Você está na página 1de 14

REVIT ARCHITECTURE - FCP QUESTIO

SL NO QUESTIONS

The actual display of editable value must be same as the value set in the projects
1 units.
TRUE / FALSE

When you place curser for creating additional level, the dimension display on screen
2 is
A) Listening. B) Temporary C) Permanent D) None of the above

When you move the buble end out of line, the effect appears only in that view. No
3
other views are affected. TRUE / FALSE

The segments created from dragging the bubble have a solid line style which can
4
not be edited. TRUE / FALSE

To create new level element type, open one of the following revit family template file
5
A) Level head.rft B) Grid head.rft C) Level head.rte D) Grid head.rte

While creating a level, in option bar, if make plan view option is unmarked, then
6 corresponding floor plan view is not generated
TRUE / FALSE

If the permenant dimension is locked (constraints), when a single level is moved, all
7 the relevant level lines are moved.
TRUE / FALSE

In Architecture tab, while selcting wall tool, Wall sweep and Reveal get activated
8
only in 3D view. TRUE / FALSE

When you draw a foundation wall type, the option name is displayed as
9
A) Width B) Height C) Depth D) Size

The Wall type name will automatically get updated when its parameters are
10
changed. True / False

While creating arc wall, in option bar, if keep concentric is selected, then the radius
11 centre point will not get changed.
TRUE / FALSE
While drawing a straight wall, what is to be done to create a arc in wall end
12 A) select chain option. B) Select fillet option
C) Draw a fillet wall D) Draw a tangent wall

13 A Negative Value moves the sweep toward the wall core. TRUE / FALSE

14 Can we use same profile for Sweeps and Reveals?

15 Is it possible to give Materials to Reveals?

When you select arc wall, howmany angle dimesnsion is visible


16
A) 2 B) 3 C) 1 D) none of the aboe
How much thickness can be applied for membrane layers in wall type. A) 5mm to
17
10mm B) below 5mm C) Zero D) Above 10mm
The structure of vertically compound wall is defined using
18 A) Layer and region. B) Only layer. C) Either layer or region.
D) Only region

In vertically compound wall, the region's thickness can be changed in the row that is
19
assigned to it. TRUE or FALSE
You can not choose materials or thickness for core boundry layers
20
TRUE or FALSE
All wall joints less than ----------- are mitered
21
A) 90° B) 30° C) 45° D) None of the above

In wall instance property, the "Top extension distance" is activated for the purpose of
22 A) To extend wall height beyond level line. B) To extend a layer. C) To increase
wall thickness. D) None of the above

In wall vertically compound wall, unlocked layers must be adjacent


23 TRUE or FALSE

When location line exterior is selected, always the location line displays on the
24
exterior side of the wall irrelevant of how you draw the wall. TRUE / FALSE

In revit wall layers if the row does not have any region assigned to it, the thickness
25
is zero TRUE/FALSE

26 In wall layers a row can be assigned for more than one layer TRUE/FALSE

27 A membrane layer has got Thickness TRUE/FALSE

28 When u create a wall schedule the vertically stacked wall can be scheduled TRUE/F
29 The sub walls (In stacked) can be scheduled TRUE/FALSE

30 When u draw grid lines the grid numbers automatically generatd TRUE/FALSE

31 The vertically stacked wall can be seperated. TRUE / FALSE

After breaking up of a Vertically stacked wall, the walls again can be reassembled.
32
TRUE / FALSE
Grid lines are
1) Finite planes
33
2) Their extents can be dragged in Elevation views
A) TRUE B) FALSE C) Only point 1 is correct D) Only Point 2 is correct

34 The move tool will not work if the Element is pinned

While moving a component which of the following key is used to constrain it


35
A) Control key B) Shift key C) Space bar D) None of the above

You can use the arrow key to move the level-based element up or down.
36
TRUE / FALSE

If the wall is moved, the furniture placed near the wall moves along with the wall.
37
This is possible using an option. TRUE / FALSE

Use create similar tool to add a new instance of a selected element.


38
TRUE / FALSE

For arc lines, the radius remains at a constant offset from the arc wall, even if the
39
radius of the wall changes. TRUE / FALSE

Using copy to Clip board option, you can copy the Refernce level in the Family
40
Editor. TRUE / FALSE

Use the -------------- tool to add a new instance of a selected element


41
A) Create similar B) Copy C) Move C) Array D) Mirror

Use the copy to Clipboard tool, when you need to swith views before placing the
42
copies. TRUE / FALSE

43 Using Rotate tool, the Window can rotate without their wall

44 You can also rotate an Element using Listening dimension. TRUE / FALSE

Reverse the position of a selected model element is


45
A) Copy B) Mirror C) Move D) Rotate
Inserts such as Doors / Windows can be Mirrored without their host.
46
TRUE / FALSE

When you use Pick mirror axis, you can pick anything in the model such as
47
elements, model etc. TRUE / FLASE
48 Arrays are not supported for most annatation symbol. TRUE / FALSE

To create several instance of one or more elements and manipulate them


49 simutaneously
A) Copy B) Copy with Multiple option C) Array D) Scale

Group & Associate appears in option bar when select a tool


50
A) Copy B) Array C) Scale D) Trim / Extent

You can group together detail components and model components.


