Indoor Branch Pipe

Heat insulation
Name Gas side joints Liquid side joints
Model 38VF008H116010 38VF010H116010 38VF012H116010 38VF014H116010 38VF016H116010 material
Model 38VW008H117010 38VW010H117010 38VW012H117010
Power supply V-Ph-Hz 460V 3Ph ~ 60Hz 460V 3Ph ~ 60Hz 460V 3Ph ~ 60Hz 460V 3Ph ~ 60Hz 460V 3Ph ~ 60Hz

ID:19.1
Power supply V-Ph-Hz 220V 3Ph ~ 60Hz

(ID:15.9)

ID:12.7
OD:19.1
ID:9.5

OD:9.5

ID:6.4

ID:19.1

OD:19.1
ID:15.9
kW 25.2 28 33.5 40000 45000

ID:9.5

OD:12.7
W 25200 28000 33500 Capacity BJF-224-
Capacity Btu/h 86000 95500 114300 136500 153500 CM(i) FULL DC INVERTER
Btu/h 86000 95500 114300 Cooling (*1)
Cooling (*1)

ID:9.5

ID:6.4
OD:9.5
Input kW 5.875 7.053 8.793 11299 13235

ID:12.7
(2 sets)

OD:19.1
Input W 4800 6100 8000

(ID:15.9)
EER kW/kW 4.29 3.97 3.81 3.54 3.4
EER W /W 5. 25 4. 59 4. 19

ID:22.2

(ID:19.1)

ID:15.9
OD:22.2
kW 27 31.5 37.5 45000 50000

ID:12.7

ID:9.5
OD:12.7

ID:6.4
W 27000 31500 37500

ID:22.2
ID:9.5

OD:22.2
Capacity

ID:25.4
ID:12.7

OD:12.7
Capacity Btu/h 92100 107500 128000 153500 170600 BJF-330-
Btu/h 92100 107500 128000 Heating (*2) CM(i)
Heating (*2) Input kW 6.15 7.554 8.993 11194 12788
Input W 4450 5830 7800 (2 sets)

ID:6.4
ID:9.5
OD:12.7

ID:15.9

ID:12.7
OD:22.2

(ID:19.1)
COP kW/kW 4.39 4.17 4.17 4.02 3.91
C OP W /W 6. 07 5. 4 4. 81
Q uantities 1 1 1+1 1+1 1+1

OD:28.6
Quantities 1

ID:28.6

ID:22.2
ID:19.1
OD:15.9

ID:9.5
Compressor

ID:15.9

(ID:12.7)

OD:28.6
B r and H itac hi H itac hi H itac hi H itac hi H itac hi

ID:28.6
ID:31.8
ID:19.1

OD:15.9
ID:15.9
Type DC Inverter
BJF-710-
T ype D C inver ter D C inver ter D C inver ter D C MOT OR D C MOT OR CM(i)
Brand Hitachi Fan motor
Brand Panasonic&Nidec Panasonic&Nidec Panasonic&Nidec Panasonic&Nidec Panasonic&Nidec (2 sets)

ID:6.4
ID:9.5
Drainage pipe outside diameter in.(mm) Ф25/64( Ф10)

OD:15.9

ID:15.9
ID:19.1
OD:28.6

ID:22.2
(ID:12.7)
3
Outdoor air flow CFM(m /h) 6604(11242) 6604(11242) 9185(15620) 9185(15620) 9185(15620)
Water side connecting pipe in.(mm) 1-1/4(DN32) inner groove

ID:19.1

(ID:15.9)

ID:12.7
OD:19.1

ID:34.9
0~20 (default) 0~20 (default) 0~20 (default) 0~20 (default) 0~20 (default)

OD:34.9

ID:28.6

ID:22.2
Outdoor sound level(*3) dB ( A) 51 52 52
ID:19.1

External static pressure Pa


OD:19.1
ID:22.2

ID:38.1

ID:34.9

OD:34.9
20~40 (optional) 20~40(optional) 20~60 (optional) 20~40 (optional) 20~40 (optional) BJF-1344-
Dimension(W×H×D) mm 780×1000×550 CM(i)

OD:34.9

ID:28.6

ID:22.2
Outdoor sound level (*3) dB(A) 57 57 59 61 62

ID:19.1
(2 sets)

ID:12.7

ID:9.5
Main unit
OD:19.1

(ID:15.9)
Packing (W×H×D) mm 845×1170×600 Dimension(W×H×D) (960×1615×765) (960×1615×765) (1250×1615×765) (1250×1615×765) (1250×1615×765)

