PMT PRNS1 SAUDI ARABIAN OIL COMPANY

B.ANDERS
CERT

PROJECT DOCUMENT
ENG’G

YY.GU
ISSUED FOR CONSTRUCTION
DESCRIPTION

DATA SHEET FOR ARCHITECTURAL


SUBSTATION SS-329

Jazan IGCC Power Block


10-01525-0004
JO/EWO

A29-A-DAT-VE-607659
DATE

31/MAY/16
REV.
NO.
00

DISCIPLINE
ENGINEER

________________

DATE ___________

PROJECT
ENGINEER

________________

DATE ___________

CERTIFIED

________________

DATE ___________

CONSTRUCTION
AGENCY

________________

DATE ___________

ISSUED FOR
00 31/May/2016 YY.Gu CH.Yang YZ.Cui B.Anders
OPERATIONS
CONSTRUCTION
________
Rev Date Description Prep Chk Appv’d PM SAPMT

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
REVISION CERTIFICATE

OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. 00

(DCC)NO. 10-01525-0004--001_

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_SS-329 DAT 1


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

B.ANDERS

Owner’s Name: Saudi Aramco


CERT

Name of Building: Substation


Project Title: Jazan IGCC Ref. No: BI-10-01525
Project Number: 10-01525-0004 Date: 31 May 2016
ENG’G

YY.GU

Project Site Location: Jazan

1. General
These data sheets contain Architectural, HVAC, Electrical, Telecommunications / Security,
Plumbing, Civil / Structural, Fire Protection and Fire Detection information that may be conveyed
from the owner to the project design team or from the project design team leaders to the team
design members. This data may be provided by the owner or developed by the project design
ISSUED FOR CONSTRUCTION

team and approved by the owner.


DESCRIPTION

The floor level definition used in this document identifies the building levels starting at grade as
First Floor, Second Floor, Third Floor, etc. Ground Floor is not used.
Building Code: Saudi Aramco Building Code, SAES-M-100
International Building Code (IBC) 2009 edition.
Elevation:
Finished Grade: - 100.000 m
Floor Elevation (First Floor): - 100.300 m
Floor Elevation (Second Floor): - N/A m
Floor Elevation (Third Floor): - N/A m
Special Requirements:
Description Yes No
Blast Resistant Construction
10-01525-0004
JO/EWO

Windows Permitted
Floor Drains Permitted
Furniture/Furnishings
Landscaping
DATE

31/MAY/16

Interior Design
Parking at Building
# of cars 3
REV.
NO.
00

Handicapped Parking
Signage/Graphics
DISCIPLINE
ENGINEER
Monorail Crane _______ tons capacity
________________
Existing Colours or Textures
to Be Matched
DATE ___________
Existing Siding/Roofing Profiles
PROJECT
ENGINEER
to Be Matched
________________
Designed for Future Expansion
Visual Access to Control Room
DATE ___________
Total Occupancy None
CERTIFIED
General Comments:
________________

DATE ___________

CONSTRUCTION
AGENCY

________________

DATE ___________

OPERATIONS
________

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 2


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

2. Architectural
B.ANDERS
CERT

2.1 Building Code Analysis

Substation
ENG’G

YY.GU

Code Reference
Building Classification IBC 2009
(SAES-M-100)
Occupancy Classification Group F-2 Section 306.2

Construction Type IB Section 601


ISSUED FOR CONSTRUCTION

Required 91.2m
Maximum Travel
DESCRIPTION

Table 1016.1
Distance
ACTUAL <23m

Required 1 or 2
No. Of Exits Table 1021.1
Refer to Floor
ACTUAL Plan

Fire Protection Systems Extinguisher SAES-B-014

Fire Separation Wall (Fire


2-Hr. Required for All walls SAES-P-119
Rated Wall)
10-01525-0004
JO/EWO

Fire Fire
Electrical Area
External: - Exclusion Internal: - Exclusion
Classification
Zone Zone
DATE

