Smart Sensor

DL Series: Smart Environmental Monitoring


CO / CO2 / HCHO / Temperature / Humidity / Dew Point

The DL series of Data Logger devices provide RS-485, Ethernet/PoE, USB, Wi-Fi and BLE
communication interface for smart environmental monitoring. The DL-300 series can be used to
record CO, CO2, HCHO, Temperature, Humidity and Dew Point information, including date and
time stamps, and are able to store up to 450,000 downloadable records.

DL-10/DL-100 Series: Temperature (T.)/Humidity (RH)/Illuminance


(I.)

Features

 Measurement Ranges: -20 ~ +60°C and


Applications 0 ~ 100% RH
 Accuracy:
 Transportation of food or o +/-0.4°C; +/-3.0% RH for non-P
pharmaceuticals verison
 Food and beverage o +/-0.3°C; +/-1.8% RH for P version
 LCD Display Shows Temperature,
industry (HACCP)
Humidity and Module ID
 Blood stations, pharmacies
 10 ~ 30 VDC Power Input
 Building and energy  IP66 Waterproof
management  Data Logger Can Store Up to 4088
 Warehouses Temperature and Humidity Records
 Museums, archives,  RS-485 Communication interface
galleries  DCON or Modbus RTU Protocol
 Windows Software Included

Perzhin kara Co. | Representation of ICPDAS in the Middle East


Address: Sheikh Zayed Rd, Al Mossa Tower 2, Suite 337 P.O. Box: 998, Dubai, UAE
Phone: +971-434920111 | Email: Support@perzhin.com | Info@perzhin.com |Website: www.icpdas.me
Smart Sensor

DL-10/DL-100 Series: Temperature (T.)/Humidity (RH)/Illuminance


(I.)

Features

 Measurement Range: -20 to +60°C and 0 to 100% RH


 LCD Display Shows Temperature, Humidity, Relative Humidity, Date and
Time
 Able to store up to 600,000 records with date and time stamps
 Free Software Utility, iOS APP and Android App Included
 Supports the Modbus TCP and MQTT Protocols
 Includes redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC
input (DL-101-E Only)
 PhotoMOS Relay Output for Alarm Devices or IAQ Device Control (DL-
101-E Only)
 Supports Web Configuration and Firmware Update via Ethernet
 IP 66 Protection Approval
 DIN-Rail or Wall Mounted

Perzhin kara Co. | Representation of ICPDAS in the Middle East


Address: Sheikh Zayed Rd, Al Mossa Tower 2, Suite 337 P.O. Box: 998, Dubai, UAE
Phone: +971-434920111 | Email: Support@perzhin.com | Info@perzhin.com |Website: www.icpdas.me
Smart Sensor

DL-300 Series (CO/CO2/H2S/NH3/HCHO/TVOC/Temperature/Humidity)

Features

 Able to record CO, CO2, HCHO, TVOC, NH3, H2S, Temperature, Humidity,
and Dew Point Measurements
 Non-dispersive Infrared (NDIR) CO2 Sensor
 Electrochemical Sensor
 2.8" LCD Touch Screen
 Up to 450,000 records with date and time stamps
 Touch-screen and Web-based Configuration Interface
 Simple and Powerful Software Utility, iOS APP and Android App Included
 Able to Display Multilingual Messages on the Screen
 Supports the DCON, Modbus RTU/TCP, and MQTT Protocols
 Includes RS-485/Ethernet/PoE Communication Interfaces
 Relay Output for Audible/Visual Alarm or IAQ Device Control
 Includes redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC input
 IP 65 Protection Approval

Perzhin kara Co. | Representation of ICPDAS in the Middle East


Address: Sheikh Zayed Rd, Al Mossa Tower 2, Suite 337 P.O. Box: 998, Dubai, UAE
Phone: +971-434920111 | Email: Support@perzhin.com | Info@perzhin.com |Website: www.icpdas.me
Smart Sensor

CL Series: Smart Environmental Monitoring


PM2.5 / CH4 / HCHO / CO / CO2 / Temperature / Humidity / Dew Point

Fine particulate matter (PM2.5), gas (CH4), HCHO, and CO affect human’s health and safety.
Monitoring the concentration of CH4, PM2.5 and CO can let people stay away from danger, enjoy
a healthy life, and reduce medical costs. CO2 is a reference for indoor air quality, the high
concentrations of CO2 increase possibility to harm people's health. According to the report,
controlling the concentration of CO2 in air conditioning equipment can save up to 50% of energy.
The CL series can detect CH4, HCHO, PM2.5, CO, CO2, Temperature, Humidity and Dew Point
information.