Packing(W×H×D) (1025×1790×830) (1025×1790×830) (1305×1790×820) (1305×1790×820) (1305×1790×820)

ID:44.5
Net/Gross weight kg 146/155

ID:41.3

ID:34.9
Outdoor Unit
ID:22.2

(ID:19.1)

ID:15.9
OD:22.2
ID:22.2

Net/Gross
OD:22.2
ID:25.4

Charged refrigerant type and volume kg R410A / 2 lbs.(kg) 466/485(212/220) 466/485(212/220) 634/678(288/308) 634/678(288/308) 634/678(288/308)

ID:44.5

ID:41.3

OD:41.3
weight BJF-E1344
Throttle type EXV -CM(i)
Charged refrigerant type and
kg R410A / 10 R410A / 10 R410A / 12 R410A / 15 R410A / 15

ID:41.3

ID:34.9
Excessive operating pressure MPa 4.4/2.6 volume (2 sets)
ID:15.9

ID:12.7
OD:22.2

(ID:19.1)

Throttle type EXV EXV EXV EXV EXV


Refrigerant piping Liquid side/ Gas side in.(mm) Ф9.53/ Ф22.2 Ф9.53/ Ф22.2 Ф12.7/ Ф25.4
Excessive operating pressure MPa 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6

ID:63.5

OD:54
ID:54
Main unit water inlet temp. °F (°C) 44.6-113°F (7 -45°C)

ID:41.3
ID:25.4
ID:22.2

OD:22.2

(ID:19.1)

Liquid side/ Gas side in.(mm) Ф12.7/ Ф25.4 Ф12.7/ Ф25.4 Ф15.9/ Ф31.8 Ф15.9/ Ф31.8 Ф15.9/ Ф31.8
Main unit ambient temp. range °F (°C) 32-104°F (0 -40°C)
ID:22.2

OD:22.2
ID:25.4

ID:63.5

OD:54
ID:54

Oil balance pipe in.(mm) 1/4( Ф6.4) 1/4( Ф6.4) 1/4( Ф6.4) 1/4( Ф6.4) 1/4( Ф6.4) BJF-E1500-
Main unit ambient humidity Below 80% CM(i)
Ambient Cooling ℉(℃) 23~118.4(-5~48) 23~118.4(-5~48) 23~118.4(-5~48) 23~118.4(-5~48) 23~118.4(-5~48)

ID:41.3
(2 sets)

ID:34.9
ID:15.9
OD:22.2

(ID:19.1)

temperature range Heating -4~75.2(-20~24) -4~75.2(-20~24) -4~75.2(-20~24) -4~75.2(-20~24) -4~75.2(-20~24)


