Bollards are used for mooring and towing purposes. Their strength check forms an important
exercise in tow gear selection and design
This spreadsheet can be used to perform a strength check of a bollard under a given line pull
Though the spreadsheet shows a double bollard, it can be used as effectively for a single bollard
as well
The input cells are in blue and in the 'Inputs' spreadsheet.
Once all inputs are given, the strength check is performed automatically by the spreadsheet
Assumptions:
1. The weld everywhere is assumed as fillet weld
2. The weld between bollard pipe and base frame is considered as fillet weld on two sides
References
1. AISC ASD 9th Ed
www.thenavalarch.com
For feedbacks, write to thenavalarch@gmail.com OR info@thenavalarch.com
BOLLARD STRENGTH CHECK
Bollard Pipe
INPUTS F(Force on Bollard)
ALLOWABLE STRESS1
Parameter Symbol Formula Value Unit A
Steel Yield Stress σy 235 MPa
Weld Yield Stress σyw 480 MPa
θ (Angle of Force)
Allow. Bearing Stress σb 0.9σy 211.5 MPa
Allow. Shear Stress τa 0.4σy 94 MPa
Allow. Tensile Stress σt 0.6σy 141 MPa
B Y B
Allow. Bending Stress σbend 0.6σy 141 MPa
HP (Height of Force
Allow. Von Mises Stress σc 0.75σy 176.25 MPa
from top of Base
Allow. Weld Stress σW 0.3σyw 144 MPa Frame)
BOLLARD GEOMETRY
Parameter Symbol Formula Value Unit
Outer Diameter of Bollard Pipe Do 325 mm
HB (Height of
Thickness of Bollard Pipe tP 18 mm
Base Frame)
Outer Length of Base Frame LB 1300 mm
X-Axis Y-Axis
Outer Width of Base Frame WB 430 mm
Thickness of Base Frame tB 12.00 mm LB (Outer Length of Base Frame) Section A-A
Height of Base Frame HB 125 mm A
WELD THICKNESS
Parameter Symbol Formula Value Unit Bollard Pipe
F(Force on Bollard) Thickness tP
Thickness of Weld between bollard pipe and base frame tw1 10 mm Y-Axis
Thickness of Weld between base frame and deck tw2 10 mm
FORCES
Parameter Symbol Formula Value Unit WB (Outer Width of DI(Inner Dia) DO(Outer Dia)
Force on Bollard F 20 MT Base Frame)
Load Safety Factor SF 1.25
Angle of Force θ 0 degrees Bollard Pipe Section B-B
Height of Force measured from top of base frame HP 480 mm X-Axis
1
As per AISC ASD 9th Ed