Você está na página 1de 43

DESIGN AND FABRICATION OF TEMPERATURE

MEASUREMENT SET UP

A PROJECT REPORT

Submitted by

ARUN KUMAR.S (105914144005)

RAJESH KUMAR.M (105914144039)

RAJSHEKAR.S (105914144040)

SEENIVASAGAN.R (105914144047)

In partial fulfillment for the award of the degree of

BACHELOR OF ENGINEERING

IN
MECHANICAL ENGINEERING

RAJA COLLEGE OF ENGINEERING AND TECHNOLOGY, MADURAI


ANNA UNIVERSITY: CHENNAI 600 025
APRIL 2013
ANNA UNIVERSITY: CHENNAI 600 025

BONAFIDE CERTIFICATE
Certified that this project report "DESIGN AND FABRICATION OF
TEMPERATURE MEASUREMENT SETUP" is the bonafide work of
"ARUN KUMAR.S (105914144005), RAJESH KUMAR.M (105914144039),
RAJSHEKAR.S (105914144040), and SEENIVASAGAN.R (105914144046)"
who carried out the project work under my supervision.

SIGNATURE SIGNATURE

Prof. P.SUGUMARAN M.E., Ph.d T.KATHIRAVAN B.E


HEAD OF THE DEPARTMENT SUPERVISOR
Assistant professor
Mechanical Engineering Mechanical Engineering
Raja College of Engg&Tech, Raja College of Engg &Tech,
Madurai- 625020. Madurai- 625020.

Submitted for the project vice-voce held on ……………

INTERNAL EXAMINER EXTERNAL EXAMINER

2
ACKNOWLEDGEMENT

This project has been successfully completed owing comprehensive endurance of many
distinguished persons.

First and foremost we would like to thank the almighty, our family members , and friends for
encouraging us to do this project.

We extend our heartfelt thanks to our beloved Chairman PDG.Lion. G. Nagarajan , M.A and
our Principal Dr. S.M. Sekkilar, M.E., Ph.D for their advice and ethics inculcated during the
entire period of our study

We are extremely indebted to Prof. P. Sugumaran, B.E. (Distn), M.E., Ph.D, The Head Of
Department of Mechanical Engineering for the devoted attention, love and affection shown on us
in making this project grand success.

We profusely thank our internal guide, Mr. T. Kathiravan, B.E., Asst. professor, Mechanical
Engineering for his support throughout the project. His suggestions and participative
encouragement throughout the project will ever hold a memorable place in our hearts.

Finally, we thank one and all for their valuable support in this project work.

3
ABSTRACT

This can be used for measuring, controlling and acquisition of the temperatures
in the engineering systems. The apparatus is used mainly to observe the source temperature by
sensor and to generate graph between temperature and time by using the program in the
microcontroller. Graphs can be drawn between a temperature and time.

4
TABLE OF CONTENTS

CHAPTER NO TITLE PAGE NO.

ABSTRACT 4

LIST OF TABLES 7

LIST OF FIGURES 8

1. INTRODUCTION 9

1.1 Temperature 10

1.2 Temperature control 10

2. SENSOR 11

2.1 Sensor 12

2.2 Sensor deviation 12

2.3 Resistance thermometer 13

2.4 R Vs T relationship of various metals 13

2.5 Element types 15

2.6 Function 15

2.7 Advantages and limitations 16

2.8 Sources of error 17

5
2.9 RTDs vs thermocouples 17

2.10 Construction 17

2.11 Classifications of RTDs 18

2.12 Applications 18

2.13 History 19

2.14 Pt100 Platinum Resistance Thermometers 19

3. TEMPERATURE READER (CONTROLLER) 23

3.1 Introduction to Temperature Controllers 24

3.2 Different Types of Controllers, and How Do They Work? 24

3.3 SELEC TC303 26

4. PIC16F877A and RS232 29

4.1 PIC16F877A 30

4.2 RS232 31

5. GRAPHICAL DISPLAY 37

5.1 Graphical LCD 128*64 38

5.2 Interfacing of PIC16F877A with 128x64 graphical display 38

6. PROCEDURE 41

6.1 PROCEDURE 42

COST ESTIMATION 42

CONCLUSION 43

6
LIST OF TABLES PAGE NO

TABLE 4.1.1 FEATURES OF PIC16F877A 31

TABLE 4.2.1 SIGNALS IN RS232 33

TABLE 4.2.2 PIN ASSIGNMENTS 34

7
LIST OF FIGURES PAGE NO

FIG 2.10.1 CONSTRUCTION OF RTD 18

FIG 2.14.1 Pt100 SENSOR 20


FIG 3.2.1 STANDARD PANEL SIZES 26

FIG 3.3.1 TEMPERATURE READER (CONTROLLER) 28

FIG 4.1.1 PIC16F877A 31

FIG 4.2.1 RS232 cable 36

FIG 5.1.1 Graphical LCD 128*64 38


FIG5.2.1 Interfacing of PIC16F877A with 128x64 graphical display 40

FIG 6.1 BLOCK DIAGRAM OF TEMPERATURE MEASUREMENT SETUP 42

8
CHAPTER1

INTRODUCTION

9
1.1 Temperature:

Temperature is a physical quantity that is a measure of hotness and coldness on a numerical


scale. It is a measure of the thermal energy per particle of matter or radiation; it is measured by a
thermometer, which may be calibrated in any of various temperature scales: Celsius, Fahrenheit,
Kelvin, etc.

