Operating Manual and Spare Parts List

Accessories
Filter Cartridge Lifetime Computer
B - Timer

January 2010 1st Edition, Rev. 0 Chg. 2 MNL-0444


© Bauer Compressors, Inc.
BAUER Compressors, Inc. Phone: (757) 855-6006
1328 Azalea Garden Road Fax: (757) 855-6224
Norfolk, Virginia 23502-1944 www.bauercomp.com
Filter Cartridge Lifetime Computer
This information is believed to be accurate by Bauer Compressors, Inc., as of its date of publication, but
Bauer offers NO WARRANTY regarding the accuracy, or continuing accuracy, of the information set
forth herein. Bauer shall not be liable for inaccuracies in, or consequences resulting from, your use of this
information. All information supplied is in connection with sales of Bauer’s products, and is thus subject
to Bauer’s standard terms and conditions of sale. Bauer reserves the right to change this information and
has no obligation to update these materials. Bauer Compressors, Inc.reserves to itself all rights to this
publication. Bauer’s customers have no right to reproduce, rewrite, modify, license or permit anyone
else’s use of this information, without the express written permission of Bauer Compressors, Inc.

^ WARNING
This Instruction Manual contains safety information and instructions.
You must read, understand and follow all safety precautions and instructions.

Editons, Revisions, and Changes


• An Edition is the original or a complete rewriting of the entire manual.
• A Revision occurs whenever a complete section or appendix is rewritten or added.
• A Change occurs when individual pages, drawings or tables are changed.

1st Edition; May 31, 2007

Rev. Chg. Date Notes Auth.


0 1 Dec. 18, 2008 Update from BKM Manual CLA
0 2 Jan. 1, 2010 Update from BKM SS

Page i 1st Edition, Rev. 0 Chg. 2


Filter Cartridge Lifetime Computer
for Filter Systems P21 P31 P41

Introduction Mounting
Read the operating instructions carefully before operating the Mount the B-Timer with the supplied clamp in the center of the
unit. (Applicable for units from version 300.301.811 up). filter housing, on P41 filter system at the separator housing. It
has to have contact to the housing with both straps of the back
The settings in the setup menu are essential plate. Make sure not to touch other mounting clamps of the
for the correct indication of the filter capacity. filter. Should the B-Timer have to be re-mounted, e.g. when
Without correct settings, the B-Timer can be changing the filter housing, ensure that the temperature pad on
used as an hourmeter, only! the back plate is not damaged.
Make sure that the pressure maintaining
valve of the compressor is adjusted to 150 bar
(factory setting) and is working properly to
ensure correct indication of the filter capacity and com­
pressor operation recognition.

Description
The B-Timer (Fig. 1) is a self-activating mini-computer that
counts the operating hours of the compressor and calculates the
saturation of the filter cartridge from time, temperature, car­
tridge type, and delivery rate of the compressor. It displays oper­
ating hours, cartridge lifetime, and all maintenance due for the
compressor. The B-Timer does neither need external power nor
any other connection to the pressure system. It is simply fas­
tened to the filter housing which has to be monitored, by means
of a clamp, and is therefore the ideal filter control device for all
mobile compressor units, especially for portable petrol or diesel
driven scuba diving models. In addition, the B-Timer can be
mounted easily to any unit as an upgrade device.

Authorized use
This unit is to be used exclusively as operating status monitoring
device and does not release the user from additional surveillance
and testing of the breathing air quality of the filter system ac­
cording to national standards (e.g. EN 12021). With the B-
Timer, this is not possible!
The B-Timer may only be used with the filter systems specified
above. The respective filter cartridge numbers are stored in the
software. Other use is strictly prohibited. The manufacturer and
the supplier void all responsibility for risk, damage or injury re­
sulting from failure to follow these instructions.
Observe the operating limits of the unit: Fig. 1 B-Timer
Operating temperature range 0° C to +50 °C,
Storage temperature -20° C bis +70 °C
Protection class IP65 (Protection against contact with wire, dust,
and jet of water
Vibration $3g in operation
max. 95% humidity, not condensating
01/2010

