Você está na página 1de 1

UFPA

ECO-COMPÓSITO

Test Report
Machine: Emic DL2000 Load cell: Trd 24 Extensometer: - Date: 12/20/2016 Time: 15:04:14 Job n. 0469
Program: Tesc version 3.01 Test Method: FLEXÃO
Sample Ident.: >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>A: CERAMICA B: C:

Specimen Elast.Modul. Force Force


@Max. Load @Max. Load
(MPa) (N) (kgf)

Spc 1 41,970 214,074 21,83


Spc 2 27,233 121,762 12,42
Spc 3 18,488 95,584 9,75
Spc 4 24,107 104,540 10,66
Number Spcs 4 4 4
Mean 27,95 134,0 13,66
Median 25,67 113,2 11,54
Std. Dev. 10,02 54,48 5,556
Coeff.Var. % 35,86 40,66 40,66
Min. Value 18,49 95,58 9,747
Max. Value 41,97 214,1 21,83

Force (N)
290,0

232,0

174,0

116,0

58,0

0,0
0,000 0,600 1,200 1,800 2,400 3,000 Deformation (mm)
Spc 1 Spc 2 Spc 3 Spc 4 Spc 5