Você está na página 1de 254

Internal Use Only

http://biz.lgservice.com

Multi Type Air Conditioner


SVC MANUAL(Exploded View)
MODEL
• Indoor Unit: Duct Type Room Type 4 Way CST 1 Way CST
AMNH096BTG0 AMNH076LQL0 AMNH096TEC0 AMNH096TCC0
AMNH126BTG0 AMNH096LQL0 AMNH126TEC0 AMNC096TCC0
AMNH186BTG0 AMNH096LRL0 AMNH186TEC0 AMNH126TCC0
AMNH096BPA0 AMNH126LRL0 AMNH246TFC0 AMNC126TCC0
AMNH126BPA0 AMNH186LTL0 AMNH306TFC0 AMNH09GTCC0
AMNH186BHA0 AMNH246LTL0 AMNH366TDC0 AMNH12GTCC0
AMNH246BHA0 AMNH07GD4L0 AMNH306TFA0
AMNC246BHA0 AMNH09GD4L0 AMNC306TFC0 Art Cool Deluxe Type
AMNH306BGA0 AMNH12GD4L0 AMNC366TDC0
AMNH18GD5L0 AMNH09GTEF0 AMNH076DZ*0
AMNC306BGA0 AMNH24GD5L0
AMNH366BGA0 AMNH12GTEF0 AMNH096DU*0
AMNC366BGA0 Art Cool Type AMNH18GTEF0 AMNH126DU*0
AMNH09GB1A0 AMNH24GTHF0 AMNH186D3*0
AMNH096AP*1
AMNH12GB1A0 AMNH126AP*1 AMNH246D3*0
AMNH18GB2A0 AMNH07GDZ*0
AMNH24GB2A0 CVT AMNH09GDU*0
AMNH12GDU*0
AMNH096VEA0
AMNH126VEA0 AMNH18GD3*0
AMNH186VBA0 AMNH24GD3*0
AMNH246VBA0 AMNH07GDE*0
AMNH09GDE*0
AMNH12GDE*0
• Outdoor Unit: A2UW146FA0 A2UW146FA1 A2UW146FA2
A2UW166FA0 A2UW166FA1 A2UW186FA0
A3UW186FA0 A3UW186FA1 A3UW246FA0
A4UW246FA0 A4UW24GFA0 A4UW30GFA0
A4UW306FA0 A4UW306FA1 A6UW406FA0

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Multi type Air Conditioner Service Manual

TABLE OF CONTENTS
Model Number Nomenclature ....................................................................................................................3
Symbols Used in this Manual ...................................................................................................................5
Safety Precautions......................................................................................................................................6
Dimensions................................................................................................................................................12
Indoor Unit..............................................................................................................................................12
Outdoor Unit ...........................................................................................................................................21
Product Specifications ............................................................................................................................22
Installation .................................................................................................................................................34
Select the best location of indoor unit ....................................................................................................34
How to fix ...............................................................................................................................................37
Piping and Drainage of Indoor Unit ........................................................................................................45
Connection of indoor unit piping.............................................................................................................46
Remote Controller Installation ................................................................................................................69
Connecting Pipings and the cable to Outdoor unit .................................................................................71
Checking the Drainage and Pipe forming...............................................................................................74
Maximum Length of Pipe and Extra Charge of Refrigerant Charge.......................................................79
Test Running ..........................................................................................................................................85
System Layout and Piping Length..........................................................................................................88
Installation ..............................................................................................................................................89
Installation of The Main Unit...................................................................................................................90
Connection of Piping ..............................................................................................................................91
Connection of Wiring ..............................................................................................................................92
Operation ..................................................................................................................................................93
Function of control..................................................................................................................................93
Function of Indoor Unit ...........................................................................................................................98
Function of Outdoor Unit ......................................................................................................................104
Remote Control Operation ...................................................................................................................105
Control Devices and Function ...............................................................................................................114
Simple Central Control .........................................................................................................................114
Term of Each part and Function ...........................................................................................................114
Electrical wiring ....................................................................................................................................115
Deluxe Central Control .........................................................................................................................121
Disassembly of the parts (Indoor unit) .................................................................................................127
Indoor unit ............................................................................................................................................127
Schematic Diagram.................................................................................................................................142
Electronic Control Device .....................................................................................................................142
Wiring Diagram.....................................................................................................................................154
Components Locations.........................................................................................................................160
Troubleshooting Guide ...........................................................................................................................179
Refrigeration Cycle Diagram ................................................................................................................179
Self-diagnosis Function ........................................................................................................................186
Cycle Troubleshooting Guide................................................................................................................187
Electronic Parts Troubleshooting Guide ...............................................................................................188
General Information..............................................................................................................................193
(3-way) Valve ...........................................................................................................................................209
Exploded View.........................................................................................................................................213
Indoor Unit ...........................................................................................................................................213
Outdoor Unit ........................................................................................................................................242

Copyright ©2007 LG Electronics. Inc. All right reserved. -2-


LGE Internal Use Only
Only for training and service purposes
Model Number Nomenclature

Model Number Nomenclature


Indoor Unit
AMN H 07 6 L Q A 0

Serial Number
Function
A : Basic, L : Nano Plasma + Auto Clean(Wall Mounted)
C: Plasma(Ceiling Cassette), G: Low Static Motor
ART COOL(DELUXE) Type Front Panel Color
B : Blue, D : Wood, M : Meta, R : Mirror, W : White

Chassis Name
Indoor Unit Type
L : Wall Mounted , A : ART COOL
D : ART COOL DELUXE, T : Ceiling Cassette
B : Ceiling Concealed Duct
V : Ceiling & Floor(Convertible) D : D Look (Wall Mounted)
Electrical Rating
6 : 1Ø, 220-240V, 50Hz G : 220~240V, 50/60Hz

Nominal Cooling Capacity in Btu/h


Ex) 7,000 Btu/h '07', 18,000 Btu/h '18'
Model Type
H : Heat Pump

TPS Inverter Multi System Indoor Unit

Outdoor Unit
A2U W 18 6 F A 0

Serial Number

Function
A : Basic

Multi Type
F : Free Joint Multi Type

Electrical Ratings
6 : 1Ø, 220-240V, 50Hz
8 : 3Ø, 380-415V, 50Hz
Nominal Cooling Capacity in Btu/h
Ex) 18,000 Btu/h '18', 48,000 Btu/h, 50Hz '48'

Model Type
W : DC Inverter Heat Pump

R410A TPS Inverter Multi System Outdoor Unit.


And No. of Connectable Indoor Units
Ex) A2U : Connectable max. 2 Indoor Units
A6U : Connectable max. 6 Indoor Units

Copyright ©2007 LG Electronics. Inc. All right reserved. -3-


LGE Internal Use Only
Only for training and service purposes
Model Number Nomenclature

Panel (Cassette, Built in Duct)


Category CHASSIS PANEL NAME PANEL P/NO. SERIAL NO. Remark

PT-CFA 3721A10072B 8435002992862 COOLING


PT-CFC 3721A10072G 8435002992879 COOLING + PLASMA
TF
PT-HFA 3821A10072A 8435002992886 HEATING
PT-HFC 3721A10072E 8435002992893 HEATING + PLASMA
PT-CCA 3721A10023Z 8435002994095 COOLING
PT-CCC 3721A10023W 8435002994101 COOLING + PLASMA
TC,TC1
PT-HCA 3721A10023Y 8435002994118 HEATING
PT-HCC 3721A10023V 8435002994125 HEATING + PLASMA
CST PANEL
PT-HEA 3721A10105A 8435002992978 HEATING
PT-HEC 3721A10105B 8435002992985 HEATING + PLASMA
TE(family look)
PT-CEA 3721A10105C 8435002992954 COOLING
PT-CEC 3721A10105D 8435002992961 COOLING + PLASMA
PT-HEA1 3721A10105M HEATING
TE1(family look)
PT-HEC1 3721A10105N HEATING + PLASMA
PT-HAD 3721A10106A 8435002994057 HEATING
PT-HDC 3721A10106B 8435002994064 HEATING + PLASMA
TD(family look)
PT-CDA 3721A10106C 8435002994071 COOLING
PT-CDC 3721A10106D 8435002994088 COOLING + PLASMA
PT-HDA1 3721A10106X HEATING
TH(family look)
PT-HDC1 3721A10106Z HEATING + PLASMA
BP PB-HPA 3721A20168A 9K/12K
BUILT IN DUCT
BQ PB-HQA 3721A20168B 18K/24K

P T - H E A 6. Function
1 2 3 4 5 6 Function
Basic A
Number Contents B
1, 2 Panel for Cassette Plasma Filter C
3 - D
4 Cooling/Heatpump Elevation Grille E
5 Chassis Name Elevation Grille + Plasma Filter F
6 Function TE/TB/TD Before 2003 : Basic 0
TE/TD Before 2003 : Plasma Filter 1
5. Chassis Name
Chassis Abbrevation
TC C
TB B
TD D
TE E
TF F
TH H
TJ J
BP P
BQ Q

Copyright ©2007 LG Electronics. Inc. All right reserved. -4-


LGE Internal Use Only
Only for training and service purposes
Model Number Nomenclature

Indoor Units
Model Name
Category Type Chasiss Capacity, kW(Btu/h)
2.1 2.6 3.5 5.3 7.0 8.8 10.6
(7000) (9000) (12000) (18000) (24000) (30000) (36000)
SQ AMNH AMNH - - - - -
076LQL0 096LQL0
SR - AMNH AMNH - - - -
Wall 096LRL0 126LRL0
General ST - - - AMNH AMNH - -
Mounted 186LTL0 246LTC0
AMNH AMNH AMNH
S4 07GD4L0 09GD4L0 12GD4L0
S5 AMNH AMNH
18GD5L0 24GD5L0
General SP1 - AMNN AMNN - - - -
096AP*1 126AP*1
AMNH
SZ 076DZ*0
07GDZ*0 - - - - - -
ART
Cool AMNH AMNH
Mirror SU 096DU*0 126DU*0
09GDU*0 12GDU*0 - - - -
AMNH AMNH
S3 - - - 186D3*0 246D3*0 - -
18GD3*0 24GD3*0
SE AMNH AMNH AMNH - - - -
07GDE*0 09GDE*0 12GDE*0
- AMNH/C AMNH/C
096TCC0 126TCC0 - - - -
1Way TC,TC1
AMNH09 AMNH12
GTCC0 GTCC0
TE - AMNH AMNH AMNH - - -
Ceiling 096TEC0 126TEC0 186TEC0
Cassette - AMNH AMNH AMNH - - -
4Way TE1 09GTEF0 12GTEF0 18GTEF0
TF - - - - AMNH AMNH/C -
246TFC0 306TF*0
TH - - - - AMNH - -
24GTHF0
- - - - - - AMNH/C
TD 366TDC0
- - - AMNH AMNH - -
High BH 186BHA0 246BHA0
Ceiling Static BG - - - - - AMNH/C AMNH
Concealed 306BGA0 366BGA0
BT - AMNH AMNH AMNH - - -
Duct 096BTG0 126BTG0 186BTG0
Low AMNH AMNH
Static B1 - - - - -
09GB1A0 12GB1A0
B2 - - - AMNH AMNH - -
18GB2A0 24GB2A0
Built in BP - AMNH AMNH - - - -
096BPA0 126BPA0
VE - AMNH AMNH - - - -
Ceiling & Convertible 096VEA0 126VEA0
Floor AMNH AMNH
VB - - - 186VBA0 246VBA0 - -

Outdoor Units
TPS Inverter Multi Series Multi Piping Type Distributor Type
Heat Pump Model Name A2UW146FA0/1/2 A2UW166FA0/1 A2UW186FA0 A3UW186FA0/1 A3UW246FA0 A4UW246FA0 A4UW306FA0 A4UW306FA1 A6UW406FA0 A7UW486FA0 A8UW566FA0
Rated Capacity Cooling kW(Btu/h) 4.1(14000) 4.7(16000) 5.3(18000) 5.3(18000) 7.0(24000) 7.0(24000) 8.8(30000) 8.8(30000) 11.7(40000) 14.0(48000) 16.4(56000)
Heating kW(Btu/h) 4.7(16000) 5.3(18000) 6.3(21600) 6.3(21600) 8.2(28000) 8.2(28000) 10.1(34500) 10.1(34500) 13.5(46000) 16.2(55200) 18.9(64400)
Number of Indoor Units to be Connected Max.2 Units Max.2 Units Max.2 Units Max.3 Units Max.3 Units Max.4 Units Max.4 Units Max.4 Units Max.6 Units Max.7 Units Max.8 Units
Indoor Units kW 2.1~6.2 2.1~7.0 2.1~7.0 2.1~8.8 2.1~9.7 2.1~11.4 2.1~11.4 2.1~11.4 4.7~15.2 5.6~18.3 6.6~21.3
Connectable Capacity Btu/h 7000~21000 7000~24000 7000~24000 7000~30000 7000~33000 7000~39000 7000~39000 7000~39000 16000~52000 19200~62400 22400~72800
Power Supply 1Ø, 220-240V, 50Hz
Notes : A2UW146FA0/1/2, A2UW166FA0/1, A2UW186FA0 and A3UW186FA0/1 are not TPS inverter system but one inverter compressor system.

Symbols Used in this Manual


This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that could cause harm to the
air conditioner.
NOTICE This symbol indicates special notes.

Copyright ©2007 LG Electronics. Inc. All right reserved. -5-


LGE Internal Use Only
Only for training and service purposes
Safety Precautions

Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must
be followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.

WARNING This symbol indicates the possibility of death or serious injury.

CAUTION This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

WARNING
■ Installation
Do not use a defective or under- For electrical work, contact the Always ground the product.
rated circuit breaker. Use this dealer, seller, a qualified electrician,
appliance on a dedicated circuit. or an Authorized Service Center.
• There is risk of fire or electric • Do not disassemble or repair the • There is risk of fire or electric
shock. product. There is risk of fire or shock.
electric shock.

Install the panel and the cover Always install a dedicated cir- Use the correctly rated break-
of control box securely. cuit and breaker. er or fuse.
• There is risk of fire or electric • Improper wiring or installation may • There is risk of fire or electric
shock. cause fire or electric shock shock.

Copyright ©2007 LG Electronics. Inc. All right reserved. -6-


LGE Internal Use Only
Only for training and service purposes
Safety Precautions

Do not modify or extend the Do not install, remove, or re- Be cautious when unpacking
power cable. install the unit by yourself and installing the product.
(customer).
• There is risk of fire or electric • There is risk of fire, electric shock, • Sharp edges could cause injury.
shock. explosion, or injury. Be especially careful of the case
edges and the fins on the con-
denser and evaporator.

For installation, always con- Do not install the product on a Be sure the installation area
tact the dealer or an defective installation stand. does not deteriorate with age.
Authorized Service Center.
• There is risk of fire, electric shock, • It may cause injury, accident, or • If the base collapses, the air condi-
explosion, or injury. damage to the product. tioner could fall with it, causing
property damage, product failure,
and personal injury.

Do not let the air conditioner Take care to ensure that Do not place anything on the
run for a long time when the power cable could not be power cable.
humidity is very high and a pulled out or damaged during
door or a window is left open. operation.
• Moisture may condense and wet or • There is risk of fire or electric • There is risk of fire or electric
damage furniture. shock. shock.

Copyright ©2007 LG Electronics. Inc. All right reserved. -7-


LGE Internal Use Only
Only for training and service purposes
Safety Precautions

Do not plug or unplug the Do not touch(operate) the Do not place a heater or other
power supply plug during product with wet hands. appliances near the power
operation. cable.
• There is risk of fire or electric • There is risk of fire or electrical • There is risk of fire and electric
shock. shock. shock.

Do not allow water to run into Do not store or use flammable Do not use the product in a
electric parts. gas or combustibles near the tightly closed space for a long
product. time.
• It may cause There is risk of fire, • There is risk of fire or failure of • Oxygen deficiency could occur.
failure of the product, or electric product.
shock.

Gasolin

When flammable gas leaks, If strange sounds, or small or Stop operation and close the
turn off the gas and open a smoke comes from product. window in storm or hurricane.
window for ventilation before Turn the breaker off or discon- If possible, remove the prod-
turn the product on. nect the power supply cable. uct from the window before
the hurricane arrives.
• Do not use the telephone or turn • There is risk of electric shock or • There is risk of property damage,
switches on or off. There is risk of fire. failure of product, or electric shock.
explosion or fire

Copyright ©2007 LG Electronics. Inc. All right reserved. -8-


LGE Internal Use Only
Only for training and service purposes
Safety Precautions

Do not open the inlet grill of the product When the product is soaked Be cautious that water could
during operation. (Do not touch the elec- (flooded or submerged), contact not enter the product.
trostatic filter, if the unit is so equipped.) an Authorized Service Center.
• There is risk of physical injury, • There is risk of fire or electric • There is risk of fire, electric shock,
electric shock, or product failure. shock. or product damage.

Ventilate the product from time to time when Turn the main power off when cleaning or
operating it together with a stove, etc. maintaining the product.
• There is risk of fire or electric shock. • There is risk of electric shock.

When the product is not be used for a long time, dis- Take care to ensure that nobody could step on
connect the power supply plug or turn off the breaker. or fall onto the outdoor unit.
• There is risk of product damage or failure, or unintend- • This could result in personal injury and product dam-
ed operation. age.

CAUTION
■ Installation
Always check for gas (refrigerant) leak- Install the drain hose to ensure that Keep level even when
age after installation or repair of product. water is drained away properly. installing the product.
• Low refrigerant levels may cause • A bad connection may cause water • To avoid vibration or water leak-
failure of product. leakage. age.

90°

Copyright ©2007 LG Electronics. Inc. All right reserved. -9-


LGE Internal Use Only
Only for training and service purposes
Safety Precautions

Do not install the product Use two or more people to lift Do not install the product
where the noise or hot air and transport the product. where it will be exposed to
from the outdoor unit could sea wind (salt spray) directly.
damage the neighborhoods.
• It may cause a problem for your • Avoid personal injury. • It may cause corrosion on the
neighbors. product. Corrosion, particularly on
the condenser and evaporator fins,
could cause product malfunction or
inefficient operation.

■ Operational
Do not expose the skin directly to cool air for Do not use the product for special purposes,
long periods of time. such as preserving foods, works of art, etc. It
(Don't sit in the draft.) is a consumer air conditioner, not a precision
refrigeration system.
• This could harm to your health. • There is risk of damage or loss of property.

Do not block the inlet or outlet Use a soft cloth to clean. Do Do not touch the metal parts of
of air flow. not use harsh detergents, sol- the product when removing the
vents, etc. air filter. They are very sharp!
• It may cause product failure. • There is risk of fire, electric shock, • There is risk of personal injury.
or damage to the plastic parts of
the product.

x
Wa Thinner

Copyright ©2007 LG Electronics. Inc. All right reserved. - 10 -


LGE Internal Use Only
Only for training and service purposes
Safety Precautions

Do not step on or put anyting Always insert the filter secure- Do not insert hands or other
on the product. (outdoor ly. Clean the filter every two objects through the air inlet or
units) weeks or more often if neces- outlet while the product is
sary. operated.
• There is risk of personal injury and • A dirty filter reduces the efficiency • There are sharp and moving parts
failure of product. of the air conditioner and could that could cause personal injury.
cause product malfunction or dam-
age.

Do not drink the water drained Use a firm stool or ladder Replace the all batteries in the
from the product. when cleaning or maintaining remote control with new ones
the product. of the same type. Do not mix
old and new batteries or dif-
ferent types of batteries.
• It is not sanitary and could cause • Be careful and avoid personal • There is risk of fire or explosion
serious health issues. injury.

Do not recharge or disassemble the batteries. If the liquid from the batteries gets onto your
Do not dispose of batteries in a fire. skin or clothes, wash it well with clean water.
Do not use the remote if the batteries have
leaked.
• They may burn or explode. • The chemicals in batteries could cause burns or other
health hazards.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 11 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

Dimensions
Indoor Unit
1. Split Type Indoor 2. Art Cool Type Indoor Unit

W D

D
W

Pipe Hole

Hanger Hole

Fix Hole

Installation plate

Model
SQ SR ST S4 S5 SP
Dimension 7k, 9k 9k, 12k 18k, 24k 7k, 9k, 12k 18k, 24k 9k, 12k

W mm 824 900 1080 840 1090 570

H mm 260 285 314 270 300 568

D mm 155 156 172 153 178 137

Copyright ©2007 LG Electronics. Inc. All right reserved. - 12 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

3. Art Cool Deluxe Type

SZ,SU,S3 SE

H
H

D
D
W
W

Installation plate

Installation plate

MODEL SZ SU S3 SE
DIM Unit 7K 9K, 12K 18K, 24K 7K, 9K, 12K

W mm 900 1030 1170 895

H mm 272 290 315 282

D mm 135 153 173 165

Copyright ©2007 LG Electronics. Inc. All right reserved. - 13 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

4. Duct Type

W D

BH/BG

W
D
W D

H
H

BP BT/BT1/B1/B2

MODEL BT BT1 BH BG BP B1 B2
DIM 9K/12K 18K 18K/24K 30K/36K 9K/12K 9K/12K 18K/24K

W(mm) 708 1060 880 1180 580 820 1100

H(mm) 230 230 260 298 300 190 190

D(mm) 537 357 450 450 750 575 575

Copyright ©2007 LG Electronics. Inc. All right reserved. - 14 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

5. CVT Type

VB(18K/24K) W
H

D
63mm
38mm

39
26 2m
5m m 250mm
m

mm
36

46
8m
m 175mm mm
76
10

(Installation Plate)
(Rear Side)
mm
36

VE(8K/12K)
D

Installation plate

MODEL VE VB
DIM Unit 9K/12K 18K/24K

W mm 900 1200

H mm 285 615

D mm 156 205

Copyright ©2007 LG Electronics. Inc. All right reserved. - 15 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

6. CST Type - TC,TC1 (9K/12K)

1,000 (Ceiling opening)


931.6
893.4 (Hanging bolt)
860

328.4 (Hanging bolt) 30.8


430 (Ceiling opening)
390
4
931.6
893.4
16.7 860

30.8
1 7 846

3 2

50

328.4
390
42.7
194.4

164
155

37
91.6
97.7
116.3 Ø80 430 180
141.8

180
180
91.6

Ø55 130

1050

694.5

5
480

(unit : mm)
Number Name Descripition
1 Liquid pipe connection ø6.35 flare
2 Gas pipe connection ø9.52 flare
3 Drain pipe connection
4 Power supply connection
5 Air discharge grill
6 Air suction grill

Copyright ©2007 LG Electronics. Inc. All right reserved. - 16 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

7. CST Type - TE(1) (9K/12K/18K)

600 (Ceiling opening)

39.5 521(Hanging bolt) 39.5

450 (Hanging bolt) 75

600 (Ceiling opening)


269
570 Unit size

570 Unit size


670
670

75
Unit:mm

670 570
450

5
570

521
670

CLOSE OPEN OPEN CLOSE

40
4
1 2
30

110 110
269

90

90

190.5
30

160
120.4

52

(unit : mm)
Number Name Descripition
1 Liquid pipe connection ø6.35 flare
2 Gas pipe connection 9k: Ø9.52, 12k: Ø9.52, 18k: Ø12.7 flare
3 Drain pipe connection
4 Power supply connection
5 Air discharge grill
6 Air suction grill

Copyright ©2007 LG Electronics. Inc. All right reserved. - 17 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

8. CST Type - TF (24K/30K)


790 (Ceiling opening)
572(Hanging bolt)
109 109

66
790 (Ceiling opening)
658 (Hanging bolt)
292 744 Unit size

744 Unit size


850
850

66
Unit:mm

850
744
658

5
850

572
744
6

70
4
1 2
117

110 110
292

90

90

150
212
192

54
30

(unit : mm)
Number Name Descripition
1 Liquid pipe connection ø6.35 flare
2 Gas pipe connection ø12.7 flare-24K, ø15.88 flare-30K
3 Drain pipe connection
4 Power supply connection
5 Air discharge grill
6 Air suction grill

Copyright ©2007 LG Electronics. Inc. All right reserved. - 18 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

9. CST Type - TH (24K)


862 (Ceiling opening)
688(Hanging bolt)
87 87

28
862 (Ceiling opening)
806 (Hanging bolt)
255 840

950

840
950

28
Unit:mm

950
840
608

5
950

688
840
6

70
4
1 2
117

110 110
225

90

90

150
212
192

54
30

(unit : mm)
Number Name Descripition
1 Liquid pipe connection ø6.35 flare
2 Gas pipe connection ø12.7 flare-24K, ø15.88 flare-30K
3 Drain pipe connection
4 Power supply connection
5 Air discharge grill
6 Air suction grill

Copyright ©2007 LG Electronics. Inc. All right reserved. - 19 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

10. CST Type - TD(36K)

875 (Ceiling opening)

45 785 (Hanging bolt) 45

101.5 672 (Hanging bolt) 101.5


875 (Ceiling opening)
288

950 840 Unit size

840 Unit size


950

950
Unit:mm

840
678
950

785
840

6
55

4
40
2
1
30

110 110
290

210.5
52 180
90

90
140

Fresh Air Inlet


3

(unit : mm)
Number Name Descripition
1 Liquid pipe connection ø6.35 flare
2 Gas pipe connection ø15.88 flare
3 Drain pipe connection
4 Power supply connection
5 Air discharge grill
6 Air suction grill

Copyright ©2007 LG Electronics. Inc. All right reserved. - 20 -


LGE Internal Use Only
Only for training and service purposes
Dimensions

Outdoor Unit
D

W W

L1
D
L2
30K/40K
L3
H

L6 L5 L7
L4

18K/24K

MODEL UL UE UE1 UE2 UH


DIM 14K, 16K 14K, 18K 24K 30K 40K
W mm 770 870 870 870 900

H mm 540 655 800 1060 1165

D mm 245 320 320 320 370

L1 mm 287 370 370 360 460

L2 mm 21 25 25 20 45

L3 mm 530 775 775 1040 1135

L4 mm 10 25 25 20 30

L5 mm 518 546 546 550 550

L6 mm 126 160 160 160 175

L7 mm 126 160 160 165 175

Copyright ©2007 LG Electronics. Inc. All right reserved. - 21 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Product Specifications
Indoor Unit
Indoor Unit Type Wall Mounted

Model AMNH076LQL0 AMNH096LQL0 AMNH096LRL0 AMNH126LRL0 AMNH186LTL0 AMNH246LTL0


Rated Cooling Capacity ★ kcal/hr(W) 1764(2051) 2267(2638) 2267(2638) 3024(3515) 4536(5275) 5544(6446)
Btu/hr 7000 9000 9000 12000 18000 22000
Rated Heating Capacity ★ kcal/hr(W) 2016(2343) 2520(2929) 2520(2929) 3326(3867) 4990(5803) 6099(7091)
Btu/hr 8000 10000 10000 13200 19800 24200
Air Circulation H/M/L CMM(CFM) 5.5(194) 8.5(300) 8.5(300) 9.0(318) 13(459) 14(494)
Setting temperature range °C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 8.4 8.4 14.4 14.4 22 29
Model IC-8415LG62A IC-8415LG62A IC-8420LG48A IC-8420LG48A AMR-023E2 AMR-023E5
No. of Poles 4 4 4 4 4 6
Input W 25 25 37 37 54 59
Running Current A 0.11 0.11 0.16 0.16 0.21 0.21
Capacitor µF/Vac 0.9 / 400 0.9 / 400 0.9 / 400 0.9 / 400 2.0 / 370 2.0 / 370
Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
No. Used / Diameter EA/inch(mm) 1/3.43(87) 1/3.43(87) 1/3.43(87) 1/3.43(87) 1/3.74(95) 1/3.74(95)
Fan RPM Cooling(H/M/L) rpm 1080 / 970 / 880 1170 / 1100 / 1020 1200/1100/1000 1290 / 1200 / 1120 1140 / 1040 / 940 1260 / 1140 / 1000
Heating(H/M/L) rpm 1080 / 970 / 880 1170 / 1100 / 1020 1200/1100/1000 1290 / 1200 / 1120 1140 / 1040 / 940 1260 / 1140 / 1000
Noise Level(Sound Press,1m) H/M/L dBA 35 / 32 / 29 37 / 33 / 31 35 / 33 / 31 39 / 36 / 34 42 / 39 / 36 46 / 43 / 39
Temperature controller Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.197(5.0) 0.197(5.0) 0.197(5.0) 0.197(5.0) 0.276(7.0) 0.276(7.0)
Fins per inch 19 19 20 20 20 20
No. of Rows & Column 2R,10C 2R,10C 2R,12C 2R,12C 2R,13C 2R,13C
Dehumidification Rate l/h 1.0 1.2 1.4 1.8 2.0 2.5
Dimensions (W*H*D) inch(mm) 32.4*10.2*6.1(824*260*155) 32.4*10.2*6.1(824*260*155) 35.4*11.2*6.1(900*285*156) 35.4*11.2*6.1(900*285*156) 42.9*12.4*6.8(1090*314*172) 42.9*12.4*6.8(1090*314*172)
Net Weight kg(lbs) 7(15.4) 7(15.4) 8(17.6) 8(17.6) 12(26.5) 12(26.5)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Connection Gas inch(mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7)
Drain hose (ID Ø) mm 20 20 20 20 20 20
Packing Dimension (W*H*D) inch(mm) 35.4*9.2*13.4(900*233*340) 35.4*9.2*13.4(900*233*340) 38.4*9.2*14.6(976*233*372) 38.4*9.2*14.6(976*233*372) 45.9*10.0*15.3(1165*255*388) 45.9*10.0*15.3(1165*255*388)
Stuffing Quantity Without S/Parts 20/40ft 354/774 (360/780) 354/774 (360/780) 338/714 (340/720) 338/714 (340/720) 264/536 (270/540) 264/536 (270/540)
Front Panel Color "★" Position Morning Beige Morning Beige Morning Beige Morning Beige Morning Beige Morning Beige

Indoor Unit Type ART COOL DELUXE

Model AMNH076DZ*0 AMNH096DU*0 AMNH126DU*0 AMNH186D3*0 AMNH246D3*0


Rated Cooling Capacity ★ kcal/hr(W) 1764(2051) 2267(2638) 2772(3224) 4536(5275) 5796(6740)
Btu/hr 7000 9000 12000 18000 23000
Rated Heating Capacity ★ kcal/hr(W) 1940(2257) 2495(2901) 3049(3546) 4990(5803) 6426(7472)
Btu/hr 8000 10000 13200 19800 25500
Air Circulation H/M/L CMM(CFM) 5.5(194) 8.5(300) 9.0(318) 13(459) 14(494)
Setting temperature range °C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 4.7 7.8 7.8 25.6 25.6
Model OBM-1547P2 OBM-1547P2 OBM-1547P2 OBM-2510P2 OBM-2510P2
No. of Poles 4 4 4 4 4
Input W 27 40 40 58 58
Running Current A 0.12 0.18 0.18 0.15 0.21
Capacitor µF/Vac 0.9/400 0.9/400 0.9/400 2.0 / 370 2.0 / 370
Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
No. Used / Diameter EA/inch(mm) 1/3.43(87) 1/3.43(87) 1/3.43(87) 1/3.74(95) 1/3.74(95)
Fan RPM Cooling(H/M/L) rpm 1330/1230/1130 1320/1220/1120 1400/1300/1200 - -
Heating(H/M/L) rpm 1330/1230/1130 1320/1220/1120 1400/1300/1200 - -
Noise Level(Sound Press,1m) H/M/L dBA 35 / 32 / 29 37 / 33 / 31 39 / 36 / 34 40/38/36 44/42/40
Temperature controller Thermistor Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.197(5.0) 0.197(5.0) 0.197(5.0) 0.276(7.0) 0.276(7.0)
Fins per inch 19 19 19 20 20
No. of Rows & Column 2R,12C 2R,12C 2R,12C 2R,13C 2R,13C
Dehumidification Rate l/h 1.0 1.2 1.5 2 2.5
Dimensions (W*H*D) inch(mm) 42.9*12.4*6.8(1090*314*172) 35.4*10.7*5.3(900*272*135) 40.6*11.4*6.0(1030*290*153) 46.1*24.4*6.81 (1170*315*173) 46.1*24.4*6.81 (1170*315*173)
Net Weight kg(lbs) 8.1(17.9) 9.5(20.9) 9.5(20.9) 13(28.7) 13(28.7)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Connection Gas inch(mm) 3/8(9.52) 3/8(9.52) 3/8(9.52) 1/2 (12.7) 1/2 (12.7)
Drain hose (ID Ø) mm 20 20 20 20 20
Packing Dimension (W*H*D) inch(mm) 38.8*8.7*14.3(985*220*363) 44.0*8.9*14.8(1117*225*377) 44.0*8.9*14.8(1117*225*377) 49.4*15.3*10.2 (1255*388*258) 49.4*15.3*10.2 (1255*388*258)
Stuffing Quantity Without S/Parts 20/40ft 340/720 324/684 324/684 234/495 234/495
Front Panel Color "★" Position R:Mirror, M:Metal, N:Walnut, W:White, B:Blue, C:Cherry

Note : 1.★ See the page "Combination Table"


2. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 22 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type ART COOL Mirror

Model AMNH07GDE*0[MC07AH*NE0] AMNH09GDE*0[MC09AH*NE0] AMNH12GDE*0[MC12AH*NE0]


Power supply Ø/V/Hz 1/ 220~240/ 50 1/ 220~240/ 50 1/ 220~240/ 50
Cooling capacity kW 2.05 2.64 3.52
Btu/h 7,000 9,000 12,000
Heating capacity kW 2.34 2.93 3.87
Btu/h 8,000 10,000 13,200
Current Nominal running current A 0.10 0.15 0.15
Fan Motor type BLDC BLDC BLDC
Fan type Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor output x Number of unit 4.7 X 1 7.8 X 1 7.8 X 1
Air flow rate cmm 7/6/4 8/7/5 10/8/6
(H/M/L) cfm 247/212/141 282/247/177 353/283/212
Capacitor µF/Vac - - -
Drive Direct Drive Direct Drive Direct Drive
Coil Row x column x FPI mm 2R x 12C x 19 2R x 12C x 19 2R x 12C x 19
Dimensions (WxHxD) Body mm(inch) 915x282x165 (36.0*11.1*6.5) 915x282x165 (36.0*11.1*6.5) 915x282x165 (36.0*11.1*6.5)
Weight Body kg(lbs) 8.1(17.9) 9.5(20.9) 9.5(20.9)
Air filter Long Life Filter Long Life Filter Long Life Filter
Sound level (H/M/L) dB(A)+3 30/25/21 31/26/22 35/28/24
Piping Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
connections Gas mm(inch) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
Dehumidification rate l/h 1.0 1.2 1.5
Safety devices Fuse, Thermal Protector for Fan Motor
Temperature sensor Thermistor Thermistor Thermistor
Referigerant R410A R410A R410A
Referigerant control LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD)
Connectable outdoor unit Multi F /F DX series Multi F /F DX series Multi F /F DX series
Power and transmission interunit cable No.x mm2 4*0.75 4*0.75 4*0.75

Indoor Unit Type Wall Mounted

Model AMNH07GD4L0 AMNH09GD4L0 AMNH12GD4L0 AMNH18GD5L0 AMNH24GD5L0


Nominal Cooling Capacity ★ kcal/h(W) 1764(2051) 2267(2638) 3024(3515) 4536(5275) 5796(6740)
Btu/h 7000 9,000 12,000 18,000 23,000
Nominal Heating Capacity ★ kcal/h(W) 2016(2343) 2520(2929) 3326(3867) 4990(5803) 6426(7472)
Btu/h 8000 10,000 13,200 19,800 25,500
Air Circulation H/M/L CMM(CFM) 5.5(194) 8.2(290) 9.0(318) 13(459) 14(494)
Setting temperature range(cool/heat) °C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 20 20 20 20 20
Model SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3
Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
No. Used / Diameter EA/inch(mm) 1/3.74(95) 1/3.74(95) 1/3.74(95) 1/3.94(100) 1/3.94(100)
Fan RPM Cooling(H/M/L) rpm 1000/870/750 1140/1000/800 1250/1080/970 1200/1100/1000 1360/1260/1100
Heating(H/M/L) rpm 1000/870/750 1140/1000/800 1250/1080/970 1200/1100/1000 1360/1260/1100
Noise Level (Sound Press,1m) H/M/L dBA 29 / 25 / 20 33 / 29 / 22 36 / 32 / 29 37 / 34 / 31 41 / 39 / 34
Temperature controller Thermistor Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.197(5.0) 0.197(5.0) 0.197(5.0) 0.276(7.0) 0.276(7.0)
Fins per inch 20 20 20 20 20
No. of Rows & Column 2R,15C 2R,15C 2R,15C 2R,15C 2R,15C
Dehumidification Rate l/h 0.9 1.1 1.2 2.3 3.0
Dimensions (W*H*D) inch(mm) 33.0*10.6*6.0(840*270*153) 33.0*10.6*6.0(840*270*153) 33.0*10.6*6.0(840*270*153) 42.9*11.8*7.0(1090*300*180) 42.9*11.8*7.0(1090*300*180)
Net Weight kg(lbs) 7(15.4) 7(15.4) 7(15.4) 13(28.7) 13(28.7)
Piping Connection Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas inch(mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7)
Drain hose (ID Ø) mm 20 20 20 20 20
Packing Dimension (W*H*D) inch(mm) 35.7*13.1*8.8(906*332*223) 35.7*13.1*8.8(906*332*223) 35.7*13.1*8.8(906*332*223) 45.9*15.2*9.7(1165*387*246) 45.9*15.2*9.7(1165*387*246)
Stuffing Quantity With(Without) S/Parts 20/40ft 437/906 (432/896) 437/906 (432/896) 437/906 (432/896) 270/558 (267/552) 270/558 (267/552)
Front Panel Color "★" Position Morning Beige Morning Beige Morning Beige Morning Beige Morning Beige

Copyright ©2007 LG Electronics. Inc. All right reserved. - 23 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type ARTCOOL DELUXE

Model AMNH07GDZ*0 AMNH09GDU*0 AMNH12GDU*0 AMNH18GD3*0 AMNH24GD3*0


Nominal Cooling Capacity ★ kcal/h(W) 1764(2051) 2267(2638) 3024(3515) 4536(5275) 5796(6740)
Btu/h 7000 9000 12000 18,000 23,000
Nominal Heating Capacity ★ kcal/h(W) 2016(2343) 2520(2929) 3326(3867) 4990(5803) 6426(7472)
Btu/h 8000 10000 13200 19,800 25,500
Air Circulation H/M/L CMM(CFM) 5.5(194) 8.5(300) 9.0(318) 13(459) 14(494)
Setting temperature range(cool/heat) °C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 20 20 20 20 20
Model SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3
Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
No. Used / Diameter EA/inch(mm) 1/3.43(87) 1/3.43(87) 1/3.43(87) 1/3.74(95) 1/3.74(95)
Fan RPM Cooling(H/M/L) rpm 1150/1032/940 1280/1208/1147 1345/1273/1213 1330/1254/1123 1400/1332/1188
Heating(H/M/L) rpm 1150/1032/940 1280/1208/1147 1345/1273/1213 1330/1254/1123 1400/1332/1188
Noise Level (Sound Press,1m) H/M/L dBA 31/29/27 33/31/29 35/31/29 39/37/35 43/41/38
Temperature controller Thermistor Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.197(5.0) 0.197(5.0) 0.197(5.0) 0.276(7.0) 0.276(7.0)
Fins per inch 19 19 19 20 20
No. of Rows & Column 2R,12C 2R,12C 2R,12C 2R,13C 2R,13C
Dehumidification Rate l/h 1.0 1.2 1.5 2.0 2.5
Dimensions (W*H*D) inch(mm) 35.4*10.7*5.6 (900*272*143) 40.6*11.4*6.0 (1030*290*153) 40.6*11.4*6.0 (1030*290*153) 46.1*24.4*6.81(1170*315*173)" "46.1*24.4*6.81(1170*315*173)
Net Weight kg(lbs) 8.1(17.9) 9.5(20.9) 9.5(20.9) 13(28.7) 13(28.7)
Piping Connection Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas inch(mm) 3/8(9.52) 3/8(9.52) 3/8(9.52) 1/2 (12.7) 1/2 (12.7)
Drain hose (ID Ø) mm 20 20 20 20 20
Packing Dimension (W*H*D) inch(mm) 38.8*14.3*8.7 (985*363*220) 44.0*14.8*8.9 (1117*377*225) 44.0*14.8*8.9 (1117*377*225) "49.4*15.3*10.2(1255*388*258)" "49.4*15.3*10.2(1255*388*258)"
Stuffing Quantity With(Without) S/Parts 20/40ft 340/720 324/684 324/684 234/495 234/495
Front Panel Color "★" Position R:Mirror,M:Metal,N:Walnut,W;White,B:Blue,C:Cherry

Note : 1.★ See the page "Combination Table"


2. Due to our policy of innovation some specifications may be changed without notification.

Indoor Unit Type ART COOL

Model AMNH096AP*1 AMNH126AP*1


Rated Cooling Capacity ★ kcal/hr(W) 2267(2638) 2772(3224)
Btu/hr 9000 12000
Rated Heating Capacity ★ kcal/hr(W) 2520(2929) 3049(3546)
Btu/hr 10000 13200
Air Circulation H/M/L CMM(CFM) 7.5(264) 8.5(300)
Setting temperature range °C 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 24 24
Model SIC-39CV-D828-1 SIC-39CV-D828-1
No. of Poles 8 8
Input W 18 18
Running Current A 0.08 0.08
Capacitor µF/Vac - -
Fan Type Turbo Fan Turbo Fan
No. Used / Diameter EA/inch(mm) 1/24.32(617.7) 1/24.32(617.7)
Fan RPM Cooling(H/M/L) rpm 510/350/290 560/460/360
Heating(H/M/L) rpm 510/350/290 560/460/360
Noise Level(Sound Press,1m) H/M/L dBA 38 / 35 /32 43 / 40 / 33
Temperature controller Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.197(5.0) 0.197(5.0)
Fins per inch 20 20
No. of Rows & Column 2R,20C 2R,20C
Dehumidification Rate l/h 1 1.2
Dimensions (W*H*D) inch(mm) 22.4*22.4*5.4 (570*568*137) 22.4*22.4*5.4 (570*568*137)
Net Weight kg(lbs) 11.5(25.4) 11.5(25.4)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35)
Connection Gas inch(mm) 3/8 (9.52) 3/8(9.52)
Drain hose (ID Ø) mm 20 20
Packing Dimension (W*H*D) inch(mm) 25.7*25.2*8.5(653*641*216) 25.7*25.2*8.5(653*641*216)
Stuffing Quantity Without S/Parts 20/40ft 239/539 239/539
Front Panel Color "★" Position M:Metal, B:Blue, D:Wood

Note : 1.★ See the page "Combination Table"


2. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 24 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type Ceiling Cassette - 1way Ceiling Cassette - 4way

Model AMNH096TCC0 AMNH126TCC0 AMNH126TEC0 AMNH186TEC0 AMNH246TFC0 AMNH(C)306TFC0 AMNH(C)366TDC0


Rated Cooling Capacity ★ 2267(2638)
kcal/hr(W) 3024(3515) 3024(3515) 4536(5275) 6048(7033) 7056(8206) 9072(10551)
Btu/hr 9000 12000 12000 18000 24000 28000 36000
Rated Heating Capacity ★ 2520(2929)
kcal/hr(W) 3326(3867) 3326(3867) 4990(5803) 6653(7736) 7761(9027) 9979(11600)
Btu/hr 10000 13200 13200 19800 26400 30800 39600
Air Circulation H/M/L CMM(CFM) 9(317) 10(353) 11(353) 13(459) 15/14/13(53/494/459) 18(636) 25/23/21(883/812/742)
External Static Pressure mmAq - - - - - - -
Setting temperature range 18~30 / 16~30
°C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 14 14 18.4 22.4 40.3 45 52.5
Model AMR-023E7 AMR-023E7 IC-9630LGAE IC-9630LGAC OBM-350292 OBM-401592 IC-1630LGPJ
No. of Poles 4 4 6 6 6 6 6
Input W 50 50 75 90 121 146 175
Running Current A 0.56 0.56 0.35 0.75 0.53 0.67 0.8
Capacitor µF/Vac 0.9/400 0.9/400 2.5/440 2.5/440 4/440 4/440 4/450
Fan Type Cross Flow Fan Cross Flow Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan
No. Used / Diameter EA/inch(mm) 1/4(102) 1/4(102) 1/13.0(330) 1/13.0(330) 1/15.0(382) 1/15.0(382) 1/15.0(382)
Fan RPM Cooling(H/M/L) rpm 900 / 800 / 700 1000 / 900 / 800 670 / 620 / 550 720 / 670 / 620 600/540480 660/590/530 550/510/470
Heating(H/M/L) rpm 900 / 800 / 700 1000 / 900 / 800 670 / 620 / 550 720 / 670 / 620 600/540480 660/590/530 550/510/470
Noise Level(Sound Press,1m) H/M/L dBA 35 /32 / 28 37 / 33 / 29 38 / 35 / 32 41 /39 / 37 43/41/39 44/41/39 40/38/36
Temperature controller Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.275(7) 0.275(7) 0.275(7) 0.275(7) 0.275(7) 0.275(7) 0.275(7)
Fins per inch 18 18 19 19 21 21 21
No. of Rows & Column 2R11C 2R11C 2R11C 2R11C 2R12C 2R12C 2R12C
Dehumidification Rate l/h 1.2 1.5 1.2 2.4 3 3.5 4
Dimensions (W*H*D) Indoor inch(mm) 33.8*15.3*7(860*390*190) 33.8*15.3*7(860*390*190) 22.4*10.5*22.4 (570*269*570) 22.4*10.5*22.4 (570*269*570) 29.3*11.5*29.4 (744*292*744) 29.3*11.5*29.4 (744*292*744) 33.0*33.0*11.3(840*840*288)
Panel inch(mm) 41.3*18.9*1.2(1050*480*30) 41.3*18.9*1.2(1050*480*30) 26.4*26.4*1.2(670*670*30) 26.4*26.4*1.2(670*670*30) 33.5*33.5*1.2(850*850*30) 33.5*33.5*1.2(850*850*30) 37.4*37.4*1.2(950*950*30)
Net Weight kg(lbs) 22(48.5) 22(48.5) 19(41.9) 19(41.9) 24(52.9) 24(52.9) 32(70.5)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Connection Gas inch(mm) 3/8(9.52) 3/8(9.52) 3/8(9.52) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7)
Drain hose (ID Ø) mm 32 32 32 32 32 32 32
Packing Dimension (W*H*D) inch(mm) 38.6*10.0*18.1 38.6*10.0*18.1(980*255*460) 25.2*13.0*25.2(640*330*640) 25.2*13.0*25.2(640*330*640) 32.6*14.4*32.6 (828*365*828) 32.6*14.4*32.6 (828*365*828) 36.4*13.8*36.4(925*350*925)
Stuffing Quantity Without S/Parts 20/40ft 263/539 263/539 189/378 189/378 84/168 84/168 30/64(36/72)