CL-201-E/CL-202-E/CL-203-E/CL-204-E/CL-207-E/CL-208-E

Remote CO/CO2/HCHO/TVOC/Temperature/Humidity/Dew
Point Data Logger Module

 Able to record CO, CO2, HCHO, TVOC,


Temperature, Humidity and Dew Point
Measurements
 Non-dispersive Infrared (NDIR) CO2 Sensor
 HCHO : Electrochemical Sensor
 VCO : Metal-Oxide Sensor
 Up to 450,000 records with date and time stamps
 Supports the DCON, Modubs RTU/TCP, and MQTT
Protocols
 Includes RS-485/Ethernet Communication
Interfaces
 Relay Output for Alarm or IAQ Device Control

Perzhin kara Co. | Representation of ICPDAS in the Middle East


Address: Sheikh Zayed Rd, Al Mossa Tower 2, Suite 337 P.O. Box: 998, Dubai, UAE
Phone: +971-434920111 | Email: Support@perzhin.com | Info@perzhin.com |Website: www.icpdas.me
Smart Sensor

CL-211-E/CL-212-E/CL-213-E

Remote PM2.5/CO/CO2/Temperature/Humidity/ Dew Point


Data Logger Module

 Able to record PM2.5, CO, CO2, Temperature,


Humidity and Dew Point Measurements
 Non-dispersive Infrared (NDIR) CO2 Sensor
 Up to 450,000 records with date and time stamps
 Supports the DCON, Modubs RTU/TCP, and MQTT
Protocols
 Includes RS-485/Ethernet Communication
Interfaces
 Relay Output for Alarm or IAQ Device Control

Perzhin kara Co. | Representation of ICPDAS in the Middle East


Address: Sheikh Zayed Rd, Al Mossa Tower 2, Suite 337 P.O. Box: 998, Dubai, UAE
Phone: +971-434920111 | Email: Support@perzhin.com | Info@perzhin.com |Website: www.icpdas.me
Smart Sensor
PIR Series: Motion Detection
PIR series modules have the ability to detect infrared waves generated by the human body within
a diameter of approximately 8 meters, with a coverage area of 360° for indoor motion detection.
The modules can be configured to automatically switch on a light if motion is detected. The
modules also contain a temperature and humidity sensor for measuring indoor temperature and
humidity, or it can be configured to activate a fire alarm. A wide range of interface connections
can be selected to suit individual needs, including RS-485/Ethernet/Wi-Fi, provide support for
the DCON and Modbus RTU/TCP protocols, and can be easily integrated into existing
HMI/SCADA/central control systems.

PIR-230-E/PIR-230-BLE/PIR-230-WF PIR-130-AC/PIR-130-DC

Motion, Temperature, and Humidity Sensor PIR Motion Sensor and Temperature
Module Sensor Module

 Adjustable Time-Delay / Lux / Sensitivity  360° Motion Detection Up to 8 m


 Internal Photosensor for Smart Switch Diameter Range
Control  Time-Delay / Lux. / Sensitivity Adjustable
 LED Indicator for PIR/Temperature Sensor  Photo Sensor Inside for Smart Switch-on
 Temperature Sensor for Measuring Room Control
Temperature  LED Indicator for PIR/Temperater Sensor
 Suitable as either Temperature or Fire  The Temperature Sensor for Measuring
Alarm Room Temperature or Fire Alarm
 Relay Output Can be Used to Control  Relay Output Can be Used to Control
Light Via the PIR/Temperature Sensor the Light Via the PIR/Temperature Sensor
 Suitable for loads up to 1500 W  Up to 1500 W Incandescent and 300 W
(Incandescent) and 300 W (Fluorescent) Fluorescent (T8) Loading Capability
 Fluorescent (T8) Loading Capability  RS-485 Communication Interface
 Wide range of Communication  DCON and Modbus RTU Protocols
Interfaces and Protocols  Ceiling Surface Mount Design
 Compatible with IEEE802.11b/g/n
standards (PIR-230-WF Only)
 Support infrastructure and limit-AP
modes for wireless networks (PIR-230-WF
Only)
 Ceiling or Surface-Mount Design

Perzhin kara Co. | Representation of ICPDAS in the Middle East


Address: Sheikh Zayed Rd, Al Mossa Tower 2, Suite 337 P.O. Box: 998, Dubai, UAE
Phone: +971-434920111 | Email: Support@perzhin.com | Info@perzhin.com |Website: www.icpdas.me
Smart Sensor

iSN Series: Liquid Leak Detection Module


The iSN Liquid Leak Detection Module is a low-cost intelligent liquid leak detection device that
can be used to directly control Relay Output. No additional conversion module is needed and the
iSN-101 can be easily integrated with a variety of monitoring systems to achieve remote alarm
and remote device control. The iSN-101 Liquid Leak Detection module can be used to monitor
double-core leader cable lengths of up to 500 meters, and can be used with both the sensor cable
and its included water leakage probe. If liquid is detected, the controller immediately activates
the output relay - the normally open, normally closed passive output signal. The module can be
easily integrated with other collection hosts connected to the network.

iSN-101/iSN-101/DIN

Liquid Leak Detection Module

 Liquid Leak Detection


 Leak detection triggers and audible alarm
 A mute button to silence the alarm
 Two LED indicators to display the status of the
power and the alarm
 A configurable Output Relay
 Leader cables and Sensor Cable can be up to
500 meters
 Adjustable detection sensitivity
 Supports the DCON and the Modbus RTU
Protocols
 Embedded Dual Watchdog
 Wide Operating Temperature Range: -25 to +75°C
 Tiny Form Factor with Easy Screw Mounting