Temperature is an intensive property, which means it is independent of the amount of material


present; in contrast to energy, an extensive property, which is proportional to the amount of
material in the system. For example a spark may well be (very briefly!) as hot as the Sun.

Empirically it is found that an isolated system, one that exchanges no energy or material with its
environment, tends to a spatially uniform temperature as time passes. When a path permeable
only to heat is open between two bodies, energy always transfers spontaneously as heat from a
hotter body to a colder one. The transfer rate depends on the thermal conductivity of the path or
boundary between them. Between two bodies with the same temperature no heat flows. These
bodies are said to be in thermal equilibrium.

In kinetic theory and in statistical mechanics, temperature is the effect of the thermal energy
arising from the motion of microscopic particles such as atoms, molecules and photons. The
relation is proportional as given by the Boltzmann constant.

1.2 Temperature control:

Temperature control is a process in which change of temperature of a space (and objects


collectively there within) is measured or otherwise detected, and the passage of heat energy into
or out of the space is adjusted to achieve a desired average temperature.

10
CHAPTER 2

SENSOR

11
2.1 SENSOR:

A sensor (also called detector) is a converter that measures a physical quantity and converts it
into a signal which can be read by an observer or by an (today mostlyelectronic) instrument. For
example, a mercury-in-glass thermometer converts the measured temperature into expansion and
contraction of a liquid which can be read on a calibrated glass tube. A thermocouple converts
temperature to an output voltage which can be read by a voltmeter. For accuracy, most sensors
are calibrated against knownstandards.

Sensors are used in everyday objects such as touch-sensitive elevator buttons (tactile sensor)
and lamps which dim or brighten by touching the base. There are also innumerable applications
for sensors of which most people are never aware. Applications include cars, machines,
aerospace, medicine, manufacturing and robotics.

A sensor is a device which receives and responds to a signal when touched. A sensor's
sensitivity indicates how much the sensor's output changes when the measured quantity changes.
For instance, if the mercury in a thermometer moves 1 cm when the temperature changes by 1
°C, the sensitivity is 1 cm/°C (it is basically the slope Dy/Dx assuming a linear characteristic).

A good sensor obeys the following rules:

 Is sensitive to the measured property only


 Is insensitive to any other property likely to be encountered in its
application
 Does not influence the measured property

The sensitivity is then defined as the ratio between output signal and measured property. For
example, if a sensor measures temperature and has a voltage output, the sensitivity is a constant
with the unit [V/K]; this sensor is linear because the ratio is constant at all points of
measurement.

2.2 Sensor deviations:

If the sensor is not ideal, several types of deviations can be observed:

12
1) Sensitivity error
2) An offset or bias.
3) Non linearity.
4) Dynamic error.
5) Drift (telecommunication).
6) Long term drift
7) Noise
8) Hysteresis
9) Aliasing errors.

All these deviations can be classified as systematic errors or random errors.

2.3 Resistance thermometer:

Resistance thermometers, also called resistance temperature detectors (RTDs),


are sensors used to measure temperature by correlating the resistance of the RTD element with
temperature. Most RTD elements consist of a length of fine coiled wire wrapped around a
ceramic or glass core. The element is usually quite fragile, so it is often placed inside a sheathed
probe to protect it. The RTD element is made from a pure material, platinum, nickel or copper.
The material has a predictable change in resistance as the temperature changes; it is this
predictable change that is used to determine temperature.

They are slowly replacing the use of thermocouples in many industrial applications below
600 °C, due to higher accuracy and repeatability.

2.4 R Vs T relationship of various metals

Common RTD sensing elements constructed of platinum, copper or nickel have a unique, and
repeatable and predictable resistance versus temperature relationship (R vs T) and operating
temperature range. The R vs T relationship is defined as the amount of resistance change of the
sensor per degree of temperature change. The relative change in resistance (temperature
coefficient of resistance) varies only slightly over the useful range of the sensor.

13
Platinum is a noble metal and has the most stable resistance-temperature relationship over the
largest temperature range. Nickel elements have a limited temperature range because the amount
of change in resistance per degree of change in temperature becomes very non-linear at
temperatures over 572 °F (300 °C). Copper has a very linear resistance-temperature relationship,
however copper oxidizes at moderate temperatures and cannot be used over 302 °F (150 °C).

