Você está na página 1de 54

CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

CÁLCULO DE INTENSIDADES EN LA ESTACION SALLIQUE

INFORMACION PLUVIOMETRICA

PRECIPITACIONES (mm)
Máxima en 24 Horas

ESTACION: SALLIQUE LAT.: 05°39'32'' DEPTO: CAJAMARCA


LONG.: 79°18'45'' PROV: JAEN
ALT.: 1789
CATEGORIA: "CO" DIST.: SALLIQUE
m.s.n.m.

Pmax
AÑO ENERO FEBRERO MARZO ABRIL MAYO JUNIO JULIO AGOSTO SEPTIEMBRE OCTUBRE NOVIEMBRE DICIEMBRE anual
(mm)
2002 19.6 26.0 29.4 41.4 15.8 4.2 3.8 0.0 4.6 22.0 19.7 10.0 41.4
2003 10.8 17.8 23.0 12.6 11.2 10.6 5.4 0.0 9.4 3.8 9.6 10.5 23.0
2004 7.0 4.5 17.4 17.8 12.2 5.6 3.2 0.0 3.8 23.3 17.2 18.2 23.3
2005 5.0 15.6 36.0 20.2 3.4 2.2 0.0 0.0 14.0 11.0 8.1 27.6 36.0
2006 14.5 42.9 36.2 51.2 6.0 17.8 6.4 1.4 5.5 13.8 20.0 33.6 51.2
2007 28.2 23.8 53.0 19.0 8.8 15.8 1.2 5.8 2.5 24.8 18.4 13.0 53.0
2008 14.4 36.2 30.4 22.4 5.2 9.4 10.4 2.8 2.3 30.8 23.4 0.0 36.2
2009 24.4 16.0 48.7 16.0 11.2 3.0 0.6 4.6 10.5 17.4 14.8 18.6 48.7
2010 15.6 27.0 36.0 15.4 6.9 5.0 6.2 9.5 7.4 19.4 9.0 20.4 36.0
2011 11.7 16.8 12.5 36.8 4.5 16.2 6.4 1.8 11.4 8.8 23.8 10.4 36.8
2012 25.7 25.7 14.0 13.9 7.0 2.8 0.3 3.0 0.4 31.6 23.5 12.0 31.6
2013 9.9 6.6 13.2 2.8 13.8 2.5 20.8 2.2 2.0 20.0 0.2 6.8 20.8
P.max. Mes 28.2 42.9 53.0 51.2 15.8 17.8 20.8 9.5 14.0 31.6 23.8 33.6 53.0

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS ANUALES

60.0

50.0
Pmax.en 24h Anuales (mm)

40.0

30.0

20.0

10.0

0.0
2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014

AÑOS DE LA ESTACION SALLIQUE

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS MENSUALES

PRECIPITACIONES MAX24H MENSUALES


60.0

50.0
Pmax.en 24h Mensuales (mm)

40.0

30.0

20.0

10.0

0.0
2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
AÑOS DE LA ESTACION SALLIQUE

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 F(z) |F(z)-P(x)|
(mm) (mm)
2002 1 41.4 20.8 0.07692 246.49000 3.03495 -1.79177 0.03658 0.04034
2003 2 23 23.0 0.15385 182.25000 3.13549 -1.44548 0.07416 0.07968
2004 3 23.3 23.3 0.23077 174.24000 3.14845 -1.40084 0.08063 0.15014
2005 4 36 31.6 0.30769 24.01000 3.45316 -0.35135 0.36266 0.05497
2006 5 51.2 36.0 0.38462 0.25000 3.58352 0.09766 0.53890 0.15428
2007 6 53 36.0 0.46154 0.25000 3.58352 0.09766 0.53890 0.07736
2008 7 36.2 36.2 0.53846 0.09000 3.58906 0.11674 0.54647 0.00801
2009 8 48.7 36.8 0.61538 0.09000 3.60550 0.17336 0.56882 0.04657
2010 9 36 41.4 0.69231 24.01000 3.72328 0.57904 0.71872 0.02641
2011 10 36.8 48.7 0.76923 148.84000 3.88568 1.13839 0.87252 0.10329
2012 11 31.6 51.2 0.84615 216.09000 3.93574 1.31082 0.90504 0.05889
2013 12 20.8 53.0 0.92308 272.25000 3.97029 1.42983 0.92362 0.00054
SUMA 438.0 1288.86000

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 y F(Y) |F(z)-P(x)|
(mm) (mm)
2002 1 41.4 20.8 0.07692 246.49000 -1.28259 0.02716 0.04976
2003 2 23 23.0 0.15385 182.25000 -1.02202 0.06211 0.09173
2004 3 23.3 23.3 0.23077 174.24000 -0.98649 0.06844 0.16233
2005 4 36 31.6 0.30769 24.01000 -0.00343 0.36662 0.05892
2006 5 51.2 36.0 0.38462 0.25000 0.51770 0.55107 0.16646
2007 6 53 36.0 0.46154 0.25000 0.51770 0.55107 0.08953
2008 7 36.2 36.2 0.53846 0.09000 0.54139 0.55881 0.02035
2009 8 48.7 36.8 0.61538 0.09000 0.61246 0.58157 0.03381
2010 9 36 41.4 0.69231 24.01000 1.15728 0.73027 0.03796
2011 10 36.8 48.7 0.76923 148.84000 2.02189 0.87599 0.10676
2012 11 31.6 51.2 0.84615 216.09000 2.31799 0.90622 0.06007
2013 12 20.8 53.0 0.92308 272.25000 2.53119 0.92352 0.00044
SUMA 438.0 1288.86000

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO

TIEMPOS DE RETORNO CON DISTRIBUCION GUMBELL

TR

10 0.9 2.2504 50.6290


25 0.96 3.1985 58.6345
50 0.98 3.9019 64.5734
100 0.99 4.6001 70.4684
200 0.995 5.2958 76.3420

