Você está na página 1de 6

AxTraxNG

v27.6.1.6
System Release Notes
1. General
 Product Name: AxTraxNG™ Server / AxTraxNG™ Client
 Release Software Version Number: 27.6.1.6: Full Release Version – with Immediate BOM Update
(this version to ship with all latest product shipments)
 Date of Release: 12 March 2019
 The installer for this version is available from the Download Center of the Rosslare website.
 Previous Software Release Version Number: 27.5.7.16 (15 Jan 2018)
 Product Summary: Setup includes AxTraxNG™ Server/Client and AxTraxNG™ Server Monitor, Rosslare ViTrax™ and
prerequisite redistributables

Release Overview
Following the previous release of AxTraxNG V 27.5.7.16 (15 January 2019), this release of AxTraxNG v27.6.1.6 is the newest
major release version of the v27.6.x.x and aligns all of the latest bug fixes and system optimization of all major cases encountered
since the last release. This optimized system has undergone automated testing and live site optimization in systems with hundreds
of control panels.
Biometric Fingerprint Management – Integration – RosslareBio™ 8000 Series: We have added integration to two new fingerprint
and RFID terminals and an enrollment station, making it easier than ever to add fingerprint level security to your systems.
Support for the DR-U955BT – Triple Technology RF- USB Desktop Enrollment Station: This USB credential enrollment station
is used to enroll Rosslare BLE-ID, UHF, and smart card CSN to the system.
An Easy Way to deploy User Dual Authentication – This is an essential module that supports our new readers and lets the system
admin deploy dual factor authentication (Fingerprint+Card, BLE-ID+Card, UHF-ID+BLE-ID, PIN + Card). This new feature can
be selected on a reader-by-reader basis for any Rosslare reader and for any two credentials.
Credential-Type – Distinction In-System – Support for all types of credentials: The ability to have a type assigned to credentials:
Card, BLE, UHF, NFC, Fingerprint, License plate, and PIN code. In a security environment where many different types of readers
are deployed within systems, the system operator will need to know the event logs and the reports by credential type.
Supports Hikvision LPR unique conversion table of alphanumeric license plate for car parking applications when using a very
specific LPR camera from Hikvision. The new server is able to integrate the LPR function into a Wiegand ID, and deploy the LPR
to any user as a credential type. The license plate may be enrolled by data entry via the client interface or live on LPR camera
directly to the system and added to any access user.
The release of AxTraxNG is the newest version that optimizes the full series of control panels sold during 2018 it is the most up-
to-date alignment of all the control panel hardware.
We recommend this for system-wide updates for systems with AC-825IP, including updating the firmware of all the panels in the
system. We recommend this version for all new installations.
Supported Hardware Products:

“825-Panel”
AC-825IP (networked control panel built into ME-1515 enclosure)
AC-825IP-PCBA (control panel only)
R-805, S-805, D-805, P-805
1
“A-Panels” (Rosslare Legacy Networked Access Controllers)
AC-215, AC-215IP
AC-225, AC-225IP (MD-D02, MD-IO84 expansions for AC-225x)
AC-425, AC-425IP (MD-D04, MD-IO84 expansions for AC-425x)
“B-Panels”
AC-215-B (RS-485 bus panel built in to ME-1015 enclosure)
AC-215IP-B (networked panel built in to ME-1015 enclosure)
AC-215-DIN (RS-485 bus panel DIN cover – no enclosure)
AC-215IP-DIN (networked panel DIN cover – no enclosure)
AC-225-B (RS-485 bus panel built in to ME-1015 enclosure)
AC-225IP-B (networked panel built in to ME-1015 enclosure)
AC-225-DIN (RS-485 bus panel DIN cover – no enclosure)
AC-225IP-DIN (networked panel DIN Cover – no enclosure)
MD-D02B (2-Reader 4-input 4-output expansion for AC-225xB)
MD-IO84B (8 Input 4-output expansion for AC-225xB)
AC-425-B (RS-485 bus panel built in to ME-1015 enclosure)
AC-425IP-B (networked panel built in to ME-1015 enclosure)
AC-425-DIN (RS-485 bus panel DIN cover – no enclosure)
AC-425IP-DIN (networked panel DIN cover – no enclosure)
MD-D04B (4-reader 4-input 4-output expansion for AC-425xB)
MD-IO84B (8-input 4-output expansion for AC-425xB)
RosslareBio 8000 Series Fingerprint Terminals (Concurrent Release)
AY-B8520 – Indoor networked optical fingerprint with 125 KHz (EM) RFID card reader
AY-B8550 – Indoor networked optical fingerprint with 13.56 MHz (MHz FARE) RFID card reader
AY-B8620 – Outdoor networked optical fingerprint with 125 KHz (EM) RFID card reader
AY-B8650 – Outdoor networked optical fingerprint with 13.56 MHz (MIFARE) RFID card reader
DR-B8000 – USB 2.0 fingerprint enrollment scanner and desktop reader
Rosslare UHF-SMART series DR-U955BT USB Enrollment Station (Concurrent Release)
DR-U955BT – Desktop enrollment station for UHF, BLE-ID and 13.56 MHz CSN