Platinum is the best metal for RTDs because it follows a very linear resistance-temperature
relationship and it follows the R vs T relationship in a highly repeatable manner over a wide
temperature range. The unique properties of platinum make it the material of choice for
temperature standards over the range of -272.5 °C to 961.78 °C, and is used in the sensors that
define the International Temperature Standard, ITS-90. Platinum is chosen also because of its
chemical inertness.

The significant characteristic of metals used as resistive elements is the linear approximation of
the resistance versus temperature relationship between 0 and 100 °C. This temperature
coefficient of resistance is called alpha, α. The equation below defines α; its units are
ohm/ohm/°C.

the resistance of the sensor at 0°C

the resistance of the sensor at 100°C

Pure platinum has an alpha of 0.003925 ohm/ohm/°C and is used in the construction of
laboratory grade RTDs. Conversely two widely recognized standards for industrial RTDs IEC
60751 and ASTM E-1137 specify an alpha of 0.00385 ohms/ohm/°C. Before these standards
were widely adopted several different alpha values were used. It is still possible to find older
probes that are made with platinum that have alpha values of 0.003916 ohms/ohm/°C and
0.003902 ohms/ohm/°C.

These different alpha values for platinum are achieved by doping; basically carefully introducing
impurities into the platinum. The impurities introduced during doping become embedded in the
lattice structure of the platinum and result in a different R vs. T curve and hence alpha value.

Calibration

14
To characterize the R vs T relationship of any RTD over a temperature range that represents the
planned range of use, calibration must be performed at temperatures other than 0°C and 100°C.
Two common calibration methods are the fixed point method and the comparison method.

1) Fixed point calibration


2) Comparison calibration

2.5 Element types:

There are three main categories of RTD sensors; Thin Film, Wire-Wound, and Coiled Elements.
While these types are the ones most widely used in industry there are some places where other
more exotic shapes are used, for example carbon resistors are used at ultra low temperatures (-
173 °C to -273 °C).

1) Carbon resistor elements


2) Strain free elements
3) Thin film elements
4) Wire-wound elements
5) Coiled elements

The current international standard which specifies tolerance, and the temperature-to-electrical
resistance relationship for platinum resistance thermometers is IEC 60751:2008, ASTM E1137 is
also used in the United States. By far the most common devices used in industry have a nominal
resistance of 100 ohms at 0 °C, and are called Pt100 sensors ('Pt' is the symbol for platinum).
The sensitivity of a standard 100 ohm sensor is a nominal 0.385 ohm/°C. RTDs with a sensitivity
of 0.375 and 0.392 ohm/°C as well as a variety of others are also available.

2.6 Function:

Resistance thermometers are constructed in a number of forms and offer greater


stability, accuracy and repeatability in some cases than thermocouples. While thermocouples use
the Seebeck effect to generate a voltage, resistance thermometers use electrical resistance and
require a power source to operate. The resistance ideally varies linearly with temperature.

The platinum detecting wire needs to be kept free of contamination to remain stable. A platinum
wire or film is supported on a former in such a way that it gets minimal differential expansion or

15
other strains from its former, yet is reasonably resistant to vibration. RTD assemblies made from
iron or copper are also used in some applications. Commercial platinum grades are produced
which exhibit atemperature coefficient of resistance 0.00385/°C (0.385%/°C) (European
Fundamental Interval).[8] The sensor is usually made to have a resistance of 100 Ω at 0 °C. This
is defined in BS EN 60751:1996 (taken from IEC 60751:1995). The American Fundamental
Interval is 0.00392/°C,[9] based on using a purer grade of platinum than the European standard.
The American standard is from the Scientific Apparatus Manufacturers Association (SAMA),
who are no longer in this standards field. As a result the "American standard" is hardly the
standard even in the US.

Measurement of resistance requires a small current to be passed through the device under test.
This can cause resistive heating, causing significant loss of accuracy if manufacturers' limits are
not respected, or the design does not properly consider the heat path. Mechanical strain on the
resistance thermometer can also cause inaccuracy. Lead wire resistance can also be a factor;
adopting three- and four-wire, instead of two-wire, connections can eliminate connection lead
resistance effects from measurements (see below); three-wire connection is sufficient for most
purposes and almost universal industrial practice. Four-wire connections are used for the most
precise applications.

2.7 Advantages and limitations

The advantages of platinum resistance thermometers include:

1) High accuracy
2) Low drift
3) Wide operating range
4) Suitability for precision applications.

Limitations:

RTDs in industrial applications are rarely used above 660 °C. At temperatures above 660 °C it
becomes increasingly difficult to prevent the platinum from becoming contaminated by
impurities from the metal sheath of the thermometer. This is why laboratory standard
thermometers replace the metal sheath with a glass construction. At very low temperatures, say
below -270 °C (or 3 K), because there are very few phonons, the resistance of an RTD is mainly

16
determined by impurities and boundary scattering and thus basically independent of temperature.
As a result, the sensitivity of the RTD is essentially zero and therefore not useful.

Compared to thermistors, platinum RTDs are less sensitive to small temperature changes and
have a slower response time. However, thermistors have a smaller temperature range and
stability.