DISTRIBUCION GUMBEL
80.0000

75.0000

70.0000
Precipitacion(mm)

DISTRIBUCION GUMBEL
65.0000

60.0000

55.0000

50.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO CON DISTRIBUCION LOG - NORMAL 2 PARAMETROS

TR Z

10 0.9 1.2816 3.9272 50.76682


25 0.96 1.7507 4.0634 58.17458
50 0.98 2.0537 4.1514 63.52527
100 0.99 2.3263 4.2306 68.75727
200 0.995 2.5758 4.3030 73.92236

DIST. LOG NORMAL 2 PARAMETROS


80.00000

75.00000

70.00000
Precipitacion(mm)

65.00000

60.00000 DIST. LOG NORMAL 2


PARAMETROS

55.00000

50.00000

45.00000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

COMPARACION ENTRE TIEMPOS DE RETORNO SEGÚN DISTRIBUCIONES

80.0000

75.0000

70.0000
Precipitacion(mm)

65.0000
DISTRIBUCION GUMBEL

60.0000
DISTRIBUCION LOG NORMAL 2
PARAMETROS
55.0000

50.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

CALCULO DE INTENSIDADES

PRECIPITACIONES MAX24H SEGÚN TR

DISTRIBUCION GUMBELL

DISTRIBUCION GUMBEL DISTRIBUCION GUMBEL(OMM)


Pmax24h,10 años 50.62903 Pmax24h,10 años 56.70451
Pmax24h,25 años 58.63448 Pmax24h,25 años 65.67062
Pmax24h,50 años 64.57339 Pmax24h,50 años 72.32219
Pmax24h,100 años 70.46844 Pmax24h,100 años 78.92465

DISTRIBUCCION LOG NROMAL 2 PARAMETROS

DIST.LOG NORMAL 2 PARAMETROS DIST.LOG NORMAL 2 PARAMETROS(OMM)


Pmax24h,10 años 50.76682 Pmax24h,10 años 56.85884
Pmax24h,25 años 58.17458 Pmax24h,25 años 65.15553
Pmax24h,50 años 63.52527 Pmax24h,50 años 71.14830
Pmax24h,100 años 68.75727 Pmax24h,100 años 77.00814

CALCULO DEL TIEMPO DE CONCENTRACION

COTA DE
TRAMO LONGITUD(KM) COTA DE "D"(m) DESNIVEL (M)
PUNTO(m)
D-a 27.9495 3289.8 1107.1 2182.7
D-b 28.0937 3229.7 1107.1 2122.6
D-c 25.7836 3124.2 1107.1 2017.1

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

METODO ROWE

TRAMO tc(horas) tc(min)


D-a 2.2900 137.3986
D-b 2.3285 139.7115
D-c 2.1506 129.0372

METODO KIRPICH

TRAMO tc(horas) tc(min)


D-a 2.2977 137.8632
D-b 2.3364 140.1839
D-c 2.1579 129.4735

TIEMPO DE CONCENTRACION

tc(h) 2.336
tc(m) 140.1839

TABLA DE PRECIPITACIONES CON TIEMPO DE RETORNOS

DISTRIBUCION
TR GUMBELL LOG NORMAL
10 50.6290 50.7668
25 58.6345 58.1746
50 64.5734 63.5253
100 70.4684 68.7573
200 76.3420 73.9224

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

INTENSIDADES SEGÚN METODO SCC

INTENSIDADES SEGÚN METODO BELL


PRECIPITACIONES MAX24H SEGÚN EL TIEMPO DE RETORNO

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TABLA DE INTENSIDADES SEGÚN DISTRIBUCIONES

CALCULO DE CAUDALES (m3/s) SEGUN METODO BELL

TR
DISTRIBUCION 10 25 50 100
GUMBELL 4.10959734 4.89757868 5.49366355 6.08974842
LOG NORMAL 4.12078162 4.91090744 5.50861456 6.10632167

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

CALCULO DE INTENSIDADES EN LA ESTACION PUCARA

INFORMACION PLUVIOMETRICA

PRECIPITACIONES (mm)
Máxima en 24 Horas

ESTACION: PUCARA LAT.: 06°02'30'' DEPTO: CAJAMARCA


LONG.: 79°08'02'' PROV: JAEN
CATEGORIA: "PLU" ALT.: 1789 m.s.n.m. DIST.: PUCARA

Pmax anual
AÑO ENERO FEBRERO MARZO ABRIL MAYO JUNIO JULIO AGOSTO SEPTIEMBRE OCTUBRE NOVIEMBRE DICIEMBRE
(mm)
1995 2.7 10.6 10.6 20.1 4.0 0.5 10.3 0.6 2.5 10.0 20.2 23.6 23.6
1996 9.5 10.4 40.7 22.1 4.5 10.3 0.0 1.3 10.3 20.7 20.7 11.8 40.7
1997 10.4 12.0 5.7 11.7 4.4 3.6 4.0 1.4 2.7 7.5 10.1 2.6 12.0
1998 17.2 50.4 30.2 30.5 20.4 7.9 0.0 5.3 60.1 40.8 30.3 11.8 60.1
1999 37.6 32.0 20.6 10.9 28.2 7.1 2.1 0.7 20.6 6.5 26.5 30.4 37.6
2000 20.5 70.5 10.1 35.9 14.1 10.2 1.8 4.6 20.5 2.6 10.4 12.7 70.5
2001 50.6 55.8 50.0 11.0 40.3 2.1 5.1 0.0 20.9 50.6 32.8 14.9 55.8
2002 19.6 8.3 14.6 30.2 18.4 4.5 10.1 0.0 1.3 40.6 17.8 11.4 40.6
2003 11.3 24.3 30.2 10.2 10.6 10.5 2.2 2.5 10.1 61.3 30.1 20.9 61.3
2004 10.7 20.0 10.9 50.1 10.4 2.4 7.9 0.0 31.4 20.4 28.3 40.1 50.1
2005 4.0 50.2 40.2 20.9 9.1 3.2 0.1 10.3 11.6 12.0 10.3 22.7 50.2
2007 47.2 10.2 44.0 21.8 16.5 1.1 3.1 7.8 5.3 45.6 60.7 26.4 60.7
2008 35.3 30.6 27.7 20.9 15.4 9.5 3.3 11.6 4.0 40.2 52.5 19.2 52.5
2009 53.1 17.7 28.9 25.3 3.5 2.8 3.1 8.1 2.5 39.7 11.7 20.4 53.1
2010 7.1 38.0 45.1 12.5 8.2 3.6 0.3 2.2 7.1 42.6 9.2 27.6 45.1
2011 20.6 23.4 25.4 30.4 15.8 0.6 3.3 0.8 9.2 31.8 22.0 23.1 31.8
2012 11.9 21.0 30.4 39.8 12.6 1.7 0.8 0.5 1.0 28.3 27.6 24.7 39.8
2013 15.0 12.7 28.2 6.1 47.5 1.3 1.5 13.9 2.4 20.4 28.0 14.0 47.5
P.max. Mes 53.1 70.5 50.0 50.1 47.5 10.5 10.3 13.9 60.1 61.3 60.7 40.1 70.5

