Você está na página 1de 10

TECHNICAL NOTE

Number: GE-URF-TN-0006

Date: 10/6/19 Client: INPEX Project: ICHTHYS


Title: Orientation of BDC-1A-06 Well Jumper Downfacing Structure
Equipment: VCCS Downfacing Size 450 Dualbore, P/N: N113001-E289A
N113002-4502-01, VCCS Downfacing Structure Dualbore Assembly Drawing
N042042-0009, VCCS Downfacing Structure Assembly Procedure
N113001-E289A, VCCS Downfacing Assembly Top Level Drawing
References: N042071-0001, Clamp Connector User Manual
N041070-10, Class V Torque Tool and Calibration Unit User Manual
N042049-0001, Make-up Bolting Torque Procedure
N113038-45002, VCCS Downfacing Assembly, Back Seal Test Arrangement
Digitally signed by matthew.lean@bhge.com
Authored By: Matthew Lean Signature: Reason: I am the author of this document
Date: 2019.06.10 12:55:45 +08'00'

1.0 SCOPE

The spare VCCS Downfacing Assembly, S/N: 4500113856-00120-044 has been delivered at an agreed
orientation of 11.25 degree. In order to utilize this spare assembly for well jumper BDC-1A-06 the orientation
of the well jumper pipe does not need to be altered, but the Back Seal Test Tubing must be installed and
Dow Corning 732 sealant applied to all gaps and openings between hub and upfacing structure/lock
segments.

Figure 1: Existing orientation of Spare VCCS Downfacing Assembly

The Back Seal Test Receptacle on VCCS Downfacing Assembly S/N: 4500113856-00120-021 must be
replaced with new Back Seal Test Receptacle, P/N: N100773-02, S/N: 460320369-1-001.

2.0 INSTRUCTION

2.1 Ensure JSA / TRA / etc. is completed and approved prior to commencement of activities.

2.2 Verify the serial number of the Downfacing Assembly is S/N: 4500113856-00120-044.

2.3 Verify the Downfacing Assembly is in the correct orientation as shown in Figure 1.

Rev NC GE-URF-TN-0006 Page 1 of 3


2.4 Apply Dow Corning 732 to all gaps and openings between hub and downfacing structure/lock segments.
Example shown in Image 1.

Image 2: Dow Corning 732 on VCCS Downfacing Structure/Lock Segments

2.5 Install the Back Seal Test Tubing in accordance with drawing N113038-45002. The tubing run will be similar
to that depicted in Figure 2.

Rev NC GE-URF-TN-0006 Page 2 of 3


Figure 2: Typical Back Seal Test Tubing Arrangement

2.6 Identify VCCS Downfacing Assembly S/N: 4500113856-00120-021.

Disconnect Back Seal Test Tubing and remove existing Back Seal Test Receptacle. Install the new Back
Seal Test Receptacle, P/N: N100773-02, S/N: 460320369-1-001, using existing M12 x 30.00mm Socket
Head Cap Screws. Make-up torque IAW N042049-0001.

3.0 ACKNOWLEDGEMENT AND SIGN-OFF

I hereby verify that the VCCS downfacing assembly, S/N: 4500113856-00120-044, has be modified in
accordance with the instructions in this technical note.

BHGE Representative: ____________________________________________ Date: _____________________

COMPANY Representative: ________________________________________ Date: _____________________

Rev NC GE-URF-TN-0006 Page 3 of 3


HOT STAB RECEPTACLE REPLACEMENT
INSTALL BACK SEAL TUBING AND PUT DOW SEAL TO DOWNFACING GAP