2. List of Documentation – Manuals / Datasheets


Here is the list of the NEW documents that are available with this release:
(previously released products documents are not included in the release notes)
All the documents have been uploaded are available from our Download Center.
Product Manuals
 AxTraxNG™ 27.6.1.6 Software Installation and User Manual Version – dated 11 March 2019.
 The manual is updated with integrated biometric features.
 See Page 60 for adding biometric terminals
 See Page. 155 for fingerprint enrollment
 The manual updated for multi-credential type support
 The manual updated with dual factor authentication setup
 See Page 57 For adding biometric terminals
Product Data Sheets
 AxTraxNG™ 27.6.1.6 Data Sheet

3. Summary of Major Features /Functionality Added


Biometric Fingerprint Management – Integration – RosslareBio™ 8000 Series
 Including Multi-PC Client Enrollment – for large scale DR-B8000 user registration
 10 Finger Hand Map for Enrolment management interface – per user
 Adding IP Based Biometric Readers (Tree View – Biometric Networks)
 Connecting the Wiegand of the biometric reader to the controller
 Logically associating access groups to readers in the network

2
 Automatically synchronizes relevant templates only to the readers in associated access groups
 Support for the DR-U955BT – Triple Technology RF- USB Desktop Enrollment Station
 Simply connect the USB and enroll directly into any user’s credential list
 Supports BLE-ID / UHF / CSN SMART™ credentials
 Now you can enroll on all three if you add this you get 3 types of RF in one compact unit fully integrated into the
AxTraxNG
 User Dual Authentication
 Easily select any reader to be a dual-factor authentication for HIGH SECURITY and GREAT USER EXPERIENCE
 Users will need to provide any combination of any ID in their credentials list.
 Ability to add a user characteristic for immunity for any user – this user will be immune from dual factor authentication
and may present any one credential
 By having to present a second factor for authentication, system access is constrained to those who possess two factors
(prevents use of found or stolen cards/tags).
 This supports two sessions of User Dual factor authentication per reader
 Credential Type – Distinction In-System – Support for all types of credentials
 The ability to have a Type assigned to credentials: Card, BLE, UHF, NFC, Fingerprint, License plate, PIN code
 This will let the operator see the type in the event log
 Reports may be generated by Credential Type
 Supports Hikvision LPR unique conversion table of alphanumeric license plate;
 The ability to set a unique conversion table from alphanumeric license plate to a Wiegand format
 The ability to enroll license plate to a user (as part of its credentials list)
 Hikvision – DS-2CD4A26FWD-IZS (firmware version 5.45)

4. Issues Resolved (since previous release v27.5.7.16)


This is a chronological list showing earliest to latest completions in AxTraxNG 27.6.1. 6
(detailed for TS and Internal & External – Stakeholders)
 Fixed:
 "Reader Type" in "Add Users and Cards" window doesn't change after setting a default reader type
 [Hikvision Integration] Recording does not stop if pop-up is not selected
 [ViTrax integration] Cannot play recorded video
 License to be reactivated when upgrading AxTraxNG version
 Last day report issue 2 days report
 [Hikvision integration] No video is playing when DVR is being used
 Legacy panels Event ID 20001 shows error
 Reader form – License plate and Biometric terminal can be select simultaneously
 Upgrading AxTraxNG 27.6.0.0 to 27.6.1.0 forces "Clear DB"
 [Downloads] Downloads stuck in DB
 [FW update] After FW update need panel enabling
 Server monitor auto start after install
 Filter Configuration mode trigger for non-responsive panels
 AxTraxNG Server service stops when multiple networks not available
 Adding a 'Clear’ button on DR-U955BT enrollment screen
 "Single Operation Mode" should set as "Card or PIN" when setting a reader's Dual Authentication Mode
 Wiegand 40 PCSC Bits" card's Facility code and card number are not shown in events
 Download 'Duress code' not correct
 Absent version verification for x805
 [Report] Absent details in user credential for Attendance report
 Manual door operation randomly works in Legacy panels
 PIN code unknown for access logged events
 [AxTraxNG] Adding user to the system take more than 10 sec.
 Legacy panel reset to default values after FW update
 AxTraxNG slow communication when using MD-14U
 Hikvision LPR: Events shows Wiegand card number instead of license plate on Access Denied
3
 After adding license file, need manual restart for a AxTraxNG Service
 Updated:
 Update French (Switzerland) translation
 Show credential type on access events
 Updated to search for older license file and renaming it to newer license file for backward compatibility

