DESIGN OF UNIAXIAL BENDING CIRCULAR COLUMN

INPUT DATA :

1 ) ENTER THE DIA OF COLUMN = 500 mm


2 ) CHARACTERISTIC STRENGTH OF CONCRETE ( f CK ) = 20 N / mm2
3 ) CHARACTERISTIC STRENGTH OF STEEL ( f y ) = 415 N / mm2
4 ) FACTORED LOAD ( Pu ) = 2049 KN
5 ) FACTORED MOMENT 250 KN.m
6 ) HEIGHT OF COLUMN ( H ) = 3.2 m
7 ) CLEAR COVER 40 mm

SOLUTION :
ASSUMING REINFORCEMENTS ON FOUR SIDES
ENTER THE DIA METER OF THE BAR 12 mm

EFFECTIVE COVER ( d' ) = 46 mm


d' / D 0.095

pu / fck .D.D = 0.41


Mu / fck .D.D2 = 0.1

pu / fck = 0.12

CALCULATION OF ASC :
PERCENTAGE OF REINFORCEMENT = 0.24
AREA OF STEEL AT COMPRESSION = 471.24 mm2
NO OF BARS 6

DESIGN OF TIES :
1/4 X MAIN ROD DIA 3 mm
DIA OF TIES 6 mm
SPACING OF TIES 192 mm
500mm

6 NOS OF 12mm DIA ,Fe415 BARS

6mm DIA Fe415 BARS @ 192mm C/C

CLEAR COVER 40mm

CROSS SECTION

6 NOS OF 12mm DIA ,Fe415 BARS

6mm DIA Fe415 BARS @ 192mm C/C

LONGITUDINAL SECTION
d' / D -X
10 250 d' = 46 mm Mu / fck .b.D2
15 415 d' / D = Err:509 D= Err:509
20 500 b = Err:509
25 d' / D - y mu = Err:509
35 d' = 46 mm
45 d' / D = 0.1 mm NO OF BARS = 6
50
55 SPACING OF TIES :
60 16 * DIA 192
65 300
70 500
75
80 6 NOS OF

6mm DIA

CLEAR COVER
6

Fe 415

12mm DIA , Fe415 BARS

Fe415 BARS @ 192mm C/C

40mm