51
TRUE / FALSE

The default shortcut key for Find / Replace tool is


52
A) FN B) FR C) FAR D) FRP

The scale tool can not be used to modify


53
A) Line B) Wall C) Floor D) Images

Doors can be added in


54 A) Only in plan B) Plan & Elevation C) Plan, Elevation & Section D) Plan, Section,
Elevation & 3 D

The default shortcut key for Place a Component tool is


55
A) PC B) CM C) COM D) CN

To unpin a pinned element, just click the pushpin control in the drawing area.
56
TRUE / FALSE

57 In Revit, Doors & Windows are not hosted components. TRUE / FALSE

To make the window in same position on the opposite walls use


58
A) Copy B) Mirror C) Align D) Trim

When Tape measure tool is used to measure a inclined wall, the length and the
59
angle from horizintal is displayed. TRUE / FALSE

The default shortcut key for Modify tool is


60
A) MD B) MO C) M D) MF

The default shortcut key for Keyboard shortcuts tool is


61
A) KEY B) KB C) KS D) NONE

62 Chain option is not available for Tape measure tool. TRUE / FALSE

The default shortcut key for Mirror - Pick axis tool is


63
A) MM B) MP C) MR D) MA

The default shortcut key for Rotate tool is


64
A) RT B) RO C) RE D) None
Which is the element that can not split
65
A) Walls B) Floor C) Lines D) Beams

66 To create a sloped suface, use slope arrow tool in Floor. TRUE / FALSE

To place a component in a sloped floor enable the


67
A) Only horizontal B) Work plane based C) Reference plane D) Apply slope

While placing a component, if you use the space key, the component rotate 90°
68
Clockwise

69 Roof can be made from Mass instances also. TRUE or FALSE

The cut off option is available for Roof in


70
A) Type proporty B) Instance property C) Option bar D) Edit Roof

The split line tool will become active when you edit the
71
A) Wall B) Floor C) Roof D) Staircase

One of the option under curved edge condition tool is (For floor modification)
72
A) Sloped surface B) create curve C) Project to side D) Curved edge

To remove floor shape modifications and reset to original sate, click Reset shape.
73
TRUE / FALSE

While using Join geometry tool, the first selected element is not extended.
74
TRUE / FALSE

To create a new profile for Gutter, open


75
A) .rvt file B) .rte file C) .rft file D) rfa file

The Join / Unjoin roof tool can be used between Roof created using Roof by foot
76
print and Roof by extrusion. TRUE / FALSE

77 Roof by extrusion profile should be closed profile. TRUE / FALSE

78 Dimensions are view-specific elements. TRUE / FALSE

The permenant dimension can be modified, if the relevant element is selected


79
TRUE or FALSE

80 How many types of Dimension string types are available

Spot elevation tool can be used in


81
A) Floor plan B) Elevation & 3D view C) Only in Elevation D) None of the above

When you place permenant linear or angular dimensions, a lock control appears
82
with the dimension. TRUE OR FALSE
Which is the correct statement
83 A) EQ symbol represents Equality constraints B) EQ symbol represents equal
dimesnion.

Views provide ------------ picture of a building model.


84
A) Similar B) Unique C) Detailed D) variety of

What is the default cut plane elevation for Floor plan.


85
A) 1500 mm B) 2100 mm C) 900 mm D) 1200 mm

In view range option, one of the below is not belongs to primary range
86
A) Top B) Cut plane C) Level D) Bottom

View range are view specfic and can be copied to other views.
87
TRUE or FALSE

To add a framing elevation view, you must have a grid in your view.
88
TRUE or FALSE

What is the view which cut through the model.


89
A) plan B) section C) Elevation D) 3D view

One of the below is not belongs to the type of section views


90
A) Building section B) Wall section C) Detail D) Floor plan

You can not split sections into segments tHat are orthogonal to the view direction.
91
TRUE / FALSE

What is the view where components that are farther away appear smaller and
92 components that are closer appear larger.
A) Perspective view B) Orthographic view C) 3D view D) Isometric view

Orthographic 3Dviews shows the building model in a 3D view where all components
93 are the same size regardless of the camera's distance.
TRUE / FALSE

What is the shortcut key to invoke the steering wheel.


94
A) F2 B) F6 C) F8 D) F10

95 Section box is available only for 3D view. TRUE / FALSE

96 Tags and keynotes can not be placed in a 3D view that has been locked

The perspective 3D view do not support the annotation crop region.


