 Constant Spring Hangers with Huge displacement & #62269 ­ 03/03/15 02:00 AM
lower loads Go
Piyushno1  Advanced
 
Member  Hi Frens, 
      Who's Online
 
Registered:
10/13/10  We are working on a 3" & 6" reactor lines connected at the topmost 1 registered (Faizal K),
Posts: 7    section of reactor that is almost at 100 meters height from the grade 32 Guests and 1
Loc: Malaysia level. The lines needs constant support hangers at almost all locations Spider online.
on the platform (control station), so as to absorb the huge differential Key: Admin, Global Mod,
displacement between reactor & support structure. Note, there is an Mod
independent structure for the reactor & platform & it is no where
connected to reactor. Hence, differential displacements. March
 
The vertical displacement at constant spring supports is around +575 to Su M Tu W Th F Sa
+595 mm (vertically up) and operating loads is in the range of 2KN to
3.5KN maximum. We checked with almost all the spring vendors, no 1 2
constant spring is available with this displacements values for the given 3 4 5 6 7 8 9
loads (very less loads). Vendors suggest that we need higher loads 10 11 12 13 14 15 16
atleast in range of 10 ­ 20KN for which they can design the spring for
17 18 19 20 21 22 23
the given thermal displacements.
 
Can you please guide me the alternate supporting arrangement, where 24 25 26 27 28 29 30
we can allow the thermal displacement upto 600mm & where loads at 31
support location can be upto 3.5 ­ 5 KN range.
    Forum Stats
I have attached the Caesar II file (ver 2013 R1)& also the snapshot of
11627 Members
the piping arrangement so as to have the better understanding of the  
14 Forums
problem.  
  15775 Topics
 
70864 Posts  
Request you to provide an alternate solution (support type/supporting  
 
arrangement)for the constant springs.  Max Online: 126 @
    05/09/18 04:29 PM
One option which I came across is the counterweight balance
arrangement mostly used in radiation & crossover section of SRT
heaters. However, I dont have any idea on it. Incase, anyone has any
idea, please share.
   
Thanks in advance for the time & efforts spent on the above.
 
 
Attachments 
 

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=62284&Searchpage=4&Main=14259&Words=constant&Search=true#Post62284 1/4
13/03/2019 Constant Spring Hangers with Huge displacement & lower loads - Intergraph CADWorx & Analysis

   

   
CN­043­002_A.C2 (81 downloads)
   
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Constant Spring Hangers with Huge displacement #62270 ­ 03/03/15 03:32 AM
& lower loads [Re: Piyushno1]
adi singh   
Member    Kindly check the temperature distribution of Reactor.
     
You can distribute the temperature profile to take the real effect.
Registered:  
12/10/07  so Upward thermal movement will be more realistic.
Posts: 67    
Loc: india
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Constant Spring Hangers with Huge displacement #62282 ­ 03/04/15 12:03 AM
& lower loads [Re: adi singh]
Piyushno1 
Member  Hi Adi, 
     
 
Registered:
10/13/10  Already checked & confirmed with mechanical as well process, entire
Posts: 7    reactor's operating temp is at 549ºC. The reactor is Continuous
Loc: Malaysia Catalytic Regeneration (CCR) Reactor.
 
As far as process input are concerned, we were unsuccessful in all our
attempts to get some relief on temp. 
 
For same process input, we qualified all big bore lines mainly 42" dia
using constant springs, for which spring vendor customised few of those
springs so as to accomodate loads/displacements/space requirements.
However, as per vendor there are no such springs available/can be
customised for huge displacements upto 595mm with constant loads of
2KN. Hence, looking for an alternate to constant spring support.
 
There is an alternate support namely counterweight support ­ basically a
http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=62284&Searchpage=4&Main=14259&Words=constant&Search=true#Post62284 2/4
13/03/2019 Constant Spring Hangers with Huge displacement & lower loads - Intergraph CADWorx & Analysis
rope & pulley arrangement that has counter wieght on one side so as to
support the pipe on other side, which shall allow the pipe thermal
movement with constant load throughout the operating conditions.
However, I have never used it & hence don't know its reliability of
operation for such critical lines at high temperatures & that too at higher
elevations. Experts please share your experience/opinion on the above
case. 
   
Thanks.
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Constant Spring Hangers with Huge displacement #62283 ­ 03/04/15 01:21 AM
& lower loads [Re: Piyushno1]
MAHESH3091990
  Dear Piyush,
 
Member     
   
As you have said that you have qualified big bore lines connected to
Registered: 06/04/14 
Posts: 11    same equipment using high load , high displacement consatnt
Loc: MAHARASHTRA springs . 
   
I have not came across situation that you are facing .
   
As an option , is it possible to support two or more lines on one
constant spring by making special arrangement of pipe shoe .
   
Try it , if it works .
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Constant Spring Hangers with Huge displacement #62284 ­ 03/04/15 01:48 AM
& lower loads [Re: MAHESH3091990]
Piyushno1 
Member  Thanks Mahesh,
     
Your suggestion is good. However, not all lines are running together or
Registered:
10/13/10  parallel that can be combined. Also, re­routing the lines also is not a
Posts: 7    solution, as there are specific process requirements mentioned on P&IDs
Loc: Malaysia for the max distance (3 mtrs) between the reduction gas heaters
(mounted on topmost part of reactor ­ 3nos) & the nozzles on Reactor
top. However, in my calculation, i have exceeded their max requirement
by 1 mtr, which can be tackled seperately.
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Search Results
 
Tweet

Like Be the first of your friends to like this.

 
Quick Reply:
HTML is
enabled
UBBCode  
is
enabled 
 Add  
Signature

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=62284&Searchpage=4&Main=14259&Words=constant&Search=true#Post62284 3/4
13/03/2019 Constant Spring Hangers with Huge displacement & lower loads - Intergraph CADWorx & Analysis
 
Submit   Preview Reply   Switch to Full Reply Screen
 
Moderator:  Dave Diehl, Richard Ay  Hop to:     CAESAR II   Go
Privacy statement · Board Rules · Mark all read
GooG_v2_copy_copy_copy Contact Us · Home Page · Top

 
Generated in 0.040 seconds in which 0.024 seconds were spent on a total of 14 queries. Zlib compression disabled.
Powered by UBB.threads™ 7.5.7  

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=62284&Searchpage=4&Main=14259&Words=constant&Search=true#Post62284 4/4

Você também pode gostar