Positioners
Electric Actuators
5
5/2 Product overview
Software
Sec. 8 SIMATIC PDM, to parameterize HART and
PROFIBUS-PA devices
Siemens FI 01 · 2003
Electropneumatic positioners / Electric actuators
Product overview
Electropneumatic positioners / Electric actuators
5
SIPOS 5 Flash – electric actuators
Electric rotary actuators SIPOS 5 Flash, Electric rotary actuator SIMATIC PDM,
standard version and Standard version: Tc 10 - 4000 Nm 5/24 function block,
modulating duty for safe COM-SIPOS Flash
Modulating duty: Tc 15 - 2800 Nm 5/26
operation of valves
• Parameter assignments can be set by the
customer
• tripping torque and speed settable within
type-specific ranges
• binary and analog inputs and outputs
dependent on design
• freely assignable signaling outputs
• positioner
• process controller
• reference torque curves for the valve can be
stored and evaluated
• speed setting dependent on travel
• external analog speed input
• PROFIBUS DP with V1 services
As above, but SIPOS 5 Flash, Electric linear actuator SIMATIC PDM,
linear actuators Modulating duty: Fc 5.5 - 152 kN 5/28 function block,
COM-SIPOS Flash
modulating duty • Cut-off force and positioning speed of actuator
settable within type-specific ranges,
• otherwise as above
■ Application
The SIPART PS2 electropneumatic positioner is used to control
the final control element of pneumatic linear or part-turn actua-
tors. The electropneumatic positioner moves the actuator to a
valve position corresponding to the setpoint. Additional function
inputs can be used to block the valve or to set a safety position.
A binary input is present as standard in the basic device for this
purpose.
The SIPART PS2 positioner is characterized by significant
advantages compared to conventional devices, such as:
7 Only one device version for linear and part-turn actuators
7 Simple operation and programming using three keys and a
two-line LCD Fig. 5/1 SIPART PS2 or SIPART PS2 PA electropneumatic positioner
7 Automatic startup function with self-adjustment of zero and
span
7 Manual operation without additional equipment
7 Selectable or freely-programmable characteristics
7 Diagnostic functions for valve or actuator (see page 5/5)
7 Minimum air consumption
7 Selectable setpoint and manipulated variable limiting
7 Programmable "tight shut-off function".
■ Design
The SIPART PS2 positioner is a digital field device with a highly-
integrated microcontroller.
The positioner consists of the following components:
- Casing and cover
- PCB with corresponding electronics with or without commu-
nication via HART
or with electronics for communication according to the
PROFIBUS-PA specification, IEC 1158-2; bus-supplied
device
- Actuator travel detection system
- Terminal housing with screw terminals
- Pneumatic valve manifold with piezoelectric valve precontrol.
Fig. 5/3 SIPART PS2 or SIPART PS2 PA in stainless steel casing
The valve manifold is located in the housing, the pneumatic con-
nections for the inlet air and the positioning pressure on the
right-hand side. A pressure gauge block and/or a safety sole-
noid valve can be connected there as options. The circuit board
container in the casing provides slots for separately ordered
boards with the following functions:
7 Iy module:
- Position feedback as a two-wire signal 4 to 20 mA.
7 Alarm module (3 outputs, 1 input):
- Signalling of two limits of the travel or angle by binary signals.
The two limits can be set independently as maximum or min-
imum values.
- Output of an alarm if the setpoint position of the final control
element is not reached in automatic mode or if a device fault
occurs. All signals in the Iy and alarm modules as well as the SIA module
- Second binary input for alarm signals of for triggering safety (see page 5/4) are electrically isolated from one another and
reactions or for blocking/signalling function or safety position. from the basic unit. The outputs indicate self-signalling faults.
Fig. 5/4 Non-contacting position sensor (NCS) for linear actuator (left) and part-turn actuator (right)
Stainless steel casing for extreme ambient conditions Non-contacting position sensor (NCS)
The SIPART PS2 (including the EEx d version) is available in a The actuator travel detection unit can also consist of a non-con-
stainless steel casing (see Fig. 5/3) for use in particularly tacting position sensor instead of a potentiometer. All coupling
aggressive environments (e.g. offshore operation, chlorine elements are omitted such as coupling wheel and driver pin with
5 plants etc.). The device functions are the same as with the basic
device.
part-turn actuators or lever and pick-up bracket with linear actu-
ators.
Limit signalling via slot-type initiators (SIA module) This results in:
Two limits can be signalled redundantly as NAMUR signals • Even greater resistance to vibration and shock
(DIN 19 234) by slot-type initiators using an easy-to-fit module. • No wear of sensor
The module additionally contains an alarm output (see alarm • Problem-free mounting on very small actuators
module).
