Você está na página 1de 3

16D@10" CC 16D@10" CC 16D@10" CC

16D@8" CC
16D@8" CC

16D@8" CC
5'x5' 5'x5' 5'x5'

16D@8" CC
16D@10" CC 16D@10" CC

16D@8" CC
16D@8" CC

16D@8" CC
5'x5' 5'x5'
6'x6'

16D@8" CC
16D@10" CC 16D@10" CC
16D@8" CC

16D@8" CC
16D@8" CC

5'x5' 6'x6' 5'x5'

16D@6" CC
16D@6" CC

16D@10" CC 16D@10" CC

16D@8" CC
16D@8" CC

5'x5' 5'x5'
6.5'x6.5'

16D@8" CC
16D@10" CC 16D@10" CC
16D@7" CC

16D@8" CC
16D@7" CC

5'x5' 5'x5'
6'x6'

Foundation Layout and Reinforcement Details


Reinforcement:
Provide uniform Top and Bottom Reinforcement as below

TOP: 2-16D
Bottom: 2-16D

Plinth Beams Dimension in MM


X

5 4 3 2 1

Excavated soil

To Arch: Verify the Existing


slope profile

First Floor level

Plinth Beam

Min 1500 mm

Min 600 mm
Excavation profile as
per the landscaping
Road Level
min 1.5 m

Gutter for proper


Properly compacted drainage on the
soil fill Grade slab

From Natural slope profile: All Footing bottom shall be minimum 1.5 m from the
From Excavated Slope profile: All footing bottom shall be minimum 1 m
To Arch: verify the soil
slope profile

NOTE: Minimum Footing depth =1.5 m from the existing slope profile for all footing

Section X-X-Excavation profile