Indoor Unit Type Ceilling Cassette - 4way

Model AMNH09GTEF0[MT10AH NE1] AMNH12GTEF0[MT12AH NE1] AMNH18GTEF0[MT18AH NE1] AMNH24GTHF0[MT24AH NHO]


Power supply Ø/V/Hz 1/ 220~240/ 50 1/ 220~240/ 50 1/ 220~240/ 50 1/ 220~240/ 50
Cooling capacity kW 2.64 3.52 5.28 7.03
Btu/h 9000 12000 18000 24000
Heating capacity kW 2.93 3.87 5.8 7.74
Btu/h 10000 13200 19800 26400
Current Nominal running current A 0.35 0.35 0.75 0.8
Fan Motor type BLDC BLDC BLDC BLDC
Fan type Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Motor output x Number of unit 18.4 X 1 18.4 X 1 22.4 X 1 40.3 X 1
Air flow rate(H/M/L) cmm 8.5/7.5/6.5 9.5/8/6.5 12/10/9 17/15/13
cfm 300/265/230 336/283/230 424/353/318 600/530/459
Capacitor µF/Vac - - - -
Drive Direct Drive Direct Drive Direct Drive Direct Drive
Coil Row x Column x FPI mm 2R x 11C x 18 2R x 11C x 18 2R x 11C x 18 2R x 9C x 18
Dimensions Body mm(inch) 570*265*570(22.4*10.5*22.4)
570*265*570(22.4*10.5*22.4) 570*265*570(22.4*10.5*22.4) 840*840*225 (33.1*33.1*8.8)
(WxHxD) Decorative panel mm 670*30*670(26.4*1.2 *26.4)670*30*670(26.4*1.2 *26.4) 670*30*670(26.4*1.2 *26.4) 950*950*30 (37.4*37.4*1.2)
Weight Body kg(lbs) 19(41.9) 19(41.9) 19(41.9) 26(126.5)
Decorative panel kg(lbs) 3(6.6) 3(6.6) 3(6.6) 5(11)
Air filter Long Life Filter Long Life Filter Long Life Filter Long Life Filter
Sound level (H/M/L) dB(A)+3 33/29/24 36/34/27 41/35/30 32/29/26
Piping Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
connections Gas mm(inch) 9.52 (3/8) 9.52 (3/8) 12.7(1/2) 12.7(1/2)
Drain OD/ID mm 32/25 32/25 32/25 32/25
Dehumidification rate l/h 1.1 1.2 2.4 3
Safety devices Fuse, Thermal Protector for Fan Motor
Temperature sensor Thermistor Thermistor Thermistor Thermistor
Referigerant R410A R410A R410A R411A
Referigerant control LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD )
Connectable outdoor unit Multi F /F DX series Multi F /F DX series Multi F /F DX series Multi F /F DX series
Power and transmission interunit cable No.x mm2 4*0.75 4*0.75 4*0.75 4*0.75

Copyright ©2007 LG Electronics. Inc. All right reserved. - 25 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type Ceiling Cassette - 1way

Model AMNH09GTCC0 AMNH12GTCC0


Rated Cooling Capacity ★ kcal/hr(W) 2267(2638) 3024(3515)
Btu/hr 9000 12000
Rated Heating Capacity ★ kcal/hr(W) 2520(2929) 3326(3867)
Btu/hr 10000 13200
Air Circulation H/M/L CMM(CFM) 9(317) 10(353)
External Static Pressure mmAq - -
Setting temperature range °C 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 14 14
Model AMR-023E7 AMR-023E7
No. of Poles 4 4
Input W 50 50
Running Current A 0.56 0.56
Capacitor µF/Vac 0.9/400 0.9/400
Fan Type Cross Flow Fan Cross Flow Fan
No. Used / Diameter EA/inch(mm) 1/4(102) 1/4(102)
Fan RPM Cooling(H/M/L) rpm 900 / 800 / 700 1000 / 900 / 800
Heating(H/M/L) rpm 900 / 800 / 700 1000 / 900 / 800
Noise Level(Sound Press,1m) H/M/L dBA 35 /32 / 28 37 / 33 / 29
Temperature controller Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.275(7) 0.275(7)
Fins per inch 18 18
No. of Rows & Column 2R11C 2R11C
Dehumidification Rate l/h 1.2 1.5
Dimensions (W*H*D) Indoor inch(mm) 33.8*15.3*7(860*390*190) 33.8*15.3*7(860*390*190)
Panel inch(mm) 41.3*18.9*1.2(1050*480*30) 41.3*18.9*1.2(1050*480*30)
Net Weight kg(lbs) 22(48.5) 22(48.5)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35)
Connection Gas inch(mm) 3/8(9.52) 3/8(9.52)
Drain hose (ID Ø) mm 32 32
Packing Dimension (W*H*D) inch(mm) 38.6*10.0*18.1 38.6*10.0*18.1(980*255*460)
Stuffing Quantity Without S/Parts 20/40ft 263/539 263/539

Copyright ©2007 LG Electronics. Inc. All right reserved. - 26 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type Ceiling Cassette - 4way

Model AMNH096TEC0
Nominal Cooling Capacity★ kcal/h(W) 2267(2638)
Btu/h 9000
Nominal Heating Capacity★ kcal/h(W) 2520(2929)
Btu/h 10000
Air Circulation H/M/L CMM(CFM) 9.5/8/7(336/283/247)
Setting temperature range(cool/heat) °C 18~30 / 16~30
Output W 18.4
Fan motor Model IC-9630LGAE
No. of Poles 6
Input W 75
Running Current A 0.35
Capacitor µF/Vac 2.5/440
Type Turbo Fan
Fan
No. Used / Diameter EA/inch(mm) 1/13.0(330)
Noise Level
H/M/L dBA 38 / 35 / 32
(Sound Press,1.5m)
Temperature controller Thermistor
Tube Size (OD) inch(mm) 0.275(7)
Coil 19
Fins per inch
No. of Rows & Column 2R11C
Dehumidification Rate l/h 1.2
Indoor Unit inch(mm) 22.4*10.5*22.4 (570*269*570)
Dimensions (W*H*D)
Decorative Panel inch(mm) 26.4*1.2*26.4 (670*30*670)
Body kg(lbs) 19(41.9)
Net Weight
Panel kg(lbs) 3(6.6)
Liquid inch(mm) 1/4 (6.35)
Piping Connection 3/8 (9.52)
Gas inch(mm)
Drain hose (ID Ø) inch(mm) 1.26(32)
Packing Dimension Indoor Unit inch(mm) "25.2*13.0*25.2 (640*330*640)
(W*H*D) Decorative Panel inch(mm) "29.5*3.1*29.5 (750*80*750)
Stuffing Quantity With(Without) S/Parts 20/40ft 189/378(189/378)
Notes : 1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
4. : See the page "Combination Table"

Indoor Unit Type Ceiling Concealed Duct

Model AMNH096BTG0 AMNH126BTG0 AMNH186BTG0 AMNH096BPA0 AMNH126BPA0


Rated Cooling Capacity kcal/hr(W) 2268(2637) 3024(3516) 4536(5274) 2268(2637) 3024(3516)
Btu/hr 9000 12000 18000 9000 12000
Rated Heating Capacity kcal/hr(W) 2520(2930) 3326(3868) 4990(5802) 2520(2930) 3326(3868)
Btu/hr 10000 13000 19800 10000 13200
Air Circulation H/M/L CMM(CFM) 8/7/6(282/246/211) 10/9/8(352/317/282) 13.5/12/10(477/424/353) 11.5/10/8.5 11.5/10/8.5
External Static Pressure mmAq 2 2 2 4 4
Setting temperature range °C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 18~30
Fan motor Output W 35 35 47 118 118
Model YDK110-35-4L YDK110-35-4L YSK110-70-4L IC-13450LG31A IC-13450LG31A
No. of Poles 4 4 4 4 4
Input W 68 68 126 180 180
Running Current A 0.31 0.31 0.58 4.3 4.3
Capacitor µF/Vac 2.5/400 2.5/400 2.5/370 6/370 6/370
Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
No. Used / Diameter EA/inch(mm) 1/7.8(197) 1/7.8(197) 2/7.8(197) 1/Ø177 1/Ø177
Fan RPM Cooling(H/M/L) rpm 930/840/810 950/850/780 1000/900/800 1125/990/870 1125/990/870
Heating(H/M/L) rpm 930/840/810 950/850/780 1000/900/800 1125/900/870 1125/990/870
Noise Level(Sound Press,1m) H/M/L dBA 34/32/30 37/34/31 38/36/34 38/36/34 38/36/34
Temperature controller Thermistor Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0)
Fins per inch 18 18 18 18 18
No. of Rows & Column 2R,12C 3R,12C 2R, 12C 2R14C 3R14C
Dehumidification Rate l/h 1 1.2 2 1.6 2
Dimensions (W*H*D) inch(mm) 25.6*9.0*21.1(650*230*535) 25.6*9.0*21.1(650*230*535) 39.4*9.0*21.1(1000*230*535) 750*300*580(695*56.5*396) 750*300*580(695*56.5*396)
Net Weight kg(lbs) 22(48.5) 22(48.5) 29(63.9) 30(6) 30(6)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4(6.35) 1/4(6.35)
Connection Gas inch(mm) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 3/8(9.52) 3/8(9.52)
Drain hose (ID Ø) mm 25.4 25.4 25.4 25.4(OD) 25.4(OD)
Packing Dimension (W*H*D) inch(mm) 29.9*24.6*11.8(760*625*300) 29.9*24.6*11.8(760*625*300) 29.9*24.6*11.8(760*625*300) 845*370*760(735*90*435) 845*370*760(735*90*435)
Stuffing Quantity Without S/Parts 20/40ft 172/356 172/356 123/251 228/468 228/468
Front Panel Color "*" Position - - - NOBEL WHITE NOBEL WHITE

Note : 1.★ See the page "Combination Table"


2. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 27 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type Ceiling Concealed Duct

Model AMNH186BHA0 AMNH(C)246BHA0 AMNH(C)306BGA0 AMNH(C)366BGA0


Rated Cooling Capacity kcal/hr(W) 4536(5275) 6048(7034) 7560(8792) 9072(10551)
Btu/hr 18000 24000 30000 36000
Rated Heating Capacity kcal/hr(W) 4990(5803) 6653(7737) 8316(9671) 9979(11606)
Btu/hr 19800 26400 33000 39600
Air Circulation H/M/L CMM(CFM) 16.5/14.5/13(583/512/459) 18/16.5/14(636/583/494) 28/25/23(989/883/812) 32/29/26.5(1130/1024/936)
External Static Pressure mmAq 8 8 8 8
Setting temperature range °C 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 118 118 124 272
Model IC-13450LG13C IC-13450LG13C IC-13450LG13J IC-13450LG13A
No. of Poles 4 4 4 4
Input W 180 180 250 323
Running Current A 0.92 0.92 1.1 1.42
Capacitor µF/Vac 6/370 6/370 6/370 6/370
Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
No. Used / Diameter EA/inch(mm) 2/6.97(177) 2/6.97(177) 2/6.97(177) 2/6.97(177)
Fan RPM Cooling(H/M/L) rpm 1356/-/1270 1417/1350/1255 1415/1360/1290 1415/1360/1290
Heating(H/M/L) rpm 1356/-/1270 1417/1350/1255 1415/1360/1290 1415/1360/1290
Noise Level(Sound Press,1m) H/M/L dBA 36/34/32 37/35/33 40/38/36 42/40/38
Temperature controller Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.275(7) 0.275(7) 0.275(7) 0.275(7)
Fins per inch 21 21 21 21
No. of Rows & Column 3R10C 3R10C 3R 12C 3R 12C
Dehumidification Rate l/h 2.0 2.5 3 3.5
Dimensions (W*H*D) inch(mm) 34.6*10.2*17.7 (880*260*450) 34.6*10.2*17.7 (880*260*450) 46.4*11.7*17.7(1180*298*450) 46.4*11.7*17.7(1180*298*450)
Net Weight kg(lbs) 35(77.2) 35(77.2) 38(83.8) 38(83.8)
Piping Liquid inch(mm) 1/4(6.35) 1/4(6.35) 1/4(6.35) 1/4(6.35)
Connection Gas inch(mm) 1/2(12.7) 1/2(12.7) 5/8(15.88) 5/8(15.88)
Drain hose (ID Ø) mm 25.4(OD) 25.4(OD) 25.4(OD) 25.4(OD)
Packing Dimension (W*H*D) inch(mm) 44.7*13.4*23.0(1135*340*585) 44.7*13.4*23.0(1135*340*585) 18.5*14.8*23.0(1435*375*585) 18.5*14.8*23.0(1435*375*585)
Stuffing Quantity Without S/Parts 20/40ft 120/252 120/252 95/191 95/191

Indoor Unit Type Ceiling & Floor(Convertible)

Model AMNH096VEA0 AMNH126VEA0 AMNH186VBA0 AMNH246VBA0


Rated Cooling Capacity kcal/hr(W) 2268(2637) 3024(3516) 4536(5274) 6048(7032)
Btu/hr 9000 12000 18000 24000
Rated Heating Capacity kcal/hr(W) 2520(2930) 3326(3867) 4990(5801) 6350(7384)
Btu/hr 10000 132000 19800 25200
Air Circulation H/M/L CMM(CFM) 7.8/6.4/5.0(276/226/177) 10.0/8.3/6.5(353/293/230) 135./12/11(477/424/388) 15/13.5/12(530/477/424)
External Static Pressure mmAq - - - -
Setting temperature range °C 18-30/16-30 18-30/16-30 18~30 / 16~30 18~30 / 16~30
Fan motor Output W 14.5 17.5 30 35
Model IC-18422LG31B IC-18422LG31A IC-9430LGCM IC-9430LGCM
No. of Poles 4 4 4 4
Input W 35 43 53 63
Running Current A 0.18 0.23 0.23 0.27
Capacitor µF/Vac 1.5/370 1.5/370 1.5/370 1.5/370
Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
No. Used / Diameter EA/inch(mm) 1/3.7(95) 1/3.7(95) 1/3.1(80) 1/3.1(80)
Fan RPM Cooling(H/M/L) rpm 960/870/760 1240/1120/900 1090/990/890 1160/1060/960
Heating(H/M/L) rpm 960/870/760 1240/1120/900 1090/990/890 1160/1060/960
Noise Level(Sound Press,1m) H/M/L dBA 36/32/28 40/36/31 43 / 40 / 37 45 / 42 / 39
Temperature controller Thermistor Thermistor Thermistor Thermistor
Coil Tube Size (OD) inch(mm) 0.197(5) 0.197(5) 0.275(7) 0.275(7)
Fins per inch 20 20 18 20
No. of Rows & Column 2R 12C 2R 12C 2R 12C 2R 14C
Dehumidification Rate l/h 1 1.2 2.3 3.2
Dimensions (W*H*D) inch(mm) 35.4*7.9*19.3 (900*200*490) 35.4*7.9*19.3 (900*200*490) 47.24*24.21*8.07(1200*615*205) 47.24*24.21*8.07(1200*615*205)
Net Weight kg(lbs) 12(26.5) 12(26.5) 30(66.1) 30(66.1)
Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) 1/4(6.35) 1/4(6.35)
Connection Gas inch(mm) 3/8 (9.52) 3/8 (9.52) 1/2(12.7) 1/2(12.7)
Drain hose (ID Ø) mm 20 20 20 20
Packing Dimension (W*H*D) inch(mm) 38.2*11.2*22.2 (970*285*565) 38.2*11.2*22.2 (970*285*565) 50*10.9*27(1272*278*686) 50*10.9*27(1272*278*686)
Stuffing Quantity Without S/Parts 20/40ft 189/383 189/383 102/219 102/219

Note : 1.★ See the page "Combination Table"


2. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 28 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Indoor Unit Type Ceiling Concealed Duct - Low Static


AMNH09GB1A0 AMNH12GB1A0 AMNH18GB2A0 AMNH24GB2A0
Model [MB09AHL N10] [MB12AHL N10] [MB18AHL N20] [MB09AHL N20]
Power Supply Ø/V/Hz 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50
Cooling Capacity kW 2.64 3.52 5.27 7.03
Btu/h 9,000 12,000 18,000 24,000
Heating Capacity kW 2.93 3.87 5.80 7.44
Btu/h 10,000 13,000 19,800 26,400
Current Nominal Running Current Cooling
Motor Type Induction Induction Induction Induction
Fan Fan Type Sirocco fan Sirocco fan Sirocco fan Sirocco fan
Motor Output x Number of Unit
Air flow rate(H/M/L) cmm 8.5/7.5/6.5 9.5/8.5/7.5 15/13.5/11.5 17/15/13.5
cfm 300/265/230 336/300/265 530/477/406 600/530/477
External Static Pressure mmAq
Capacitor µF/Vac
Drive Direct Drive Direct Drive Direct Drive Direct Drive
Coil Row x Columns x FPI mm 2R x 12C x 21 2R x 12C x 21 2R x 11C x 21 3R x 10C x 18
Dimensions(WxHxD) Body mm(inch) 820*190*575(32.28*7.48*22.64) 820*190*575(32.28*7.48*22.64) 1,100*190*575(43.3*7.48*22.6) 1,100*190*575(43.3*7.48*22.6)
Weight Body kg(lbs) 20.5(45.2) 20.5(45.2) 29.5 (65) 30(66.1)
Air filter H/M/L Long Life Filter Long Life Filter Long Life Filter Long Life Filter
Sound level(H/M/L) dBA 31/26/25 33/31/26 34/31/29 36/34/32
Piping Connections Liquid mm(inch) 6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4)
Gas mm(inch) 9.52(3/8) 9.52(3/8) 12.7(1/2) 12.7(1/2)
Drain(Out diameter) mm 32/20 32/20 32/20 32/20
Dehumidification Rate l/h 1.0 1.2 2.0 2.5
Safety devices Fuse, Thermal Protector for Fan Motor
Temperature sensor TherMistor TherMistor TherMistor TherMistor
Referigerant R410A R410A R410A R410A
Referigerant control LEV(In Outdoor unit or BD) LEV(In Outdoor unit or BD) LEV(In Outdoor unit or BD) LEV(In Outdoor unit or BD)
Connectable outdoor unit Mult F/F DX series Mult F/F DX series Mult F/F DX series Mult F/F DX series
power and transmission interunit cable No.x mm2 4*0.75 4*0.75 4*0.75 4*0.75

Copyright ©2007 LG Electronics. Inc. All right reserved. - 29 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Outdoor Unit - Multiple piping models

Model A2UW146FA0 A2UW146FA1 A2UW186FA0 A3UW186FA0 A3UW246FA0 A4UW246FA0 A4UW306FA0


Cooling Capacity ★ kcal/hr 1159~4031 1159~4031 1159~5443 1159~5443 1159~7257 1159~7257 1159~9072
W 1348~4688 1348~4688 1348~6330 1348~6330 1348~8,440 1348~8,440 1348~10549
Btu/hr 4600~16000 4600~16000 4600~21600 4600~21600 4600~28800 4600~28800 4600~36000
Heating Capacity ★ kcal/hr 1210~4535 1210~4535 1210~6249 1210~6249 1210~8063 1210~8063 2116~10332
W 1407~5274 1407~5274 1407~7268 1407~7268 1407~9376 1407~9376 2461~12014
Btu/hr 4800~18000 4800~18000 4800~24800 4800~24800 4800~32000 4800~32000 8,400~41,000
Input ★ Cooling/Heating W 380~1450/450~1350 380~1450/450~1350 420~2400/480~2600 420~2400/480~2600 440~2970/560~2950 440~2970/560~2950 450~3580/620~3580
Running Current ★ Cooling/Heating A 1.6~6.5/2.0~5.8 1.6~6.5/2.0~5.8 3.5~11.5/4~12 3.5~11.5/4~12 3.08~13.0/4.6~12.9 3.08~13.0/4.6~12.9 3.2~15.7/4.6~15.7
Starting Current Cooling/Heating A 1 1 1 1 28 28 28
Power Supply Ø,V,Hz 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50
Power Factor % 94~98 94~98 94~98 94~98 94~98 94~98 95~98
Max. Number of Connectable Indoor Units % 2 2 2 3 3 4 4
Compressor Type e-Scroll Rotary e-Scroll e-Scroll e-Scroll e-Scroll e-Scroll
(Invertor) O.L.P Type(model name) - - - - - - -
Compressor Type - - - - Rotary Rotary Rotary
(Constant) O.L.P Type(model name) - - - - MRA99150-9090 MRA99150-9090 INTERNAL
Refrigerant Charge g(oz), type 1650(59.97) at 7.5m 1650(59.97) at 7.5m 1650(59.97) at 7.5m 1650(59.97) at 7.5m 1950(68.78) at 7.5m 1950(68.78) at 7.5m 2500(88.18) at 7.5m
Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Control L.E.V L.E.V L.E.V L.E.V L.E.V L.E.V L.E.V
Coil Tube Size (OD) inch(mm) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0)
Fins per inch 18 18 18 18 18 18 18
No. of Rows & Column/No. 1R,28C 1R,28C 2R,28C 2R,28C 2R,36C 2R,36C 2R,48C
Fan Motor Model W IC28640LG28S IC28640LG28S IC28640LG28S IC28640LG28S IC28640LG28J IC28640LG28J IC9625LGSY
Output 120 120 120 120 130 130 65 * 2
Capacitor µF/Vac 6/370 6/370 6/370 6/370 6/370 6/370 2.0/370
Fan Type Propeller Propeller Propeller Propeller Propeller Propeller Propeller
No. Used / Diameter EA/inch(mm) 1/18.1(460) 1/18.1(460) 1/18.1(460) 1/18.1(460) 1/18.1(460) 1/18.1(460) 2/16.5(420)
Discharge Side / Top Side Discharge Side Discharge Side Discharge Side Discharge Side Discharge Side Discharge Side Discharge
Air Circulation CMM(CFM) 49(1730) 49(1730) 49(1730) 49(1730) 53(1872) 53(1872) 31(1094)*2
Noise Level(Sound Press,1m) dBA 50/47 50/47 51/48 51/48 51/48 51/48 50/46
Defrosting Invertion cycle Invertion cycle Invertion cycle Invertion cycle Invertion cycle Invertion cycle Invertion cycle
SVC Valve Liquid inch(mm) 1/4 (6.35)*2EA 1/4 (6.35)*2EA 1/4 (6.35)*2EA 1/4 (6.35)*3EA 1/4 (6.35)*3EA 1/4 (6.35)*4EA 1/4 (6.35)*4EA
Gas inch(mm) 3/8 (9.52)*2EA 3/8 (9.52)*2EA 3/8 (9.52)*2EA 3/8 (9.52)*3EA 3/8 (9.52)*3EA 3/8 (9.52)*4EA 3/8 (9.52)*4EA
Dimensions (W*H*D) inch(mm) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*808*320) 34.3*31.5*12.6 (870*808*320) 34.3*31.5*12.6 (870*1038*320)
Net Weight kg(lbs) 52(115) 52(115) 57(125.6) 75(165) 75(165) 75(165) 84(185)
Power Supply Cable No.* mm2 3*3.5 3*3.5 3*3.5 3*3.5 3*2.5 3*2.5 3*2.5
Interunit Cable No.* mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Max. Interunit Total of Each Room m 40 40 40 40 50 50 70
Piping Length For One Room m 25 25 25 25 25 25 25
Max. Installation Indoor Unit~Outdoor Unit m 15 15 15 15 15 15 15
Height Difference Indoor Unit~Indoor Unit m 7.5 7.5 7.5 7.5 7.5 7.5 7.5
Packing Dimension (W*H*D) inch(mm) 34.2*25.8*12.6(870*655*320) 34.2*25.8*12.6(870*655*320) 34.2*25.8*12.6(870*655*320) 34.2*25.8*12.6(870*655*320) 40.1*34.2*17.3 (1020*870*440) 40.1*34.2*17.3 (1020*870*440) 40.1*34.2*17.3 (1045*1140*440)
Stuffing Quantity Without S/Parts 20/40ft 81/171 81/171 81/171 81/171 54/114 54/114 51/111

Notes: 1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB - Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 7.5m - Interconnecting Piping Length 7.5 m
- Level Difference of Zero. - Level Difference of Zero.
2. Capacities are Net Capacities.
3. ★ : See the page "Combination Table"
4. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 30 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Outdoor Unit - Multiple piping models


Model
A2UW146FA2 A2UW166FA0 A2UW166FA1 A3UW186FA1 A4UW24GFA0 A4UW30GFA0

Cooling Capacity★ Btu/hr 4600-14000-16000 4600-16000-17500 4600-16000-17500 4600-18000-21600


W 1348-4100-4688 1348-4688-5128 1348-4688-5128 1348-5300-6329
kcal/hr 1159-3526-4031 1159-4031-4410 1159-4031-4410 1159-4558-5443
Heating Capacity★ Btu/hr 4800-16000-18000 4800-18000-19500 4800-18000-19500 4800-21600-24800
W 1407-4700-5274 1407-5274-5714 1407-5274-5714 1407-6300-7268
kcal/hr 1210-4042-4535 1210-4535-4914 1210-4535-4914 1210-5418-6249
Input★ Cooling W 380-1280-1500 380-1380-1600 380-1380-1600 480-1550-2350
Heating W 450-1220-1262 450-1400-1550 450-1400-1550 550-1650-2320
Running Current★ Cooling A 1.7-5.7-6.9 1.7-6.3-7.3 1.7-6.3-7.3 2.3-6.9-10.4
Heating A 2.1-5.9-6.9 2.1-6.4-7.1 2.1-6.4-7.1 2.6-7.3-10.3
Starting Current Cooling/Heating A 8 8 8 8
Power Supply Ø,V,Hz 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50~60 1,220~240,50~60
Power Factor % 94~98 94~98 94~98 94~98 94~98 94~98
Max. Number of Connectable Indoor Units 2 2 2 3 4 4
"Compressor(Inverter)" Type Rotary Twin Rotary Scroll Twin Rotary Rotary Rotary
Model 5RS102XAA GKT141NAA 5CS130X GKT141NAA 5KD240XCA21 5KD240XCA21
Motor Type DC Brushless Motor Synchronous Reluctance Motor DC Brushless Motor Synchronous Reluctance Motor DC Brushless Motor DC Brushless Motor
Quantity Ea 1 1 1 1 1 1
Motor Input W 980 1451 1405 1451 2405 2405
Oil Charge cc 320 570 480 570 900 900
Oil Type RB68A FVC68D RB68A FVC68D FV50S FV50S
O.L.P Type(model name) - - - - CS-7L N115 CS-7L N115
"Compressor(Constant)" Type - - - - - -
Model - - - - - -
Motor Type - - - - - -
Quantity Ea - - - - - -
Motor Input W - - - - - -
Oil Charge cc - - - - - -
Oil Type - - - - - -
O.L.P Type(model name) - - - - - -
Refrigerant charge Charge g(oz) 950(33.5) "at 7.5m" 950(33.5) "at 7.5m" 950(33.5) "at 7.5m" 1550(54.7) "at 7.5m" 2000(70.5) "at 7.5cm" 2000(70.5) "at 7.5cm"
Type R410A R410A R410A R410A R410 R410
Control L.E.V L.E.V L.E.V L.E.V L.E.V L.E.V
Coil Tube Size (OD) inch(mm) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0)
Fins per inch 18 18 18 18 18 18
No. of Rows & Column/No. 2R,24C 2R,24C 2R,24C 2R,28C 2R,36C 2R,36C
Fan motor Model OBM-3018P2 OBM-3018P2 OBM-3018P2 IC28640LG28S SIC-72FW-F1124-3 SIC-72FW-F1124-3
Output W 47 47 47 120 124 124
Capacitor µF/Vac 2.0/400 2.0/400 2.0/400 6/370 - -
Fan Type Propeller Propeller Propeller Propeller Propeller Propeller
No. Used / Diameter EA/inch(mm) 1/16.5(420) 1/16.5(420) 1/16.5(420) 1/18.1(460) 1/18.1(460) 1/18.1(460)
Discharge Side / Top Side Discharge Side Discharge Side Discharge Side Discharge Side Discharge Side Discharge
Air Circulation Outdoor CMM(CFM) 35(1236) 35(1236) 35(1236) 53(1766) 53(1766) 53(1766)
Noise Level(H/L) Sound Press,1m dB(A)±1 51 51 51 51/45 55 55
Defrosting Invertion cycle Invertion cycle Invertion cycle Invertion cycle Invertion cycle Invertion cycle
SVC Valve Liquid inch(mm) 1/4 (6.35)*2EA 1/4 (6.35)*2EA 1/4 (6.35)*2EA 1/4 (6.35)*3EA 1/4 (6.35)*2EA 1/4 (6.35)*2EA
Gas 3/8 (9.52)*2EA 3/8 (9.52)*2EA 3/8 (9.52)*2EA 3/8 (9.52)*3EA 3/8 (9.52)*2EA 3/8 (9.52)*2EA
Dimensions W*H*D inch(mm) 30.3*21.3*10 (770*540*245) 30.3*21.3*10 (770*540*245) 30.3*21.3*10 (770*540*245) 34.3*25.8*12.6 (870*655*320) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*800*320)
Net Weight Outdoor kg(lbs) 37(81.6) 37(81.6) 37(81.6) 52(115) ? ?
Power Supply Cable No.*mm2˜ 3*2.5 3*2.5 3*2.5 3*2.5 3*2.5 3*2.5
Interunit Cable 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Max. Interunit Piping Length Total of Each Room m 30 30 30 40 70 70
For One Room m 20 20 20 25 25 25
"Max. Installation Indoor Unit~Outdoor Unit m 15 15 15 15 15 15
Height Difference" Indoor Unit~Indoor Unit m 7.5 7.5 7.5 7.5 7.5 7.5
Packing Dimension W*H*D inch(mm) 36.2*22.8*14.2(920*580*360) 36.2*22.8*14.2(920*580*360) 36.2*22.8*14.2(920*580*360) 40.2*28.1*17.3 (1020*715*440)
Testing Combinations AMNH096LRL0+AMNH126LRL0 AMNH126LRL0+AMNH126LRL0 AMNH126LRL0+AMNH126LRL0 AMNH096LRL0*2 + AMNH126LRL0
Stuffing Quantity 20/40ft 144/312 144/312 144/312 0
Notes: 1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB - Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 7.5m - Interconnecting Piping Length 7.5 m
- Level Difference of Zero. - Level Difference of Zero.
2. Capacities are Net Capacities.
3. ★ : See the page "Combination Table"
4. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 31 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

Outdoor Unit - Distributor type models

Model A4UW306FA1 A6UW406FA0 A7UW486FA0 A8UW566FA0


Cooling Capacity ★ Btu/h 1159~9072 5000~48000 5000~57600 5000~67200
W 1348~10549 1465~14067 1465~16878 1465~19691
kcal/h 4600~36000 1260~12095 1260~14515 1260~16934
Heating Capacity ★ Btu/h 2116~10332 5500~53000 5800~63600 5800~75600
W 2461~12014 1612~15533 1700~18636 1700~22152
kcal/h 8,400~41,000 1386~13356 1462~16027 1462~19051
Input ★ Cooling/Heating W 450~3580/620~3580 600~4980/950~4810 750~5800/1450~5430 750~6600/1550~6800
Running Current ★ Cooling/Heating A 3.2~15.7/4.6~15.7 2.9~22.0/4.6~21.5 3.4~26.0/6.6~24.3 3.4~29.6/7.1~30.5
Starting Current Cooling/Heating A 28 67 43 74
Power Supply Ø,V,Hz 1,220~240,50 1,220~240,50 1,220~240,50 1,220~240,50
Power Factor % 95~98 91 ~ 98 90 ~ 97 90 ~ 97
Max. Number of Connectable Indoor Units 4 6 7 8
Compressor Type e-Scroll e-Scroll e-Scroll e-Scroll
(Invertor) O.L.P Type(model name) - - - -
Compressor Type Rotary Rotary Rotary Rotary
(Constant-1) O.L.P Type(model name) INTERNAL Internal Internal Internal
Compressor Type - - Rotary Rotary
(Constant-2) O.L.P Type(model name) - - Internal Internal
Refrigerant charge Charge g(oz) 2500(88.18) at 5m 4100(144.6) "at 5m" 7100(250.4) "at 5m" 7100(250.4) "at 5m"
Type R-410A R410A R410A R410A
Control L.E.V L.E.V L.E.V L.E.V
Coil Tube Size (OD) inch(mm) 0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0)
Fins per inch 18 18 18 18
No. of Rows & Column/No. 2R,48C 2R,52C 2R,53C*2 2R,53C*2
Fan motor Model IC9625LGSY IC28640LG28J ARE676E01 ARE676E01
Output W 65 * 2 120 * 2 270 270
Capacitor µF/Vac 2.0/370 6/370 10/370 10/370
Fan Type Propeller Propeller Propeller Propeller
No. Used / Diameter EA/inch(mm) 2/16.5(420) 2/18.1(460) 1/20.7(526) 1/20.7(526)
Discharge Side / Top Side Discharge Side Discharge Top Discharge Top Discharge
Air Circulation Outdoor CMM(CFM) 31(1094)*2 53(1872) *2 90(3179) 90(3179)
Noise Level(H/L) Sound Press,1m dB(A)±1 50/46 58/54 59/56 59/56
Defrosting Invertion cycle Invertion cycle Invertion cycle Invertion cycle
SVC Valve Liquid inch(mm) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas inch(mm) 5/8(15.88) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05)
Dimensions W*H*D inch(mm) 34.3*31.5*12.6 (870*1038*320) 35.4*45.8*14.5 (900*1,165*370) 31.7*59.5*28.7 (806*1,512*730) 31.7*59.5*28.7 (806*1,512*730)
Net Weight Outdoor kg(lbs) 84(185) 105(231) 142(312) 148(326)
Power Supply Cable No.* mm2 3*2.5 3*5.0 3*5.0 3*5.0
Interunit Cable No.* mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Max. Interunit Total Piping m 65 100 110 120
Piping Length Total Main Piping m 15 50 50 50
Total Branch Piping m 50 50 60 70
For One Room m 15 15 15 15
Max. Installation Indoor Unit~Outdoor Unit m 15 30 30 30
Height Difference Indoor Unit~Indoor Unit m 7.5 10 10 10
Packing Dimension W*H*D inch(mm) 40.1*34.2*17.3 (1045*1140*440) 41.7*48.0*18.3(1060*1220*465) 33.9*61.0*28.7(860*1,550*730) 33.9*61.0*28.7(860*1,550*730)
Stuffing Quantity Without S/Parts 20/40ft 51/111 27/55 20/42 20/42

Notes: 1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB - Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 7.5m - Interconnecting Piping Length 7.5 m
- Level Difference of Zero. - Level Difference of Zero.
2. Capacities are Net Capacities.
3. ★ : See the page "Combination Table"
4. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 32 -


LGE Internal Use Only
Only for training and service purposes
Product Specifications

LG Branch Distributor
Model PMBD3640 PMBD3630 PMBD3620 PMBD7230
Connectable Indoor Units Number of Indoor Units 1~4 1~3 1~2 1~3
Capacity Btu/h 7k/9k/12k/18k/24k 7k/9k/12k/18k/24k 7k/9k/12k/18k/24k 18k/24k/30k/36k
Casing color Paintingless Paintingless Paintingless Paintingless
Powre Source Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V
Power Consumption W 10 10 10 10
Runing Current A 0.05 0.05 0.05 0.05
Dimensions W*H*D inch(mm) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252)
Packing Dimension W*H*D inch(mm) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300)
Net Weight kg 5.0 4.9 4.8 5.0
Connecting Cable Direction Indoor Unit No. * mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Direction Outdoor Unit No. * mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Piping Connection Liquid inch(mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
(To Outdoor Unit) Gas inch(mm) 3/4(19.05) 3/4(19.05) 3/4(19.05) 3/4(19.05)
Piping Connection Liquid inch(mm) 1/4 (6.35)*4EA 1/4 (6.35)*3EA 1/4 (6.35)*2EA 1/4 (6.35)*3EA
(To Indoor Unit) Gas inch(mm) 3/8 (9.52)*4EA 3/8 (9.52)*3EA 3/8 (9.52)*2EA 1/2 (12.7), 3/8 (15.88)*2EA
Piping length m - - - -
Piping Elevation m - - - -
Drain hose Unusable
Heat Insulation Both Liquid and Gas pipes
Accessories Hanger EA 4 4 4 4
Screw EA 8 8 8 8
Manual EA 1 1 1 1

Note :
1. BD unit or Indoor Unit Max. Height - BD unit or Indoor Unit Min. Height - Max.10m
Set up the BD unit and Indoor Unit in 15m.
2. The piping connection must be suit the piping sizes of the indoor unit which will be connected.
(If need, use the connector which is included in the indoor unit)
3. The BD should be installed inside the building.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 33 -


LGE Internal Use Only
Only for training and service purposes
Installation

Installation
Read completely, then follow step by step.

Select the best location of indoor unit


1. Split Type Indoor Unit Front
• There should not be any heat source or steam near the
unit. Left
• There should not be any obstacles to prevent the air
circulation.
Rear left
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into considera- Down right
tion.
Right Rear right
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.

Connecting
cable

Drain hose

2. Art Cool Type Indoor Unit


• Do not have any heat or steam near the unit.
• Select a place where there are no obstacles in front
of the unit.
More than 10cm
• Make sure that condensation drainage can be conve-
niently routed away.
More than 50cm
Do not install near a doorway.
• Ensure that the space around the left and right of the
unit is more than 50cm. The unit should be installed
as high on the wall as possible, allowing a minimum
of 10cm from ceiling. More than 50cm
• Use a stud finder to locate studs to prevent unneces-
sary damage to the wall. More than 2m

Copyright ©2007 LG Electronics. Inc. All right reserved. - 34 -


LGE Internal Use Only
Only for training and service purposes
Installation

3. Art Cool Deluxe Type Indoor unit


• Do not have any heat or steam near the unit. More than 30cm
• Select a place where there are no obstacles in front of the More than 20cm
unit.
• Make sure that condensation drainage can be conveniently
routed away.
More than 30cm
Do not install near a doorway.
• Ensure that the space around the left and right of the unit is More than 2.3m
more than 20cm. The unit should be installed as high on the
wall as possible, allowing a minimum of 30cm from ceiling.
• Use a stud finder to locate studs to prevent unnecessary CAUTION
damage to the wall.
Install the indoor unit on the wall where the height
from the floors more than 2.3 meters.
4. Duct Type Indoor Unit
Install the air conditioner in the location that satisfies the
following conditions. Inspection hole
Top view (600X600)
• The place shall easily bear a load exceeding four times (unit: mm) Control box
the indoor unit’s weight.
• The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.

1000
600 600
• The place shall allow easy water drainage.(Suitable
dimension “H” is necessary to get a slope to drain as fig- Front
ure.)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical Front view
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the H
unit

5. CST Type Indoor Unit


• There should not be any heat source or steam near the
unit.
• There should not be any obstacles to the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
30 or more

Ceiling Ceiling Board


• A place where noise prevention is taken into considera- Ceiling Board
tion.
30 or less

• Do not install the unit near the door way.


or more

50 or 50 or
• Ensure the spaces indicated by arrows from the wall, more more
330 or less
Above 250
100

ceiling, or other obstacles.


• The indoor unit must have the maintenance space
Unit:cm
around.

Floor

Copyright ©2007 LG Electronics. Inc. All right reserved. - 35 -


LGE Internal Use Only
Only for training and service purposes
Installation

6. CVT Type Indoor Unit More than


20cm
• There should not be any heat source or steam near
the unit. More than
R

• There should not be any obstacles to prevent the air 20cm


circulation.
• A place where air circulation in the room will be good. More than eye-level
• A place where drainage can be easily obtained.
(Ceiling installation)
• A place where noise prevention is taken into consid- More than
20cm
eration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
R
More than
20cm

(Floor/Wall installation)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 36 -


LGE Internal Use Only
Only for training and service purposes
Installation

How to fix

1. Room Type Indoor Unit Installation


The mounting wall should be strong and solid Installation Plate
enough to protect it from the vibration.

1) Mount the installation plate on the wall with


four Type "A" screws.
(If mounting the unit on the concrete wall, consid- marking-off line
Type "A" screw
er using anchor bolts.)
Thread
• Always mount the Installation plate horizontally
by aligning the marking-off line by means of the Weight
thread and a level.

2) Drill the piping hole with 70mm dia. holecore The lower left and the right side of
drill. Installation Plate
• Line according to the arrows marked on lower
the left and the rght side of the Installation Plate.
The meeting point of the extended line is the C
center of the hole. Installation plate
D

B
• Drill the piping hole at either the right or the left
A
and the hole should be slightly slant to the out- Ø70mm Ø70mm

door side. Left rear piping Right rear piping

CHASSIS Distance(mm)
(Grade) A B C D
SQ(7/9k) 75 12 80 12
SR(9/12k) 0 40 20 40
ST(18/24k) 105 0 210 0

D
Installation plate B

Ø70mm
C A
Ø70mm
Left rear piping Right rear piping

CHASSIS Distance (mm)


(Grade) A B C D
S4 50 105 59 105
SE 65 110 85 110
S5 95 122 235 122

Copyright ©2007 LG Electronics. Inc. All right reserved. - 37 -


LGE Internal Use Only
Only for training and service purposes
Installation

2. Art Cool Type Indoor Unit 2) Cover pipe and cover side remove
The wall you select should be strong and solid enough • Remove two screws(for fixing cover pipe)
to prevent vibration • Pull up the cover side of desired connecting direc-
tion, then cover side is separated.
1) Open panel front • In case connecting direction is left or right, path
• First,Pull the grille bottom, then remove screws through the hole of cover side.
(2 pieces), and close grille bottom again.
• The moment of lifting the both lower parts of panel
CAUTION: After removing the pipe
front, you can hear sound this panel came out, In hole, cut the burr for safety.
this time panel front is separated
• After pull down this panel a bit, and separate con-
necting wire with product.

Pipe hole

NOTE: When connecting pipe path through rear


wall, don’t remove the hole.

3) Drain hose junction


• Remove the rubber stopple of desired drain direc-
tion.
• As the following picture, Insert drain hose in the han-
dle of drain pan, and join drain hose and connecting
hose.

Panel Front
Connector

Copyright ©2007 LG Electronics. Inc. All right reserved. - 38 -


LGE Internal Use Only
Only for training and service purposes
Installation

■ Sticking the installation guide map and


fixing Indoor unit
1. Put an Installation Guide Map on the desired 7. Drill the piercing part for connecting pipe as
surface. diameter 50mm. (In case of piercing rear surface)
INSTALLATION GUIDE MAP

Refer to No. 5 on this page when making a hole in the wall.

2. Make a hole with diameter of 6mm and depth of 8. First, Drive the two points of the upper parts by
30-35mm when piercing a screw point. screws. (Leave 10mm for hanging product)
IN
ST
AII
AT
IO
N
GU
ID
EM
IN
AP

10
mm ST
AL
LA
TIO
N
3. Drive the fore plastic anchors into drilled points.
GU
IN
ST
AL
LA
TIO
N
9. Drive the lower parts after facing the hole of
GU
ID
EM product with plastic anchors, and fix completely
AP
the upper screws.

Plastic anchors
Plastic anchors

4. Hang the hole of product at the upper screws.


(In this time, Remove the map) In case of nothing wrong in the matter,
INS
(Falling attention) TAL
LAT
ION
GUID connect the pipe and the wire.
EM
AP (Installation manual reference)

Hanger hole
(Rear side of
product)

5. Check the fixed product with light power. ■ Drill a hole in the wall
• Drill the piping hole with a ø50mm hole core drill. Drill
the piping hole at either the right or the left with the hole
slightly slanted to the outdoor side.