2.8 Sources of error:

The common error sources of a PRT are:

1) Interchangeability
2) Insulation Resistance
3) Stability
4) Repeatability
5) Hysteresis
6) Stem Conduction
7) Calibration/Interpolation
8) Lead Wire
9) Self Heating
10) Time Response
11) Thermal EMF

2.9 RTDs vs thermocouples:

The two most common ways of measuring industrial temperatures are with resistance
temperature detectors (RTDs) and thermocouples. Choice between them is usually determined by
four factors.

1) Temperature
2) Response time
3) Size
4) Accuracy and stability requirements
2.10 Construction:

17
FIG 2.10.1 CONSTRUCTION OF RTD

These elements nearly always require insulated leads attached. At temperatures below about
250 °C PVC, silicon rubber or PTFE insulators are used. Above this, glass fibre or ceramic are
used. The measuring point, and usually most of the leads, require a housing or protective sleeve,
often made of a metal alloy which is chemically inert to the process being monitored. Selecting
and designing protection sheaths can require more care than the actual sensor, as the sheath must
withstand chemical or physical attack and provide convenient attachment points.

Wiring configurations

Two-wire configuration

Three-wire configuration

Four-wire configuration

2.11 Classifications of RTDs:

Standard platinum Resistance Thermometers (SPRTs).

Secondary Standard platinum Resistance Thermometers (Secondary SPRTs).

Industrial PRTs

2.12 Applications:
Sensor assemblies can be categorized into two groups by how they are installed or interface with
the process: immersion or surface mounted.

1) Immersion sensors
2) Surface mounted sensors

Immersion sensors generally have the best measurement accuracy because they are in direct
contact with the process fluid. Surface mounted sensors are measuring the pipe surface as a close
approximation of the internal process fluid.

18
2.13 History:

The application of the tendency of electrical conductors to increase their electrical


resistance with rising temperature was first described by Sir William Siemens at the Bakerian
Lecture of 1871 before the Royal Society of Great Britain. The necessary methods of
construction were established by Callendar , Griffiths, Holborn and Wein between 1885 and
1900.

Resistance thermometer elements can be supplied which function up to 1000 °C. The relation
between temperature and resistance is given by the Callendar-Van Dusen equation,

Here, is the resistance at temperature T, is the resistance at 0 °C, and the constants (for
an alpha=0.00385 platinum RTD) are

Since the B and C coefficients are relatively small, the resistance changes almost linearly with
the temperature.

2.14 Pt100 Platinum Resistance Thermometers(Pt100 SENSORS):

Platinum resistance thermometers (PRTs) offer excellent accuracy over a wide temperature
range (from-200 to +850 °C). Standard Sensors are are available from many manufacturers with
various accuracy specifications and numerous packaging options to suit most applications.
Unlike thermocouples, it is not necessary to use special cables to connect to the sensor.

19
The principle of operation is to measure the resistance of a platinum element. The most common
type (PT100) has a resistance of 100 ohms at 0 °C and 138.4 ohms at 100 °C. There are also
PT1000 sensors that have a resistance of 1000 ohms at 0 °C.

The relationship between temperature and resistance is approximately linear over a small
temperature range: for example, if you assume that it is linear over the 0 to 100 °C range, the
error at 50 °C is 0.4 °C. For precision measurement, it is necessary to linearise the resistance to
give an accurate temperature. The most recent definition of the relationship between resistance
and temperature is International Temperature Standard 90 (ITS-90).

FIG 2.14.1 Pt100 SENSOR

This linearisation is done automatically, in software, when using Pico signal conditioners. The
linearisation equation is:

Rt = R0 * (1 + A* t + B*t2 + C*(t-100)* t3)

Where:

Rt is the resistance at temperature t,

R0 is the resistance at 0°C, and


A=3.9083E-3
B =-5.775E-7

20
C =-4.183E-12(below0°C),or
C = 0 (above 0 °C)

For a PT100 sensor, a 1 °C temperature change will cause a 0.384 ohm change in resistance, so
even a small error in measurement of the resistance (for example, the resistance of the wires
leading to the sensor) can cause a large error in the measurement of the temperature. For
precision work, sensors have four wires- two to carry the sense current, and two to measure the
voltage across the sensor element. It is also possible to obtain three-wire sensors, although these
operate on the (not necessarily valid) assumption that the resistance of each of the three wires is
the same.

The current through the sensor will cause some heating: for example, a sense current of 1 mA
through a 100 ohm resistor will generate 100 µW of heat. If the sensor element is unable to
dissipate this heat, it will report an artificially high temperature. This effect can be reduced by
either using a large sensor element, or by making sure that it is in good thermal contact with its
environment.

For example, a 100 µV voltage measurement error will give a 0.4 °C error in the temperature
reading. Similarly, a 1 µA error in the sense current will give 0.4 °C temperature error.

