110.00

120.00

130.00

140.00

150.00

160.00

170.00

180.00

190.00
100.00
20.00

40.00
30.00

50.00

60.00

70.00

80.00

90.00
10.00
0.00

Chainage 8. Geotextile fabric to be wrapped around pipe granular


bedding where trenches are formed in running
sand/silty materials where there is a risk of fines
ingress - geotextile also to extend under manhole base.
Long Section MH1 - Soakway
Scale 1:500(H) 1:50(V)
MH8

MH9
MH3 MH4

Original Version Preliminary


For target cost
Drawn: RJP For tender
Design: RJP For construction
MH12 As constructed
P:\COSTCDX8605 - Branston Locks\07 Design Disciplines\AutoCAD\Work Area\500 Series\CDX8620-R05-02-03 Long Sections.dwg

Date: 02/03/16 Other


MH11 MH13
Checked by:-
Pond
S R Morgan
54.240

Inlet 1

Approved by:- (Drawing NOT approved if this box is empty)


Digitally signed by Sean Geraghty
Date: 2016.03.03 12:03:02 Z

Datum48.000mAOD Datum45.000mAOD

47.571
48.020

48.600

47.560
52.960

53.040

50.180
54.260

Cover Cover
Level Level www.staffordshire.gov.uk www.amey.co.uk
48.680

46.520
46.135

46.108
46.108

45.929
45.929
45.913
51.395

51.115
51.115

50.115

48.755
54.261

Invert Invert Project Name


Level Level
Branston Locks
9.18m PE Pipe 5.00m PE Pipe
30.53m PE Pipe ref: 2.000 45.67m PE Pipe ref: 5.000 67.04m PE Pipe ref: 5.001 ref: 5.002 72.67m PE Pipe ref: 5.003 ref: 5.004
Pipe 225mm @ 1/72.7
Pipe 225mm @ 1/33.6 300mm @ 1/31.0 375mm @ 1/406.0
375mm @ 375mm @
Details Bedding Class S Details Bedding Class S Bedding Class S 1/328.0 Bedding Class S 1/328
BC S BCS

Proposed Proposed Drawing Title

49.441

49.451
47.741 48.942
48.877 52.872

47.672 49.635

47.703 49.279

47.764 48.618

47.768 48.327

110.00 47.662 48.098

120.00 47.662 48.400

130.00 47.795 48.838

140.00 47.839 49.133

160.00 47.765 49.766

200.00 47.494 46.409


48.833 52.965

49.003 52.847

49.732 53.036

47.581 51.542

47.556 51.208

47.532 50.895

47.575 50.598

47.689 50.326

47.695 50.016

170.00 47.731 50.097

180.00 47.660 50.137


Ground Ground Drainage
Level Level
Existing Existing Long Sections (1 of 2)
150.00 47.803

190.00 47.590
Ground Ground
Level Level
100.00
20.00

20.00

40.00
30.00

30.00

50.00

60.00

70.00

80.00

90.00
10.00

10.00
0.00

0.00

Chainage Chainage
Grid reference :
Original Drawing Size : A1 Dimensions : -
02

Long Section MH3 - MH4 Long Section MH8 - Pond Inlet 1 Scale : As Shown Copyright c Amey

Scale 1:500(H) 1:50(V) Scale 1:500(H) 1:50(V) Drawing No Rev

. CDX8620-R05-02 P0
NOTES
100

1. Do not scale. All dimensions are in millimetres unless


shown otherwise.
2. This drawing is to be in conjunction with all other
relevant contract drawings
3. The contractor should site check all existing
dimensions as shown. Any discrepancies on this
drawing identified by the contractor should be brought
to the attention of the engineer prior to construction
on site.
4. The contractor shall conform to all statutory authority
requirements, checking with the employer/clent to
identify both below ground and overhead services.
50

Contractor to fully comply with all CDM, H&S and


party wall acts that are current. All BS references are
40

to current editions.
5. All temporary works for formwork, excavations etc., to
be the design responsibility of the contractor.
30

6. All levels are in metres (A.O.D)


7. Drawing based on information provided by
20

Staffordshire County Council, Base Design


16-02-16_2DMX, Amey Survey 04.01.16 2D MX
8. SuDS features designed in accordance with BRE
10

Digest 365 based on Infiltration rates surveyed


07.01.16 by CC Ground Investigation Ltd
0

9. Refer to following scheme drawings for drainage


information
A1

CDX8620/R05/01 General Arrangement


CDX8620/R05/04-08 Manhole Schedules
CDX8620/R05/09-10 Construction Details
CDX8620/R05/11 Pond Details
CDX8620/R05/12 Soakaway Details