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS ANUALES

80.0

70.0
Pmax.en 24h Anuales (mm)

60.0

50.0

40.0

30.0

20.0

10.0

0.0
1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014

AÑOS DE LA ESTACION PUCARA

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS MENSUALES

PRECIPITACIONES MAX24H MENSUALES


80.0

70.0

60.0
Pmax.en 24h Mensuales (mm)

50.0

40.0

30.0

20.0

10.0

0.0
1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009
AÑOS DE LA ESTACION PUCARA

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 F(z) |F(z)-P(x)|
(mm) (mm)
1995 1 23.6 12.0 0.05263 1174.96605 2.48491 -4.30382 0.00001 0.05262
1996 2 40.7 23.6 0.10526 514.28160 3.16125 -2.07135 0.01916 0.08610
1997 3 12 31.8 0.15789 209.60605 3.45947 -1.08698 0.13852 0.01937
1998 4 60.1 37.6 0.21053 75.30383 3.62700 -0.53396 0.29668 0.08616
1999 5 37.6 39.8 0.26316 41.96160 3.68387 -0.34627 0.36457 0.10141
2000 6 70.5 40.6 0.31579 32.23716 3.70377 -0.28058 0.38952 0.07373
2001 7 55.8 40.7 0.36842 31.11160 3.70623 -0.27246 0.39263 0.02421
2002 8 40.6 45.1 0.42105 1.38716 3.80888 0.06638 0.52646 0.10541
2003 9 61.3 47.5 0.47368 1.49383 3.86073 0.23752 0.59387 0.12019
2004 10 50.1 50.1 0.52632 14.60938 3.91402 0.41343 0.66035 0.13404
2005 11 50.2 50.2 0.57895 15.38383 3.91602 0.42001 0.66276 0.08381
2007 12 60.7 52.5 0.63158 38.71605 3.96081 0.56788 0.71494 0.08336
2008 13 52.5 53.1 0.68421 46.54272 3.97218 0.60539 0.72754 0.04333
2009 14 53.1 55.8 0.73684 90.67272 4.02177 0.76910 0.77908 0.04224
2010 15 45.1 60.1 0.78947 191.05383 4.09601 1.01414 0.84474 0.05527
2011 16 31.8 60.7 0.84211 208.00049 4.10594 1.04693 0.85243 0.01033
2012 17 39.8 61.3 0.89474 225.66716 4.11578 1.07940 0.85979 0.03494
2013 18 47.5 70.5 0.94737 586.71605 4.25561 1.54096 0.93834 0.00903
SUMA 833.0 3499.71111

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

TAMAÑO NIVELES DE
DE SIGNIFICANCIA
MUESTRA 0.05 0.01
5 0.560 0.670
10 0.410 0.490
12 0.382 0.486
15 0.340 0.400
20 0.290 0.360
25 0.270 0.320
30 0.240 0.290
35 0.230 0.270
40 0.210 0.250
45 0.200 0.240
50 0.190 0.630
>50 1.36/()^1/2 1.63/()^1/2

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 y F(Y) |F(z)-P(x)|
(mm) (mm)
1995 1 23.6 12.0 0.05263 1174.96605 -2.48593 0.00001 0.05263
1996 2 40.7 23.6 0.10526 514.28160 -1.44943 0.01411 0.09115
1997 3 12 31.8 0.15789 209.60605 -0.71672 0.12903 0.02887
1998 4 60.1 37.6 0.21053 75.30383 -0.19847 0.29537 0.08484
1999 5 37.6 39.8 0.26316 41.96160 -0.00189 0.36718 0.10403
2000 6 70.5 40.6 0.31579 32.23716 0.06959 0.39346 0.07767
2001 7 55.8 40.7 0.36842 31.11160 0.07853 0.39674 0.02832
2002 8 40.6 45.1 0.42105 1.38716 0.47168 0.53582 0.11477
2003 9 61.3 47.5 0.47368 1.49383 0.68613 0.60440 0.13072
2004 10 50.1 50.1 0.52632 14.60938 0.91845 0.67090 0.14458
2005 11 50.2 50.2 0.57895 15.38383 0.92739 0.67329 0.09434
2007 12 60.7 52.5 0.63158 38.71605 1.13290 0.72463 0.09305
2008 13 52.5 53.1 0.68421 46.54272 1.18652 0.73691 0.05270
2009 14 53.1 55.8 0.73684 90.67272 1.42777 0.78675 0.04991
2010 15 45.1 60.1 0.78947 191.05383 1.81199 0.84931 0.05984
2011 16 31.8 60.7 0.84211 208.00049 1.86561 0.85658 0.01448
2012 17 39.8 61.3 0.89474 225.66716 1.91922 0.86353 0.03120
2013 18 47.5 70.5 0.94737 586.71605 2.74127 0.93755 0.00982
SUMA 833.0 3499.71111

