Você está na página 1de 27

System Modeling

AC Network

©2015 ETAP PROPRIETARY & CONFIDENTIAL


ETAP Overview

• One-Line Diagram • Mode Toolbar

• Toolbar Format • System Toolbar

• Dumpster • Study Case Toolbar

• Project View • Message Log

• Project Toolbar

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Select Study Mode

Edit Toolbar
AC Elements
System Manager DC Elements
Instrument
Devices

System
Toolbar

One-Line Diagram Help Line


In Edit Mode Displays the
description for
every entry field.
Message Logger
View the latest
messages related to
ETAP Projects.
It can be expanded
or reduced.

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Mode Toolbar Format

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Analysis Toolbar Format
Analysis toolbars have the following sections:

1. Run the Calculation


2. Stop the Calculation
3. Display Alerts
4. Result Analyzer and Output Reports
5. Display Options
6. Get On-Line Data
7. Get Archived Data

All ETAP analysis toolbars follow this general format.

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Cursor Auto connection
Bus 3W XFMR
Cursor Bus
2W XFMR Voltage Regulator
Open Delta XFMR Cable
Trans. Line
Cable Impedance
Reactor Impedance Converter
Generator
Power Grid Battery PV Array
PV
Wind Turbine Gen Synch. Motor
Motor Static Load
Induction Machine MOV
Lumped Load Capacitor Lumped Load Elementary Diagram
Static Load Harmonic Filter
Panels Composite
Phase Adapter Motor Composite Network
Remote Connector MG Set Fuse
CB
SVC HVDC
SPDT
SPST
Composite Motor Composite Network
UPS VFD
Fuse Contactor
HVCB LVCB Charger
Recloser Ground Switch
Inverter
Overload Heater In-Line Overload Relay
SPST SPDT

Instrumentation Ground Grid

Display Options Schedule Report Manager

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Current Transformer Potential Transformer
Voltmeter Ammeter
Multimeter CSD XFMR
Voltage Relay 27 / 59 Reverse Power Relay
Frequency Relay 81 Solid State Trip Relay
Motor Relay Overcurrent Relay 50/51/67
Overload Heater Multi Function Relay
Taglink

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Run Load Flow Calculation
Auto Run
Stop Calculation
Display Options
Load Flow Alerts
Load Flow Result
Analyzer
Load Flow Report Manager

Get One-Line(RT) Data


Get Archived Data

Load Analyzer
©2015 ETAP PROPRIETARY & CONFIDENTIAL
3-Phase SC IEC Duty Calculation

1-Phase SC IEC Duty Calculation

60909 Unbalanced LG, LL, LLG & 3-Phase

Transient IEC 61363

Short-Circuit Display Options

Short-Circuit Alerts for Buses & PDs

Short-Circuit Report Manager

IEC 363 Plots / Export COMTRADE

Short Circuit Result Analyzer

Stop SC Calculations
©2015 ETAP PROPRIETARY & CONFIDENTIAL
Run Arc Flash

Run Arc Flash 1-Phase

AF Fault Insertion
AF 1-Phase Seq. Of Ops

Create STAR View (TCC)

STAR View manager


Display options
Alert View
Report Manager
AF Result Analyzer
Stop AF Calculation
Get One-Line Data
Get Archived Data
©2015 ETAP PROPRIETARY & CONFIDENTIAL
Create a New Presentation

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Voltage Propagation

©2015 ETAP PROPRIETARY & CONFIDENTIAL


The Remote Connector

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Insert Protective Devices

Hint

Protective Devices can be inserted


Without breaking connection line

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Move From Dumpster
• Elements can be moved from the Dumpster into
the one-line diagram with the same name IDs by
using the following methods:

1. Right-click on the one-line diagram and select


Move From Dumpster

2. Click on Edit on the Menu Bar and select “Move


From”

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Move From Dumpster
• Rules:

• Move From Dumpster can be done only under


“Edit” mode and “Base” revision data

• Deleted Items (element groups) must be


present in Dumpster beforehand

• IDs of the moved elements, along with the


connections, status, and properties are
preserved

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Move From Dumpster

• Move desired Dumpster cell group by selecting from


the Dumpster window

• Move From Dumpster capability also supported inside


Composite Networks

• Both sections of Remote Connector element must be


moved from the dumpster at the same time

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Data Block
• Create a DataBlock for Bus elements to display the following:
-Bus Name (ID) -kW Loading
-Nominal Bus kV -Voltage Drop in kV

©2015 ETAP PROPRIETARY & CONFIDENTIAL


3D Database

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Study Conditions
• Different Operating Requirements

Generator 1 in Voltage Generator 1 in Swing Mode


Control Mode
©2015 ETAP PROPRIETARY & CONFIDENTIAL
Study Conditions
• Different Loading Conditions

Summer Loading Winter Loading

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Study Conditions
• Different Configurations

Configuration Normal Configuration GenOFF


©2015 ETAP PROPRIETARY & CONFIDENTIAL
Study Conditions
• Different Engineering Data

Revision Base Revision Sub2a Mod

©2015 ETAP PROPRIETARY & CONFIDENTIAL


3-D Database
Presentations Configurations
Symbol & CB, Fuse, Switch,
Annotation Load, & Motor
Visibility, Status
Location,
& Size

Properties

Nameplate,
Rating, Loading,
Settings, Dimension, etc.
Base & Revision Data
©2015 ETAP PROPRIETARY & CONFIDENTIAL
Presentations
Symbol &
Annotation
Visibility,
Location,
& Size

 One-Line Diagrams
 Impedance Diagrams
 Relay Diagrams
 Physical Diagrams
 Study Diagrams
©2015 ETAP PROPRIETARY & CONFIDENTIAL
Configurations
CB, Fuse, Switch,
Load, & Motor
Status

©2015 ETAP PROPRIETARY & CONFIDENTIAL


Properties
Properties

Nameplate,
Rating, Loading,
Settings, Dimension, etc.
Base & Revision Data
©2015 ETAP PROPRIETARY & CONFIDENTIAL

Você também pode gostar