WALL
Indoor Outdoor
6. Look at suited horizon by horizontal meter on
the horizontal setting line, and Fix lightly the
map by adhesive tape. IN
ST
(0.2~0.3")

AL
LA
Horizontality TIO
5-7mm

N
GU
ID
EM
AP

Copyright ©2007 LG Electronics. Inc. All right reserved. - 39 -


LGE Internal Use Only
Only for training and service purposes
Installation

3. Art Cool Deluxe Type Indoor Unit 3). Drill a hole in the wall

The wall you select should be strong and solid enough • Drill the piping hole with a ø70mm hole core drill. Drill
to prevent vibration the piping hole at either the right or the left with the
hole slightly slanted to the outdoor side.
1) Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts. WALL
• Mount the installation plate horizontally by aligning Indoor Outdoor
the centerline using a level.
Installation Plate

(3/16"~5/16")
5-7mm
Type "A" screw

2) Measure the wall and mark the centerline. It is


also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
(SU)
C
Installation plate
D

Ø70mm
A
Ø70mm

Left rear piping Right rear piping

(SZ)

Installation plate
D

C A
Left rear piping Right rear piping

CHASSIS Distance (mm)


(Grade) A B C D
SU
92 44 67 44
(9k, 12k)
SZ
35 33 156 33
(7k)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 40 -


LGE Internal Use Only
Only for training and service purposes
Installation

4. Duct Type Indoor Unit


- BH chassis A
Install the unit above the ceiling correctly. B

CASE 1
POSITION OF SUSPENSION BOLT

C
E
• Apply a joint-canvas between the unit and duct to
absorb unnecessary vibration.

D
• Apply a filter Accessory at air return hole.
(G)

F
(Unit:mm)
Dimension
Capacity A B C D E F (G) H I
18k, 24k 932 880 355 45.5 450 30 87 750 163
30k, 36k 1232 1180 355 45.5 450 30 87 830 186

1-3 mm
I
H
• Install the unit leaning to a drainage hole side as a
figure for easy water drainage. Drainage hole

CASE 2
M10 Nut X4
POSITION OF CONSOLE BOLT (Local
M10 SP. washer X 4 supply)
• A place where the unit will be leveled and that can
support the weight of the unit. M10 washer X4
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.

NOTE: M10 washer X4


• Throughly study the following installation locations: (Local
M10 SP. washer X 4 supply)
1. In such places as restaurants and kitchens, considerable
M10 Nut X4
amount of oil steam and flour adhere to the fan, the fin of
the heat exchanger, resulting in heat exchange reduction,
spraying, dispersing of water drops, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting
hood on a cooking table has sufficient capacity so that
it draws oily steam which should not flow into the suc-
tion of the air conditioner.
• Make enough distance from a cooking room to install
the air conditioner in such a place where it may not
suck in oil steam.
2. Avoid installing air conditioner in such circumstances
where cutting oil mist or iron powder is in suspension in
factories, etc.
3. Avoid places where inflammable gas is generated, flows
in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas
is generated.
5. Avoid places near high frequency generators.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 41 -


LGE Internal Use Only
Only for training and service purposes
Installation

- BT chassis
Install the unit above the ceiling correctly. A

CASE 1 B

POSITION OF SUSPENSION BOLT

• Apply a joint-canvas between the unit and duct to

C
E
absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.

D
(Unit:mm)
Dimension
A B C D E F G H
Capacity
9/12K 708 678 434 51 537 455 230 172

18K 1060 1030 434 51 535 805 230 175

1-3 mm
G
H
• Install the unit leaning to a drainage hole side as a
figure for easy water drainage.
F
Drainage hole

CASE 2 M10 Nut X4


(Local
POSITION OF CONSOLE BOLT M10 SP. washer X 4 supply)
M10 washer X4

• A place where the unit will be leveled and that can


support the weight of the unit.
• A place where the unit can withstand its vibration. M10 washer X4
• A place where service can be easily performed. (Local
M10 SP. washer X 4 supply)
M10 Nut X4

Copyright ©2007 LG Electronics. Inc. All right reserved. - 42 -


LGE Internal Use Only
Only for training and service purposes
Installation

C
- BP chassis A

Install the unit above the ceiling correctly.

CASE 1

G
POSITION OF SUSPENSION BOLT

D
E
• Apply a joint-canvas between the unit and duct to
absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
(Unit:mm)
Dimension

F
A B C D E F G H I J K
Capacity B

9k/12k BTU/h 633 580 695 660 750 45 369 797 20 232 372

1-3 mm
I
• Install the unit leaning to a drainage hole side as a
figure for easy water drainage.

H
Drainage hole

CASE 2
M10 Nut X4
(Local
POSITION OF CONSOLE BOLT M10 SP. washer X 4 supply)
M10 washer X4
• A place where the unit will be leveled and that can
support the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed. M10 washer X4
(Local
M10 SP. washer X 4 supply)
M10 Nut X4

Copyright ©2007 LG Electronics. Inc. All right reserved. - 43 -


LGE Internal Use Only
Only for training and service purposes
Installation

- B1, B2 Chassis
Installation of Unit
Install the unit above the ceiling correctly.
B
CASE 1 A

POSITION OF SUSPENSION BOLT

• Apply a joint-canvas between the unit and duct to absorb

D
C
unnecessary vibration.
• Apply a filter Accessory at air return hole.

E
G
(Unit:mm)
Dimension
A B C D E F G H I
Capacity

9/12k BTU/h 850 900 383 570 93.5 190 20.6 795 163
18/24k BTU/h 1130 1180 383 570 93.5 190 20.6 1065 163

F
I
1/100
H

Drainage hole

CASE 2
• Install the unit leaning to a drainage hole side as a figure
for easy water drainage. M10 Nut X4
(Local
M10 SP. washer X 4 supply)
M10 washer X4
POSITION OF CONSOLE BOLT

• A place where the unit will be leveled and that can support
the weight of the unit. M10 washer X4
(Local
• A place where the unit can withstand its vibration. M10 SP. washer X 4 supply)
M10 Nut X4
• A place where service can be easily performed.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 44 -


LGE Internal Use Only
Only for training and service purposes
Installation

Piping and Drainage of Indoor Unit

1. Preparation of pipings Pipe cutter


1) Cut the pipes and the cable.
• Use the accessory piping kit or the pipes pur-
chased locally.
90 Slanted Rough
• Measure the distance between the indoor and
the outdoor unit.
• Cut the pipes a little longer than the measured
distance.
• Cut the cable 1.5m longer than the length of the
pipe.

Pipe
2) Remove burrs.
Reamer
• Remove burrs from cut edges of pipes.
• Turn the pipe end toward down to avoid the
metal powder entering the pipe.

CAUTION: If burrs are not removed, Point down


they may cause a gas leakage.

"A": ø15.88 mm (5/8") → 0~1.0 mm


ø12.7 mm (1/2") → 0~0.5 mm
3) Flaring the pipes. ø9.52 mm (3/8") → 0~0.5 mm
• Insert the flare nuts, mounted on the connection ø6.35 mm (1/4") → 0~0.5 mm
ports of both indoor and outdoor unit, onto the Handle
copper pipes. Some refrgerant gas may leak, Bar
Yoke
when the flare nuts are removed from the indoor
"A"

unit, as some gas is charged to prevent the Bar


Cone
inside of the pipe from rusting.
• Fit the copper pipe end into the Bar of flare tool
about 0~0.5mm higher. (See illustration)
Copper pipe Clamp handle Red arrow mark
• Flare the pipe ends.

4) Tape the flaring portion to protect it from the = Improper flaring =


dust or damages.

Inclined Surface Cracked Uneven


damaged thickness

When properly flared, the internal surface flare will


evenly shine and be of even thickness.
Since the flare part comes into contact with the connec-
tors, carefully check the flare finish.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 45 -


LGE Internal Use Only
Only for training and service purposes
Installation

Connection of indoor unit piping

1. Split Type Indoor Unit 3. Tape the tubing, drain hose and the connecting
cable. Be sure that the drain hose is located at the
• Preparing the indoor unit's piping and drain hose lowest side of the bundle. Locating at the upper side
for installation through the wall. can cause drain pan to overflow inside the unit.
• Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away
from chassis.
• Replace the plastic tubing holder in the original
position.

Loop

Connecting Gas side


cable piping
Tubing holder Liquid side
Drain hose piping
To remove the holder,
press the bottom of NOTE: If the drain hose is routed inside the room,
chassis near the holder 2 Pull insulate the hose with an insulation material* so that
upward and pull the tab dripping from "sweating"(condensation) will not
out of its hole. 1 Press
damage furniture or floors.
*Foamed polyethylene or equivalent is recommended.

CAUTION 4. Indoor unit installation


When install, make sure that the • Hook the indoor unit onto the upper portion of the
remaining parts must be removed installation plate.(Engage the two hooks of the
clearly so as not to damage the rear top of the indoor unit with the upper edge of
piping and drain hose, especially the installation plate.) Ensure that the hooks are
power cord and connecting cable. properly seated on the installation plate by moving
it left and right.

For left rear piping Connecting


cable
1. Route the indoor tubing and the drain hose in the
direction of rear left.
Drain hose
Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).
5. Connecting the pipings to the indoor unit and
drain hose to drain pipe.
• Align the center of the pipings and sufficiently
Drain hose tighten the flare nut by hand.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later. Indoor unit tubing Flare nut Pipings

Copyright ©2007 LG Electronics. Inc. All right reserved. - 46 -


LGE Internal Use Only
Only for training and service purposes
Installation

• When extending the drain hose at the indoor unit,


install the drain pipe.
For right rear piping

1. Route the indoor tubing and the drain hose to the


required piping hole position.
Drain pipe

Indoor unit
drain hose
Vinyl tape(narrow)
Adhesive

6. Wrap the insulation material around the connect-


ing portion. 2. Insert the piping, drain hose and the connecting
• Overlap the connection pipe insulation material cable into the piping hole.
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
Connecting cable
Plastic bands Drain pipe
Insulation material

3. Insert the connecting cable into the indoor unit.


• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
• Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape. 4. Tape the drain hose and the connecting cable.
• Connecting cable
Connection Indoor
pipe unit pipe
Vinyl tape Wrap with vinyl tape
(wide)
Connecting cable

Pipe

Vinyl tape(narrow)
5. Indoor unit installation
• Bundle the piping and drain hose together by • Hang the indoor unit from the hooks at the top of
wrapping them with vinyl tape over the range with- the installation plate.
in which they fit into the rear piping housing sec- • Insert the spacer etc. between the indoor unit and
tion. the installation plate and separate the bottom of
the indoor unit from the wall.
Wrap with vinyl tape

Pipe

Vinyl tape(wide)
Drain hose

Copyright ©2007 LG Electronics. Inc. All right reserved. - 47 -


LGE Internal Use Only
Only for training and service purposes
Installation

6) Connecting the pipings to the indoor unit and the 8) Reroute the pipings and the drain hose across the
drain hose to drain pipe. back of the chassis.
• Align the center of the pipings and sufficiently
tighten the flare nut by hand.

Indoor unit tubing Flare nut Pipings


• When extending the drain hose at the indoor unit, Piping for
install the drain pipe. passage through
piping hole
9) Set the pipings and the drain hose to the back of
Drain hose the chassis with the tubing holder.
• Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
Indoor unit drain hose engaged at the bottom of chassis.
Vinyl tape (narrow)
Adhesive
7) Wrap the insulation material around the connect-
ing portion.
• Overlap the connection pipe heat insulation and
the indoor unit pipe heat insulation material. Bind
them together with vinyl tape so that there is no
gap. Tubing holder
Plastic bands
Insulation material
1 Hook

2 Push

• Wrap the area which accommodates the rear pip-


ing housing section with vinyl tape. 10) Indoor unit installation

Connection
• Remove the spacer.
Indoor
pipe unit piping • Ensure that the hooks are properly seated on the
Vinyl tape installation plate by moving it left and right.
Wrap with vinyl tape
(wide)

Pipe
Connecting
Vinyl tape
cable
Connecting (narrow)
cable
Drain hose
• Bundle the piping and drain hose together by
wrapping them with cloth tape over the range with-
in which they fit into the rear piping housing sec- Press the lower left and right sides of the unit
tion. Pipe against the installation plate until the hooks engage
Drain hose into their slots(clicking sound).
Vinyl tape
(narrow)

Wrap with
vinyl tape(wide)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 48 -


LGE Internal Use Only
Only for training and service purposes
Installation

2. Art Cool Type Indoor Unit • When extending the drain hose at the indoor unit,
install the drain pipe.
• Preparing the indoor unit's piping and drain hose for
installation through the wall.
1) Route the indoor tubing and the drain hose in the
direction of rear left or right. Drain pipe

2) Tape the tubing, drain hose, and the connecting


cable. Be sure that the drain hose is located at the Indoor unit drain hose
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the Vinyl tape(narrow)
Adhesive
unit.
4) Wrap the insulation material around the connecting
portion.
• Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there is no gap.

Plastic bands Insulation material


Loop

Gas side piping


Connecting
cable
Liquid side piping
Drain hose
• Wrap the area which accommodates the rear piping
housing section with vinyl tape.
NOTE: If the drain hose is routed inside the room,
insulate the hose with an insulation material* so that
dripping from "sweating"(condensation) will not damage
Connection Indoor
furniture or floors. pipe unit pipe
*Foamed polyethylene or equivalent is recommended.
Vinyl tape Wrap with vinyl tape
(wide)

3) Connecting the pipings to the indoor unit and drain


Connecting cable
hose to drain pipe.
• Align the center of the pipes and sufficiently tighten
the flare nut by hand. Pipe

Vinyl tape(narrow)

Indoor unit tubing Flare nut Pipes • Bundle the piping and drain hose together by wrap-
ping them with vinyl tape for enough to cover where
• Tighten the flare nut with a wrench. they fit into the rear piping housing section.

Wrap with vinyl tape


Open-end wrench (fixed)
Pipe
Flare nut
Connection pipe
Wrench
Vinyl tape(wide)
Drain hose
Indoor unit tubing

Copyright ©2007 LG Electronics. Inc. All right reserved. - 49 -


LGE Internal Use Only
Only for training and service purposes
Installation

■ Panel Assembly
1. First, Check the side cover assembly exactly, Fix
power cord in the bottom groove of cover side
left.

2. Assemble connecting lead wire with controller


and first fix the upper part of panel front, then
match the lower part of panel front

Panel Front
Connector

3. Drive two screws.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 50 -


LGE Internal Use Only
Only for training and service purposes
Installation

3. Art Cool Deluxe Type Indoor Unit NOTE: If the drain hose is routed inside the room,
insulate the hose with an insulation material* so that
Connection of piping Indoor
dripping from "sweating"(condensation) will not damage
• Preparing the indoor unit's piping and drain hose for furniture or floors.
installation through the wall. *Foamed polyethylene or equivalent is recommended.
• Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from 4. Indoor unit installation
chassis. • Hook the indoor unit onto the upper portion of the
• Replace the plastic tubing holder in the original position. installation plate.(Engage the two hooks of the rear
(Optional) top of the indoor unit with the upper edge of the instal-
lation plate.) Ensure that the hooks are properly seat-
ed on the installation plate by moving it left and right.

Connecting
cable

Drain hose

Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
For right rear piping
4. Connecting the pipings to the indoor unit and drain
1. Route the indoor tubing and the drain hose in the hose to drain pipe.
direction of rear right. • Align the center of the pipes and sufficiently tighten
the flare nut by hand.

Drain hose
Indoor unit tubing Flare nut Pipes
• Tighten the flare nut with a wrench.

2. Insert the connecting cable into the indoor unit Open-end wrench (fixed)

from the outdoor unit through the piping hole.


• Do not connect the cable to the indoor unit. Flare nut
• Make a small loop with the cable for easy Connection pipe
Wrench
connection later.
3. Tape the tubing, drain hose, and the connecting Indoor unit tubing
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper Outside diameter Torque
side can cause drain pan to overflow inside the mm inch kg.m
unit. Ø6.35 1/4 1.8
Ø9.52 3/8 4.2
Ø12.7 1/2 5.5
• When extending the drain hose at the indoor unit,
install the drain pipe.

Tape
Connecting
pipe

Drain hose
Connecting cable

Copyright ©2007 LG Electronics. Inc. All right reserved. - 51 -


LGE Internal Use Only
Only for training and service purposes
Installation

5. Wrap the insulation material around the connecting 4. Tape the drain hose and the connecting cable.
portion. • Connecting cable
• Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there is no gap.
Plastic bands Insulation material

5. Indoor unit installation


• Hang the indoor unit from the hooks at the top of the
installation plate.
• Wrap the area which accommodates the rear piping
• Insert the spacer etc. between the indoor unit and the
housing section with vinyl tape.
Indoor
installation plate and separate the bottom of the
Connection
pipe unit pipe indoor unit from the wall.
Vinyl tape Wrap with vinyl tape
(wide)
Connecting cable Indoor unit
Spacer
Pipe
Installation plate
Vinyl tape(narrow)
8cm
• Bundle the piping and drain hose together by wrap-
6. Connecting the pipings to the indoor unit and the
ping them with vinyl tape for enough to cover where
drain hose to drain pipe.
they fit into the rear piping housing section.
• Align the center of the pipes and sufficiently tighten
Wrap with vinyl tape
the flare nut by hand.
Pipe

Vinyl tape(wide) Indoor unit tubing Flare nut Pipes


Drain hose
• Tighten the flare nut with a wrench.
For left rear piping
Open-end wrench (fixed)
1. Route the indoor tubing and the drain hose to the
required piping hole
Flare nut
position.
Connection pipe
Wrench

Indoor unit tubing

Outside diameter Torque


mm inch kg.m
Ø6.35 1/4 1.8
2. Insert the piping, drain hose, and the connecting
Ø9.52 3/8 4.2
cable into the piping hole.
Ø12.7 1/2 5.5
• When extending the drain hose at the indoor unit,
Connecting cable install the drain pipe.
Drain pipe
Drain hose

3. Insert the connecting cable into the indoor unit.


Indoor unit drain hose
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy connection later. Adhesive
Vinyl tape (narrow)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 52 -


LGE Internal Use Only
Only for training and service purposes
Installation

7. Wrap the insulation material around the con- 9. Set the pipings and the drain hose to the back of
necting portion. the chassis with the tubing holder.
• Overlap the connection pipe heat insulation and the • Hook the edge of tubing holder to tap on chassis and
indoor unit pipe heat insulation material. Bind them push the bottom of tubing holder to be engaged at the
together with vinyl tape so that there is no gap. bottom of chassis.

Plastic bands Insulation material

Tubing holder
• Wrap the area which accommodates the rear piping
housing section with vinyl tape.

Connection Indoor
unit piping 10. Indoor unit installation
pipe
• Remove the spacer.
Vinyl tape Wrap with vinyl tape
(wide) • Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Pipe

Vinyl tape(narrow)
Connecting cable
Connecting
cable

Drain hose
• Bundle the piping and drain hose together by wrap-
ping them with cloth tape over the range within which
Press the lower left and right sides of the unit against
they fit into the rear piping housing section.
the installation plate until the hooks engage into their
Pipe slots(clicking sound).
Drain hose
Vinyl tape(narrow)

Wrap with
vinyl tape(wide)

8. Reroute the pipings and the drain hose across the


back of the chassis.

Piping for
passage through
piping hole

Copyright ©2007 LG Electronics. Inc. All right reserved. - 53 -


LGE Internal Use Only
Only for training and service purposes
Installation

CAUTION

• Bad case
Installation Information (For left piping) ■ Following bending type from right to left could cause problem
• Good case of pipe damage.
For left piping. Follow the instruction below.
• Press on the upper side of clamp. ( )

• Bend the tubing to the left side of chassis.

• Bend the tubing to the left side of chassis.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 54 -


LGE Internal Use Only
Only for training and service purposes
Installation

4. Duct Type Indoor Unit


1) Indoor Unit Installation
• Select and mark the position for fixing bolts.
• Drill the hole for set anchor on the face of ceiling.

Old building New building

• Insert the set anchor and washer onto the suspen-


sion bolts for locking the suspension bolts on the ceil-
ing.
• Mount the suspension bolts to the set anchor firmly. 1 Set anchor
• Secure the installation plates onto the suspension 2 Plate washer
bolts (adjust level roughly) using nuts, washers and
3 Spring washer
spring washers.
4 Nut
5 Suspension
CAUTION: Tighten the nut and bolt to bolts
prevent unit falling.
• Local supply
➀ Set anchor
➁ Plate washer - M10
➂ Spring washer - M10
➃ Nut - W3/8 or M10
➄ Suspension bolt - W3/8 or M10

Copyright ©2007 LG Electronics. Inc. All right reserved. - 55 -


LGE Internal Use Only
Only for training and service purposes
Installation

5. CVT Type Indoor Unit


- VB chassis
■ Before Installing, prepare Installation Plates Side Plate
• 'Installation Plates' are attached at the bottom of R

indoor unit.
Detach them by removing each 3 screws at both
sides.
• Detach 'Side Plate (R,L)' by removing each 2 screws Install Plate
on both sides.
• Pull the upper right and left side of 'Inlet Grille' to the
front, and it will stop at slightly tilted position.
• Unhook the 'Inlet hanger' from the 'Hanger screw' on
the both left and right side.
• Detach the 'Inlet Grille' from the Indoor Unit. Inlet hanger

1) Installation on the ceiling


R

• Measure and mark the position for the


Suspension bolts and the piping hole. Hanger
• Drill the hole for anchor nut on the ceiling. Inlet Grille screw

1) 1076 265

Suspension
Before secure the Installation Plates, select the bent bolt
Center-line for the
direction of the Installion Plate to the inside or the piping hole
outside according to the installation circumstances.
2) 1236 265

• Drill the piping hole on the wall slightly tilted to the


outdoor side using a ø70 hole-core drill.

Indoor WALL Outdoor

5~7mm

Copyright ©2007 LG Electronics. Inc. All right reserved. - 56 -


LGE Internal Use Only
Only for training and service purposes
Installation

• Insert the nuts and washer onto the suspension bolts 1)


Anchor nut

for locking the suspension bolts on the ceiling. Ceiling


• Mount the suspension bolts to the anchor-nuts firmly.
• Secure the Installation plates onto the Suspension Nut Washer

bolts (adjust level roughly.) using nuts, washers and Suspension


bolts
spring washers.
Suspension
bolts

Spring
washer Nut

max.
12mm Washer

2)

• Engage 2 hooks on the both left and right side


of the unit to the lower slot of Installation Plates.
• Adjust a level with a level gauge on the direction Lower slot
of left-right, back-forth by adjusting suspension Level gauge
bolts.
• Move the hooks on the unit to the upper slot of R

Installation Plates. Then the unit will be declined


to the bottomside so as to drain well.

Suspension Adjust a level


bolt

Installation plate

Upper slot

Copyright ©2007 LG Electronics. Inc. All right reserved. - 57 -


LGE Internal Use Only
Only for training and service purposes
Installation

- VE chassis
The wall you select should be strong and solid
enough to prevent vibration Installation Plate
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
Type "A" screw

2. Measure the wall and mark the centerline. It is


also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi- 70 70
Installation plate
cally. Drilling the hole through the wall for piping
connections must be done safely. 120
Ø70mm Ø70mm
Left rear piping more than 200 Right rear piping

Floor

Mounting the anchor Nut & Bolt


(Ceiling Mounting)
• Prepare 4 suspension bolts (Each bolts length
should be same.)
• Measure and mark the position for the Suspension
bolts and the piping hole.
• Insert the nuts and washer onto the suspension
bolts for locking the suspension bolts on the ceil-
ing.
• Mount the suspension bolts to the anchor-nuts
firmly.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 58 -


LGE Internal Use Only
Only for training and service purposes
Installation

• Secure the Installation plates onto the Suspension


bolts (adjust level roughly.) using nuts, washers and Anchor nut

spring washers. Ceiling

• Engage 2 hooks on the both left and right side of the Nut Washer
235
820
unit to the lower slot of Installation Plates. Suspension
bolts

• Adjust a level with a level gauge on the direction of Suspension bolt


left-right, back-forth by adjusting suspension bolts.
• Move the hooks on the unit to the upper slot of
Installation Plates. Then the unit will be declined to
the bottomside so as to drain well. Center-line for the
piping hole

Suspension
bolts

Spring
washer Nut
Hangen

Max.
12mm Washer

Drill a Hole in the Wall


• Drill the piping hole with a ø70mm hole core drill. WALL
Drill the piping hole at either the right or the left with Indoor Outdoor
the hole slightly slanted to the outdoor side.
(3/16"~5/16")
5-7mm

Copyright ©2007 LG Electronics. Inc. All right reserved. - 59 -


LGE Internal Use Only
Only for training and service purposes
Installation

CAUTION: Installation Information For Declination


CAUTION

1. Install declination of the indoor unit is very important for the drain of the convertible type air
conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 7mm.
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined
to the bottomside.

Front of view

• The unit must be horizontal or declined to the drain hose connected when finished installation.

Ceiling

Drain hose

Ceiling

Side of view

• The unit must be declined to the bottomside of the unit when finished installation.

Ceiling

Copyright ©2007 LG Electronics. Inc. All right reserved. - 60 -


LGE Internal Use Only
Only for training and service purposes
Installation

• Secure the unit to the Installation Plates with four M8


bolts and washers.

• Before working, refer to "Connecting pipe


and cable to Indoor Unit".
• Hook up the Inlet Grille Hook to the cabinet.
Inlet hanger
• Hang the Inlet Hanger to the screw.

Hook
Cabinet Bottom

• Fit the projection hooks of the side plates to the 'Side


Panel' and the 'Front Panel' by lifting it.
• Fasten the screws.

R
2

Copyright ©2007 LG Electronics. Inc. All right reserved. - 61 -


LGE Internal Use Only
Only for training and service purposes
Installation

2) Installation on the Wall


• Select and mark the position for fixing bolts and piping
hole. 1076
Decide the position for fixing bolts slightly tilted to the mor
e th
drain direction after considering the direction of drain 260 an
hose.
• Drill the hole for anchor nut on the wall.

265

• Drill the piping hole on the wall slightly tilted to the out-
door side using a ø70 hole-core drill.
Wall
Indoor Outdoor

5~7mm
• Secure the 'Install Plate' onto the wall with four anchor
bolts, washers and spring washers.
Spring
washer Wall

Nut

Washer
Anchor nut

Less than
12mm

Before secure the Install Plates, select the bent direc-


tion of the 'Install Plate' to the inside or outside accord-
ing to the installation circumstances. 123
6

Copyright ©2007 LG Electronics. Inc. All right reserved. - 62 -


LGE Internal Use Only
Only for training and service purposes
Installation

Install the Indoor unit onto Installation Plate.


• Insert 2 hooks on the both left and right side of the unit
Inner slot
to the inner slot (wall side) of the Installation Plate.

• Secure the unit to the Installation Plate with four M8


bolts and washers. R

• Before working, refer to "Connecting pipe


and cable to Indoor Unit".
• Hook up the Inlet Grille Hook to the cabinet.
• Hang the Inlet Hanger to the screw.

• Fit the projection hooks of the side plates to the 'Side


Panel' and the 'Front Panel' by lifting it.
• Fasten the screws.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 63 -


LGE Internal Use Only
Only for training and service purposes
Installation

3) Installation on the floor


From the left wall
Installation of Mount Bracket. more than 760mm
• Select and mark the position for Mount Brackets and
the piping hole.
• Drill the hole for the anchor nut on the wall. From the
• Drill the piping hole using a ø70 hole-core drill. right wall
• Secure the Mount Brackets on the wall with four M4 more than 840mm
screws.

Install the indoor unit onto the Mount Brackets.


• Engage the slot at the back of the unit with Mount
Bracket. Slot

448mm
Floor mount
bracket

• Drill the piping hole with 70mm dia, hole core drill.
• Piping hole should be slightly slant to the outdoor side.
Wall
Indoor Outdoor

After Installing, reassemble detached parts. 5~7mm


• Hang the 'Inlet Grille' and hook the 'Inlet Hanger' to the
Hanger Screw. Slot
• Assemble the 'Side Plates(R,L)' with 2 screws on both Wall
left and right side.

Floor mount
bracket
Install plate

Piping hole

Copyright ©2007 LG Electronics. Inc. All right reserved. - 64 -


LGE Internal Use Only
Only for training and service purposes
Installation
6. Ceiling Cassette Type Indoor Unit
- TC, TC1 chassis
1) Ceiling opening dimensions and hanging bolt location
• The dimensions of the paper model for installing are
the same as those of the ceiling opening dimen- 1,000 (Ceiling opening)
sions. 931.6
893.4 (Hanging bolt)
860

Ceiling

328.4 (Hanging bolt) 30.8


430 (Ceiling opening)
390
Level gauge

CAUTION
• This air-conditioner uses a drain pump.
• Install the unit horizontally using a level gauge.
• During the installation, care should be taken not to
damage electric wires.

• Select and mark the position for fixing bolts and pip-
ing hole. Ceiling board
• Decide the position for fixing bolts slightly tilted to
the drain direction after considering the direction of
drain hose.
• Drill the hole for anchor bolt on the wall.

NOTE:
• Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
• Make sure that ventilation fan is enough to cover all noxious gases from this place.
• Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 65 -


LGE Internal Use Only
Only for training and service purposes
Installation

2) Indoor Unit Installation

Ceiling

103mm
Hanging bolt Keep the length of the bolt
(W3/8 or M10) from the bracket to 40mm
Nut
Flat washer for M10
(W3/8 or M10)
(accessory) Ceiling board Air Conditioner body Ceiling board
Spring washer
(M10)

Flat washer for M10


(accessory) Paper model Set screw of
Nut for installation paper model (4 pieces)
(W3/8 or M10)

Adjust the same height Open the ceiling board


along the outer edge of the
paper model

• The following parts are local purchasing. • Drill the piping hole on the wall slightly tilted to the
Hanging Bolt - W 3/8 or M10 outdoor side using a Ø 70 hole-core drill.
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10 Wall
Indoor Outdoor
CAUTION
• Tighten the nut and bolt to prevent unit from
falling off.

5~7mm

Copyright ©2007 LG Electronics. Inc. All right reserved. - 66 -


LGE Internal Use Only
Only for training and service purposes
Installation
7. Ceiling Cassette Type Indoor Unit
- TE(1)/TF/TH/TD chassis
1) Ceiling opening dimensions and hanging bolt location

• The dimensions of cardboard for installing are the 600 (Ceiling opening) TE(1)
same as those of the ceiling opening dimensions. 39.5 521(Hanging bolt) 39.5

75
600 (Ceiling opening)
Ceiling

450 (Hanging bolt)


570 Unit size

570 Unit size


Level gauge

75
CAUTION Unit:mm
• This air-conditioner uses a drain pump.
• Install the unit horizontally using a level gauge. 790 (Ceiling opening)
TF
• During the installation, be careful not to damage 572(Hanging bolt)
109 109
electric wires.

66
790 (Ceiling opening)
658 (Hanging bolt)
• Select and mark the position for fixing bolts and piping hole.
744 Unit size
• Decide the position for fixing bolts slightly tilted to the drain
744 Unit size
direction after considering the direction of drain hose.
• Drill the hole for anchor bolt on the wall.

66
Unit:mm

Ceiling board
875 (Ceiling opening)
TH/TD
45 785 (Hanging bolt) 45
101.5 672 (Hanging bolt) 101.5
875 (Ceiling opening)

840 Unit size


840 Unit size

Unit:mm

Copyright ©2007 LG Electronics. Inc. All right reserved. - 67 -


LGE Internal Use Only
Only for training and service purposes
Installation

NOTE:
• Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
• Make sure that ventilation fan is enough to cover all noxious gases from this place.
• Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

2) The Indoor Unit Installation


Ceiling

Hanging bolt Keep the length of the bolt

150mm
(W3/8 or M10) from the bracket to 40mm
Nut
Flat washer for M10 Air Conditioner body
(W3/8 or M10)
(accessory) Ceiling board Ceiling board
Spring washer
(M10)

Flat washer for M10


(accessory) Cardboard Set screw of
Nut for installation cardboard (4 pieces)
(W3/8 or M10)

Adjust the same height Open the ceiling board


along the outer edge of the
paper model

• The following parts are local purchasing. • Drill the piping hole on the wall slightly tilted to the
Hanging Bolt - W 3/8 or M10 outdoor side using a Ø 70 hole-core drill.
Nut - W 3/8 or M10
Spring Washer - M10 Wall
Plate Washer - M10 Indoor Outdoor

CAUTION
• Tighten the nut and bolt to prevent the unit from
5~7mm

falling off.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 68 -


LGE Internal Use Only
Only for training and service purposes
Installation

Remote Controller Installation


• Although the room temperature sensor is in the indoor unit, the remote controller should be installed
in such places away from direct sunlight and high humidity.
Installation of the remote controller
• Select places that are not splashed with water.
• Select control position after receiving customer approval.
• The room temperature sensor is built in the indoor unit.
• This remote controller equipped with liquid crystal display. If this position is higher or lower, display is difficult
to see.(The standard height is 1.2 ~ 1.5m high)
Routing of the remote controller cord
• Keep the remote controller cord away from the refrigerant piping and the drain piping.
• To protect the remote controller cord from electrical noise, place the cord at least 5cm away from other power
cables (audio equipment, television set, etc.)
• If the remote controller cord is secured to the wall, provide a trap at the top of the cord to prevent water
droplets from running.

WIRED REMOTE CONTROL INSTALLATION


DISASSEMBLING
Front case • Separate the under plate from Remote control box.

Th
el
ow
er
pa
rt

Lever carefully Remote control


the box open box body
using a screw • Fix the cord clamps on the wall by ø 3 tapping
driver, etc.
screws (accessory).
• Fix the under plate on the wall • Fix the remote control cord.

Face of wall
Cord clamp
Under plate
(accessory)

Screw (accessory)

ELECTRICAL WIRING Remote controller


(Main board)
CN REMO

Wire and make sure that teminal


numbers are matched on unit side and
remote controller side.
The maximum length of the cord is 100m.
If the length of the cord exceeds 50m,
2
use a wire size greater than 0.5mm .

Copyright ©2007 LG Electronics. Inc. All right reserved. - 69 -


LGE Internal Use Only
Only for training and service purposes
Installation

REMOTE CONTROL PREPARATION(OPTIONAL)


HOW TO MOUNT ONTO A WALL

HOW TO INSERT BATTERIES


Remove the battery cover from the remote con-
troller.
• Slide the cover according to the arrow direction. • Do not use rechargeable batteries,
such batteries differ from standard dry
Insert the two batteries. cells in shape, dimensions, and per-
• Be sure that the (+) and (-) directions are correct. formance.
• Be sure that both batteries are new. • Romove the batteries from the remote
controller if the air conditioner is not
Re-attach the cover. going to be used for some long time.
• Slide it back into position.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 70 -


LGE Internal Use Only
Only for training and service purposes
Installation

Connecting Pipings and the cable to Outdoor unit


1. Connecting the pipings to the Outdoor 3) Finally, tighten the flare nut with torque wrench until
the wrench clicks.
unit ■ When tightening the flare nut with torque wrench,
1) When piping installation work you must be used the ensure the direction for tightening follows the arrow on
connector. the wrench.
Gas Outdoor unit A-UNIT
Indoor Units Liquid
A→B
Gas side piping
18K/24K Ø9.52→Ø12.7 Not available
30K/36K Ø9.52 →Ø15.88 Not available B-UNIT
Liquid side piping

A B
Torque wrench
*Connecting pipe size

Indoor Units Gas side Liquid side


7K/9K/12K Ø9.52(3/8) Ø6.35(1/4) 4) Distributor type piping (only A4UW306FA1)
1) Connect main piping from outdooor to BD unit using
18K/24K Ø12.7(1/2) Ø6.35(1/4)
socket.
30K/36K Ø15.88(5/8) Ø6.35(1/4) 2) Socket is fitted in BD unit
2) Align the center of the pipings and sufficiently tight- (Socket P/No.: 5001A30059A)
en the flare nut by hand

Connector

CAUTION: After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guided by
the circuit diagram pasted on the inside of control box cover.
2) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air
gap contact separation of at least 3mm in each active(phase) conductors.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations
to which the unit is subjected during the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Specification of power source.
5) Confirm that electrical capacity is sufficient.
6) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the
name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function
of a overload protection device.
• Proper starting power is not given to the compressor.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 71 -


LGE Internal Use Only
Only for training and service purposes
Installation

2. Electric characteristics
Unit Power Compressor OFM
Model Type Hz Voltage Voltage range MCA MOP MSC RLA KW FLA
A2UW146FA0
[FM14AH UE0]
A2UW146FA1
[FM15AH UE1] 7.25 13.05 8 6 0.067 0.68
A2UW146FA2
[FM15AH UL2]
A2UW166FA0
[FM17AH UL0] Inverter
8.00 14.40 8 6 0.067 0.68
A2UW166FA1
[FM17AH UL1]
A2UW186FA0
9.75 17.55 14 7 0.067 0.68
[FM18AH UE0]
A3UW186FA0 MIN.:198
50 220~240 9.75 17.55 14 7 0.067 0.68
[FM19AH UE0] MAX.:264
A3UW246FA0
13.50 24.30 23.1/14.0 6.1/7.0 0.041 0.73
[FM24AH UE0]
A4UW246FA0 MPS
13.50 24.30 23.1/14.0 6.1/7.0 0.041 0.73
[FM25AH UE0] Inverter
A4UW306FA0
15.25 27.45 26.0/14.0 8.1/7.0 0.041*2 0.73*2
[FM30AH UE0]
A6UW406FA0
22.6 39.5 14/63 7.0/14.0 0.12x2 0.73x2
[FM40AH UH0]
A7UW486FA0 MPS
29.3 50.8 14/35/35 7.0/8.0/8.0 0.43 2.43
[FM48AH UY0] inverter
A8UW566FA0
32.7 56.9 14/35/63 7.0/8.0/14.0 0.43 2.43
[FM56AH UY0]

Notes :
1. Voltage range 9. RLA is measured during each individual compressor test
Voltage supplied to the unit terminals should be within the condition.
minimum and maximum range Ex) 6.1/7.0 : RLA of (inv. comp.) / (const. comp.)
2. Maximum allowable voltage unbalance between phase is 2 % 10. OFM is measured as the outdoor unit test condition
3. MCA / MOP (Example) Selection of proper circuit breaker
MCA = (1.25 x Load1) + Load2 + Load3 1 Model : A2UW146FA0 [FM14AH UE0]
MOP = (2.25 x Load1) + Load2 + Load3 - Rated running current : 5.8 A (refer to spec. sheet)
- Load1 : Rated running current of largest motor
2 MCA = (1.25 x Load1) + Load2 + Load3
(compressor or other motor)
- Load2 : sum of current for all other motors = (1.25 x 5.8) + 0 + 0 = 7.25 A
- Load3 : any other load rated 1.0A or more 3 MOP = (2.25 x Load1) + Load2 + Load3
4. Select wire spec. based on the MCA = (2.25 x 5.8) + 0 + 0 = 13.05 A
Finally select circuit breaker 15A
5. Select proper circuit breaker as given below
MCA < Circuit breaker MOP
6. Recommended circuit breaker is ELCB (Earth Leakage circuit MCA : Minimum Circuit Amperes (A)
breaker) MOP : Maximum rating over current protective device
7. MSC & RLA are measured as the compressor only test MSC : Maximum Starting Current
condition. RLA : Rated Load Amperes (A)
8. MSC values OFM : Outdoor Fan Motor
23.1/14.0 : MSC of (inv. comp.) / (const. comp.) kW : Fan Motor rated output (kW)
FLA : Full Load Amperes (A)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 72 -


LGE Internal Use Only
Only for training and service purposes
Installation

CAUTION: If a power plug is not to be used, provide a circuit breaker between


power source and the unit as shown below.
Main power source

Air
Conditioner Circuit Breaker
Use a 30A circuit
breaker or time
delay fuse.

CAUTION
The power cord connected to the outdoor unit The connecting cable connected to the indoor
should be complied with the following specifica- and outdoor unit should be complied with the fol-
tions (Rubber insulation, type H05RN-F approved lowing specifications (Rubber insulation, type
by HAR or SAA). H07RN-F approved by HAR or SAA).
ø8.5mm

ø7.5mm
NORMAL CROSS- NORMAL CROSS-
SECTIONAL AREA SECTIONAL AREA
GN
/YL 3.5mm2 GN
/YL
0.75mm2

20
mm 20
mm

Copyright ©2007 LG Electronics. Inc. All right reserved. - 73 -


LGE Internal Use Only
Only for training and service purposes
Installation

Checking the Drainage and Pipe forming

1. Split Type Indoor Unit


1) Remove the Grille from the cabinet
• Set the up-and-down air direction louver to
open position(horizontally) by finger pressure.
• Remove the securing screws. Screw
• To remove the Grille, pull lower the left and
right side of the grille toward you (slightly tilted) Pull the right and
the left side.
and lift it straight upward.

2) Check the drainage


• Pour a glass of water on the evaporator.
• Ensure if water flows drain hose of indoor unit
without any leakage.

2. Art Cool Type Indoor Unit


• Pour a glass of water on the evaporator.
• Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 74 -


LGE Internal Use Only
Only for training and service purposes
Installation

3. Art Cool Deluxe Type Indoor Unit 3) Drain piping


• The drain hose should point downward for easy drain
1) To remove the front panel from the indoor unit.
flow.
• Set the air direction louvers up-and-down to the posi-
tion(horizontally) by hand.
• Remove the securing screws that retain the front Downward slope
panel. Pull the lower left and right sides of the grille
toward you and lift it off.

• Do not make drain piping.


Air
filter
Do not raise

Inlet Grille
Water
leakage

Accumulated
drain water
2) To check the drainage. Air
• Pour a glass of water on the evaporator.
• Ensure the water flows through the drain hose of the
Water
indoor unit without any leakage and goes out the drain Waving
leakage
exit.

Connecting area
drain hose Tip of drain hose
dipped in water

Water
Leakage leakage Ditch
checking

Less than
50mm gap

Copyright ©2007 LG Electronics. Inc. All right reserved. - 75 -


LGE Internal Use Only
Only for training and service purposes
Installation

4. Convertible Type Indoor Unit


To remove the front panel from the indoor
unit.
1. Set the air direction louvers up-and-down to the posi-
tion(horizontally) by hand.
2. Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the grille
toward you and lift it off. Pull the right and
the left side.

To check the drainage.


1. Pour a glass of water on the evaporator.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.

Drain piping
1. The drain hose should point downward for easy drain
flow. Downward slope

2. Do not make drain piping like the following.

Accumulated
Do not raise
drain water
Tip of drain hose Less than
Air
dipped in water 50mm gap

Water Water Water


Waving
leakage leakage leakage Ditch

Copyright ©2007 LG Electronics. Inc. All right reserved. - 76 -


LGE Internal Use Only
Only for training and service purposes
Installation

5. Duct Type Indoor Unit

1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 5mm.

Front of view

• The unit must be horizontal or declined to the drain hose connected when finished installation.

Ceiling

1~3mm
CORRECT INCORRECT
Drainage hole Drainage hole

CAUTION FOR GRADIENT OF Lay the drain hose with a downware


UNIT AND DRAIN PIPING inclination so water will drain out.
• Always lay the drain with downward inclination Thermal insulator
(1/50 to 1/100). (Local supply)
Prevent any upward flow or reverse flow in any part. Drainage pipe
• 5mm or thicker formed thermal insulator shall (Local supply)
always be provided for the drain pipe. Unit

Make sure to be closed. Drainage hole

• Upward routing not


allowed

700mm
INCORRECT
Applied U-Trap Dimension
(Drain pump model only)
A ≥ 70mm
CORRECT B ≥ 2C
C ≥ 2 x SP
SP = External Pressure B
(mmAq) C
Ex) External Pressure
• Install the P-Trap (or U-Trap) to prevent = 10mmAq U-Trap
A ≥ 70mm A
a water leakage caused by the blocking B ≥ 40mm
of intake air filter. C ≥ 20mm

Copyright ©2007 LG Electronics. Inc. All right reserved. - 77 -


LGE Internal Use Only
Only for training and service purposes
Installation

6. CST Type Indoor Unit


• Drain piping must have down-slope (1/50 to 1/100): Upward
Pipe clamp
routing
be sure not to provide up-and-down slope to prevent not allowed
reversal flow.
• During drain piping connection, be careful not to Indoor unit
exert extra force on the drain port on the indoor
unit.
• The outside diameter of the drain connection on Maintenance
the indoor unit is 32mm. drain port
Piping material: Polyvinyl chloride pipe VP-25
and pipe fittings

• Be sure to install heat insulation on the drain piping. 1/50~1/100

Heat insulation material: Polyethylene foam with MAX 700mm


thickness more than 8 mm.