1. The cooling conditions: indoor temp.: 80.6°F (27°C DB), 66.2°F (19°C) WB, outdoor temp.: 95°F (35°C) DB, water inlet temp.: 86°F (30°C), equivalent pipe ℉(℃)
length: 16.4ft. (5m), drop length: 0ft. (0m).
2. The heating conditions: indoor temp.: 68°F (20°C) DB, 59°F (15°C) WB, outdoor temp.: 44.6°F (7°C) DB, 42.8°F (6°C) WB, water inlet temp : 68°F (20°C), 1. The cooling conditions: indoor temperature: 27 ℃DB(80.6 ℉), 19 ℃WB(60 ℉), outdoor temperature: 35 ℃DB(95 ℉), equivalent pipe length: 16.4ft(5m), drop length: Outdoor Branch Pipe
equivalent pipe length: 16.4ft. (5m) drop length: 0ft. (0m). 0m. Gas balance Gas balance Heat insulation
Name Gas side joints Liquid side joints Oil balance material
joint 1 joint 2
3. Sound level: Anechoic chamber conversion value, measured at a point 3.28 ft. (1m) in front of the unit at a height of 3.28ft. (1 m). During actual operation, these 2. The heating conditions: indoor temperature: 20 ℃DB(68 ℉), 15 ℃WB(44.6 ℉) outdoor temperature: 7 ℃DB(42.8 ℉) equivalent pipe length: 16.4ft(5m ), drop length: 0D:31.8 ID:31.8 0D:15.9 ID:15.9
values are normally somewhat higher as a result of ambient conditions. 0m. ID:25.4 ID:34.9 0D:34.9 ID:12.7 ID:19.1 0D:19.1
Q2 Y2
4. Connection piping diameter is based on the condition that the total equivalent liquid length is less than 295.2ft. (90m). Wh en the total equivalent liquid length is 3. Sound level: Anechoic chamber conversion value, measured at a point 3.28ft(1m) in front of the unit at a height of 4.92ft(1. 5m). During actual operation, these values BJC-02- Q4 Q3 Y6 Y3
CM(i) ID:22.2
ID:38.1 Y1 ID:15.9
more than 295.2 ft. (90m), please refer to installation m anual to choose the connection piping diameter. Q1 ID:31.8
are normally somewhat higher as a result of ambient conditions. ID:15.9 ID:19.1
ID:31.8 ID:34.9 0D:15.9 (2 sets)
5. The farthest equivalent pipe length should be equal to or shorter than 131.2 ft. (40m), but it can be up to 295.2ft. (90m) if meet the required c onditions following ID:25.4 0D:31.8 ID:12.7
4. The above data may be changed without notice for future improvement on quality and performance.
part 4 installation sections. 0D:31.8 ID:31.8 ID:38.1 0D:15.9 ID:15.9
The above data may be changed without notice for future improvement on quality and performance. ID:19.1
ID:25.4 ID:22.2 0D:22.2 ID:15.9 ID:19.1
0D:34.9 ID:41.3 ID:12.7
The above data may be changed without notice for future improvement on quality and performance. ID:19.1 ID:6.4
Q2 Y2 Y7 Y4
BJC-03- Q7 Q5 Y6
ID:19.1
CM(i) Y1
ID:38.1 Y1 ID:15.9 ID:15.9
Q1 Q1
ID:31.8 ID:31.8 ID:15.9
ID:31.8 ID:34.9 ID:15.9 0D:15.9 M N P (4 sets)
ID:31.8 0D:15.9
0D:31.8 ID:12.7
ID:25.4 ID:25.4 0D:31.8 ID:12.7

0D:31.8 ID:31.8 ID:38.1 ID:41.3 0D:15.9 ID:15.9


ID:19.1 ID:22.2 ID:19.1
ID:25.4 ID:41.3 ID:44.5 ID:12.7 ID:19.1 ID:22.2 ID:25.4 0D:25.4 ID:15.9
0D:34.9 ID:6.4

Q2 Y2
Q5 Q6 Y6 Y7 Y8 Y5
BJC-04- Q7
ID:22.2
CM(i) ID:38.1 Y1 ID:15.9 ID:15.9
Q1 Q1 Q1 Y1 ID:15.9 Y1
ID:31.8
ID:31.8
ID:34.9 ID:31.8
ID:31.8
ID:31.8
ID:31.8 ID:15.9
0D:15.9
ID:15.9 ID:15.9
0D:15.9
M(Two) N(Two) P(Two) (6 sets)
60HZ
0D:15.9
ID:25.4 0D:31.8 ID:25.4 0D:31.8 ID:25.4 0D:31.8 ID:12.7 ID:12.7 ID:12.7

*7:*All the branch pipe will be shifted to new models ended with "i" (adding insulation blanket) from Jan. Y2014 "

6 7 8
DC Inverter Compressor Indoor Unit Lineup Heat Recovery Ventilation Unit
DC Inverter Compressor Multi-EEV Control Technology Model
Model Type 200 300 400 500 800 1000 1500 2000
Type Air Volume(m³/h)
18 22 28 36 45 56 71 80 90 100 112 125 140 160 200 250 280 400 450 560
All DC inverter high discharge compressors contribute to higher IPLV (capacity *100w)
Multi-EEV Control Technology in one system, each EEV part achieves 480 pulse to adjust flow precisely.
greatly. The highest IPLV is up to 5.8. With all DC inverter compressors, Heat Recovery
Ensure the temperature-controlling precisely and steadily to give a comfortable envrionment. One-way Ventilation ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
series offer a wide operation range from 20Hz to 200Hz. cassette ▲ ▲ ▲▲▲▲▲
Water pump is standard.
Note: Only full inverter series outdoor unit use all DC inverter compressor.
4.39 Two-way
4.29 4.17 4.17
3.97 4.02 3.91 3.89 cassette ▲▲▲▲ ▲▲
3.81 Water pump is standard.
3.54 3.4 3.38 High Efficiency
DC Fan Motor Control Devices
Compact four-
EER Achieved the highest level for series has achieved the highest level for heating COP (4.39) and way cassette ▲▲▲▲
COP Water pump is standard.
Type
Series adopt DC fan motor only. cooling EER (4.29) in the 8HP category.
Lowers running noise and reduces power consumption about 45% especially at low load. 8HP 10HP 12HP 14HP 16HP 18HP Four-way
cassette
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲▲ ▲
Water pump is standard.
Increased by
Full inverter side blow discharge series:
Remote
100 Inverter individual series: Night silent operation mode Low Static
20/22/24/30HP 8/10/12/14/16/18/20/22.4/26kW Pressure Duct ▲▲▲▲▲ ▲ ▲ controller
80 WL-12-CM WL-14-CM
45%
High comfort outdoor unit’s multi-choice of silent mode during the night.
60
Super silent operation mode can reduce sound level further, minimum 45dB (A). ※ Individual Controller
3 3 3 3 3 3
40