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO

TIEMPOS DE RETORNO CON DISTRIBUCION GUMBELL

TR

10 0.9 2.2504 65.0060


25 0.96 3.1985 75.6174
50 0.98 3.9019 83.4895
100 0.99 4.6001 91.3035
200 0.995 5.2958 99.0890

DISTRIBUCION GUMBEL
105.0000

95.0000
Precipitacion(mm)

85.0000

75.0000

65.0000

55.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO CON DISTRIBUCION LOG - NORMAL 2 PARAMETROS

TR Z

10 0.9 1.2816 4.1770 65.17157


25 0.96 1.7507 4.3191 75.12473
50 0.98 2.0537 4.4110 82.34883
100 0.99 2.3263 4.4935 89.43833
200 0.995 2.5758 4.5691 96.46025

DIST. LOG NORMAL 2 PARAMETROS


105.00000

95.00000
Precipitacion(mm)

85.00000

75.00000
DIST. LOG NORMAL 2
PARAMETROS
65.00000

55.00000

45.00000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

COMPARACION ENTRE TIEMPOS DE RETORNO SEGÚN DISTRIBUCIONES

105.0000

95.0000

85.0000
Precipitacion(mm)

75.0000 DISTRIBUCION GUMBEL

DISTRIBUCION LOG NORMAL 2


65.0000 PARAMETROS

55.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

CALCULO DE INTENSIDADES

PRECIPITACIONES MAX24H SEGÚN TR

DISTRIBUCION GUMBELL

DISTRIBUCION GUMBEL DISTRIBUCION GUMBEL(OMM)


Pmax24h,10 años 65.00604 Pmax24h,10 años 72.80677
Pmax24h,25 años 75.61740 Pmax24h,25 años 84.69149
Pmax24h,50 años 83.48951 Pmax24h,50 años 93.50825
Pmax24h,100 años 91.30350 Pmax24h,100 años 102.25992

DISTRIBUCCION LOG NROMAL 2 PARAMETROS

DIST.LOG NORMAL 2 PARAMETROS DIST.LOG NORMAL 2 PARAMETROS(OMM)


Pmax24h,10 años 65.17157 Pmax24h,10 años 72.99216
Pmax24h,25 años 75.12473 Pmax24h,25 años 84.13970
Pmax24h,50 años 82.34883 Pmax24h,50 años 92.23069
Pmax24h,100 años 89.43833 Pmax24h,100 años 100.17093

CALCULO DEL TIEMPO DE CONCENTRACION

COTA DE
TRAMO LONGITUD(KM) COTA DE "D"(m) DESNIVEL (M)
PUNTO(m)
D-a 27.9495 3289.8 1107.1 2182.7
D-b 28.0937 3229.7 1107.1 2122.6
D-c 25.7836 3124.2 1107.1 2017.1

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

METODO ROWE

TRAMO tc(horas) tc(min)


D-a 2.2900 137.3986
D-b 2.3285 139.7115
D-c 2.1506 129.0372

METODO KIRPICH

TRAMO tc(horas) tc(min)


D-a 2.2977 137.8632
D-b 2.3364 140.1839
D-c 2.1579 129.4735

TIEMPO DE CONCENTRACION

tc(h) 2.336
tc(m) 140.1839

TABLA DE PRECIPITACIONES CON TIEMPO DE RETORNOS

DISTRIBUCION
TR GUMBELL LOG NORMAL
10 65.0060 65.1716
25 75.6174 75.1247
50 83.4895 82.3488
100 91.3035 89.4383
200 99.0890 96.4602

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

INTENSIDADES SEGÚN METODO SCC

INTENSIDADES SEGÚN METODO BELL

PRECIPITACIONES MAX24H SEGÚN EL TIEMPO DE RETORNO

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TABLA DE INTENSIDADES SEGÚN DISTRIBUCIONES

CALCULO DE CAUDALES SEGUN METODO BELL

TR
DISTRIBUCION 10 25 50 100
GUMBELL 5.27659022 6.2883328 7.05368652 7.81904023
LOG NORMAL 5.29002621 6.30434503 7.07164759 7.83895016

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

CALCULO DE INTENSIDADES EN LA ESTACION COLASAY


`
INFORMACION PLUVIOMETRICA

PRECIPITACIONES (mm)
Máxima en 24 Horas

ESTACION: COLASAY LAT.: 05°58'00'' DEPTO: CAJAMARCA


LONG.: 79°04'00'' PROV: JAEN
ALT.:
CATEGORIA: "PLU" DIST.: COLASAY
1150m.s.n.m.

Pmax anual
AÑO ENERO FEBRERO MARZO ABRIL MAYO JUNIO JULIO AGOSTO SEPTIEMBRE OCTUBRE NOVIEMBRE DICIEMBRE
(mm)
2002 54.7 15.8 10 87.6 3.9 0.3 6.2 3.1 0 5.3 10.8 3.3 87.6
2003 8.4 46.2 19.7 18.9 20.8 1.9 23.0 10.7 25.8 18.2 48.7 37.9 48.7
2004 58.9 30.6 52.8 20.5 74.3 8.5 1.9 5.9 38.6 30.0 6.8 4.3 74.3
2005 S/D 45.7 18.9 27.4 3.1 2.3 4.0 2.2 0.0 15.8 5.1 3.3 45.7
2006 15.7 5.5 17.8 17.9 20.8 6.5 0.2 2.1 12.1 18.3 37.5 19.2 37.5
2007 16.6 18.0 40.2 26.8 16.2 3.5 4.9 7.1 4.8 34.8 35.0 18.4 40.2
2008 28.5 33.0 59.1 14.1 13.5 9.2 6.4 9.5 26.8 24.4 25.3 65.1 65.1
2009 15.9 24.4 55.5 32.7 12.5 7.0 6.3 0.5 4.5 12.0 10.6 13.3 55.5
2010 7.9 12.1 39.2 6.8 21.0 4.3 8.5 2.6 3.9 6.5 54.8 71.1 71.1
2011 19.0 25.3 56.6 30.0 51.8 11.5 0.8 9.3 21.5 33.4 58.8 17.4 58.8
2012 33.7 29.0 13.4 14.7 6.0 16.0 3.8 1.9 7.3 33.3 45.4 15.0 45.4
2013 15.9 26.2 42.9 35.0 42.4 6.8 4.7 13.8 26.2 27.2 40.1 17.4 42.9
P.max. Mes 58.9 46.2 59.1 87.6 74.3 16.0 23.0 13.8 38.6 34.8 58.8 71.1 87.6

