Você está na página 1de 1

star/delta starting delay ≅ 1s

L
FLOOR A 8 A 8
D
E
5 5 3

exchange ≤ 0,02s
VML 3

DOWNWARD
C 9 9 VML 2

UPWARD
TO CYLINDER
VRFP 2 TO CYLINDER
VRFP
4

star ≤ 1,5s
VP 4 6 1
G VMD VMP
VMD VMP
PAM
EN 81
1
PAM ML
I
H
FLOOR VSMA 10
MAN
7

MOTOR
VML
VMD
VML

A 7 MAN

VMP
MOTOR
6 ML
ENERGIZED 10

NOT ENERGIZED direct


MOTOR - STAR PHASE starting Valve 2” Valve 1”¼ - 1”½

VALVE BLOCK 3010EN


A 5 G
VRFP VMD
VML VSMA VC 3006/B
VP 9
4
C 7
B
VS
3 ML
K
1
SILENCER G
VRP VSMA
E 2
F
VB VR 8 ML
for direct acting
VRF jacks (1:1) F
VR2
PAM800

E A
6
VMP
10 ISP
VRa VR1
auxiliary levelling

4
device

Ma Pmax Pmin OLD C


M MAN
B
star/delta starting
SCC starting

K one way valve VS pilot valve for VB


ISP inspection gauge fitting VSMA manual lowering valve
MAN manometer 1 pressure relief adjustment
ML manual lowering button 2 levelling speed adjustment
OLD full load pressure limit switch (optional) (D-E upward, H-I downward)
Pmax maximum pressure limit switch (optional) 3 deceleration adjustment
Pmin minimum pressure limit switch (optional) (C-D upward, G-H downward)
PAM hand pump (optional) 4 up acceleration adjustment
VB pressure relief valve 5 shut off valve for rupture valve test
VMD down solenoid valve 6 manometer shut-off valve
VML levelling solenoid valve 7 ram pressure adjustment
VMP starting solenoid valve (only for indirect acting jacks)
(star/delta - SCC starting) 8 full speed adjustment
VP pressure valve 9 down speed compensation adjustment
VR ceck valve 10 pressure relief valve adjustment (hand pump)
VR1 non return valve (inlet) C hoistway proximity switch (upward)
VR2 non return valve (outlet) G hoistway proximity switch (downward)
VRF flow regulation valve E motor switching-off
VRFP auxiliary flow regulation valve I VMD switching-off
VRP main non-return valve

VALVE BLOCK “3010EN” data sheet :04.007/B 1/1


hydraulic circuit and working diagram date : 24/03/2003