1
Function
The B-Timer display shows the following functions:
• Operating hours of the compressor unit The flashing h-sym­
bol shows that compressor operation has been detected.
2
• Cartridge lifetime in % by means of four segments in the car­ 1
tridge symbol.
4
• Flashing last segment and change from operating hours in­ 3
dication to cartridge part no. if capacity is equal or less than
20% of the original lifetime. 5
• Indication of compressor maintenance due by means of
letter symbols and operating hours.
A = 500 hours or 1 year
B = 1000 hours or 2 years
C = 2000 hours or 4 years 6 7

• Battery symbol indicating that the lithium battery is low and


has to be changed. All data are stored and will not be
lost when changing battery.
The B-Timer is operated using the mode select and the enter
keys.
1 Key symbol (maintenance due)
2 Letter symbol (maintenance type)
3 Low battery symbol
4 Cartridge saturation indicator
5 Operating hours or cartridge number
6 Mode select key
7 Enter key
Fig. 2 Display

Error indication
If the temperature sensor in the unit should be defective, an
error message “Error 1” or “Error 2” is shown at the display
(Fig. 3). In this case the unit should not be used but sent to the
factory or the nearest BAUER representative for repair.

Fig. 3
Battery change
The battery (1, Fig. 4) is merely inserted into the holder. To
change the battery remove plug (2) and pull out battery. Make
sure to use the same type battery (BAUER part no. 82743).

Fig. 4 Battery

2
Operation
The B-Timer is activated when starting the
compressor. Compressor operation is indi­
cated by the flashing “h” symbol.

To switch on the B-Timer press one of the keys on the display.


Main menue will be displayed (Fig. 5). Fig. 5
If no key is pressed within 1 minute, the in­
dication will return to the main menue. After
2 minutes the B-Timer is switched off, if no
compressor operation is detected.

Function Display
To display the desired function, press the se­ Fig. 6
lect key ().

Press  key. Remaining filter capacity is shown, Fig. 6)

Fig. 7
Press  key again. Remaining operating hours to service interval
A (500 hours or annually) are shown (Fig. 7).

Press  key again. Remaining operating hours to service interval


B (1000 hours or annually) are shown (Fig. 8).
Fig. 8

Press  key again. Remaining operating hours to service interval


C (2000 hours or biennially) are shown (Fig. 9).

Fig. 9
01/2010

3
Press  key. Filter cartrige number is shown (Filter symbol flash­
ing, Fig. 10).
Press  key again. Display returns to the main menue.

Reset
The filter capacity must not be reset unless a
new filter cartridge has been fitted!
Fig. 10
To reset the filter capacity or the A, B, and C maintenance inter­
vals, press  key for more than 5 seconds from the respective
maintenance interval display (Fig. 11).

Setup
To enter the setup for the different functions of the B-Timer
press the  and  keys on the display simultaneously for more
than 5 seconds from the cartridge number display (Fig. 10).
Filter symbol starts flashing (Fig. 12) indicating the setup mode. Fig. 11
Under setup A the filter cartridge number is set. To change car­
tridge type, press  key for 3 seconds, the number starts flash­
ing. Press the  key to select the correct number, press  key to
accept the new setting.

Numbers beginning with 999 require a


special adjustment:

Press  key for 3 seconds. Press the  key to select 999000, the
last 0 starts flashing. Press the  key to select the correct
number, then press  key: the second 0 will start flashing, pro­
Fig. 12
ceed as above and finally adjust the 3rd 0 accordingly.
Pressing the  key, display changes to setup B for the delivery
setting (in ltrs/min). Filter symbol starts flashing (Fig. 13). To
change delivery, press  key for 3 seconds, the 1st digit starts
flashing. Press the  key to select the correct number, press 
key to accept the new setting. Repeat procedure for the other
two digits
Pressing the  key again, display changes to setup C for the
pressure range setting. Filter symbol starts flashing (Fig. 14). To
change pressure, press  key for 3 seconds. Press the  key to
select the correct pressure (200, 300 or 200/300), press  key Fig. 13
to accept the new setting.
After finishing setup and fitting a new car­
tridge, the filter capacity has absolutely to be
reset, see “Reset” above.

Pressing the  key again, display changes to the menue for ad­
justing the operating hours. Press  key for 2 seconds, the last
digit will start flashing. Press the  key to select the correct
number, then press  key etc., until all digits are set. Then pres­
sing the  key twice will lead back to the main menue, Pressing
the the  key and the  key gives the possibility to readjust the Fig. 14
hours again, if required.