Because of the low signal levels, it is important to keep any cables away from electric cables,
motors, switchgear and other devices that may emit electrical noise. Using screened cable, with
the screen grounded at one end, may help to reduce interference. When using long cables, it is
necessary to check that the measuring equipment is capable of handling the resistance of the
cables. Most equipment can cope with up to 100 ohms per core.

The type of probe and cable should be chosen carefully to suit the application. The main issues
are the temperature range and exposure to fluids (corrosive or conductive) or metals. Clearly,
normal solder junctions on cables should not be used at temperatures above about 170 °C.

Sensor manufacturers offer a wide range of sensors that comply with BS1904 class B (DIN
43760): these sensors offer an accuracy of ±0.3 °C at 0 °C. For increased accuracy, BS1904 class
A (±0.15 °C) or tenth–DIN sensors (±0.03 °C). Companies like Isotech can provide standards

21
with 0.001 °C accuracy. Please note that these accuracy specifications relate to the SENSOR
ONLY: it is necessary to add on any error in the measuring system as well.

The function for temperature value acquisition (C++)

The following code estimates a Pt100 or Pt1000 sensor's temperature from its current resistance
(input parameter r).

float GetPt100Temperature(float r)
{
float const Pt100[] = { 80.31, 82.29, 84.27, 86.25, 88.22, 90.19, 92.16, 94.12, 96.09, 98.04,
100.0, 101.95, 103.9, 105.85, 107.79, 109.73, 111.67, 113.61, 115.54, 117.47,119.4, 121.32,
123.24, 125.16, 127.07, 128.98, 130.89, 132.8, 134.7, 136.6,138.5, 140.39, 142.29, 157.31,
175.84, 195.84 };
int t = -50, i = 0, dt = 0;
if (r > Pt100[0])
while (250 > t)
{
dt = (t < 110) ? 5 : (t > 110) ? 50 : 40;
if (r < Pt100[++i])
return t + (r - Pt100[i-1]) * dt / (Pt100[i] - Pt100[i-1]);
t += dt;
};
return t;
}
float GetPt1000Temperature(float r)
{
return GetPt100Temperature(r / 10);
}

22
CHAPTER3

TEMPERATURE READER (CONTROLLER)

23
3.1 Introduction to Temperature Controllers
How do Temperature Controllers work?
To accurately control process temperature without extensive operator involvement, a temperature
control system relies upon a controller, which accepts a temperature sensor such as a
thermocouple or RTD as input. It compares the actual temperature to the desired control
temperature, or set point, and provides an output to a control element. The controller is one part of
the entire control system, and the whole system should be analyzed in selecting the proper
controller. The following items should be considered when selecting a controller:

1. Type of input sensor (thermocouple, RTD) and temperature range


2. Type of output required (electromechanical relay, SSR, analog output)
3. Control algorithm needed (on/off, proportional, PID)
4. Number and type of outputs (heat, cool, alarm, limit)

3.2 What Are the Different Types of Controllers, and How Do They Work?
There are three basic types of controllers: on-off, proportional and PID. Depending upon the
system to be controlled, the operator will be able to use one type or another to control the process.

On/Off Control
An on-off controller is the simplest form of temperature control device. The output from the device
is either on or off, with no middle state. An on-off controller will switch the output only when the
temperature crosses the setpoint. For heating control, the output is on when the temperature is
below the setpoint, and off above setpoint. Since the temperature crosses the setpoint to change the
output state, the process temperature will be cycling continually, going from below setpoint to
above, and back below. In cases where this cycling occurs rapidly, and to prevent damage to
contactors and valves, an on-off differential, or “hysteresis,” is added to the controller operations.
This differential requires that the temperature exceed setpoint by a certain amount before the
output will turn off or on again. On-off differential prevents the output from “chattering” or
making fast, continual switches if the cycling above and below the setpoint occurs very rapidly. On-
off control is usually used where a precise control is not necessary, in systems which cannot handle

24
having the energy turned on and off frequently, where the mass of the system is so great that
temperatures change extremely slowly, or for a temperature alarm. One special type of on-off
control used for alarm is a limit controller. This controller uses a latching relay, which must be
manually reset, and is used to shut down a process when a certain temperature is reached.

Proportional Control
Proportional controls are designed to eliminate the cycling associated with on-off control. A
proportional controller decreases the average power supplied to the heater as the temperature
approaches setpoint. This has the effect of slowing down the heater so that it will not overshoot the
setpoint, but will approach the setpoint and maintain a stable temperature. This proportioning
action can be accomplished by turning the output on and off for short time intervals. This "time
proportioning" varies the ratio of “on” time to "off" time to control the temperature. The
proportioning action occurs within a “proportional band” around the setpoint temperature.
Outside this band, the controller functions as an on-off unit, with the output either fully on (below
the band) or fully off (above the band). However, within the band, the output is turned on and off
in the ratio of the measurement difference from the setpoint. At the setpoint (the midpoint of the
proportional band), the output on:off ratio is 1:1; that is, the on-time and off-time are equal. if the
temperature is further from the setpoint, the on- and off-times vary in proportion to the
temperature difference. If the temperature is below setpoint, the output will be on longer; if the
temperature is too high, the output will be off longer.

