Standard
• Standard actuator accepts 24 to 240
Volt DC or AC single phase input,
50 and 60 Hz. Three phase is
optional.
• Separate terminal enclosure isolated
from the electronics and motor
compartment. Only the wiring terminal
is exposed during field installation.
• Standard adjustable torque
switches, from 40 to 100%
of rated torque output.
• Manual override does not require a
declutchable mechanism – always
engaged.
• NEMA 4/4X/6 enclosure rating with
CSA (C-US) and CE.
• Anodized aluminum with epoxy
powder coat to help protect unit in
most aggressive environments.
• Visual mechanical position indicator
for accurate visual reference
of valve position.
• ISO 5211 mounting system with star
drive or bore and key for adaptation to
other quarter-turn valves; minimizes
costs associated with adaptation.
• Permanently lubricated self-locking
gear train helps eliminate the need for
motor brakes.
• Mechanical travel stops designed to
prevent over-travel during hand wheel • Communication modules for most Technical Data
or motor operation. standard communication bus Temperature: Units available for
protocols. Bluetooth® modules allow -40°F to 158°F
• Over temperature motor thermostat. for non-intrusive access to the F02 [-40°C to 70°C]
• Integral speed control independently for configuration, operation and
interrogation via a Bluetooth® Output Torque: up to 17,700 lb. in.
adjustable in opening and
enabled handheld PDA or PC. [2000 Nm]
closing directions.
• Integral local control panel. Voltage: Standard Unit: Universal for –
Optional Controls 24 to 240 VAC, 1 phase 60/50
• Analog control modules offer General Applications hertz and 24 to 240 VDC
4 to 20 mA input/output. Complete Quarter-turn ball, butterfly, or rotary plug Optional Units for:
with additional output relays and valves, dampers, etc. 208 to 240 VAC, 3 phase 60/50 hertz
monitor relay. Alternate 0 to 10 VDC 380 to 480 VAC, 3 phase 60/50 hertz
input/output. 575 VAC, 3 phase 60/50 hertz
BIFFI is either a trademark or registered trademark of Tyco International Services AG or its affiliates in the
Flow Control United States and/or other countries. All other brand names, product names, or trademarks belong to their
respective holders.
AWWA
Unit is tested to, and compliant with
WWA C540.
Material of Construction
Option Modules
Non-Intrusive Operations
PDA Manager
The PDA Manager will transform your The F02 is available with Bluetooth® PDA Manager uses Windows Mobile
common PDA, or dedicated industrial non-intrusive communication for both 2003 for Pocket PC (or later) Operating
PDA, into a strong tool for the complete on-off and modulating operation. Using System, and requires Bluetooth® 1.1
control, set-up and diagnostics of the Bluetooth® communication, it is compliant (or later). All the data
F02 actuators installed in your plant. possible to communicate with the exchanged with the actuator in the field
A user-friendly graphic interface actuator from a distance. In addition, it can be shared with your PC in the office
reproduces the actuator local control is possible to connect to any F02 with through the PC Manager Software.
panel for easy control of the automated the optional Bluetooth®, as long as you
package, offering several tools for are in range.
analyzing actuator status.
PC Manager
PC Manager transforms your PC into a actuator. F02 supports Bluetooth® PC Manager software supports
strong tool for the control, set-up and non-intrusive communication. The Bluetooth® and USB communication
diagnostics of F02 actuators. A user- same graphic interfaces available with (Windows 2000 and XP operating
friendly graphic interface reproduces PDA Manager are used with PC systems).
the actuator local control panel, Manager, and are easily synchronized
offering several tools for analyzing the with the PDA.
