Escolar Documentos
Profissional Documentos
Cultura Documentos
SYMPTOM
SC672-11 or -12 (Controller start up error) occurs.
SC672-11: Communication error between operation panel and CTL after machine is powered on.
SC672-12: Communication error between operation panel and CTL after normal start-up.
Note
- SC672 does not appear on the SMC report, since it is not logged.
- The operation panel (Normal Operation Panel / Smart Operation Panel)
communicates with the controller via a USB cable and IPU. SC672 is triggered when
the panel cannot communicate with the controller.
- Applicable models: MP C401
CAUSE
Possible causes include:
1. Failure of USB communication path (USB cable, IPU)
2. Data corruption of CTL onboard Flash memory
3. Poor supply voltage for CTL onboard ASIC
4. Firmware bug related to energy saving system
5. Defective CTL onboard converter
6. Defective CTL onboard resistors
7. FCU start-up error
SOLUTION
In the f eld
Do the following.
1. Turn the machine power OFF/ON.
2. Check the Power Saving System firmware version.
- If this firmware is older than ver. F.20, update it to ver. F.20 or newer.
3. Re-connect the USB cable and the harness between the IPU board and the
operation panel.
4. Do the action in the flowchart on the next page to determine the cause and
best course of action.
Parts needed:
- USB cable
- Memory (DIMM on the CTL
- CTL board
- IPU board
- Operat on panel
- FCU board
Important
If SC991 (SCS: scs time count level c ) appears in the SC history, do the following.
(1) Replace the USB cable.
(2) Replace the controller board.
Technical Bulletin PAGE 3/11
Model: Z-C2 Date: 27-Jul-16 No.: RD193056
SC672 Occurs
Yes No
A
Technical Bulletin PAGE 6/11
Model: Z-C2 Date: 27-Jul-16 No.: RD193056
8. Remove the screws (x7) fixing the metal plate with the scanner unit on the left
hand side.
10. Remove the screws (x2) fixing the metal plate with the scanner unit on the
right hand side.
Technical Bulletin PAGE 8/11
Model: Z-C2 Date: 27-Jul-16 No.: RD193056
15. Remove the harness and the USB cable (clamp x4).
E Operation panel
Do the following procedure step-by-step if the USB cable replacement does not
solve the symptom. Stop the procedure at any step if the symptom is solved.
NOTE
If the problem s not solved, please escalate n the standard process w th
the follow ng nformat on attached for nvest gat on
- SC sub code (SC672-11 or 12
- Date/t me of problem occurrence
- Debug logs (Controller, Eng ne, Operat on panel
- Factor(s that tr gger the problem (ex. SC672-11 occurred 3 m nutes
after tun ng ON the ma n power sw tch.
- Occurrence frequency (example One out of ten t mes when turn ng
ON the ma n power sw tch
- Replaced parts
- Date/t me of when the parts were replaced