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

Feed water Flexible drain hose


(accessory) • Connect the main drain pipe to the exterior
and leave it provisionally until the test comes
Main
drain pipe to an end.
• Feed water to the flexible drain hose and
Drain check the piping for leakage.
port Glue the joint • Be sure to check the drain pump for normal
Drain Pump
operating and noise when electrical wiring is
Drain hose connection
Use the clip (accessory) finished.
• When the test is completed, connect the flexi-
ble drain hose to the drain port on the indoor
unit.
Drain pan

Copyright ©2007 LG Electronics. Inc. All right reserved. - 78 -


LGE Internal Use Only
Only for training and service purposes
Installation

Maximum Length of Pipe and Extra Charge of Refrigerant Charge


1. TPS Inverter Multi -Multi Piping Type

1.1 The maximun allowable level and piping length

[Outdoor Unit]

It does not matter which unit is higher.

[Indoor Unit]
A

B
15m

C 7.5m

Model Standard Length Max piping length each indoor unit


[Outdoor Unit] Max total piping length
A,B,C,D A B C D
A2UW146FA0/1/2
7.5m 20m 20m - - 30m(A+B)
A2UW166FA0/1
A2UW186FA0
7.5m 25m 25m - - 40m(A+B)
A3UW186FA0/1
A3UW246FA0 7.5m 25m 25m 25m - 50m(A+B+C)
A4UW246FA0
A4UW24GFA0
A4UW30GFA0 7.5m 25m 25m 25m 25m 70m(A+B+C+D)
A4UW306FA0

1.2 Refrigerant Charge


Indoor Unit Capacity Pipe Size Rated Max Additional
(Btu/h) Gas Liquid Length Length Refrigerant

7k, 9k, 12k 3/8"(9.52mm) 1/4"(6.35mm) 7.5m 25m 25g/m

18k, 24k 1/2"(12.7mm) 1/4"(6.35mm) 7.5m 25m 35g/m

❈ Extra refrigerant = (Extended length - Rated length) x Additional refrigerant

Copyright ©2007 LG Electronics. Inc. All right reserved. - 79 -


LGE Internal Use Only
Only for training and service purposes
Installation

2. TPS Inverter Multi - Distributor Type


2.1 The maximum allowable level and piping length

Outdoor Unit

Installation of the outdoor unit


in an upper position

A Place the BD unit and


indoor units within a
BD Unit level distance of 10m
L1 R from each other.

L2

L3
30m
B BD Unit
L4
10m

L5
Main piping
Branch piping
L6

• Total main piping length : 50m( A + B )


• Total branch piping length : 50m(L1+L2+ L3+L4 +L5+L6)
• Each branch piping length : 15m(L1,L2,L3,L4 ,L5,L6)
• Total system piping length : 100m(40+60)
R

BD Unit

Place the BD unit and


indoor units within a
level distance of 10m
10m from each other.

BD Unit

30m
Outdoor Unit

Installation of the outdoor unit


in a lower position

Copyright ©2007 LG Electronics. Inc. All right reserved. - 80 -


LGE Internal Use Only
Only for training and service purposes
Installation

■ Distributor Type(A4UW306FA1)

Outdoor Unit

Place the BD unit and


indoor units within a
level distance of 7.5m
from each other.
Installation of the outdoor unit
A in an upper position

L1

BD Unit
L2
7.5m
15m
L3
Main piping
Branch piping
L4

• Total main piping length : 15m( A )


• Total branch piping length : 50m(L1+L2+ L3+L4 )
• Each branch piping length : 15m(L1,L2,L3,L4 )
• Total system piping length : 65m(15+50)

R Place the BD unit and


indoor units within a
BD Unit level distance of 7.5m
7.5m from each other.

Outdoor Unit
15m

Installation of the outdoor unit


in a lower position

Copyright ©2007 LG Electronics. Inc. All right reserved. - 81 -


LGE Internal Use Only
Only for training and service purposes
Installation

2.2 Refrigerant charge


The calculation of the additional charge should be taken in account for the length of pipe.

A6UW406FA0 charge = 4100g A4UW306FA1 charge = 2500g


A A7UW486FA0 charge = 7100g
A8UW566FA0 charge = 7100g Additional charge (g)
B Additional charge (g)
= Total Main pipe length - rated length x 40g/m
= Total Main pipe length - rated length x 50g/m
+ 7,9,12 k Branch pipe length - rated length x 20g/m
+ 7,9,12 k Branch pipe length - rated length x 20g/m
+ 18,24 k Branch pipe length - rated length x 30g/m
+ 18,24 k Branch pipe length - rated length x 30g/m

+ 30,36 k Branch pipe length - rated length x 35g/m

- CF(Correction Factor) x 100

• Rated length = 5m,


• CF = Max. number of connectable indoor unit – Total number of connected indoor unit

Total Amount (g) = A + B

✽ Note : If total additional charge value after calculation comes out to be negative, then do not
consider additional charge.
2.3 Refrigerant charge
The calculation of the additional charge should be taken in account for the length of pipe.

• Total main pipe(A+B+C) = 30m


• Each branch pipe
a = 10m
ex) A6UW406FA0 b = 8m
c = 5m
A A
C
d = 3m
e = 10m
• CF = 6-5 = 1
a b c
❖ Additional Charge
7k 9k 9k = (30-5) x 50
B + (10-5) x 20
+ (8-5) x 20
+ (5-5) x 20
+ (3-5) x 20
d e
+ (10-5) x 30
9k 18k - (1 x 100)
Caution = 1250+100+60+0-40+150-100 = 1420 g

Regulation for refrigerant leakage(in Europe)


: the amount of refrigerant leakage should satisfy the following equation for human safety.

Total amount of refrigerant in the system


0.3 ( kg / m3 )
Volume of the room at which indoor unit of the least capacity is installed

Copyright ©2007 LG Electronics. Inc. All right reserved. - 82 -


LGE Internal Use Only
Only for training and service purposes
Installation

❐ If the above equation can not be satisfied, then follow the following steps.
- Selection of air conditioning system: select one of the next
1. Effective opening part Installation
2. Reconfirmation of outdoor unit capacity and piping length
3. Reduction of the amount of refrigerant
4. 2 or more security device installation of alarm for gas leakage
- Change indoor unit type
: installation position should be over 2m from the floor (Wall mounted type → Cassette type)
- Adoption of ventilation system
: choose ordinary ventilation system or building ventilation system
- Limitation in piping work
: design for earthquake-proof and prevention against thermal stress
2.4 Piping connection size

A B
Liquid mm Ø 9.52 Adjust to indoor unit
piping size
Gas mm Ø19.05

BD Unit
A
A

A6UW406FA0 A B
B B B B B

Y-Branch

A B
Liquid mm Ø 6.35 Adjust to indoor unit
piping size
Gas mm Ø15.88

A4UW306FA1 B B B

Copyright ©2007 LG Electronics. Inc. All right reserved. - 83 -


LGE Internal Use Only
Only for training and service purposes
Installation

2.5 Necessity of a trap


Since there is fear of the oil held inside the riser piping flowing back into the compressor when stopped and caus-
ing liquid compression phenomenon, or cases of deterioration of oil return, it will be necessary to provide a trap at
an appropriate place in the riser gas piping.
CAUTIONS
• Capacity is based on standard length and maximum
allowance length is on the basis of reliability.
• Oil trap should be installed every 5~7 meters.

In case more then 5m

2.6 Y-Branch(Standard accessory) [unit:mm]


Gas Pipe Liquid Pipe

Ø19.05 Ø19.05 Ø9.52 Ø9.52

Ø9.52
Ø19.05

Y branch
A To Outdoor Unit
B B To BD Unit
A

• Ensure that the branch pipes are attached horizontally or vertically (see the diagram below.)
Horizontal
plane Facing upwards

Within +/- 10°

A
Viewed from point A
in direction of arrow

• There is no limitation on the joint mounting configuration.


• If the diameter of the refrigerant piping selected by the procedures described is different from the size
of the joint, the connecting section should be cut with a pipe cutter.
• Branch pipe should be insulated with the insulator in each kit.
Tape
(field supply)

Liquid and gas Insulator for


Insulator
pipe joints field piping
(included with kit)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 84 -


LGE Internal Use Only
Only for training and service purposes
Installation

Test Running
SPLIT, ART cool, ART cool deluxe Type
1. Check that all tubing and wiring have been properly con- Bolt
nected.
2. Check that the gas and liquid side service valves are
fully open.
1) Prepare remote controller
Remove the battery cover by pulling it according to
the arrow direction.
Insert new batteries making sure that the (+) and (–) Tubing connection
of battery are installed correctly.
Reattach the cover by pushing it back into position. 4) Evaluation of the performance
Operate unit for 15~20 minutes, then check the system
refrigerant charge:
1. Measure the pressure of the gas side service valve.
2. Measure the temperature of the intake and discharge of
air.
3. Ensure the difference between the intake temperature
and the discharge is more than 8°C (Cooling) or reverse-
ly (Heating).

NOTE: Intake temperature


• Use 2 AAA(1.5volt) batteries. Do not use rechargeable
batteries.
Discharge air
• Remove the batteries from the remote controller if the sys-
tem is not going to be used for a long time.
2) Precautions in test run
■ The initial power supply must provide at least 90% of
the rated voltage. Discharge
Otherwise, the air conditioner should not be operated. temperature
■ For test run, carry out the cooling operation firstly Intake temperature
even during heating season. If heating operation is Discharge air
carried out firstly, it leads to the trouble of compres-
sor. Then attention must be paid.
■ Carry out the test run more than 5 minutes without
fail. (Test run will be cancelled 18 minutes later auto-
matically)
■ The forced operation is started by pressing button for
2 seconds. (Cassette Type)
The test run is started by pressing button for 5 sec-
onds. (Cassette Type)
The test run is started by pressing timer cancel button Discharge
five times continuously. (Room type) temperature

■ To cancel the test run, press any button. Intake temperature

3) Settlement of outdoor unit


■ Anchor the outdoor unit with a bolt and nut(ø10mm) Discharge air
tightly and horizontally on a concrete or rigid mount.
■ When installing on the wall, roof or rooftop, anchor the
mounting base securely with a nail or wire assuming the
influence of wind and earthquake.
■ In the case when the vibration of the unit is conveyed to
the hose, secure the unit with an anti-vibration rubber. Discharge
temperature

Copyright ©2007 LG Electronics. Inc. All right reserved. - 85 -


LGE Internal Use Only
Only for training and service purposes
Installation

CVT Type

1) Connection of power supply

1. Connect the power supply cord to the inde-


pendent power supply.
• Circuit breaker is required.
2. Prepare the remote control.
• Insert two batteries provided.
Remove the battery cover from the remote con-
troller.
• Slide the cover according to the arrow direction.
Insert the two batteries.
(Two "R03" or "AAA" dry-cell batteries or equiva-
lent.)
• Be sure that the (+) and (-) directions are cor-
rect.
• Be sure that both batteries are new.
Re-attach the cover.
• Slide it back into position.
3. Operate the unit for fifteen minutes or more.

2) Evaluation of the performance


1. Measure the temperature of the intake and dis-
charge air.
R

2. Ensure the difference between the intake temper-


ature and the discharge one is more than 8°C
(Cooling) or reversely (Heating).
Thermometer

3) Selection of the slide switch according


to installation method
1. In case the indoor unit is installed on the floor,
please change the side switch which is on the
Main PCB Assembly to the 'BOTTOM' state.
2. In case the indoor unit is installed under the ceil-
ing, please change the slide switch which is on
the Main PCB Assembly to the ' CEILING' state.

The initial state of the slide switch is set for


the bottom installation.

CN_INSTALL

CEILING BOTTOM

Copyright ©2007 LG Electronics. Inc. All right reserved. - 86 -


LGE Internal Use Only
Only for training and service purposes
Installation

Ceiling Cassette Type

1) PRECAUTIONS IN TEST RUN


• The initial power supply must provide at least 90% of the rated voltage.
Otherwise, the air conditioner should not be operated.
For test run, carry out the cooling operation first even during winter season. If heating operation is
Caution carried out first, it leads to the trouble of compressor.
Carry out the test run more than 5 minutes without stopping.
(Test run will be cancelled 18 minutes later automatically)
• The test run is started by pressing the room temperature checking button and down timer button for 3 sec-
onds at the same time.
• To cancel the test run, press any button.

CHECK THE FOLLOWING ITEMS WHEN INSTALLATION IS COMPLETE


• After completing work, be sure to measure and record trial run properties, and store measured data, etc.
• Measuring data are room temperature, outside temperature, suction temperature, blow out temperature,
air velocity, air volume, voltage, current, presence of abnormal vibration and noise, operating pressure, piping
temperature.
• As to the structure and appearance, check following items.

❏ Is the circulation of air adequate? ❏ Does the romote controller works properly?
❏ Is the drainage OK? ❏ Is there any error on wiring?
❏ Is the heat insulation complete ❏ Aren't terminal screws loosened?
(refrigerant and drain piping)?
❏ Is there any leakage of refrigerant?
M4......118N.cm{12kgf.cm} M5......196N.cm{20kgf.cm}
M6......245N.cm{25kgf.cm} M8......588N.cm{60kgf.cm}

Copyright ©2007 LG Electronics. Inc. All right reserved. - 87 -


LGE Internal Use Only
Only for training and service purposes
Installation

5. Branch Distributor

PRECAUTIONS FOR SELECTING THE LOCATION


The BD unit is for indoor use. Install in a location such as above a ceiling or behind a wall in accordance with the
following conditions:
• That the unit is fully supported, and is in a location with little or no vibration.
• That the refrigerant pipes for the indoor and outdoor units can be repaired with ease, and that the units are
placed well within the distance from each other allowed by the pipe length.
• That there is nothing nearby that produces heat or steam(gas).
• When installing, that there is enough carity for servicing the unit.
• Do not install in location that is hot or humid for long periods of time.
• A well-ventilated area.
• Do not install near bedrooms. The sound of refrigerant flowing through the piping may sometimes be audible.
For restrictions on installation, refer to "INSTALLATION".

System Layout and Piping Length


For installation of the indoor units. Follow the instructions in the installation manual for each unit.
System Layout

Distributor Unit
For 2 rooms : PMBD3620 (Ø9.52, Ø6.35)
For 3 rooms : PMBD3630 (Ø9.52, Ø6.35)
For 4 rooms : PMBD3640 (Ø9.52, Ø6.35) Branch Branch
Pipe
Distributor
For 3 rooms : PMBD7230 (A: Ø12.7, Ø6.35) A L1 L2 L3 L4

(B: Ø15.88, Ø6.35)


h2
(C: Ø15.88, Ø6.35) Branch
Distributor

Do not connect more than 8 indoor


units together choose the distributor L5 L6 L7 L8
h1
unit type (2rooms,3rooms or 4rooms)
according to the installation pattern

• Y Branch Pipe
- Included in outdoor unit
- Can not be purchased separately

Main Pipe

30K(4rooms) 40K(6rooms) 48K~56K(7~8rooms)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 88 -


LGE Internal Use Only
Only for training and service purposes
Installation

Piping length and elevation


(m)
No. Length 4 room 6 room 7 room 8 room
(1) Total main piping length A+B 15 50 50 50
(2) Total branch piping length L1+L2+L3+L4+L5+L6+(L7)+(L8) 50 50 60 60
(3) Max. each branch piping length L1, L2, L3, L4, L5, L6, L7,L8 15 15 15 15
(4) Total system piping length (Total main) + (Tatal branch) 65 100 110 120
(5) Maxium Level in - out h1 15 30 30 30
(6) Maxium Level in - in h2 7.5 10 10 10

Installation
• This unit may be installed suspended from the ceiling or mounted on the wall.
• This unit may only be installed horizontally , as shown in the diagram below. (Side B is facing up) However, it may
be freely installed in any direction, forward or backward, and to the sides.
• Be sure to secure a 600mm square opening for service and inspection as shown in the diagram below, for both
ceiling - suspended installation and wall-mounted installation.
• BD unit does not require drain treatment as it uses internal insulation.
• Service direction is the side B and C
• The piping for the indoor unit may be led around in direction A
• The inclination of side B must be within ±5 degree forward or backward or to the sides.

(Servicing space)
Min 30

Ø19.05
(298)

(337)

A
250

Min 400
Ø9.52
Min 400

(Side view)

245 (LEV service)


Suspension bolt pitch.
Main Pipe
B
432 30 50
(36) 50 50 50
(150)

(111)

600
(38) 50

250 or more

72 300 60
(56) 50 50 50 Branch Pipe Cover Control
C
Inspection opening
(Controller service)
600
(Bottom view)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 89 -


LGE Internal Use Only
Only for training and service purposes
Installation

Installation of The Main Unit

NOTICE :
• This unit has two different installation types:
(1) Ceiling-suspended type and (2) wall-mounted type.
• Choose the proper installation pattern according to the
location of installation.
• The installation location for printed wiring board can be
changed.
Follow the procedure specified in the "CONNECTING
THE WIRING" section to change the location.
(1) Ceiling-suspended type (2) Wall-mountde type

(1) Ceiling-suspended type Procedure


(1) Fix the fumished hanger metal with two screws.(4 locations in total).
(2) Using an insert-hole-in- anchor, hang the hanging bolt.
(3) Install a hexagon nut and a flat washer (locally-procured)to the hanging bolt as
shown in the figure in the left, and ift the main unit to hang on the hanger metal.
(4) After checking with a level that the unit is level, tighten the hexagon nut.
* The tilt of the unit should be within ±5° in front/back and left/right.

BD unit

Six-sided Nut 15.00


(M10 or M8)

Hanger metal

Flat washer

Hanging bolt
(M10 or M8)

(2) Wall-mounted type

Procedure
(1) Fix the fumished hanger metal with two screws.
(3 locations in total).
Screws(M5) (2) After checking with a level that the unit is level, fix the unit with the
(locally procude) furnished wood screws.
* The tilt of the unit should be within ±5° in front/back and left/right.
* Block up the parts of hanger holes (2 places) by using insulation
PE after installing the hanger.

CAUTIONS
• Once a screw-hole on the main unit has had a screw hammered in, make sure to either hammer it again or cover it with
alumium tape.(This is to prevent condensation)
• Be sure to install the unit with the ceiling-sie up.
• Do not install near bedrooms. the sound of refrigerant flowing through the piping may sometimes be audible.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 90 -


LGE Internal Use Only
Only for training and service purposes
Installation

Connection of Piping

• When connecting indoor units, make sure to connect refrigerant pipes and connection wires to the appropriate con-
nection ports maked with matching alphabets. (A, B, C, D)
NOTICE : A B C D
• Be sure to mark all the local refrigerant piping(liquid
pipes, gas pipes, etc.) for each indoor unit designating
clearly which room it belongs in.(A, B, C, D)

NOTICE :
For flaring work the piping, follow the instructions in the installation manual to each unit.

Connecting the pipings to the indoor unit


and drain hose to drain pipe
1. Align the center of the pipings and sufficiently tighten
the flare nut by hand. BD Unit Socket Flare nut Pipes
2. Tighten the flare nut with a wrench.
Outside diameter Torque
mm inch kg.m Open-end wrench (fixed)

Ø6.35 1/4 1.8


Flare nut
Ø9.52 3/8 4.2
Ø12.7 1/2 5.5 Wrench Connection pipe

Ø15.88 5/8 6.6 BD Unit Socket


Ø19.05 3/4 6.6

Wrap the insulation material around the


connecting portion. BD Unit Indoor unit pipe

1. Overlap the connection pipe insulation material and Vinyl tape (wide) Wrap with vinyl tape
the indoor unit pipe insulation material. Bind them Connecting cable
together with vinyl tape so that there is no gap.
Pipe
2. Wrap the area which accommodates the rear piping Vinyl tape(narrow)
housing section with vinyl tape.

Close up a socket for unoccupied room


with a brass cap.
1. Align the center of the piping and sufficiently tighten
the brass cap by hand.
BD Unit Socket Brass cap Pipe sealed
2. Tighten the brass cap with a wrench. or welded
3. Wrap the joint part with insulation.

CAUTIONS
• Never use the plastic cap for sealing.
• Make sure to use brass cap with the end of
pipe sealed or welded tightly.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 91 -


LGE Internal Use Only
Only for training and service purposes
Installation

Connection of Wiring

• Connect refrigerant pipes and connection wires to the appropriate ports maked with matching alphabets (A, B and
C) on this unit.
• Follow the instructions on the wiring nameplate to connect the connection wires of indoor/outdoor units to terminal
board numbers.(1, 2 and 3) Always fix each ground wire separately with a ground screw.(See the figure below.)
• After completing the wiring, fix the outer coating of wires securely with wire clamps. The wire clamp on indoor unit
side is furnished. Follow the procedure below to install.
• Refer to the circuit diagram on the control cover inside outdoor unit.

NOTICE :
The terminal board numbers are arranged from top to bottom in order of 1, 2 and 3.

In Case of 3 rooms

Warning
Do not use tapped wires, stand wires,
C room extensioncords, or starbust connec-
A tions, as they may cause overtheating,
B room electrical shock, or fire.
B

A room C

CN-PWR

Connection wire for indoor units Connection wire for outdoor units
(H05VV, 4wires, 0.75mm) (H05RV, 4wires, 1.2mm)

(1) Remove the control cover. Loosen the two screws,


and slide thecover in thedirection of thearrow.

(3) Put in the cover in the direction of the arrow then


tighten the screws.

(2) Perform wiring with reference the wiring diagram on


a control cover of outdoor unit. Allow 300 mm for the
pulling-out section of harness. Fix the wires com-
pletely with wire clamps(4 locations).

Copyright ©2007 LG Electronics. Inc. All right reserved. - 92 -


LGE Internal Use Only
Only for training and service purposes
Operation

Operation
Function of control
1. MAIN UNIT FUNCTION
• DISPLAY
Operation Indicator
• On while in appliance operation, off while in appliance pause
• Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)

Sleep Timer Indicator


• On while in sleep timer mode, off when sleep timer cancel or appliance operation pause

Timer Indicator
• On while in timer mode (on/off), off when timer mode is completed or canceled

Defrost Indicator
• Off except when hot start during heating mode operation or while in defrost control

■ Cooling Mode Operation


• When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan
stop.
• When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp ➲ Setting Temp+0.5°C
Compressor OFF Temp ➲ Setting Temp-0.5°C
• While in compressor running, operating with the airflow speed set by the remote control. While compressor is
off fan operates at low speed regardless of the setting.

■ Soft Dry Operation Mode


• When the dehumidification operation input by the remote control is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26°C ≤ Intake Air Temp ➲ 25°C
24°C ≤ Intake Intake Air Temp<26°C ➲ Intake Air Temp-1°C
18°C ≤ Intake Intake Air Temp<24°C ➲ Intake Air Temp-0.5°C
Intake Air Temp<18°C ➲ 18°C
• While compressor off, the indoor fan repeats low airflow speed and stop.
• While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification
operation and 4-min compressor off repeat.
Compressor ON Temp. ➲ Setting Temp+0.5°C
Compressor OFF Temp. ➲ Setting Temp-0.5°C
• In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.

■ Heating Mode Operation


• When the intake air temp reaches +3°…above the setting temp, the compressor is turned off. When below the
setting temp, the compressor is turned on.
Compressor ON Temp. ➲ Setting Temp.
Compressor OFF Temp. ➲ Setting Temp.+3°C
• While compressor on, the indoor fan is off when the indoor pipe temp. is below 20°C, when above 27°C , it

Copyright ©2007 LG Electronics. Inc. All right reserved. - 93 -


LGE Internal Use Only
Only for training and service purposes
Operation

operates with the low or setting speed. When the indoor pipe temp is between 20°C and 27°C, it operates with
Super-Low(while in sleep mode, with the medium airflow speed).
• While compressor off, the indoor fan is off when the indoor pipe temp is below 33°C, when above 35°C , it
operates with the low airflow speed.
• While in defrost control, the indoor is outdoor fans are turned off.

■ Defrost Control(Heating)
• Defrost operation is controlled by timer and sensing temperature of outdoor pipe.
• The first defrost starts only when the outdoor pipe temperature falls below -6°C after 35 minutes passed from
starting of heating operation and more than 4 minutes operation of compressor.
• Defrost ends after 12 minutes passed from starting of defrost operation when the outdoor pipe temperature
rises over 15°C even before 12 minutes.
• The second defrost starts only when the outdoor pipe temperature falls below -6°C after 35 minutes passed
from ending of the first defrost and more than 4 minutes operation of compressor.

■ Fuzzy Operation
• When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since
the operation off, the operation mode is selected.
• When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only
the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake air
temp at that moment as follows.
24°C ≤ Inatake Air Temp ➲ Fuzzy Operation for Cooling
21°C ≤ Inatake Air Temp<24°C ➲ Fuzzy Operation for Dehumidification
Inatake Air Temp<21°C ➲ Fuzzy Operation for Heating
• If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.

1) Fuzzy Operation for Cooling


• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is
turned on.
Compressor ON Temp ➲ Setting Temp +0.5°C
Compressor OFF Temp ➲ Setting Temp + 0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C≤ Intake Air Temp ➲ 25°C
24°C≤ Intake Air Temp<26°C ➲ Intake Air Temp + 1°C
22°C≤ Intake Air Temp<24°C ➲ Intake Air Temp + 0.5°C
18°C≤ Intake Air Temp<22°C ➲ Intake Air Temp
Intake Air Temp<18°C ➲ 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temper-
ature.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 94 -


LGE Internal Use Only
Only for training and service purposes
Operation

2) Fuzzy Operation for Dehumidification


• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor
is turned on.
Compressor ON Temp ➲ Setting Temp + 0.5°C
Compressor OFF Temp ➲ Setting Temp+0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C ≤ Intake Air Temp ➲ 25°C
24°C ≤ Intake Air Temp<26°C ➲ Intake Air Temp+1°C
22°C ≤ Intake Air Temp<24°C ➲ Intake Air Temp+0.5°C
18°C ≤ Intake Air Temp<22°C ➲ Intake Air Temp
Intake Air Temp<18°C ➲ 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in
dehumidification operation.

3) Fuzzy Operation for Heating


• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3°C or more above
the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on.
Compressor ON Temp ➲ Setting Temp
Compressor OFF Temp ➲ Setting Temp + 3°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
20°C≤Intake Air Temp ➲ Intake Air Temp + 0.5°C
Intake Air Temp<20°C ➲ 20°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the
intake air temperature and the setting temperature.

■ Airflow Speed Selection


• The airflow speed of the indoor fan is set to high, medium, low, or power (auto) by the input of the airflow
speed selection key on the remote control.

■ On-Timer Operation
• When the set time is reached after the time is input by the remote control, the appliance starts to operate.
• The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.
• If the appliance is operating at the time set by the timer, the operation continues.
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.

■ Off-Timer Operation
• When the set time is reached after the time is input by the remote control, the appliance stops operating.
• The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.
• If the appliance is on pause at the time set by the timer, the pause continues.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 95 -


LGE Internal Use Only
Only for training and service purposes
Operation

■ Off-Timer <=> On-Timer Operation


• When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is
carried out according to the set time.

■ Sleep Timer Operation


• When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appli-
ance operation, the operation of the appliance stops.
• While the appliance is on pause, the sleep timer mode cannot be input.
• While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature
increases by 1°C. After another 30 min elapse, it increases by 1°C again.
• When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to
the low.
• When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to
the medium.

■ Chaos Swing Mode


• By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are
fixed to the desired direction.
• While in Chaos Swing mode, the angles of cooling and heating cycle operations are different.

■ Chaos Natural Wind Mode


• When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air-
flow mode is operated for 2~15 sec. randomly by the Chaos Simulation.

■ Jet Cool Mode Operation


• While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the
other mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.
• In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
• In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C.
• When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
• When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then
operated in order that the air outflow could reach further.

■ Auto Restarting Operation


• When the power is restored after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 96 -


LGE Internal Use Only
Only for training and service purposes
Operation

■ Forced Operation
• To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
• When the power is supplied while the slide switch is on the forced operation position, or when the slide switch
position is switched to the Auto Restarting (or test operation) position or switched from the remote control
position to the forced operation position while the power is on, the forced operation is carried out.
• When the slide switch position is switched from the forced operation position to the Auto Restarting position or
the remote control position, the forced operation is canceled and the appliance stops operating.
• In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the opera-
tion condition is set according to the intake air temperature as follows.
24°C≤Intake Air Temp ➲ Cooling Mode Operation, 22°C, High Speed
21°C≤Intake Air Temp<24°C ➲ Dehumidification Operation, 23°C, High Speed
Intake Air Temp<21°C ➲ Heating Mode Operation, 24°C, High Speed

■ Buzzer Sounding Operation


• When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.
• When the appliance-pause key is input by the remote control, the long "beep—" sounds.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 97 -


LGE Internal Use Only
Only for training and service purposes
Operation

Function of Indoor Unit

Split Type Indoor Unit

Operation ON/OFF by Remote controller

Sensing the Room Temperature

• Room temperature sensor. (THERMISTOR)


Room temperature control

• Maintains the room temperature in accordance with the Setting Temp.


Starting Current Control

• Indoor fan is delayed for 5 seconds at the starting.

Time Delay Safety Control

• Restarting is delayed for approx. 3 minutes.

Indoor Fan Speed Control

• High, Med, Low, Chaos


Operation indication Lamps (LED)

--- Lights up in operation

--- Lights up in Sleep Mode

--- Lights up in Timer Mode

--- Lights up in Deice Mode

Soft Dry Operation Mode

• Intermittent operation of fan at low speed.


Sleep Mode Auto Control
Deice (defrost) control (Heating)
• The fan is switched to low(Cooling), med(Heating) speed.
• Both the indoor and outdoor fan
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
stops during deicing.
Natural Air Control by CHAOS Logic • Hot start after deice ends.

• The fan is switched to intermittent or irregular operation Hot-start Control (Heating)


• The fan speed is automatically switched from high to low speed. • The indoor fan stops until the
* Airflow Direction Control evaporator piping temperature will
be reached at 27°C.
• The louver can be set at the desired position or swing
up and down automatically.(Model base)

"Wall Mounted Type is standard"


* Functions is dependent on model type.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 98 -


LGE Internal Use Only
Only for training and service purposes
Operation

Art Cool Type Indoor Unit

Operation ON/OFF by Remote controller

Sensing the Room Temperature


• Room temperature sensor. (THERMISTOR)

Room temperature control

• Maintains the room temperature in accordance with the Setting Temp.

Starting Current Control


• Indoor fan is delayed for 5 sec at the starting.

Time Delay Safety Control

• Restarting is inhibited for approx. 3 minutes.

Indoor Fan Speed Control


• High, Med, Low, CHAOS, JET COOL

Operation indication Lamps (LED)

--- Lights up in operation


--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Defrost Mode (for Heating Model)
OUTDOOR--- Lights up in compressor operation (for Cooling Model)

Soft Dry Operation Mode


• Intermittent operation of fan at low speed.

Sleep Mode Auto Control PLASMA


• The fan is switched to low(Cooling), med(Heating) speed. • The function will be operated while in any
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours. operation mode with selecting the function.
• The function is to be stopped while it is
Natural Air Control by CHAOS Logic operating with selecting the function.
• The fan is switched to intermittent or irregular operation Defrost(Deice) control (Heating)
• The fan speed is automatically switched from high to low speed.
• Both the indoor and outdoor fan stops dur-
Airflow Direction Control ing defrosting.
• The louver can be set at the desired position or swing Hot-start Control (Heating)
up and down automatically.
• The indoor fan stops until the
evaporator pipe temperature will be reached
at 28°C.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 99 -


LGE Internal Use Only
Only for training and service purposes
Operation

Art Cool Deluxe Type Remote Controller

Operation ON/OFF

Operation Mode Selection


Cooling Operation Mode.( ) Auto Operation Mode.( )
(Cooling (Heating
model only) model only) Healthy Dehumidification Operation Mode.( ) Heating Operation Mode.( )
Fan Speed Selection

(Low) (Med) (High)

Room, Temperature Checking


: (High:39°C Low:11°C)
Temperature Setting
TEMPERATURE LOW HIGH

Cooling Down to 18°C Heating Down to 16°C


Up to 30°C Up to 30°C
JET COOL

Setting the Time or Timer

Timer Selection
: OFF, ON, OFF ON
ON OFF

Timer Setting

SET

Timer Cancel
CANCEL
: Cancel Sleep Mode, Timer ON or Timer OFF

Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer

Airflow Direction Control


2nd F

Air Circulation
Reset
: Fan Operates without cooling or heating.
Horizontal Airflow Direction Control Button(Optional)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 100 -


LGE Internal Use Only
Only for training and service purposes
Operation

Duct Type Remote Controller

Operation ON/OFF

Operation Mode Selection

Cooling Operation Mode ( ) Soft Dry Operation Mode ( )


(Cooling (Heating Heating Operation Mode ( ) Auto Operation Mode ( )
model only) model only)

Fan Speed Selection

LO (Low) MED (Med) HI (High)


Room Temperature Display

: High:39°C ↔ LOW:11°C

Temperature Setting
Down to 18°C Down to 16°C
Cooling Up to 30°C Heating Up to 30°C

Setting the Timer


Timer Cancel

Weekly Program
Program Week Holiday

SET/CLR

Hour Min

Fan Operation Mode : Fan Operates without cooling & heating

Phase Control Setting

Timer

Copyright ©2007 LG Electronics. Inc. All right reserved. - 101 -


LGE Internal Use Only
Only for training and service purposes
Operation

CST Type Remote Controller

Operation ON/OFF

Operation Mode Selection

Cooling Operation Mode ( ) Soft Dry Operation Mode ( )


(Cooling (Heating Heating Operation Mode ( ) Auto Operation Mode ( )
model only) model only)

Fan Speed Selection

SLO (Super Low) LO (Low) MED (Med) HI (High) JET AUTO


Room Temperature Display

: High:39°C ↔ LOW:11°C

Temperature Setting
Down to 18°C Down to 16°C
Cooling Up to 30°C Heating Up to 30°C

Setting the Timer


Timer Cancel

Weekly Program
Program Week Holiday

: Fan Operates without cooling & heating


SET/CLR

Hour Min

Fan Operation Mode

Copyright ©2007 LG Electronics. Inc. All right reserved. - 102 -


LGE Internal Use Only
Only for training and service purposes
Operation

Convertible Type Remote Control


Operation ON/OFF

Operation Mode Selection


Cooling Operation Mode.( ) Auto Operation Mode.( )
(Cooling (Heating
model only) model only) Healthy Dehumidification Operation Mode.( ) Heating Operation Mode.( )
Fan Speed Selection

(Low) (Med) (High) (CHAOS)

Room, Temperature Checking


: (High:39°C Low:11°C)
Temperature Setting
TEMPERATURE LOW HIGH

Cooling Down to 18°C Heating Down to 16°C


Up to 30°C Up to 30°C
JET COOL

PLASMA(Optional)

Setting the Time or Timer

Timer Selection

ON OFF
: OFF, ON, OFF ON
Timer Setting

SET

Timer Cancel
CANCEL
: Cancel Sleep Mode, Timer ON or Timer OFF
Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control

Air Circulation
: Fan Operates without cooling or heating.
Horizontal Airflow Direction Control Button(Optional)

2nd F

Reset

Copyright ©2007 LG Electronics. Inc. All right reserved. - 103 -


LGE Internal Use Only
Only for training and service purposes
Operation

Function of Outdoor Unit

Outdoor Unit

Two Comp algorithm


• Inverter Comp is first priority and then Constant Comp is turning on responding to load condtion.

Operating Frequency
• Inverter Frequency varies considering condition such as room temp,outdoor temp, operating room
number,Temp gap between room temp and set temp and so on.

LEV Control
• LEV pulse is modulated to keep constant superheat or subcooling.

Out door Fan Control

• Outdoor fan operates at High/Low or Off to respond to the load condition.

R/Valve Control

• Convert R/Valve to change cooling to heating, heating to cooling.

Comp Pre-Heat Logic

• Checking outdoor temp, D-Pipe temp,Heat Sink Temp, operate compressor at low frequency upto
5min to preheat oil.

Defrost Function

• After 35 min heating operation, check the defrost condition and if outdoor pipe temp is below -6°C and
released from deice operation in case outdoor pipe temp is over 15°C or 7 min cooing mode.
• To deice outdoor heat exchanger in low temp condtion, convert operating mode from heating to
cooling, in this case, indoor and outdoor fan is off.

Oil Return System

• In heating operation, every 3 hours, changes from heating to cooling for 5 min to return the oil in piping
to compressor.

IPM Over Heat Protection

• To protect IPM overheat, down comp Hz.

Comp Overload Protection

• To protect comp from being overload, down comp Hz.

Low Pressure Protection

• If cylce pressure is low (around 0.3kgf/cm2), turn off comp and outdoor fan.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 104 -


LGE Internal Use Only
Only for training and service purposes
Operation

Remote Control Operation


The Remote Controller transmits the signals to the system.

1 START/STOP BUTTON
Operation starts when this button is pressed and
Signal transmitter stops when the button is pressed again.
2 OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3 ROOM TEMPERATURE
SETTING BUTTONS
Used to select the room temperature.
4 INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high and CHAOS.
5 1 5 JET COOL
6
Used to start or stop the speed cooling/heating.
3 (Speed cooling/heating operates super high fan
speed.)
4
6 CHAOS SWING BUTTON
2 10
CANCEL Used to stop or start louver movement and set the
7 9 desired up/down airflow direction.
ON OFF SET
11 AUTO CLEAN 16 7 ON/OFF TIMER BUTTONS
8 Used to set the time of starting and stopping opera-
13 tion.
12
8 TIME SETTING BUTTONS
14 15
Used to adjust the time.
17
9 TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is
Flip-up door obtained and to cancel the Timer operation.
(opened) 10 SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
Operation Mode
11 AIR CIRCULATION BUTTON
Cooling Operation Used to circulate the room air without cooling or
heating.
Auto Operation 12 ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
Healthy Dehumidification Operation 13 PLASMA(OPTIONAL)
Used to start or stop the plasma-purification func-
Heating Operation
tion.
14 RESET BUTTON
• Cooling Model( ), Heat Pump Model( ) Initialize remote controller.
15 2nd F Button
Used prior to using modes printed in blue at the bot-
tom of buttons.
16 AUTO CLEAN (Model Base)
Used to set Auto Clean mode.
17 HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON (OPTIONAL)
Used to set the desired horizontal airflow direction.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 105 -


LGE Internal Use Only
Only for training and service purposes
Operation

Duct Type Remote Controller

AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION


Room Temp
HI AUTO Heater Preheat
1
MED JET Defrost Humidify
LO SLo Filter Out door
2ndF Time ZONE 1 2 3 4
Timer Operation unit No Func Program set
On Off
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

3
Signal receptor 2

8 5
Timer Cancel 2ndF
9
10 Program Week Holiday
6
11 PLASMA AUTO 4
12 Set/Clr
7
13 Hour Min
RESET

14 15

1 Operation display 9 Timer Set Button


Displays the operation conditions. Used to set the timer when the desired time is
obtained.
2 On/Off Button
Operation starts when this button is pressed, and 10 Week Button
stops when the button is pressed again. Used to set a day of the week.

3 Set Temperature Button 11 Program Button


Used to set the temperature when the desired Used to set the weekly timer.
temperature is obtained.
12 Holiday Button
4 FAN Operation Button Used to set a holiday of the week.
Used to circulate room air without cooling or
heating. 13 Time Set Button
Used to set the time of the day and change the
5 Fan Speed Button time in the weekly timer Function.
Used to set the desired fan speed.
14 Set and Clear Button
6 Operation Mode Selection Button Used to set and clear the weekly timer.
Used to select the operation mode.
• Auto Operation Mode 15 Reset Button
• Cooling Operation Mode Used to set the current time and clear the setting
• Soft Dry Operation Mode time.
• Heating Operation Mode(except cooling model)

7 Room Temperature Checking Button


Used to check the room temperature.

8 Timer Cancel Button


Used to cancel the timer.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 106 -


LGE Internal Use Only
Only for training and service purposes
Operation

CST Type Remote Controller

AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION


Room Temp
HI
MED
AUTO Heater Preheat
JET Defrost Humidify 1
LO SLO Filter Out door
2ndF Time ZONE 1 2 3 4
Timer Operation unit No Func Program set
On Off
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

3
17 2
10 Timer Cancel 2ndF
5
11 6
12 Program Week Holiday
13 4
Plasma
14 Set/Clr
7
15 Hour Min RESET 8
16 9
18

1 Operation display 9 Plasma Air Clean Button (Option)/Heater(Option)


Displays the operation conditions.
10 Timer Cancel Button
2 On/Off Button Used to cancel the timer.
Operation starts when this button is pressed, and
11 Timer Set Button
stops when the button is pressed again.
Used to set the timer when the desired time is
3 Set Temperature Button obtained.
Used to set the temperature when the desired temper-
12 Week Button
ature is obtained.
Used to set a day of the week.
4 FAN Operation Button
13 Program Button
Used to circulate room air without cooling or heating.
Used to set the weekly timer.
5 Fan Speed 14 Holiday Button
Used to set the desired fan speed or select Jet cool Used to set a holiday of the week.
mode.
15 Time Set Button
6 Operation Mode Selection Button Used to set the time of the day and change the time in
Used to select the operation mode. the weekly timer Function.
• Auto Operation Mode
• Cooling Operation Mode 16 Set and Clean/Ventilation(Option)
• Soft Dry Operation Mode Used to set and clear the weekly timer.
• Heating Operation Mode(except cooling model) 17 Swirl Button
7 Auto Swing Button Used to select swirl mode.
Used to swing up and down/right and left(option) Jet Cool Button
Auto Swing Button(1 Way 06 Model)
8 Room Temperature Checking Button/Filter sign
Release(Option) 18 Reset Button
Used to check the room temperature. Used to set the current time and clear the setting time.

❈ Display temperature can be different from actual room temperature if the remote controller is installed at the
place where sun-rays are falling directly or the place nearby heat source.
Note : 06 Model - AMNH09GTCC0, AMNH12GTCC0

Copyright ©2007 LG Electronics. Inc. All right reserved. - 107 -


LGE Internal Use Only
Only for training and service purposes
Operation

1) Two Thermistor System


(1) Open the rear cover of the wired remote-controller to set the mode.
(2) Select one of three selectable modes as follows.
• Position 1:
The room temperature is controlled by the thermistor of the main body.
• Position 2:
The room themperature is controlled by the thermistor of the wired remote-controller, control the
temperature according to the position of wired remote-controller.
• Position 3:
The room temperature is controlled by lower temperature between the temperature of main body and of
remote-controller sensor.
(3) Move the slide switch to set position.

Room Temp. sensor


Slide switch for 2 Thermistor
TH R13H R12H OP5R16H OP4
CO1H

R15H
OP2 OP1
R14H OP3 R19H
SW TH R11H

Position 2 REMO REMO


MAIN OP7
2TH R18H
Position 1 MAIN R17H
OP6

Position 3 2TH LO

C070
STAND
HI R03S

R04S
R01S

R02S
SW HIGH

(4) Close the rear cover and check if it works normally.

CAUTION: • Select the position after counselling with a customer.


• In case of cooling mode, room temperature is controlled by the
main body sensor.
• To control the room temperature by a wired remote controller,
install controller(room temp. sensor) to sense the temperature
more accurately.
• Maunfactured in the position 1.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 108 -


LGE Internal Use Only
Only for training and service purposes
Operation

2) Group Control(Optional Wiring)


• You can use a group control operation after connecting the brown and yellow wire of each air-conditioner.
• Remove the resistor "OP 7" in remote controller.
• It operates maximum 16 Units by only one Wired Remote Controller,
and each Unit starts sequentially to prevent overcurrent.

Wiring design
Main PCB
Indoor Unit 1 Indoor Unit 2 Indoor Unit 16
Terminal(Local Supply) Terminal(Local Supply) Terminal(Local Supply)
Block Block Block
Connector Connector Connector
RED(12V) RED(12V)
Main PCB YL(SIGNAL) Main PCB YL(SIGNAL) Main PCB
YL(SIGNAL)
BR(GND)
YL(SIGNAL)
BR(GND) #1 BR(GND)
YL(SIGNAL)
BR(GND) #2 .... BR(GND)
YL(SIGNAL)
BR(GND) #16

Connecting Cable(Local Supply)


....

AUTO SWING OPERATION SET TEMP


Room Temp
FAN SPEED
HI
MED
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Slide Switch OP7
LO Filter Out door

Timer
On Off
Operation unit

Set no. Time 01 03 05 07 09


Time
Program set

11 13
ZONE

15 17 19
1 2 3 4

21 23
Remote
Controller
PCB
Wired Remote Controller

Features
• Use Only One Wired Remote Controller with several air conditioners(max. 16 Units)
• Random starting to prevent overcurrent.

CAUTION: • Be careful not to exchange the color of wires.


• The maximum length of connecting wire should be below
200m(25Ω) on connecting each units.
• Use a wire more than 0.5mm2

Copyright ©2007 LG Electronics. Inc. All right reserved. - 109 -


LGE Internal Use Only
Only for training and service purposes
Operation

3) E.S.P.(External Static Pressure) Setting

(1) Open the rear cover of the wired remote-controller to set the mode.
(2) Select one of three selectable modes as follows.

■ Without Zone System


1. Position V-H, F-H:
• This position sets the maximum E.S.P as a default set.
2. Position V-L:
• This position sets the minimum E.S.P as a default set.