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS ANUALES

100.0

90.0

80.0
Pmax.en 24h Anuales (mm)

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0
2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014

AÑOS DE LA ESTACION COLASAY

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS MENSUALES

PRECIPITACIONES MAX24H MENSUALES


100.0

90.0

80.0
Pmax.en 24h Mensuales (mm)

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0
2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
AÑOS DE LA ESTACION COLASAY

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 F(z) |F(z)-P(x)|
(mm) (mm)
2002 1 87.6 37.5 0.07692 344.72111 3.62434 -1.33329 0.09122 0.01429
2003 2 48.7 40.2 0.15385 251.75111 3.69387 -1.07917 0.14026 0.01359
2004 3 74.3 42.9 0.23077 173.36111 3.75887 -0.84157 0.20002 0.03075
2005 4 45.7 45.4 0.30769 113.77778 3.81551 -0.63454 0.26286 0.04483
2006 5 37.5 45.7 0.38462 107.46778 3.82210 -0.61047 0.27078 0.11384
2007 6 40.2 48.7 0.46154 54.26778 3.88568 -0.37807 0.35269 0.10885
2008 7 65.1 55.5 0.53846 0.32111 4.01638 0.09966 0.53969 0.00123
2009 8 55.5 58.8 0.61538 7.47111 4.07414 0.31078 0.62202 0.00663
2010 9 71.1 65.1 0.69231 81.60111 4.17592 0.68281 0.75264 0.06033
2011 10 58.8 71.1 0.76923 226.00111 4.26409 1.00505 0.84256 0.07333
2012 11 45.4 74.3 0.84615 332.45444 4.30811 1.16596 0.87819 0.03203
2013 12 42.9 87.6 0.92308 994.35111 4.47278 1.76785 0.96146 0.03838
SUMA 672.8 2687.54667

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 y F(Y) |F(z)-P(x)|
(mm) (mm)
2002 1 87.6 37.5 0.07692 344.72111 -0.94593 0.07614 0.00078
2003 2 48.7 40.2 0.15385 251.75111 -0.72447 0.12699 0.02686
2004 3 74.3 42.9 0.23077 173.36111 -0.50302 0.19134 0.03943
2005 4 45.7 45.4 0.30769 113.77778 -0.29796 0.25999 0.04770
2006 5 37.5 45.7 0.38462 107.46778 -0.27336 0.26864 0.11597
2007 6 40.2 48.7 0.46154 54.26778 -0.02730 0.35784 0.10370
2008 7 65.1 55.5 0.53846 0.32111 0.53044 0.55525 0.01678
2009 8 55.5 58.8 0.61538 7.47111 0.80111 0.63838 0.02299
2010 9 71.1 65.1 0.69231 81.60111 1.31784 0.76513 0.07282
2011 10 58.8 71.1 0.76923 226.00111 1.80997 0.84903 0.07980
2012 11 45.4 74.3 0.84615 332.45444 2.07243 0.88172 0.03557
2013 12 42.9 87.6 0.92308 994.35111 3.16331 0.95860 0.03552
SUMA 672.8 2687.54667

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO

TIEMPOS DE RETORNO CON DISTRIBUCION GUMBELL

TR

10 0.9 2.2504 76.4694


25 0.96 3.1985 88.0294
50 0.98 3.9019 96.6054
100 0.99 4.6001 105.1180
200 0.995 5.2958 113.5995

DISTRIBUCION GUMBEL
125.0000

115.0000

105.0000
Precipitacion(mm)

DISTRIBUCION GUMBEL
95.0000

85.0000

75.0000

65.0000

55.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO CON DISTRIBUCION LOG - NORMAL 2 PARAMETROS

TR Z

10 0.9 1.2816 4.3397 76.68720


25 0.96 1.7507 4.4681 87.18961
50 0.98 2.0537 4.5510 94.72708
100 0.99 2.3263 4.6256 102.06197
200 0.995 2.5758 4.6938 109.27150

DIST. LOG NORMAL 2 PARAMETROS


115.00000

105.00000

95.00000
Precipitacion(mm)

85.00000

75.00000 DIST. LOG NORMAL 2


PARAMETROS

65.00000

55.00000

45.00000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

COMPARACION ENTRE TIEMPOS DE RETORNO SEGÚN DISTRIBUCIONES

125.0000

115.0000

105.0000
Precipitacion(mm)

95.0000

85.0000 DISTRIBUCION GUMBEL

75.0000 DISTRIBUCION LOG NORMAL 2


PARAMETROS

65.0000

55.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

CALCULO DE INTENSIDADES

PRECIPITACIONES MAX24H SEGÚN TR

DISTRIBUCION GUMBELL

DISTRIBUCION GUMBEL DISTRIBUCION GUMBEL(OMM)


Pmax24h,10 años 76.46936 Pmax24h,10 años 85.64568
Pmax24h,25 años 88.02945 Pmax24h,25 años 98.59298
Pmax24h,50 años 96.60538 Pmax24h,50 años 108.19802
Pmax24h,100 años 105.11799 Pmax24h,100 años 117.73215

DISTRIBUCCION LOG NROMAL 2 PARAMETROS

DIST.LOG NORMAL 2 PARAMETROS DIST.LOG NORMAL 2 PARAMETROS(OMM)