97
TRUE / FALSE

To blend the line color of an element with the background color of the view, go to VG
98 and edit the below
A) Transperancy B) Cut line C) Halftone D) Cut pattern
Project views and View Templates are linked. When a template changes, all views
99
created from that template update automatically. TRUE / FALSE

100 View template can be transferred from one project to another. TRUE / FALSE

101

MS PROJECT

SL NO QUESTIONS

When you update the progress, if you change the progress %, the remaining
1
duration also changes automatically. TRUE OR FALSE

To leave incomplete task at 0 %, select this option


2
A) 0 % or 100 %. B) 0% - 100%

When you update the progress, project do not update the manually scheduled task.
3
TRUE / FALSE

One of the below is not belongs to the types of percent complete


4 A) Percent work complete B) Percent complete C) Work complete D) Physical
percent complete

How many types of percent complete in MSP


5
A) 3 B) 4 C) 2 D) 5

Multiple baselines Gantt view enable you to see the first 3 baselines.
6
TRUE or FALSE

7 In Default, updating % complete automatically updates % work complete


To evaluate the progress of work in a project, compare
8 A) EV with PV B) EV with AC C) PV with AC D) None of the above

What is BAC
9
A) Baseline cost B) Budgeted actual cost C) Budgeted at completion

SPI is equal to
10
A) EV / PV B) PV / EV C) EV / AC D) EV - PV
TURE - FCP QUESTIONS & ANSWERS

ANSWER CHAPTER PAGE REMARKS STATUS

Even you set project units rounded off to 1


0 2 17 inch, the actual display may be for fractional SENT
inches

A temporay vertical dimension display


B 2 19 SENT
between the cursor & level line

1 2 22 SENT

1 2 22 SENT

A 2 24 SENT

1 2 SENT

1 2 30 SENT

1 2 31 SENT

C 2 32 SENT

When you change wall width, the wall type


0 2 SENT
has to be duplicated.
If keep concentric is selected, radius centre
point is fixed and arc connecting end will
0 2 38 move. SENT
If vice versa, radius centre will move and wall
connection will not move
B 2 37 SENT

1 2 49 SENT

Yes. We can use 2 SENT

No 2 50 SENT

B) 3 2 37 SENT

C) Zero 2 40 Membrane layer should have zero thickness SENT

C) Eiher layer or
2 43 SENT
region

0 2 43 SENT

1 2 41 SENT

D) None of the
2 42 Less than 20° is correct SENT
above
In type property the wall layer can be
unlocked and then this "Top extension
B 2 45 SENT
distance" is activated for increasing a
particular layer.

1 2 45 SENT

This depends on clockwise or


0 2 33 SENT
anticlockwise rotation

1 2 47 SENT

0 2 48 SENT

0 2 48 SENT

0 2 55 SENT
1 2 55 SENT

1 2 56 SENT

1 2 56 SENT

0 2 55 SENT

1 2 56 SENT

1 3 63 SENT

B 3 63 SENT

0 3 63 SENT

1 3 66 SENT

1 3 67 SENT

1 3 67 SENT

0 3 68 SENT

A 3 67 SENT

1 3 67 SENT

0 3 70 SENT

1 3 72 SENT

B 3 72 SENT

1 3 72 SENT

0 3 73 Only Reference plane or line SENT


1 3 73 SENT

C 3 73 SENT

B 3 74 SENT

0 3 81 Page no. as per Revit 2014 book ↓ SENT

B 3 98 SENT

Scale will work only for Lines, walls, images,


C 3 84 DWG & DXF imports, reference plane, SENT
position of dimenstion.

D 3 91 SENT

B 3 98 SENT

1 3 91 SENT

0 3 92 SENT

C 3 95 SENT

1 3 97 SENT

A 3 98 SENT

C 3 98 SENT

0 3 97 SENT

A 3 98 SENT

B 3 98 SENT
B 3 102 SENT

1 4 105 SENT

B 4 110 SENT

0 4 114 Rotate Anticlockwise SENT

1 4 118 SENT

B 4 118 SENT

B 4 128 SENT

C 4 129 SENT

1 4 130 SENT

0 4 131 SENT

C 4 132 SENT

1 4 133 SENT

0 4 139 SENT

1 5 143 SENT

1 5 144 SENT

3 5 148 Continuous, Ordinate, Baseline SENT

B 5 150 SENT

1 5 156 SENT
A 5 156 SENT

B 5 162 SENT

D 5 162 SENT

C 5 163 SENT

1 5 164 SENT

1 5 168 SENT

B 5 170 SENT

D 5 170 SENT

0 5 172

A 5 173

1 5 173

C 5 175

1 5 176

0 5 177

1 5 178

C 5 181
0 5 183

1 5 183

ANSWER CHAPTER PAGE

1 9 128 sent

A 9 130 sent

0 9 131 sent

C 9 132 sent

A 9 132 sent

1 9 133 sent

1 9 132 sent

A 10 141 sent

C 10 141 sent

A 10 141 sent

Você também pode gostar