PID Control
The third controller type provides proportional with integral and derivative control, or PID. This
controller combines proportional control with two additional adjustments, which helps the unit
automatically compensate for changes in the system. These adjustments, integral and derivative,
are expressed in time-based units; they are also referred to by their reciprocals, RESET and
RATE, respectively. The proportional, integral and derivative terms must be individually adjusted
or “tuned” to a particular system using trial and error. It provides the most accurate and stable
control of the three controller types, and is best used in systems which have a relatively small mass,
those which react quickly to changes in the energy added to the process. It is recommended in
systems where the load changes often and the controller is expected to compensate automatically

25
due to frequent changes in setpoint, the amount of energy available, or the mass to be controlled.
OMEGA offers a number of controllers that automatically tune themselves. These are known as
autotune controllers.

Standard Sizes
Since temperature controllers are generally mounted inside an instrument panel, the panel must be
cut to accommodate the temperature controller. In order to provide interchangeability between
temperature controllers, most temperature controllers are designed to standard DIN sizes. The
most common DIN sizes are shown below.

FIG 3.2.1 STANDARD PANEL SIZES

3.3 SELEC TC303:

Selec TC303 temperature controller is a single set point controller.


//Manufacturer SELEC Controls Pvt. Ltd Code No SELEC TC303//
Features:
Single display

26
4 digits

7 segment LED

TC / RTD input PID

ON/OFF control

Single set point °C / °F

selectable Field selectable control output (Relay or SSR)

Auxiliary output: Relay

27
Easy to use.

FF

SFIG 3.3.1 TEMPERATURE READER (CONTROLLER)

FIGFI

28
CHAPTER4

PIC16F877A and RS232

29
4.1 PIC16F877A:
This powerful (200 nanosecond instruction execution) yet easy-to-program (only 35 single
word instructions) CMOS FLASH-based 8-bit microcontroller packs Microchip's powerful PIC®
architecture into an 40- or 44-pin package and is upwards compatible with the PIC16C5X,
PIC12CXXX and PIC16C7X devices. The PIC16F877A features 256 bytes of EEPROM data
memory, self programming, an ICD, 2 Comparators, 8 channels of 10-bit Analog-to-Digital
(A/D) converter, 2 capture/compare/PWM functions, the synchronous serial port can be
configured as either 3-wire Serial Peripheral Interface (SPI™) or the 2-wire Inter-Integrated
Circuit (I²C™) bus and a Universal Asynchronous Receiver Transmitter (USART). All of these
features make it ideal for more advanced level A/D applications in automotive, industrial,
appliances and consumer applications.

Features

2 PWM 10-bit
256 Bytes EEPROM data memory
ICD
25mA sink/source per I/O
Self Programming
Parallel Slave Port

Parameter Name Value

Program Memory Type Flash

Program Memory (KB) 14

CPU Speed (MIPS) 5

RAM Bytes 368

Data EEPROM (bytes) 256

Digital Communication Peripherals 1-A/E/USART, 1-MSSP(SPI/I2C)

30
Capture/Compare/PWM Peripherals 2 CCP

Timers 2 x 8-bit, 1 x 16-bit

ADC 8 ch, 10-bit

Comparators 2

Temperature Range (C) -40 to 125

Operating Voltage Range (V) 2 to 5.5

Pin Count 40

TABLE 4.1.1 FEATURES OF PIC16F877A

FIG 4.1.1 PIC16F877A

4.2 RS232:

In telecommunications, RS-232 is the traditional name for a series of standards for serial
binary single-ended data and control signals connecting between a DTE (data terminal
equipment) and a DCE (data circuit-terminating equipment). It is commonly used in computer
serial ports. The standard defines the electrical characteristics and timing of signals, the meaning
of signals, and the physical size and pinout of connectors. The current version of the standard

31
is TIA-232-F Interface between Data Terminal Equipment and Data Circuit-Terminating
Equipment Employing Serial Binary Data Interchange, issued in 1997.

An RS-232 serial port was once a standard feature of a personal computer, used for connections
to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral
devices. However, the low transmission speed, large voltage swing, and large standard
connectors motivated development of the Universal Serial Bus, which has displaced RS-232
from most of its peripheral interface roles. Many modern personal computers have no RS-232
ports and must use an external USB-to-RS-232 converter to connect to RS-232 peripherals. RS-
232 devices are still found, especially in industrial machines, networking equipment, or scientific
instruments.

History

RS-232 was first introduced in 1962 by the Radio Sector of the EIA. The original DTEs were
electromechanical teletypewriters, and the original DCEs were (usually) modems.
When electronic terminals (smart and dumb) began to be used, they were often designed to be
interchangeable with teletypewriters, and so supported RS-232. The C revision of the standard
was issued in 1969 in part to accommodate the electrical characteristics of these devices.