Pmax24h,10 años 76.68720 Pmax24h,10 años 85.88967
Pmax24h,25 años 87.18961 Pmax24h,25 años 97.65236
Pmax24h,50 años 94.72708 Pmax24h,50 años 106.09433
Pmax24h,100 años 102.06197 Pmax24h,100 años 114.30940

CALCULO DEL TIEMPO DE CONCENTRACION

COTA DE
TRAMO LONGITUD(KM) COTA DE "D"(m) DESNIVEL (M)
PUNTO(m)
D-a 27.9495 3289.8 1107.1 2182.7
D-b 28.0937 3229.7 1107.1 2122.6
D-c 25.7836 3124.2 1107.1 2017.1

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

METODO ROWE

TRAMO tc(horas) tc(min)


D-a 2.2900 137.3986
D-b 2.3285 139.7115
D-c 2.1506 129.0372

METODO KIRPICH

TRAMO tc(horas) tc(min)


D-a 2.2977 137.8632
D-b 2.3364 140.1839
D-c 2.1579 129.4735

TIEMPO DE CONCENTRACION

tc(h) 2.336
tc(m) 140.1839

TABLA DE PRECIPITACIONES CON TIEMPO DE RETORNOS


DISTRIBUCION
TR GUMBELL LOG NORMAL
10 76.4694 76.6872
25 88.0294 87.1896
50 96.6054 94.7271
100 105.1180 102.0620
200 113.5995 109.2715

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

INTENSIDADES SEGÚN METODO SCC

INTENSIDADES SEGÚN METODO BELL


PRECIPITACIONES MAX24H SEGÚN EL TIEMPO DE RETORNO

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TABLA DE INTENSIDADES SEGÚN DISTRIBUCIONES

CALCULO DE CAUDALES SEGUN METODO BELL

TR
DISTRIBUCION 10 25 50 100
GUMBELL 6.20707674 7.39723242 8.29755044 9.19786845
LOG NORMAL 6.2247593 7.41830546 8.32118828 9.2240711

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

CALCULO DE INTENSIDADES EN LA ESTACION PORCULLA


INFORMACION PLUVIOMETRICA

PRECIPITACIONES (mm)
Máxima en 24 Horas
ESTACION: PORCULLA LAT.: 05°50'22.7'' DEPTO: PIURA
LONG.: 79°30'20.6'' PROV:HUANCABAMBA
ALT.: 2169
CATEGORIA: "PLU" DIST.: HUARMACA
m.s.n.m.

Pmax anual
AÑO ENERO FEBRERO MARZO ABRIL MAYO JUNIO JULIO AGOSTO SEPTIEMBRE OCTUBRE NOVIEMBRE DICIEMBRE
(mm)
2001 18.4 16.7 16.8 10.5 12.3 1 5 0 5 7.1 18.4 9.6 18.4
2002 8.9 20 20 19.4 11.2 1.8 3.2 0 0.1 10.3 7.2 12.9 20.0
2003 18.5 16.6 11 11 9.2 11.5 4.2 0 1.4 1 7 13.5 18.5
2004 9.8 6.4 6.3 16.7 10.2 0.1 1.1 0 10.2 12.6 6.6 13.6 16.7
2005 6 18.3 20 8.5 1.9 3 0 0 2 5 3.5 14 20.0
2006 18 55.4 49.5 17.1 1.7 1.8 7.8 0 1 0.1 9.9 12.5 55.4
2007 11.1 10.2 15.2 14.1 5 3.5 0.2 1.7 0.3 17.2 10.2 4.3 17.2
2008 55.9 55 117.1 104.3 6.9 3.8 5.3 4 3.4 15.7 15.4 1.6 117.1
2009 52.3 79.9 72.3 8.4 14.6 1.3 0 1.8 0.5 2.5 16.3 9.8 79.9
2010 32.1 158.4 39.3 16.5 3.3 5.3 0.2 1.2 0.4 39.7 5.5 12.2 158.4
2011 18.6 38.5 11.5 30.3 10.8 5.5 2 1.7 7.3 18.2 9.6 19 38.5
2012 22 43.4 32.5 62.5 4.5 0.3 0 0.1 0 8.3 10.6 13.9 62.5
2013 37.3 36.2 26.8 2.2 29.3 0 2.1 0 7.9 13.7 0.2 8.3 37.3
P.max.
Mes 55.9 158.4 117.1 104.3 29.3 11.5 7.8 4.0 10.2 39.7 18.4 19.0 158.4

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS ANUALES

180.0

160.0
Pmax.en 24h Anuales (mm)

140.0

120.0

100.0

80.0

60.0

40.0

20.0

0.0
2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
AÑOS DE LA ESTACION PORCULLA

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

PRECIPITACIONES MAXIMAS EN 24 HORAS MENSUALES

PRECIPITACIONES MAX24H MENSUALES


180.0

160.0

140.0
Pmax.en 24h Mensuales (mm)

120.0

100.0

80.0

60.0

40.0

20.0

0.0
2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
AÑOS DE LA ESTACION PORCULLA

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 F(z) |F(z)-P(x)|
(mm) (mm)
2001 1 18.4 16.7 0.07143 1160.18840 2.81541 -1.09985 0.13570 0.06427
2002 2 20 17.2 0.14286 1126.37686 2.84491 -1.06067 0.14442 0.00156
2003 3 18.5 18.4 0.21429 1047.26917 2.91235 -0.97111 0.16575 0.04854
2004 4 16.7 18.5 0.28571 1040.80686 2.91777 -0.96391 0.16754 0.11817
2005 5 20 20.0 0.35714 946.27225 2.99573 -0.86038 0.19479 0.16235
2006 6 55.4 20.0 0.42857 946.27225 2.99573 -0.86038 0.19479 0.23378
2007 7 17.2 37.3 0.50000 181.21302 3.61899 -0.03270 0.48696 0.01304
2008 8 117.1 38.5 0.57143 150.34533 3.65066 0.00935 0.50373 0.06770
2009 9 79.9 55.4 0.64286 21.51533 4.01458 0.49263 0.68886 0.04601
2010 10 158.4 62.5 0.71429 137.79148 4.13517 0.65277 0.74305 0.02876
2011 11 38.5 79.9 0.78571 849.04994 4.38078 0.97893 0.83619 0.05048
2012 12 62.5 158.4 0.85714 11586.03840 5.06512 1.88773 0.97047 0.11333
2013 13 37.3 117.1 0.92857 4400.79148 4.76303 1.48656 0.93143 0.00286
SUMA 659.9 23593.93077