31/MAY/16
REV.
NO.
00

DISCIPLINE
ENGINEER

________________

DATE ___________

PROJECT
ENGINEER

________________

DATE ___________

CERTIFIED

________________

DATE ___________

CONSTRUCTION
AGENCY

________________

DATE ___________

OPERATIONS
________

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 3


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

2.2 Room Finish Schedules: -


B.ANDERS
CERT

Mechanical Room
Switchgear Room

PSA/SAS Room
Telecom Room
Room Name &

Battery Room
Function
ENG’G

Air Lock
YY.GU

Element
Definitions

Carpet
Chemical Resistant
ISSUED FOR CONSTRUCTION

Seamless Monolithic
DESCRIPTION

Raised Access Floor


Vinyl Composition Tile
Floors

Vinyl Composition Tile


(Anti-static)
Slip Resistant Ceramic Tile
Sealer on Concrete
Hardened Concrete Finish
Exposed Concrete
Epoxy Paint on Render
Boards Bases

Coved Ceramic Tile


Cove Vinyl Base
10-01525-0004
JO/EWO

Bulletin Boards
Chalk/Marker Boards
CMU Masonry
DATE

Exposed Concrete
31/MAY/16

¾” Plywood Backboard
Modular Office Partition
REV.
NO.

Vinyl Wall Covering


00

Operable Steel Partition


DISCIPLINE Reinforced Concrete
Walls

ENGINEER

________________ Ceramic Tile


DATE ___________
Chemical Resistant Tile -
2200 Height
PROJECT
ENGINEER
Plaster CMU Walls
________________ Gypsum Board on Metal Stud
DATE ___________ Pre-Cast Concrete Panels
CERTIFIED Acoustical Wall Panel
________________ Painted
DATE ___________ Exposed Construction
Metal Liner Panels
Ceilings

CONSTRUCTION
AGENCY Painted
________________ Gypsum Board
DATE ___________
Acoustical Tile
Plaster
OPERATIONS
________

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 4


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

2.3. Materials and Construction: -


B.ANDERS
CERT

Primary Structure Exterior Walls


Steel Frame Concrete Masonry Units (CMU)
Reinforced Concrete Frame Brick Veneer
ENG’G

YY.GU

Pre-Engineered System Precast Concrete Panels


Load-Bearing Reinf. Masonry (CMU) Cast-in-place Concrete
Load-Bearing Precast Concrete Walls Metal Panels
Load-Bearing Cast-in-Place Walls Light Gage Steel Framing
Blast Resistant Wood Sheathing
Other ________________________ Plaster
Store Front System
ISSUED FOR CONSTRUCTION

Painted
Insulated
DESCRIPTION

Other includes: reinforced. Concrete column

Elevated Levels Doors


Single-Ply Membrane INT. EXT.
Built-up Metal Door
Uninsulated Metal Panel Pressed Steel Frame
Insulated Metal Panel Wood
Fibre glass/Plastic Aluminium and Glass
Bare Concrete Fiberglass
Sealed/Coated Concrete Painted
Other Access Panels Galvanized
Laminated
10-01525-0004
JO/EWO

Roll-up
Canopy
Other ________________
DATE

31/MAY/16

Roof Systems Windows


Fully Adhered EPDM Membrane Steel Frame
Built-up Roofing Aluminium Frame
REV.
NO.
00

Un insulated Metal Panel Safety Glass (Type: Bullet Resistant Glass)


Insulated Metal Panel Insulating Glass
DISCIPLINE
ENGINEER Fibre glass/Plastic Fixed
________________ Bare Concrete Operable
DATE ___________ Sealed/Coated Concrete Tinted Glass
Other light weight concrete to slope
PROJECT
ENGINEER Other Insulation
________________

DATE ___________ Roof Structures Louvers


CERTIFIED Metal Form Deck Operable
________________ Concrete Slab Fixed
DATE ___________ Wood Formed Concrete Slab Bird screen
Metal Deck Only Steel
CONSTRUCTION Precast Concrete Double Tee Beam Aluminium
AGENCY
Composite (Type: _____________) Blast Resistant
________________
Standing Seam Roof System Other ________________
DATE ___________
Other ________________

OPERATIONS
________

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 5


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

3. Heating, Ventilation, and Air Conditioning (HVAC)


B.ANDERS
CERT

Heating: No Electric Steam Hot Water Gas Other ___


Ventilation: No Blow Through Draw Through Gravity
ENG’G

YY.GU

Air Conditioning: No
Cooling Medium: Chilled Water DX _________________
System: Packaged Split _________________
Condenser: Water Cooled Air Cooled
Corrosion Resistant Coil Coating: Air Handler Condenser
ISSUED FOR CONSTRUCTION

Stand by Capacity _100 % (Description).