■ With Zone System


1. Position V-H:
• Maximum E.S.P setting & Fan speed is varied according to the state of dampers by micom.
2. Position F-H:
• Maximum E.S.P setting & Fan speed doesn't vary according to the opening & Closing of dampers.
3. Position V-L:
• Minimum E.S.P setting & Fan speed is varied according to the state of dampers by micom.

* Maximum : 8mmAq
Minimum : 0mmAq

(3) Move the slide switch to set position.

TH R13H R12H OP5R16H OP4


CO1H

R15H
OP2 OP1
R14H OP3 R19H
SW TH R11H

V-H REMO
MAIN
2TH OP7
R18H
R17H
F-H OP6

V-L LO
C070

STAND
HI R03S
R04S

R01S
R02S

SW HIGH

Slide switch for ceiling height

(4) Close the rear cover and check if it works normally.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 110 -


LGE Internal Use Only
Only for training and service purposes
Operation

4) How to Set E.S.P?

Procedure of RPM change:


Ex) External Static pressure is 4mmAq for Model 36K.
• To protect the unit, compressor is designed to be off during E.S.P. setting.

Push the"On/Off"button.
1 The unit will start.
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION
Room Temp
HI AUTO Heater Preheat
MED JET Defrost Humidify
LO Filter Out door
Time ZONE
Operation unit Program set

Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

Push the "Timer" and "Wind" button simultaneously for more then 3 seconds.
2
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION
Timer Room Temp
HI AUTO Heater Preheat
MED JET Defrost Humidify
LO Filter Out door
Time ZONE
Operation unit Program set

Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

Push the "Up" of "Down" button for E.S.P adjustment.


3 And, adjust the number which you want.(In this example, the number is "225". Refer to the
table 1 on the next page.)

AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION


Room Temp
HI AUTO Heater Preheat
MED JET Defrost Humidify
LO Filter Out door
Time ZONE 2
Operation unit Program set

Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

Note: The range of selection is from 1~254. Since, the display is two Digit only.
If the range selection is above 100 then the third digit will appear in the screen as shown.

Shift the fan speed mode by pressing the fan speed button.
4 And then, Adjust numbers of next steps by repeating the stage 3.
(In this example, the numbers are "237" and "243" respectly)

Push the "Timer" and "Wind" button simultaneously for more than 3 seconds.
5 Then, Wind Data is memorized by the EEPROM of the main PCB.
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION
Room Temp
HI AUTO Heater Preheat
MED JET Defrost Humidify
Timer LO Filter Out door
Time ZONE
Operation unit Program set

Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

Copyright ©2007 LG Electronics. Inc. All right reserved. - 111 -


LGE Internal Use Only
Only for training and service purposes
Operation

Duct ESP control table

Chassis Static Pressure(mmAq) 0 1 2


Ca(Btu/h) Step(Hi/Med/Lo) Setting Value
8 CMM 220 215 210
9k 7 CMM 240 235 230
6 CMM 255 250 245
10 CMM 175 170 150
BT 12k 9 CMM 200 190 185
8 CMM 220 215 210
14 CMM 170 150 130
18k 13 CMM 185 165 145
12 CMM 220 180 160

Chassis Static Pressure(mmAq) 0 2 4


Ca(Btu/h) Step(Hi/Med/Lo) Setting Value
10.5 CMM 225 220 210
9k 9 CMM 245 240 230
BP 8.5 CMM 254 253 250
11.5 CMM 210 200 100
12k 10 CMM 235 230 220
8.5 CMM 254 215 245

Chassis Static Pressure(mmAq) 0 2 4 6 8 10


Ca(Btu/h) Step(Hi/Med/Lo) Setting Value
16.5 CMM 235 230 225 215 180
18k 14.5 CMM 245 238 235 230 215
BH 13 CMM 254 252 248 245 240
18 CMM 220 205 190 170 1
24k 16.5 CMM 235 230 220 200 100
14 CMM 250 240 235 230 210

Chassis Static Pressure(mmAq) 0 2 4 6 8 10


Ca(Btu/h) Step(Hi/Med/Lo) Setting Value
26.5 CMM 153 150 150 148 130 1
30k 23 CMM 173 173 175 175 170 155
BG 20 CMM 195 195 193 193 190 190
32 CMM 230 230 225 220 150 1
36k 29 CMM 240 238 237 235 230 220
26.5 CMM 245 245 243 243 240 240

Copyright ©2007 LG Electronics. Inc. All right reserved. - 112 -


LGE Internal Use Only
Only for training and service purposes
Operation

Chassis Static Pressure(mmAq) 0 1 2 3 4


Ca(Btu/h) Step(Hi/Med/Lo) Setting Value
8.5 CMM 75 84 94 104 114
9k 7.5 CMM 69 77 88 99 110
B1 6.5 CMM 62 71 83 95 106
9.5 CMM 82 90 99 109 118
12k 8.5 CMM 75 84 94 104 114
7.5 CMM 69 77 88 99 110
15 CMM 90 97 105 114 122
18k 13.5 CMM 82 90 99 109 119
B2 11.5 CMM 75 84 93 103 114
17 CMM 110 117 125 129 -
24k 15 CMM 100 107 115 121 127
13.5 CMM 90 97 105 114 122

Copyright ©2007 LG Electronics. Inc. All right reserved. - 113 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Control Devices and Function


Simple Central Control
Features
• Easy operation button.
• Independent operation for 16 indoor units each.
• Simultaneous turn ON/OFF for all of indoor units connected.
• Easy change operation mode to cooling or heating
• Set and clear lock-mode for each indoor unit
• Simultaneously set and clear lock-mode for all of indoor units
connected.
• Display function for all of indoor units connected.

Term of Each part and Function

On/Off display LED Individual On/Off button


(TOTAL 16EA) • Control ON/OFF of a unit.
• On pressing individual on/off
button, display the present
operation state.
-Operation : green.
-Stop : off
-Error mode : blinking

Power display LED


• Indicate the state of DC
Power supply in central
control unit. TOTAL Off button
- On : red(Heating), green(Cooling) • Stop all linked units sequentially.
- Off : no signal
- Error mode : blinking with red color
TOTAL On button
• Operate all linked units sequentially.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 114 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Electrical wiring
■ PICTORIAL VIEW OF THE CONNECTION

Outdoor
Outdoor unit
unit
PI485 : PNF-P14A0M

MAIN PCB
L PI485

MAIN PCB Control Box

CN_CENTRAL

MAIN PCB

CN_CENTRAL N
L

10
G
PI485 A
B

VCC CENTRAL
GND
CN OUT C
CONTROL
D UNIT

• Special purchase: Central control, PI485(PNF-P14A0M)

■ ONE SIMPLE CENTRAL CONTROL CONNECTION

INDOOR UNIT 1 INDOOR UNIT


INDOOR UNIT 2 • SET The Address(Group No. & Indoor No.)
OUTDOOR INDOOR UNIT 3 * Refer to The Following sheet
MAIN PCB INDOOR UNIT 4 (1.3.5 Indoor unit Address setting method)
INDOOR UNIT 5 Vcc GND C D

INDOOR UNIT 6 CN-POWER


GND
BUS CN-COM B
B
BUS CN-POWER CN-COM A
A S1 S2 S4
L
GND LED2
LED3 LED4
+10V IC1P S5 S6 S3
+ + + +
+
LED5 LED7 LED8 TX1
D C GND VCC S9 S10 S11 S12
+ + +

Outdoor
Outdoor unit
unit LED9 LED10

S14
LED11

+ S15
LED12

+ S16
+ +

LED13 LED14 LED15 LED16


PWB:6870A10001A
ASM:6711A20005E
Group Number 0 + S15 S18

ON KSDO4H
Master Mode LED17

L1 2 3 4
S19

All the connections are to be done as shown above.


VCC
A and B are the communication lines for the indoor and GND
CENTRAL
C and D are the communication lines for the Central Control. CONTROL
C
UNIT
Use two shield lines for C/D connecting line.(Earth the shield line) D

Copyright ©2007 LG Electronics. Inc. All right reserved. - 115 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

■ 2 OR MORE SIMPLE CENTRAL CONTROL CONNECTION


INDOOR UNIT 1

INDOOR UNIT 2

OUTDOOR INDOOR UNIT 3


MAIN PCB INDOOR UNIT 4
<Group Number 0>
INDOOR UNIT 5

INDOOR UNIT 6 Vcc GND C D

BUS
B
BUS
A S1
CN-POWER

LED2
S2
L
CN-POWER
GND

CN-COM A
S4
CN-COM B
Master DIP SWITCH
LED3 LED4

GND IC1P
+
S5
+
S6
+ + S3

LED5 LED7 LED8 TX1

+10V
+

LED9
S9
+

LED10
S10
+

LED11
S11

LED12
S12

S16
1. Adhere the PI485 Module(For connecting central control) to the Control Box.
S14 + S15 +
+ +

LED13 LED14 LED15


PWB:6870A10001A
LED16
2. Connect the PI485 Module to central control.
D C GND VCC
ASM:6711A20005E
S15 S18

3. In the case of connecting two more than central control, set the Master/Slave mode
+

LED17 ON KSDO4H

L1 2 3 4

Outdoor unit 1 S19

Master Mode Group Number 0


and then connect each communication lines(C,D) <Refer to above fig>.
*Special purcharse: Central control(P/No.:4995A20105F),
INDOOR UNIT 1
PI485 Module(PNF-P14A0M)
INDOOR UNIT 2 * It can be added to 15 Central controls for the slave control.

OUTDOOR INDOOR UNIT 3


MAIN PCB INDOOR UNIT 4 Note
INDOOR UNIT 5 <Group Number 1>

BUS
INDOOR UNIT 6 Vcc GND C D 001
B CN-POWER
GND

BUS
A S1
CN-POWER

LED2
S2

LED3
L

LED4
CN-COM A
S4
CN-COM B

Slave DIP SWITCH


Group No.
GND IC1P
+
S5
+
S6
+ + S3

LED5 LED7 LED8 TX1

+10V +
S9
+
S10
+
S11 S12
Indoor No.
LED9 LED10 LED11 LED12

S14 S15 S16


+ + + +

LED13 LED15 LED16

D C GND VCC
LED14
PWB:6870A10001A
ASM:6711A20005E
S15 S18
+

LED17 ON KSDO4H

Outdoor unit 2 L1 2 3
S19
4

Master Mode Group Number 0

PI485 setting method(LG Aircon Network unit)

Selection of product Selection of network type


unit type

ON KS DO 4H

L1 2 3 4

■ Settings method of TPS Inverter Multi Type


ON KS DO 4H
1 ON + All OFF : Connection of "TPS Inverter Multi Connection + General Central
L1 2 3 4 Controller" Case.

ON KS DO 4H
1,4 ON + All OFF : Connection of "TPS Inverter Multi Connection +
L1 2 3 4
Central Controller applied 「LGAP」" Case.

* LGAP : LG Air conditioners Protocol

• Function of LG Network
- It is possible to connect the network of LG air conditioners and to connect various contents of the network
system, which is simple, deluxe and PC central control.
- Please refer to "LG Control System Manual" about the detail functions and the products possible to network.
- As the Interface for networking, PNF-P14A0M/R/C is applied.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 116 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Indoor Unit Address setting Method

Using Wired Remocon 1. Press 13(program) and 16(set and clear) key more
than 3 second then "Address Setting Mode" starts.
2. Set the address of indoor unit by using "Temperature
setting" key.
■ Range of address : 00 ~ FF
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION
Room Temp
HI
MED
AUTO Heater Preheat
JET Defrost Humidify 1
LO Filter Out door
Time ZONE 1 2 3 4
Timer Operation unit Program set
On Off
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23

3
17 2 Ex) 3 A
10 Timer Cancel
5
11
12 6
Program Week Holiday
13 4
Plasma
14 Set/Clr
7
15 Hour Min RESET 8 Group Room(Indoor Unit)
16 9 No. No.
18
3. After setting address, press 13(program) and 16(set
Heat Pump Model
and clear) key more than 3 second then "Address
Setting Mode" is finished.

Using Wireless Remocon


1. Address setting Method
Signal transmitter
1) Press 5(Jet Cool) & 13(Reset) key at the same time more
than 3 seconds then
"Address Setting Mode" starts.
2) Set the address of indoor unit by using
"Temperature setting" key.
■ Range of address : 00 ~ FF
5 1
6
Ex) 3 A
3

4
2 10
CANCEL

7 9
ON OFF SET

11 AUTO CLEAN
Group Room(Indoor Unit)
8 16
13 No. No.
12
15
14 3) After address setting, pressing 1(On/Off) key, address
setting is finished. The address that is set is displayed on a
Flip-up door
display window of indoor unit.
(opened) * notice : The mothod of display and time is different
according to indoor unit type.
4) If the remote control is reset, normal mode starts.
2. Address Monitoring
2.
1) Press 6(Chaos Swing) & 13(Reset) key at the same time then "Address Monitoring Mode"
starts.
2) At the address monitoring mode, pressing 1(On/Off) key, The address that is set is displayed
on a display window of indoor unit.
* notice : The mothod of display and time is different according to indoor unit type.
3) If the remote control is reset, normal mode starts.

* Notice : Confirm that wired and wireless remote control are able to select the address or not.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 117 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Test run method


1. Set the wiring of system and indoor unit.
2. Apply power to the setting.
3. Do auto addressing to the outdoor unit.
4. After addressing, initialize the central controller(Manual initialize: Total on + total off + 16 key).
• Cooling: Setting basically(Total On + Total Off + 4 key)
• Heating: Total On + Total Off + 8 key ➡ Red power lamp 'On'
6. Check up On/Off with a related indoor key pressing.

Installation
■ CAUTIONS

Do not install in this area Keep in mind


• Don’t install near elevator, computer, auto- • Don’t operate with wet hands.
matic door. (High noise area).

• Don’t install near high moisture & high oscilla-


tion area.

• Don’t pull the connected wire.

• Don’t install near direct sunlight or heat


source.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 118 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

■ INSTALLATION ORDER
1. Remove upper & lower case. 2. Fixate screw in the holes of the 3. For Dip switch, and Rotary
case bottom. switch setting, refer to the page
“How to Install”.

4. For wiring connection, refer page 5. Adjust the upper case in accor- 6. Check the operation by supply-
“Installation Procedure” dance with back case while ing the power.
assembling as shown in the fig-
ure.

■ LINK OF CONNECTING WIRE


1. First, separate the front case from rear case of controller, connect terminal GND
C, D,Vcc, GND on PCB referring to the following table. Vcc D

Maximum length of connecting wire C

• Between controller and outdoor unit : 220m(25Ω )


• Between controllers : 220m(25Ω )

Out door unit Terminal Block Wire Color Central Control Terminal
GND BLUE GND
Vcc Red Vcc
C Brown C
D Yellow D

2. After attaching the supplied wire to terminal, link the connecting wire.
If necessary, Cut the indicated part of front case to draw the lead wire.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 119 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

■. ROTARY SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL)


The setting of Group Number in the Central Control is done by the rotary switch as shown in the figure below.

It is possible to set 0~15 Group(Total 16 Groups). All the numbers on the rotary switch represent the different
Group Numbers. By changing the knob we can set rotary switch to the group number we want to control. The
above fig. Shows the control of group number “0”. Similarly we can control all the 16 Groups.

■. DIP SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL)


CAUTION
Dip switch is now used only for the setting of master or slave mode.( In the case of two more
than central controls.)
Set one to Master, the others to slave.

Master Mode
Rotary Switch
Dip Switch
ON
OFF Slave Mode

■. ACCEASSORY PARTS
Central control and sub (with wire ass'y) should be purchased as optional.

Central Control(1EA) PI485(PQNFP14A0M)


Wire Assembly 1

Screw(4EA) Wire Assembly 2

Copyright ©2007 LG Electronics. Inc. All right reserved. - 120 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Deluxe Central Control


2.1.1 Summary
Deluxe Central control is a product available for individual and integrated monitoring and control of maximum
256 of TPS Inverter Multi air conditioner systems. Specially, operation status of the individual air conditioner
can be particularly checked. Individual or simultaneous operation of the air conditioner, operation mode, wind
quantity, user locking and temperature setup are also available.

Specially for this system, installation is simple and user's environment is excellent. Central control is available
by a simple manipulation. In addition, this system have the self-battery built-in and can stably operate in spite
of outside disturbance such as temporary power failure. This system has no need of additional peripheral
equipment like UPS (Undisturbed Power System) and AVR to be purchased for stability when composing the
existing PC central control system, and has so attractive advantage in installation costs.

Using the Deluxe Central control enables the management room to setup lock of each air conditioner and
prevent indoor control of the individual air conditioner and restrain the necessary use. In case of releasing the
lock, you may control the system by using the wire/wireless remote control at the place where the individual
air conditioner is installed.

Setup of a weekly schedule is available and detailed schedule of the individual air conditioner can be easily
setup through the GUI. Details of schedule setup can be immediately checked with a graph. This system is a
product to meet energy saving and convenience at the same time at a place like a school by using this sched-
ule function.

Depending on installation environment, location and conditions of use, you can setup groups. With this setup,
more efficient operation at the center is available. Setup without requiring other equipment is available by
using the GUI and change by the consumer is also available after installation.

You can reduce development time to configure special system upon the request by the consumer and conve-
niently this system by using the touch panel.

Where needs from a new customer occur or where purchase of additional air conditioner is done, the Deluxe
Central control can be smoothly installed.

Deluxe Outdoor Unit


Central control CNU
PI485

Outdoor Unit

PI485

Copyright ©2007 LG Electronics. Inc. All right reserved. - 121 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Major Characteristics

Figure 2) Deluxe Central control

1. Individual/Integrated Operation/Monitoring
■ You can identify operation status of the air conditioner, operation mode, wind quantity, wind direction, lock-
ing, temperature setting and error, etc by selecting the installed air conditioner through individual selection,
group selection or all selection. Individual setup and operation of the detailed functions are available.
Therefore, managing with Deluxe Central control installed at the control room at a building where a number
of air conditioners are installed, is a convenient way.

2. Group Management
■ Group management for the installed air conditioners is available. Group can be seperated by their nature,
location and size of each air conditioner which enables convenient use. In addition, allotment of respective
name to the setup group allows further intuitive management.

3. Self-diagnosis Function
■ The air conditioner installed can self-diagnosed its error status and then transmits the result to the central
control. Therefore, a rapid countermeasure against failure of the air conditioner allows easy management
and increases the usage life of air conditioner.

4. Semi-permanent Life / Convenient Maintenance


■ Since the Deluxe Central control is designed for the semi-permanent use, this system can be used semi-
permanently after installation, different from the existing PC or a large central control system requiring a
continuous management due to the life of peripheral and other PC.

5. Management Costs Down


■ In absence of the Central Control System, the manager controls a number of air conditioners. In addition,
even if management was done at the center, there is only function of on/off management at best and thus 2
or 3 building managers were actually required. However, manipulation of all functions can be now done at
a control room for the Deluxe Central control and so a manager can easily control all air conditioners.
Automatic operation is also allowed without a manager, by using schedule function.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 122 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

6. Convenient GUI / Touch Screen


■ Not requires special education for using the Deluxe Central control, conveniently used only by pressing the
buttons on the screen, and its function can be understood with intuitive pictogram. Especially schedule setting
is done by simply by dragging, different from the existing system requiring to press the button by more than
average 30 times to enter a schedule.

7. Schedule Automatic Operation Management / Energy Saving


■ For the Schedule Automatic Operation, weekly setting is available. Enlisting of the schedule exception pro-
cessing schedule (national holiday) is done for a year prevents the air conditioner from an unnecessary oper-
ation of air conditioner, allowing the system to be controlled at the center so that it can be only used for a nec-
essary case and enabling to obtain excellent energy saving effect. Fixed schedule places like elementary
school, middle school, high school and college or university will get its excellent working effect.

8. Power Failure Backup Function / Powerful Stability


■ For the existing Central Control System, additional purchase of expensive UPS equipment in provision for a
temporary power failure must be done in the past but for the Deluxe Central control, since the self-power fail-
ure compensation battery is built-in, power is automatically converted by maximum 2 hours. Therefore, there
is almost no malfunction due to a temporary power failure because stable operation is available.

9. Mobility
■ A wireless radio system may be installed at the Deluxe Central control, it will control the Airconditioners
directly while going around the building with the wireless radio system and its self-battery function (100 m
where there is no obstacle).

10. Convenient Installation


■ This system can be freely fixed to the wall surface because of its small size, light weight and thin thickness. It
can also stood up on the desk by using, its dedicated cradle. It is not subjected to spatial restriction in installa-
tion space and location since this system communicates on the basis of the I-GW and the Ethernet.

11. Stable Date Storage/Backup


■ Setup information is saved as it is, even if no power is supplied then also all data is saved in the built-in flash
memory.

12. Scalability
■ Scalability of the system is easy in case of additionally purchasing equipment since scalable slot such as
USB, Serial (RS-232c), PCMCIA, CF Type is prepared. This system is designed considering sufficient scala-
bility in provision for special request by the customer.

13. Upgrade
■ Additional installation of a new program is available via the CF memory card and the existing program can be
upgraded to a new program. Using such upgrade function always enables to construct a modern type of
Central Control System.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 123 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Figure 3) Deluxe Central control

Table 1) Comparison Between Central control Characteristics

Internet Central control PC Central control Deluxe


Central control
Dedicate PC Non-required Required Non-required
Configuration User S/W User S/W, Engine S/W Main Body of Web Pad
Deluxe Central control
Position of program Download to i-GW Installation Built-in
Max. installation set 256 sets (Less than 128 sets 256 sets1) 256 sets
numbers recommended)
Remote control Available - -
Control & monitoring Available Available Available
Schedule management - Available Available
System setup Available(Configure file Available Available
modification)
System monitoring(overview) - Available Available

User’s lock Available Available Available


Upgrade Available Available Available
Touch screen - - Built-in
Built-in Flash DB (backup) - - Built-in
Wireless LAN (movable) - - Available (option)
Non-interruption device - Separately add Built-in
Requirements Browser supporting JAVA 2)
JVM (provided by MS) -
Life Semi-permanent Peripheral devices & PC life Semi-permanent

1) For the PC central control, installation set numbers may respond up to 1024 sets upon user’s request.
2) JVM (Java Virtual Machine) is basically installed at the Windows but some versions of Window XP may be
manually installed.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 124 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

Major Function of Deluxe Central Control

[ System Control ]
To check general monitor function of the air con central control
system such as selection of group and air conditioner, air
conditioner control monitor function etc.

PQCSW501A0, PQCSW502A0

[ System Monitor ]

To check the ctual time status of all air conditioners.

PQCSW501A0, PQCSW502A0

[ System Set-up ]

To manage the air conditioner through grouping and record setup


of group and installation position, etc.

PQCSW501A0, PQCSW502A0

[ Time Schedule ]

Setup of a weekly schedule for all, group and individual air


conditioner enabled operation of the system. Processing through
enlist of extra schedule for a year is available.

PQCSW502A0

Copyright ©2007 LG Electronics. Inc. All right reserved. - 125 -


LGE Internal Use Only
Only for training and service purposes
Control Devices and Function

System Configuration
Scenario 1 : In case of not using Internet access function

B part A part Product


Control System
Interface

Delux Central CNU


Control PI485

PI485
Cross UTP Cable
(Cross LAN Cable)
RS-485 Cable

PI485

PI485

* CNU: Central control Network interface Unit


PI485: Product Interface unit for IEEE485 transmission.

Main Specifications
1. Control System
- Centralized control of maximum 256 indoor units
- Simple Touch PAD method
- GUI setting considering convenience of use
- Power failure compensation with independent Battery Built-in (Max. 2 hours)

2. CNU
- Combination of maximum 8 outdoor units
- 485 to Ethernet Converter Built-in

3. PI485
- 1 pcs per outdoor units

Note: - GUI(Graphic User Interface) may be changed without any notice, for improvement or options.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 126 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

Disassembly of the parts (Indoor unit)


Indoor unit
1. Split Type Indoor unit

CAUTION: Disconnect the unit


from power supply before making
any checks.
Be sure the power switch is set to
“OFF”.

To remove the Grille from the Chassis.


• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws
• To remove the Grille, pull the lower left and right Screw
side of the grille toward you (slightly tilted) and lift
it straight upward.

1) To remove the sensor, housing connect,


earth conductor & step motor conductor with
sensor holder, Motor, Evaporator & P.C.B.

Motor
Conductor

Power
Conductor
Sensor
Conductor
Earth
Conductor
Step Motor
Conductor

Copyright ©2007 LG Electronics. Inc. All right reserved. - 127 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

2) To remove the Control Box.


• Remove securing screws.
• Pull the control box out from the chassis care-
fully.

3) To remove the Discharge Grille.


• Pull the discharge grille out from the chassis
carefully.

4) To remove the Evaporator.


• Remove screws securing the evaporator and
the holder eva.

• Unhook the tab on the right inside of the chas-


sis at the same time, slightly pull the evapora-
tor toward you until the tab is clear of the slot.

5) To remove the Cross-Flow Fan


• Loosen the screw securing the cross-flow fan
to the fan motor (do not remove).
• Lift up the right side of the cross-flow fan and
the fan motor, separate the fan motor from the
cross-flow fan.

• Remove the left end of the cross-flow fan from


the self-aligning bearing.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 128 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

2. Art Cool Type Indoor Unit

CAUTION: Disconnect the unit from


power supply before making any
checks.
Be sure the power switch is set to
“OFF”.

1. To remove the Grille from the Chassis.


- Pull the grille bottom, the remove 2 securing screws.
- Lift the both lower parts of panel front.
Panel Front
- After pull down this panel a bit, separate connecting Connector
wire with product.

Step Motor Connectors


2. To remove the Control Box.
Sensor Connector
- Before removing the control box, be sure to
disconnect the wires from PWB.
- Pull the cover control out from the control box
and disconnect other wires.
- Remove securing screws.
- Pull the control box out from the chassis carefully.

4Way/Fan Connector
Comp Connector
Motor
Power Connector Connector
Power Connector
Comp Connector

Copyright ©2007 LG Electronics. Inc. All right reserved. - 129 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

3) To remove the Evaporator.


- Remove 4 screws securing the evaporator.
- Pull the evaporator out from the chassis carefully.

4) Before removing the Turbo Fan.


- Remove the securing screws from the chassis. Top Cover Air Guide
- Pull the pipe cover, top cover and the air guide.

Pipe Cover

5) To remove the Motor.


- Remove the securing bolt from the motor shaft. Bracket
- Pull the fan out from the motor shaft.
- Remove 4 screws securing motor mount from the Turbo Fan
chassis and lift up the motor mount and the brack-
et.

Bolt Motor Mount

Copyright ©2007 LG Electronics. Inc. All right reserved. - 130 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

3. Art Cool Deluxe Type Indoor Unit(SZ,SU,S3)

CAUTION: Disconnect the unit from


power supply before making any
checks.
Be sure the power switch is set to
“OFF”.

To remove the Grille from the Chassis.


• Hold up Inlet Grille Horizentally.
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.
• To seperate connecter assembly and than to
remove Inlet Grille assembly.

1) Before removing the control box, be sure to


take out the wire screwed at the other end.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 131 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

4. Art Cool Deluxe Type Indoor Unit(SE)

CAUTION: Disconnect the unit from


power supply before making any
checks.
Be sure the power switch is set to
“OFF”.

To remove the Grille from the Chassis.


• Hold up Inlet Grille Horizentally.
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.
• To seperate connecter assembly and than to
remove Inlet Grille assembly.

1) Before removing the control box, be sure to


take out the wire screwed at the other end.

Earth
Conductor

Copyright ©2007 LG Electronics. Inc. All right reserved. - 132 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

2) To remove the Control Box.


• Remove securing screws.
• Pull the control box out from the chassis careful-
ly.

3) To remove the Discharge Grille.


• Unhook the discharge grille and pull the dis-
charge grille out from the chassis carefully.

4) To remove the Evaporator.


• Remove 3 screws securing the evaporator(at the
left 2EA in the Eva Holder, at the right 1EA).

Copyright ©2007 LG Electronics. Inc. All right reserved. - 133 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

• Unhook the tab on the right inside of the chassis


at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot.

5) To remove the Motor Cover


• Remove 2 securing screw.
• Pull the motor cover out from the chassis
carefully.

Motor cover

6) To remove the Cross-Flow Fan


• Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
• Lift up the right side of the cross-flow fan and the
fan motor, separate the fan motor from the
cross-flow fan.

• Remove the left end of the cross-flow fan from


the self-aligning bearing.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 134 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

3. CVT Type - VB chassis


Warning : Disconnect the unit from power
supply before making any checks.
Be sure the power switch is set to “OFF”.

1. Remove the air filter. R

• Pull the inlet grille slightly toward you.


• Pull out the air filter. (2 pieces)

Inlet Grille

2. Remove the girlle from chassis


• Remove the screws securing the side plate and
push to the bottom-side.
• Unhook the hanger from the hanger screw at the
left and the right side.
• Pick out the inlet grille. R

4 3

Hanger

Hanger
Screw 2

3. Remove the lower air guide


• Remove a screw of both side fixing "barrier air-
guide".
• Remove the screws of both sides of the lower
air-guide.
• Remove the lower air-guide toward “arrow mark” R

by turning upwards as shown in figure.

Barrier Air guide

Lower Air guide

Copyright ©2007 LG Electronics. Inc. All right reserved. - 135 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

VE chassis
Warning :
Disconnect the unit from power supply before making
any checks.
Be sure the power switch is set to “OFF”.

To remove the Grille from the Chassis.


• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws.
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.

1. Before removing the control box, be sure to


take out the wire screwed at the other end.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 136 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

2. To remove the Control Box.


• Remove securing screws.
• Pull the control box out from the chassis
carefully.

3. To remove the Discharge Grille.


• Unhook the discharge grille and pull the
discharge grille out from the chassis carefully.

4. To remove the Evaporator.


• Remove 3 screws securing the evaporator(at the
left 2EA in the Eva Holder, at the right 1EA).

Caution label
When repair, do not damage the
Caution label.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 137 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

• Unhook the tab on the right inside of the chassis


at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot.

5. To remove the Motor Cover


• Remove 2 securing screw.
• Pull the motor cover out from the chassis
carefully.

6. To remove the Cross-Flow Fan


• Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
• Lift up the right side of the cross-flow fan and the
fan motor, separate the fan motor from the
cross-flow fan.

• Remove the left end of the cross-flow fan from


the self-aligning bearing.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 138 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

4. Remove air guide upper, crossflow fan and


motor.
• Remove the screws of both sides and center
securing the upper air-guide.
• Remove 2 screws fastening the bracket of door
switch. Door
Switch
R

• Remove a bearing assembly by removing a


screw and the bearing cover.
• Remove 4 screws securing the motor cover.
• Loosen the screw securing the crossflow fan to
the fan motor shaft. (do not remove)
• Remove the crossflow fan by sliding it out from Bearing Bearing
Cover
the shaft of fan motor.
Motor R

Cover

5. Remove the control box Assembly.


• Disconnect the step motor connector, fan motor
connector, display PCB connector, thermistor
connector and door switch connector from the
main PCB.
• If necessary, disconnect power supply cord and
connecting cable from the terminal block and R

remove the cord clamp screw.


• Remove 2 screws securing the control box and
pick out the control box carefully.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 139 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

6. Remove the front panel. Diffuser frame


• Remove the screws of both sides fixing the front Diffuser
panel. frame
• Push the upper side of front panel strongly to pull Hook
out the front panel from the inner hook of diffuser
frame. Front
Panel
• Pull down the front panel carefully not so as to Front
harm the display PCB wires and thermistor Panel
wires. R

7. Remove the diffuser assembly.


• Remove the screws of both side of diffuser
assembly. (4 pieces) Diffuser
frame
• Push the upper side of cabinet strongly to pull
Hook
out the inner hook of diffuser frame from the cab-
Cabinet
inet hole.
• Take up the diffuser frame carefully not so as to
harm the display PCB wires and the step motor
wires.

8. Remove display PCB assembly.


• Remove the screws at the both side of display
cover.
• If necessary, disconnect the display PCB con-
nector from PCB assembly.
• Remove 2 screws of PCB assembly. Display Cover

Copyright ©2007 LG Electronics. Inc. All right reserved. - 140 -


LGE Internal Use Only
Only for training and service purposes
Disassembly of the parts

9. Remove the vane-upper, vane-lower and step


motor. Step Motor
• Remove 2 screws securing the step motor
assembly and pull it out from the vanes carefully. Vane Supporter
• Unhook the vanes from the vane supporter and
remove the upper vane and lower vane by
pulling the center of vanes with care.

Lower Vane Upper Vane

10. Remove the drain pan assembly.


• Remove the both side of screws. (4 pieces)
• Pull out the drain pan assembly.
• Be careful not to harm to the EPS packing of
drain pan and the tubings of evaporator.

11. Remove the evaporator.


EVA. Barrier-L
• Remove the screws of both sides securing the
EVA barrier-R/L on the side cabinet.
• Remove the screws which fasten the barrier on
the evaporator and take out the barrier assem-
bly.
• Remove the evaporator assembly by sliding
toward arrow mark. (As shown in figure)
Side Cabinet

EVA. Barrier-R

Copyright ©2007 LG Electronics. Inc. All right reserved. - 141 -


LGE Internal Use Only
Only for training and service purposes
LGE Internal Use Only
5V SLIDE S/W
R04F,10K R02F,10K REMO 1
2
R03F,1K
3
R01F,1K
4
DISPLAY
MICOM DC 5V 1 1 7 7 GND
R16G,6.8K
Q13G
GMS81516 R15G,6.8K REMOCON 2 2 6 6 Vout
KTA1270Y LED4
5V 1 Vdd RD R30 64 3 3 5 5 Vcc
LED3 PRE AMP
R02H R04H R16H R15H R14H R13H R12H R11H C01M 2 MP Wt R31 63 R14G,6.8K
4 4 4 4 ASSY
0.01 R13G,6.8K Q12G LED2 TFMS-
3 AVss R/W R32 62 5 5 3 3 2380B

C02F,0.01/50V

C01F,0.01/50V
12.1K 6.2K 12.1K 12.1K 12.1K 12.1K 12.1K 12.1K 50V KTA1270Y
LED1
1% 1% 4 AVref C R33 61 6 6 2 2
C02L
R12G,6.8K
5 R67/AN7 SYNC R34 60 R11G,,6.8K Q11G 7 7 1 1
KRA1270Y
6 R66/AN6 BRK R35 59 CN-DISP1
220uF
7 R65/AN5 BRQ R36 58 IC02M 10V
CN-TH
8 R64/AN4 HALT R37 57 KID65004AP CN-DISP2
PIPE-TH R06G,220
1 1 9 R63/AN3 D0 R00 56 1 16 1 1
R01G,220
2 15
2 2 10 R62/AN2 D1 R01 55 2 2
R03H,1K R07G,220
3 14
3 3 11 R61/AN1 D2 R02 54 3 3
R01H,1K R02G,220
4 13
4 4 12 R60/AN0 D3 R03 53 4 4
ROOM-TH R04G,220
C01H C02H 5 12
13 R57/PWM1 D4 R04 52 5 5
R05G,220
6 11
0.01 14 R56/PWM0 D5 R05 51 6 6
50V R03G,220
7 10
CN-U/D 15 R55/BUZ D6 R06 50 7 7
RD EEPROM 8 9
DC 5V
1 1 DC 12V 10 9 OP6 OP5 OP4 OP3 OP2 OP1 16 R54/WDTO D7 R07 49 8 8
DC12V
OR 11 8
XXXK XXXK XXXK XXXK XXXK XXXK
2 2 17 R53/Srdy A0 R10 48 S 1 8 VCC DC 5V
YL
7 DU
3 3 12 7 C 2
18 R52/Sclk A1 R11 47 DC 12V 1 1
PK
D 3 6 ORG
13 6
4 4 R51/Sout A2 R12 46 2 2

R01T,10K

R02T,10K

R03T,10K

R04T,10K

R05T,10K
19 DC 5V
BL Q 4 5 Vss
14 5
5 5 20 R50/Sin A3 R13 45 3 3
STEP MOTOR

- 142 -
UP/DOWN 15 4
21 R47/T30 A4 R14 44 4 4
16 3
22 R46/T10 A5 R15 43 5 5
17 2
23 R45/EC2 A6 R16 42 6 6
18 1 24 R44/EC0 A7 R17 41 7 7
IC01M TX 25 R43/INT3 A8 R20 40 8 8
Schematic Diagram

KID65084AP
RX 26 R42/INT2 A10 R21 39 9 9
DC 12V
27 R41/INT1 A11 R22 38 CN-SUB
R02E,20 SSR-MOTOR
28 R40/INT0 A12 R23 37
R02A,4.7K R01A,1K
Q01M
5V 29 RESET' A13 R24 36
C01A KRC107M
R03A,100 0.01 XIN A14 R25 35
Electronic Control Device

KIA7036P 30

Copyright ©2007 LG Electronics. Inc. All right reserved.


50V
R01B,1M
BZ01E R01E,1K IC01A C02A +
10uF/50V
31 XOUT A15 R26 34
32 VSS A16 R27 33
R02L,10K OSC01B
5V CST-8.00MTW
IC01K(TLP621) D01K
1SR139-600
R01L,1K RX
R02K,1K 3 2
REMOCON C01K R03K ZNR01M
0.001 INR14D471K
R01K 1K ZNR01K
25V 4 1
C01L 10K DC 5V 14D271
680pF IC02K(TLP627) CN-FAN
50V NF01M NF01M
2 3 3 3
TX
INDOOR

Only for training and service purposes


1 4 2 2
R02C,4.7K R01C,1K SSR-MOTOR FAN
5V R04K R01M,120,1/2W C01M,0.1,AC275V
Q01K 680 R05K MOTOR
R03C,20K 25K,3W,1% 1 1
R04C,10K KRC102M
FREQUENCY C01C
M Q01C 0.01
R05C C02C KTC3198Y 25V IC02D
4.7K 0.015 O I D02K
50V DC 5V 7805 1SR139-600
+ COM
3 3
C06D C05D FUSE
C01J NF01J
0.01 470uF 0.1, AC275V 250V/T2A
Schematic Diagram

LIVE
25V 16V FREQUENCY 2 2
D02D-05D

1. Indoor Unit
D01D 1SR139-600 ZNR01J NEUTRAL
IC01D INR14D471K 1 1

1) Split Type
1SR139-600 SVC561D-14A
O I
DC 12V 7812 CN-POWER
+ +
C04D C03D C02D C01D
0.01 470uF 0.1 2200uF
25V 25V 50V 35V
POWER TRANS
6171AQ3124C
Schematic Diagram

2) Art Cool Type

Copyright ©2007 LG Electronics. Inc. All right reserved. - 143 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

3) Art Cool Deluxe Type


• A/C MOTOR

Copyright ©2007 LG Electronics. Inc. All right reserved. - 144 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

3) Art Cool Deluxe Type


• BLDC MOTOR

Copyright ©2007 LG Electronics. Inc. All right reserved. - 145 -


LGE Internal Use Only
Only for training and service purposes
LGE Internal Use Only
C05D
DC310V 681 12V R11K C11K
NF01J R01J D01D IC03D C09D IC11K(TLP621)
CN-POWER 250V/ ZNR01J 22mH/3A 10K 102
RX
1M,1/2W 1N4007 S/Trans L01D KID78L05BP 220uF/50V M_RTX Multi_RX
LIVE T3.15A,3A INR14D561K 1 2 3
1 2 6,7 I O R12K,1K
2 2 7805 5V R13K
D03D 3.3uH 1.5K 1 4
NTC01D G DC 5V
ZD01D UF5402 DC 5V
NF 10D-9 R04D C10D M_RTX
P6KE200A C06D C08D
NEUTRAL 3 4 3 470uF/35V
39
104 103 D11K
1SR139-400
R16K
1 1 AC_N 4,5 D12K 10K
C03J
C01J C02J 1SR139-400 3 2 TX Multi_TX
10nF D02D C07D C11D
100nF 100nF C01D D IC02D(TLP521) 223/1KV
275V UF4005 330uF/35V 4 1 Q11K
SIGNAL 275V 275V 10uF/ 5 EN DC 5V
400V 4 C12D R14K
3 3 M_RTX
IC01D
TNY R15K IC12K(TLP627) KRC104M
R03D 103/1KV 1K
RY-COMP 255P 82K/3W
TNY255P BP
2 1 150
AC_L S
C03D
3,7,8 ZD02D
103
11V
D01K L01K
CN-OUT C04D
RY-OUTFAN IC02M DAN212K 100nH
RY-OUTFAN 103/250VA
DC 12V KID65004AF IC02M 12V
1 1 5V
DC 12V KID65004AF DC 12V CN-REMO
RY-4WAY Q03K
RY-4WAY DC12V
3 3 STEP M STEP M5 HEATER KRC104M 3 3
P75 R02K L03K Signal
RY-HEATER RY-HEATER 1 P76 64 유선_TX 2 2
4.7K GND
5 5 MED P74 4WAY 1 1
2 P77 63 Q01K L02K
CN-D/PUMP D/PUMP OUTFAN KRA104M C05K
1 1
3 P00 P73 62 C04K C06K
Drain
Motor
STEP M STEP M2 A/C 104 103
3 3 4 P01 P72 61 R07H R05H R03H 12V
COMP 12.1K 12.1K 12.1K 5V
CN-LOUVER
RY-D/PUMP STEP M STEP M3 C03K
1% 1% 1%
5 P02 P71 60 5V
R01K
102
1 1 LOUVER STEP M4 STEP M R08H R06H R04H R02H 1K
Louver
Motor 6 P03 P70 59 12.1K 12.1K 12.1K 6.2K R01H
유선_RX
3 3
HIGH 1% 1% 1% 1% 12.1K
1% D02K
RY-LOUV 7 P04 VDD 58 5V
DAN212K
CN-MOTOR1 LOW OPTION6 C01K C02K Q04K
1 1 8 P05 (AIN7)/P67 57 102 102 KRA104M
Q02K
壤 IC01M OPTION5
2 2 KID65004AF 9 P06 (AIN6)/P66 56 CN-PIPE KRC104M
FAN RY-L DC 12V OPTION4

- 146 -
MOTOR 3 3 10 P07 (AIN5)/P65 55
RY-M OPTION3
FREQ 5V 5V
11 P10(INT0) (AIN4)/P64 54

1
4 4 50/60Hz
RY-H REMO OPTION2 R03C R06C

3
CN-MOTOR2
NF01M
SSR
NF01M
REMO
C02L
12 P11(INT1) (AIN3)/P63 53 10K 10K
PIPE TH IC01C
1 1 681 R04C
BZ01E
13 P12(INT2/TC1) (AIN2)/P62 52 AC_L 4.7K 50/60Hz

1
FAN 2 2 ROOM TH Q01C
MOTOR
3 3
ZNR01M
R02E 14 P13(DVO) (AIN1)/P61 51 CN-ROOM
R02C
1K R05C C01C
20 PHASE OPTION 1
15 P14(PPG) (AIN0)/P60 50 AC_N
1K 103
R01E EERROM
R02A 10K Q CN_M C R01C
1K 8 1
P15(TC2) VARF
16 49 5V
S
5V VCC 200K/2W
5V
D
12V 1 1 12V
R01A 1K 7 2 VASS C01U
1 3 DU C
17 P16 48 GND
103
KIA7036P
SB3 OR6 OR5 OR4 OR3 OR2 OR1 C02H C01H 5V 2 2 5V
+ 3 C
IC01A 2 C02A 6 ORG D
18 P17 P54 47 S_B3 103 103
C01A

Copyright ©2007 LG Electronics. Inc. All right reserved.