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ANALISIS DE CONFIABILIDAD: "DISTRIBUCION LOG - NORMAL DE 2 PARAMETROS"

Pmax anual Pmax anual


AÑO m P(x)=m/N+1 y F(Y) |F(z)-P(x)|
(mm) (mm)
2001 1 18.4 16.7 0.07143 1160.18840 -0.40790 0.22231 0.15089
2002 2 20 17.2 0.14286 1126.37686 -0.39345 0.22716 0.08431
2003 3 18.5 18.4 0.21429 1047.26917 -0.35875 0.23894 0.02465
2004 4 16.7 18.5 0.28571 1040.80686 -0.35586 0.23993 0.04578
2005 5 20 20.0 0.35714 946.27225 -0.31249 0.25491 0.10223
2006 6 55.4 20.0 0.42857 946.27225 -0.31249 0.25491 0.17366
2007 7 17.2 37.3 0.50000 181.21302 0.18771 0.43655 0.06345
2008 8 117.1 38.5 0.57143 150.34533 0.22240 0.44906 0.12237
2009 9 79.9 55.4 0.64286 21.51533 0.71104 0.61193 0.03093
2010 10 158.4 62.5 0.71429 137.79148 0.91632 0.67033 0.04396
2011 11 38.5 79.9 0.78571 849.04994 1.41941 0.78517 0.00055
2012 12 62.5 158.4 0.85714 11586.03840 3.68909 0.97532 0.11817
2013 13 37.3 117.1 0.92857 4400.79148 2.49498 0.92081 0.00776
SUMA 659.9 23593.93077

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO

TIEMPOS DE RETORNO CON DISTRIBUCION GUMBELL

TR

10 0.9 2.2504 108.6398


25 0.96 3.1985 141.4334
50 0.98 3.9019 165.7615
100 0.99 4.6001 189.9101
200 0.995 5.2958 213.9705

DISTRIBUCION GUMBEL
225.0000

205.0000

185.0000
Precipitacion(mm)

165.0000 DISTRIBUCION GUMBEL


145.0000

125.0000

105.0000

85.0000

65.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TIEMPOS DE RETORNO CON DISTRIBUCION LOG - NORMAL 2 PARAMETROS

TR Z

10 0.9 1.2816 4.6087 100.34902


25 0.96 1.7507 4.9619 142.86824
50 0.98 2.0537 5.1901 179.49291
100 0.99 2.3263 5.3954 220.39219
200 0.995 2.5758 5.5833 265.94076

DIST. LOG NORMAL 2 PARAMETROS


295.00000

245.00000
Precipitacion(mm)

195.00000

DIST. LOG NORMAL 2


145.00000 PARAMETROS

95.00000

45.00000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

COMPARACION ENTRE TIEMPOS DE RETORNO SEGÚN DISTRIBUCIONES

295.0000

245.0000
Precipitacion(mm)

195.0000

DISTRIBUCION GUMBEL

145.0000 DISTRIBUCION LOG NORMAL 2


PARAMETROS

95.0000

45.0000
5 50 500
TIEMPODE RETORNO (años)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

CALCULO DE INTENSIDADES

DISTRIBUCION GUMBELL

DISTRIBUCION GUMBEL DISTRIBUCION GUMBEL(OMM)


Pmax24h,10 años 108.63979 Pmax24h,10 años 121.67656
Pmax24h,25 años 141.43337 Pmax24h,25 años 158.40538
Pmax24h,50 años 165.76153 Pmax24h,50 años 185.65292
Pmax24h,100 años 189.91005 Pmax24h,100 años 212.69926

DISTRIBUCCION LOG NROMAL 2 PARAMETROS

DIST.LOG NORMAL 2 PARAMETROS DIST.LOG NORMAL 2 PARAMETROS(OMM)


Pmax24h,10 años 100.34902 Pmax24h,10 años 112.39090
Pmax24h,25 años 142.86824 Pmax24h,25 años 160.01242
Pmax24h,50 años 179.49291 Pmax24h,50 años 201.03206
Pmax24h,100 años 220.39219 Pmax24h,100 años 246.83925

CALCULO DEL TIEMPO DE CONCENTRACION

COTA DE
TRAMO LONGITUD(KM) COTA DE "D"(m) DESNIVEL (M)
PUNTO(m)
D-a 27.9495 3289.8 1107.1 2182.7
D-b 28.0937 3229.7 1107.1 2122.6
D-c 25.7836 3124.2 1107.1 2017.1

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

METODO ROWE

TRAMO tc(horas) tc(min)


D-a 2.2900 137.3986
D-b 2.3285 139.7115
D-c 2.1506 129.0372

METODO KIRPICH

TRAMO tc(horas) tc(min)


D-a 2.2977 137.8632
D-b 2.3364 140.1839
D-c 2.1579 129.4735

TIEMPO DE CONCENTRACION

tc(h) 2.336
tc(m) 140.1839

TABLA DE PRECIPITACIONES CON TIEMPO DE RETORNOS

DISTRIBUCION
TR GUMBELL LOG NORMAL
10 108.6398 100.3490
25 141.4334 142.8682
50 165.7615 179.4929
100 189.9101 220.3922
200 213.9705 265.9408