• No hysteresis with very small travels.
Separate connection of actuator travel detection system and
controller unit The sensor does not require an additional power supply, i.e.
SIPART PS2 can be operated in a two-wire system. The NCS
The actuator travel detection system and controller unit can be (Non-Contacting Position Sensor) consists of a potted sensor
connected separately for all casing versions of the SIPART PS2. housing which must be mounted permanently and a magnet
Measurement of the travel or angle is carried out as usual which is mounted on the spindle of linear actuators or on the
directly on the actuator by means of the corresponding attach- shaft butt of part-turn actuators.
ment set and e.g. a SIPART PS2 casing which contains the travel
detection system (internal potentiometer and sliding clutch). The The installation of a special EMC filter module is necessary in the
controller unit can then be fitted a certain distance away, e.g. on positioner (controller unit) to guarantee EMC according to
a mounting pipe or similar, and is connected to the travel detec- EN 50 081-1 or EN 50 082-2 when using external sensors (see
tion system via an electric cable and to the actuator via one or Ordering data: EMC filter module).
two pneumatic lines (see Fig. 5/5). Such a split design is fre-
quently advantageous if the ambient conditions at the fitting
exceed the specified values for the positioner, e.g.:
• Extremely high/low ambient temperature
• Extremely high vibrations
• Nuclear (e.g. neutron) radiation.
The use of linear potentiometers (10 kΩ resistance) is recom-
mendable for very small actuators with a short valve travel since,
on the one hand, the space required by the linear potentiometer
is very small and, on the other, the transmission characteristic is
optimum for a small travel.
1
HART
2 3
Inlet air
BE1 _ y
3V
pZ
_ + y
+
I W+
Exhaust
+24 V
+5 V p1
p1
W A
D p2
Micro-
I W- controller
p2
A
y D
0 +U
Exhaust
_
+
W
4
x x
0 U
U
I
6
5
BE2 A1 A2
5 I I
8 9
7 p2
A1 A2 p1 p1
Travel
Travel
1 Motherboard with microcontroller and input circuit 7 SIA module (slot initiator alarm module)
2 Control panel with LCD and pushbuttons 8 Spring loaded pneumatic actuator (single-action)
3 Piezoelectric valve unit, always present 9 Springless pneumatic actuator (double-action)
4 Valve unit, present as accessory in double-action positioner Note:
5 Iy module for SIPART PS2 controller Alarm module (6) and SIA module (7) can only be inserted
6 Alarm module for 3 alarm outputs and one binay input
as alternatives.
+ 6
Two-wire system 4 .. 20 mA _ *) R ³ 250 W if req. 2
7 + I H+
J 3
8 - i y = 4 to
I 4
9 20 mA
BE1 5
10
6
Fig. 5/7 SIPART PS2 electropneumatic positioner, input circuit for 7
IW
6DR50.. and 6DR51.. 8
-
HART PC/Laptop
Electric connection of PROFIBUS-PA devices (6DR4105) modem
9 +3 V
10 BE1 Two-wire system
+
6 Three-/Four-wire system
PROFIBUS-PA connection PROFIBUS-PA
7
-
+ 2
9 +3 V 18 .. 30 V 3
10 _ 4
BE1
*) 5
*) Input for safety shutdown (activated using coding jumper)
+ 6
Fig. 5/9 SIPART PS2 PA electropneumatic positioner, input circuit for 0/4 .. 7
6DR55.. 20 mA _
J 8
9
BE1
10
■ SIMATIC PDM
Task Parameterization, startup and
diagnosis of process devices
using PROFIBUS-DP, PROFIBUS-
PA and HART interfaces
Required computer hardware Personal computer/programming
device with Pentium processor
and 32 Mbyte RAM (64 Mbyte or
more recommended)
Operating system Windows 95, Windows NT
With integration in STEP 7 STEP 7, matching the SIMATIC
PDM version
Memory requirements with Approx. 10 Mbyte,
SIMATIC PDM plus 70 Mbyte for
SIMATIC PDM without option
"Integration in STEP 7"
PROFIBUS-DP connection Built-in MPI interface
• For PG 720/740/760 Communications processor
programming device CP 5511 6GK1 551-1AA00
• For personal computer CP 5611 6GK1 561-1AA00
Required drivers are included in
delivery of SIMATIC PDM and in
STEP 7
Transition from PROFIBUS-DP DP/PA coupler, Ex version:
to PROFIBUS-PA 6ES7157-0AD00-0XA0,
DP/PA coupler, non-Ex version:
6ES7157-0AC00-0XA0,
DP/PA link:
6ES7157-0AA00-0XA0
5 Transition from PROFIBUS-DP
to HART
IM 153-2 interface module
6ES7153-2AA01-0XB0,
HART analog input module
6ES7331-7TB00-0AB0
HART point-to-point connection Via HART modem
7MF4997-1DA Fig. 5/13 SIMATIC PDM, parameter table
■ Configuring
The following settings can be configured in configuring mode as
required, e.g. with SIPART PS2:
• Input current range 0 to 20 mA or 4 to 20 mA
• Rising or falling characteristic at the setpoint input
• Positioning speed limit (setpoint ramp)
• Split-range operation; adjustable start-of-scale and full-scale
values
• Response threshold (dead zone); self-adjusting or fixed
• Direction of action; rising or falling output pressure with rising
setpoint
• Limits (start-of-scale and full-scale values) of positioning range
• Limits (alarms) of the final control element position; minimum
and maximum values
Fig. 5/12 SIMATIC PDM, measured-value display • Automatic "tight shut-off" (with adjustable response threshold
for 6DR5...)