3.6V 3.3uF 102 SB2 R01U GND 3 3 GND
5 VSS Q 4
S C02U
/50V 19 P20(INT5/STOP) P53 46 S_B2 10K
103
5V
SB1
5V 4 4 PLC_SEL
DISPLAY R01L
GND
20 TEST (PWM/PDO)/P52 45 S_B1
SB0 Multi_TX 5 5 Multi_TX
10K
GND 1 1 NC 21 P21(XTIN) (INT4/TC4)/P51 44 S_B0
R02L 1K CC RX Multi_RX 6 6 Multi_RX
Vout 중앙_RX
2 2 REMO NC 22 P22(XTOUT) (INT3/TC3)/P50 43
R03L 1K CC TX
Vcc LED1 RESET 중앙_TX GND 1 1 GND
3 3 23 RESET (SO2)/P47 42
R04L 1K XIN
LED2
PRE AMP 4 4 R01B 24 XIN (SI2)/P46 41 유선_RX 5V 2 2 5V
TFMS-2380B
R05L 1K 1.0M XOUT
LED3
5 5 25 XOUT (SCK2)/P45 40 유선_TX 12V 3 3 12V
LED4 R06L 1K OSC01B SO1/PLC
Force VSS 4 4

Only for training and service purposes


SW
6 6 8.00MHZ 26 (SO1)/P44 39 SO1
LED1 SI1/MULTI TX
7 7 5V
27 P30 (SI1)/P43 38 5 5 SI1
LED2 SCK1/MULTI RX
CN-DISP P31 (SCK)/P42 6 6
28 37 SCK1
LED3
5V
29 P32 NC 36 7 7 CS0
CN-LOUVER R02F R01F LED4
30 P33 NC 35 8 8 CS1
1K 1K
LOUVER
1 1
31 P34 NC 34
Schematic Diagram

3 3
FLOAT
NC
CN_ZONE
32 P35 33
4) Duct Type

CN-FLOAT
CSO
C02F C01F
1 1 103 103
2 2 CSI
Schematic Diagram

SLIM DUCT(B1,B2)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 147 -


LGE Internal Use Only
Only for training and service purposes
1
LEV CN-LEV
2 SW-HIGH
6 6 DC12V MICOM 20K 40K
3 R14G R15G
5 5
MN101C30A QFP64 12.1K, 1% 3 9 8 7 4
R21H A 6
B 5 10K
4 PA0/AN0 5V 80K
4 4 62 2 C 4 5 R16G
37 P60/AO 12.1K, 1% R13G
D 3
R22H 2
E
3 3 PA1/AN1 63 1 F 0 1 6
38 P61/A1 12.1K, 1%
2 2 R23H
39 P62/A2 PA2/AN2 64 12.1K

WH YL OR BL BR RD
1 1 R12G

40 P63/A3 5V
STEPPING MOTOR (UP/DOWN)
9 8 SW-LOW
12V 61 Vref-
CN-U/D2 OR1H OR2H OR3H
F1 F2 F3 20K 40K
BL IC01M 1 R08G R09G
5 5 PA3/AN3 R11G
3 9 8 7 4
1K A 6
PK B 5 10K CN-TH2
4 4 PA4/AN4 2 80K R10G
7 R05G 2 C 4 5
D/PUMP R07G 3 3
YL 41 P64/A4 1K D 3
3 3 C01G 5V
C02G E 2 PIPE-OUT_TH
6 103 1 F 0 1 6
OR4H 103
Schematic Diagram

2 2
OR COMP 42 P65/A5
2 2
R03H R02H R01H 1 1
5
FAN 43 P66/A6 12.1K 6.2K 6.2K 12.1K
R06G 1% 1% CN-TH1 ROOM-TH
RD OR5H 1%
1 1 4
12V 4WAY 44 P67/A7 1K R04H 4 4
STEPPING MOTOR (UP/DOWN) 3
3 PA5/AN5 1K R05H 3 3
INDOOR FAN 47 P72/A10
CN-U/D1 PA6/AN6 4 2 2
2 PIPE-TH
BL 48 P73/A11 1K R06H
5) Convertible Type

5 5 1 1
1 PA7/AN7 5 5V
PK OR6H
4 4 49 P74/A12 C03H C02H C01H
9 8
R01P 103 103 103
YL
3 3 12V 10K 8 1
100nH DAN212K
OR IC02M
2 2 MODE/WC L01K D03K
SBT1/P05 7 2

Only for training and service purposes


19
SCL 12V
R02E,20 SBI1/P04 18 6 3
RD BZ01E SDA 5V 4.2K
1 1 12V 20 BUZZER/P06 R09K CN-REMO
PKM13EPY-4002 R01E 5 4
SBO1/P03 17 C11K C12K
3 3
1K L03K
EEPROM 104 103
2 2
R01F,1K IC 1
Q01K Q03K
DISPLAY P54 36 Force KRA104M KRC104M
1 1
7 L02K
50 P75/A13 R02F 12V CN_INSTALL
C01F 5V
6 103 10K C10K 1 1
GND 1 1 51 P76/A14 R08K Q02K 102
1K
5V KRC104M 3 3
Vout HVB OUT 5
2 2 RECEIVER 52 P77/A15
25 D02K
LED4 R04G,330,1/4W TM3IO/P13 C08K Q04K
4 102
DAN212K 5V
Vcc 3 3 57 P83/D3 KRA104M R07F R05F 1 1
1K 1K
LED3 R03G,330,1/4W TM2IO/P12 24 C09K
PRE AMP 3 102 2 2
4 4 58 P82/D2
ASSY R08F,1K
LED2 R02G,330,1/4W 30 3 3
TFMS- 5 5 2 IRQ3/P23
2380B 59 P81/D1
R06F,1K 4 4
LED1 R01G,330,1/4W 1
6 6 60 P80/D0 IRQ2/P22 29
5V
9 8

Copyright ©2007 LG Electronics. Inc. All right reserved.


C03F C04F
7 7 DC 5V 12V IRQ1/P21 28 R07D
+ 12K CN-DOOR
C02L IC03M
SEL 16 P02/SBT0
8 8 FORCE IRQ0/P20 27
4.7
50V Rx Q01C INT
15 P01/SBI0 KTC3198-Y
2SC5343 R08D
Tx 14 P00/SBO0 56K
CN-CC 5V
DC 5V
R01L
D7/P87 53 R02L,1K 5.1K
1 1 1 DC 12V
receiver
R02A,4.7K C01L
R01A
5V R04F,1K 680pF/50V
1 1 2 2 2 DC 5V
1K 1 3 3
3 3.6V
NRST/P27 21 IC01A CN-FLOAT
2 2 3 3 3 R03A 2 2 2
C01A C02F,103 R03F,10K

R06T,10K
R05T,10K
R04T,10K
R03T,10K
R02T,10K
R01T,10K
10/ 100
Telecontrol 4 4 32 P50/NWE 50V 5V
1 1
3 3 4
OSC2 8
5 5 5 33 P51/NRE OSC01B
OSC1 9 1M
6 6 6 34 P52/NCS R01B
Vref+ 6 5V
7 7 7 35 P53/A16
Vdd 7

- 148 -
8 8 8 22 P10/TMOIO
C01Z
103
9 9 9 23 P11/TM1IO Vss 10
12,26,31,45,46
NU 54~56 XI 11
MMOD 13

Option
CN-HVB

3 3

HVB 2 2

1 1
JP1
SEL JP3
4WAY
3 3
2 1
INDOOR FAN
2 2
INT JP4
1 1 HVB OUT Tx
CN-CONT
JP2
COMP JP5 FAN
3 3
5V
2 1 2 2 JP6
12V Rx
1 1 12V
CN-12V DC PART
D/PUMP
CN-ACDC 1 2 3 4 5 6 7 8 9 10

IC01J R03J
CN-ACDC 1 2 3 4 5 6 7 8 9 10 TLP762JF 680
1
1/2W NF02J
12V 12V 6
D/PUMP R04J 2
AC PART FOR NORMAL 560 ZNR02J
FAN 4
12V RY-FAN 1/4W 3216 3 TVR10561
T2

FAN
4WAY RY-4WAY INDOOR FAN TR01J
5V 4WAY SM1L43
INDOOR FAN RY-COMP INDOOR
COMP COMP FAN
T1

INT RY-D/PUMP CN-MOTOR MOTOR


D/PUMP SH-CAPACITOR
IC04D R02J 3 3
C03D
NF02J 100,1/2W
S78DL05L 1W L1 681 2 2
12V 1K/1W
ZBF503D D05D 1 1
O I SMPS 1N4007
5V 7805
D07D NTC SCK-102
C07D C06D UG2D 5V
R03D + R01J
104 330 39 BD01D 1 1 Drain
SD01D 120, 1/2W RY-D/PUMP CN-D/PUMP
50V 25V SD 1/8W 2012 C04D R05D DF08M Motor
STO2D-200 R04D 300K 3 4 G5N-1A(G5NB-1A) 3 3
470/35V/SD 27k 1/4W C03J
+ C09D C08D 1/8W 2012 3216 100nF RY-FAN
+ T-BLOCK OUTDOOR
220 C01D 275V/436D G5N-1A(G5NB-1A)
103 3 4
5 5 FAN MOTOR
10V SD 50V D 5 15uF INT RY-4WAY 4
1 4 4 1 G5N-1A(G5NB-1A) 4-WAY
450V/SG 3 4
R02D IC02D EN 4 4 4
TLP181(V4 BL) 3
20K D08D R06D
2 3 BP 1 LL4148 300K NF01J
IC01D 2 15mH/1A FUSE
3 1/4W 3216 250V/T2A
TNY266P IC03D RY-COMP
ZD02D C02D 2 2 1
C05D TLP181(V4 BL) G4A-1A-E-LG 2(N) COMPRESSOR
BZX55C11 104 S 2,3,7,8
472M 4 1 1
1(L) CN-POWER
DC LOW DC HIGH DC HIGH DC LOW DC HIGH 3
VOLTAGE GND VOLTAGE GND VOLTAGE GND VOLTAGE GND VOLTAGE GND ZNR01J
L AC220~240V
TVR10561
1 1 50/60Hz
C02J C01J N
METAL FILM CN-TAB1
METAL FILM
47nM/275V/435D 100nM/275V/436D

LGE Internal Use Only


Schematic Diagram

LGE Internal Use Only


12V
+5V 20 1
R01E,1K R03E,0K 100uF/25V
1 20 5V PTC_HEATER AC
HVB_S B0
19 2
A7 A7 SMW-200-8P C04H 5V
IC1 CN_PTC2 C03H A0
2 19
B0 SUB_PCB
R02E
B1 A6 CN_PTC1 IC1
A6 C04H 47uF/25V
1M C01E 18 3 A1 B1
4 4 104 12V 8 8 12V 3 18
IC02M COMP
74HC574

3 3
B2 A5 A5
KID65004AF 17 4 C05H C01H C02H

74HC574
A2 B2
2 2 DC12V 4WAY 5V 7 7 5V 4 17 IC3
B3 A4 A4
1 1 10 B
7 SM22 16 5
104*2 104*2 A3 B3 KID65004
12V
OUTFAN 6 6 5 16
B4 A3 A3
11 6 SM23 15 6 A0 A0 A4 B4 4 13
SMW-250-04P B
D/PUMP 5 5 6 15
B5 A2 A2 RY-HEATER1
CN_HVB 12 B
5 A/C_OUT 14 7 A1 A1 A5 B5 5 12
A/C_OUT 4 4 7 14
B6 A1 A1 RY-HEATER2
13 B
4 D/PUMP 13 8 A2 A2 A6 B6 6 11
3 3 8 13
CN-D/PUMP B7 A0 A0 RY-HEATER3
35328-0210-NA(molex)
14 B
3 OUTFAN 12 9 A3 A3 A7 B7 7 10
2 2 9 12
GND +5V RY-HEATER4
15 B
2 4WAY 11 10
CS1 R01H GND
Drain
1 1 1 1 10K 10 11 R02H
CS1
Q01H
Motor
3 3
16 1 COMP
COMP 1K
C01M/102 KRA104M
CS4
RY-D/PUMP 9 8
NF01J
250V/ R10M CN_LEFT_SW CN_RIGHT_SW
+5V 20 1 A0 T3.15A,3A 22mH/3A
IC01K(TLP181-BL) +5V 1 2 1M
R03K,1K OUT_RX AC(N)
R01M 10K 1 1 1 1 1
2 3
C01K SM23 B0 A7 A7
R02K C03K
19 2 A1
1K 103
1.5K 104
1 4
DC 5V
R01K
10K
102
12V 9 A 8 IC2 ZNR01D C01D NF C01D
C01J R02M 10K 2 2 2 2
10 7 SM22 B1 A6 A6
10nF
275VAC DELET A
SM43 18 3 A2 INR14D561K 3 4
3 2 OUT_TX AC(L) 2
(DIP) R05K D01K R14K
CN-LEV 11 SM10 R03M 10K
74HC574

15K,3W 6 SM21 B2 A5 A5 3 3 3 3
WH YL OR BL BR RD

BZX55C68 680 A
4 1
17 4 A3 CN-GRIL_LEFT FP_L_UP
D02K
68V/1W
IC02K(TLP181-BL) 6 6 12V 12 A 5 SM11 NF01J
Q04 R04M 10K 1 1 4 4 4 4
1SR139-600 KRC102S
5 5 SM20 B3 A4 A4 FRONT
1N4007 CHANGE 16 5 A4 PANNEL
UP_DOWN 3 3 FP_L_DOWN
4 4 SM13 B4 A3 A3 R05M 10K
Motor
+5V
15 6 A5 2 2
3 3
R06M 10K 5V
2 2 13 A 4 SM12 SM12 B5 A2 A2
14 7 A6 CN-GRIL_RIGHT FP_R_UP R10H
DC310V 1 1 14 A 3 SM13
R07M 10K NF02J 1K
SM11 B6 A1 A1 1 1 TRB
15 A 2 SM20 13 8 A7 FRONT CS2
R18D
SMW-250-6P R08M 10K
PANNEL
3 3 FP_R_DOWN Q01H
16 A 1 SM21 SM10 B7 A0 A0 UP_DOWN
200K,2W R20D D01D
L2
12uH(DIP)
+15V
12 9 CS1 Motor
2 2 KRA104M
110K,2W SMPS(6170A90026A) UG2D 12V
C09M C08M C07M C06M IC03M R09H
R09M 10K R01H~R04H R05H~R06H
103 103 103 103 KID650004AF GND C07H 10K
C02D
470uF
+ R06D
1K
+ C05D
220uF
11 10 CS2 103 10K*4 1K*4
C19D 35V 1/2W 35V
Q01D R10M 10K
103,630V C08H C03H~C06H
KRC104S D03D L1 IC04D CS3 103
D08D
UG2D 12uH(DIP)
S78DL05L,1W(DIP)
5V
C02M/102 CS5 R11M 10K
103*4
1N4937 7805
+ C06D R07D C07D + C08D C04D C03D
+ 1 20 5V
R17D 220uF 104 104 220uF
ZD02D 470
5 D

470uF
25V
1K
1/4W 25V 50V 50V 10V SMW-250-10P +5V 20 1 CS4 220uF/25V A0 IC1 B0
R19D
UZP-11B 4 EN
CN_GRILL 2 19 1 20 5V
CN-UD2 CN-UD1 C05M R12M 10K C06H C22H
5.6K
IC01D
1BP
R21D
103 SM43 B0 A7 A7 C02H A1 B1 IC2
TNY267P 39
DC LOW
STEPPING MOTOR
19 2 CS5 1 1 3 18 IC3 A0
C22D VOLTAGE GND
»óÇÏ ÅäÃⱸ
RD RD 9 8 IC3 12V
C21H
12V 2 19 CS3
2 S 104(DIP) 1 10 10 10 10 12V 12V B R13M 10K

74HC574
6
IC02D R22D
OR OR 10 7 SM42 B1 A6 A6 C07H C01H A2 B2 KID65004
C18D PC-17K1 1K
9 9 9 9 A
SM30 18 3 CS6 2 2 A1 B0
4 3 5V 5V 4 17 3 18

74HC245
104 YL YL 11 SM31 R14M 10K

74HC574
ZD03D
BZX55C11 8 8 8 8 A 6 SM41 B2 A5 A5 12V
17 4 104*2 104*2 A3 B3 A2 B1
DC HIGH
VOLTAGE GND
DC310V
PK PK 12 5 SM32 3 3 5 16 4 17
CY7 7 7 7 7 A 47uF/25V FP_L_UP
BL BL SM40 B3 A4 A4 A0 A0 R14H A4 B4
103 (DIP)
6 6 6 6 13 4 SM33 16 5 A3 B2
AC(COM)
A 4 4 6 15 5 16
4 RD RD 14 3 SM40 B4 A3 A3 A1
5 5 5 5 A SM33 15 6 A1 R13H A5 B5
FP_L_DOWN
B3
A4
CN-POWER
OR
YL
4 4
OR
YL
4 4 15
16
A 2
1
SM41
SM42 SM32 B5
14 7
A2 A2 A2
5 5
A2 R12H A6
7 14
B6
FP_R_UP
A5
6 15
B4
MULTI-V 485 SUB PCB
C01D
3 3 3 3 A 6 6 8 13 7 14
YW396-07AV
3 220UF PK PK IC04M B6 A1 A1 A3
450V 2 2 2 2 SM31 13 8 A3 R11H A7 B7 FP_R_DOWN
B5 5V ISOLATED GROUND PLANE
C02N or
BL BL KID65004AF 7 7 9 12 A6
N/F01N
0.33uF 680UF 1 1 1 1 8 13 7805
(DIP) ZNR01N 275VAC 1K*4 C01Y
11mH/1.5A NTC 400V
SM30 B7 A0 A0 CS1 GND U05Y 104 VR01Y
AC(L) FUSE SVC561D-14A (DIP) DSC8D11M STEPPING MOTOR 12 9 8 8 CS1 10 11 CS2 A7 B6 MAX253
1 250V/T3.15A CN_PN
Á¿ì ÅäÃⱸ 9 12 TRANS01Y D01Y IN GND OUT
1 6
CY3~4 YW-396-03 12V GND CS2 1 8
472M
+ 11 10 9 9 TRB GND B7 SS14 C02Y C03Y
R017D
560K
1 C04M 10 11 2 7 2 5
104 22uF/35V
1/2W 103
C04Y
3 6
CS3 D02Y
ΩÂ˚-±◊¸± SUB PCB
3 3 4 22uF/35V
AC(N) BD01D (DIP)
10 10 CS3 4 5
SS14
2 D3SBA60 C03M/102 CS6
C03N
0.33UF R018D
1M
CY6
332M SMW-200-10P C05Y
275VAC 1/2W
1 8
(DIP) DC310G CN_A5 2
U02Y C07Y 104
7 104
1 1 +5V TX R01Y 6N137
+15V 3 6
0.62K R02Y
2 2 5 5.1K

YW-396-02V
4 U01Y

CN-COMM
SMW-250-07P 3 3 SN65LBC176
2WAY SUB M
OTOR CN-MOTOR1(WH) Q04G
KRA223S
L02Y

- 149 -
4 4 4.7K 1 8 1 8 12uH
RD 1 1 IC05D U03Y
DC 311V R03Y C08Y 2 2 BUS(B)
TLP181-BL 2 7
7 104 2
2 2 C11D 5 5 SEL R07Y 6N137 L01Y
473 4 1 5V 3 6 3 6 12uH
1 1

5V
R04Y BUS(A)
IN DOOR 3 3 630V
D04D CS6 R09H~R14H LED1 0.33K
4 5
(TM) on/off (2012) 4 5 5.1K ZNR01Y
BK 1N4148
3 2
12.1K*6
4 4 KRA223S D06D R08D 1K
FAN Q05G 1N4148
HVB_S 1%
WH 5 5 +5V
MOTOR R02C,20 5 4
BL 6 6 4 1 RX R05Y 6 R06Y
D07D 3
R10D
YL 7 7
R12D
D05D 3 2
1N4148
PWM
(2012) 5V
6N137 7
2 0.62K
4.7K
10K 4.7K 1% 1N4148 R01C

4
ZD01D R09D 1K U04Y 8
1
6.8V C12D IC06D
1K

M24C01-BN6
100UF R11D TLP181-BL CN-FLOAT C03F R01F C06Y

OUT_RX
OUT_TX
C06F
(2012) 104

EERROM
103
25V 5.1K 103 10K R02F
IC07D BZ01C 1K

WR_TX
5 SDA
SCL
WC
1 1

P14(TC4/PDO4/PWM4/PPG4)
R15D TLP181-BL
PKM13EPP-4002

S
RD 1 1 2.7K

8
3 3

6
1 4 5V R03F
2 2 R14D 1K C04F 10K
2 3 H/S1 C02F
103

P13(TC3/PDO3/PWM3)
IN DOOR 3 3 C14D 103 AD_CH13 AD_CH13
BK 4 4
103
R16D
IC08D GT-250-3P-TS
FAN TLP181-BL R04F
2.7K 5V AD_CH12
WH 5 5 1 4 10K

Q
S
MOTOR BL
R13D 1K
6 6 2 3 H/S2 R01G OFF_ON
C15D R02G AD_CH11
YL 10K
C11H 103

P77(AIN17)

P76(AIN16)

P75(AIN15)
103
C12H 103

R30H 10K

R29H 10K

P46(SCK2)
7 7

P41(RxD2)
P42(TxD2)
1K

P12(PPG)

P11(DVO)

P45(SO2)
P10(TC1)
CN-MOTOR2(BL) 3

P44(SI2)
AD_CH10 CN_OPTION
SMW-250-07P 2 SMW-200-11P

P47

P43

P40
C02G PWM AD_CH9
1 1 1 OR11
103
+5V SW2 AD_CH8 2 2 OR10

48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
DISPLAY R01L YFW254-03 3 3 OR9
10K
GND 1 1 4 4 OR8
R02L 1K (INT3/TC2)P15 P74(AIN14) AD_CH12 OR7
Vout
2 2 49 32 OR6 OR7 OR8 OR9 OR10 OR11
5 5
R07L 330,1/6W R03L 1K (PDO5/PWM5/TC5)P16 P73(AIN13) AD_CH11 OR6
LED1 C02L CS4 6 6
Vcc
3 3 LED1
681 50 31 R01H R02H R03H R04H,R05H,R07H,R08H
12.1K*5
FLASH:TMP86FS49FG
R04L 1K CS5 (PDO6/PWM6/PPG6/TC6)P17 P72(AIN12) AD_CH10 12.1K 6.2K 6.2K 7 7 OR5

Copyright ©2007 LG Electronics. Inc. All right reserved.


LED2
PRE AMP
TFMS-2380B
4 4 LED2 51 30 +5V
1% 1% 1% 1%
8 8 OR4
LED3 R05L 1K (SCL)P50 P71(AIN11) AD_CH9
5 5 LED3 LED1 52 29 9 9 OR2
Force LED4 R06L 1K (SDA)P51 P70(AIN10) AD_CH8
6 6 LED4 LED2 53 28 10 10 OR1
SW
P52 P67(AIN07/STOP3) AD_CH7 AD_CH7 11 11
7 7 +5V LED3 54 27
P53 P66(AIN06/STOP2) AD_CH6 AD_CH6
CN-DISP LED4 55 26
SMW-200-7P WR_RX P54 P65(AIN05/STOP1)
WR_TX
56 25 G/C
CN-PIPE2
5V
A0 P30 P64(AIN04/STOP0) AD_CH4 AD_CH4
57 24

3
L01K
100nH C18K
A1 P31 P63(AIN03) AD_CH3 AD_CH3

1
103
CN-REMO 58
MICOM 23
12V
DC12V Q03K A2 P32 P62(AIN02) R04B 10K AD_CH2 AD_CH2 PIPE_TH2 CN-PIPE1
3 3 KRC102S
59 22

3
Signal R12K A3 P33 P61(AIN01) R05B 10K PIPE_TH1
2 2 WR_RX AD_CH1 AD_CH1
60 21

1
GND 20
1 1 A4 P34 P60(AIN0) R06B 10K ROOM_TH
AD_CH0 AD_CH0
Q01K 61 20

3
C17K
C15K 102 KRA102S A5 P35 AVDD

1
103 C14K
104
62 19 +5V
CN-ROOM
GT-250-3P-TS

12V
5V A6 P36 VAREF
C13K 63 18 C03H C02H C01H SMW-250-03P
R15K R11K
102 C16K A7 P37 P07(INT2) OR1 OR2 OR4 OR5 103 103 103
2.2K
DELET
C12K 4.7K 103 64 17 H/S1
102
C21D

Only for training and service purposes


D12K 104
1N4148 Q04K

10
11
12
13
14
15
16
DAN212K R16K C11K

1
2
3
4
5
6
7
8
9
KRA102S 103
4.7K 12V
Q02K
DELET

XOUT
D02J

XIN

TEST
VSS

VDD

RESET
KRC102S

(SO1)P05
(RxD1)p01

(SCK1)P06
(XTIN)P21

(INT0)P00

(INT1)P03

(SI1)P04
1N4148

(TxD1)P02
BMS ON/OFF SUB_PCB

(XTOUT)P22
Hotel card key pad SUB_PCB

(STOP/INT5)P20
5V Q02K

R01B
1.0M
SW1 10K*6
12V 1 1 12V KRC104S
RY02J 12V
5V 2 2 5V
G5NB-1A

R01T

R05T
R04T
R06T

R03T
D01J
YFW254-03

R02B
3 3

10K
Áß Ó_ TX
1N4148
OSC01B CC_TX 4 4

BR-762C-4P
CN_Contact
R02A 10K 16MHZ 3 Áß Ó_RX Q01K
CC_RX 5 5 KRC104S
5V G/C 2 5V 6 6
RY01J
R03A 200 R01A 1K G5NB-1A

H/S2

CC_SB3

CC_SB2

COMP
1

CC_SB1
1 3 S_B1 State 5V
R16M R06H

CC_RX

CC_TX
KIA7036P CC_SB1 7 7 R03J
C15M 1K 12.1K CC_SB2 S_B2 8 8
Error R04J 10K R01J
4 4
IC01A 2 100 150K/1W
3.6V
C01A C02A
103
103 OR3 CC_SB3 S_B3 9 9
Data_IN
3 3
105 C20D C02J C01J ZNR01J

CS3

CS2

CS1
3 3 104 104 0.01uF 2 2

+5V
CN-CC 400V INR14D561K S1
1 1

CN_POWER
2 2

BR-762C-2P
SMW-200-9P PC01J R02J Power Fuse
L
CN-UPG 1 1 +5V TLP421 150K/1W Y/N
250V/1.0A
1 1
N 2 2
SMW-200-03P
DRY_CONTACT SUB_PCB
6) CST Type
LGE Internal Use Only
1) A2UW146FA0/1/2, A2UW166FA0/1, A2UW186FA0, A3UW186FA0/1, A3UW246FA0, A4UW246FA0,

+5V
5V D01N~D04N CT01N
D06N 1SR139-600
1N4148
CN_TH1

~
1 1 R11H R12H R13H R14H R15H CT_AD
Discharge 2 2
R02N,1.65K,1% +
Suction 3 3 C11H~C15H
18K 6.2K 12.1K 6.2K 6.2K
C02N C01N
4 4 1UF/50V +
R01H~R05H 103 100UF ~
D05N
OUT_Air 1K 1N4148 R01N 5V
1 1 680, 1%
CN_TH2

5V
2 2 R16H R17H R18H R19H R20H
OUT_Pipe 3 3
IC01M C17D
GMS81516 103 6.2K 12.1K 6.2K 6.2K 6.2K
4 4
DISCHARGE +5V C16H~C20H
1 P70(AIN10) VDD 64 R06H~R10H
1UF/50V
1K
CN_TH3

2 2 SUCTION TSUP_E

CN_TH3
Pipe F 1 1 2 P71(AIN11) P67(AIN07) 63 4 4
OUT_AIR TSUP_D 3 3
3 P72(AIN12) P66(AIN06) 62
+ + + + +
OUT_PIPE TSUP_C
4 P73(AIN13) P65(AIN05) 61
1 1
TSUP_F TSUP_B

CN_TH4
5 P74(AIN14) P64(AIN04) 60 2 2
C01H C02H C03H C04H C05H CT_AD TSUP_A 3 3
104 104 104 104 104 6 P75(AIN15) P63(AIN03) 59
4 4
DC_LINK RX_F
R10T~R15T, 270 7 P76(AIN16) P62(AIN02) 58
1
1

D01M 1 1
H/Press INT TX_F + + + + +

CN_TH5
EG01C
Q01M 8 P77(AIN17) P61(AIN01) 57 2 2
2
2

KRC107M W2 RX_E 3 3
9 P00(W) P60(AIN00) 56
4 4
3
3

V2 +5V
10 P01(V) VREF 55 5V
311V
4
4

U2 C06H C07H C08H C09H C10H


GND
11 P02(U) VASS 54 104 104 104 104 104
5
5

W1 TX_E
12 P03(W) P54 53

+
6
6

+5V V1 RX_D C31K


13 P04(V) P53(HPWM0) 52
15uF,450V

1SR139-600
R03T,1K U1 P52(PWM4/PDO4) TX_D
14 P05(U) 51
7
7

R02T
18 1 RY-PWR P51(INT4/TC4)
RX_C R31K
10K U1 15 P06(EMG1) 50
1M,1/2W
8
8

Q01T R01T
107M 10k F0_IPM TX_C
16 P07(CL1/PDW1) P50(INT3/TC3) 49
9
9

C04T

D13K 100D-9
103 IPM_5V_ENB RX_B BUS_COM
CN-IPM
17 P10(INT0) P47(SDA/SO) 48 C13K
R04T LED01T +5V 12V RY-HEATER
P46(SCL/SI) TX_B 471,250V
C01T
1K (RED) 18 P11(INT1) 47
C02T

NTC01K
103 103 RY-4WAY RX_A
19 P12(INT2/TC1)
17 2
U V W U_ V_ W_ Fo 5V +
TEST S/W U1 P45(SCK) 46 BUS_ADDR_LEV
2 3 4 5 6 7 8 9 C03T RY-SV 5V
1 16 3 TX_A
2 3 4 5 6 7 8 9 47uF/50V R05T
U1 20 P13 P44(TxD) 45
1 1 1 1K RY-FAN_1H RY-SV
15 4 LEV_CTL_C
U1
21 P14(PPG) P43(RxD) 44

RC01M
2 2 R08T R07T
10K 1K R06T RY-FAN_1L LEV_CTL_B

2
3 3
22 P15(DVO/TC2)
14 5
56K
U1 P42 43

- 150 -
4 4 RY-FAN_2H
IC01S LEV_CTL_A

1
13 6
IC10S
4 3
3 2
IC06S IC07S
LED02T
U1 23 P16(PDV1) P41 42
IC05S R02A,4.7K R01A,1K
TLP559*6
IC02S IC03S IC04S
+5V (YELLOW) 12 7 RY-FAN_2L LEV_ENABLE Q01Z
R12M~R22M
CN-SV
IC09S IC08S
+5V
U1 24 P17(PDU1) P40 41 KRA107M 4.7K
CN_Test

TLP521*4 1 2
RY-START LEV_B_1

RC02M
IC01A R03A,100 11 8
5 6 8
KIA7036P
C01A
102
U1 25 P20(INT5/STOP) P37 40 RY-4WAY

2
C12S +5V R30M
C07S R01S 104 R06S + 10 9 LEV_B_2
26 TEST P36
2

C04A C03A 39
104 20K C11S 20K IC04M 4.7K
C08S C09S C10S 102 10uF/50V KIA65084 LEV_B_3

1
104 R05S
R02S 104 R03S R04S
104
20K 20K
104
20K
20K
S-TRANS +5V 27 P21 P35 38
D09D C04M CN-4WAY
D08D
+12V 1SR139-400
IC04D LEV_B_4
CN-GATE2 RU2YX 104 28 P22 P34 37 RY-HEATER
9 7805
15
D10D
R08D LEV_A_1
17 29 RESET P33 36

2
6 5 4 3 2 1
6 5 4 3 2 1

V 1.2K
+
C06D LEV_A_2
+
30 XIN P32 35

1
+ +
220UF
C03D LEV_A_3
35V 16
2200UF C04D C15D C16D
C05D 31 XOUT P31 34 CN-HEATER
RY-FAN2_L

G/Y
35V 103 220UF OSC01B R01B,1M
680UF 104 LEV_A_4
D11D R09D 16V 16MHz
C04S C05S C06S 15
V
15 C14D
1K
32 VSS P30 33

3
3
10UF 10UF 10UF 473
+
C07D 8
DC LINK LED01Y(GREEN)
+

+
+

IC03D,SE012N
220UF R03D
R05Y
15K
R03Y R02Y MOTOR
7
7
82K

2
2
+5V 1/4W 70K,3W +5V

Copyright ©2007 LG Electronics. Inc. All right reserved.


35V 14 1 47K H/Press INT
15
D12D 3W C11D,473,630V Q02Y
C3198
1/4W
RY-FAN2_H FAN2

RC03M
13 D05D R07Y,1K Q01Y ZD01Y

7 6 5 4 3 2 1
7 6 5 4 3 2 1
V R01Y

1
1
+
EG01C C12D,100P,1KV C3198 20V 70K,3W R04V R04M~R20M
C08D 2
1W
R04D D06D IC01V R03V 10K R06V 68K
220UF 10,1/4W 1N4937 RY-DISC R01V D01V 33K 1K CN-FAN2
+12V TLP621-BL RY-FAN1_L

G/Y
35V 12 FB01D
R06Y,10K IC01Y C01Y 62K,3W 1SR139-600
3 FBA04HA900 TLP621 R04Y Q01V
+ 222
C02D 2.2K R02V C3198

3
3
47UF IC02D C01V
C01S C02S C03S
50V TLP621-BL 1/4W 1K R05V
10UF 10UF 10UF R11Y,R12Y RY-DISC 1/4W 102
1 IC01D
4 56K,3W 10K MOTOR
+

D13D

2
2
15 R05D
11 FUSE
V
FB02D
5.6K
1/4W D01D~D04D NF01J RC05M
250V/5A RY-FAN1_H FAN1
Vupc Up Vup1 Vvpc Vp Vvp1 Vwpc Wp Vwp1 Un Vn Vn1 Wn Br
+
1SR139-600
Vnc F0 C09D G6551

9 8
9 8

1
1
1 2 3 4 5 6 7 8 9 10 11 12 16 17 14 18 13 15 19 2 R01D
A4UW306FA0, A4UW306FA1

Ufo Vfo Wfo 330UF 27,5W ZNR01D


R06D 5 RC04M
+
ZNR561D14
35V 10 680,1/4W
3 +
CN-FAN1
R07D C13D
1 ,1W 680P D07D
~
CN-GATE1 4 1N4937
50V
GND In Vcc GND In Vcc In
Fo Fo
GND
Fo
Vcc Vcc
In
Fo
GND
Vcc
In
Fo
GND
Vcc
In
Fo
GND
Vcc
In
Fo
GND
RY-START
TEMP C01D R02D R00D C02J C01J RY-PWR
68UF 82K,1W 1M,1/2W 104,275V 104,275V

Only for training and service purposes


Out Si GND Out Si GND Out Si GND Out Si GND Out Si GND Out Si GND Out Si GND 400V
CN-DC CN-PWR
PTC
1 2 4 3 2 1
1 2 CN-AC CN-POWER
4 3 2 1 1 1 2
- +
IPM 1 2
PM50CSD120 1
P U V W N B
HIGH RED
NC
PRESS
DSA-362MA 561 WHITE
2. Outdoor Unit

Comp L2:1.5mH L1:2.0mH


Schematic Diagram

REACTOR
OLP BLACK
28A 0.68mH RM20TPM-2H Power 472
AC440V/DC1600V, 40A 1W/1M
Relay 332 2.0uF GND
1uF 1uF
N
821 500V,25A
COMP 472 1W/1M (102)
400V +
332 2.0uF T
2200uF 100K,2W 1uF 1uF
800V,0.27uF S
821 500V,25A
561
CT01N/30A 1:3000 472 1W/1M (102)
400V MAGNETIC S/W 332 2.0uF
+ R
100K,2W 480V /40A 1uF 1uF 821
2200uF (102)
472 500V,25A
3 ,380V,60Hz
332 CN-INPUT
Schematic Diagram

LGE Internal Use Only


DISCHARGE2 CN-TH4
1 1 +5V
2 2
3 3
R16H R15H R14H R13H R12H R11H R10H R09H
4.7K 12.1K,1% 18K,1% 18K,1% 6.2K,1% 6.2K,1% 12.1K,1% 1.5K,1%
DISCHARGE1 CN-TH3 2012 2012 2012 2012 2012 2012 2012 2012 R08H
1 1 C06M~C11M
R07H 104 CN_LEV1
2 2
R06H
3 3 R09M +15V 1 1
R05H
4 4 10K +5V
SUCTION 2 2
R04H
C03M
R03H IC04M 104 3 3
CN-TH2
PIPE R02H 74HC245AF
1 1 4 4 LEV1
QE VCC IC07M
R01H 1 20
2 2 +5V KIA65084
A0 CS
5 5
3 3 SW1 R01H~R08H C07H C08H C09H C10H C11H C12H INPUT VOLT CS-1
OR1 C07H~C12H 2 19
1K 2012 R04T
4 4 1 + + +
C102*7 6 6
LONG + + + C.T 4.7K A1
3 18
B0 1 18
OUT AIR 2 C06H C05H C04H C03H C02H C01H
R03N C02N
NORMAL 3 20K
10uF 10uF 10uF 10uF 10uF 10uF 102K A2 B1 2 17
2012 2012 JIG POINT R14T C02T 4 17 CN_LEV2
HEAT SINK 50V 50V 50V 50V 50V 50V 1K 102K
1 1 2012 2012 A3 5 16 B2 3 16
1 1
PIPE LENGTH
LOW-V ER_CODE, INDICATOR
A4 B3 4 15
CN-TH1 +15V +5V LED01G : RED_10자리 6 15 2 2
2 2 5V : NORMAL +5V C01L
GND : LONG C05P 103
LED02G : GREEN_1자리 A5 B4 5 14
R01P~R04P
R05P~R10P
102 2012 +5V +5V 7 14 3 3
C09D L03D
470K 2012
104 12uH TX_JIG_S A6 B5 6 13
1/2W 1%
20K 3 R15P~R17P IC01M 8 13 4 4 LEV2
W 2012 R05P 9
4.7K G R01L R02L RX_JIG_S
KID65004AP +15V
A7 B6 7 12
14 Vcc 9 12 5 5
1 8 4.7K 4.7K
100

R06P 1/4W(or 2012) R01G LED01G


V 8
99
98
97
96
95
94
93
92

89
88
87
86
85
84
83
82
90
91

81
2012 2012
1.5K
A2 WP 1 18 GND B7 8 11
2 7 LED0 10 11 6 6
AVcc

P10/AN0

P101/AN1

P103/HEAT_SINK

P105/PIPE

P107/DISCHARGE1

P01/AN01

P03/AN03

P05/AN05

P07/AN07
P97

Vref

AVss

P102/AN2

P104/OUT_AIR

P106/SUCTION

P00/DISCHARGE2

P02/AN02

P04/AN04

P06/AN06
U R07P 5 R18P R02G LED02G
17 1.5K

80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
A1 SCL 2 9 10
2 6
1

R08P 4
R19P 3 P96 LED0 LED1
N RY-PWR CN_LEV3
2

R20P A0 SDA P95 LED1 3 16


C07Z,09Z,11Z : 104K 2012 R09P 4 5
7 1 1
3

R18P~R20P P94 PCB Auto Check RY-C/COMP R10M +15V


SPM2 C08Z,10Z,12Z : 47uF 50V 1 1K 2012 EEPROM 4 15
10K +5V
4

R21P R10P 6 M24C08 P93 IPM Fault Signal 2 2


FairChild 12 +5V RY-OIL/S
R13Z~R15Z : 20 1/4W
5

RX_JIG_PC P92 5 14
7.5K C06P~C08P P14 C04M
FSAM30SM60A D01Z~D03Z : 1N4937 1/2W 1% 102M IC05M 104 3 3
6

IC01P 1 TX_JIG_PC P91 RY-P/ICE


INT3 INT_HP
FSAM20SM60A +15V KIA339A
CN-WRITER
6 13
74HC245AF
2
7

R11P~R13P FAN FG P90 INT4 PSC F/Signal 4 4


C04P R07F C03F RY-HEATER QE VCC IC08M LEV3
D01Z R13Z 15K 3 1K 7 12 1 20
8

104 102 BYTE INT5 Phase Control KIA65084


VB(W) 1/4W 1%
P VB 22
2012
R01A
5 5
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

32 CNVss DC Fan On/off 8 11 A0 CS


+5V 4.7K P20/AN20 2 19 CS-2
VCC(WH) R14P R18T
VCC C01P~C03P
OUT
21
+
2012
4.7K
RXD-6 P87 P21/AN21 RY-PWR
A1 B0 1 18
6 6
331 7.5K R02A R03A RY-C/COMP 10 C01M 104 3 18
COM C07Z C08Z 2012 1/4W 1% IC01A 100 1K TXD-6 P86 P22/AN22 2012
W IN IN(WH) 2012
20 2012 RESET A2 B1 2 17
31 VS 1
KIA7036P
RESET P23/AN23
RY-OIL/S IC02M 4 17
3 R01B
VS(W)
23 C03A 2 +
C02A 0 RY-P/ICE KID65004AP
C01A P24/AN24 A3 B2 3 16
D02Z R14Z 104 3.3UF,50V 102
2012
OSC01B
4MHz
Xout MITSUBISHI RY-HEATER
5 16 CN_LEV4
Vss P25/AN25 RY-HOT GAS
VB(V) 1 16
VB 18
Xin
M16C/62P Group P26/AN26 RY-HOT GAS A4
6 15
B3 4 15
1 1
WCN-W
VCC VCC(VH)
17 + Vcc1
IC02A P27/A7
RY-4WAY 2 15
RY-4WAY
A5 B4 5 14
YL YL OUT 7 14 2 2
1 1 C09Z C10Z R01T
COM(H) P85/NMI Vss RY-FAN(B)_H
COM 16 +5V 3 14 6 13
WCN-V 4.7K A6 B5
VS +5V
P30/A8
RY-FAN(B)_H 8 13 3 3 LEV4
BL BL P84/INT2 RY-FAN(B)_L +5V
V IN(VH) 4 13
2 2 30 IN 15 A7 B6 7 12
P83/INT1 Vcc2 +5V 9 12 4 4
WCN-U VS(V) RY-FAN(B)_L
19 P82/INT0 P31/A9 5 12 GND B7 8 11
PSC (On/off)
RD RD D03Z R15Z R01Z PSC(On/off)
10 11 5 5
3 3 R07Z R08Z R09Z R10Z R11Z R12Z P81/U P32/A10 RY-FAN(A)_H
VB(U) 2K 4.7K 2K 6 11 9 10
VB 13 2K 4.7K 4.7K R02Z RY-FAN(A)_H
P80/U P33/A11
VCC(UH) RY-FAN(A)_L
VCC 12 RY-FAN(A)_L 7 10
+ P34/A12
OUT ENABLE1
COM C11Z C12Z PWM P35/A13 CS-1 8 9 R11M CN_LEV5
U IN IN(UH)
29 VS 11 R03Z ENABLE2 10K +5V
R16Z P75/W P36/A14 CS-2 +15V 1 1
C19Z VS(U) 20A :47,1/4W,1% R04Z ENABLE3 C02M 104
14 P74/W P37/A15 CS-3 C05M
30A :56,1/4W,1% 2012
400VAC R05Z
P73/V
IC06M 104 2 2
P40/A16
1.5uF RSC
10 R17Z R06Z 74HC245AF
OUT(WL) R20Z P72/V 3 3
3.9K,1/4W,1%
P41/A17
QE VCC IC09M LEV5

RXD0/P62
TXD0/P63
CLK1/P65
TXD1/P67
RXD1/P66
R01Z~R06Z

RST1/P64
390, 2012 1 20

EPM/P24
Nw CSC P42/A18 KIA65084

CE/P50
28 C(SC) 9 100
A0 CS
4 4
2012 +5V P43/A19 2 19 CS-3
C13Z 102K,2012

P26 39
P25 40

P23 42
P22 43
P21 44
P51 45

P46 48
P45 49
P47 47

P44
P60
P61 37
CFOD
C(FOD) 8 R02T A1 B0 1 18
5 5

50
35
36

38

46
32
33
34

41
31
C14Z 104,2012 RX-CC 3 18
4.7K
OUT(VL) VFO
VFO 7 A2 B1 2 17

RXD-5
TXD-5
RXD-4
TXD-4
RXD-3
TXD-3

RXD-2
TXD-2
RXD-1
TXD-1
TX-CC 4 17
Nv
27 COM(L)
6 C02Z C03Z C04Z C05Z C06Z A3 B2 3 16
C01Z 5 16 CN_LEV6

RX_Flash
TX_Flash
471 122 471 122 471 122

4.7K

R16T

R15T
R17T

4.7K

4.7K
IN(WL) A4 B3 4 15
Inv._COMP_BLDC IN(WL) 5 6 15 1 1
OUT(UL)
IN(VL) A5 B4 5 14
Nu IN(VL) 4 7 14 2 2
26 +5V
IN(UL) A6 B5 6 13
8 13 3 3

- 151 -
IN(UL) 3 LEV6
A7 B6 7 12
25 NC
COM(L)
COM(L) 2 +5V 9 12 4 4
IC01K
TLP421(Dip) GND B7 8 11
+5V 10 11 5 5
24 NC VCC(L) 1 4
AC_COM
VCC 1
R18Z R06K
9 10
+5V 680 ZD03K
+

4.7k R19Z 2012


20K
2 3
68V
2012
2012 C06K IC02K +5V
C15Z C16Z R01C 102K
IPM Fault Sig. +5V TLP421(Dip) R14K
104Z 47uF 12K,1% 2012 4 1 R12K 30K
25V 50V C17Z C18Z 1.5K 1W D03K~D08K R05T
102 102 R08K 1/4W 1N4007 R06T 4.7K
2012
2012 2012 1K 2012 1% 1K CN_JIG_PC
Phase Freq 3 2
RX
C07K R10K R15K D03K
RX_JIG_PC 1 1
R03C
102K 10K 30K R01M~R08M TX
10K,1% TX_JIG_PC
VDC Q01C 2012
IC03K 1W
68K 2 2
KTC3198Y +5V TLP421(Dip)
C01C
(DIP)
R07K
1 4
AC_COM 3 3
R04C R02C 103K 680 +5V
ZD04K
CN-COIL2 TRANS1
4.7K,1/4 47K,1/4
50V 2012 2 3
68V 4 4
1% 1%
50Hz,DC12V C08K IC04K
R07T
3 102K TLP421(Dip) 1K
BD01C +5V R16K
AC(L) +5V 2012 R13K 2012
4 1
30K RX
~ 5 DF08M
R09K
1.5K
1/4W 1W RX_JIG_S 1 1 CN_JIG_S
BD01S D2 D1 D02C 1%
R07C 1K 2012 TX
C01S C02S C03T
+

C03S C04S 1N4148 TX_JIG_S


RBV2506
680UF 680UF 680UF 680UF
~ D01C 1K,1/4
3 2
R08T
10K
2 2
RBV1506
400WV 400WV 400WV 400WV
1N4007 5% C09K R11K R17K D04K 102K
CN-COIL1 - +
+
INPUT VOLT 102K 10K 30K
2012 2012 3 3
2012
IC05K 1W
R05C
12K,1% +5V TLP421(Dip) +5V
AC (L1) D4 ~ D3
7 ~
C03C +
R06C C02C
1 4
AC_COM 4 4
25V,47uF 102 R38K
REACTOR 2.7K,1% 680 R10T R09T
1 ZD05K
26.8mH/ 9A AC (N) AC(N) 2012 1K 4.7K
2 3
68V
11mH/ 14A RX CN_FLASH
C10K
102K
IC06K RX_FLASH 1 1
+5V TLP421(Dip) R30K
2012 R26K TX
4 1
1.5K
30K +5V TX_FLASH 2 2

Copyright ©2007 LG Electronics. Inc. All right reserved.