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

INTENSIDADES SEGÚN METODO SCC

INTENSIDADES SEGÚN METODO BELL

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TABLA DE INTENSIDADES SEGÚN DISTRIBUCIONES

CALCULO DE CAUDALES SEGUN METODO BELL

TR
DISTRIBUCION 10 25 50 100
GUMBELL 8.81837494 10.5092255 11.7883045 13.0673836
LOG NORMAL 8.14540683 9.70722129 10.8886883 12.0701553

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

AREAS PARA EL COEFICIENTE DE COBERTURA

AREAS (KM2)
A1 90.1096
A2 76.9584
A3 22.6221

C1 0.9
C2 0.42
C3 0.72

C* 0.68379467

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA HIDROLOGIA

ISOYETAS(CURVAS CADA 2 MM/H)

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

TRABAJO

“CALCULO DEL CAUDAL EN QUEBRADA DEL RIO PIQUIJACA”


FORMULAS EMPLEADAS PARA LOS CALCULOS REALIZADOS

CALCULO DE PRECIPITACIONES PARA TIEMPO DE RETORNO DE 10, 25, 50, 100, Y 200 AÑOS

SEGÚN DISTRIBUCION GUMBELL

1
𝑃(𝑥 < 𝑎) = 1 −
𝑇𝑅

𝑃(𝑥 < 𝑎) = 𝐹𝐺(𝑦)

1
𝐹𝐺(𝑦) = 1 −
𝑇𝑅
−𝑦
𝐹𝐺(𝑦) = 𝑒 −𝑒

𝑦 = −ln⁡(− ln(𝐹𝐺(𝑦)))

𝑥 =𝑦∗𝛼+𝜇

SEGÚN DISTRIBUCION LOG NORMAL 2 PARAMETROS

1
𝑃(𝑥 < 𝑎) = 1 −
𝑇𝑅

𝑃(𝑥 < 𝑎) = 𝐹(𝑧)

1
𝐹(𝑧) = 1 −
𝑇𝑅

𝑦 − 𝜇𝑦
𝑧=
𝜎𝑦

𝑦 = 𝑧 ∗ 𝜎𝑦 + 𝜇𝑦

𝑦 = ln⁡(𝑥)

𝑥 = 𝑒𝑦

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

CALCULO DEL CAUDAL DE QUEBRADA DEL RIO PIQUIJACA SEGÚN EL METODO RACIONAL

𝐶∗𝐼∗𝐴 3
𝑄= 𝑚 /𝑠
360

∆𝑃
𝐼= 𝑚𝑚/ℎ
∆𝑡

TIEMPO DE CONCENTRACION

ROWE
0.385
0.86 ∗ 𝐿3
𝑡𝑐 = ( ) ℎ𝑜𝑟𝑎𝑠
𝐻

𝐻:⁡𝐷𝐸𝑆𝑁𝐼𝑉𝐸𝐿⁡(𝑚)

𝐿:⁡𝐿𝑂𝑁𝑇𝐼𝑇𝑈𝐷⁡𝐷𝐸𝐿⁡𝑇𝑅𝐴𝑀𝑂⁡(𝐾𝑚)

KIRPICH

3.2808 ∗ 𝐿 0.77
𝑡𝑐 = 0.0078 ∗ ( ) 𝑚𝑖𝑛𝑢𝑡𝑜𝑠
𝑆 0.5

𝐿: 𝐿𝑂𝑁𝐺𝐼𝑇𝑈𝐷⁡𝐷𝐸𝐿⁡𝑇𝑅𝐴𝑀𝑂(𝑚)

∆𝐻
𝑆=
𝐿

COEFICIENTE DE COBERTURA

𝐶1 ∗ 𝐴1 + 𝐶2 ∗ 𝐴2 + 𝐶3 ∗ 𝐴3 … + 𝐶𝑛 ∗ 𝐴𝑛
𝐶∗ =
𝐴1 + 𝐴2 + 𝐴3 + ⋯ 𝐴𝑛

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I


CALCULO DE INTENSIDADES Y CAUDAL EN RIO PIQUIJACA

INTENSIDADES

METODO SCC

0.280049 ∗ 𝑃𝑀𝑎𝑥24ℎ,𝑇𝑅
𝐼𝑡,𝑇𝑅 = , 𝑚𝑚/ℎ
𝑡𝑐 0.6

𝑰𝟏𝟎⁡𝑨Ñ𝑶𝑺

𝑰𝟐𝟓⁡𝑨Ñ𝑶𝑺

𝑰𝟓𝟎𝑨Ñ𝑶𝑺

𝑰𝟏𝟎𝟎⁡𝑨Ñ𝑶𝑺

METODO BELL

𝑃𝑡𝑇𝑅
𝐼𝑡𝑇𝑅 = ∗ 60′, 𝑚𝑚/ℎ
𝑡

𝑡=60𝑚𝑖𝑛
𝑃𝑡𝑇𝑅 = (0.21 ∗ ln(𝑇𝑅) + 0.52) ∗ (0.54 ∗ 𝑡 0.25 − 0.25) ∗ 𝑃𝑚𝑎𝑠24ℎ,𝑇𝑅=100𝑎ñ𝑜𝑠

𝑡=60𝑚𝑖𝑛
𝑃𝑚𝑎𝑠24ℎ,𝑇𝑅=100𝑎ñ𝑜𝑠 = 0.3862 ∗ 𝑃𝑚𝑎𝑥24ℎ,𝑇𝑅=10𝑎ñ𝑜𝑠

𝑃𝑡𝑇𝑅=10𝑎ñ𝑜𝑠

𝑃𝑡𝑇𝑅=25⁡𝑎ñ𝑜𝑠

𝑃𝑡𝑇𝑅=50⁡𝑎ñ𝑜𝑠

𝑃𝑡𝑇𝑅=100⁡𝑎ñ𝑜𝑠

ESCUELA PROFESIONAL DE INGENIERIA CIVIL - 2014 I

Você também pode gostar