KV650C2

Engine type TAD1642GE


Alternator type KH02880T
Performance class G3

GENERAL CHARACTERISTICS
Frequency (Hz) 50
Voltage (V) 400/230
Standard control panel APM403
Optional control panel APM802
Optional control panel M80
Optional control panel DEC4000

POWER
ESP PRP
Voltage Standby Amps
kWe kVA kWe kVA

415/240 520 650 473 591 904


DESCRIPTIVE
400/230 520 650 473 591 938
Kohler Co. Provides one-source responsibility for the
generating system and accessories 380/220 520 650 473 591 988
The generator set and its components are prototype- 240 TRI 520 650 473 591 1564
tested, factory-built, and production-tested 230 TRI 520 650 473 591 1632
A one-year limited warranty covers all systems and
components
220 TRI 520 650 473 591 1706
Electronic governor
Mechanically welded chassis with antivibration DIMENSIONS COMPACT VERSION
suspension Length (mm) 3470
Main line circuit breaker
Width (mm) 1630
Radiator for core temperature of 48/50°C max with
mechanical fan Height (mm) 2095
Protective grille for fan and rotating parts (CE option) Dry weight (kg) 3780
9 dB(A) silencer supplied separately Tank capacity (L) 610
Charger DC starting battery with electrolyte
24 V charge alternator and starter
DIMENSIONS SOUNDPROOFED VERSION
Delivered with oil and coolant -30°C
Commercial reference of the enclosure M230
Manual for use and installation
Length (mm) 5031
POWER DEFINITION Width (mm) 1690
PRP : Prime Power is available for an unlimited number of annual
operating hours in variable load applications, in accordance with ISO Height (mm) 2672
8528-1. ESP : The standby power rating is applicable for supplying Dry weight (kg)
emergency power in variable load applications in accordance with ISO
5300
8528-1. Overload is not allowed Tank capacity (L) 610
TERMS OF USE Acoustic pressure level @1m in dB(A) 80
According to the standard, the nominal power assigned by the genset is
given for 25°C Air Intlet Temperature, of a barometric pressure of 100 Sound power level guaranteed (Lwa) 100
kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions Acoustic pressure level @7m in dB(A) 70
in your installation, refer to the derating table.
ASSOCIATED UNCERTAINTY
For the generator sets used indoor, where the acoustic pressure levels
depend on the installation conditions, it is not possible to specify the
ambient noise level in the operating and maintenance instructions.
You will also find in our operating and maintenance instructions a
warning concerning the air noise dangers and the need to implement
appropriate preventive measures.

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-06007 (KV650C2) 06/17
KV650C2
ENGINE CHARACTERISTICS

GENERAL ENGINE DATA EXHAUST


Engine model VOLVO Exhaust gas temperature @ ESP 50Hz (°C) 482
Engine type TAD1642GE Exhaust gas flow @ ESP 50Hz (L/s) 1708
Air inlet Turbo Max. exhaust back pressure (mm H2O) 1000
Cylinders arrangement L
Number of cylinders 6
FUEL
Displacement (L) 16.12
Consumption @ 110% load (L/h) 132.9
Charge Air coolant Air/Air DC
Consumption @ 100% load (L/h) 119.6
Bore (mm) x Stroke (mm) 144 x 165
Compression ratio Consumption @ 75% load (L/h) 88.4
16.5 : 1
1500 Consumption @ 50% load (L/h) 58.9
Speed (RPM)
Pistons speed (m/s) 8.25 Maximum fuel pump flow (L/h) 180
Maximum stand-by power at rated
565
RPM (kW) OIL
Frequency regulation, steady state (%) +/- 0.5% Oil capacity (L) 48
BMEP (bar) 25.5 Min. oil pressure (bar) 0.7
Governor type Electronic Max. oil pressure (bar) 6.5
Oil consumption 100% load (L/h) 0.7
COOLING SYSTEM Oil sump capacity (L) 42
Radiator & Engine capacity (L) 60
Max water temperature (°C) - HEAT BALANCE
Outlet water temperature (°C) - Heat rejection to exhaust (kW) 427
Fan power (kW) 11 Radiated heat to ambient (kW) 20
Fan air flow w/o restriction (m3/s) 10 Heat rejection to coolant (kW) 218
Available restriction on air flow (mm
30
H2O)
Type of coolant Glycol-Ethylene AIR INTAKE
Thermostat modulating range HT (°C) - Max. intake restriction (mm H2O) 500
Intake air flow (L/s) 676
EMISSIONS
Emission PM (g/kWh) 0.11
Emission CO (g/kWh) 0.67
Emission HC+NOx (g/kWh) 5.67
Emission HC (mg/Nm3) 5% O2 -

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-06007 (KV650C2) 06/17
KV650C2
ALTERNATOR CHARACTERISTICS