R18K 1/4W 1W
1K 2012 1%
3 2
R11T R12T
3 3
+15V C11K R31K D05K
R22K 1K 4.7K
+15V 102K
2012
10K 30K
1W 2012 4 4
IC01S R03S +5V IC07K +5V
TLP251 1.2K +5V TLP421(Dip) RX-CC
1 4
1/4W AC_COM
8 1 R39K RX
C01T CN_CENTRAL
IGBT
GT50J102
C05S
104
AC (L1) CT01N
680
2012
ZD06K
102K
1 1
7
2 Current Trans BD01N R02N D02N 2 3
68V
BD02S 2012 TX
G 4 3 DF08M 1.65K 1%
1N4148 C12K IC08K 2012 TX-CC 2 2
RBV1506 6
~
102K TLP421(Dip)
~ 3 PSC On/Off 1/6W +5V R32K
D2 D1 R01S R02S 2012 4 1 R27K 30K Q01T
C09S 10k 220 5
4
+5V
+
C.T R19K
1.5K
1/4W 1W KRA105
3 3
152J 1/4W 1/4W 1%
1K 2012
6
~ 3 2
4 4
- +
R06S AC (L)
1
R01N
+ C01N
C13K R23K R33K D06K +5V
220uF 102K 10K 30K CN-COM
~ D3 4.7K R07S 1K 1% 2012 1W
D4 D01N IC09K
2012 20K 1/6W 10V(RN)
1N4148 TLP421(Dip)
C09S 2012
+5V
1 4
AC_COM
1 1
R04S 1 4 R40K
0.1uF C06S PSC F/Signal
+120
0.05 R05S
152J
C07S
680
2012 2 3
ZD07K
68V
2 2
71.5k C08S
D01S 2 3 TB2
1N4007 102K 102
C14K
102K
IC10K
TLP421(Dip) R34K
3 3
IC02S 2012 2012 +5V
2012 4 1 R28K 30K
TLP421 R20K
1.5K
1/4W 1W 4 4 C4 C4
1K 2012 1%
5 5
3 2
G G
+5V +5V C15K R35K D07K
R01Y R02Y R24K
R02V~R05V 102K 10K 30K
270K IC01V 2012 1W 6 6 N N
270K D01Y D01V 47K,1/4W,5% IC11K
TLP421_BL
1/2W 1% 1N4007

Only for training and service purposes


1/2W 1% 1N4148 +5V TLP421(Dip)
4 1 1 4
L L
LOW-V AC_COM
R41K
C01Y R03Y R08V 680 ZD08K C3 C3
AC_COM
2012 2 3
68V
103K 4.7K,1% 1K TXD-6
3 2 R01V C16K D01K
50V,2012 INT_HP IC12K
ZD01K,02K
C2 C2
47K,1W,5% 102K +5V TLP421(Dip) R36K 1N4007
R06V 2012 R29K
1K,1/4
4 1
30K 36V,1W
C01V R07V 1.5K 1W R01K~R04K G G
C08D 102K 10K 5% R21K 1/4W
C04D L02D +15V 1K 2012 1% 11K/3W*4 + C02K CN-CP(L)
D01D 103 2012 2012 3 2 D02K R05K
470UF 12uH RXD-6
1N4007 150uF/100V N N
1N4937 50.5K/1W
35V 50V C17K
102K
R25K
10K
R37K
30K
D08K
1 1
2012 PTC 1W L L
+ C05D CN-CP(N)
+ R02D 40 OHM
C1 C1
220uF
2K 35V +15V +5V 1 1
IN 1/2W C01K
R102 GND ZNR01J,02J 102/100V NF01J
1 13
FAN ON/OFF
Q03F R06F NF02J SVC561 J51~J56
20A/250V
R101 4.7K
C101 AC (L) FUSE
1/4W J21~J26 WCN_P(L)
Q01F RY-PWR C05J
FAN FG C07J BR
D101
R01F G4A-1A-PE 332M
+5V C02J
OUT +15V 472M C01J
L01D R04J
NC 3 12 IC04D 1K 2012 C09J 222M 1uF/
12uH 1M
R05F AC (L1) C04J 275VAC
D OUT R03F 1uF/ 275VAC
4.7K 10K 1UF 1/2W C03J
D201
9 7805 2012 2012 C06J
GR/YL
Q02F Q04F C08J 275VAC
FB TNY 332M
+ 222M GND GND

VDC
5 R201
+ + C03D 472M

RY-FAN(A)-H

RY-FAN(B)-H
C06D C07D R02F

RY-FAN(B)-L
RY-FAN(A)-L
NC 268
2) A6UW406FA0

R202 RY-HEATER
220uF PWM 6.8V RY-P/ICE RY-4WAY RY-OIL/S RY-HOT GAS
103 103 C02F

JQ1A-12V

JQ1A-12V

JQ1A-12V

JQ1A-12V
1K 2012 R04F G5NB-1A G5NB-1A G5NB-1A G5NB-1A G5NB-1A AC (N) N N WH
S
PC201
10V 10UF ZD01F
PC201 BP 50V 50V 5.1K
/10V J27~J32 R02J J57~J62 WCN_P(N)
C102 1/4W R03J BK
D202 C01F RY-C/COMP BL L L
6 7 Q01F,02F Q03F,04F 103k 20 20
R01J
GND 630V G4A-1A-E 1/4W,5%
GND KRC104S(Chip) KRA106S(Chip) 1/4W,5%
C01D C02D 20
1000UF 470uF CN-OIL/S 1/4W,5%
TB1
u-POWER MODULE CN-PRESS CN-FAN(A) CN-FAN(B) CN-P/ICE CN-4WAY CN-HEATER CN-HOT GAS
35V 25V
uRM1515-2B C10D SURGE AC-POWER
Vs FG Vcc GND DA-38-302MT-A21 AC220~240V/50,60Hz
102M
CN-MOTOR1 7 6 5 4 3 2 1
2 1 4 3 2 1 3 2 1 2 1 2 1 2 1 2 1 2 1 BK WCN_GND2 BK WCN_GND1
7 6 5 4 3 2 1 2 1 4 3 2 1 3 2 1 2 1 2 1 2 1 2 1 2 1

WH

RD
YL

BL

BK

H/P
L/P
FAN FAN COMP
MOTOR(L) MOTOR(R)
DC FAN (single)
MOTOR
COMP_AC_IM
LGE Internal Use Only
R01M
BUS_ADDR_LEV 10K CN_LEV
5V 12V 1 1
5
IC05M 2 2
C01M KIA65084
IC02K(TLP627) 1 18
BUS_COM
104 3 3
5V DC310V IC01M 2 17
QE VCC
4 4
R01K 1 20 LEV5
1.5K 3 16
TX_D0
5 5
A0 CS_LEV12
2 19 4 15
ERA15-06 245 6 6
IC01K(TLP621) A1 B0
D01K 3 18 C07B
A2 B1 103
CN-DATA 4 17
R19K R25K D07K A3 B2 CN_LEV
R07K,IK 82K/3W ERA15-06 5 16 1 1
RX_D0 1K
1 1 A4 B3
6
C02K 6 15 2 2
R13K IC04K(TLP627)
102 10K
2 2 A5
7 14
B4 5 14
3 3
25V
R02K 3 3 A6
8 13
B5 6 13
4 4
1.5K A7 B6 7 12 LEV6
TX_D1 4 4 9 12 5 5
ERA15-06 GND B7 8 11
IC03K(TLP621) 5 5 10 11 6 6
D02K 9 10 C08B
6 6 103
R20K R26K D08K
R08K,IK 82K/3W ERA15-06
RX_D1 1K
C04K R14K R02M
102 10K
IC06K(TLP627) 10K CN_LEV
25V 5V 12V 1 1
R03K
3
1.5K IC06M 2 2
TX_D2 C002M KIA65084 1 18
ERA15-06
104 3 3
IC02M 2 17
IC05K(TLP621) D03K QE VCC
4 4
1 20 3 16 LEV3
5 5
R27K D09K A0 CS_LEV12
R09K,IK
R21K
ERA15-06
2 19 4 15
6 6

- 152 -
RX_D2 1K 82K/3W 245
A1 B0
3 18 C09B
C06K R15K A2 B1
IC08K(TLP627) 4 17 103
102
25V
10K
A3 B2 CN_LEV
5 16 1 1
R04K
A4 B3
4
1.5K 6 15 2 2
TX_D3
ERA15-06 A5 B4 5 14
7 14 3 3
IC07K(TLP621) A6 B5 6 13
D04K 8 13 4 4
A7 B6 7 12 LEV4
R22K R28K D10K 9 12 5 5
R10K,IK 82K/3W ERA15-06 GND B7 8 11
RX_D3 1K 10 11 6 6
C08K 9 10 C10B
R16K IC10K(TLP627)
102 10K 103
25V

Copyright ©2007 LG Electronics. Inc. All right reserved.


R05K
TX_D4 1.5K R03M
ERA15-06 10K CN_LEV
5V 12V 1 1
IC09K(TLP621)
D05K
1
IC07M 2 2
C003M KIA65084
R29K D11K 1 18
R11K,IK
R23K
ERA15-06
104 3 3
RX_D4 1K 82K/3W
IC03M 2 17
QE VCC
4 4
C10K R17K 1 20 3 16 LEV5
102 IC12K(TLP627)
A0 CS_LEV12
5 5
10K
25V 2 19 4 15
A1
245
B0
6 6
R06K 3 18
1.5K C11B
TX_D5

Only for training and service purposes


A2 B1 103
4 17
ERA15-06
A3 B2 CN_LEV
IC11K(TLP621) 5 16 1 1
D06K
A4 B3
2
6 15 2 2
R24K R30K D12K A5 B4 5 14
RX_D5 R12K,IK
1K 82K/3W ERA15-06 7 14 3 3
A6 B5 6 13
C12K 8 13 4 4
R18K LEV6
102 A7 B6 7 12
10K 9 12 5 5
25V
Schematic Diagram

GND B7 8 11
10 11 6 6
9 10 C12B
103
Schematic Diagram

LGE Internal Use Only


GND R102
IN
13 1
R101
5V

C101
BD01D N/F01N
FUSE_1
+12V D101 NTC D05D DF08M 11mH/1.5A ZNR01N
L1 OUT SCK102 1N4007 (DIP) SVC561D-14A 250V/T3.15A
IC04D 12 3 NC
12uH
OUT D
7805 L
9 D201
+
C01D R02D
C05D + C04D C08D + R01D + R201 TNY
267
FB
5 NC 4.7uF 300K
220uF 103 103 1K
R202
PC201 450V 1/4W
10V 50V 50V 1/2W S BP PC201
N
C102
7
D202
6 C01N
C07D GND 104 CN_PWR
C06D GND
220uF 470UF 275VAC
u-POWER MODULE
25V 25V uPM1512-C2
D05D D05D D05D C09D
1N4007 1N4007 1N4007 102M
5V_EXT
5V
5V R13K
1K/0.62K
C09Y
104
1 6N137 8 4.7K
U05Y
MAX253
D01Y IC03D
R14K
Trans01Y
1 4
SS12 KID78L05BP
I O
2 7 104
CN_OUT
7805
1 8
2 7 2 5 C02Y
104

G
C04Y
22uF/35V 3 6 C01K
3 6
3 6
4 5
D02Y
SS12

C03Y
22uF/35V 4 5
TXD1
U02Y
6N137
C05Y
15pF
1 8
104 TXD1 IC02K(6N137)
C03K
CN-COMM
C07Y
2 7 104
3 6 R02Y
TXD0 R01Y
0.62K
4 5 5.1K
R08Y
U03Y U01Y 1K 1 1
SEL 6N137 C08Y
104
SN65LBC176
1 1 RX
R03Y R07Y 1 8 1 8 2 2
2 7 2 7 ZNR01Y
2 2 TX
RXD0 4.7K 0.33K
3 6 3 6
SVC220D-07B
SEL
3 3
LED1 4 5
R04Y
4 5
R09Y
15pF RXD1 3 3 GND
5.1K 1K
4 4 5V C04K
5
6
4
3
R06Y
0.62K
R12K
5 4 4 4 5V_EXT
R05Y
7 2
4.7K
C06Y
8 1 1K/4.7k 6 3 5 5 12V_EXT
U04Y
RXD1
104
6N137
RXD0 7 2
104
C01X R01X 8 6N137 1
TXD0 1K C02K R15K
102K

- 153 -
2012 2012 1K/0.62K
SEL IC01K(6N137)
3. Central control unit Schematic diagram

5V_EXT
SCK 5V
5V IC05D
5V_EXT 7805
BR1 C10D +
1 o o 2 220uF
3 o o 4
10V
5 o o 6
7 o o 8

GND
RXD1

VCC
TXD1
9 o o 10

SEL
CON5*2 RXD0
44 43 42 41 40 39 38 37 36 35 34 R01G LED01G
470
TXD0 MOSI 1 33 PA4 5V
R02G
470 LED02G
MISO 2 32

5V
PA5
R03G

Copyright ©2007 LG Electronics. Inc. All right reserved.


R02A 4.7K 470 LED03G
5V SCK 3 31 PA6
R03T
1
R03A 120 R01A 1K 1K
3
ATMEGA162
C03A
102 KIA7036P RESET 4 30 PA7
IC01A 2 C01A C02A
R04T
3.6V 4.7uF 104 RXD0 5 29 10K
2012
5V AVCC 6 28 AGND
SWITCH
R02M 1K
TXD0 7 27
V5

OMRON_B3WN
PD2 8 26
OUT IN PD3 9 25
SW4 S10R
8 4
PD4 10 24

V5
7 3 SW3 S20R
SW2 S30R PD5 11 23
6 2
5 1 SW1 S40R
12 13 14 15 16 17 18 19 20 21 22
ON

Only for training and service purposes


RXD2

TXD2
4*K1

Xtal1

Xtal2

GND

VCC
SW DIP-4
W8/1 R05T 10K
CN_JIG
R08S

R07S

R06S

R05S
C05H C04H C03H C02H
4*301
4*K01

V5
W8/1
TXD2 1 1 RX
R06T 10K
2 2 TX
RXD2

R01B
C03X

1M
104,2012 3 3 GND
C02X R03X

12uH
L01D
12uH
L02D
5V C04X 4 4 5V
102K 1K 104
2012 2012

14.7456
OSC01B

5V
Schematic Diagram

Wiring Diagram

1. Room Type Indoor Unit -SQ/SR/ST chassis 2. Art Cool Type Indoor Unit
AC PCB ASM DC PCB ASM

CN-HVB(BL) CN-LR2(WH) CN-LR1(WH) CN-UD(BL) CN-TH1CN-TH2


AC PWB ASM DC PWB ASM

CN-U/D CN-TH1 CN-TH2


THERMISTOR(OUT-PIPE)

CN-GND1
CN-MOTOR1
WH
THERMISTOR(OUT-PIPE)
CN-MOTOR

BK THERMISTOR(IN-PIPE)
FAN
MOTOR YL THERMISTOR(ROOM)
THERMISTOR(IN-PIPE) RD

THERMISTOR(ROOM) STEP
MOTOR

CN-ACDC1

CN-ACDC2
STEP
MOTOR
ZNR

ZNR
Z STEP
MOTOR

CN-POWER
FUSE
250V 3.15A
FUSE RD

GN/YL
H.V. PLASMA
250V 2A ASM BK

BR
AIR CLEAN

BL

RD
CN-D1(WH) CN-D2(WH)
1(L) 2(N) 3 4

CONNECT DISPLAY
SAFETY S/W
CN-POWER

TO OUTDOOR UNIT
PCB ASM PCB
SAFETY S/W
ASM

STEP FORCE S/W


MOTOR
3854A20135Y
3854A20135W

3. Room Type Indoor Unit - S4/S5 chassis 4. Duct Type Indoor Unit - BG/BT chassis
WIRING DIAGRAM

CENTRAL CONTROL IN-PIPE. OUT-PIPE. ROOM.


REMOTE A/CL PTC
TELE CONTROL THERMISTOR CONTROL THERMISTOR THERMISTOR UNIT HEATER
DRY CONTACT

CN-OUT
CN-CC CN-PIPE1 CN-REMO CN-PIPE2 CN-ROOM CN-AIRC CN-PTC VENTILATION
E/HEATER
ZONE CONTROL

CN-ZONE

5
4

TO OUTDOOR UNIT
RD

3
GN/YL
FLOAT S/W

CN-PIPE1

BL

1(L) 2(N)
BR
FUSE
CN-POWER
CN-DISP
CN-MOTOR CN-DPUMP

OPTION
RF-REMOTE
CONTROL
3854A20419A

5. Art Cool Deluxe Type Indoor Unit


A/C MOTOR BLDC MOTOR
CN-MOTOR

MAIN PCB
CN-L/R

STEP
ASM MOTOR
TRIAC
OR
CN-U/D

MOTOR STEP
BK
MOTOR
SH-CAPA

BR
ZNR
YL
CN-HVB

RD RD
H.V.B A/CL
GN/YL BK BK
CN-TH2

THERMISTOR(OUT-PIPE)
CN-TH1

THERMISTOR(IN-PIPE)
CN-POWER

FUSE THERMISTOR(ROOM)
250V 2A
GN/YL

CN-VFD
RD
BR
BL

DISPLAY
1(L) 2(N) 3 4

TO OUTDOOR UNIT
CN-SW/2 CN-SW/3

CN-MAIN LIMIT
FORCED
CN-SW/1

OPERATION CONNECTOR S/W-1


S/W PCB ASM
LIMIT
CN-STEP1 CN-STEP2 S/W-2

SUC SUC
STEP STEP
INDOOR WIRING DIAGRAM MOTOR-1 MOTOR-2
3854A20135X

Copyright ©2007 LG Electronics. Inc. All right reserved. - 154 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

6. Duct Type Indoor Unit - BH/BP chassis 7. CVT Type Indoor Unit - VE chassis

WIRING DIAGRAM

CENTRAL CONTROL IN-PIPE. OUT-PIPE. ROOM. WIRING DIAGRAM STEP


REMOTE A/CL PTC MOTOR
TELE CONTROL THERMISTOR CONTROL THERMISTOR THERMISTOR UNIT HEATER
DRY CONTACT

CENTRAL CONTROL
CN-DOOR

CN-CC
S/W2 CN-UD1

CN-OUT
CN-CC CN-PIPE1 CN-REMO CN-PIPE2 CN-ROOM CN-AIRC CN-PTC VENTILATION S/W1
E/HEATER
DC PCB ASSY AC PCB ASSY
ZONE CONTROL

CN-ZONE

4
A/CL UNIT

TO OUTDOOR UNIT
RD

3
GN/YL GN/YL

CN-ACDC

CN-ACDC
4

TO OUTDOOR UNIT
RD BL

1(L) 2(N)
3
HVB
GN/YL BR
FLOAT S/W

CN-PIPE1

CN-HVB
FUSE
BL

1(L) 2(N)
CN-TH1 CN-TH2 CN-FLOAT CN-DISP CN- CN-
BR MOTOR DPUMP
FUSE
CN-POWER IN-PIPE.
CN-DISP THERMISTOR DISPLAY OPTION
ROOM OUT-PIPE. PCB ASSY
CN-MOTOR CN-DPUMP THERMISTOR THERMISTOR FLOAT S/W

OPTION 3854A20419D
RF-REMOTE
CONTROL
3854A20419B

8. CVT Type Indoor Unit - VB chassis 9. CST Type Indoor Unit - TE/TF/TD chassis
WIRING DIAGRAM

WIRING DIAGRAM STEP CENTRAL CONTROL

A/CL UNIT
MOTOR

HVB
DOOR S/W
OUT-PIPE. ROOM. IN-PIPE. STEP STEP STEP STEP
THERMISTOR THERMISTOR THERMISTOR MOTOR MOTOR MOTOR MOTOR
CN-DOOR

S/W2 CN-UD1 CN-CC


S/W1

CN-PIPE2 CN-ROOM CN-PIPE1 CN-HVB CN-UD1 CN-UD2 CN-LR1 CN-LR2


4

A/CL UNIT
TO OUTDOOR UNIT

RD
3

CENTRAL CONTROL

GN/YL GN/YL
TELE CONTROL
CN-ACDC

CN-ACDC

TO OUTDOOR UNIT
CN-CC

BL
1(L) 2(N)

HVB

3
BR
GN/YL
CN-HVB

FUSE
BL

1(L) 2(N)
CN-TH1 CN-TH2 CN-FLOAT CN-DISP CN- CN-
MOTOR DPUMP
BR
FUSE
IN-PIPE.
THERMISTOR DISPLAY OPTION CN-REMO CN-PTC CN-FLOAT CN-DISP CN-MOTOR CN-DPUMP
ROOM OUT-PIPE. PCB ASSY
THERMISTOR THERMISTOR FLOAT S/W

3854A20419E PTC DISPLAY PCB ASSY OPTION


REMOTE HEATER
CONTROL FLOAT S/W

3854A20419C

10. CST Type Indoor Unit - TE1 chassis 11. CST Type Indoor Unit - TH chassis

Copyright ©2007 LG Electronics. Inc. All right reserved. - 155 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

12. CST Type Indoor Unit - TC chassis 13. CST Type Indoor Unit - TC1 chassis

INDOOR WIRING DIAGRAM


TEMP. PIPE IN
THERMISTOR THERMISTOR FLOAT S/W

CAPACITOR

BR YL CN-ROOM CN-PIPE1 CN-FLOAT


MAIN PCB ASSY
CN-MOTOR

THERMISTOR
BK

CN-PIPE2

PIPE OUT
INDOOR
GN/YL

MOTOR OR

CN-STEP
CN-DPUMP STEP
MOTOR
DRAIN
GN/YL

PUMP
REMOTE
CONTROL

CN-REMO
CN-POWER

FUSE T3.15A

DISPLAY PCB ASSY


CN-DISP

CN-AIRC
BR BL RD
WH
RD
BK

(OPTION)
DOOR S/W

1(L) 2(N) 3 4
CLEANER

RD
BK
AIR
H.V.B

TO OUTDOOR UNIT

P/N:3854A20405A

14. ART COOL MIRROR-SE

Copyright ©2007 LG Electronics. Inc. All right reserved. - 156 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

15. SLIM DUCT - B1,B2

Copyright ©2007 LG Electronics. Inc. All right reserved. - 157 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

5. Outdoor Unit

1. A2UW186FA0 2. A3UW246FA0 3. A4UW306FA0


INVERTER OUTDOOR WIRING DIAGRAM
COMPRESSOR
INVERTER OUTDOOR WIRING DIAGRAM INVERTER OUTDOOR WIRING DIAGRAM
COMPRESSOR COMPRESSOR

RD BL YL REACTOR
RD BL YL REACTOR RD BL YL REACTOR

OR
CN-FAN(A) BL OR OR
RD BL YL BK BK
BK
BR FAN RD BL YL CN-FAN(A) BL RD BL YL BK BK CN-FAN(A) BL
BK BK BK
YL BK FAN(A)
BR FAN BR
U V W CN-COIL1 CN-COIL2 YL YL
CN-LEV2 CN-LEV1

OR
LEV U V W CN-COIL1 CN-COIL2 U V W CN-COIL1 CN-COIL2 BL

CN-LEV2 CN-LEV1
CN-FAN(B) BK

CN-LEV2 CN-LEV2 CN-LEV1


LEV BR FAN(B)
MAIN LEV
YL
PCB
LEV
CN-4WAY 4WV 4WAY VALVE LEV CN-4WAY 4WV 4WAY VALVE
LEV

CN-LEV3
MAIN MAIN

CN-LEV3
LEV
4WAY PCB
CN-4WAY 4WV
VALVE LEV PCB LEV
CN-JIG-PC CN-CENTRAL

CRANKCASE CRANKCASE
CN-HEATER HEATER
CN-HEATER HEATER

CN-JIG-PC CN-CENTRAL

CN-CENTRAL
CN-TH1 CN-TH1
CN-WRITER

CN-TH2 CN-TH3 CN-TH4 CN-TH2 CN-TH3 CN-TH4 OPTION


CN-TH1 OPTION

CN-WRITER
CN-TH2 CN-TH3
DEFROST DEFROST
CN-P/ICE SV (HEATING) CN-P/ICE SV (HEATING)
(H/SINK) (H/SINK)
(AIR/PIPE) (AIR/PIPE) (DISP-I/SUG) (DISP-C)

CN-JIG-PC
(DISP-I/SUG) (DISP-C)
LOW PRESS LOW PRESS
(H/SINK) CN-PRESS SWITCH CN-PRESS SWITCH
(AIR/PIPE) (DISP-I/SUG)
LOW PRESS CN-OIL/S SV OIL SEPERATOR CN-OIL/S SV OIL SEPERATOR
SWITCH
CN-COM CONSTANT CONSTANT

RD
WH
OLP COMPRESSOR RY-C/COMP COMPRESSOR

BK
CN-PRESS CN-COM RY-C/COMP
BR BR BR
C CN-COM C
L N BL R BL
R
CN-GND1 CN-GND2 L N RD S L N BR RD S
GND-1 GND-2 GND-1 GND-2

RD
WH

BL
BK
BR BL
BK BL
BR
BL

WH
BK

BK
BR
BL

BR
BL
BL
BR BL BL BL
BR BR BL
BR BR
1(L) 2(N) 1(L) 2(N) 3(A) 3(B)
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 5(D)

GN/YL

POWER SUPPLY A ROOM B ROOM


A ROOM B ROOM C ROOM A ROOM B ROOM C ROOM D ROOM
POWER SUPPLY POWER SUPPLY
TO INDOOR UNIT
3854A20354A TO INDOOR UNIT 3854A20354B TO INDOOR UNIT 3854A20354C

4. A4UW306FA1 5. A4UW24GFA0, A4UW30GFA0 6. A6UW406FA0


INV-COMP
WIRING DIAGRAM

RD BL YL REACTOR

OR
BL
RD BL YL BK BK BK FAN
BR
CN-FAN(A) (A)
YL

CN-LEV1
OR
U V W CN-COIL1 CN-COIL2 BL
LEV BK FAN
BR
MAIN CN-FAN(B) (B)
YL
PCB
CN-WRITER
CN-CENTRAL

TH1 CN-4WAY 4WV 4WAY VALVE


TH2 TH3 TH4
YL
OPTION
CRANKCASE
CN-JIG-PC

CN-HEATER HEATER
(H/SINK)
(AIR/PIPE) (I/SUC-DISP) (DISP-C)
CN-OIL/S SV OIL SEPERATOR(INV)
CN-COM

WH
WH
BK
CN-PRESS LOW PRESSURE
NOISE FILTER SWITCH
FUSE RELAY CONS-COMP
250V,20A
R
L N BL RD S C
GND-2 GND-1
BR
BL
BR

BL

BR BL
GN/YL
BL GN/YL BR
BR BR T/B
BR

1(L) 2(N) 1(L) 2(N) 3(A) 3(B)

Power Supply

LEV LEV LEV LEV LEV LEV


A B C D E F

CN-LEV-A CN-LEV-B CN-LEV-C CN-LEV-A CN-LEV-B CN-LEV-C


LED1 LED2 LED3 LED1 LED2 LED3

BRANCH DISTRIBUTOR-(A) BRANCH DISTRIBUTOR-(B)


CN-ROOM-A CN-ROOM-B CN-ROOM-C L N S CN-ROOM-A CN-ROOM-B CN-ROOM-C L N S
L N S L N S L N S CN-PWR L N S L N S L N S CN-PWR

A B C D E F
TO INDOOR UNIT TO INDOOR UNIT 3854A20354G

Copyright ©2007 LG Electronics. Inc. All right reserved. - 158 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

7. A2UW146FA0, A2UW146FA1 8. A3UW186FA0, A3UW186FA1


INVERTER OUTDOOR WIRING DIAGRAM
COMPRESSOR
INVERTER OUTDOOR WIRING DIAGRAM
COMPRESSOR

RD BL YL REACTOR
RD BL YL REACTOR

OR

RD BL YL BK BK CN-FAN(A) BL OR
BK
BR FAN RD BL YL BK BK CN_FAN(A) BL
YL BK
BR FAN
U V W CN-COIL1 CN-COIL2 YL
CN-LEV2 CN-LEV1

LEV U V W CN_COIL1 CN_COIL2

CN_LEV2 CN_LEV1
MAIN LEV
4WAY
PCB CN-4WAY 4WV
VALVE
LEV
CN_4WAY 4WV 4WAY VALVE
LEV
MAIN

CN_LEV3
LEV PCB
CN-JIG-PC CN-CENTRAL

CN-PRESS

CN_JIG_PC CN_CENTRAL
CN_TH1
CN_TH2 CN_TH3
CN-WRITER

CN-TH1

CN_WRITER
CN-TH2 CN-TH3
LOW PRESSURE
(H/SINK) CN_PRESS SWITCH
(AIR/PIPE) (DISP_I/SUG)

(H/SINK)
(AIR/PIPE) (DISP-I/SUG)

CN-COM

RD
WH
BK
CN_COM
L N
CN-GND1 CN-GND2 L N
GND_1 GND_2

BK
BR
BL

WH
BK

BK

BR
BL
BL
BR BL BL
BR BR
1(L) 2(N) 1(L) 2(N) 3(A) 3(B)
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C)

GN/YL

POWER SUPPLY A ROOM B ROOM


A ROOM B ROOM C ROOM
POWER SUPPLY
TO INDOOR UNIT
3854A2035
3854A203 TO INDOOR UNIT

9. A4UW246FA0 10. A7UW486FA0, A8UW586FA0 11. A2UW146FA2, A2UW166FA0/1


INV-COMP(A)

INVERTER OUTDOOR WIRING DIAGRAM WIRING DIAGRAM


COMPRESSOR
RD BL YL REACTOR

RD BL YL REACTOR OR

CN-FAN(A) BL
RD BL YL BK BK BK FAN
BR
(A)
YL
OR
CONS-COMP(C)
CN-LEV1

4WAY
RD BL YL BK BK CN-FAN(A) BL U V W CN-COIL1 CN-COIL2 CN-4WAY 4WV VALVE
BK LEV BR
C
BR FAN BL R S
YL
MAIN
PCB
CN-WRITER

CN-C/COMP2 RD
CN-CENTRAL

U V W CN-COIL1 CN-COIL2
CN-LEV2 CN-LEV1

PTCR
LEV TH1
TH2 TH3 TH4 OPTION
CN-HEATER CRANKCASE BR BL
HEATER
CN-JIG-PC

CN-4WAY 4WV 4WAY VALVE


LEV OPTION
MAIN (H/SINK)
CRANKCASE
CN-LEV3

(AIR/PIPE) (SUC/DISP_I) (DISP-C) CN-HEATER2


HEATER_2
LEV PCB
CN-C/FAN FM COOLING FAN
CN-COM

CRANKCASE
CN-HEATER HEATER
CN-JIG-PC CN-CENTRAL

OIL
CN-TH1 NOISE FILTER CN-OIL/S SV SEPERATOR
CN-TH2 CN-TH3 CN-TH4 OPTION
FUSE
CN-WRITER

DEFROST 250V,20A LOW PRESSURE


SV (HEATING) CN-PRESS
CN-P/ICE SWITCH
(H/SINK) L N RY-C/COMP CONS-COMP(B)
(AIR/PIPE) (DISP-I/SUG) (DISP-C) GND-2 GND-1
LOW PRESS WH
CN-PRESS SWITCH BK BK BR BL
C
R S
BR

BL

RD
SV OIL SEPERATOR
GN/YL
CN-OIL/S BL GN/YL T/B BL
BR BR
CONSTANT BL T/B
RD
WH

OLP COMPRESSOR
BK

CN-COM RY-C/COMP
BR
C 1(L) 2(N) 1(L) 2(N) 3(A) 3(B)
BL R
L N RD S
GND-1 GND-2
Power Supply
BR
BL LEV LEV LEV LEV LEV LEV LEV LEV
A B C D E F G H
BR
BL

BL BL CN-LEV-A CN-LEV-B CN-LEV-C CN-LEV-D CN-LEV-A CN-LEV-B CN-LEV-C CN-LEV-C


BR BR LED-1 LED-2 LED-3 LED-4 LED-1 LED-2 LED-3 LED-4

BRANCH DISTRIBUTOR-(A) BRANCH DISTRIBUTOR-(B)


1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 5(D)
CN-ROOM-A CN-ROOM-B CN-ROOM-C CN-ROOM-D L N S CN-ROOM-A CN-ROOM-B CN-ROOM-C CN-ROOM-D L N S
L N S L N S L N S L N S CN-PWR L N S L N S L N S L N S CN-PWR

Only 8Rooms Model

A B C D E F G H
A ROOM B ROOM C ROOM D ROOM
POWER SUPPLY TO INDOOR UNIT TO INDOOR UNIT
TO INDOOR UNIT 3854A2 3854A20354K

Copyright ©2007 LG Electronics. Inc. All right reserved. - 159 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

Components Locations
1. Indoor Unit
MAIN P.C.B ASM
1) Split Type
• DC part

• AC part

Copyright ©2007 LG Electronics. Inc. All right reserved. - 160 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

2) Art Cool Type

TOP VIEW BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 161 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

3) Art Cool Deluxe Type


• A/C MOTOR

TOP VIEW

C03J JP32

CN_MOTOR
C04J CN_TH2
CN_L/R(BL)

JP33
JP1 CN
_U
/D
(W

JP34
7
R01J H)
4
CN_CC
FUSE 250V/T2A
SMPS
CN
_S
UC
(W
H)
JP28
CN_POWER

1 3
JP43 CN
_H

D07D
EARTH VB
(B
C05J L1 C06D L)
JP29
C06J CN
_T
H1
ZNR01J

JP58
JP40
JP39

JP44
C01J
NF02J C04D CN

JP45
_V
JP35 FD
(W
R05K H)
SD01D
D02K

JP11
C09D IC04D
C01E
NF01J JP30 NTC JP46
D01K

PCB : 6870A90120C

JP48
ZNR02J

ASM : 6871A10111
JP47
C01D

CN_CON(BL)
BZ01E

JP42
JP41
R03J

TR01J
R02J

D05D

JP49
JP31

IC01D OSC01B
Q01V
~ ~
C02A IC01A
D02D

JP56
JP12
IC1

JP55
C05D
+ -
ZD02D

JP19
IC01K IC02K

JP51
JP38

JP52

JP54
BD01D

JP53
IC02D JP50
IC01J
Q01C
IC03D

BOTTOM VIEW

JP20
R04H
C03H
R03H

JP32
CN-L/R(BL)
CN-MOTOR

C03J

CN-CH2
JP33

H) C04J
(W
/D
-U
CN
JP27

JP1
CN-CC
JP5

R01J
JP34

R24G

R23G

R22G

R21G

IC01M IC04M
H)
(W
UC
-S FUSE
L) CN
(B
VB
JP57

250V/T2A
-H
JP28

CN
IC02M
CN-POWER

EARTH
C01F

JP43
D07D

C06J
H1 SMPS C05J
C N-T
L1
JP4

C06D JP29
R02F
R01F

C10D

ZNR01J
H)
JP58

D(W
JP44

F
-V
JP39

CN JP35
JP40

C01J
JP45

C07D

NF02J
C04V

C04D
R04V
JP3

MICOM SD01D
D02K

C03V C01E
JP30
50
R02H
R01H
R05H
R03V

45

C08D
JP16

ZNR02J
IC04D

C01D
55

NTC
JP48

40

Q02E
R03E

JP46 C09D

JP47
C02H
Q03E

Q01E
C01L R01E
R02E
R02L
JP25

NF01J
R06H
C01H

R03K
R21H
R23H
R22H
CN-CON(BL)

D01K

TR01J
JP9
JP2
1

R03J
30
JP49

R02J
R04E
JP24

JP26

D05D
C02D
R01B

JP31

IC01D
25

R01L
10
OR1H
OR3H

JP8
R02G

R05V
R06V
20

JP18

JP15

R05K
15

R01A C01A
JP41

JP10

OR2H
R05D

IC02K
JP42

IC01K
BC01D
Q01V

JP17

R04J

C05D
Q01K
C01G
R01G

IC01J
D02D
C01X

JP19

Q02V

JP37
R08D

IC02D
L02X
JP12

JP56

L01X

IC01A R01P IC03D


R06D

JP14 R02A
JP55

R03D
R02D

JP50
R02K
R04K
ZD02D
Q01C
R07D

IC1
JP38

JP36
JP21

JP22
JP54

JP53

JP23
JP51
JP52

R04D JP13 JP7 JP6 C01K R01K

Copyright ©2007 LG Electronics. Inc. All right reserved. - 162 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

3) Art Cool Deluxe Type


• BLDC MOTOR

TOP VIEW

BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 163 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

4) Duct Type
• High static (BH/BG chassis)
• Built in type (BP chassis)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 164 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

• Low static (BT, BT1 chassis)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 165 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

• Low static (B1, B2)

TOP VIEW

BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 166 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

5) Casset Type
• 1 way(TC Chasis)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 167 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

• 1 way(TC1 Chasis)

TOP VIEW

BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 168 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

• 4 way(TE/TF/TD chassis)

58

• 4 way(TE1/TH chassis)
TOP VIEW

BOTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 169 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

6) Convertible type
• VE chassis
AC part
TOP VIEW BOTTOM VIEW

DC part
TOP VIEW BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 170 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

• VB chassis

Copyright ©2007 LG Electronics. Inc. All right reserved. - 171 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

• VB chassis
TOP VIEW

BOTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 172 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

2. Display ASSEMBLY
1) Split Type

2) Convertible Type
VE chassis
TOP VIEW

PWB ASM:6871A20390 PCB:6870A90065K

BOTTOM VIEW

VB chassis

3) Art Cool Type

TOP VIEW

BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 173 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

4) Art Cool Deluxe Type


TOP VIEW
SEJIN ELECTRON INC. SVM-GP1119AI P/N 3210018043 REV1 R7
R8 R17 R9 Q2

R5
D1 C18 1
C13 TP1

C20
C8 R10 Q1

C9 R13
M43 TP2
C19
TP3
TP4
R3 R4
C7 R18
C21
M44 M42 TP5
M45 R19
R2 R6 TP6

C15 C14

BOTTOM VIEW

TP1
TP2

TP3
TP4

TP7
TP8

5) Art Cool Mirror


TOP VIEW

BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 174 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

3. Outdoor Unit
1) Component side

Copyright ©2007 LG Electronics. Inc. All right reserved. - 175 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

2) Solder side

Copyright ©2007 LG Electronics. Inc. All right reserved. - 176 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

3) Central control PCB)


1) Top View

2) Bottom View

Copyright ©2007 LG Electronics. Inc. All right reserved. - 177 -


LGE Internal Use Only
Only for training and service purposes
Schematic Diagram

4. SUB P.W.B ASSEMBLY


1) Art Cool Type

TOP VIEW

BOTTOM VIEW

Copyright ©2007 LG Electronics. Inc. All right reserved. - 178 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Troubleshooting Guide
Refrigeration Cycle Diagram

1. A2UW146FA0/1/2, A2UW166FA0/1, A2UW186FA0, A3UW186FA0/1

Exchanger
OUTDOOR UNIT

Th4

Heat

Th3
Reversing

Compressor
Valve

Th1

Drier
Th2

Th3
Low Pressure

Accumulator
S/W

LEV-C

LEV-B

LEV-A
Header
3 rooms model

3 rooms model
Room C

Room B

Room C

Room B
Room A

Room A

Heating
Cooling
Field Piping

Refrigerant Flow
Field Piping
Liquid
Gas

Copyright ©2007 LG Electronics. Inc. All right reserved. - 179 -


LGE Internal Use Only
Only for training and service purposes
4 room model OUTDOOR UNIT
Room D
Reversing
Room C Valve
Field Piping
Gas Room B
Troubleshooting Guide

Room A
Header

Only for training and service purposes


Check
Check
Valve(2) Valve(1)
2. A3UW246FA0, A4UW246FA0

Copyright ©2007 LG Electronics. Inc. All right reserved.


Oil Th5
Seperator

Th2 Th1

Accumulator Heat

- 180 -
Exchanger

Constant
Compressor
Inverter
4 room model Compressor
LEV-D
Valve(1)
Solenoid

Room D Th3
LEV-C
Field Piping Room C Low Pressure
Liquid LEV-B S/W
Room B Th4
LEV-A
Room A

Refrigerant Flow Drier


Valve(2)
Solenoid

Cooling
Heating

LGE Internal Use Only


OUTDOOR UNIT

Reversing
Valve
Room D

Room C
3. A4UW306FA0

Field Piping
Gas Room B

Room A

Only for training and service purposes


Th5
Header

Check Check
Valve(2) Valve(1)

Copyright ©2007 LG Electronics. Inc. All right reserved.


Oil
Seperator

Th2 Th1
Heat
Exchanger

- 181 -
Accumulator

Constant
Compressor
Inverter
Compressor
LEV-D
Room D
Th3
Valve(1)
Solenoid

LEV-C
Room C
Field Piping LEV-B
Room B Low Pressure
Liquid S/W
LEV-A
Room A
Th4

Refrigerant Flow Drier

Cooling
Valve(2)
Solenoid

Heating

LGE Internal Use Only


Troubleshooting Guide
OUTDOOR UNIT
Refrigerant Flow Reversing
Valve
Cooling
Heating
4. A4UW306FA1
Troubleshooting Guide

Th5

Only for training and service purposes


Check
Check Check
Check
Valve(2
Valve(2) Valve(1
Valve(1)
) )

Copyright ©2007 LG Electronics. Inc. All right reserved.


Oil Oil
Seperator
Accumulator Seperator

Th2 Th1
Heat
Exchanger

- 182 -
Constant
Solenoid Valve(1)

Compressor Inverter
Compressor

Low Pressure
LowPressure Th3
S/W
S/W
Field Piping
Gas(Ø 15.88)

Th4
Field Piping
Liquid (Ø 6.35)
Drier
Receiver

LGE Internal Use Only


OUTDOOR UNIT
Refrigerant Flow Reversing
Valve
Cooling
Heating
5. A6UW406FA0

Th5

Only for training and service purposes


Check
Check Check
Check
Valve(2
Valve(2) Valve(1
Valve(1)
) )
Oil

Copyright ©2007 LG Electronics. Inc. All right reserved.


Oil
Seperator
Accumulator Seperator

Th2 Th1

Heat

- 183 -
Exchanger

Constant
Solenoid Valve(1)

Compressor Inverter
Compressor

Low Pressure
LowPressure Th3
S/W
S/W
Field Piping
Gas(Ø 19.05) L.E.V.

Th4
Field Piping
Liquid (Ø 9.52)
Drier
Receiver

LGE Internal Use Only


Troubleshooting Guide
OUTDOOR UNIT
Refrigerant Flow
Reversing
Cooling Valve
Heating
Troubleshooting Guide

Only for training and service purposes


Th6

Check Check Check


6. A7UW486FA0, A8UW566FA0

Copyright ©2007 LG Electronics. Inc. All right reserved.


