Você está na página 1de 1

Chapter 2 Page 16 of 20

Figure 2–9: DMS sensor cable (5m) (TTSS Part No: B930460)

DMS Series
93+5
-0
CABLE SCREEN TO BE FOLDED BACK ONTO CABLE
DURING BACKPOTTING.
AFTER BACKPOTTING FOLD SCREEN BACK DOWN BU
OVER BACKPOTTING WITH A 6mm OVERLAP AT THE A WT
END OF THE CABLE JACKET AS SHOWN. SCN
SOLDER SCREEN TO THE TERMINATION RING AT 5mm RD
FROM THE END OF THE RING AND TRIM OFF EXCESS BRAID. B WT
PIP COVER THE LENGTH OF SCREEN WITH ELECTRICAL SCN
SCREENING TAPE (REF.RS264-9275) PRIOR TO OVERMOULDING. YL
6 7 C WT
5 8 SCN
14 + BU
4 13 15 9 TSS S GN (MAIN SCREEN)
3 12 16 10 930460 - BK
2 11 GN
1 D WT
SCN
6 BK
SOLDER BUCKET VIEW 5
OF CONNECTOR POLYURETHANE E WT
MHDG-16-CCP-UT OVERMOULDING SCN
32+5
© Teledyne TSS Ltd

EPOXY OR
0 BACKPOT F WT
'A' SCN
SCREEN
TERMINATION
RING 6 6

20 70 10 5
5m ± 100mm OVERALL ( STANDARD LENGTH )

NOTES:
WIRING SCHEDULE:
1. THE CABLE SCREEN TO BE CONNECTED TO PIN 16 VIA A WIRE PLUS
IMPULSE PIN WIRE COLOUR/PAIR DMS - FUNCTION RS 232 RS 422 360° CONNECTION TO THE BACK OF THE CONNECTOR AS SHOWN AT 'A'
2. LABEL EACH TWISTED PAIR AS SHOWN USING HEATSHRUNK SLEEVES
1 BLUE POWER +
2 BLACK POWER - 3. FIT PREPRINTED IDENT SLEEVE 400mm ± 50mm FROM LEFT END.
3 BU - A CHANNEL B TxA PRIMARY COMMS FROM SENSOR Tx TxA 4. ONLY ONE CABLE IDENT SLEEVE TO BE FITTED PER CABLE ASSEMBLY.
4 WT - A CHANNEL B TxB PRIMARY COMMS FROM SENSOR N/A TxB
5. ONLY 'TSS' AND CABLE No. TO BE IMPRINTED ON CABLE IDENT.
5 RD - B CHANNEL B RxA PRIMARY COMMS TO SENSOR Rx RxA
6 WT - B CHANNEL B RxB PRIMARY COMMS TO SENSOR Common RxB 6. ATTACH A PIECE OF GREEN 24/0.2 WIRE TO BRAID & FIT 'S' IDENT
7 YL - C CHANNEL A TxA REMOTE REPEATER LINK FROM SENSOR N/A TxA TO FORM THE MAIN CABLE SCREEN.
8 WT - C CHANNEL A TxB REMOTE REPEATER LINK FROM SENSOR N/A TxB
DPN 402225 Issue 1.5

9 GN - D CHANNEL A RxA REMOTE REPEATER LINK TO SENSOR N/A RxA


10 WT - D CHANNEL A RxB REMOTE REPEATER LINK TO SENSOR N/A RxB
11 BK - E HEADING INPUT Rx RxA
12 WT - E GROUND CONNECTION FOR DMS Common RxB
13 OR - F GPS INPUT Rx RxA
14 WT - F GROUND CONNECTION FOR DMS Common RxB
** 15 N/C
** 16 SCREEN CONNECT TO CABLE SCREEN