Many fields (for example, laboratory automation, surveying) provide a continued demand for
RS-232 I/O due to sustained use of very expensive but aging equipment. It is often far cheaper to
continue to use RS-232 than it is to replace the equipment. Additionally, modern industrial
automation equipment, such as PLCs, VFDs, servo drives, and CNC equipment are
programmable via RS-232. Some manufacturers have responded to this demand: Toshiba re-
introduced the DE-9M connector on the Tecra laptop.

Serial ports with RS-232 are also commonly used to communicate to headless systems such
as servers, where no monitor or keyboard is installed, during boot when operating system is not
running yet and therefore no network connection is possible. An RS-232 serial port can
communicate to some embedded systems such as routers as an alternative to network mode of
monitoring.

32
Signals:

The following table lists commonly used RS-232 signals and pin assignments.[9] See serial port
(pinouts) for non-standard variations including the popular DE-9 connector.

Signal Origin DB-


Name Typical purpose Abbreviation DTE DCE 25 pin

Data Terminal
Indicates presence of DTE to DCE. DTR ● 20
Ready

Data Carrier
DCE is connected to the telephone line. DCD ● 8
Detect

DCE is ready to receive commands or


Data Set Ready DSR ● 6
data.

DCE has detected an incoming ring


Ring Indicator RI ● 22
signal on the telephone line.

DTE requests the DCE prepare to


Request To Send RTS ● 4
receive data.

Clear To Send Indicates DCE is ready to accept data. CTS ● 5

Transmitted Data Carries data from DTE to DCE. TxD ● 2

Received Data Carries data from DCE to DTE. RxD ● 3

Common
GND common 7
Ground

Protective
PG common 1
Ground

TABLE 4.2.1 SIGNALS IN RS232

33
The signals are named from the standpoint of the DTE. The ground signal is a common return for
the other connections. The DB-25 connector includes a second "protective ground" on pin 1.

Data can be sent over a secondary channel (when implemented by the DTE and DCE devices),
which is equivalent to the primary channel.

Pin assignments are described in following table:

Signal Pin

Common Ground 7 (same as primary)

Secondary Transmitted Data (STD) 14

Secondary Received Data (SRD) 16

Secondary Request To Send (SRTS) 19

Secondary Clear To Send (SCTS) 13

Secondary Carrier Detect (SDCD) 12

TABLE 4.2.2 PIN ASSIGNMENTS

Ring Indicator' (RI), is a signal sent from the modem to the terminal device. It indicates to the
terminal device that the phone line is ringing. In many computer serial ports, a hardware
interrupt is generated when the RI signal changes state.

Certain personal computers can be configured for wake-on-ring, allowing a computer that is
suspended to answer a phone call.

Cables:

The standard does not define a maximum cable length but instead defines the maximum
capacitance that a compliant drive circuit must tolerate. A widely used rule of thumb indicates
that cables more than 50 feet (15 m) long will have too much capacitance, unless special cables
are used. By using low-capacitance cables, full speed communication can be maintained over
larger distances up to about 1,000 feet (300 m). For longer distances, other signal standards are
better suited to maintain high speed.

Other serial interfaces similar to RS-232:

34
RS-422 (a high-speed system similar to RS-232 but with differential signaling)

RS-423 (a high-speed system similar to RS-422 but with unbalanced signaling)

RS-449 (a functional and mechanical interface that used RS-422 and RS-423 signals - it never
caught on like RS-232 and was withdrawn by the EIA)

RS-485 (a descendant of RS-422 that can be used as a bus in multidrop configurations)

MIL-STD-188 (a system like RS-232 but with better impedance and rise time control)

EIA-530 (a high-speed system using RS-422 or RS-423 electrical properties in an EIA-232


pinout configuration, thus combining the best of both; supersedes RS-449)

EIA/TIA-561 8 Position Non-Synchronous Interface Between Data Terminal Equipment and


Data Circuit Terminating Equipment Employing Serial Binary Data Interchange

EIA/TIA-562 Electrical Characteristics for an Unbalanced Digital Interface (low-voltage version


of EIA/TIA-232)

TIA-574 (standardizes the 9-pin D-subminiature connector pinout for use with EIA-232
electrical signalling, as originated on the IBM PC/AT)

SpaceWire (high-speed serial system designed for use on board spacecraft).

Serial line analyzers are available as standalone units, as software and interface cables for
general-purpose logic analyzers, and as programs that run in common personal computers.

35
FIG 4.2.1 RS232 cable

36
CHAPTER 5

GRAPHICAL DISPLAY

37
5.1 Graphical LCD 128*64:

Description:

This is a framed graphical LCD 128*64 with LED backlight. This unit is a very clear STN type
LCD with a simple command interface. This new module includes the negative voltage circuitry
on board!

