Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190228

Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.

Project Name : H&M MINKA Report Date : 19/7/2019


Order Name : H&M MINKA Unit Quantity : 1
AHU No. : UMA - SALA DE VENTAS
EUROVENT
Model Name : DM2-1015 Unit Weight : 738.6 kg Energy Efficiency (2016)
Class :
VRV AHU Model : AHUR60DALJY2
Customer :

AHU Unit Specification


*This symbol is only for DRM internal use.

*Supply Air Volume Flow 9386.00 CFM *Return Air Volume Flow - *Unit Type : DM2
Rate :
4.43 m³/s Rate :- :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.5 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 1530 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame Yes
::Yes Unit Width : 1950 mm
*All C-Channel Base : No Cross Section Air Velocity :1.77
1.77 m/s Unit Length : 3700 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 1350 x 1850 mm
Internal Dim. (HxW) :1350
(Upper) :
*Canopy : No Design outdoor
Internal Dim.
temperature 25.50 °C - mm
(HxW, Upper) :
:
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.19 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.04 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 3.46 W/(m³/s)

Printed on : 7/19/2019 Framework Build : 1.20160.0.0 Page : 1 Page Count : 4


DAIKIN REFRIGERATION MALAYSIA SDN. BHD.
DMAHU TECHNICAL REPORT

Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190228

Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.

Project Name : H&M MINKA Report Date : 19/7/2019


Order Name : H&M MINKA Unit Quantity : 1
AHU No. : UMA - SALA DE VENTAS
EUROVENT
Model Name : DM2-1015 Unit Weight : 738.6 kg Energy Efficiency (2016)
Class :
VRV AHU Model : AHUR60DALJY2
Customer :
(SFPint)

Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2450 1250
Weight kg 363.2 375.4
Depth mm
Weight kg

1 EXTERIOR FILTER

*Model AmAir 300E


::AmAir Type : Flat filter 1.99
Filter Face Velocity ::1.99 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : G4 Pressure Drop : 46.65 Pa

*Frame Sliding
::Sliding Final Pressure Drop 139.96 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 6
: board Drop 93.31 Pa
:
*Quantity (12" x24 ") 0
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend

2 DX COIL (couple with VRV)

GENERAL FIN TUBE


*Coil Model : 1015-E1204-R *Material : Aluminium Material : Copper
*Coil Medium : R410A *Fin Protection : None OD : 9.53 mm
*Rows/Fin per Inch : 4 / 12 Type : Corrugated Thickness : 0.35 mm
Coil Layers : 1 Thickness : 0.11 mm Tube Height : 44
*Circuits per Coil : 88 *Height : 1118 mm Pattern : 25.4 x 22.0
Total Int. Volume : 0.02 m³ *Length : 1609 mm :None
*Moisture Eliminator :None
Face Velocity : 2.46 m/s *Width : 88 mm ME Pressure Drop : 0.00 Pa
Heat Pump Mode : Yes
COOLING HEATING
FRAME / OTHERS AIR SIDE AIR SIDE
*Frame Material : GI EDB / EWB : 25.50 / 22.90 °C EDB / EWB : 15.00 / 10.00 °C
*Drain Pan Material : SSTL 304 LDB / LWB : 12.21 / 11.51 °C LDB / LWB : 34.02 / 17.41 °C
*Header Material : Copper ERH / LRH : 80.4 / 92.3 % ERH / LRH : 52.9 / 17.0 %
*Connection Joint : Brazed Pressure Drop (Wet): 126.25 Pa Pressure Drop : 82.59 Pa
Header Location : Right Pressure Drop (Dry) : 82.59 Pa Mass Flow Rate : 19138.43 kg/h
Drain Pipe Location : Right Mass Flow Rate : 19138.43 kg/h ERH = Entering Air Relative Humidity

Printed on : 7/19/2019 Framework Build : 1.20160.0.0 Page : 2 Page Count : 4


DAIKIN REFRIGERATION MALAYSIA SDN. BHD.
DMAHU TECHNICAL REPORT

Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190228

Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.