5. Known Issues
 [Localization] Alarm Handler screen
 [Bio] Updating reader mapped to terminal always reset terminal with full download
 [AC-825] Received packets are handled wrongly by AC-825
 [AxTraxNG Upgrading] After upgrade from v27.5.x.x 825 Network Status is "Disconnected"
 [Dual Authentication] [Legacy] internal RAM error on user forced
 Snapshot pop-up does not show from some cameras connected to ViTrax
 ViTrax™ pop-up video stream might show few seconds of delay before displaying

6. Miscellaneous
 It is very important to make sure that the boot loaders that are in the control panels and expansions are matched with the
version of the control panels so that the firmware update process is successful.
 Boot loaders for the control panels and expansions are not public information for this Release Notes and are only known by
Global Tech Support Group (TSG) and Rosslare Manufacturing teams.

7. Languages Supported
 Arabic  Japanese
 Chinese, Simplified  Portuguese
 Dutch  Russian
 English  Serbian
 French  Slovenian
 Greek  Spanish
 Hebrew  Swedish
 Italian  Turkish

4
8. Firmware Versions for 27.6.1.6 – System Release
Software Version Panel Model Firmware New
Firmware Version Embedded Release
AC825 AC825v02.08.15.hex Yes New
D805 x805v03.52.hex Yes New
P805 x805v03.52.hex Yes New
S805 x805v03.52.hex Yes New
R805 x805v03.52.hex Yes New
AC425B ac425v05_01_07 Yes New
MDD04B mdd04v02_00(Rev B) Yes Current
AC425A ac425v05_01_07 Yes New
MDD04A mdd04v00_04 Yes Current
AxTraxNG V27.6.1.6 AC225B ac225v05_01_07 Yes New
MDD02B mdd02v02_00(Rev B) Yes Current
MDIO84B md-io84v02_00(Rev B) Yes Current
AC225A ac225v05_01_07 Yes New

MDD02A mdd02v00_13 Yes Current


MDIO84A io225v00-08 Yes Current
AC215IPB/AC215B ac215Bv05_01_07 Yes New
AC215IPA ac215Bv05_01_07 Yes New
AC215A ac215v04_08_03 Yes Current
AYB8520 V78 No New
BIO8000 V1.0.0.0 AYB8620 V78 No New
Supported
AYB8550 V76 No New
Firmware
AYB8650 V76 No New
DR-B8000 (Anviz U Bio) TBA No New
CS-HCT Hardware
DR-U955BT DR-U995-V_01_03 No
Configuration Tool
 Compatible ViTrax version – Product version 2.5.8, Module version 2.5.8
 Hikvision SDK version – 5.3.2.15
 Dahua SDK version 3.4.8.27787
 Compatible Rosslare ViTrax™ LPR – 1.9
 Compatible Rosslare AxTime™ software version 27.0.0.1 (Beta)

9. Supported Microsoft Windows OS + Minimum Requirements


 Windows 7
 Windows 8
 Windows 10
 Windows Server
Minimum PC Requirements
Intel i5 or equivalent
500 GB Hard Disk Space
4 GB RAM
10/100 Ethernet Port
Mouse
Keyboard
Display

5
Contact Information
United States and Canada Latin America Asia Pacific, Middle East, Africa
Rosslare Security Products, Inc. Rosslare Latin America Rosslare Enterprises Ltd.
Southlake, TX, USA Buenos Aires, Argentina Kowloon Bay, Hong Kong
Toll Free: +1-866-632-1101 Tel: +54-11-4001-3104 Tel: +852-2795-5630
Local: +1-817-305-0006 support.la@rosslaresecurity.com Fax: +852-2795-1508
Fax: +1-817-305-0069 support.apac@rosslaresecurity.com
support.na@rosslaresecurity.com China
Rosslare Electronics (Shenzhen) Ltd. India
Europe Shenzhen, China Rosslare Electronics India Pvt Ltd.
Rosslare Israel Ltd. Tel: +86-755-8610-6842 Tel/Fax: +91-20-40147830
Rosh HaAyin, Israel Fax: +86-755-8610-6101 Mobile: +91-9975768824
Tel: +972-3-938-6838 support.cn@rosslaresecurity.com sales.in@rosslaresecurity.com
Fax: +972-3-938-6830
support.eu@rosslaresecurity.com

CERT
ISO 9001
ISO 14001

Você também pode gostar