• The travel can be corrected in accordance with the valve char-
acteristic. The following can be selected:
- Linear characteristic
- Equal-percentage characteristic 1: 25, 1: 33 and 1: 50
- Inverse equal-percentage characteristic 1: 25, 1: 33 and
1: 50
- Any characteristic, to be entered as a polygon with
21 interpolation points.
• Function of binary inputs
• Function of alarm output.
The SIPART PS2 and SIPART PS2 PA positioners are configured
differently.
■ SIPART PS2 PA configurations (PROFIBUS version) Parameter- Function Parameter values Dimen-
name sion
Parameter- Function Parameter values Dimen-
39. BIN2 4) Function of binary input 2
name sion
1. YFCT Type of actuator: None OFF
part-turn/linear NO
- Part-turn actuator turn Only signal on
- Linear actuator WAY Drive valve to ye uP
- Linear actuator without Drive valve to ya doWn
sine-wave correction LWAY Block movement StoP
- Part-turn actuator with NC
NCS ncST Only signal -on
- Part-turn actuator with Drive valve to ye -uP
NCS, reverse direction -ncST Drive valve to ya -doWn
- Linear actuator with NCS ncSL Block movement -StoP
2. YAGL 1) Rated angle of feedback 90 ° De- 40. AFCT 5) Alarm function
33 ° grees None oFF
2) min : max: normal Mi:MA
3. YWAY Travel range 5 to 130 mm
- None OFF inverted Mi:MA
- Short lever 33° 5/10/15/20 mm min : min: normal Mi:Mi
- Short lever 90° 25/30/35 inverted Mi:Mi
- Long lever 90° 40/50/60/70/90/ max : max: normal MA:MA
110/130 inverted MA:MA
4. INITA Initialization (automatic no 41. A1 Response threshold for alarm 1 0.0 to 100.0 %
commissioning) ###.# 42. A2 Response threshold for alarm 2 0.0 to 100.0 %
Strt
FINISH 43. FCT 5) Function of alarm output
Fault:
5. INITM Initialization (manual no normal
commissioning) ###.# inverted -
Strt Fault + not Automatic:
FINISH normal nA
5 6. SDIR Setpoint direction rising
Setpoint direction falling
riSE
FALL
inverted
Fault + not Automatic + BI:
normal
- nA
nAb
7. TSI Setpoint ramp OPEN Auto
0 to 400 s inverted - nAb
(+ means logical OR
8. TSD Setpoint ramp CLOSED 0 to 400 s operation)
9. SFCT Setpoint function 44. TIM Monitoring time for setting of Auto
- Linear Lin fault signal "Control devia- 0 to 100 s
- Equal percentage 1-25, 1-33, 1-50 tion"
- Equal percentage, reversed n1-25, n1-33,
n1-50 45. LIM Response threshold of fault Auto
- Freely adjustable FrEE signal "Control deviation" 0.0 to 100.0 %
10. SL0 3) Setpoint interpolation points 46. STRK Limit for travel integral 0 to 1.00E9
. with free characteristic 47. DCHG Limit for change in direction OFF
. 0 %, 5 %, 10 % ... 100 % 0.0 to 100.0 % 1 to 1.00E9
30. SL20 48. ZERO Limit for zero limit monitoring OFF
31. DEBA Controller dead zone Auto 0.0 to 100.0 %
0.1 to 10.0 % 49. OPEN Limit for open limit monitor- OFF
32. YA Start of manipulated variable 0.0 to 100.0 % ing 0.0 to 100.0 %
limit 50. DEBA Limit for dead zone monitor- OFF
33. YE End of manipulated variable 0.0 to 100.0 % ing 0.0 to 10.0 %
limit 51. PRST Preset (factory setting) no
34. YNRM Manipulated variable scaling MPOS Strt
mech. travel/flow FLOW oCAY
35. YCLS "Tight shut-off" with man. var. 52. FSTY Safety setting:
- None no Parameterized safety
- Only up uP: setpoint FSVL
- Only down do Last setpoint FSSP
- Up and down uP do Open exhaust air valve FSAC
36. YCDO Value for "tight shut-off", 0.0 to 100.0 % 53. FSTI Monitoring time for setting of 0 to 100 s
down safety position
37. YCUP Value for "tight shut-off", up 0.0 to 100.0 % 54. FSVL Safety setpoint 0 to 100.0 %
38. BIN1 4) Function of binary input 1 55. STNR Station number 0 to 126
None OFF 56. IDENT Device mode (Ident No.)
