ANCHORAGE ZONE DESIGN (as per CIRIA guide-1)

(A) Prestress on Simple Beam Section:

1650
P1 kN/m^2

D=
(D-h) 1000

V M
Pk
y
h
P2 kN/m^2
Pkv

Simple Beam Section Properties:


Area of girder section, A = 1.65 m^2
Moment of Inertia, I = 0.138 m^4
Section Modulus, Zt = Zb = 0.275 m^3

Tendon Pk x1 y1 x2 y2 Emergence angle, q Pkv


1 13560 0 690 1750 690 0.0000 0
2 5584 0 340 1750 340 0.0000 0
2A 5584 0 340 1750 340 0.0000 0
4 0 0 690 1750 690 0.0000 0

Case Tendon Active Pk Pkv h (D - h) e =(D/2-h)


1 2 5584 0 0.340 0.660 0.160
2 2 & 2A 11168 0 0.340 0.660 0.160
3 2 & 2A & 1 24728 0 0.532 0.468 -0.032 P1 13560 e1 0.69
4 - 0 0 0 1.000 0.500
5 - 0 0 0 1.000 0.500
6 - 0 0 0 1.000 0.500
7 - 0 0 0 1.000 0.500
ANCHORAGE ZONE DESIGN (as per CIRIA guide-1)

P1 P2 P3 Moment due to Net Shear due to Net


Case Dist. from bottom (y)
kN/m^2 kN/m^2 kN/m^2 Pressure Anchor Moment Pressure Anchor Shear
1 130 135 6633 5788 89 0 89 1332 0 1332
1 260 135 6633 4944 339 0 339 2483 0 2483
1 390 135 6633 4099 726 -279 447 3453 -5584 -2131
1 520 135 6633 3254 1228 -1005 223 4242 -5584 -1342
1 650 135 6633 2410 1821 -1731 90 4849 -5584 -735
1 780 135 6633 1565 2481 -2457 24 5275 -5584 -309
1 910 135 6633 720 3185 -3183 2 5520 -5584 -64
1 1000 0 0 0 0 0 0 0 0 0
1 1130 0 0 0 0 0 0 0 0 0
1 1260 0 0 0 0 0 0 0 0 0
1 1390 0 0 0 0 0 0 0 0 0
1 1520 0 0 0 0 0 0 0 0 0
1 1650 0 0 0 0 0 0 0 0 0
1 1780 0 0 0 0 0 0 0 0 0
1 1910 0 0 0 0 0 0 0 0 0
1 2040 0 0 0 0 0 0 0 0 0
1 2170 0 0 0 0 0 0 0 0 0
1 2300 0 0 0 0 0 0 0 0 0
1 2430 0 0 0 0 0 0 0 0 0
1 2560 0 0 0 0 0 0 0 0 0
2 130 271 13266 11577 177 0 177 2664 0 2664
2 260 271 13266 9887 677 0 677 4966 0 4966
2 390 271 13266 8198 1453 -558 894 6906 -11168 -4262
2 520 271 13266 6509 2457 -2010 447 8483 -11168 -2685
2 650 271 13266 4819 3643 -3462 181 9698 -11168 -1470
2 780 271 13266 3130 4963 -4914 49 10551 -11168 -617
2 910 271 13266 1440 6370 -6366 4 11041 -11168 -127
2 1000 0 0 0 0 0 0 0 0 0
2 1130 0 0 0 0 0 0 0 0 0
2 1260 0 0 0 0 0 0 0 0 0
2 1390 0 0 0 0 0 0 0 0 0
2 1520 0 0 0 0 0 0 0 0 0
2 1650 0 0 0 0 0 0 0 0 0
2 1780 0 0 0 0 0 0 0 0 0
2 1910 0 0 0 0 0 0 0 0 0
2 2040 0 0 0 0 0 0 0 0 0
2 2170 0 0 0 0 0 0 0 0 0
2 2300 0 0 0 0 0 0 0 0 0
2 2430 0 0 0 0 0 0 0 0 0
2 2560 0 0 0 0 0 0 0 0 0
3 130 17858 12116 12862 172 0 172 2679 0 2679
3 260 17858 12116 13609 703 0 703 5518 0 5518
3 390 17858 12116 14355 1614 -558 1056 8517 -11168 -2651
3 520 17858 12116 15102 2925 -2010 915 11676 -11168 508
3 650 17858 12116 15848 4657 -3462 1195 14996 -11168 3828
3 780 17858 12116 16594 6831 -6134 696 18475 -24728 -6253
3 910 17858 12116 17341 9467 -9349 118 22115 -24728 -2613
3 1000 0 0 0 0 0 0 0 0 0
3 1130 0 0 0 0 0 0 0 0 0
3 1260 0 0 0 0 0 0 0 0 0
3 1390 0 0 0 0 0 0 0 0 0
3 1520 0 0 0 0 0 0 0 0 0
3 1650 0 0 0 0 0 0 0 0 0
3 1780 0 0 0 0 0 0 0 0 0
3 1910 0 0 0 0 0 0 0 0 0
3 2040 0 0 0 0 0 0 0 0 0
3 2170 0 0 0 0 0 0 0 0 0
3 2300 0 0 0 0 0 0 0 0 0
3 2430 0 0 0 0 0 0 0 0 0
3 2560 0 0 0 0 0 0 0 0 0

Maximum Moment (+ve / clockwise) = 1195 kN-m


Maximum Moment (-ve / anti-clockwise) = 0 kN-m
Maximum Shear (+ve) = 5518 kN
Maximum Shear (-ve) = -6253 kN

Reinforcement required to resist moment = 5493 mm^2


ANCHORAGE ZONE DESIGN (as per CIRIA guide-1)

Calculation of reinforcement for Clockwise moment:


Moment = 1195 kN-m sst = 300 Mpa (crack control, Table-12.2, IRC-112)
Lever Arm = 0.5 m
Reinforcement required = 7964 mm^2
Provided reinforcement = 16 mm dia. 10 leg @ 125 c/c over 500 mm
and 0 mm dia. 2 leg @ 150 c/c over 500 mm
Provided reinforcement = 8042 mm^2 OKAY

Calculation of reinforcement for Anti-Clockwise moment:


Moment = 0 kN-m sst = 280 Mpa (crack control, Table-12.2, IRC-112)
Lever Arm = 0.5 m
Reinforcement required = 0 mm^2
Provided reinforcement = 16 mm dia. 10 leg @ 200 c/c over 500 mm
and 0 mm dia. 2 leg @ 500 c/c over 500 mm
Provided reinforcement = 5027 mm^2 OKAY
ANCHORAGE ZONE DESIGN (as per CIRIA guide-1)

Check for Shear Stress:


Maximum Shear = 6253 kN
Shear stress = 3.79 MPa

Permissible maximum shear stress = 0.75 √Fck = 4.750 MPa


Shear - friction reinforcement (cl. 5.8.4.1 AASHTO LRFD)
Vni = Vu / f = 6948 kN
m= 1.4
Fy = 415
Required area of shear friction reinf., Avf = Vni / (m.Fy) = 11958 mm^2
Provided reinf. = 13069 mm^2 OKAY

500 500

Y16 - 10L @ 200c/c Y16 - 10L @ 125c/c


Y0 - 2L @ 500c/c