Valve(3) Valve(2) Valve(1)
Oil
Accumulator Seperator
Heat
Exchanger
Th3 Th2 Th1

- 184 -
Constant
Solenoid Valve(1)

Compressor 2 Constant Inverter


Compressor 1 Compressor

Th5
Low Pressure Th4 L.E.V.
Field Piping
S/W
Gas(Ø 19.05)

Field Piping
Liquid (Ø 9.52)
Drier
Receiver

LGE Internal Use Only


Troubleshooting Guide

7. BD Unit

Refrigerant Flow

Heating
Cooling

Piping ( Ø 9.52) Piping ( Ø 15.88)


Main Gas

Outdoor Unit
Main Liquid
D Liquid(Ø9.52)

C Liquid(Ø9.52 or Ø12.7) LEV-A

B Liquid(Ø9.52 or Ø12.7)
LEV-B

A Liquid(Ø9.52 or Ø12.7)
LEV-C
LEV-D

D Liquid(Ø6.35)

C Liquid(Ø6.35)

B Liquid(Ø6.35)

A Liquid(Ø6.35)

[Indoor Unit]

Copyright ©2007 LG Electronics. Inc. All right reserved. - 185 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Self-diagnosis Function
■ Error Indicator
• The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
• Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
• If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
• After error occurrence, if error is released, error LED is also released simultaneously.
• To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
• Having or not of error code is different from Model.
Indoor Error
LED 1 LED 2 Indoor
Error code Description INV TPS
(Red) (Green) Status
00 No Error ON
01 Indoor Room themistor error 1time OFF
02 Indoor in-piping sensor error 2times OFF
03 Remote controller error 3times OFF
04 Drain Pump error 4times OFF
05 Communcation error between in and out 5times OFF
06 Indoor Out-Piping sensor error 6times OFF
07 Differnt mode operation 7times OFF

Outdoor Error
LED 1 LED 2 Indoor
Error Code Description INV TPS
(Red) (Green) Status
21 DC Peak (IPM Fault) 2times 1time OFF
22 CT 2(Max CT) 2times 2times OFF
23 DC Link Low Volt. 2times 3times OFF
24 L_P/Heater Sink 2times 4times OFF
25 Low voltage / Over voltage 2times 5times OFF
26 DC Comp Position Error 2times 6times OFF
27 PSC Fault Error 2times 7times OFF
28 DC Link High Volt 2times 8times OFF
32 D-Pipe High (INV) 3times 2times OFF
33 D-Pipe High (Normal) 3times 3times OFF
40 CT Sensor (Open/Short) 4times O OFF
41 INV. D-PipeTh Error(Open/Short) 4times 1time OFF
44 Outdoor air Th Error(Open/Short) 4times 4times OFF
45 Cond. Pipe Th Error(Open/Short) 4times 5times OFF
46 Suction Pipe Error(Open/Short) 4times 6times OFF
47 Const D-pipe Th Error(Open/Short) 4times 7times OFF
51 Capacity over 5times 1time OFF
52 Signal error(INV Board ↔ Main Board) 5times 2times OFF
53 Signal error (Indoor ↔ Outdoor) 5times 3times OFF
60 EEPROM Check Sum Error 6times O OFF
61 Cond. Pipe High 6times 1time OFF
62 Heatsink High 6times 2times OFF
63 Cond. Pipe Low 6times 3times OFF
65 Heatsoml Th error (Open/Short) 6times 5times OFF
❈ CH52 : Only A2UW146FA0(FM17AH UL0)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 186 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Cycle Troubleshooting Guide

Trouble analysis
1. Check temperature difference between intake and discharge air, and operating current.

Temp. difference : approx. 0°C All amount of refrigerant leaked out.


Current : less than 80% of Check refrigeration cycle.
rated current

Temp. Difference
Temp. difference : approx. 8°C Refrigerant leakage
Current : less than 80% of Clog of refrigeration cycle
rated current Defective compressor

Operating Current
Temp. difference : less than 8°C
Excessive amount of refrigerant
Current : near the rated
current

Temp. difference : over 8°C Normal

Notice:
Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relatively higher, temperature difference is smaller. When the room air humidity is relatively lower
temperature difference is larger.

2. Check temperature and pressure of refrigeration cycle.

Suction pressure Temperature


(Compared with (Compared with Cause of Trouble Description
the normal value) the normal value)

High Defective compressor Current is low.

Higher
Normal Excessive amount of High pressure does not quickly
refrigerant rise at the beginning of operation.

Insufficient amount of Current is low.


Lower Higher refrigerant(Leakage)
Clogging

Notice:
1. The suction pressure is usually 4.5~6.0 kg/cm G at normal condition.
2

2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with
putty.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 187 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Electronic Parts Troubleshooting Guide

1. A2UW146FA0/1/2, A2UW166FA0/1, A2UW186FA0, A3UW186FA0/1

❇ Refer to electronic contorol device drawing & schematic diagram.

Trouble 1 The Product doesn’t operate at all.

Turn off the main power and wait until LED on outdoor PCB is off.

Turn on the main power again.

Does "Beeping" sound is made from the indoor unit?

NO YES

Check the voltage of power(AC220V/AC240V, 50Hz). • Primarily, the operating condi-


tion of Micom is O.K.
• The voltage of main power.
• The voltage applied to the unit.
• The connecting method of Indoor/Outdoor connecting cable (each color)
• The P.W.B. Ass'y
(Fuse, Noise Filter, Power Transformer, IC01D, IC02D, etc.) • Check CN-DISP1

The operation check of the P.C.B. Ass'y

Procedure Specification Remedy


1) The input voltage of power trans- 1) AC230V ± 30V 1) Replace
former. : Check the rated voltage power transfomer.
2) The output voltage of power 2) 14V ± 3V 2) Replace
transformer. power transfomer.
3) IC01D(7812) 3) DC12V 3) Replace IC01D.
4) IC02D(7805) 4) DC5V 4) Replace IC02D.
5) IC01A(KIA7036) 5) The voltage of micom pin 29 5) Replace IC01A.
: DC4.5V↑

Copyright ©2007 LG Electronics. Inc. All right reserved. - 188 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Trouble 2 Product doesn't operate with the remote controller.

Turn on main power.

While the compressor has been stopped, the compressor does not operate
owing to the delaying function for 3 minutes after stopped.

When the compressor stopped Indoor Fan is driven by a low speed.


At this point the wind speed is not controlled by the remote controller.
(When operated in the Sleeping Mode, the wind speed is set to the low speed as force.)

Caused by the remote controller. Caused by other parts except


the remote controller

When the mark ( ) is displayed in LCD Check the contact of CN-DISP 1 connector
screen, replace battery.

When the detect switch (double key) inside the Check DISP PWB Ass'y
remote controller door is fault, it is impossible to -Voltage between CN1 ➀ - ➆ : DC +5V
operate temperature regulating(▲ / ▼) and wind
speed selecting.

Check the Display PWB Ass'y • Check receiver ass'y

Copyright ©2007 LG Electronics. Inc. All right reserved. - 189 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Trouble 3 The Compressor/Outdoor Fan are don't operate

Turn on the main power.

Operate Cooling Mode by setting the disired temperature of the remote controller is less
than one of the Indoor temperature by 1°C at least.

When in air circulation mode, compressor/outdoor fan is stopped.

Check the sensor for Indoor temperature is attatched as close as to be effected by the
themperature of Heat Exchange (EVA.)

When the sensor circuit for Indoor temperature and connector are in bad connection or are
not engaged, Compressor/Outdoor fan is stopped.
• Check the related circuit of R02H(12.1K), R01H(1K), R04H(6.2K), R03H(1K), C01H(102),
C02H(102), Micom(pin No. , ).
• Check the Indoor temperature sensor is disconnected or not (about 10K at 25°C).

Check the Relay(RY-PWR, RY-START) for driving Compressor.


• Check the voltage between brown and blue cable of terminal to connect the Outdoor
(About AC220V / 240V).
• Check the related circuit of relay in Outdoor PCB Ass'y.

Check Point Comp. ON Comp. OFF

Between Micom(No. 19) and DC 5V DC 0V


GND
Between IC01M(No. 10) and DC 1V↓ DC 12V
GND

Turn off main power.

Check the electrical wiring diagram of Outdoor side.


Check the open or short of connecting wires between Indoor and Outdoor.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 190 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Trouble 4 When indoor Fan does not operate.

Turn off main power.

Check the connection of CN-FAN.

Check the Fan Motor.

Check the Fuse(AC250V, T2A).

Check the related circuit of indoor Fan Motor.

• The pin No. 38 of micom and the part for driving SSR.(Q01M)
• Check the related pattern.
• Check the SSR.
- SSR Open: Indoor Fan Motor never operate.
- SSR short: Indoor Fan Motor always operates in case of ON or OFF.

Turn on the main power

Check the SSR high speed operation by remote control.


(the Indoor Fan Motor is connected)

The voltage of Pin No 1(orange) and 3(black) of CN-FAN.

About AC 160V over About AC 50V over

SSR is not damaged Check SSR

Copyright ©2007 LG Electronics. Inc. All right reserved. - 191 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

Trouble 5 When the louver does not operate.

• Confirm that the vertical louver is normally geared with the shaft of Stepping Motor.
• If the regular torque is detected when rotating the vertical louver with hands ⇒ Normal

• Check the connecting condition of CN-U/D or CN0L/R Connector


• Check the soldering condition(on PCB) of CN-U/D or CN0L/R Connector

Check the operating circuit of the vertical louver

• Confirm that there is DC +12V between pin ➀ of CN-U/D, CN0L/R and GND.
• Confirm that there is a soldering short at following terminals.
- Between 1 , 2 , 3 and 4 of MICOM - Between 17 , 18 , 19 and 20 of MICOM
- Between 4 , 5 , 6 and 7 of IC01M - Between 5 , 6 , 7 and 8 of IC01M

If there are no problems after above checks.

• Confirm the assembly condition that are catching and interfering parts in the link of the
vertical louver

Copyright ©2007 LG Electronics. Inc. All right reserved. - 192 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

General Information
■ Error Indicator (Indoor)
• The function is to self-diagnosis air conditioner and express the troubles if there is any trouble.
• Error mark is displayed on display window of indoor units and wired-remote controller, and LED of outdoor unit
control board.
• If more than two troubles occur simultaneously, lower number of error code is first displayed.
• After error occurs, if error is released, error LED is also released simultaneously.

1 digit 10 digit

■ Indoor Error

Error Indoor
Contents Case of error
code Status
01 Air sensor (open/short) Open / Short Off
02 Inlet pipe sensor Open / Short Off
03 Communication(Indoor ↔ Wired R/Control) Communication Poorly Off
04 Drain pump/ Float switch Float switch Open Off
05 Communication(Indoor ↔ Outdoor) Communication Poorly Off
06 Outlet pipe sensor Open / Short Off
07 Different operation mode Different operation mode Off

Copyright ©2007 LG Electronics. Inc. All right reserved. - 193 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

■ Error Indicator (Outdoor)


Outdoor Error
Ex) Error 21 (DC Peack)

2 Times 2 Times 2 Times

LED01G
(RED)
1 Sec. 1 Sec. 1 Sec.
1 Time 1 Time 1 Time

LED02G
(GREEN)
2 Sec. 2 Sec.

Error LED01G LED02G Outdoor


Contents (Green) Case of error Status
code (Red)
21 IPM Fault (Compressor Over current) 2 times 1 time Compressor malfunction,IPM Fault Off

22 CT 2(Max. Current) 2 times 2 times Current is 14A Off

23 DC Link Low Volt. 2 times 3 times DC Link volt. Is 140V Off

24 Low / High press 2 times 4 times Low / High press switch OPEN Off

25 AC Low / AC High Volt. 2 times 5 times Abnormal AC volt. Input. Off

26 DC Compressor Position 2 times 6 times Off

27 PSC Fault 2 times 7 times Off

28 DC Link High Volt 2 times 8 times Off Off

32 Discharge Pipe Temp. High (INV) 3 times 2 times Off Off

33 Discharge Pipe Temp. High (Cons.) 3 times 3 times Off Off

Copyright ©2007 LG Electronics. Inc. All right reserved. - 194 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

■ Error Indicator (Outdoor)


Outdoor Error

Error LED01G LED02G Outdoor


Contents (Green) Case of error Status
code (Red)
40 CT Circuit 4 times CT Circuit malfunction Off

41 D-pipe sensor INV. (open/ short) 4 times 1 time Open / Short Off

44 Air sensor (open/ short) 4 times 4 times Open / Short Off

45 Cond. Pipe sensor (open/ short) 4 times 5 times Open / Short Off

46 Suction pipe sensor (open/ short) 4 times 6 times Open / Short Off

47 D-pipe sensor Cons. (open/ short) 4 times 7 times Open / Short Off

51 Over capacity 5 times 1 times Over combination Off

53 Communication (Indoor Outdoor) 5 times 3 times Communication Poorly Off

60 EEPROM check sum 6 times Check sum mismatching Off

61 Cond. Pipe sensor temp. high 6 times 1 time Cond. Temp. high Off

62 Heat sink sensor temp. high 6 times 2 times Heat sink temp. high Off

65 Heat sink sensor (open/ short) 6 times 5 times Open / Short Off

Copyright ©2007 LG Electronics. Inc. All right reserved. - 195 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

1) Troubleshooting CH01, CH02, CH06

Display
Title Cause of error Check point & Normal condition
code
• Open / Short
Indoor air sensor • Soldered poorly Normal resistor : 10KΩ/ at 25°C (Unplugged)
01
• Internal circuit error Normal voltage : 2.5Vdc / at 25°C (plugged)

• Open / Short
Normal resistor : 5KΩ/ at 25°C (Unplugged)
02 Indoor inlet pipe sensor • Soldered poorly
Normal voltage : 2.5Vdc / at 25°C (plugged)
• Internal circuit error

• Open / Short
Normal resistor : 5KΩ/ at 25°C (Unplugged)
06 Indoor outlet pipe sensor • Soldered poorly
Normal voltage : 2.5Vdc / at 25°C (plugged)
• Internal circuit error

10kΩ 2.5Vdc

Ω V

Check the resistance Check the voltage

Check Point
1. Unplug the sensor on Indoor unit PCB.
2. Estimate the resistance of each sensor.
3. If the resistance of the sensor is 10KΩ/ 5KΩ at 25°C, then sensor is normal.
4. If the resistance of the sensor is 0 KΩ or ∞, then sensor is abnormal. → Change the sensor.
5. Plug the sensor on Indoor unit PCB and Power ON.
6. Estimate the voltage of each sensor.
7. If the voltage of the sensor is 2.5Vdc at 25°C, then sensor is normal.
8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. → Repair or Change the PCB.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 196 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

2) Troubleshooting CH03

Display
Title Cause of error Check point & Normal condition
code
• Connection of wire
Communication • Open / Short • Main PCB Volt. DC12V
03
Wired R/C • Wrong connection • Noise interference

Wired R/C Indoor Unit


CN-REMO
12V S GND 12V S GND

12Vdc 12Vdc

V V

Check the Volt. Check the Volt.

Check Point
1. Check the wire connection. (Open / Short) → Repair the connection
2. Check the soldering state of connector. (Soldered poorly) → Repair or Change the PCB.
3. Check the volt. Of main PCB power source. (DC 12V, DC 5V) → Repair or Change the main PCB.
4. Check the installation of wired remote controller. (Noise interference) → Adjust the state of installation

Copyright ©2007 LG Electronics. Inc. All right reserved. - 197 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

3) Troubleshooting CH04

Display
Title Cause of error Check point & Normal condition
code
• The connection of wire(Drain pump/ Float switch)
Drain pump • Float switch Open. • Drain pump power input. (220V)
04
/ Float switch (Normal : short) • Drain tube installation.
• Indoor unit installation. (Inclination)

CN Float

CN-D/PUMP
CN-Float
0Ω

Check the resistance

Check Point
1. Check the wire connection. (Open, Soldered poorly) → Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short) → Check the float switch.
3. Check the level of water
4. Check the volt. Of Drain pump power supply. (AC 230V) → Repair or Change the main PCB.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 198 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

4) Troubleshooting CH05, CH53

Display
Title Cause of error Check point & Normal condition
code
• Power input AC 220V. (Outdoor, Indoor)
• The connector for transmission is disconnected.
04
• The connecting wires are misconnected.
/ Communication
• Communication poorly • The GND1,2 is not connected at main GND.
53 (Indoor → Outdoor)
• The communication line is shorted at GND.
• Transmission circuit of outdoor PCB is abnormal.
• Transmission circuit of indoor PCB is abnormal.

Check Point
1. Check the input power AC230V. (Outdoor, Indoor unit)
2. Check the communication wires are correctly connected.
→ Adjust the connection of wire
→ Confirm the wire of “Live”, “Neutral”
3. Check the resistance between communication line and
GND. (Normal : Over 2MΩ)
4. Check the connector for communication is correctly
connected.
5. Check the connection of GND1, GND2, and main GND.
6. If one indoor unit is operated normally, outdoor PCB is no
problem.
→ Check the another indoor unit.
* CH05 is displayed at indoor unit, CH53 is displayed at out-
door unit.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 199 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

5) Troubleshooting CH21

Display
Title Cause of error Check point & Normal condition
code
• An instant over current in the U,V,W phase
- Comp lock
• Instant over current - The abnormal connection of U,V,W
21 DC Peak • Over Rated current • Over load condition
• Poor insulation of IPM - Overcharging of refrigerant
- Pipe length.
• Poor insulation of compressor

Comp
U Resistance(Ω) at 20°C
Inverter Constant
Ω Terminal
comp. comp.
V W U-V 0.64 0.8
V-W 0.64 0.8
W-U 0.64 0.8

Copper
Comp pipe Resistance(Ω) at 20°C
Inverter Constant
Terminal
Ω comp. comp.
U-GND 2MΩ 2MΩ
V-GND 2MΩ 2MΩ
W-GND 2MΩ 2MΩ

Check Point
1. Check the wire connection. (U,V,W)
2. Check the load condition. (Refrigerant, Pipe length, …) → Adjust the load condition
3. Check the electricity leakage of the compressor. → Normal : Over 2MΩ.
4. Check the resistance of compressor. → Normal : 0.65Ω(INV), 0.8Ω(Cons.) → No difference at each terminal.
5. Check the insulation from water at IPM part. → Check the trace of water.
6. Check the IPM circuit.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 200 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

6) Troubleshooting CH22

Display
Title Cause of error Check point & Normal condition
code
Malfunction of compressor
21 Max. C/T Blocking of pipe
Over current (14A ) Low voltage input
Refrigerant, pipe length, blocked, …

Malfunction of current detection circuit.


C/T (Open / Short)
22 Initial current error
Internal circuit The voltage of “C01N” Is 4.0Vdc(25A) .

Check Point - +
1. Check the power source. + -
2. Check the fan operation is right.
+ -
3. Check the current.
4. Check the install condition.
5. Check the internal circuit. (C/T, Diode, Resistor)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 201 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

7) Troubleshooting CH23, CH28

Display
Title Cause of error Check point & Normal condition
code

DC Link • DC link volt. is • Check the power source.


23
Low voltage. 140Vdc . • Check the components.

DC Link • DC link volt. is • Check the power source.


28 High voltage 420Vdc . • Check the components.

Check Point
1. Check the power source.
2. Check the components
(B/Diode, Reactor, PSC Parts )

Copyright ©2007 LG Electronics. Inc. All right reserved. - 202 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

8) Troubleshooting CH24, CH25

Display
Title Cause of error Check point & Normal condition
code

24 • Low / High press • Check the connection of “CN_Press”.


Press S/W Open
S/W open. • Check the components.

• Abnormal Input voltage • Check the power source.


25 Input voltage
(140Vac , 300Vac . • Check the components.

TRANS1
50Hz, DC12V
CN PRESS

CN TRNAS1

Check Point
• CH 24 • CH 25
1. Check the connection of “CN_PRESS” 1. Check the power source.
2. Check the install condition for over load. 2. Check the components
3. Check the SVC V/V open. (Trans1, B/Diode, Diode, Resistance)

4. Check the leakage of refrigerant.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 203 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

9) Troubleshooting CH26, CH27

Display
Title Cause of error Check point & Normal condition
code

• Check the connection of comp wire “U,V,W”


DC Compressor • Compressor
26 • Malfunction of compressor
Position position detect error • Check the component of “IPM”, detection parts.

• Check the component of “IGBT” .


27 PSC Fault • Over current at “IGBT”
• Check the components.

B
E

Check Point
• CH 26 • CH 27
1. Check the connection of “U,V,W” 1. Check the component of “IGBT”
2. Check the insulation of IPM part. 2. Check the components
3. Check the compressor. (same with CH21) (IGBT, R04S, NF1, BD02S)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 204 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

10) Troubleshooting CH32, CH33

Display
Title Cause of error Check point & Normal condition
code

D-pipe (Inverter) • Check the discharge pipe sensor for INV.


32 temp. high • Discharge sensor • Check the install condition for over load.
(105°C ) (Inverter) temp. high • Check the leakage of refrigerant.
• Check the SVC V/V open.

• Check the discharge pipe sensor for Cons.


D-pipe (Constant)
• Discharge sensor • Check the install condition for over load.
33 temp. high
(Cons.) temp. high • Check the leakage of refrigerant.
(105°C )
• Check the SVC V/V open.

D-Pipe temp.

Toff(105) °C

T2(95) °C
T1(90) °C

COMP Frequency
Normal Normal OFF
(Hz)
LEV Openness Normal Normal OFF Control
(Pulse)

Check Point
• CH 32 • CH 33
1. Check the install condition for over load. 1. Check the install condition for over load.
2. Check the SVC V/V open. 2. Check the SVC V/V open.
3. Check the leakage of refrigerant. 3. Check the leakage of refrigerant.
4. Check the constant compressor. (same with CH21)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 205 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

11) Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65

Display
Title Cause of error Check point & Normal condition
code
• Open / Short
41 • Normal resistor : 200KΩ / at 25°C (Unplugged)
D-pipe sensor (Inverter) • Soldered poorly
• Normal voltage : 4.5Vdc / at 25°C (plugged)
• Internal circuit error

• Open / Short
44 • Soldered poorly • Normal resistor : 10KΩ / at 25°C (Unplugged)
Air sensor
• Internal circuit error • Normal voltage : 2.5Vdc / at 25°C (plugged)

• Open / Short
45 Condenser Pipe sensor • Soldered poorly • Normal resistor : 5KΩ / at 25°C (Unplugged)
• Internal circuit error • Normal voltage : 2.5Vdc / at 25°C (plugged)

• Open / Short
Suction Pipe sensor • Soldered poorly • Normal resistor : 5KΩ / at 25°C (Unplugged)
46
• Internal circuit error • Normal voltage : 2.5Vdc / at 25°C (plugged)

• Open / Short
D-pipe sensor (Constant) • Soldered poorly • Normal resistor : 200KΩ / at 25°C (Unplugged)
47
• Internal circuit error • Normal voltage : 4.5Vdc / at 25°C (plugged)

• Open / Short
Heat sink sensor • Soldered poorly • Normal resistor : 10KΩ / at 25°C (Unplugged)
65
• Internal circuit error • Normal voltage : 2.5Vdc / at 25°C (plugged)

Check Point
1. Estimate the resistance of each sensor.(Unplugged)
2. Estimate the voltage of each sensor.(Plugged)
3. If the resistance of the sensor is 0 kΩ or ∞, then sensor is abnormal.
Ω If the voltage of the sensor is 0 V or 5Vdc, then sensor is abnormal.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 206 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

12) Troubleshooting CH51, CH60

Display
Title Cause of error Check point & Normal condition
code

51 • Over capacity • Check the indoor unit capacity.


Over capacity
Combination • Check the combination table.

EEPROM • Check the PCB ASM P/No.


60 • Check sum error
Check sum • Check the poor soldering.

Model Gross max. capacity Max. single indoor unit capacity


A2UW146FA0
A2UW146FA1 21k 12k
A2UW146FA2
A2UW166FA0
A2UW166FA1 24k 12K
A2UW186FA0
A3UW186FA0 30k 18k
A3UW246FA0 33k 24K
A4UW246FA0
39k 24K
A4UW306FA0
A6UW406FA0 52k 24K

Check Point
• CH 51 • CH 60
1. Check the indoor unit capacity. 1. Check the insertion condition of EEPROM.
2. Check the poor soldering

Copyright ©2007 LG Electronics. Inc. All right reserved. - 207 -


LGE Internal Use Only
Only for training and service purposes
Troubleshooting Guide

13) Troubleshooting CH61, CH62

Display
Title Cause of error Check point & Normal condition
code

Condenser • Condenser pipe sensor


61 • Check the load condition.
pipe sensor detected high • Check the sensor of Condenser pipe sensor.
temp. high temp.(65°C)

• Heat sink sensor


Heat sink sensor • Check the fan is locked.
62 detected high
temp. high • Check the sensor of heat sink.
temp.(85°C)

Heat Sink temp.

Toff °C

T2 °C
T1 °C

COMP Frequency
Normal Normal OFF Normal
(Hz)

Check Point
• CH 61 • CH 62
1. Check the install condition for over load. 1. Check the fan is locked.
(Refrigerant, Pipe length, Blocked, …) 2. Check the Outdoor temp. is very high.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 208 -


LGE Internal Use Only
Only for training and service purposes
(3-way) Valve

(3-way) Valve
3-way Valve (Liguid Side) 3-way Valve (Gas Side)

Valve cap
Valve cap
Open position
Open position Closed position
Closed position
Pin
Pin

To piping
To piping connection Service Service
connection Service Service port cap port
port cap port
To outdoor unit
To outdoor unit

Works Shaft position Service port Shaft position Service port

Shipping Closed Closed Closed Closed


(with valve cap) (with cap) (with valve cap) (with cap)

Air purging Open Open Closed Open


1. (Installation) (counter-clockwise) (push-pin or with (clockwise) (push-pin or with
vacuum pump) vacuum pump)

Operation Open Closed Open Closed


(with valve cap) (with cap) (with valve cap) (with cap)

Pumping down Closed Closed Open Open


2.
(Transfering) (clockwise) (with cap) (counter-clockwise) (connected
manifold gauge)

Evacuation Open Open Open Open


3. (Servicing) (connected (connected
manifold gauge) manifold gauge)

Gas charging Open Closed Open Open


4. (Servicing) (with cap) (with charging
cylinder)

Pressure check Open Open Open Open


5. (Servicing) (connected (connected
manifold gauge) manifold gauge)

Gas releasing Open Open Open Open


6. (Servicing) (connected (connected
manifold gauge) manifold gauge)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 209 -


LGE Internal Use Only
Only for training and service purposes
(3-way) Valve

(1) Pumping down

Indoor unit Liquid side

Close Outdoor unit


2-Way
valve

Gas side

Open
3-Way
valve

Indoor unit Liquid side

Close
2-Way
valve

Gas side

Open
3-Way
valve

manifold gauge

Low-
handle
(CLOSE) Hi- handle
(CLOSE)

• Procedure
1. Confirm that both the gas side and liquid side 6. Operate the air conditioner at the cooling cycle
valves are set to the open position. and stop it when the gauge indicates 1kg/cm g.2

- Remove the valve stem caps and confirm that the 7. Immediately set the gas side valve to the closed
valve stems are in the raised position. position.
- Be sure to use a hexagonal wrench to operate - Do this quickly so that the gauge ends up indicat-
the valve stems. ing 1kg/ g.
2. Operate the unit for 10 to 15 minutes. 8. Disconnect the charge set, and mount the liquid
side and gas side valve caps and the service port
3. Stop operation and wait for 3 minutes, then con-
nut.
nect the manifold gauge to the service port of the
- Use torque wrench to tighten the service port nut
gas side valve.
to a torque of 1.8kg.m.(4.2kg.m/5.5kg.m)
- Connect the hose of the gauge with the push pin
to the service port. - Be sure to check for gas leakage.
4. Air purging of the charge hose.
- Open the Low-handle valve on the gauge
slightly to air purge from the hose.
5. Set the liquid side valve to the closed position.
• Be sure to short pressure S/W. otherwise Low pressure S/W detect low pressure skete and stops the compressor.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 210 -


LGE Internal Use Only
Only for training and service purposes
(3-way) Valve

(2) Evacuation
(All amount of refrigerant leaked)

Indoor unit Liquid side

Open Outdoor unit


2-Way
valve

Gas side

Open
3-Way
valve

Indoor unit Liquid side

Open
2-Way
valve

Gas side

Open
3-Way
valve

manifold gauge

Vacuum pump
Low-
handle
(OPEN) Hi- handle
(OPEN)

• Procedure
1. Confirm that both the liguid side valve and gas 6. Disconnect the charge hose from the vacuum
side valve are set to the opened position. pump.
- Vacuum pump oil.
2. Connect the vaccum pump to the center hose of
If the vacuum pump oil becomes dirty or deplet-
the manifold gauge.
ed,replenish as needed.
3. Connect the service port of the gas side valve to
7. Mount the valve caps and the service port caps.
the low side of the gauge.
4. Evacuation for approximately one hour.
- Confirm that the gauge needle has moved
toward-76 cmHg (vacuum of 4 mmHg or less).
5. Close the Low handle of the gauge turn off the
vacuum pump, and confirm that the gauge needle
does not move(approximately 5 minutes after
turning off the vacuum pump).

Copyright ©2007 LG Electronics. Inc. All right reserved. - 211 -


LGE Internal Use Only
Only for training and service purposes
(3-way) Valve

(3) Gas Charging


(After Evacuation)

Indoor unit Liquid side

Open Outdoor unit


2-Way
valve

Gas side

Open
3-Way
valve

Indoor unit Liquid side

Open
2-Way
valve

Gas side

Open
3-Way
valve

Charging manifold gauge


cylinder

Low-handle
Check valve (OPEN) Hi- handle
(OPEN)

• Procedure
1. Connect the gauge to the charging cylinder. 4. Immediately disconnect the charge hose from
- Connect the charge hose which you disconnect- the gas side valve's service port.
ed from the vacuum pump to the valve at the
This is different from previous procedures.
bottom of the cylinder.
Because you are charging with liquid refrigerant
- If you are using a gas cylinder, also use a scale
from the gas side, absolutely do not attempt to
and reverse the cylinder so that the system can
charge with larger amounts of liquid refrigerant
be charged with liquid.
while operating the air conditioner.
2. Purge the air from the charge hose.
- Open the valve at the bottom of the cylinder and - Stopping partway will allow the gas to be dis-
press the check valve on the charge set to purge charged.
the air. (Be careful of the liquid refrigerant). The - If the system has been charged with liquid
procedure is the same if using a gas cylinder. refrigerant while operating the air conditioner
3. Open the low handle on the gauge and charge turn off the air conditioner before disconnecting
the system with liquid refrigerant. the hose.
- If the system can not be charged with the speci- 5. Mount the valve stem nuts and the service port
fied amount of refrigerant, it can be charged nut.
with a little at a time (approximately 150g each - Use torque wrench to tighten the service port
time) while operating the air conditioner in the nut to a torque of 1.8 kg.m.(4.2kg.m/5.5kg.m.)
cooling cycle; however, one time is not suffi- - Be sure to check for gas leakage.
cient, wait approximately 1 minute and then
repeat the procedure(pumping down-pin).

Copyright ©2007 LG Electronics. Inc. All right reserved. - 212 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Exploded View
Indoor Unit
SQ/SR chassis
135316

152313
135314

152302

131410 733010

359011

342800
159830

354210

352115
147581 352116

268711A
35211B 346810
263230B 135516

352150 263230A
135311

146811

266090 268711B
267110 268711C

249951 W0CZZ

Copyright ©2007 LG Electronics. Inc. All right reserved. - 213 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

ST chassis

135316
267110

152313
135314

152302

131410 733010

359011

342800

159830
135311 W51620

147581A
352115
147581B 352116

268711A
35211B 346810
263230B 135516

352150 263230A
268711B
146811

249951
266090 268711C

W0CZZ

Copyright ©2007 LG Electronics. Inc. All right reserved. - 214 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

S4 chassis

135312

152313
152302

131410 733010
159830

342800

359011

135311
354210

147581

346810

35211B
268711A 135516

263230B

352150 266090

146811
263230A

267110 249951 268711B

Copyright ©2007 LG Electronics. Inc. All right reserved. - 215 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

S5 chassis

135312

152313
152302

152302

131410 733010

342800

159830 359011

135311

354210

147581

346810

35211B
268711A 135516

263230B

352150 266090

146811
263230A

267110 249951 268711B

Copyright ©2007 LG Electronics. Inc. All right reserved. - 216 -


LGE Internal Use Only
Only for training and service purposes
135515

249951
354210
130400

266090
268711C

352115
267110 268711B

Only for training and service purposes


SP1 chassis(Art cool type)

330870
352116

268711D 35211B
146811A 352150

Copyright ©2007 LG Electronics. Inc. All right reserved.


135316
135500C 263230B 263230A
152302
146811B 352380 131410
147581

- 217 -
135311B

135500B
147581

135311A
346810

159830 349600

135313
146811B

135311C 147581 146811B


268711A 359012
135500A

LGE Internal Use Only


Exploded View
Exploded View

Art Cool Deluxe Type(SU, SZ chassis - A/C Motor)

146811 135316

152302
668713A
146811

668713B

135080A
135313
263020

135080B
263230B 263230A

733010

267110 359011

159830

342800

354210
131410

346810

352150
352114 249951
352118
W0CZZ
35211B 266090

146811A

147581
135311
268714 249941

Copyright ©2007 LG Electronics. Inc. All right reserved. - 218 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Art Cool Deluxe Type(SU, SZ chassis - BLDC)

146811B 135316

152302
268711B
146811B

145200A

145200B
268711C

135080A
135313
263020

135080B
263230B 263230A

159830
733010

267110 359011

342800

354210

131410

346810

352150
352114 249951
352118

266090
35211B

146811A

147581
135311
268711A 249941

Copyright ©2007 LG Electronics. Inc. All right reserved. - 219 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Art Cool Deluxe Type(S3 chassis - A/C Motor)

146811B 135316

152302
268711B
146811B

145200A

145200B
268711C

135313
263040

263230B 263230A

733010

267110 359011

159830 342800

354210
131410

346810

352150
352115 249951
352116

266090
35211B

146811A

147581
135311
268711A 249941

Copyright ©2007 LG Electronics. Inc. All right reserved. - 220 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Art Cool Deluxe Type(S3 chassis - BLDC)

146811B 135316

152302
268711B
146811B

145200A

145200B
268711C

135313
263040

263230B 263230A

733010

267110 359011

159830 342800

354210
131410

346810

352150
352115 249951
352116

266090
35211B

146811A

147581
135311
268711A 249941

Copyright ©2007 LG Electronics. Inc. All right reserved. - 221 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Art Cool Mirror Type(SE chassis - BLDC)

135316

152302
263230C

268711C

268711A

268711D

146811B

733010

159830
359011
342800
267110

354210
131410

352150
346810

135516 266090

35211B

135500 263230A
147581
146811A
249951 263230B
268711B

135311

Copyright ©2007 LG Electronics. Inc. All right reserved. - 222 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

DUCT LOW(B1)

263230A

263230C

159830

336600B

346810B 249951

268711A
263230B
346810A

359012A

268711B

336600A
354210
352118A

359012B
330870
352118B

267110
158591
352150

Copyright ©2007 LG Electronics. Inc. All right reserved. - 223 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

DUCT LOW(B2)

263230A

159830 263230C

336600B

346810
359012A

249951

268711A
263230B

336600A

359012B
268711B

354210
352118A
267110

330870
352118B

158591
352150

Copyright ©2007 LG Electronics. Inc. All right reserved. - 224 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Duct Type - High Static

359012B
137214

346810

359012A

336600A
336600B

W0CZZ

249951
354210

152302 268711

352111
263230A
263230B
263230C
552111 267110

352118

330870

Copyright ©2007 LG Electronics. Inc. All right reserved. - 225 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Duct Type - Low Static (BT, BT1 chassis)

152302

346810

336610

267111
359012B

A/CL

W0CZZ

359012A

267110
354210

249951
263230A
268714

552111
263230B
352111
352118

330860

263230C

Copyright ©2007 LG Electronics. Inc. All right reserved. - 226 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Built in Duct type (BP chassis)

137214

249951

267110

263230A

263230B
336600A
359012B
263230C
268711

158591
W0CZZ

352118A 359012A

346810
336600B

352118B
354210

330870

237202

*Accessory: Front Panel Assembly.

Copyright ©2007 LG Electronics. Inc. All right reserved. - 227 -


LGE Internal Use Only
Only for training and service purposes
267110B 267110A 352150
346810 352390 158591
130911

135500

Only for training and service purposes


266010
Option
359011
330870 352115
352116
Cassette Type - 1 way (TC1 chassis)

Copyright ©2007 LG Electronics. Inc. All right reserved.


- 228 -
354210

266090

249951
268711

159830

* Accessory: Front Panel Assembly.


263230A 263230B 263230C

LGE Internal Use Only


Exploded View
267110B 267110A 354212
346810 W1SZ 158591
130911
Exploded View

266012

Only for training and service purposes


359011
137211 330860 352115
352116
Cassette Type - 1 way (TC chassis)

Copyright ©2007 LG Electronics. Inc. All right reserved.


268712

354210

- 229 -
135802

146811
152302

140570 266090
W0CZZ

249951
152312 268714

159830
135312
738290 738282

OW INS
NE TA
RS LL
MA MA
NU NU
AL AL

263230A 263230B 263230C

LGE Internal Use Only


Exploded View

Cassette Type - 4 way[TE chassis]

266090

249951

263230C 263230B 263230A

268711

159830

354211

352118 35211A

158591
266010

330870
352111
Applied for 18K Model

Copyright ©2007 LG Electronics. Inc. All right reserved. - 230 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

130412

W0CZZ

346811

359012

140570

130911A

* Accessory : Front Panel Assembly

267110B

130911B 267110A

352150
(Optional)

Copyright ©2007 LG Electronics. Inc. All right reserved. - 231 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Cassette Type - 4 way[TE(1) chassis]

266090

249951

263230C 263230B 263230A

268711

159830

354211

352118 35211A

158591
266010

330870
352111
Applied for 18K Model

Copyright ©2007 LG Electronics. Inc. All right reserved. - 232 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

130412

359012

140570

130911A

* Accessory : Front Panel Assembly

130911B 267110A

352150

Copyright ©2007 LG Electronics. Inc. All right reserved. - 233 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Cassette Type - 4 way(TF chassis)

266090

249951

354211B
268711

354211A

159830 263230C

352118B
263230A
552111
263230B
352118A

158591
266010

352111

330870

Copyright ©2007 LG Electronics. Inc. All right reserved. - 234 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

130412

W0CZZ

346810

359012

W4056

130911B

* Accessory: Front Panel Assembly

267110B 267110A
352150
130911A

Copyright ©2007 LG Electronics. Inc. All right reserved. - 235 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Cassette Type - 4 way(TH chassis)

266090

159830
268711

263230C
249951

130412

158591

354211

266010

552111

330870 263230A
352118
263230B

Copyright ©2007 LG Electronics. Inc. All right reserved. - 236 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

130412

346810

359012

140570
130911B

130912A

* Accessory : Front Panel Assembly


130912B

352150 267110

130911A

Copyright ©2007 LG Electronics. Inc. All right reserved. - 237 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Cassette Type - 4 way(TD chassis)

249951
266090

268714
159830

263230A
263230B
130411 263230C

354211

352118A

552111

330870 352118B

158591
266012

Copyright ©2007 LG Electronics. Inc. All right reserved. - 238 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

130411

W0CZZ

146811 268712

346810

152312

359012

140570
130911B
130912A

135313

135802
267110A 137211
130912B

130911A

267110B 352150B

Copyright ©2007 LG Electronics. Inc. All right reserved. - 239 -


LGE Internal Use Only
Only for training and service purposes
Exploded View

Convertible Type (VE chassis)

137211 135310

268711C 147581

152302

135313
146811

733010

267110

W0CZZ
330870
266000

352115

352116
135500

346810
263230A 131410

354210
35211B
268711A
352150
268711B
W4810 263230B
266000
359011
Applied for 249951
342800
Plasma Model
Applied for
Plasma Model 330780

159830 266090

Copyright ©2007 LG Electronics. Inc. All right reserved. - 240 -


LGE Internal Use Only
Only for training and service purposes
135310

146811
Exploded View

147590A

Only for training and service purposes


346810
147590B 266000 130911
Convertible Type (VB chassis)

352150 235450

Copyright ©2007 LG Electronics. Inc. All right reserved.


237900 268711C W0CZZ
268711A

249951
352115
267110

- 241 -
137211 354210
35211A

135314
263230A

263230B

359011
330870

135303 152302

342800

LGE Internal Use Only


437212

554031
558511

552113
552112
435511
Outdoor Unit

546810

Only for training and service purposes


A2UW146FA2, A2UW166FA1

559010

Copyright ©2007 LG Electronics. Inc. All right reserved.


W0CZZ

261704

- 242 -
268711
649950

552116 263230A

661400A 263230B
661400B
554160 561410

447910 552200

W49810 552203A
552203B
437211
552203A
435301 552203B
430411

LGE Internal Use Only


Exploded View
437212

554031
Exploded View

A2UW166FA0

552113
552112
435511

546810

Only for training and service purposes


559010

Copyright ©2007 LG Electronics. Inc. All right reserved.


W0CZZ

261704

- 243 -
268711
649950

552116 263230A

661400A 263230B
661400B
554160 561410

447910 552200

W49810 552203A
552203B
437211
552203A
435301 552203B
430411

LGE Internal Use Only


554031 437212
A2UW146FA0

552113
435512 552112

Only for training and service purposes


559010 546810
W0CZZ

Copyright ©2007 LG Electronics. Inc. All right reserved.


566000
435511
268711
447910
261704

- 244 -
649950

435301 263230A

552116 263230B

661400A 561410

661400B
552200
554160

W49810 552203A
552203B
552203A
552203B
437211 430411

LGE Internal Use Only


Exploded View
554031 437212
Exploded View

A3UW186FA1

552113
435512 552112

Only for training and service purposes


559010 546810
W0CZZ
566000
435511

Copyright ©2007 LG Electronics. Inc. All right reserved.


268711
447910
261704

649950

- 245 -
435301 552116
263230A
548490
661400A 263230B
661400B 561410
661400C
554160
552200

W49810 552203A

552203B
437211 430411

LGE Internal Use Only


554031 137213A 435300 137213B

552113
435512 552112

Only for training and service purposes


558511
A2UW146FA1, A2UW186FA0

559010 546810
W0CZZ

Copyright ©2007 LG Electronics. Inc. All right reserved.


566000

268711
447910
261704 435511

- 246 -
649950

435301
263230A
552116
263230B
661400A
561410
661400B
554160 552200

W49810 552203A
552203B
552203A
437211
552203B

430411

LGE Internal Use Only


Exploded View
554031
437212
Exploded View

A3UW186FA0

552113
435512 552112

558511

Only for training and service purposes


559010 546810
W0CZZ
566000

Copyright ©2007 LG Electronics. Inc. All right reserved.


268711
447910
261704
435511
649950

- 247 -
435301
263230A
552116
661400A 263230B
661400B
561410
661400C
554160 552200

W49810 552203A

437211
552203B

430411

LGE Internal Use Only


554031 137213A 435300 137213B
552201
552111 552204
A3UW246FA0

552116 552115
552113

435512 558511
566000

Only for training and service purposes


559010 546810 261704
649950
263230A 548490

Copyright ©2007 LG Electronics. Inc. All right reserved.


263230B
561410A
268711
263230C
561410B
447910 435511

561410C

- 248 -
661400A
W0CZZB W0CZZA 661400B
435301
661400C

554160A 552200

554160B 552203A

552203B
W49810
437210

430411

LGE Internal Use Only


Exploded View
554031 137213A 435300 137213B
552201
552111 552204
Exploded View

A4UW246FA0

552116 552115
552113

435512 558511
566000

Only for training and service purposes


349600

559010 546810 261704


649950
263230A 548490

Copyright ©2007 LG Electronics. Inc. All right reserved.


263230B 561410A
268711
263230C 561410B
447910 435511
561410C

- 249 -
661400A
W0CZZB W0CZZA 661400B
435301
661400C
661400D

552200 552203A
554160A
552203B
554160B

W49810
437210

430411

LGE Internal Use Only


137213A
554031
552115 435300
548490
552116 552111
137213B

Only for training and service purposes


435511
435512
A4UW24GFA0, A4UW30GFA0

668711

Copyright ©2007 LG Electronics. Inc. All right reserved.


649950
546810
263230A

263230B

- 250 -
561411A
561411
561411B
561411C
561411D

561410
435301 554160 552113A
559010 552113B

437210

430410
552113

LGE Internal Use Only


Exploded View
554031 137213A 435300 137213B

566000 552201 552111


Exploded View

561410A
A4UW306FA0

552116 552204
552115
561410B
352113
561410C
435512

Only for training and service purposes


558511
548490
552113

546810A
263230A

263230B 559010

Copyright ©2007 LG Electronics. Inc. All right reserved.


263230C 649950

546810B
268711
661400A

- 251 -
661400B
W0CZZA 661400C
435511
435301 W0CZZB 661400D

W49810
552203A
552203B
447910
552200

554160B

554160A

437210 261704
430411

LGE Internal Use Only


554031 137213A 435300 137213B

566000 552201 552111

561410A 552116 552204


A4UW306FA1

552115
561410B
352113
561410C
435512
558511

Only for training and service purposes


548490
552113
546810A
263230A

263230B 559010

Copyright ©2007 LG Electronics. Inc. All right reserved.


263230C 649950

546810B
268711

- 252 -
W0CZZA
435511
435301 W0CZZB

W49810
552203A
552203B
447910

554160B

554160A

437210 261704
430411

LGE Internal Use Only


Exploded View
435512 261704 237200 649950
349600 558511
Exploded View

A6UW406FA0

268711 263230A
546810A
W0CZZA

W0CZZB 263230B

Only for training and service purposes


669200
437212
559010 263230C
437210 447910
546810A
546810B

Copyright ©2007 LG Electronics. Inc. All right reserved.


552111

548490 554031A

552116
55211GB

- 253 -
554160A 554160B

55211GA

566000 552203A
435301

435511
554031B
552203B 352112
137213
430411 552115B

552113
552115A 661400

LGE Internal Use Only


P/NO : 3828A20097W NOVEMBER, 2007