NO - Multi-vendor 0
Only signal on - Full functionality 1
Block configuring bLoc1
Block config. and manual bLoc2 1
Drive valve to ye uP ) Parameter only visible with "turn" or "WAY"; if "turn" is selected,
Drive valve to ya doWn 33 ° cannot be set.
2
Block movement StoP ) Parameter not visible if 1. YFCT = "turn", "LWAY" or "-ncST"
has been selected.
NC 3
) Interpolation points only appear if 9.SFCT=FrEE has been selected.
Only signal -on 4
) NC means: action with opened switch or Low level.
Drive valve to ye -uP NO means: action with closed switch or High level.
Drive valve to ya -doWn 5
) Normal means: High level without fault.
Block movement -StoP Inverted means: Low level without fault.
■ Dimensional drawings
50 x 4 x M6 Mounting level of positioner
29,5 29,5
65
95
37
>4 mm
80
9 deep M6
72
4 +0
25
M8, 9 deep
29
,1
4
12
23 All air Mounting plate
58 connections 11,2
182 G 1/4 or 1/4 NPT
50 x 4 x M6
9 deep
29,5
Part-turn actuator
84
27,5 29
65
59
34,5
35
M8, 9 deep
23 All air
58 connections 11,2
182 G 1/4 or 1/4 NPT
M20 x 1,5
13,5
8
96,6
h9
6,
5
1
15
7 14,5
88,5
38,5
F05-Lkr.- 50
5
Fig. 5/16 Mounting onto part-turn actuators; mounting plate (scope of de-
livery of actuator manufacturer), extract from VDI/VDE 3845, dimensions
Fig. 5/14 Dimensions (top: plastic casing, center: metal casing,
bottom: plastic casing and metal casing)
1
) When commissioning at ≤ 0 °C make sure that the valves are purged
with the dry medium for a sufficiently long time.
2
) Limited refresh rate of LCD below -10 °C. Only T4 permissible when
using with Iy module.
3
) With the EEx d version (6DR5 7 7 5-...), the values are reduced by
approx. 20%.
■ Technical data
SIPART PS2 Basic device Basic device Basic device Basic device
without Ex protection with Ex protection with Ex protection with Ex protection
EEx d (flameproof cas- EEx ia/ib EEx n
ing)
Explosion protection to Without EEx d EEx ia/ib EEx n
EN 50 014, EN 50 020 and EN 50 021 II 2 G EEx ia/ib II C T6 II 2 G EEx ia/ib II C T6 II 3 G EEx nA L [L] II C T6
Mounting location Zone 1 Zone 1 Zone 2
Permissible ambient temperature for oper- -30 to +80 °C T4:-30 to +80 °C 1) T4:-30 to +80 °C 1) T4:-30 to +80 °C 1)
ation T5:-30 to +65 °C 1) T5:-30 to +65 °C 1) T5:-30 to +65 °C 1)
T6:-30 to +50 °C 1) T6:-30 to +50 °C 1) T6:-30 to +50 °C 1)
Electrical data
Input
Two-wire system (terminals 6/8)
• Rated signal range 4 to 20 mA
• Current to maintain power supply ≥ 3.6 mA
• Required load voltage UB (r Ω at 20 mA)
- without HART 6DR50.. typ. ≤ 6.36 V (r 318 Ω) ≤ 7.8 V (r 390 Ω) ≤ 7.8 V (r 390 Ω)
max. ≤ 6.48 V (r 324 Ω) ≤ 8.3 V (r 415 Ω) ≤ 8.3 V (r 415 Ω)
- without HART 6DR53.. typ. ≤ 7.9 V (r 395 Ω) – – –
max. ≤ 8.4 V (r 420 Ω) – – –
- with HART 6DR51.. typ. ≤ 6.6 V (r 330 Ω) – –
max. ≤ 6.72 V (r 336 Ω) – –
- with HART 6DR52.. typ. – ≤ 8.4 V (r 420 Ω) ≤ 8.4 V (r 420 Ω) ≤ 8.4 V (r 420 Ω)
max. – ≤ 8.8 V (r 440 Ω) ≤ 8.8 V (r 440 Ω) ≤ 8.8 V (r 440 Ω)
• Static destruction limit ± 40 mA – –
• Internal capacitance Ci
- without HART – ≤ 22 nF –
5
- with HART – ≤ 7 nF –
• Internal inductance Li
- without HART – ≤ 0.12 mH –
- with HART – ≤ 0.24 mH –
• For connection to circuits with – Intrinsically-safe Ui ≤ 30 V DC
Uo ≤ 30 V DC Ii ≤ 100 mA
Ik ≤ 100 mA
P ≤1W
Three-wire/four-wire system (terminals 2/4
and 6/8)
(only 6DR52.. and 6DR53..)