DESCRIPTION

Air Distribution System: Multi Zone Single Zone Other ______________


Thermostat Control: Pneumatic Electronic
Motor: Standard Explosion Proof
Wall Louvers: Yes No Dust Filter: Yes No
Air Intake Stack: Yes No Sand Filter: Yes No
Chemical Filter: Yes No
Equipment Heat Loads:
Electrical Equipment: 92.38 (kW) (kW)
10-01525-0004
JO/EWO

DCS Equipment: (kW) (kW)


Thermostat Setting Temperatures, % Relative Humidity and Pressure deviations from the Aramco
standards or as required by the process or equipment: -
DATE

31/MAY/16

Room Temperature(ºC) RH (%) Pressure (Pa)


Refer to HVAC file: A29-A-DOC-VE-015122 item2.2
REV.
NO.
00

DISCIPLINE
Special Ventilation System Requirements:
ENGINEER
For Whole Building: - Yes No
________________

DATE ___________ Partial Area: - Exhaust Battery Room based on SAES-P-103


PROJECT Fresh Air Makeup Controlled: Yes No
ENGINEER

________________ Air Intake Shutdown Capability: Automatic Manual


DATE ___________
Building Pressurization: No Pressure: 25_ Pascal (Pa)
CERTIFIED
Building Purging: - Yes No Gas Detection Alarm: - Yes No
________________

DATE ___________ 4. Electrical


CONSTRUCTION Power Source for Building: - SEC ____________________S/S #: - __A29-329-MCC-001_____
AGENCY

________________
Interior Electrical Light: - Incandescent Lamp Fluorescent Lamp Other ____________
DATE ___________ Special Grounding Yes
Interior Wiring Yes
OPERATIONS
________
Exterior Wiring Yes

DATE ___________
Exterior Lighting: - Yes No
Other Requirements
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 6


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

5. Communication
B.ANDERS
CERT

Communication Standards Bodies: -


USA – TIA/EIA, BICSI, NFPA, IEEE Yes No
ENG’G

YY.GU

Other
Communication Requirements: -
Telephone Yes No
Closed Circuit TV Yes No
Other
ISSUED FOR CONSTRUCTION

Security Access Control: - Yes No


DESCRIPTION

6. Building Fire Protection and Safety


Description Yes No Description Yes No
Fire Detection/Alarm: - Fire Suppression: -
Smoke Detector Hose Cabinets
Heat Detector Sprinkler System
Fire Alarm Box Clean Agent Fire
Audible/Visual Alarm Extinguishing System *
10-01525-0004
JO/EWO

Fire Alarm Panel Portable Fire Extinguishers: -


10-lb (4.5-kg) or 25- lb (11.4-kg) ABC (Ammonium
Phosphate) Extinguisher
Sprinkler System 10-lb (4.5-kg) CO2
Pressure Switch Extinguisher
DATE

31/MAY/16

100-lb (45.3-kg) CO2 Wheeled


Extinguisher
REV.
NO.
00

Fixed Fire Suppression Building Hydrant (Standpipes): -


Discharge Class I Class II Class III
DISCIPLINE
ENGINEER Automatic Sprinkler Miscellaneous: -
________________ Actuation Emergency Lighting
DATE ___________ Sprinkler Flow Switch
PROJECT
ENGINEER
Description Yes No
________________

DATE ___________ Safety: -


CERTIFIED Breathing Air System
________________
Combustible Gas Detectors
DATE ___________