GENERAL DATA OTHER DATA


Alternator type KH02880T Continuous Nominal Rating 40°C (kVA) 600
Number of Phase Three phase Standby Rating 27°C (kVA) 660
Power factor (Cos Phi) 0.8 Efficiencies 100% of load (%) 94.5
Altitude (m) 0 to 1000 Air flow (m3/s) 0.9
Overspeed (rpm) 2250 Short circuit ratio (Kcc) 0.365
Number of pole 4 Direct axis synchro reactance unsaturated (Xd) (%) 330
Capacity for maintaining short circuit at Quadrature-axis synchro reactance unsaturated (Xq)
No 168
3 ln for 10 s (%)
Insulation class H Open circuit time constant (T'do) (ms) 1997
T° class (H/125°), continuous 40°C H / 125°K Direct axis transient reactance saturated (X'd) (%) 16.5
T° class, standby 27°C H / 163°K Short circuit transient time constant (T'd) (ms) 100
AVR Regulation Yes Direct axis subtransient reactance saturated (X''d) (%) 11.5
Total Harmonic Distortion in no-load Subtransient time constant (T"d) (ms) 10
<2
DHT (%) Quadrature-axis subtransient reactance saturated
Total Harmonic Distortion, on load DHT (X"q) (%) 15.2
<2
(%) Subtransient time constant (T"q) (ms) 10
Wave form : NEMA=TIF <50 Zero sequence reactance unsaturated (Xo) (%) 0.6
Wave form : CEI=FHT <2 Negative sequence reactance saturated (X2) (%) 13.43
Number of bearing 1 Armature time constant (Ta) (ms) 15
Coupling Direct No load excitation current (io) (A) 0.92
Voltage regulation at established rating 0.5
(+/- %) Full load excitation current (ic) (A) 3.65
Recovery time (Delta U = 20% 500 Full load excitation voltage (uc) (V) 62.1
transient) (ms) Engine start (Delta U = 20% perm. or 50% trans.)
Protection class IP 23 1144.84
(kVA)
Technology Without collar or Transient dip (4/4 load) - PF : 0,8 AR (%) 15
brush
No load losses (W) 6794.24
Heat rejection (W) 27572.3
Unbalanced load acceptance ratio (%) 70

DIMENSIONS
Dimensions soundproofed version Dimensions DW compact version
Commercial reference of the enclosure M230 Commercial reference of the enclosure -
Length (mm) 5031 Length (mm) 5083
Width (mm) 1690 Width (mm) 1960
Height (mm) 2672 Height (mm) 2355
Dry weight (kg) 5300 Dry weight (kg) 4420
Tank capacity (L) 610 Tank capacity (L) 1950
Acoustic pressure level @1m in dB(A) 80 Acoustic pressure level @1m in dB(A) -
Sound power level guaranteed (Lwa) 100 Sound power level guaranteed (Lwa) -
Acoustic pressure level @7m in dB(A) 70 Acoustic pressure level @7m in dB(A) -

Dimensions DW soundproofed version


Commercial reference of the enclosure M230DW
Length (mm) 5083
Width (mm) 1690
Height (mm) 2932
Dry weight (kg) 5910
Tank capacity (L) 1950
Acoustic pressure level @1m in dB(A) 80
Sound power level guaranteed (Lwa) 100
Acoustic pressure level @7m in dB(A) 70

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-06007 (KV650C2) 06/17
KV650C2
CONTROL PANEL

APM403, basic generating set and power plant APM802 dedicated to power plant management
control

The highly versatile DEC4000 control unit is complex The new APM802 command/control system is specifically
yet accessible, thanks to the particular attention paid to designed for operating and monitoring power plants for
optimising its ergonomics and ease of use. With its large markets including hospitals, data centres, banks, the oil and
display screen, buttons and scroll wheel, it places the gas sector, industries, IPP, rental and mining.
accent on simplicity and communication.
The Human Machine Interface, designed in collaboration
The DEC4000 offers the following functions: with a company specialising in interface design, facilitates
operations with a large 100% touch screen. The pre-
Electrical measurements: voltmeter, frequency meter, configured system for power plant applications features a
ammeter. brand new customisation function which complies with the
international standard IEC 61131-3. New communication
Engine parameters: working hours counter, oil pressure, functions (PLC and regulation), improve the high level of
coolant temperature, fuel level, engine speed, battery equipment availability in the installation.
voltage.

Alarms and faults: oil pressure, coolant temperature, failure


to start, overspeed, alternator min./max., battery voltage Advantages:
min./max., emergency stop, fuel level. Dedicated to power plant management.
Specially researched ergonomics.
Ergonomics: wheel for navigating around the various High level of equipment availability.
menus. Modularity and long service life guaranteed.
Making it easy to extend the installation
Communication: remote control and operation software,
USB connections, PC connection. For more information, please refer to the sales
documentation.
For more information on the product and its options, please
refer to the sales documentation.

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-06007 (KV650C2) 06/17
KV650C2
CONTROL PANEL

M80, transfer of information DEC4000, ergonomic and user-friendly

The M80 is a dual-function control unit. It can be used as a The highly versatile DEC4000 control unit is complex
basic terminal block for connecting a control box and as an yet accessible, thanks to the particular attention paid to
instrument panel with a direct read facility, with displays optimising its ergonomics and ease of use. With its large
giving a global view of your generating set's basic display screen, buttons and scroll wheel, it places the
parameters. accent on simplicity and communication.

Offers the following functions: The DEC4000 offers the following functions:

Engine parameters: tachometer, working hours counter, Electrical measurements: voltmeter, frequency meter,
coolant temperature indicator, oil pressure indicator, ammeter.
emergency stop button, customer connection terminal
block, CE. Engine parameters: working hours counter, oil pressure,
coolant temperature, fuel level, engine speed, battery
voltage.

Alarms and faults: oil pressure, coolant temperature, failure


to start, overspeed, alternator min./max., battery voltage
min./max., emergency stop, fuel level.

Ergonomics: wheel for navigating around the various


menus.

Communication: remote control and operation software,


USB connections, PC connection.

For more information on the product and its options, please


refer to the sales documentation.

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-06007 (KV650C2) 06/17

Você também pode gostar