• Power supply UH 18 to 35 V DC 18 to 30 V DC 18 to 30 V DC
• Current consumption IH (UH - 7.5 V)/2.4 kΩ [mA]
• Internal capacitance Ci – ≤ 22 nF –
• Internal inductance Li – ≤ 0.12 mH –
• For connection to circuits with – Intrinsically-safe Ui ≤ 30 V DC
Uo ≤ 30 V DC Ii ≤ 100 mA
Ik ≤ 100 mA
P≤1W
Current input IW
• Rated signal range 4 to 20 mA
• Load voltage at 20 mA ≤ 0.2 V (r 10 Ω) ≤ 1 V (r 50 Ω) ≤ 1 V (r 50 Ω)
• Internal capacitance Ci – ≤ 22 nF –
• Internal inductance Li – ≤ 0.12 mH –
• For connection to circuits with – Intrinsically-safe Ui ≤ 30 V DC
– Uo ≤ 30 V DC Ii ≤ 100 mA
– Ik ≤ 100 mA
P ≤1W
1
) Limited refresh rate of LCD below -10 °C. Only T4 permissible when using with Iy module.
SIPART PS2 PA
■ Technical data
SIPART PS2 PA Basic device Basic device Basic device Basic device
without Ex protection with Ex protection with Ex protection with Ex protection
EEx d (flameproof cas- EEx ia/ib EEx n
ing)
Explosion protection to Without EEx d EEx ia/ib EEx n
EN 50 014, EN 50 020 and EN 50 021 II 2 G EEx ia/ib II C T6 II 2 G EEx ia/ib II C T6 II 3 G EEx nA L [L] II C T6
Mounting location Zone 1 Zone 1 Zone 2
1 1
Permissible ambient temperature for oper- -30 to +80 °C T4:-30 to +80 °C ) T4:-30 to +80 °C ) T4:-30 to +80 °C 1)
1 1
ation T5:-30 to +65 °C ) T5:-30 to +65 °C ) T5:-30 to +65 °C 1)
T6:-30 to +50 °C 1) T6:-30 to +50 °C 1) T6:-30 to +50 °C 1)
Electrical data
Input
Power supply (terminals 6/7) Via bus
Bus voltage 9 to 32 V 9 to 24 V 9 to 32 V
• Bus connection with FISCO power supply
unit, ia or ib Group IIC or IIB
- Max. supply voltage (Uo) – 17.5 V –
- Max. short-circuit current (Io) – 380 mA –
- Max. power (Po) – 5.32 W –
• Bus connection with barrier,
ia or ib Group IIC or IIB
- Max. supply voltage (Uo) – 24 V –
- Max. short-circuit current (Io) – 200 mA –
- Max. power (Po) – 1.2 W –
1
) Limited refresh rate of LCD below -10 °C. Only T4 permissible when using with Iy module.