Toxic Gas Sensors


CONSTRUCTION
AGENCY Oxygen Analysis
________________

DATE ___________

7. Plumbing
OPERATIONS 7.1 Plumbing Codes
________

Uniform Plumbing Code (year: _2009)


DATE ___________
Local/County/Municipal Plumbing Code (year: _______)
APPROVAL/CERTIFICATION REQUIREMENTS,

(Or Adopted Plumbing Code ________, year: _______, date: _______)


OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 7


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

(In the absence of any locally adopted plumbing code, building plumbing system will be designed
B.ANDERS

in accordance with) the latest edition of the International Plumbing Code (IPC) 2009 and SAES-M-
CERT

100 Saudi Aramco Building Code.


ENG’G

YY.GU

7.2 Plumbing Systems

Description Yes No Description Yes No


Domestic Water Fire Water
Cold Water Natural Gas
Hot Water Sanitary Sewer
Acid Resistant
ISSUED FOR CONSTRUCTION

Storm Drain Instrument Air


DESCRIPTION

Cooling Tower Steam


Supply Condensate Return
Return Oily Water Sewer
Potable/Raw
7.3 Plumbing Fixtures and Specialties

Description Yes No Description Yes No


Water Closet Emergency Shower
Ablution Faucets Emergency Eye Wash
Lavatory Electrical Water Cooler
Kitchen Sink Hose Bib
10-01525-0004
JO/EWO

Service Sink Shower Stall


Lab Sink Dishwasher
Floor Drain Rough-in (for Ice Maker)
Garbage Disposal Vacuum Pump
Water Heater Backflow Preventer
DATE

31/MAY/16

Grease Interceptors Pressure Regulator


Oil Interceptor EL. Drinking Fountain
REV.
NO.
00

DISCIPLINE
ENGINEER

________________

DATE ___________

PROJECT
ENGINEER

________________

DATE ___________

CERTIFIED

________________

DATE ___________

CONSTRUCTION
AGENCY

________________

DATE ___________

OPERATIONS
________

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 8


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9
PMT PRNS1
SAUDI ARABIAN OIL COMPANY

8. Notes
B.ANDERS
CERT

1. Floor drain, eyewash and hose bib is only in battery room.


ENG’G

YY.GU

2. Sanitary sewer is for battery room.


3. Cabinets for storing maintenance tools and safety equipment should be provided in battery room.
4. Reference drawings:
A29-R-ARC-VA-120519 First Floor Plan
A29-R-SDT-VA-120520 Roof Plan
ISSUED FOR CONSTRUCTION

A29-R-ARC-VA-120521 Elevations
DESCRIPTION

A29-R-ARC-VA-120522 Sections
A29-R-ARC-VB-120523 Wall Sections
A29-R-SCH-VA-120525 Door & Finishing Schedule
A00-S-GAP-VA-453004 Final Grading & Drainage Overall Plot Plan
A29-K-HVA-VA-015130 Equipment Layout For SS-329
A29-P-EDT-VA-238354 13.8kV Substation Layout (SS-329)
A29-B-FPS-VA-237773 SS-329 Fire Extinguisher Location Plan
10-01525-0004
JO/EWO
DATE

31/MAY/16
REV.
NO.
00

DISCIPLINE
ENGINEER

________________

DATE ___________

PROJECT
ENGINEER

________________

DATE ___________

CERTIFIED

________________

DATE ___________

CONSTRUCTION
AGENCY

________________

DATE ___________

OPERATIONS
________

DATE ___________
APPROVAL/CERTIFICATION REQUIREMENTS,
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


THIS INDICATES THAT REV. NO. ___00___
REVISION CERTIFICATE

(DCC)NO. __10-01525-0004--001___

PROJECT SPECIFICATION DWG. TYPE PLANT INDEX DOC. SHT. NO. REV. NO.

DATA SHEET FOR ARCHITECTURAL_ SS-329 DAT 9


A29 A VE-607659
ELECTRICAL POWER DISTRIBUTION & INT OF 00
JAZAN SAUDI ARABIA JO / EWO: 10-01525-0004 9