Você está na página 1de 1

BOLT DESCRIPTION

S.NO SIZE LOCATION TOTAL


1 13.5X18Ø SLOT WEB 4

146.3

1382
1432
1462
0
30

2.0
30
1.5t

60
60
30

4NO's-13.5x18Ø SLOT BRACING BR-1


FOR M12 BOLT
BRACING BR-1 60CU30x2.0
VIEW X-X (WEB)

1467.7
1517.7

1547.7
147.8
30
0

2.0
1.5t
30

60
60
30

4NO's-13.5x18Ø SLOT BRACING BR-2


FOR M12 BOLT
BRACING BR-2
VIEW X-X (WEB) 60CU30x2.0

BOLT DESCRIPTION
S.NO SIZE LOCATION TOTAL
1 13.5X18Ø SLOT WEB 4

TOLERANCE:-
1. THE STRAIGHTNESS OF ANY LENGTH SHALL BE SUCH THAT
THE OFFSET DOES NOT EXCEED 1 /600 OF THAT LENGTH, WHEN
MEASURED ALONG BOTH THE X-X AND Y-Y AXIS.
2. THE DEVATION OF THE PROFILE DIMENSIONS SHALL NOT
EXCEED ±0.5 MM. THE DEVIATION FROM THE ANGLE OF 90°
SHALL NOT EXCEED ±1.
SPECIAL NOTES: 3. THE SECTION SHALL BE REASONABLY FREE FROM TWIST.
RENOVATION OF UNCOATED OR DAMAGED AREAS FOR PREGALVANIZED MATERIALS: AREA OF SURFACE THAT ARE UNCOATED/DRILLED/CUTTED EDGES WHEN GALVANIZED SHALL BE RENOVATED BY ZINC SPRAYING (AFTER CLEANING & REMOVAL 4. THE TOLERANCE ON THICKNESS FOR THE STRIP USED SHALL
OF MILL SCALE), BY ZINC RICH PAINT (NORMALLY MIN. 90 PERCENT M/M METALLIC ZINC CONTENT OF DRY FILM) OR BY LOW MELTING ZINC ALLOY BE THE SAME AS THAT SPECIFIED IN IS: 1852-1985.
ISSUED FOR MASS PRODUCTION
PROJECT TITLE :- 1.5 MW SPV PROJECT AT MALLANGINAR,TN
CLIENT EPC CONTRACTOR CONSULTANT
CLIENT :- STATKRAFT SOLAR SOLUTIONS (SKSS)
NOTES:-
EPC CONTRACTOR :-
1. FABRICATION AND ERECTION SHALL BE CARRIED OUT IN
ACCORDANCE WITH LATEST IS 800 AND IS 801. CONSULTANT :- ARBUTUS CONSULTANT PVT LTD 02 21.06.2018 REVISED AS PER COMMENTS SS
2. MATERIAL TOLERANCE SHALL BE AS PER IS 1852.
3. HOT DIP GALVANIZATION SHALL BE CARRIED OUT AS PER DRAWING TITLE :- MMS-FABRICATION DETAILS 01 13.06.2018 REVISED AS PER COMMENTS SS
IS 4759.
DRAWING NO :- SKSS_TN03_2019-001-C-9 00 03.06.2018 FIRST SUBMISSION SS
4. ALL COLD FORM SECTION SHALL BE AS PER IS 811.
5. INTERNAL RADIUS "AT CURVES SHALL GENERALLY BE DRAWN SS SCALE NTS NO. DATE REMARKS DRAWN
TAKEN AS 1.5t. DRAWING ISSUED STATUS :
CHECKED SM SHEET NO 01 FOR INFORMATION FOR
AS-BUILT
APPROVAL ONLY CONSTRUCTION
APPROVED DP PAPER SIZE A3

DATE 21.06.2019 REV NO. 02