EFFICIENCY (%)
▲* ▲* ▲* ▲* ▲* ▲* ▲ ▲ ▲ ▲ ▲ ▲
Water pump is standard.
*3: Models range 22-71 will shift to new structure slim A5. *6: Standard individual controller is
20
-Model 1→X: 6 hours, Y: 10 hours -Model 2→X: 8 hours, Y: 10 hours Medium Static WL-12-CM, other individual
-Model 3→X: 6 hours, Y: 12 hours -Model 4→X: 8 hours, Y: 8 hours Pressure Duct ※ controller need to customise.
200 1000
4 4 4 4 4 4 Wired
Peak value of ambient temp. ▲* ▲* ▲* ▲* ▲* ▲*
MOTOR SPEED (RPM) controller
*4: These slim A5 will be phased in to replace old models range 22-71 A5.
(V type) Water pump is standard
* K series and Individual series use the DC fan WR-10-CM WR-12-CM WR-29-CM WR-90-CM WR-120-CM

motor +AC fan motor.


▲▲▲ ▲
50
180° Sine Wave DC Inverter Control 8hrs 10hrs ▲▲ Centralized Controller
High Static
Full inverter Night silent Mode
Smoothes the rotation of the motor, operation efficiency is improved sharply. Pressure Duct
Max.-10dB(10Hp)
series:8/10/
12/14/16 CRF-10-CM WCRF-10-CM CRC-10-CM CRF-30-CM
/18*HP (Note
: 18HP need Start End
▲▲▲
custmise)

08:00 14:00 22:00 08:00 5 5 5


▲* ▲* ▲*
Notes: Thiss function
Not f can be activated by setting at site. Temperature(load) curve shown in the graph is just an example. *5: customized model. BMS Gateway
Side
ed discharge unit do not have night silent operation mode.
Ceiling & Floor ▲▲▲▲▲▲ ▲ ▲▲ BACNET Gateway MODBUS Gateway LONWORK Gateway
Five prio
priority
o mode lock function
Wall-mounted
S Type ▲ ▲▲▲▲
180° Sine Wave DC Inverter Heating priority mode
mode, cooling priority mode
mode, VIP prio
priority or vote priority mode, heating only
HeaƟng
Ɵng Cooling
Co ling VIP priority
priority Only responds
r sponds Only responds
esponds Network Control
priorityy mode priority
priori y mode or to
o to
o
ault)
(default) vote priority heaƟng
heaƟ g mode cooling
cooli g mode
priority mode, cooling only priority mode. Wall-mounted
C Type ▲ ▲▲▲▲ Software &Hardware
High Efficient δ Structure Heat Exchanger Long Piping Length Auto addressing Ued for network control and power fee calculation.

Wall-mounted
Total pipe length can reach to 1000m. R Type ▲▲▲
12 ° C sub-cooling degree makes the cooling capacity increased efficiently. Thus, the total piping length becomes
longer, reach up to 1000m.
▲ ▲▲▲▲▲▲ Accessories
Floor standing

▲ ▲▲▲▲▲▲ Hotel card Infra-red NIM ODU alarm module AHU kit Data converter digitalpower meter

Console ▲ ▲▲▲
Meanwhile, the innovative design makes heat exchanger high
efficient and also simplifies the pipeline of outdoor unit to realize

Maximum piping actual length 175m


90m
Outdoor unit-Indoor unit drop height 110m*
compact design and low weight. ▲ ▲

Indoor unit-Indoor unit


drop height 30m
Fresh Air
*Level difference: processing unit
outdoor unit is down:110m
outdoor unit is up:70m ▲▲▲

2 3 4 5