■ Technical data
Option modules Without Ex protection With Ex protection
Electrical data
Ex protection to EN 50 014, EN 50 020 and 50 021 – II 2G EEx ia/ib II C T4/T5/T6 1) II 3G EEx nA L [L] II C T6
Mounting location – Zone 1 Zone 2
Permissible ambient temperature for operation -30 to + 80 °C T4:-30 to +80 °C T4:-30 to +80 °C
T5:-30 to +65 °C T5:-30 to +65 °C
T6:-30 to +50 °C T6:-30 to +50 °C
Alarm module 6DR4004-8A (without Ex pro- 6DR4004-6A (with Ex protec- 6DR4004-6A (with Ex protec-
Binary alarm outputs A1, A2 and alarm output tection) tion) tion)
(terminals 41/42, 51/52 and 31/32)
Signal status High (not triggered) Conductive, R = 1 kΩ, +3/-1% ≥ 2.1 mA2) ≥ 2.1 mA2)
Signal status Low3) (triggered) Non-conductive, IR < 60 µA ≤ 1.2 mA2) ≤ 1.2 mA2)
Internal capacitance Ci – ≤ 5.2 nF –
Internal inductance Li – Negligible –
Power supply UH ≤ 35 V – –
Connection to circuits with – Intrinsically-safe switching Ui ≤ 15.5 V DC
amplifier DIN 19 234
Uo ≤ 15.5 V DC
Ik ≤ 25 mA, P ≤ 64 mW
Binary input BI2
• Electrically connected to basic device
(terminals 21/22)
- Signal status 0 Floating contact, open
- Signal status 1 Floating contact, closed
- Contact rating 3 V, 5 µA
• Electrically isolated from basic device
5 (terminals 11/12)
- Signal status 0 ≤ 4.5 V or open
- Signal status 1 ≥ 13 V
- Inherent resistance ≥ 25 kΩ
Static destruction limit ± 35 V – –
Internal inductance and capacitance – Negligible –
Connection to circuits with – Intrinsically-safe Ui ≤ 25.2 V Ui ≤ 25.2 V DC
Electrical isolation The 3 outputs, the input BI2 and the basic device are electrically isolated from each other
Test voltage 840 V DC, 1 s
SIA module 6DR4004-8G (without Ex pro- 6DR4004-6G (with Ex protec- 6DR4004-6G (with Ex protec-
tection) tion) tion)
Limit monitor with slot-type initiators and alarm output Two-wire connection
(terminals 41/42 and 51/52)
Ex protection Without II 2 G EEx ia/ib IIC T6 II 2 G EEx nA L [L] IIC T6
Connection Two-wire system to DIN 19 234 (NAMUR), for series-connected switching amplifiers
2 slot-type initiators Type SJ2-SN
Function Opener (NC, normally closed)
Connection to circuits with Rated voltage 8 V Intrinsically-safe switching Ui ≤ 15.5 V DC
Current consumption: amplifier DIN 19 234 Pi ≤ 64 mW
≥ 3 mA (limit not triggered) Ui ≤ 15.5 V DC
≤ 1 mA (limit triggered) Ii ≤ 25 mA, Pi ≤ 64 mW
Internal capacitance – ≤ 41 nF –
Internal inductance – ≤ 100 µH –
Electrical isolation The 3 outputs are electrically isolated from the basic device
Test voltage 840 V DC, 1 s
Alarm output (terminals 31/32) See alarm module
1
) Only in conjunction with the basic device 6DR5 7 7 7 - 7 E 7 7 7. Only T4 permissible when using with Iy module.
2
) Switching thresholds with supply to DIN 19 234: UH = 8.2 V, Ri = 1 kΩ.
3
) Low is also the state if the basic device is faulty or without an electrical power supply.
1
) Only in conjunction with the basic device 6DR5 7 7 7 - 7 E 7 7 7. Only T4 permissible when using with Iy module.
1
) FM and CSA approval available soon for 6DR55..
} Available ex stock.
1
) U.S. certification by FM institute.
2
) With a yoke dimension H5 = 95 mm, only the SIPART PS2 in metal
casing can be used.
3
) -1MN or -2MN with NPT thread.
4
) Only together with 6DR4004-8S and 6DR4004-1M.
Fig. 5/17 Mounting of SIPART PS2 (PA) on linear actuators Fig. 5/18 Mounting of SIPART PS2 (PA) on part-turn actuators
■ Ordering data Scope of delivery for mounting kit 6DR4004-8D (for part-turn
actuators)
Scope of delivery for positioner 1 Coupling wheel
Scope of delivery includes: 1 Driver pin
1 SIPART PS2 positioner as ordered 8 Scales
1 Operating Instructions (German/English) according to 1 Pointer
device type
Various screws and lock washers
1 each SIPART PS2 Configuring Instructions - a concise over-
view in German and English Caution:
Scope of delivery for mounting kit 6DR4004-8V (for linear The mounting consoles and the screws for mounting onto the
actuators) part-turn actuator are not included in the scope of delivery and
must be provided by the customer (see Technical data).