Dimensions:

 Overall: 75x52.7mm
 Viewable area: 55.01x27.49mm

FIG 5.1.1 Graphical LCD 128*64

5.2 Interfacing of PIC16F877A with 128x64 graphical display:

Components/ Softwares:
MPLAB IDE (PIC microcontrollers simulator) PIC BURNER 3 with software to load the code
LCD (Displaytech 162A) Computer System with Windows operating system and RS 232 cable
PIC16F877 Microcontroller +5V D.C Power Supply Resistors - 10K Ω-1,50Ω-1 Capacitors - 27
µ F-2 Potentiometers - 10K Ω -1 20MHz Crystal oscillator SPST switches -1
Procedure:
Write the assembly code in MPLAB IDE simulator , compile it and check for errors Once the
code was error free, run it and check the output in the simulator. After checking the code in the

38
simulator, load the code (in .HEX format) into PIC16F877 microcontroller using PIC
BURNER3. Make connections as shown in the circuit diagram. Switch on the power supply and
observe "IITK" displayed in the LCD.

Initializing LCD by sequence of instructions Executing commands depending on our settings in


the LCD Writing data into the DRAM locations of LCD in the Standard Character Pattern of
LCD

MPLABIDE is a free software which can be downloaded from the websitewww.microchip.com

Working with MPLABIDE :

MPLABIDE is a simulator for PIC microcontrollers to write and edit the code in assembly
language, compile it and also to run the code. Output can be verified using simulator. Steps to
Use MPLABIDE

After Installing the software MPLABIDEv7.2, open MPLABIDE. To built a new project, open
Project Project Wizard Project wizard New Device 16F877 Location
(C:\ProgramFiles\‐Microchip\MPASM Suite\MPASMWIN.EXE) Next <Project
name>&<Project Directory> Next (Add file "f877tmpo.asm" which was located in programfiles
microchip MPASM Suite Template Object) (Add file "16f877.lkr" which was located in program
files microchip MPASM Suite LKR) Next Finish To have more clear refer to MPLABIDE help
files. After building the project open the editor f877tmpo.asm and write the assembly code After
writing the assembly code in the editor, build the project by clicking on the following option
Project Build all Check for the errors in the output window View Output Once the error free
code was made, simulate the code by following option Debugger Select Tool MPLAB SIM
Simulator options are Step into - Each time only one instruction will be executed (Single
stepping mode) Run - To run the whole code at once. Animate - to animate the executing the
code Additional things: To view DRAM, program memory, SFRs, and External memory use the
option VIEW To set break points in the code (where simulation stops at that point). Debugger
Breakpoints To stop the simulation Debugger Halt

39
After checking the code in the simulator, the code (file with .HEX extension) is loaded into
16F877 microcontroller using PIC BURNER 3. PIC BURNER3

PIC BURNER3 can be used to program PIC microcontrollers. The steps to be followed to
program the IC safely are as follows.

Connect the PIC BURNER3 through RS232 Port to computer system with windows98 as
operating system. Execute the file "icprog" which was in the software that comes with PIC
BURNER3. Set the device as PIC16F877 Switch on the power supply of PIC BURNER3
Settings Hardware { JDM Programmer,Com1,Direct I/O} Settings Hardware check 1. on
clicking "Enable Data out", Data in must be clicked automatically 2. on clicking Enable MCLR,
red LED on the PICBURNER3 must glow Settings Options Confirmation [ Erasing the
devise,Code Protecting the Devise] Settings Options MISC Process Priority Normal Settings
Options Programming Verify After Programming. Remaining options keep them at default
settings. [Refer Manual of PICBURNER3 for detail] Now insert the 16F877 microcontroller into
the slot provided on the PICBURNER3 as the direction specified in the manual of
PICBURNER3. load the .hex file File open file Command Erase All Command Blank Check
Then there should be a notice on the window that "Device is Blank " Command Program All
Command Blank Check Then there should be a notice on the window that "Device is not blank at
address 0x0000H". Close the window, remove the IC from the PIC BURNER3 and switch off
the power supply for PIC BURNER3.

FIG5.2.1 Interfacing of PIC16F877A with 128x64 graphical display

40
CHAPTER6

PROCEDURE

41
6.1 PROCEDURE:
Ensure proper electrical connections.
Place the sensor (tip probe) in a heat source.
It will be read and shown in selecTC303.
Then, the output from it is given to the microcontroller and program gets executed.
From the PIC16F877A, RS232 cable is linked to system and values are seen.
Then, it is given to graphical display.

FIG6.1 BLOCK DIAGRAM OF TEMPERATURE


MEASUREMENT SETUP:
128*64
TEMPERATURE TEMPERATURE PIC16F877A GRAPHICAL
RS232 DISPLAY
SENSOR READER/CONTROLLER
MICROCONTROLLER UNIT
(Pt100)

COST ESTIMATION:

Sensor Rs.480
Temperature controller Rs.1200
Microcontroller chip(kit) Rs.2500
Graphical display Rs.800

42
CONCLUSION

This can be used for measuring, controlling and acquisition of the temperatures in the
engineering systems such as IC Engines, Boilers, etc. Graphs can be drawn between a
temperature and time.

43

Você também pode gostar