DRAINAGE NOTES
1. All drainage works shall be carried out in accordance
with the contract specification
2. The contractor shall allow for keeping sewer trenches
and excavations as dry as practicable by pumping from
temporary sumps, dewatering and well pointing as
appropriate. The point and method of discharge to be
agreed with the drainage authority.
MH18 MH18 3. Manholes and inspection covers and frames shall
MH17 comply with the relevant provisions of BS EN124.
Manhole covers and frames to be a non-rocking design
with cushion inserts and kitemarked.
4. Manhole covers potentially subject to vehicular loads to
have cover grade D400 all other covers to be B124
MH15 MH16 grade.
5. Contractor to take measures to protect operatives with
MH11 respect to the presence of gas in the sewer trenches
Pond and manholes through the use of gas monitoring
MH14 equipment and breathing apparatus as required.
Inlet 2
MH10 6. Formation level for manhole bases and pipe trenches
to be free from soft spots, blinding concrete and/or
stone may be used as determines on site
7. Where significant excavation is required below the
Inlet from manhole base/drainage trench formation level, due to
filter drain poor ground conditions, suitable excavated material,
gravel rejects or graded hardcore may be used as
backfill to formation level. Fill material is to be
compacted in layers with a vibratory roller complying
with method 2 of table 6 / 4, specification for highway
Trim to this line for A1

works. It is the responsibility of the contractor to


provide a suitable formation for manhole bases and
pipe trenches.
Datum45.000mAOD Datum45.000mAOD Datum45.000mAOD 8. Geotextile fabric to be wrapped around pipe granular
47.480

48.020

47.680

48.540

49.760

47.570

48.460

49.480

49.760
Cover Cover Cover bedding where trenches are formed in running
Level Level Level sand/silty materials where there is a risk of fines
ingress - geotextile also to extend under manhole base.
46.505

46.285
46.135

46.555

46.372
46.372

46.018
46.018

45.930

46.827
46.827

46.773
46.018
47.035
Invert Invert Invert
Level Level Level

14.93m PE Pipe 8.81m PE Pipe


37.08m PE Pipe ref: 6.000 30.89m PE Pipe ref: 3.000 59.75m PE Pipe ref: 3.001 31.15m PE Pipe ref: 4.000
Pipe 225mm @ 1/169
Pipe 225mm @ 1/169 225mm @ 1/169
ref: 3.002 Pipe 225mm @ 1/149.5
ref: 4.001
Details Details 225mm @ 1/169 Details 225mm @ 1/150
Bedding Class Z Bedding Class Z Bedding Class S Bedding Class S
Bedding Class S Bedding Class S

Proposed Proposed Proposed

49.761
47.774 48.476

47.860 48.763

47.761 49.124

47.666 49.475
47.417 47.552

47.514 47.782
47.445 47.480

47.407 47.624

47.623 48.020

47.657 47.680

47.664 47.866

47.683 48.147

47.676 48.513

47.671 48.896

47.707 49.265

47.745 49.607

47.662 49.787

100.00 47.567 47.574

47.552 46.197
47.749 50.033

47.755 50.142
Ground Ground Ground
Level Level Level
Original Version Preliminary
Existing Existing Existing

47.656
Ground Ground Ground For target cost
Level Level Level Drawn: RJP For tender
Design: RJP For construction
47.08

40.00
20.00

30.00

20.00

20.00

40.00
30.00

50.00

60.00

70.00

80.00

90.00

30.00
10.00

10.00

10.00
0.00

0.00

0.00
Chainage Chainage Chainage As constructed
P:\COSTCDX8605 - Branston Locks\07 Design Disciplines\AutoCAD\Work Area\500 Series\CDX8620-R05-02-03 Long Sections.dwg

Date: 02/03/16 Other

Long Section MH10 - MH11 Long Section MH14 - Pond Inlet 2 Long Section MH16 - MH18 Checked by:-

Scale 1:500(H) 1:50(V) Scale 1:500(H) 1:50(V) Scale 1:500(H) 1:50(V) S R Morgan

Approved by:- (Drawing NOT approved if this box is empty)

Digitally signed by Sean Geraghty


Date: 2016.03.03 12:09:41 Z

www.staffordshire.gov.uk www.amey.co.uk

Project Name

Branston Locks

Drawing Title
Drainage
Long Sections (2 of 2)

Grid reference :
Original Drawing Size : A1 Dimensions : -
03

Scale : As Shown Copyright c Amey

Drawing No Rev

. CDX8620-R05-03 P0