1 Mounting bracket
Available ex stock
2 Mounting prisms
Items marked } are available ex stock.
1 U-bracket
Training
1 Lever arm with adjustable pick-up roll
Refer to Catalog ITC for details of training courses for these
2 U-bolts devices.
Various screws and lock washers
Special designs on request
Fig. 5/19 Mounting of SIPART PS2 EEx d (PA) on linear actuators Fig. 5/20 Mounting of SIPART PS2 EEx d (PA) on part-turn actuators
■ Outstanding features
SIPOS 5 Flash actuators are outstanding for the high quality of
their electronics unit and the ruggedness of their mechanical
components:
7 IP 67 degree of protection (IP 68 on request).
7 Constant efficiency over the complete lifecycle.
7 Little maintenance required (inspection recommended after
8 years).
7 Non-wearing asynchronous motor.
7 Soft starting in the end positions and soft approach to the end
positions.
7 Housing material: corrosion-resistant aluminum alloy with
stainless steel bolts on the outside.
7 Separate mounting of electronics unit and gear unit by loos-
ening a flange connection (4 bolts).
7 Tripping torques (or cut-off forces) and speeds (or positioning
Fig. 5/21 SIPOS 5 Flash, electric actuator (rotary actuator) time /positioning speeds) are freely selectable within a defi-
ned range without altering the hardware.
■ Applications 7 Operator prompting with PROFITRON in plain text and 5
languages (expandable).
SIPOS 5 Flash electric actuators are used primarily in process
plants for safe and precise control of valves (ordinary valves, 7 Three valve reference torque curves with 1% steps can be
gate valves, dampers, vanes and cocks). stored and evaluated in the actuator electronics (optional).
7 Speed setting can be programmed according to valve posi-
SIPOS 5 Flash actuators are equally well-suited for use in power
plants, in chemical and petrochemical plants and in the water- / tion using 10 interpolation points (optional).
wastewater treatment whenever the aim is to replace conven- 7 External analog speed input via 0/4-20 mA (optional).
5 tional control technology, such as reversing contactor or thyris-
tor-type controllers and switching cabinets, with decentralized
7 Functional enhancements made available over the internet
in the form of firmware updates. They can be activated if re-
controls integrated in the actuator. quired.
7 Firmware can be updated without replacing the hardware
■ Principle of operation (Flash EEPROM).
Three-phase current for the asynchronous motor is generated by 7 Reduced spare parts stock due to interchangeable compo-
means of the power circuit module in the electronic, regardless nents.
of the power supply (1-phase or 3-phase). Frequency converters
and microcontrollers allow different speeds and precise tripping
torques to be set (no overtorque).
■ Electrical connection/electronic circuits
7 Frequency range: 47 - 63 Hz
The phase angle is checked and automatically adjusted, so that 7 1-phase power supply 230 V (±15%)
the direction of rotation is always correct.
7 3-phase power supply range: 400 - 460 V (±15%)
The compact design of the electronics, in which the control
module and the power circuit module are tuned to one another 7 Other power supplies possible in conjunction with matching
exactly, permits the actuator to be soft-started - something that transformers (optional)
helps prolong the life-time of the valve. Thanks to the integrated 7 Solid-state full motor protection and automatic phase se-
electronics, the starting current is not higher than the rated cur- quence correction
rent, so that connecting cables with a smaller cross-section can 7 Additional external 24 V DC supply possible
be used compared to conventional actuators.
7 Customized assignment of signaling outputs
The gearbox used is a sturdy, proven worm shaft/worm wheel 7 Position actual value: 0/4-20 mA (depending on design)
assembly, which is self-locking up to an output speed of 80 rpm.
7 Internal positioner via analog setpoint input: 0/4-20 mA
The travel is recorded and electronically evaluated by means of (optional)
a precision potentiometer. 7 Internal process controller via analog setpoint input:
The integrated electronics is responsible for measuring the 0/4-20 mA (optional)
torque and for cut-off when the tripping torque is reached. The 7 Parameters can be programmed via:
travel-dependent cut-off function is also controlled by this unit.
- Local control unit
During the startup phase or in the event of a power failure, the - PC parameterization software: COM-SIPOS Flash (optional)
actuator can be positioned with the aid of a hand crank handle
or -wheel. - Function blocks for PCS7 (optional)
- SIMATIC PDM
Linear and part-turn movements are achieved by means of a
combination of a rotary actuator and a thrust-unit or worm gear 7 Totally integrated control, monitoring and parameterization for
box. PROFITRON in conjunction with PROFIBUS
. 7 PROFIBUS DP-V1 (optional)
(acyclic services)
the minimum value is set as standard (30% Mdmax) 1) [kg] see next page
10 - 30 19.5 1
20 -60 20.5 2
40 - 125 33 3
80 - 250 39 4
160 - 500 64 5
350 - 1000 70 6
700 - 2000 149 7
1400-4000 155 8
1
) Other torque settings - see additional features „Y01“.