Project Name : H&M MINKA Report Date : 19/7/2019


Order Name : H&M MINKA Unit Quantity : 1
AHU No. : UMA - SALA DE VENTAS
EUROVENT
Model Name : DM2-1015 Unit Weight : 738.6 kg Energy Efficiency (2016)
Class :
VRV AHU Model : AHUR60DALJY2
Customer :
LRH = Leaving Air Relative Humidity

VRV KIT REFRIGERANT SIDE REFRIGERANT SIDE


Controller Entering Liquid : 43.00 °C Cond. Temp : 46.00 °C
EKEQMCBA : 0 Saturated Suction : 6.00 °C Subcooling Temp : 3.00 °C
EKEQFCBA : 3 Suction Superheat : 5.00 °C Hotgas Superheat : 5.00 °C
MicroTech III : 1 Flow Rate : 4276.30 kg/h Flow Rate : 2266.78 kg/h
EXV Kit Pressure Drop : 9.39 kPa Pressure Drop : 0.83 kPa
EKEXV 140 : 0 Temperature Drop : 0.33 °C Temperature Drop : 0.03 °C
EKEXV 200 : 0 Capacity / Circuit : 2.07 kW/cc Capacity / Circuit : 1.18 kW/cc
EKEXV 250 : 0 *Total Capacity : 182.10 kW *Total Capacity : 103.71 kW
EKEXV 400 : 0 *Sensible Capacity : 68.62 kW *Sensible Capacity 103.71
: kW
EKEXV 500 : 3
*Suction Pipe Size : 1-1/8"
*Liquid Pipe Size : 5/8"

3 SUPPLY FAN

GENERAL FAN MOTOR


Discharge Arrangement : Front Type : Centrifugal Backward *Motor Type : TEFC Squirrel Cage Induction

Supply Air Volume 9386.00 CFM Brand : Nicotra Gebhardt *Eff Type : IE2 (High eff)
Flow Rate : 4.43 m³/s *Model : RDH450R *Brand : TECO
Altitude : 0.00 m Fan Size : 450 mm *Motor Output Power 7.50
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 575x575 mm Frame Size : 132M
Air Density : 1.20 kg/m³ At Frequency : 60 Hz N Voltage : 380 V
Internal Static
219.56 Pa Max. Frequency : - Hz N Current : 15 A
Pressure :
External Static
622.72 Pa Total Efficiency : 69.3 % Efficiency : 89.5 %
Pressure :
Other Static
20.00 Pa Static Efficiency : 55.0 % Speed : 1770 RPM
Pressure :
Fan System Input
Velocity Pressure : 224.00 Pa 8.69 kW
Power :
*Total Pressure : 1086.28 Pa Duct Velocity : 13.40 m/s Watt / CMH : 0.44
*VPT : No *Speed : 2070 RPM *Electrical Supply : 380V/3Ph/ 60Hz
*VFD : No *Shaft Diameter : 35 mm *Pole :4
*Shaft Power : 6.24 kW *Shaft Diameter : 38 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 6.97 kW *Space Heater : No

Printed on : 7/19/2019 Framework Build : 1.20160.0.0 Page : 3 Page Count : 4


DAIKIN REFRIGERATION MALAYSIA SDN. BHD.
DMAHU TECHNICAL REPORT

Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190228

Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.

Project Name : H&M MINKA Report Date : 19/7/2019


Order Name : H&M MINKA Unit Quantity : 1
AHU No. : UMA - SALA DE VENTAS
EUROVENT
Model Name : DM2-1015 Unit Weight : 738.6 kg Energy Efficiency (2016)
Class :
VRV AHU Model : AHUR60DALJY2
Customer :

*Standby Motor With Specific Fan Power (SFP) : 1.57 kW/(m³/s) *Thermistor : No
No
Heater :
# Design based on wet condition.

# The fan system effect is taken into account in the fan performance.

Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 86 87 88 92 87 83 78 71 93
In-duct Supply Air (Lw) dB 89 95 94 96 94 90 81 73 99
Casing Sound Power Level (LwA) dB N/A 83 81 82 80 76 55 37 84
# The airborne total (dBA) is calculated for range 125Hz till 8kHz

DOOR LOCATION

Door Type : Swing door

No Component Name Location No Component Name Location


1 Supply Fan Right

ACCESSORIES

No Component Name Quantity Type Details

SPECIAL REMARK

No Component Name Remark


For Model 22xx and 25xx, or section size larger than 2250mm for width and length, it will be
1 Unit Model
delivered in SKD/CKD if by sea freight, or depending to delivery method.