BB R
R
G FF EE
C
W
W
W
P
P
N
N M
M
LL
HH
W
W
K
A1
A1
J
A
A
H
H
D
D1
D1
Dimensions (inches)
Weight3
Model A A1 B C D D1 E F G H J K L M N P R1 W2 (lbs)
F063 9.4 11.3 10.7 8.3 4.5 6.3 3.3 4.7 2.7 3.1 2.5 1.3 1.4 2.6 2.7 4.9 6.9 1" NPT 16.5
F125 9.4 11.3 10.7 9.0 4.5 6.3 3.3 4.7 2.7 3.1 2.5 1.3 2.1 3.4 3.4 4.9 6.9 1" NPT 19.8
F250 11.6 13.4 13.1 11.3 5.1 6.9 4.3 6.1 2.7 3.7 3.0 1.3 2.5 3.7 3.6 7.1 9.1 1" NPT 34.2
F500 11.6 13.4 13.1 11.3 5.1 6.9 4.3 6.1 2.7 3.7 3.0 1.3 2.5 3.7 3.6 7.1 9.1 1" NPT 37.5
F1K0 13.4 15.3 13.7 14.3 5.5 7.3 4.3 6.8 2.7 4.1 3.2 1.3 5.5 6.8 6.5 9.5 9.1 1" NPT 57.0
Notes:
1. Space required for cover removal
2. 4 total conduit connections
3. Add 1.1 lbs. for Option Module OM3 Local Interface
Model F2K0
R
R
G F E
W
W
W
W
P
P
N LL M
M C
C
W
W
K
K K
K H
H
B
B
A JJ
H A1
A1
D
D
D1
D1
Dimensions (inches)
Weight3
Model A A1 B C D D1 E F G H J K L M N P R1 W2 (lbs)
F2K0 13.4 15.3 19.9 18.3 5.5 7.3 10.5 6.8 2.7 4.1 3.2 1.3 9.5 10.7 10.4 9.5 9.1 1" NPT 99.2
Notes:
1. Space required for cover removal
2. 4 total conduit connections
3. Add 1.1 lbs. for Option Module OM3 Local Interface
C
C
SS
SS
A
A B
ActuatorBase
Actuator Base
Dimensions (inches)
Standard Bore1 Bolt Circle2 Standard Bore Insert
A B C S
Flange Dia. Holes Flange Dia. Holes Star Drive
Model Dia. Key Depth Code Code Square [mm] depth
F063 1.125 1/4 x 1/4 1.34 F05 1.97 M6 F07 2.76 M8 17 1.34
F125 – – 2.12 F07 2.76 M8 F10 4.02 M10 22 2.12
F250 1.875 1/2 x 3/8 2.12 F10 4.02 M10 F12 4.92 M12 27 2.12
F500 1.875 1/2 x 3/8 2.12 F10 4.02 M10 F12 4.92 M12 27 2.12
F1K0 2.250 1/2 x 3/8 4.80 F10 4.02 M10 F14 5.51 M16 36 1.57
F2K0 2.250 1/2 x 3/8 4.80 F12 4.92 M12 F16 6.50 M20 36 1.57
Notes:
1. Standard bore for the model F125 is 35 mm with 10 mm x 8 mm key.
2. F250 units with serial number before 064519E18030 have 35 mm bore and three bolt circles, F07, F10, and F12. Insert is 22 mm star.
Performance
Output torque is independently adjustable from 40% to 100% in both directions of travel. Adjustments are in increments of 1 from 0 to 9. The default setting is
100%, position 9 on the rotary selector used for configuration.
Output speed is adjustable from 10% to 100% in both directions of travel. Adjustments are in increments of 1 from 0 to 9. The default settings are: 18 seconds
for the F063, F125, F250, AND F500 - 30 seconds for the F1K0 - and 66 seconds for the F2K0. The tolerance is +/- 10% of nominal.
Current Draw
8 12 15 22 30 40 50 60 75 90 8 12 15 22 30 40 50 60 75 90
Notes: 33 53 66 100 132 180 220 264 330 400 Model F2K0
1. A = current draw (Amp) at nominal conditions (output torque 100%)
2. Max current (Amp) at stall conditions – 1.2 x A
3. Current diagrams for VDC supply
Current diagrams for VAC/1-phase supply
4. Power factor for VAC supply – 0.60
Wiring Diagram
General Arrangement with Base Card
Position Sensor
M
Connector L Connector M
Notes:
1) Connection L1-L2 for VDC or VAC single phase motor supply from 24 to 240 volt
Connection L1-L2-L3 for 3-phase motor supply from 208 to 575V
2) Remote commands options
OP OP
34 35 35 +
OP CL CL
35 36 36
CL
36 32 32 –
32
Internal supply 24VDC External supply 24/120VAC External supply 24/120VDC
33
F 063 A 0 W5 00 0
Other Products
ALGA
Supply Pressure: 40 to 150 psig
Output Torques: to 2,300,000 lb. in.
(Higher Torque levels available)
ALGAS
Supply Pressure: 40 to 150 psig
Output Torques: to 698,320 lb. in.
(Higher Torque levels available)
Other Products
Other Products
ICON2000
Torque range of 22 lb. ft. to 1,062 lb. ft.
encompassing 5 models.
Other Products
ELGA-2000
Scotch-yoke reducer for applications
requiring high torques.
Torque range of 831,970 lb. in. to
2,956,150 lb. in.
Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services.
Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES NO
REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO
THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR NATURE, INCLUDING
INCIDENTAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. Patents and Patents Pending in the U.S. and foreign countries. Tyco
reserves the right to change product designs and specifications without notice. All registered trademarks are the property of their respective owners. Printed in the USA.
Copyright © 2009 Tyco Flow Control. All rights reserved. BIFMC-0472 www.tycoflowcontrol.com