2
) The acme screw thread must be expressly stated, e.g. Tr 16x4 LH DIN 103.
3
) The special bore must be stated, e.g. ∅26 with featherkey A8x7 DIN 6885.
2SA50 7 7 - 7 7 7 7 7 - 7 7 7 7 - Z 777
speed- output speed, adjustable [rpm] set
range for the torque ranges [Nm] at 1) see
previous
1.25 - 10 non selflocking 1400-4000 3.5 page A
2.5 - 20 700-2000 1400-4000 7 B
5 - 28 700-2000 14 C
5 - 40 10-30 20-60 40-125 80-250 160-500 350-1000
10 - 80 10-30 20-60 40-125 80-250 160-500 350-1000 28 D
20 - 112 10-30 160-500 56 E
20 - 160 20-60 40-125 80-250
3x 10-30 20-60 E
AC 400 - 460 V 40-125
80-250 160-500 350-1000 700-2000 1400-4000
electric connection
direct connection with round hood (with plugs to the printed 3
circuit board)
round plug with screw connection 4
1
) Other settings of the output speed - see additional features „Y07“.
2
) Connection to other power supply via adaption transformer 2SX5000-... on request.
3
) Only in combination with round plug (see Electric connection, data position „16“) possible.
electric connection
direct connection with round hood (with plugs to the 3
printed circuit board)
round plug with screw connection 4
1
) Other settings of the output speed - see additional features „Y07“.
2
) Connection to other power supply via adaption transformer 2SX5000-... on request.
3
) Only in combination with round plug (see Electric connection, data position „16“) possible
flange size
DIN 3358 for the cut-off force ranges [kN]
F07 5.5-7.7 11-15.4 0
F10 5.5-7.7 11-15.4 17.5-25 1
F14 31.5-45 62.5-90 3
F16 106-152 4
driving rod stroke [mm]
(without yoke) for the cut-off force ranges [kN] 2)
thread thread 5.5 - 11 - 17.5 - 31.5 - 62.5 - 106 - pitch more
length 7.7 15.4 25 45 90 152
[mm]
[mm] weight [kg]
M12 x 1.25 25 50 5 -
M16 x 1.5 25 50 5 -
M20 x 1.5 30 63 6 -
M36 x 3 55 80 80 7 -
M42 x 3 65 100 8 - 0
M12 x 1.25 25 100 5 1
M16 x 1.5 25 100 5 1
M20 x 1.5 30 125 6 2
M36 x 3 55 160 160 7 3
M42 x 3 65 200 8 5 1
M12 x 1.25 25 200 5 2
M16 x 1.5 25 200 5 2
M20 x 1.5 30 250 6 5
M36 x 3 55 320 320 7 9
M42 x 3 65 400 8 17 2
M12 x 1.25 25 400 5 5
M16 x 1.5 25 400 5 5
M20 x 1.5 30 400 6 8
M36 x 3 55 400 400 7 12 9 H0B
1
) For other cut-off force settings - see additional features „Y03“.
2) For travel distance setting - see table and additional features „Y04“.
electric connection
direct connection with round hood (with plugs to the printed 3
circuit board)
round plug with screw connection 4
1
) For other travel distance setting - see additional features „Y04“.
2
) Other settings of the positioning speed - see additional features „Y08“.
3
) Connection to other power supply via adaption transformer 2SX5000-... on request.
4
) Only in combination with round plug (see Electric connection, data position „16“) possible.
electric connection
direct connection with round hood (with plugs to the 3
printed circuit board)
round plug with screw connection 4
electric connection
direct connection with round hood (with plugs to the printed 3
circuit board)
round plug with screw connection 4
1
) For other positioning time setting - see additional features „Y09“.
2
) Connection to other power supply via adaption transformer 2SX5000-... on request.
3) Or other mounting arrangements - see additional features „S50“, „S51“ and „S52“.
4
) Freely rotating gear, i.e. without end stop.
5
) Only in combination with round plug (see Electric connection, data position „16“) possible.
other settings/programming
Please specify in plain text or use the
enclosed programming sheet Y11
Parameter assignment acc. to Siemens
PG standard for FUM block Y12
Parameter assignment acc. to Siemens
PG standard for SIM block Y15