Escolar Documentos
Profissional Documentos
Cultura Documentos
PAGE NO. 1
****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.90 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= NOV 25, 2018 *
* Time= 11:58:47 *
* *
* USER ID: *
****************************************************
1. STAAD SPACE
INPUT FILE: C:\Users\Hiccup\Desktop\STRUCTURAL DESIGN\JEFFREY CARTAGENA\FINAL DESIGN\STAAD ANALYSIS\CO.. .STD
2. START JOB INFORMATION
3. ENGINEER DATE 19-NOV-18
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 4 4.11 0 0; 7 7.9 0 0; 10 0 0 3.625; 13 4.11 0 3.625; 16 7.9 0 3.625
9. 19 0 0 7.25; 22 4.11 0 7.25; 25 7.9 0 5.75; 30 4.11 4.7 5.75; 31 4.11 7.4 5.75
10. 33 6.775 4.7 5.75; 68 7.9 7.4 5.75; 69 6.775 4.7 3.625; 70 4.11 4.7 8.375
11. 73 0 4.7 8.375; 89 7.9 4.7 3.625; 90 4.11 7.4 0; 91 0 4.7 7.25
12. 92 4.11 4.7 3.625; 93 0 7.4 0; 94 4.11 7.4 3.625; 95 0 7.4 3.625
13. 96 0 4.7 3.625; 97 4.11 4.7 0; 98 7.9 7.4 3.625; 99 0 4.7 0; 100 7.9 7.4 0
14. 101 4.11 4.7 7.25; 102 4.11 7.4 7.25; 103 7.9 4.7 5.75; 104 0 7.4 7.25
15. 105 7.9 4.7 0
16. MEMBER INCIDENCES
17. 1 1 99; 2 99 93; 3 99 97; 4 93 90; 5 4 97; 6 97 90; 7 97 105; 8 90 100
18. 9 7 105; 10 105 100; 11 99 96; 12 93 95; 13 97 92; 14 90 94; 15 105 89
19. 16 100 98; 17 10 96; 18 96 95; 19 96 92; 20 95 94; 21 13 92; 23 92 69
20. 24 94 98; 25 16 89; 27 96 91; 28 95 104; 29 92 30; 30 94 31; 31 89 103
21. 32 98 68; 33 19 91; 35 91 101; 36 104 102; 37 22 101; 41 25 103; 42 103 68
22. 43 30 101; 44 31 102; 45 30 33; 46 31 68; 47 69 89; 48 33 103; 49 69 33
23. 50 73 70; 51 101 70; 52 91 73; 53 89 98; 55 91 104; 56 92 94; 65 101 102
24. START GROUP DEFINITION
25. FLOOR
26. _2F_2W 3 7 11 13 15 19 23 27 29 31 35 43 45 47 TO 49
27. _2F_1W_BAL 35 50 TO 52
28. _RD_2W 4 8 12 14 16 20 24 28 30 32 36 44 46
29. END GROUP DEFINITION
30. DEFINE MATERIAL START
31. ISOTROPIC CONCRETE
32. E 2.17185E+007
33. POISSON 0.17
34. DENSITY 23.5616
35. ALPHA 1E-005
36. DAMP 0.05
37. TYPE CONCRETE
38. STRENGTH FCU 27579
MASS MODEL IS FORMED BY COMBINING ALL "DEAD" AND "LIVE" (IF ANY) REFERENCE LOADTYPES.
************************************************************************************
NO. TYPE FL. LEVEL FL. WT CENTRE OF MASS MASTER JOINT NO.
X Z
************************************************************************************
76. R1 1.0
77. LOAD 1 LOADTYPE SEISMIC TITLE EX
78. UBC LOAD X 1 DEC 1 ACC 0.05
79. PERFORM ANALYSIS
P R O B L E M S T A T I S T I C S
-----------------------------------
1 4.70 OK OK
2 7.40 OK OK
***********************************************************
* *
* X DIRECTION : Ta = 0.328 Tb = 0.587 Tuser = 0.000 *
* T = 0.328, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1294 x 1105.52 = 143.07 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
80. CHANGE
81. LOAD 2 LOADTYPE SEISMIC TITLE EZ
82. UBC LOAD Z 1 DEC 1 ACC 0.05
83. PERFORM ANALYSIS
***********************************************************
* *
* Z DIRECTION : Ta = 0.328 Tb = 0.579 Tuser = 0.000 *
* T = 0.328, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1294 x 1105.52 = 143.07 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
84. CHANGE
85. LOAD 3 LOADTYPE DEAD TITLE DL
86. REFERENCE LOAD
87. R1 1.0
88. LOAD 4 LOADTYPE LIVE REDUCIBLE TITLE LL
89. FLOOR LOAD
90. _2F_2W FLOAD -1.9 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.
************************************************************
************************************************************
180. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2016 Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************